Manual de Usuario MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP CON GAS REFRIGERANTE RESPETUOSO CON EL MEDIO AMBIENTE

Upload: others

Post on 27-Oct-2019

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

Manual de Usuario

MUND CLIMA®

SÓLO FRÍO:

BOMBA DE CALOR:

MUP-07 CNMUP-09 CNMUP-12 CNMUP-16 CN

MUP-07 HNMUP-09 HNMUP-12 HNMUP-16 HN

SPLIT DE PAREDSerie MUP

CON GASREFRIGERANTE

RESPETUOSO CON ELMEDIO AMBIENTE

Page 2: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

INDICE

Funciones y mantenimiento Pag.Instrucciones antes del uso 1Nombres y funciones de las piezas 3Mando a distancia

Teclas de función 4Funciones principales 5

Refrigeración 6Calefacción 7Deshumidificación 8Modo automático 9Programación 10Sleep 11

Utilización y mantenimiento 13Consejos para el usuario 14Mantenimiento y precauciones 15Resolución de problemas 17Especificaciones técnicas 18

InstalaciónAccesorios y diagrama de instalación 20Dimensiones de la instalación 21Ubicación de la instalación 22Instalación de la unidad interior 23Instalación de la unidad exterior 25Instalación de la unidad Fresh Air 27Revisiones previas a la puesta en marcha 28

Gracias por haber elegido MUNDOCLIMA, conserve este manualpara posteriores consultas.

MUND CLIMA®

Page 3: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

Instrucciones antes del uso

1

Advertencias básicas

Conecte el enchufe demanera correcta utilizan-do el voltaje y frecuenciaespecificados.Podría ocurrir una descargaeléctrica o incendio debido ala generación de calor.

Utilice el interruptor paraencender y apagar la uni-dad.Nunca tire el cordón eléctricopara desenchufar.

No dañe los cables niutilice ninguno que no sehaya suministrado defábrica.Pod r ía ocas iona r unadescarga eléctrica o incendio.

Evite manejar el equipocon las manos húmedas.Podría ocurrir una descargaeléctrica.

No introduzca ningún ob-jeto dentro de las unida-des.Podría resultar peligroso paraobjetos o personas.

No modifique el cableeléctrico ni comparta latoma de corriente conotros aparatos.Podría ocurrir una descargaeléctrica.

Desconecte el equipo encaso de situaciones anor-males (olor a quemado,humos, etc.).

No intente reparar elequipo sin asistencia.Contacte con su Centro deAsistencia.

No dirija la corriente deaire directamente haciapersonas.Podría ser causa de deterioropara la salud.

Peligro

MUND CLIMA®

Apag

ue e

l

inte

rrup

tor

Page 4: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

Advertencias básicas

Utilice fusibles con la ca-pacidad prevista. No uti-lice trozos de cables comofusible.Podría ocurrir una descargaeléctrica o incendio debido ala generación de calor.

Desconecte la corriente siel equipo no se utiliza du-rante un largo periodo.

Cuando limpie el equipoapague el interruptorprincipal.Podría ocurrir una descargaeléctrica.

No ponga fuentes de ca-lor cerca del equipo.Podría generar combustiónincompleta.

Mantenga aerosolescombustibles lejos delequipo.Podrían incendiarse o explo-tar.

No desconecte el enchufetirando del cable.Podría ocurrir una descargaeléctrica o incendio.

No ponga nada encimade la unidad exterior.

No cuelgue o ponga nadacerca de la salida delaire.Podría causar una disminu-ción del rendimiento.

Asegúrese periódica-mente de que el equipoestá bien instalado.La unidad podría caerse yprovocar lesiones.

2

MUND CLIMA®

Page 5: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

3

Nombres y funciones de las piezas

Unidad interior

Unidad exterior

Entrada de aire

Salida de aire

Salida de aire

Entrada de aire

Panel frontalPurificador de aireFiltrosInterruptor de modoTapa de conexionadoDeflectoresCable de alimentaciónManguera de desagüeCarcasaRejilla frontalMando a distancia

MUND CLIMA®

MUND CLIMA®

67

11

9

10

8

Page 6: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

“ ”

“ ”

“ ”

“ ”

4

Mando a distancia

Funciones principales del mando a distancia:

AT E N C I Ó N- Asegúrese de que no hay obstáculos entre el mando y el receptor.- La señal puede ser recibida desde una distancia de hasta 10 metros.- Utilice el mando a distancia con cuidado. No lo lance ni lo deje caer.- No deje el mando expuesto directamente al sol o cerca de una fuente de calor.

FUNCIÓN ALETASBotón para activar odesactivar las aletas.

FUNCIÓNTEMPERATURABotón para variar latemperatura deseada.La temperatura en elmando puedeaumentar hasta 30ºCy bajar hasta 16º C.

MODO DE FUN-CIONAMIENTOBotón para seleccionarel modo en secuenciaentre:

VENTILADORBotón para seleccionarla velocidad.

ENCENDIDO -APAGADO

Refrigeración

Calefacción

Deshumidificación

Ventilación

MUND CLIMA®

MODE ON/OFF

Page 7: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

5

Funciones del mando a distancia.

ATENCIÓNEste mando a distancia contiene algunos botones que no tienen aplicación en losmodelos que trata este Manual (botones LIGHT, AIR, HUMID, ANION y SAVE) ya quese utilizan en modelos de gamas distintas. Los botones que no sirven no afectan elfuncionamiento normal del aparato de aire acondicionado.

Display de cristallíquido

FUNCIÓNAMIENTONOCTURNOBotón para ajustar latemperatura de noche.

PROGRAMADORDE APAGADOBotón para programar elapagado a la horadeseada.

Cancelación delprogramador

PROGRAMADOR DEENCENDIDOBotón para programar elencendido a la horadeseada.

Cancelación delprogramador

Mando a distancia

RENOVACIÓN DEAIREAir 1 : ContinuoAir 2 : 1 Hora

Solo para modelos conFresh Air

MUND CLIMA®

MODE ON/OFF0 24h

0 24h

Page 8: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

6

REFRIGERACIÓN:

- De acuerdo con la diferencia de temperatura entre el ambiente y lo programado, elmicroprocesador pone en marcha el aparato en frío.

- Si la temperatura del ambiente es superior a la indicada, el aparato funciona enfrío.

- Si la temperatura del ambiente es inferior a la indicada, el compresor se para y solofunciona el ventilador de la unidad interior.

- El intervalo de temperatura es de 16º C a 30º C.

4. Presione el botónpara seleccionar la veloci-dad del ventilador.

FAN

MODE

1. Presione el botón y elaparato se pondrá en marcha.

ON/OFF

2. Presione el botónhasta la función Refrigera-ción.

MODE

5. Presione el botónpara ajustar el aparato ala temperatura deseada.

TEMP.

3. Presione el botónpara ajustar la dirección delaire. Al pulsar una vez losdeflectores se mueven, a lasegunda se paran.

SWING

Modos de funcionamientoMUND CLIMA®

MODE ON/OFF

Page 9: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

7

CALEFACCIÓN:

- Si la temperatura del ambiente es inferior a la indicada, el aparato funciona encalefacción.

- Si la temperatura del ambiente es superior a la indicada, el compresor y el ventila-dor de la unidad exterior se paran y solo funciona el ventilador de la unidad interior.

- El intervalo de temperatura es de 16º C a 30º C.

4. Presione el botón paraseleccionar la velocidad delventilador.

FAN

3. Presione el botónpara ajustar la dirección delaire. Al pulsar una vez losdeflectores se mueven, a lasegunda se paran.

SWING

5. Presione el botónpara ajustar el aparato a latemperatura deseada.

TEMP.

2. Presione el botónhasta la función calefacción.

MODE

1. Presione el botóny el aparato se pondrá enmarcha.

ON/OFF

Modos de funcionamientoMUND CLIMA®

MODE ON/OFF

Page 10: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

8

1. Presione el botón y elaparato se pondrá en marcha.

ON/OFF

DESHUMIDIFICACIÓN:

- Si la temperatura del ambiente es inferior a la indicada, el compresor y los ventila-dores de la unidad interior y exterior se paran.

- Si la temperatura del ambiente es 2º C de diferencia a la indicada, el aparatofunciona en modo deshumidificación.

- Si la temperatura del ambiente es superior a la indicada, el aparato funciona enmodo refrigeración.

- El intervalo de temperatura es de 16º C a 30º C.

4. Presione el botónpara ajustar el aparato ala temperatura deseada.

TEMP.

3. Presione el botónpara ajustar la

dirección del aire. Al pulsaruna vez los deflectores semueven, a la segunda separan.

SWING

Modos de funcionamiento

2. Presione el botónhasta encontrar la funcióndeshumidificación. Apartir de este momento lavelocidad del ventilador semantiene fija.

MODE

MUND CLIMA®

MODE ON/OFF

Page 11: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

9

AUTO: Modo automático

El microprocesador selecciona automáticamente el modo de funcionamiento desea-do, según la temperatura de la habitación.- Si la temperatura del ambiente está por debajo de los 20º C, el aparato funciona enmodo calefacción hasta que no alcance los 22.

- Si la temperatura del ambiente está por encima de los 25º C, el aparato funcionaen modo refrigeración hasta que no alcance los 23.

- Con este margen de temperaturas se consigue que la habitación se mantenga auna temperatura de 22-23ºC.

1. Presione el botón y elaparato se pondrá en marcha.

ON/OFF

2. Presione el botón hasta lafunción Auto. Desde este momentoel aparato seleccionará la funciónmás adecuada de acuerdo con latemperatura de la habitación

MODE

Modos de funcionamientoMUND CLIMA®

Page 12: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

10

MODE

PROGRAMADOR:

Con este modo de funcionamiento podemos programar tanto la conexióncomo la desconexión del equipo. El programador consta de una memoria de24 horas.

ON/OFF

PROGRAMADORDE ENCENDIDOBotón para programar elencendido a la horadeseada.

PROGRAMADORDE APAGADOBotón para programar elapagado a la horadeseada.

Modos de funcionamientoMUND CLIMA®

Cancelación delprogramador

0 24h

Cancelación delprogramador

0 24h

Page 13: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

11

MODE

SLEEP:

Al seleccionar esta función el microprocesador controla automáticamente la tempe-ratura de la habitación.- Si el aparato está funcionando en modo Refrigeración o Deshumidificación, la

temperatura fijada aumentará en 1º C la primera hora y en 2º C la segunda hora.- Si el aparato está funcionando en modo Calefacción, la temperatura fijada dismi-

nuirá en 1º C la primera hora y en 2º C la segunda hora.

ON/OFF

4. Presione el botónpara seleccionar lavelocidad del ventilador.

FAN

3. Presione el botónpara ajustar la dirección delaire. Al pulsar una vez losdeflectores se mueven, a lasegunda se paran.

SWING

5. Presione el botónpara ajustar el aparato ala temperatura deseada.

TEMP.

1. Presione el botón y elaparato se pone en marcha.

ON/OFF

2. Presione el botónpara seleccionar la funcióndeseada.

MODE

6. Presione el botónpara el FuncionamientoNocturno.

SLEEP

Modos de funcionamiento

MUND CLIMA®

Page 14: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

12

1. Quite la tapa de la partetrasera del mando.

3. Coloque la tapa.

2. Ponga las pilas.

Mando a distancia. Colocación de las pilas.

Utilización y mantenimiento

1. Quite la tapa de la partetrasera del mando.

2. Ponga dos pilas (tipo AAAsecas) y pulse el botón ACL.

3. Coloque la tapa en la partetrasera del mando.

MUY IMPORTANTE

-No utilice pilas recarga-bles. Estas son diferentespor rendimiento, forma ytamaños.

-Quite las pilas si el equipono va a ser puesto enmarcha durante un largotiempo.

-La señal del mando puedeser recibida a una distan-cia hasta de 10 metros.

-En condiciones normalesde funcionamiento laspilas suelen durar aproxi-madamente un año.

-No deje el mando cerca deaparatos eléctricos ofuentes de calor.

-Asegurese de remplazarlas pilas con dos pilasnuevas del mismo tipo.

MUND CLIMA®

Page 15: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

13

Condiciones óptimas para el funcionamiento correctodel equipo de aire acondicionado.

Ajuste la temperatura dela habitación

correctamente.Demasiado frío podría

dañar la salud.Desconecte el

aparato si no va aser utilizado

durante un largotiempo.

Limpie periódicamente elaparato con un trapo suave yseco. Limpie los filtros con una

aspiradora o con agua yséquelos a la sombra.

Quite las pilas del mando adistancia si no va a ser

utilizado durante un largotiempo.

Mantenga ventanas,cortinas y puertas biencerradas para evitarintercambio de aire.

Utilización y mantenimientoMUND CLIMA®

Page 16: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

14

Ajuste la correcta temperatura de la habitación.Puede ahorrar energía.

Mantenga 5º C dediferencia entre

ambiente interiory exterior.

Posicione los deflectores oportunamente parapermitir al aire frío salir hacia arriba y al calientehacia abajo.

No deje ventanas y puertas abiertas mientras elaparato funciona. Podría disminuir notablementela potencia de acondicionamiento.

No dirija el caudal de aire hacia animales oplantas. Podría causar mal estado para ellos.

Rociar agua en el aparato podría causar malfuncionamiento.

El aparato ha de funcionar con un voltaje correctoy estable. Cualquier otra tensión de alimentaciónpodría dañar el equipo

Conecte el aparato con la toma de tierra. La tomade tierra ha de ser la correcta, no la conecte aningún tipo de tubería, ni ningún otro tipo decable.

No utilice el aparato para otros propósitos comosecar la ropa, conservar alimentos, etc.

Consejos para el usuarioMUND CLIMA®

FRÍO

CA

LO

R

Page 17: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

15

Cuidado

+

+

+

Asegúrese de que el interruptor está apagado antes de cualquier mantenimiento delequipo.

Para la limpieza del aparato nunca utilice directamente agua o líquidos volátiles.

Limpie el aparato con un trapo seco o ligeramente húmedo.

Limpieza del panel frontal

1. Panel frontalAbra el panel frontal tirando hacia arribasuavemente.

2. LimpiezaLimpie el panel frontal con un trapo seco oligeramente húmedo. Para limpiar nuncautilice agua que exceda los 45º C, podríacausar deformación.

3. Panel frontalCierre el panel frontal tirando haciaabajo suavemente.

1. Panel frontalAbra el panel frontal y retírelo. Quite losfiltros con cuidado.

2. LimpiezaLimpie los filtros con una aspiradora o conagua y déjelos secar a la sombra.

Limpieza de los filtros (recomendado una vez al mes)

NOTA IMPORTANTEPara limpiar los filtros nunca utiliceagua que exceda los 45º C, podríacausar deformación.

Filtros de aire

Ranura

Mantenimiento y precaucionesMUND CLIMA®

Page 18: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

16

3. FiltrosColoque los filtros con cuidado y cierre elpanel frontal tirando hacia abajo suave-mente.

Reemplazo de los filtros purificadores de aire (recomendado una vez cada tres años)

Preparación antes del uso

Mantenimiento después del uso

1. Filtros purificadores de aire

2. LimpiezaReemplace los filtros purificadores de airepor unos nuevos.

3. Panel frontal

(Véase el paso nº 1 en “Limpieza de los filtros”)

(Véase el paso nº 3 en “Limpieza de los filtros”)

1. Asegúrese de que no hay objetos queobstruyan las salidas de aire de launidad interior y exterior.

2. Controle la buena conexión con la tomade tierra.

3. Reemplace los filtros si es necesario.4. Reemplace las pilas del mando si es

necesario.

1. Limpie los filtros y la parte frontal delaparato.

2. Deje el aparato funcionando en modoVentilación durante unas horas paraque se sequen las piezas interiores.

3. Controle la buena conexión con la tomade tierra.

4. Reemplace los filtros si es necesario.5. Reemplace las pilas del mando si es

necesario.6. Desenchufe el aparato.

Filtros purificadoresde aire.

Mantenimiento y precaucionesMUND CLIMA®

Page 19: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

17

Antes de acudir a un Servicio de Asistencia Técnica, consulte estos puntos. De este modo podráahorrar tiempo y dinero.

Situación Posible causa

Cuando se vuelve aponer en marcha, elaparato no funcionade inmediato.

En la habitaciónhay un olor a hú-medo no común.

Se oye un sonidode agua corrien-te o gotas quecaen.

El aire que sale dela unidad interiorparece neblina.

Al poner en marchao apagar el aparatose escucha un cru-jido.

El aparato nose pone enmarcha

La eficiencia en re-frigeración o cale-facción es muybaja.

El mando a distan-cia no funciona.

Cuando se apaga el aparato, el micropro-cesador espera tres minutos antes de unnuevo arranque para proteger el compre-sor.

Puede ser la humedad que desprenden lasparedes, alfombras, mobiliario o ropa.

Es el gas refrigerante que se desplaza enlas tuberías del aparato.

El aire de la habitación parece neblinacuando un caudal de aire frío la refrescarápidamente.

El cambio de temperatura deforma laspiezas de plástico del aparato.

¿ El enchufe está bien puesto?¿ Se ha puesto la función TIMER ON?¿ Se ha abierto un interruptor de circuito?¿ El interruptor principal está en “OFF”?

¿ Las puertas y ventanas están cerradas?¿ La entrada o salida de aire estáobstruida?¿ Los filtros están sucios?

¿ Se utiliza el mando a la distanciacorrecto?¿ Las pilas están descargadas?¿ Hay objetos entre el mando y elequipo?

Resolución de problemasMUND CLIMA®

Espere!

Page 20: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

Especificaciones técnicasES

PEC

IFIC

AC

ION

ES T

ÉCN

ICA

S

18

Gas

W2000

2500

3500

4500

2000

2500

3500

4500

BT

U/h

7000

9000

12000

15500

7000

9000

1200

16000

Kcal/h

1750

2150

3000

3900

1750

2150

3000

3900

W-

--

-2300

3000

3800

4900

BT

U/h

--

--

8000

9600

13200

16800

Kcal/h

--

--

2000

2400

3300

4200

Pote

ncia

absorb

ida

Refr

igera

ció

nW

940

1200

1620

2000

940

1200

1620

2000

Pote

ncia

absorb

ida

Cale

facció

nW

--

--

1050

1080

1820

2000

Capacid

ad

Deshum

idific

ació

nL/h

0,8

1,2

1,6

20,8

1,2

1,6

2

Circula

ció

ndelaire

m3/h

420

420

520

580

420

420

520

580

Volt-F

ases-F

recuencia

V-H

z-P

h

Niv

elsonoro

unid

ad

inte

rior

(*)

dB

(A)

34

34

38

43

34

34

38

43

Niv

elsonoro

unid

ad

exte

rior

(**)

dB

(A)

43

(52)

43

(54)

45

(57)

46

(57)

43

(52)

43

(54)

45

(57)

46

(57)

Ancho

unid

ad

inte

rior

mm

Alto

unid

ad

inte

rior

mm

Pro

fundid

ad

unid

ad

inte

rior

mm

Ancho

unid

ad

exte

rior

mm

Alto

unid

ad

exte

rior

mm

Pro

fundid

ad

unid

ad

exte

rior

mm

Peso

unid

ades

int./e

xt

Kg

11/3

511/3

5

Diá

metr

otu

bo

Gas

Pulg

.

Diá

metr

otu

bo

Líq

uid

oP

ulg

.

Máxim

alo

ngitud

linea

frig

orí

fica

m

Máxim

odesniv

el

m

R407C

230-5

0-1

830

285

1/2

"

189

848

(888

para

KF

-nnG

W/H

)

540

320

5

Capacid

ad

Cale

facció

n

Capacid

ad

Refr

igera

ció

n

1/4

"

10

11/3

211/3

2

3/8

"1/2

"3/8

"

MUND CLIMA®

Modelo

MUP

-07

CNM

UP-0

9 CN

MUP

-12

CNM

UP-1

6 CN

MUP

-07

HNM

UP-0

9 HN

MUP

-12

HNM

UP-1

6 HN

* N

ivel

son

oro

a m

áxim

a ve

loci

dad

(1 m

etro

de

dist

anci

a)**

Niv

el s

onor

o a

dist

anci

a 3

met

ros

(dis

tanc

ia 1

met

ro s

egún

CE)

Page 21: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

Manual de Instalación

MUND CLIMA®

SÓLO FRÍO:

BOMBA DE CALOR:

MUP-07 CNMUP-09 CNMUP-12 CNMUP-16 CN

MUP-07 HNMUP-09 HNMUP-12 HNMUP-16 HN

SPLIT DE PAREDSerie MUP

19

CON GASREFRIGERANTE

RESPETUOSO CON ELMEDIO AMBIENTE

Page 22: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

Accesorios y diagrama de instalación

MUY IMPORTANTEAsegúrese de tener todos los accesorios antes de proceder a la instalación del equipo.

Utilice única y exclusivamente los accesorios suministrados por el fabricante, enprevención de fugas de gas, escapes de agua o posibles cortocircuitos.

20

Num Nombre Dibujo Uds Especificaciones Observaciones

1 Panel trasero 1

2 Control remoto 1

3 Pilas 2 1,5 V

4 Cable de alimentación 1

5 Cable de control 1 5 x 1,0 Solo parabomba de calor

6 Cable de control 1 3 x 0,75 Solo parabomba de calor

7 Tornillos de fijación 10 ST4.2 x 25 Fijación delpanel trasero

8 Tubería de desagüe 1 L=2m Incluido en kit deconexión

9 Masilla selladora 1 120x65x25

10 Protector salida de tubo 1 Incluido en kitde conexión

11 Cinta aislante 2 30 x 10 Incluido en kitde conexión

12 Tuberías de conexión,líquido y gas

1NO INCLUIDO

13 Coquilla aislante líneafrigorífica

1

14 Filtros de aire 2 Incorporado enla unidad interior

15 Tubo ventilación Fresh Air 1 Solo paramodelos Fres Air

16 UnidadFresh Air

1 Solo paramodelos Fres Air

17 Abrazadera tubo FreshAir

2 Solo paramodelos Fres Air

18 Codo de desgüe 1 Solo paramodelos Fres Air

MUND CLIMA®

Page 23: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

Dimensiones de instalación

15 cm o máshasta el techo

15 cm o máshasta la pared

15 cm o máshasta la pared

30 cm comomínimo para lasalida de aire

30 cm o máshasta la pared

200 cm comomínimo para lasalida de aire

15 cm o máshasta la pared

AVISO IMPORTANTE- La instalación ha de ser realizada por un profesional cualificado- El desmontaje o cambio de sitio de un equipo ha de ser supervi-

sado por un profesional- El equipo de aire acondicionado ha de tener una conexión correc-

ta a tierra, de no ser así, contacte con el servicio técnico.

Protector salida de tubo

Cinta aislante

Dimensiones de instalación

21

MUND CLIMA®

MUND CLIMA®

Page 24: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

Ubicación de la instalación

Unidad interior

1. La entrada y salida de aire no puede estar cubierta a efectos de repartir el aire por toda lahabitación.

2. Instalar en algún sitio donde sea fácil la conexión con la unidad exterior.3. En un lugar donde el agua de condensación pueda ser evacuada convenientemente.4. Evitar lugares próximos a fuentes de calor, alta humedad o gases inflamables.5. Instalar en un lugar lo suficientemente fuerte para aguantar el peso y las vibraciones de la

unidad.6. Asegúrese que la instalación cumple las distancias mínimas de instalación..7. Asegúrese de dejar el suficiente espacio para facilitar el mantenimiento rutinario. La altura de

instalación debe de ser de unos 2,3 metros desde el suelo.8. Instalar a más de un metro de altura desde otros componentes eléctricos como pueden ser

televisión, dispositivos de audio, etc.9. Seleccione un lugar desde donde sea fácil el cambio de filtros.10. No use la unidad en alrededores inmediatos de lavanderías, baños, duchas o piscinas.

Unidad exterior

1. Seleccione un lugar donde el aire y el ruido emitidos por la unidad no moleste a los vecinos.2. Seleccione una lugar de elevada ventilación.3. La entrada y salida de aire no pueden estar obstruidas.4. Instalar en un lugar lo suficientemente fuerte para aguantar el peso y las vibraciones de la uni-

dad.5. No puede haber peligro de gases inflamables o corrosivos.6. Asegúrese que la instalación sigue las distancias recomendadas en el diagrama de dimensiones

de instalación

ATENCIÓNLa instalación en los siguientes sitios puede causar mal funcionamiento.Si es irremediable contacte con el servicio técnico- Lugares donde se usan aceites.- Lugares con alto nivel de salinidad en el ambiente.- Sitios expuestos a gases sulfúricos.- Lugares donde se generen ondas de alta frecuencia, producidas por

equipos de radio, equipamientos médicos, etc.- Cualquier otro sitio bajo circunstancias especiales.

22

MUND CLIMA®

Page 25: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

23

Instalación de la unidad interior

CurvadoInclinado

Instalación del panel trasero

1. Para un buen drenaje, coloque el paneltrasero de forma horizontal y en cual-quier caso un poco hacia la izquierdapuesto que es el lado donde se encuen-tra el agujero de drenaje.

2. Fije el panel trasero con los tornillossuministrados con la unidad.

3. Asegúrese de que el panel está sujetocon la fuerza suficiente para aguantarun peso de unos 60 Kg.

Instalación del tubo de desagüe

1. Realice un agujero de desagüe en la paredcon una ligera inclinación hacia el exterior.Tome como referencia del centro la indicadaen la figura 1.

2. Inserte el manguito protector en el agujero, enprevención de posibles daños.

3. Coloque la manguera con una ligera inclina-ción hacia abajo.

4.No incline hacia arriba, ni curve la maguera,podría derramarse agua.

MUY IMPORTANTE- Conecte las tuberías de gas y líquido, primero la unidad interior y luego la uni-

dad exterior.- Tenga cuidado al curvar las tuberías, podría dañarlas- Apriete las tuercas de forma correcta para evitar posibles escapes

Instalación eléctrica1. Abra el panel frontal2. Extraiga la cubierta del cableado3. Ubique el cable de conexión desde la unidad interior pasando por el agujero de conexión4. Conecte el cable azul de tensión de alimentación al terminal “N(1)”, el marrón al “2” y el

amarillo-verde a la conexión de tierra como marca la figura 4. El los modelos de potencia máselevada (MUP-16 CN y MUP-16 HN) de toda la gama, sera necesaria la conexión del cable decolor rojo al terminal “3”.

5. Para los modelos con bomba de calor conecte los cables de control como indica la figura 4, ysujete el cable al chasis.

6. Colocar el protector de conexiones eléctricas7. Montar el panel frontal

Instalación del tubo Fresh AirPara la instalación del tubo Fresh Air consulte lapágina 27

(Fig. 1)

MUND CLIMA®

Page 26: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

24

Instalación de la unidad interior

ATENCIÓN- Todo el conexionado eléctrico ha de ser realizado por personal cualificado acorde con la

normativa local vigente.- La conexión a la red ha de realizarse como indica este manual.- Es necesario instalar un circuito de desagüe.- Utilice el fusible indicado- Si el cable de alimentación esta dañado, ha de ser reemplazado por el fabricante o su

servicio técnico a efectos de evitar posibles peligros.- El diámetro del cable de alimentación es el correcto, utilice exclusivamente este cable para su

substitución en caso avería.-El cableado ha de cumplir la normativa vigente.

Recorte 1Recorte 2Agujero

Fig. 5

Fig. 6

Cable decontrol (solobomba de

calor)

Cable dealimentación

Tubo dedesagüeTubos de

gas y líquido

Cintaaislante

Instalando la unidad interior1. Cuando se hayan ubicado las tuberías de gas y líquido,

desde la derecha o izquierda de la unidad interior, cortelos pestañas laterales como se muestra en la figura 5.

- Recorte el circular cuando solo pase cable.- Recorte el número 1 o 2 para tubos y cables.

2. Encinte los cables y tuberías desde el recorte, como semuestra en la figura 6.

3. Compruebe que la sujeción al panel trasero es lo suficien-temente fuerte.

4. La altura desde el suelo hasta la unidad interior ha de serde unos 2,3 metros.

Cable de control5 x 1,0

Conector deconexion

Abrazadera

Cable de control3 x 0,75

Protector deconexión eléctrica

Cable deconexión

Fig. 4

MUND CLIMA®

Page 27: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

25

Cubiertalateral

Instalación de la unidad exterior

Instalación de las tuberías de conexiónLlave inglesao fija

Llave inglesao fija

JuntaTuerca

Cable decontrol

AzulMarrón Amarillo

Verde

RedAbrazaderas

Solo bombade calor

Quite los tornillos parasacar la cubierta superior

Tornillos deabrazadera

Fig. 8

1. Centre las tuercas de conexión con su tubería correspondiente2. Apriete las tuercas tal y como indica la figura de la derecha (Fig. 7).

Fig. 7

ATENCIÓNAplicar una fuerza excesiva a la hora deunir las tuercas puede dañar la conexión

Cableado de conexión eléctrica

1. Extraiga la cubierta lateral2. Extraiga los tornillos de la abra-

zadera y conecte el final delcable de conexión a los termina-les correspondientes. Asegúreseque la conexión está acorde conla unidad interior.

3. Coloque de nuevo la abrazaderay una los cables usando losconectores.

4. Asegúrese que la conexión seafirme.

5. Vuelva a montar la cubiertalateral.

MUY IMPORTANTE- Una mala conexión ocasionará mal funcionamiento.- Tenga cuidado a la hora de poner la abrazadera.- No deje el cable exterior demasiado largo.

Diámetro Par (N.m)

1/4 15 a 20

3/8 30 a 35

1/2 50 a 55

MUND CLIMA®

Page 28: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

26

Instalación de la unidad exterior

Válvulade gas

Válvulade líquido

Válvula deservicio

Tuerca

Bombade vacío

Tubo delíquido

Tubode gas

Soportemetálico

Salida dedesagüe

Fig. 9

Fig. 10

Fig. 11

Rosca depresión

Vacío del circuito

1. Con las válvulas totalmente cerradas (tal y comovienen de origen) conectar la manguera de bajapresión (Azul) del analizador al obús de carga dela válvula de 3 vías (válvula de gas)

2. Conectar la manguera central del analizador(Amarilla) a la bomba de vacío

3. Poner en marcha la bomba de vacío y abrir lallave de baja (Lo) del analizador. La aguja delmanómetro de baja se moverá por debajo de 0.Mantener el funcionamiento de la bomba duranteal menos 20 minutos. (Si el manómetro no cambiade 0 a -0,76 Kpa o -30 lbs el circuito frigoríficoestá abierto, revisar dado que podría ser unafuga).

4. Cerrar la llave de baja (Lo) del analizador y apa-gar la bomba. Atención siempre en este ordenCERRAR y PARAR. Mantener durante aproximada-mente 10 minutos controlando que la aguja no semueve. Esto se hace para comprobar que no hayfugas. En caso contrario, será necesario detectar elpunto de fuga y repararlo

5. Abrir totalmente las válvulas de servicio con unallave hexagonal

6. Poner la máquina en marcha el sistema y compro-bar que la presión de trabajo es la correcta

7. Desconectar las mangueras de carga de la bombade vacío y del obús de carga

8. Montar los tapones de las válvulas

Drenaje del agua de condensación(Solo para modelos conbomba de calor)

Cuando la unidad esta dando calor, el agua generada enla unidad exterior es evacuada utilizando un sistema dedrenaje como el que se muestra en la figura 11.La instalación de este sistema consiste en la ubicación deldispositivo de desagüe en el lugar apropiado.

MUND CLIMA®

Puente de manómetros

Page 29: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

27

Instalación de la unidad Fresh Air

Codointerior

AbrazaderaInterior

FreshAir

La longitud del tubo para Fresh Air es de 5m,en el caso de que esta distancia no fuesesuficiente, cabe la posibilidad de interconectardos tubos Fresh Air como se muestra acontinuación:

Salida deaire

Abrazaderaexterior

Mangera

Abrazaderapequeña

Abrazaderagrande

InterconexiónTubooriginal Tubo

suplementario

MUND CLIMA®

MUND CLIMA®

Page 30: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

Comprobar después de instalar

COMPROBAR POSIBLE MAL FUNCIÓN ESTADO

¿ Está fijado firmemente? La unidad podría caerse, moverse o emitir ruido

¿Se ha hecho un chequeo de fugas? Podría generar una capacidad refrigerante insuficiente

¿Es suficiente el aislamiento decalor?

Podría generar condensación y vertido de agua

¿Es correcto el drenaje? Podría generar condensación y vertido de agua

¿La tensión de alimentación es laque marca la placa eléctrica?

Podría dañar el equipo

¿Es correcta y segura la instalaciónrealizada ?

Podría dañar el equipo

¿La conexión a tierra es correcta? Podrían generarse descargas eléctricas

¿Es el cable de alimentaciónespecificado?

Podría dañar el equipo

¿Están cubiertas las entradas ysalidas de aire?

Podría disminuir la capacidad de refrigeración

¿Es la carga de refrigerante acordecon la distancia de los tubos?

La capacidad del refrigerante no es la óptima

28

Operación de Test

1. Antes del test :- No conecte el equipo hasta que esté

completamente instalado- La conexión eléctrica ha de ser correcta y segura- Las válvulas han de estar abiertas- El equipo ha de estar libre de impurezas- Abra el panel frontal y coloque el interruptor en la

posición RUN

Interruptorde modo2. Método de la operación de test

- Conecte el equipo y pulse el botón ON/OFF del mando a distancia- Pulse el botón MODE para comprobar que funcionan los tres modos forzados:

FRIO, CALOR, DESHUMIDIFICACIÓN- Sin utilizar el mando compruebe que en la posición AUTO la temperatura depende del

ambiente, y en STOP el equipo se detiene por completo

NOTA: El modo TEST es solamente para realizar pruebas. No utilizar comomodo de funcionamiento normal

MUND CLIMA®

Revisiones previas a la puesta en marcha

Page 31: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

Casos en los que hay que desenchufarel aparato y contactar directamentecon su instalador.

- Se oyen ruidos raros durante el funciona-miento del aparato.

- Los fusibles se queman a menudo.- Por descuido se cae agua u otro objeto en elinterior del aparato.

- El cable de alimentación o el enchufe estánmuy calientes.

- El caudal de aire que sale del aparato hueleterriblemente.

¡ ATENCIÓN !

NOTA INFORMATIVASalvador Escoda S.A., en cumplimiento de la Ley de las Garantías, informa que todas lasmáquinas de aire acondicionado vendidas a partir del 11 de Septiembre de 2003, tienen unagarantía de de mano de obra, desplazamiento y material de repuesto en las siguientescondiciones:

El usuario final deberá tener cumplimentada una factura, un albarán con los siguientes datos:marca de la máquina, modelo, números de serie de las unidades interiores y unidades exterioresy el nombre del instalador/vendedor con su dirección.

En el tiempo que dure la garantía,

La garantía no incluye ni los defectos de instalación, ni la toma de corriente, ni el desagüe de lamáquina de aire acondicionado, ni las roturas de mandos debidas a caidas o mal uso, siendoestas atendidas por el instalador/vendedor.

Salvador Escoda S.A. sólo se responsabiliza de los defectos de la máquina de aireacondicionado cuando estos sean de fabricación, no de manipulación ni de montaje por elinstalador/vendedor.

Salvador Escoda S.A. no atenderá directamente al usuario final en circunstancias normales, sóloatenderá al usuario final cuando éste no tenga posibilidad de encontrar al instalador/vendedor ysiempre que la máquina de aire acondicionado esté en garantía.

Fuera de garantía pasará el aviso a sus Servicios Técnicos, que le facturarán directamente alusuario en las condiciones establecidas

2 AÑOS

será el instalador/vendedor quien requiera losservicios del S.A.T. indicando la posible avería del equipo de aire acondicionado yacompañando a el mismo.

S.A.T. Tel. 93 652 53 57 - Fax 93 635 45 08MUND CLIMA®

Page 32: MUND CLIMA - mundoclima.com · MUND CLIMA ® SÓLO FRÍO: BOMBA DE CALOR: MUP-07 CN MUP-09 CN MUP-12 CN MUP-16 CN MUP-07 HN MUP-09 HN MUP-12 HN MUP-16 HN SPLIT DE PARED Serie MUP

MUND CLIMA®

SALVADOR ESCODA S.A.®[email protected]

BADALONA - Delegación:

HOSPITALET - Tienda Llob.

BARBERÀ - Tienda Vallès:

ALBACETE - Delegación:

ALICANTE - Delegación:

CASTELLÓN - Delegación:

CÓRDOBA - Delegación:

GRANADA - Delegación:

JAÉN - Delegación:

LLEIDA - Delegación:

MADRID 1 - Delegación:

MADRID 2 - Delegación:

MÁLAGA - Delegación:

MURCIA 1 - Delegación:

MURCIA 2 - Delegación:

REUS - Delegación:

SEVILLA - Delegación:

VALENCIA 1 - Tienda:

VALENCIA 2 - Delegación:

ZARAGOZA - Delegación:

Industria 608-612Tel. 93 460 55 00Fax 93 460 55 4408918 Badalona

Mare de Déu Bellvitge, 246-252Tel. 93 377 16 75Fax 93 377 72 1208907 L'Hospitalet de Llobregat

Marconi, 23Tel. 93 718 68 26Fax 93 729 24 6608210 Barberà del Vallès

Pol. Campollano, D, p. 8-10Tel. 967 19 21 79Fax 967 19 22 4602006 Albacete

Artes Gráficas, 10-12Tel. 96 511 23 42Fax 96 511 57 3403008 Alicante

Av. Enrique Gimeno, 24Tel. 96 424 72 11Fax 96 424 72 0312006 Castellón de La Plana

Polígono Las Quemadasc/. Juan Bautista E., p. 219Tel. 957 32 27 3014014 Córdoba

P. Juncaril, c/. Lanjarón, 10Tel. 958 49 10 50Fax 958 49 10 5118220 Albolote (Granada)

P. Olivares, Cazalilla, p. 527Tel. 953 28 03 01Fax 953 28 03 4623009 Jaén

Polígono Industrial SegriàCtra. N-230, km 5,400Tel. 973 75 06 9025123 Torrefarrera (Lleida)

Avda. de Castilla, 26Tel. 91 675 12 29Fax 91 675 12 8228830 S. Fernando Henares

c/. Fragua, 8Polígono Ind. Cantueña28944 Fuenlabrada

Alcalde Garret y Souto, 42Polígono Industrial El VisoTel. 952 04 04 0829006 Málaga

c/. Cuatro Caminos, 56Tel. 968 23 65 28Fax 968 20 43 9130007 Murcia

Pol. Oeste, c/ Principal 21/10Tel. 968 88 90 02Fax 968 88 90 4130007 Murcia

c/. Víctor Català, 46Tel. 977 32 85 68Fax 977 32 85 6143206 Reus (Tarragona)

J. Sainz de la Maza, PICAp170, m6-7-8, 41007 SevillaTel. 95 499 97 49Fax 94 499 99 14

c/. Río Eresma, s/n.ºTel. 96 395 62 64Fax 96 395 62 7446026 Valencia

Pol. nº 7, Brosquil n. III y IVTel. 96 147 90 75Fax 96 147 90 5246540 El Puig (Valencia)

Polígono Argualas, nave 51Tel. 976 35 67 00Fax 976 35 88 1250012 Zaragoza

Inauguración 1a mitad 2004

Solicíte listado de Servicios Técnicos de su província: Tel. 93 652 53 57 (S.A.T. Mundoclima)

ES UNA MARCA DE:

¡Los Especialistas en Aire Acondicionado!

ALICANTE

BARCELONABadalonaL'HospitaletBarberà V.

VALENCIA

Palma deMallorca

R

CASTELLÓN

REUS

SEVILLA

MADRID

ZARAGOZA

Mérida

PontevedraR

R

JAÉN

AsturiasR

MURCIA

GRANADA

MÁLAGA

LLEIDA

ALBACETE

CÓRDOBA

BARCELONA - Central:c/. Rosselló, 430-432 - 08025 BarcelonaTel. 93 446 27 80 - Fax 93 456 90 32

Red comercial