NDM2Z SeriesDC Molded Case
Circuit Breaker
2010.07
NDM2Z SeriesDC Molded CaseCircuit Breaker
SummaryApplication
NDM2Z Series DC MCCB030405060708080809
Working ConditionModel and ImplicationMain SpecificationsTripping CurveAccessory CodeWiring CapacityPower ConsumptionTemperature Derating Dimension
NDM2ZB Series DC MCCB19202122232324242425
Model and ImplicationWorking ConditionMain SpecificationsTripping Characteristics Accessory CodeTemperature DeratingPower ConsumptionWiring CapacityWiring MethodDimension
35353637373839404143
Mounting IllustrationAuxiliary ContactAlarm ContactUndervoltage ReleaseShunt ReleaseMechanical InterlockHandle Padlocking DeviceMotor OperatorHandle Operating MechanismInterlock
Accessory
Leading Low-voltage Electrical Component Manufacturer
NDM2Z Series DC Molded Case Circuit Breaker (hereinafter "DC
MCCB") includes NDM2Z type and NDM2ZB type.
NDM2Z type and NDM2ZB type DC MCCBs are suitable for power distribution, circuit and equipment protection in DC circuit, of which rated operational voltage is up to DC250V and rated current is up to 630A, with the function of overload and short circuit protection. Besides that, NDM2ZB type MCCB has short-time short-circuit protection function.
03 04
Altitude: ≤2000mAmbient temperature: -5℃ ~ +40℃The relative humidity of the air does not exceed 50% at the temperature of +40℃. Higher relative humiditymay be permitted at lower temperatures, such as 90% at 20℃. Special measures may be necessary in caseof occasional condensation due to variations in temperature. Resisting the effects by humid air.Resisting the effects by salt mist and oil mist.Resisting the effects by mildew.Installation category III for main circuit, category II if not.Pollution degree: 3Service place without explosive media, gas and dust which are corrosive and conductive.Be mounted from rain nor snow.Users should negotiate with the manufacturer in advance if the working conditions are worse than above.
Model and Implication
No. Implication
MCCB
No code: Direct handle operation
P: Motor operation Z: Rotary handle operation
Please refer to Accessory Code Table
0: Frame only, w/o trip unit (may be used as disconnect switch to connect bus)2: Magnetic only 3: Thermal magnetic
Please refer to Main Specifications Table
No code: Fixed type
P: With extended front termination kits
K: Frame type connection (only for NDM2Z-125 and NDM2Z-250)
JK: Frame type connection only for leading-in terminal
CK: Frame type connection only for leading-out terminal
H: Rear connection
Z1: Rear plug-in connection
Z2: Front plug-in connection
J: With mechanical interlock device
Brand code
Product code
Design code
Utilisation code
Frame size
Operation method
Number of poles
Trip unit
Accessory code
Rated current
Connection type
2, 3
63, 125, 250, 400, 630
NDM2X(B) Series DC Molded Case Circuit Breaker
IEC 60947-1, IEC 60947-2, GB/T 14048.1GB 14048.2.TüV, CE, DIN, CCC.
Standards and Certificates
Working Condition
NDM2Z Series DC MCCB
Z: DC application ZX: Small base DC application (only for frame size of 125A)
11
11
Main Specifications
Tripping Curve
s
Note: Iop -- Tripping current of trip unit top -- Tripping time of trip unit
Type Number
of poles
8002,3
2,3
2,3
2,3
2,3
10, 12.5,16, 20,25, 32,40, 50, 63
16, 20, 25,32, 40, 50,63, 80,100, 125
125, 160, 180, 200, 225, 250
225, 250, 315, 350, 400
400, 500, 630
800
800
800
800
Frame size
(A) Inm
Rated current
(A) In
Rated insulation voltage (V) Ui
Rated operational voltage
(DC V) UeEndurance
Rated ultimate breaking
capacity (kA) Icu/ Time
constant (ms)
Rated operating short-circuit breaking
capacity (kA) Ics/ Time
constant (ms)
05 06
(w/loads)
(w/loads)
(w/loads)
(w/loads)
(w/loads)
(w/o loads)
(w/o loads)
(w/o loads)
(w/o loads)
(w/o loads)
07 08
Accessory Code
Wiring Capacity
Power Consumption
Temperature Derating
Note: Measured under the relative rated current.
(Marine (Marine (Marine (Marine (Marine Derating Coefficient (In)
Type
Type
Direct Heated
Direct Heated
Direct Heated
Indirect Heated
Indirect Heated
Indirect Heated
Indirect Heated
Indirect Heated
Indirect Heated
Total Power Consumption of Three Poles (W)Total Power Consumption of Two Poles (W)Front/Rear Connection
Rear Plug-in Connection
Rear Plug-in Connection
Front Plug-in Connection
Front Plug-in Connection
Front/Rear Connection
Current (A)
Min.Min.
Min.
Min.Min.
Min.
Min.
Max.Max.
Max.Max.
Max. Max.Max.Cable or Cooper Bar
Frame Type
Connection
Code Name
Undervoltage Release, Single Auxiliary Contact and Alarm Contact
Double Auxiliary Contact, Single Auxiliary Contact and Alarm Contact
(not available for NDM2Z-63)
Two Sets Single Auxiliary Contact
Double Auxiliary Contacts and Single Auxiliary Contact
Undervoltage Release and Double Auxiliary Contact
Undervoltage Release and Single Auxiliary Contact
Alarm Contact
Shunt Release and Alarm Contact
Double Auxiliary Contact and Alarm Contact
Undervoltage Release and Alarm Contact
Shunt Release, Single Auxiliary Contact and Alarm Contact
Single Auxiliary Contact and Alarm Contact
No Accessory
Shunt Release
Double Auxiliary Contacts
Single Auxiliary Contact
Undervoltage Release
Shunt Release and Double Auxiliary Contacts
Shunt Release and Single Auxiliary Contact
Shunt Release and Undervoltage Release
Two Sets Double Auxiliary Contacts (No right mounting Double Auxiliary
Contacts for NDM2Z-63.)
Type
Number of Poles
Mounting Position
Application +45℃) Application +50℃) Application +55℃) Application +60℃) Application +65℃)
Note: Only front connection type for NDM2X-125 series DC MCCB.
Dimension
NDM2Z-63 Dimension
Front connection (2P, 3P)
Rear connection (2P, 3P)
Rear plug-in connection (2P, 3P)
Front plug-in connection (2P) X-X, Y-Y are the centre of MCCB
Insulating plate
X-X, Y-Y are the centre of 3P MCCB
Dimensions of plug-in base
X-X, Y-Y are the centre of 3P MCCB
Aperture dimension of the subpanel, rear connection
Aperture dimension of the subpanel, front connection
X-X, Y-Y are the centre of 3P MCCB
Unde
rvol
tage
relea
se
09 10
165
222
M4
NDM2ZX-125 Small Base (2P) Dimension Rear connection (2P, 3P)
Dimension of plug-in base
Rear plug-in connection (2P, 3P)
Front plug-in connection (2P) X-X, Y-Y are the centre of MCCB
X-X, Y-Y are the centre of 3P MCCB
A direction
X-X, Y-Y are the centre of 3P MCCBAperture dimensions of the subpanel, rear connectionFront connection (2P)
NDM2Z-125 Dimension
Front connection (2P, 3P)
Aperture dimensions of the subpanel, front connection
11 12
X-X, Y-Y are the centre of 3P MCCB
Unde
rvolta
ge re
lease
Extended front terminal kits (optional)
NDM2Z-250 Dimension
Front connection (2P, 3P)
Rear connection (2P, 3P)
Rear plug-in connection (2P, 3P)
Front plug-in connection (2P)
X-X, Y-Y are the centre of 3P MCCB
X-X, Y-Y are the centre of MCCB
Dimensions of plug-in baseX-X, Y-Y are the centre of 3P MCCB
Aperture dimensions of the subpanel, rear connection
X-X, Y-Y are the centre of 3P MCCB
Extended front terminal kits (optional)
Unde
rvol
tage
relea
se
13 14
5
5.5
3510 89
58
54 (m
in)
88 (m
ax)
54 (m
in)
54 (m
in)
NDM2Z-400 Dimension
Front plug-in connection (2P) X-X, Y-Y are the centre of MCCB
Rear plug-in connection (2P, 3P) X-X, Y-Y are the centre of 3P MCCB
Dimensions of plug-in base
Front connection (2P, 3P)
Extended front terminal kits (optional)
X-X, Y-Y are the centre of 3P MCCB
Aperture dimensions of the subpanel, front connection
Rear connection (2P, 3P) X-X, Y-Y are the centre of 3P MCCB
Aperture dimensions of the subpanel, rear connection
Unde
rvol
tage
relea
se
15 16
65(m
in)
A direction
NDM2Z-630 Dimension
Front connection (2P, 3P)
Extended front terminal kits (optional)
X-X, Y-Y are the centre of 3P MCCB
Front plug-in connection (2P) X-X, Y-Y are the centre of MCCB
Rear plug-in connection (2P, 3P) X-X, Y-Y are the centre of 3P MCCB
Dimensions of plug-in base
Aperture dimensions of the subpanel, front connection
Rear connection (2P, 3P) X-X, Y-Y are the centre of 3P MCCB
Aperture dimensions of the subpanel, rear connection
Unde
rvol
tage
relea
se
17 18
NDM2ZB Series DC MCCB with Three-stage Protection Function
Model and Implication
Working Condition
19 20
No. Implication
DC MCCB with short-time short-circuit protection
63, 125, 250, 400, 630
No code: Direct handle operation
P: Motor operation Z: Rotary handle operation
Magnetic trip unit + short-time delay trip unit
Thermal magnetic trip unit + short-time delay trip unit
Please refer to Table 3.
MCCB
Altitude: ≤2000m
Ambient temperature: -5℃ ~ +40℃
The relative humidity of the air does not exceed 50% at the temperature of +40℃.Higher relative humidity may be permitted
at lower temperatures, such as 90% at +20℃. Special measures may be necessary in case of occasional condensation due to
variations in temperture.
Resisting the effects by humid air.
Resisting the effects by salt mist and oil mist.
Resisting the effects by mildew.
Installation category III for main circuit, catagory II if not.
Pollution degree: 3.
Service placeut explosive media, gas and dust which are corrosive and conductive.
Be mounted from rain nor snow.
Users should negotiate with the manufacturer in advance if the working conditions are worse than above.
Reverse feeding is not allowed. Insulating test between leading-in terminals is forbidden.
2, 3
12
Please refer to Main Specifications Table.
No code: Fixed type
P: With extended front termination kits
K: Frame type connection (only for NDM2ZB-125 and NDM2ZB-250)
JK: Frame type connection only for leading-in terminal
CK: Frame type connection only for leading-out terminal
H: Rear connection
Z1: Rear plug-in connection
Z2: Front plug-in connection
J: With mechanical interlock device
Brand code
Product code
Design code
Utilisation code
Frame size
Operation method
Number of poles
Trip unit
Accessory code
Rated current
Connection type
Short-time delay12
21 22
Main Specifications
Tripping Characteristics
Tripping Curve
Note:1. Ii can be selected between 12In-20In.2. Is can be selected between 4In-10In.3. t is the delay time added on to provide selective protection. It's not the interrupting time.
Type
Instantaneous tripping current Ii
Type Number
of poles
Frame size
(A) Inm
Rated current
(A) In
Rated insulation voltage (V) Ui
Rated working voltage
(DC V) UeEndurance
(2 poles in series)
(2 poles in series)
(3 poles in series)
(2 poles in series)
(3 poles in series)
(2 poles in series)
75(3 poles in series)
(2 poles in series)
75(3 poles in series)
(3 poles in series)
Rated ultimate breaking
capacity (kA) Icu/ Time
constant (ms)
Rated operating short-circuit breaking
capacity (kA) Ics/ Time
constant (ms)
40, 50, 63
40, 50, 63,80, 100, 125
125, 160, 180, 200, 225, 250
225, 250, 315, 350, 400
400, 500, 630
2,3
2,3
2,3
2,3
2,3
s
Note: Iop -- Tripping current of trip unit top -- Tripping time of trip unit
(w/loads)
(w/loads)
(w/loads)
(w/loads)
(w/loads)
(w/o loads)
(w/o loads)
(w/o loads)
(w/o loads)
(w/o loads)
Tolerance for settingvalue of short-time
short-circuit tripping time
Setting value of short-time short-circuit
tripping time (ms) t
Short-time short-circuittripping current Is
24
Accessory Code
Code Name
TypeNumber
of Poles
Mounting Position
No Accessory
Shunt Release
Double Auxiliary Contacts
Single Auxiliary Contact
Alarm Contact
Single Auxiliary Contact and Alarm Contact
Power Consumption
Wiring Capacity
Type
Min.Min.
Min.
Min.
Min.
Min.Min.
Max.Max.
Max.
Max.
Max.
Max.Max.Cable or Cooper Bar
Frame Type Connection
Temperature Derating
Wiring Method
2 poles wiring
Line
Load Load
Please consult with the manufacturer if other wiring method is adopted.
Load
Line Line
3 poles wiring
Derating Coefficient (In)
Type
Indirect Heated
Indirect Heated
Indirect Heated
Direct Heated
Indirect Heated
Indirect Heated
Indirect Heated
Total Power Consumption of Three Poles (W)
Front/Rear Connection Rear Plug-in Connection Front Plug-in ConnectionCurrent
(A)
(Marine Application +45℃)
(Marine Application +50℃)
(Marine Application +55℃)
(Marine Application +60℃)
(Marine Application +65℃)
23
Note: Measured under the relative rated current.
NDM2ZB-63 Dimension
Dimension
Front connection (2P, 3P)
Aperture dimension of the subpanel, front connection
X-X, Y-Y are the centre of 3P MCCB
Rear plug-in connection (2P, 3P) X-X, Y-Y are the centre of 3P MCCB
Front plug-in connection (2P) X-X, Y-Y are the centre of MCCB
Dimensions of plug-in base
Rear connection (2P, 3P) X-X, Y-Y are the centre of 3P MCCB
Aperture dimension of the subpanel, rear connection
Und
ervo
ltage
re
leas
e
(2P)(3P)
(2P)
A direction
(3P)
(2P)
(2P)
(3P)
(3P)
Insulating plate
2625
165
222
M4
NDM2ZB-125 Dimension
Front connection (2P, 3P)
Aperture dimension of the subpanel, front connection
Insulating plate
Und
ervo
ltage
re
leas
eX-X, Y-Y are the centre of 3P MCCB
Rear connection (2P, 3P) X-X, Y-Y are the centre of 3P MCCB
Rear plug-in connection (2P, 3P) X-X, Y-Y are the centre of 3P MCCB
Front plug-in connection (2P) X-X, Y-Y are the centre of MCCB
Aperture dimension of the subpanel, rear connection
Dimensions of plug-in base
(2P)
(3P)
(2P)
(3P)
(2P)
(2P)
(2P)
(2P)
(3P)
(3P)
A direction
2827
NDM2ZB-250 Dimension
Front connection (2P, 3P) X-X, Y-Y are the centre of 3P MCCB
Rear plug-in connection (2P, 3P) X-X, Y-Y are the centre of 3P MCCB
Front plug-in connection (2P) X-X, Y-Y are the centre of MCCB
Dimensions of plug-in base
Rear connection (2P, 3P) X-X, Y-Y are the centre of 3P MCCB
Aperture dimensions of the subpanel, rear connection
Extended front terminal kits (optional)
Und
ervo
ltage
rele
ase
(2P)
(3P)
(2P)
(2P)
(2P)
(2P)
(3P)
(3P)
A direction
3029
5
5.5
3510 89
59
54(m
in)
54(m
in)
54(m
in)
NDM2ZB-400 Dimension
Front connection (2P, 3P) X-X, Y-Y are the centre of 3P MCCB
Rear plug-in connection (2P, 3P) X-X, Y-Y are the centre of 3P MCCB
Front plug-in connection (2P) X-X, Y-Y are the centre of MCCB
Dimensions of plug-in base
Extended front terminal kits (optional)
Und
ervo
ltage
rele
ase
Aperture dimensions of the subpanel, front connection
(2P)
(3P)
(2P)
(2P)
(2P)
(2P)
(3P)
(3P)
Rear connection (2P, 3P) X-X, Y-Y are the centre of 3P MCCB
Aperture dimensions of the subpanel, rear connection
(2P)
(3P)
A direction
3231
NDM2ZB-630 Dimension
Front connection (2P, 3P)
Extended front terminal kits (optional)
Und
ervo
ltage
rele
ase
X-X, Y-Y are the centre of 3P MCCB
Rear plug-in connection (2P, 3P) X-X, Y-Y are the centre of 3P MCCB
Front plug-in connection (2P) X-X, Y-Y are the centre of MCCB
Dimensions of plug-in base
Rear connection (2P, 3P)
Aperture dimensions of the subpanel, rear connection
X-X, Y-Y are the centre of 3P MCCB
(2P)(3P)
(2P)
(3P)
(2P)
(2P)
(3P)
(3P)
(2P)
A direction
3433
Aperture dimensions of the subpanel, front connection
Accessory
Mounting Illustration
Alarm Contact
Legends
Auxiliary Contact and Its Combination
Specifications of Auxiliary Contact Wiring Schematic of Auxiliary Contact
Current Parameters
Electrical Endurance of Auxiliary Contact
Making and Breaking Capacity of Auxiliary Contact
Alarm Contact and Its Combination
Wiring Schematic of Alarm Contact
MCCB in "OFF" or "ON" position
MCCB in "FREE TRIP" position
The conventional thermal current of alarm contact is 3A, and the rated operational current is 0.3A under the rated working voltage of AC400V.
Alarm contact will not operate when DC MCCB operates normally. Only when a free trip or tripping due to defect occurs, the contacts will alternate. And the alarm contact is reset when DC MCCB is re-latched.
Alarm Contact Ue=220V, Ith=3A
Frame Size
Making BreakingUtilisation Categpry
OperatingFrequency(times/h)
Duration under
CurrentTimes
Making BreakingUtilisation Categpry
OperatingFrequency(times/h)
Duration under
CurrentTimes
Conventional Thermal Current Ith
Rated Current under AC 400V
MCCB in "OFF" or "FREE TRIP" position
Double auxiliary contacts
Single auxiliary contact
MCCB in "ON" position
Right mounting
Single auxiliary contact
Double auxiliary contacts
Alarm contact
Shunt Release
Undervoltage release
Handle
Left mounting
Auxiliary contact
3635
Power Supply
Turned-onloop
Turned-offloop
Undervoltage Release
Mechanical Interlock
Shunt release
Wiring Schematic of Undervoltage Release
Instantaneous Tripping Current and Power Consumption of Shunt Release
Dimension
Instantaneous Tripping Current and Power Consumption of Undervoltage Release
Wiring Schematic of Shunt Release
Power supply
Power supply
Between 35%~70% of rated control voltage, undervoltage
release should operate in security and trip DC MCCB. When
under 35% of rated voltage, it should prevent DC MCCB
from closing. DC MCCB closing is possible only if the power
supply voltage is no less than 85% of rated voltage.
Attention: Only undervoltage release be energized in
advance, DC MCCB can be closed or re-latched. Otherwise,
DC MCCB may be damaged.
Between 70%~110% of rated control voltage, shunt release should trip DC MCCB in security under any operating conditions.
Note: Below shunt controlling loop design is recommended when the power of the controlling loop is DC 24V.KA stands for the relay in DC 24V controlling loop. The current capacity of its contract is 1A.
Control voltage:
Control voltage:
TypeInstantaneous Tripping Current (mA) Power Consumption (W)
Type
Type Note
For
For
For
For
For
For
For
For
For
For
A Switch B Switch
Instantaneous Tripping Current (mA) Power Consumption (W)
3837
NDM2Z-63NDM2ZB-63 2PNDM2Z-125NDM2ZB-125 2P
NDM2ZB-63 3P
NDM2Z-250NDM2ZB-250 2PNDM2Z-400NDM2ZB-400 2PNDM2Z-630NDM2ZB-630 2P
NDM2ZB-400 3P
NDM2ZB-125 3P
NDM2ZB-250 3P
NDM2ZB-630 3P
P1 P2
Power supply
Handle Padlocking DeviceMounting Diagram of MS1 Handle Padlocking Device
Motor Operator
Wiring Schematic
Specifications of CD2 Motor Operator
Matching DC MCCB Type Tripping Current
(A)
Motor Power
(W)
Endurance
(times)
Operation Device
Height (mm) H
Power
Input power
ON
OFF
Control circuit
External accessory wiring diagram is shown in
dashed frame
CD2 Motor Operator
Dimension
Mounting Diagram of MS2 Handle Padlocking Device
Type
MS2 Handle Padlocking Device
Handle of DC MCCB
Mounting the lock here
MS1 device, which incorporated
the circuit breaker with mounting
screws, is integrated handle
padlocking device preventing
mis-operation. It is currently for
frame size of 125 and 250 only.
Please refer to left diagram and
below table for installation
dimension. (DC MCCB is shown in
dashed frame)
Code illustration:SB1, SB2: Operation button (prepared by user)X: Wiring teriminalP1, P2: Input power
Voltage:
MS2 device, which mounting on the side of DC MCCB, is split type handle padlocking device preventing
mis-operation. Please refer to below diagram for installation dimension. (DC MCCB is shown in dashed
frame)
4039
Handle Operating Mechanism
Cutouts Sketch Map for Installation of CS1-A Handle Operating Mechanism
Cutouts Sketch Map for Installation of CS1-F Handle Operating Mechanism
Cutouts Sketch Map for Installation of CS2-F Handle Operating Mechanism
Installation Methord and Dimensions
External Accessories
HandleOperating
Mechanism
Matching MCCB
Metal Plastic
InstallationMethod
Vertical
Vertical
Vertical
Horizontal
Horizontal
Vertical
Manual Installation Dimensions ( mm )Model of External
Accessories
Cutouts Sketch Map for Installation of CS2-A Handle Operating Mechanism
Note: A is for round handle F is for quadrate handle
DC MCCB
or
or
or
Hinge
DC MCCB
or
Hinge
axis
4241
Interlock
Application
Dimension
Left rail
Handle of MCCB
Dimension Note
For
For
250 Type
630 Type
Supporting bracket Locating element 1 Right rail Slide block Fastening screw
Padlock position
Locating element 2
Operation Instruction
This interlock, which can be applied on the front of every two DC MCCBs, can
prevent simultaneous closing of every two DC MCCBs. It is simply in
construction and easily for operating. It can also be equipped with padlock.
Adjust the location of the rail to make sure one DC MCCB is OFF, and then
fasten the screw avoiding the other DC MCCB's operating way.
The rail can be adjusted and fasten by a padlock with locating element 1 and
2. (Padlock should be prepared by user. Locating element can be ordered as
accessory with DC MCCB.)
Interlock should be fasten on the mounting plate and the supporting bracket.
4443
2- A×B
H1
H2
H1
47
75
H2
25
33
A
6.5
9
B
10
12.5