methamphetamine &...

6
Rapid and Accurate Chiral Separation METHAMPHETAMINE & AMPHETAMINE Enantiomers from Urine New Lux 3 µm AMP Column • High Efficiency • LC/MS/MS Compatible • Quality Tested for METH/AMP Chiral Analysis Polysaccharide Chiral LC and SFC Chiral LC Columns Phenomenex l WEB: www.phenomenex.com

Upload: others

Post on 31-Jan-2021

172 views

Category:

Documents


6 download

TRANSCRIPT

  • Rapid and Accurate Chiral Separation

    METHAMPHETAMINE & AMPHETAMINE Enantiomers from Urine

    New Lux 3 µm AMP Column• High Efficiency

    • LC/MS/MS Compatible

    • Quality Tested for METH/AMP Chiral Analysis

    Polysaccharide Chiral LC and SFCDependable. Scalable. A�ordable.

    Chiral LC Columns

    Phenomenex l WEB: www.phenomenex.com

  • A Trusted and Experienced Solution Provider For over 30 years Phenomenex has developed separation solutions for the forensics and toxicology industries. This strong focus, combined with innovative manufacturing, packing and sorbent technologies has now lead to the development of a novel LC column specifically designed to help you overcome the challenging drug separation of amphetamine and methamphetamine enantiomers.

    D-Methamphetamine

    S(+)-Methamphetamine

    HN

    D-Amphetamine

    S(+)-Amphetamine

    L-Amphetamine

    R(-)-Amphetamine

    Designed and Tested for Chiral Separation of Amphetamine and Methamphetamine Enantiomers

    Lux 3 µm AMP is a unique LC media that was specifically developed for the chiral analysis of amphetamine and substituted amphetamines, including methamphetamine. This type of separation is invaluable for forensics, toxicology, and clinical research labs that need to analyze and confirm which enantiomers are found in samples to differentiate between therapeutic use and abuse.

    Lux 3 µm AMPL-Methamphetamine

    R(-)-Methamphetamine

    HN

    Polysaccharide Chiral LC and SFCDependable. Scalable. A�ordable.

    Chiral LC Columns

    Phenomenex l WEB: www.phenomenex.com

  • 0.00

    5.00e5

    1.00e6

    1.50e6

    2.00e6

    2.50e6

    3.00e6

    3.50e6

    4.00e6

    4.50e6

    5.00e6

    5.50e6

    6.00e6

    6.50e6

    7.00e6

    7.50e6

    8.00e6

    8.50e6

    9.00e6

    9.50e6

    1.00e71.03e7

    0.5 1.0 1.5 2.0 2.5 3.0 3.5 min

    0 2 4 6 8 10 12 min767

    1.0e6

    2.0e6

    3.0e6

    4.0e6

    5.0e6

    6.0e6

    1

    2

    3

    4

    Reversed Phase Screening and Presumptive TestingThe high performance and versatility of the Kinetex® 2.6 µm Biphenyl core-shell column makes it an excellent choice for a rapid reversed phase separation of multi-class screens like illicit and abused drugs from urine samples.

    Comparative separations may not be representative of all applications.

    Inte

    nsity

    , cps

    Inte

    nsity

    , cps

    Column: Kinetex 2.6 µm BiphenylDimension: 30 x 2.1 mm

    Part No.: 00A-4622-ANSecurityGuard™

    ULTRA Cartridge:

    AJ0-9209

    SecurityGuard™ Holder:

    AJ0-9000

    Mobile Phase: A: 10 mM Ammonium Formate in Water (pH unadjusted)

    B: 0.1 % Formic Acid in MethanolGradient: Time (min)

    0.00.22.52.93.03.5

    % B101090901010

    Flow Rate: 0.4 mL/minTemperature: 40 ˚C

    Injection Volume: 25 µLDetection: MS/MS (SCIEX 6500 QTRAP®)

    Column: Lux 3 µm AMPDimension: 150 x 3.0 mm

    Part No.: 00F-4751-Y0Mobile Phase: A: 5 mM Ammonium Bicarbon-

    ate, adjusted to pH 11 with Ammonium Hydroxide

    B: MethanolFlow Rate: 0.42 mL/min

    Gradient: Time (min)0101116

    16.3

    % B6060959560

    Temperature: AmbientDetection: MS/MS (SCIEX 4500 QTRAP®)

    Sample: 1. R(-)-Amphetamine2. R(-)-Methamphetamine3. S(+)-Amphetamine4. S(+)-Methamphetamine

    Sample:Positive Mode (ESI+) 1. 6-MAM 2. 7-Aminoclonazepam 3. 3 alpha- hydroxyalprazolam 4. Alprazolam 5. Amitriptyline 6. Amphetamine 7. Benzoylecgonine 8. Buprenorphine 9. Carisoprodol 10. Citalopram 11. Codeine 12. Cotinine 13. Diazepam 14. EDDP 15. Fentanyl 16. Fluoxetine 17. Gabapentin 18. Hydrocodone 19. Hydromorphone 20. Imipramine 21. Lorazepam 22. MDMA 23. Meperidine 24. Meprobamate

    25. Methadone 26. Methamphetamine 27. Methylphenidate 28. Morphine 29. Naloxone 30. Norbuprenorphine 31. Nordiazepam 32. Norfentanyl 33. Norhydrocodone 34. Noroxycodone 35. Normorphine 36. Nortriptyline 37. O-Desmethyltramadol 38. Oxycodone 39. Oxymorphone 40. Paroxetine 41. PCP 42. Pregabalin43. Sertraline44. Tapentadol45. Temazepam46. Tramadol47. Zolpidem48. Zolpidem-4- carboxylic Acid

    Negative Mode (ESI-) 1. Butalbital 2. Phenobarbital 3. Secobarbital 4. THC-COOH

    AP

    P ID

    23560A

    PP

    ID 23631

    Kinetex 2.6 µm BiphenylTIC of ESI+ Panel

    Methamphetamine

    Amphetamine

    Lux 3 µm AMP

    Inte

    nsity

    , cps

    Kinetex 2.6 µm Biphenyl

    0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 min0.0

    2000.04000.06000.08000.0

    1.0e41.2e41.4e41.6e41.8e42.0e42.2e42.4e42.6e42.8e43.0e4

    AP

    P ID

    23566

    Enantiomeric Definitive TestingOnce presence of amphetamine or methamphetamine has been determined, enantiomeric confirmation can then easily be achieved with a Lux® 3 µm AMP column.

    TIC of ESI- Panel

    Phenomenex l WEB: www.phenomenex.com

  • Not Affected by Common Interferences Another excellent benefit of the Lux® 3 µm AMP is that its separation of amphetamine and methamphetamine enantiomers isn’t affected by common therapeutics and ingredients such as those seen below. In addition, the separation power of the Lux AMP column can also help with resolution between enantiomers of substituted amphetamines.

    1-Minute β-Glucuronidase Removal To remove β-Glucuronidase before it can build up and foul your LC instrumentation, Mass Spectrometer, and column, we recommend the use of Beta-Gone. This novel sorbent offers a simple, fast, and highly targeted method to remove β-Glucuronidase from hydrolyzed urine samples prior to analysis. Within 1 minute, with no necessary method development, your samples will be ready for analysis.

    www.phenomenex.com/beta-gone

    Comparative separations may not be representative of all applications.

    Inte

    nsity

    , cps

    Column: Lux 3 μm AMPDimension: 150 x 3.0 mm

    Part No.: 00F-4751-Y0Mobile Phase: A: 5 mM Ammonium Bicarbon-

    ate, adjusted to pH 11 with Ammonium Hydroxide

    B: MethanolFlow Rate: 0.42 mL/min

    Gradient: Time (min)0101116

    16.3

    % B6060959560

    Temperature: AmbientDetection: MS/MS (SCIEX 4500 QTRAP®)

    1. 1S,2R(+)-Ephedrine2. R,R(-)-Pseudoephedrine3. S,S(+)-Pseudoephedrine4. 1R,2S(-)-Ephedrine5. R(-)-Amphetamine6. R(-)-Methamphetamine7. S(+)-Amphetamine8. S(+)-Methamphetamine9. Phentermine10. MDMA11. MDMA

    Compounds included in this interference study but not illustrated chromatographically: acetaminophenaspirin(±)-chlorpheniraminecaffeinediphenhydraminedextromethorphanibuprofen(±)-MDA(±)-MDEAphenylephrinenorephedrine

    Sample:Positive Mode (ESI+) 1. 6-MAM 2. 7-Aminoclonazepam 3. 3 alpha- hydroxyalprazolam 4. Alprazolam 5. Amitriptyline 6. Amphetamine 7. Benzoylecgonine 8. Buprenorphine 9. Carisoprodol 10. Citalopram 11. Codeine 12. Cotinine 13. Diazepam 14. EDDP 15. Fentanyl 16. Fluoxetine 17. Gabapentin 18. Hydrocodone 19. Hydromorphone 20. Imipramine 21. Lorazepam 22. MDMA 23. Meperidine 24. Meprobamate

    25. Methadone 26. Methamphetamine 27. Methylphenidate 28. Morphine 29. Naloxone 30. Norbuprenorphine 31. Nordiazepam 32. Norfentanyl 33. Norhydrocodone 34. Noroxycodone 35. Normorphine 36. Nortriptyline 37. O-Desmethyltramadol 38. Oxycodone 39. Oxymorphone 40. Paroxetine 41. PCP 42. Pregabalin43. Sertraline44. Tapentadol45. Temazepam46. Tramadol47. Zolpidem48. Zolpidem-4- carboxylic Acid

    Negative Mode (ESI-) 1. Butalbital 2. Phenobarbital 3. Secobarbital 4. THC-COOH

    0 2 4 6 8 10

    1 2 3-45

    6

    7

    89

    1011

    12 14 16 18 min0

    1.0e6

    2.0e6

    3.0e6

    4.0e6

    5.0e6

    6.0e6

    7.0e6

    7.8e6

    AP

    P ID

    23640

    β-Glucuronidase Removal Products

    Phenomenex l WEB: www.phenomenex.com

  • 0.0

    2.0e4

    4.0e4

    6.0e4

    8.0e4

    1.0e5

    1.2e5

    1.4e5

    1.6e5

    1.8e5

    2.0e5

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 min

    Comparative separations may not be representative of all applications.

    Exceptional ReliabilityLux® 3 μm AMP media and columns are designed to be consistent and incredibly accurate tools for your amphetamine and methamphetamine analysis. Each batch is specifically tested by LC/MS for the analysis of amphetamine and methamphetamine, and columns are quality tested to ensure dependability and reproducibility.

    Amphetamine Enantiomers Methamphetamine Enantiomers

    AP

    P ID

    23629

    Excellent Lifetime

    Column: Lux 3 µm AMPDimension: 150 x 3.0 mm

    Part No.: 00F-4751-Y0Mobile Phase: A: 5 mM Ammonium Bicarbonate, adjusted

    to pH 11 with Ammonium HydroxideB: Methanol

    Flow Rate: 0.42 mL/minGradient: Time (min)

    0101113

    13.1

    % B6060959560

    Temperature: 22 °CSample: 1. Ephedrine

    2. Pseudoephedrine3. R(-)-Amphetamine4. S(+)-Amphetamine5. R(-)-Methamphetamine6. S(+)-Methamphetamine

    % o

    f Ini

    tial R

    eten

    tion

    Tim

    e

    R(-)-Amphetamine R(-)-MethamphetamineS(+)-Amphetamine S(+)-Methamphetamine

    Injection Count 1 350 7000

    20

    40

    60

    80

    100

    0.01.0e42.0e43.0e44.0e45.0e46.0e47.0e48.0e49.0e41.0e51.1e51.2e51.3e51.4e51.4e5

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 min

    AP

    P ID

    23628

    Resolution

    Batch A: 3.38 Batch B: 3.04

    Resolution

    Batch A: 2.11 Batch B: 1.64

    Ephedrine and Pseudoephedrine

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 min0.0

    1.0e42.0e43.0e44.0e45.0e46.0e47.0e48.0e49.0e41.0e51.1e51.2e51.3e51.4e51.5e51.6e5

    AP

    P ID

    23630

    Resolution

    Batch A: 2.04 Batch B: 1.91

    R(-)-Amphetamine R(-)-Methamphetamine

    1S,2R(+)-Ephedrine

    S(+)-Amphetamine

    S(+)-Methamphetamine

    S,S(+)- Pseudoephedrine

    Phenomenex l WEB: www.phenomenex.com

    If Phenomenex products in this brochure do not provide at least an equivalent separation as compared to other products of the same phase and dimensions, return the product with comparative data within 45 days for a FULL REFUND.

  • Ordering Information

    Rapid and Accurate Chiral Separation

    METHAMPHETAMINE & AMPHETAMINE Enantiomers from Urine

    NEW

    BR

    4244

    0416

    _W

    Lux® 3 µm Analytical ColumnsSecurityGuard™

    ULTRA Cartridges‡

    Phase 150 x 3.0 150 x 4.6 3/pk 3/pk

    AMP 00F-4751-Y0 00F-4751-E0 AJ0-9510 AJ0-9509

    for 3.0 mm ID for 4.6 mm ID

    Kinetex® 2.6 µm Analytical ColumnsSecurityGuard™

    ULTRA Cartridges‡

    Phase 30 x 2.1 50 x 2.1 50 x 3.0 3/pk 3/pk

    Biphenyl 00A-4622-AN 00B-4622-AN 00B-4622-Y0 AJ0-9209 AJ0-9208

    for 2.1 mm ID for 3.0 mm ID

    ‡SecurityGuard ULTRA Cartridges require holder, Part No.: AJ0-9000

    β-Gone™ β-Glucuronidase Removal Products

    Part No. Description Unit Price

    8B-S139-TAK 1 mL Tubes, Recombinant Enzyme 100/Box

    8B-S322-DAK 1 mL Tubes, Non-Recombinant Enzyme 100/Box

    8E-S139-TGA 96-Well Plate, Recombinant Enzyme 1/Box

    8E-S322-DGA 96-Well Plate, Non-Recombinant Enzyme 1/Box

    Verex™ Certified Mass Spec Quality Vials

    Description 1000/pk Price

    Cert+ MSQ Vial Kit, 9 mm, 2 mL Clear w/ Patch + MSQ PTFE/Silicone

    AR0-992A-13-M

    Cert+ MSQ Vial Kit, 9 mm, 2 mL Amber w/ Patch + MSQ PTFE/Silicone

    AR0-992B-13-M

    Terms and Conditions Subject to Phenomenex Standard Terms & Conditions, which may be viewed at www.phenomenex.com/TermsAndConditions.

    Trademarks Phenomenex, Lux, and Kinetex are registered trademarks of Phenomenex. β-Gone, Verex, and SecurityGuard are trademarks of Phenomenex. QTRAP is a registered trademark and API 4000 is a trademark of AB SCIEX Pte. Ltd. AB SCIEX is being used under license.

    Comparative separations may not be representative of all applications.