messages - ibmpublib.boulder.ibm.com/tividd/td/job/sh19-4503-00/en_us/...access services messages....

118
NetView Access Services (MVS/ESA) IBM Messages Version 2 Release 1 SH19-4503-00

Upload: trinhkhanh

Post on 26-Jun-2018

550 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

NetView Access Services (MVS/ESA) IBM

MessagesVersion 2 Release 1

SH19-4503-00

Page 2: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages
Page 3: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

NetView Access Services (MVS/ESA) IBM

MessagesVersion 2 Release 1

SH19-4503-00

Page 4: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

Note!

Before using this information and the product it supports, be sure to read the general information under “Notices” on page v.

First Edition, December 1997

This is a major revision of, and obsoletes, SH12-5814-01. Technical changes or additions to the text and illustrations are indicated by avertical line to the left of the change.

This edition applies to Release 1 Modification Level 1 of NetView Access Services Version 2 (MVS/ESA) (Program Number 5695-036) and toall subsequent releases and modifications until otherwise indicated in new editions or technical newsletters.

Order publications through your IBM representative or the IBM branch office serving your locality. Publications are not stocked at the addressbelow.

IBM welcomes your comments. A form for readers’ comments may be provided at the back of this publication, or you may address yourcomments to the following address:

NVAS Information DevelopmentRome Tivoli LaboratoryIBM Italia S.p.A.Via Sciangai, 53

00144 Rome Italy

When you send information to IBM, you grant IBM a nonexclusive right to use or distribute the information in any way it believes appropriatewithout incurring any obligation to you.

Copyright International Business Machines Corporation 1987, 1997. All rights reserved.Note to U.S. Government Users — Documentation related to restricted rights — Use, duplication or disclosure is subject to restrictions set forthin GSA ADP Schedule Contract with IBM Corp.

Page 5: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

Contents

Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vTrademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v

About This Book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii

| What Is New in NetView Access Services Version 2.1.1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix| External Application Authorization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix| Direct Logon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix| Compact Application Selection Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix| Logmode Override . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix| REXX API Extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix

Part 1. Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Chapter 1. Operator Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Chapter 2. Administrator and User Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

Chapter 3. Batch Load Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

Part 2. Glossary and Bibliography . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95

Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97

Bibliography . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

Copyright IBM Corp. 1987, 1997 iii

Page 6: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

iv NetView Access Services Version 2 Messages

Page 7: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

Notices

References in this publication to IBM products, programs, or services do not imply that IBM intends to make these available inall countries in which IBM operates. Any reference to an IBM product, program, or service is not intended to state or imply thatonly IBM's product, program, or service may be used. Any functionally equivalent product, program, or service that does notinfringe any of IBM's intellectual property rights may be used instead of the IBM product, program, or service. Evaluation andverification of operation in conjunction with other products, except those expressly designated by IBM, are the user's responsi-bility.

IBM may have patents or pending patent applications covering subject matter in this document. The furnishing of this docu-ment does not give you any license to these patents. You can send license inquiries, in writing, to the IBM Director ofLicensing, IBM Corporation, 500 Columbus Avenue, Thornwood, NY 10594, USA.

Trademarks

The following terms, denoted by an asterisk (*) in this publication, are trademarks of IBM Corporation in the United States orother countries or both:

GDDM IBM MVS/ESANetView RACF System/370VTAM

Tivoli is a trademark of Tivoli Systems, Inc.

Other company, product, and service names which may be denoted by a double asterisk (**), may be trademarks or servicemarks of others.

Copyright IBM Corp. 1987, 1997 v

Page 8: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

vi NetView Access Services Version 2 Messages

Page 9: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

About This Book

This book contains all messages for the IBM* licensed program NetView Access Services Version 2 running under theMVS/ESA* operating system. NetView Access Services Version 2 is a member of the NetView* family of IBM licensed pro-ducts. It provides a single access control system for users of 3270-type terminal devices in a Systems Network Architecture(SNA) network and supports the management of a number of applications from a single terminal.

This book is intended for users and personnel who operate or administer NetView Access Services Version 2 in an SNAnetwork.

Unless otherwise stated, NetView Access Services in this book refers to NetView Access Services Version 2.

Copyright IBM Corp. 1987, 1997 vii

Page 10: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

viii NetView Access Services Version 2 Messages

Page 11: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

| What Is New in NetView Access Services Version 2.1.1

| Four new features have been included in NetView Access Services Version 2 Release 1 Modification Level 1. These are:

| � External Application Authorization

| � Direct Logon

| � Compact Application Selection panel

| � Logmode override.

| The set of functions available with the REXX API feature has been extended.

| External Application Authorization

| This feature enables NetView Access Services to use the application access information defined in the RACF database when| building the Application Selection Panel for each user. The NetView Access Services administrator, therefore, need no longer| create security definitions for applications in NetView Access Services as all this information will be taken from the RACF| definition for the application.

| This enhancement improves the synergy between NetView Access Services and RACF, reduces the NetView Access Services| administration time, and hence improves the usability of the NetView Access Services product.

| Direct Logon

| This feature introduces the ability to define terminals that are to be logged on to NetView Access Services without the logon| panel being displayed. This feature allows the NetView Access Services Application Selection panel to be displayed directly| when terminals are powered on.

| Compact Application Selection Panel

| This is an additional format in which to display the NetView Access Services Application Selection panel. With this new format| you can display up to 42 applications on a single screen. There is lo longer a maximum limit of 99 applications. The use of| this new format can be configured for each group.

| Logmode Override

| This feature allows the NetView Access Services administrator to explicitly specify a logmode to be used by NetView Access| Services when establishing a session with an application.

| REXX API Extensions

| Three new REXX API calls have been added to allow users to accomplish the following tasks from REXX execs:

| � Get a list of all the terminals attached to NetView Access Services, regardless of which screen they are currently dis-| playing.

| � Get a list of all the terminals that are currently displaying the NetView Access Services Logon Panel.

| � Send a message to all the terminals attached to NetView Access Services, regardless of which screen they are currently| displaying.

Copyright IBM Corp. 1987, 1997 ix

Page 12: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

x NetView Access Services Version 2 Messages

Page 13: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

Part 1. Messages

The chapters in this part contain all the messages issued by NetView Access Services.

Messages numbered below 1000 are for the operator and are written to the console or SYSPRINT, or both. Messages num-bered above 1000 are for the administrators or users and are displayed in the message lines of the NetView Access Servicespanels. Messages numbered above 5000 are batch load messages.

The format of all messages is:

EMSnnnns text

where:

EMS Component name for NetView Access Services

nnnn Message number

s Type code:

Type Code DescriptionA Immediate action is requiredD Immediate decision is requiredE Action is possibly requiredI For information purposes only. If MSGLEVEL ERROR is specified in the APPL control statement of NetView

Access Services, these are not printed. For further information, refer to NetView Access Services Version 2Customization.

text Message text explaining the error.

Copyright IBM Corp. 1987, 1997 1

Page 14: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

2 NetView Access Services Version 2 Messages

Page 15: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0100E � EMS0106E

Chapter 1. Operator Messages

EMS0100E NETVIEW ACCESS SERVICES ACTIVE SESSIONSFOR: mmmmmmmm = nnnnnnnn

Explanation: You have entered DISPLAY SESSIONS,mmmmmmmm=nnnnnnnn. This is the first message ofthe header that is sent as a reply to the DISPLAYcommand.

Messages 100, 101 and 102 are always together as aheader.

mmmmmmmm = USERID, USERLU, or RELAYLUnnnnnnnn = Actual parameter.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0101E USER SESSION APPLICATION SESSION.

Explanation: You have entered DISPLAY SESSIONS,mmmmmmmm=nnnnnnnn. This is the second messageof the header that is sent as a reply to the operatorcommand.

mmmmmmmm = USERID, USERLU, or RELAYLUnnnnnnnn = Specified value.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0102E USERID GROUPID USER LU NV/AS LU RELAYLU APPL LU.

Explanation: You have entered DISPLAY SESSIONS,mmmmmmmm=nnnnnnnn. This is the third message ofthe header that is sent as a reply to the operatorcommand.

mmmmmmmm = USERID, USERLU, or RELAYLUnnnnnnnn = Current value.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0103E ooo ppp qqq rrr sss ttt z

Explanation: The message contains the following:

ooo = User IDppp = Group IDqqq = User LU (terminal LU)rrr = NetView Access Services network namesss = Pseudo terminal name (relay LU)ttt = PLU of the applicationz = ACB type of the application. I (individual),

S (shared), U (unique), or M (multiple).

You have entered DISPLAY SESSIONS,mmmmmmmm=nnnnnnnn. This message occurs whena terminal is connected to an application session.

mmmmmmmm = USERID, USERLU, or RELAYLUnnnnnnnn = Current value.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0104E ooo ppp sss ttt z

Explanation: The message contains the following:

ooo = User IDppp = Group IDsss = Pseudo terminal name (relay LU)ttt = PLU of the applicationz = ACB type of the application. I (individual),

S (shared), U (unique), or M (multiple).

You have entered DISPLAY SESSIONS,mmmmmmmm=nnnnnnnn. This message occurs whena relay session exists but no terminal is connected tothe relay session.

mmmmmmmm = USERID or RELAYLUnnnnnnnn = Current value.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0105E ooo ppp qqq rrr

Explanation: The message contains the following:

ooo = User IDppp = Group IDqqq = User LU (terminal LU)rrr = NetView Access Services network name.

You have entered DISPLAY SESSIONS,mmmmmmmm=nnnnnnnn. This message occurs whena terminal is connected to EUS of NetView Access Ser-vices.

mmmmmmmm = USERID or USERLUnnnnnnnn = Current value.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0106E ooo ppp sss ttt z

Explanation: The message contains the following:

ooo = User IDppp = Group IDsss = Pseudo terminal name (relay LU)ttt = PLU of applicationz = ACB type of the application. I (individual),

S (shared), U (unique), or M (multiple).

You have entered DISPLAY SESSIONS,mmmmmmmm=nnnnnnnn. This message occurs whena session with an application exists, but the user is dis-connected from NetView Access Services.

mmmmmmmm = USERID or RELAYLUnnnnnnnn = Current value.

System Action: Program continues.

Operator Response: None.

Output: Console.

Copyright IBM Corp. 1987, 1997 3

Page 16: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0107E � EMS0132E

EMS0107E qqq rrr

Explanation: The message contains the following:

qqq = User LU (terminal LU)rrr = NetView Access Services network name.

You have entered DISPLAY SESSIONS,mmmmmmmm=nnnnnnnn. This message occurs whena terminal is connected to NetView Access Services anddisplays the Logon panel, but the user has not loggedon.

mmmmmmmm = USERLUnnnnnnnn = Current value.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0108E *****

Explanation: You have entered DISPLAY SESSIONS,mmmmmmmm=nnnnnnnn. This message indicates thebeginning of a new group in the display. For example, ifa user is in more than one group, this string of asterisksis used as a separator.

mmmmmmmm = USERIDnnnnnnnn = Current value.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0109E ooo ppp qqq ttt

Explanation: The message contains the following:

ooo = User IDppp = Group IDqqq = User LU (terminal LU)ttt = PLU of application. I (individual),

S (shared), U (unique), or M (multiple).

You have entered DISPLAY SESSIONS, mmm=nnn.This message occurs when a user has selected a passmode session and SIMLOGON=YES has been specifiedin the parameter input file.

mmmmmmmm = USERID or USERLUnnnnnnnn = Current value.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0110E END OF DISPLAY.

Explanation: You have entered DISPLAY SESSIONS,mmmmmmmm=nnnnnnnn, or DISPLAY USERS. Thismessage is the last message that is sent as reply to theDISPLAY command.

mmmmmmmm = USERID, USERLU, or RELAYLUnnnnnnnn = Actual value.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0120E NETVIEW ACCESS SERVICES ACTIVE USERS =mmmmmmmm.

Explanation: You have entered DISPLAY USERS.

mmmmmmmm = Number of users logged on to EUS of NetView Access Services.

This message is the first message that is sent as replyto the DISPLAY command.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0122E mmmmmmmm mmmmmmmm mmmmmmmmmmmmmmmm mmmmmmmm mmmmmmmm.

Explanation: You have entered DISPLAY USERS.This message displays active users logged on to EUS ofNetView Access Services.

mmmmmmmm = User ID.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0124E NO USERS ARE LOGGED ON.

Explanation: You have entered DISPLAY USERS.This message occurs if no user is logged on to EUS ofNetView Access Services.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0131E DISPLAY TERMINALS COMMAND REJECTED DUETO INSUFFICIENT STORAGE.

Explanation: You have entered DISPLAY TERMINALSbut there is insufficient storage.

System Action: Program continues.

Operator Response: Reenter command specifyingfewer lines to be displayed.

Output: Console.

EMS0132E NO TERMINALS FOUND FOR USERLU mmmmmmmm.

Explanation: You have entered DISPLAYTERMINALS,USERLU=mmmmmmmm where:

mmmmmmmm = VTAM* terminal ID and actual value but no VTAM terminal ID

was found.

4 NetView Access Services Version 2 Messages

Page 17: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0133E � EMS0147E

System Action: Program continues.

Operator Response: Verify entered command.

Output: Console.

EMS0133E USER mmm,nnn WAS NOT FOUND.

Explanation: You have entered CANCELmmm,nnn,SESSION=aaa but the user ID, group ID, orboth were not found.

System Action: Program continues.

Operator Response: Verify entered command.

Output: Console.

EMS0134E USER mmmmmmmm,nnnnnnnn HAS NO RELAYMODE SESSION WITH APPLICATION aaaaaaaa.

Explanation: You have entered CANCELmmmmmmmm,nnnnnnnn,SESSION=aaaaaaaa where:

mmmmmmmm = User IDnnnnnnnn = Group IDaaaaaaaa = Application system-wide name.

This message is displayed if the specified user has norelay mode session with the application.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0135E NO RELAY MODE APPLICATION FOR USERmmmmmmmm,nnnnnnnn WAS FOUND. NO SESSIONWAS CANCELED.

Explanation: You have entered CANCELmmmmmmmm,nnnnnnnn where:

mmmmmmmm = User IDnnnnnnnn = Group ID.

The user is to be logged off from all relay mode applica-tions, but no relay mode session was found.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0136E COMMAND CANNOT BE EXECUTED, BECAUSE THEMAXIMUM OF yyyyyy ACTIVE SESSIONS WOULD BEEXCEEDED.

Explanation: You have entered one of the followingcommands:

DISPLAY TERMINALS,x,yDISPLAY TERMINALS,USERLU = ttt,x,yDISPLAY TERMINALS,RELAYLU,x,yDISPLAY TERMINALS,RELAYLU = nnnnnnnn,x,yDISPLAY TERMINALS,APPLLU,x,yDISPLAY TERMINALS,APPLLU = mmmmmmmm,x,ywhere:

mmmmmmmm = PLU namennnnnnnn = Relay LU namettt = Terminal LU name

x = A (All), S (Summary), U (Used), or F (Free)

y = Maximum number of lines dis- played on the console

yyyyyy = 250 (if Y is default, or is not greater than 250), or the value of y.

System Action: Program continues.

Operator Response: Verify entered command.

Output: Console.

EMS0137E NO APPLICATION ACB WAS FOUND.

Explanation: You have entered DISPLAYSESSIONS,APPLLU but no application ACB exists.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0138E NO PSEUDO TERMINAL SESSION WAS FOUND.

Explanation: You have entered DISPLAYSESSIONS,RELAYLU but no pseudo terminal sessionexists.

System Action: Program continues.

Operator Response: Verify entered command.

Output: Console.

EMS0143E UNSUPPORTED VALUE OF nnnnnnnn IN MODULEmmmmmmmm.

Explanation: This message indicates that the modulemmmmmmmm has internal error nnnnnnnn wherennnnnnnn is one of the following:

COMMAND STATUSRIDT STATUSCOMMAND PARAMETERKEYWORD VALUE.

nnnnnnnn = Module name.

System Action: Program continues.

Operator Response: Verify entered command.

Output: Console.

EMS0147E NO sss TERMINAL FOUND.

Explanation:

sss = FREE, USED, or FREE OR USED.

You have entered DISPLAY TERMINALS,x,yyyyyybut no free or used terminal has been found.

x = A (All), U (Used), or F (Free)yyyyyy = Maximum number of lines displayed on the

console (default is 250).

System Action: Program continues.

Operator Response: Verify entered command.

Output: Console.

Chapter 1. Operator Messages 5

Page 18: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0160E � EMS0171E

EMS0160E END USER SERVICES CURRENTLY NOT ACTIVE;TRY AGAIN LATER.

Explanation: You have entered one of the followingcommands:

DISPLAY SESSIONS, mmmmmmmm = nnnnnnnnDISPLAY USERS, but the End User Service of NetViewAccess Servicesis either not completely initialized or not running.DISPLAY USERS, but the End User Serviceof NetView Access Services is either not completely ini-tialized or not running.

mmmmmmmm = USERID, USERLU, RELAYLU, or APPLLU

nnnnnnnn = Actual value.

System Action: Program continues.

Operator Response: Wait and reenter command.

Output: Console.

EMS0162E DISPLAY USERS COMMAND REJECTED DUE TOINSUFFICIENT STORAGE.

Explanation: You have entered the commandDISPLAY USERS. During processing of this commanda storage shortage occurred.

System Action: Program continues.

Operator Response: See SYSPRINT for additionalmessages.

Output: Console.

EMS0164E DISPLAY SESSIONS mmmmmmmm = nnnnnnnnREJECTED DUE TO INSUFFICIENT STORAGE.

Explanation: You have entered DISPLAYSESSIONS,mmmmmmmm=nnnnnnnn but there is insuf-ficient storage.

mmmmmmmm = USERID, USERLU, RELAYLU, or APPLLU.

System Action: Program continues.

Operator Response: Reenter command, specifyingfewer lines to be displayed.

Output: Console.

EMS0166E NO ACTIVE SESSIONS FOUND FOR mmmmmmmm =nnnnnnnn.

Explanation: You have entered DISPLAYSESSIONS,mmmmmmmm=nnnnnnnn but no sessionsare active.

mmmmmmmm = USERID, USERLU, RELAYLU, or APPLLU.

System Action: Program continues.

Operator Response: Verify entered command.

Output: Console.

EMS0168E LAST ccccccc COMMAND IS NOT COMPLETELYPROCESSED. TRY LATER.

Explanation: You have entered one of the followingcommands:

DISPLAY SESSIONS,mmmmmmmm=nnnnnnnnDISPLAY USERSDISPLAY TERMINALSDISPLAY STATISTICSREFRESHCANCEL

but the last command has not been completely proc-essed.

mmmmmmmm = USERID, USERLU, RELAYLU, or APPLLU

nnnnnnnn = Actual value.

System Action: Program continues.

Operator Response: Wait and reenter command.

Output: Console.

EMS0169E USER ooo ppp CANCELED. n SESSIONS CAN-CELED.

Explanation: This message occurs when you haveentered CANCEL ooo ppp to cancel a user’s sessions

ooo = User IDppp = Group IDn = Number of canceled sessions.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0170E n SESSIONS CANCELED

Explanation: This is the first message of the headerthat is sent as a reply to the operator commandCANCEL ooo ppp,SESSION=rrr

ooo = User IDppp = Group IDrrr = Application IDn = Number of sessions canceled.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0171E USERID GROUPID SESSION RELAY LU APPLLU

Explanation: This is the second message of theheader that is sent as a reply to the operator commandCANCEL ooo ppp,SESSION=rrr

ooo = User IDppp = Group IDrrr = Application ID.

System Action: Program continues.

Operator Response: None.

Output: Console.

6 NetView Access Services Version 2 Messages

Page 19: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0172E � EMS0178E

EMS0172E ooo ppp rrr sss ttt

Explanation: This message occurs when you havecanceled a session.

ooo = User IDppp = Group IDrrr = Application IDsss = Relay LU (pseudo terminal name)ttt = PLU of application.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0173E NETVIEW ACCESS SERVICES TERMINAL xxxxx yyyyyzzzzz

Explanation: This is the first message of the headerthat is sent as a reply to the DISPLAY TERMINALSoperator command.

If you enter DISPLAY TERMINALS,USERLU = zzzzzthen

xxxxx = SUMMARY FORyyyy = TERMINALzzzzz = Terminal LU name.

If you enter any of the following commands:

DISPLAY TERMINALSDISPLAY TERMINALS,SDISPLAY TERMINALS,ADISPLAY TERMINALS,FDISPLAY TERMINALS,U

xxxxx = LIST OFyyyyy = ALL TERMINALSzzzzz = Blank.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0174E TOTAL USED FREE

Explanation: This is the second message of theheader that is sent as a reply to any of the followingoperator commands:

DISPLAY TERMINALS,SDISPLAY TERMINALS,ADISPLAY TERMINALS,FDISPLAY TERMINALS,UDISPLAY TERMINALS,USERLU=ttt

ttt = User LU (terminal LU).

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0175E tot no1 no2

Explanation: You have entered one of the followingcommands:

DISPLAY TERMINALS,SDISPLAY TERMINALS,ADISPLAY TERMINALS,FDISPLAY TERMINALS,UDISPLAY TERMINALS,USERLU=ttt where:

ttt is the user LU (terminal LU).

tot = Total number of terminals known to NetView Access Services

no1 = Number of terminals displaying the NetView Access Services Logon panel

no2 = Number of terminals in session with NetView Access Services.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0176E USERLU USERID GROUPID STATUS

Explanation: This is the third message of the headerthat is sent as a reply to any of the following operatorcommands:

DISPLAY TERMINALS,ADISPLAY TERMINALS,FDISPLAY TERMINALS,UDISPLAY TERMINALS,USERLU=ttt

ttt is the user LU (terminal LU).

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0177E ttt ooo ppp sss

Explanation: This is the third message of the headerthat is sent as a reply to the operator commands:

DISPLAY TERMINALS,ADISPLAY TERMINALS,FDISPLAY TERMINALS,UDISPLAY TERMINALS,USERLU=ttt where:

ttt is the user LU (terminal LU)

and

ooo = User IDppp = Group IDsss = Status field, with two possible values,

FREE or USED.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0178E NETVIEW ACCESS SERVICES SESSION xxxxx yyyyyzzzzz.

Explanation: This is the first message of the headerthat is sent as a reply to any of the following operatorcommands:

If you enter DISPLAY STATISTICS

xxxxx = SUMMARY FORyyyyy = STATISTICSzzzzz = Blank.

If you enter DISPLAY SESSIONS,APPLLU = zzzzz,Sor DISPLAY SESSIONS,RELAYLU = zzzzz,S

xxxxx = SUMMARY FORyyyyy = APPLLU, or RELAYLUzzzzz = PLU of application or pseudo terminal

name.

If you enter DISPLAY SESSIONS,APPLLU = zzzzz,A

Chapter 1. Operator Messages 7

Page 20: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0179E � EMS0184E

or DISPLAY SESSIONS,RELAYLU = zzzzz,A

xxxxx = FORyyyyy = APPLLU or RELAYLUzzzzz = PLU of application or pseudo terminal

name.

If you enter DISPLAY SESSIONS,APPLLU,Sor DISPLAY SESSIONS,RELAYLU,S

xxxxx = SUMMARY FORyyyyy = ALL APPLLU-SESSIONS or RELAY

LU-SESSIONSzzzzz = Blank.

If you enter DISPLAY SESSIONS,APPLLU,Aor DISPLAY SESSIONS,RELAYLU,A

xxxxx = FORyyyyy = ALL APPLLU-SESSIONS or ALL RELAY

LU-SESSIONSzzzzz = Blank.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0179E APPL LU APPLNAM TOTAL PASSMODERELAYMODE

Explanation: This is the second message of theheader that is sent as a reply to the operator commandDISPLAY SESSIONS,APPLLU=ttt,par

ttt = PLU of applicationpar = S (summary) and A (all).

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0180E ttt rrr tot top tor

Explanation: You have entered DISPLAYSESSIONS,APPLLU=ttt,par where:

ttt = PLU of applicationpar = S (summary) and A (all)ttt = PLU of applicationrrr = Application IDtop = Number of all active pass-mode sessions of a

certain applicationtor = Number of all active relay-mode sessions of a

certain applicationtot = Total of top and tor.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0181E USERID GROUPID APPLNAM USER LU NV/ASLU RELAY LU APPL LU

Explanation: This is the message of the header thatis sent as a reply to one of the following operatorcommands:

DISPLAY SESSIONS,APPLLU=ttt,ADISPLAY SESSIONS,RELAYLU=sss,A

ttt = PLU of applicationsss = Pseudo terminal name.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0182E ooo ppp rrr ttt aaa sss qqq

Explanation: You have entered one of the followingcommands:

DISPLAY SESSIONS,APPLLU=ttt,ADISPLAY SESSIONS,RELAYLU=sss,Awhere:

ttt = PLU of applicationsss = Pseudo terminal name.

ooo = User IDppp = Group IDrrr = Application IDttt = User (terminal) LUaaa = Name of the main ACBsss = Relay LU (pseudo terminal name)qqq = PLU name.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0183E zzzzz ACB-TYPE APPLICATION SESSION

Explanation: This is the second message of theheader that is sent as a reply to the operator commandDISPLAY SESSIONS,RELAYLU....

zzzzz is blank when one of the following is entered:

DISPLAY SESSIONS,RELAYLU=sss,SDISPLAY SESSIONS,RELAYLU=sss,A

zzzzz is RELAY LU when one of the following isentered:

DISPLAY SESSIONS,RELAYLU=sss,SDISPLAY SESSIONS,RELAYLU=sss,A

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0184E sss aaaaaa nnn

Explanation: This is the message that is sent as areply to the operator command DISPLAYSESSION,RELAYLU....

sss is blank when one of the following is entered:

DISPLAY SESSIONS,RELAYLU=sss,SDISPLAY SESSIONS,RELAYLU=sss,A

sss is relay LU (pseudo terminal name) when one of thefollowing is entered:

DISPLAY SESSIONS,RELAYLU=sss,SDISPLAY SESSIONS,RELAYLU=sss,A

aaaaaaa = ACB-type (UNIQUE, SHARED, or INDIVIDUAL)

nnnnnnnn = Number of sessions of certain relay LU and ACB-type.

System Action: Program continues.

Operator Response: None.

Output: Console.

8 NetView Access Services Version 2 Messages

Page 21: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0185E � EMS0202I

EMS0185E TOTAL AMOUNT OF BUFFER USAGE: xxxxxxxxxKBYTE

Explanation: You have entered DISPLAY STATIS-TICS where:

xxxxxxxxx = Size in KB (KB equals 1024 bytes) of NetView Access Services pool and data usage.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0186E NETVIEW ACCESS SERVICES POOL AND BUFFERUSAGE STATISTICS.

Explanation: This is the third message of the headerthat is sent as a reply to the operator commandDISPLAY STATISTICS.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0187E TOTAL IN USE FREE SINGLE SIZETOTAL SIZE

Explanation: This is the fourth message of the headerthat is sent as a reply to the operator commandDISPLAY STATISTICS.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0188E (BYTE) (KBYTE)

Explanation: This is the fifth message of the headerthat is sent as a reply to the operator commandDISPLAY STATISTICS.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0189E wwwwwww no1 no2 no3 sss tot

Explanation: This message is displayed when youhave entered DISPLAY STATISTICS where:

wwwwwww is the name of pools (RPLS, NIBS, SCBS,RQES, ACBS, or BUFFERS).

no1 = Total number of the displayed itemno2 = Number of used elements of that itemno3 = Number of free elements of that itemsss = Size in bytes of an element of that itemtot = Amount in KB of that item.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0196E NUMBER OF xxxx WOULD BE GREATER THAN y.

Explanation: There are more than y terminals, appllus,or active relaylus, but the display is restricted due to thesmall value of y.

xxxx = ALL TERMINALS, USED TERMINALS, FREE TERMINALS, or

INFORMATIONAL MESSAGESy = 1 to 999999 (default is 250).

You have entered one of the following commands:

DISPLAY TERMINALS,USERLU = termid,x,y

where:

termid = Terminal namex = A (All), U (Used), or F (Free).

DISPLAY SESSIONS,RELAYLU=mmmmmmmm,x,y

where:

mmmmmmmm = Pseudo terminal namex = A (All), or S (Summary).

DISPLAY SESSIONS,APPLLU=nnnnnnnn ,x,y

where:

nnnnnnnn = PLU namex = A (All), or S (Summary).

System Action: Program continues.

Operator Response: Correct your input.

Output: Console.

EMS0200I SYSTEM APPLICATION RECORD iiiiiiii HAS BEENADDED BY nnnnnnnn.

Explanation: Administrator nnnnnnnn has defined anew application to the system.

nnnnnnnn = User ID of administratoriiiiiiii = System-internal name.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0201I SYSTEM APPLICATION RECORD iiiiiiii HAS BEENDELETED BY nnnnnnnn.

Explanation: Administrator nnnnnnnn has deleted thespecified application from the system.

nnnnnnnn = User ID of administratoriiiiiiii = System-internal name.

Users who have this as their only application will alsohave their user ID deleted.

System Action: Users currently logged on to the appli-cation may continue using it, but it can no longer beselected from the Application Selection panel afterlogoff.

Operator Response: None.

Output: SYSPRINT

EMS0202I SYSTEM APPLICATION RECORD iiiiiiii HAS BEENUPDATED BY nnnnnnnn.

Explanation: Administrator nnnnnnnn has updated thespecified application definition on the system.

nnnnnnnn = User ID of administratoriiiiiiii = System-internal name.

System Action: Users currently logged on to the appli-cation are unaffected. However, users logging on to itwill use the updated parameters.

Chapter 1. Operator Messages 9

Page 22: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0203I � EMS0213E

Operator Response: None.

Output: SYSPRINT

EMS0203I SYSTEM APPLICATION RECORD iiiiiiii uuuuuuu VIAREFRESH BY nnnnnnnn.

Explanation: Administrator nnnnnnnn has issued arefresh, which has resulted in this record beinguuuuuuu.

iiiiiiii = System internal nameuuuuuuu = ADDED, DELETED, or UPDATEDnnnnnnnn = User ID of administrator, or

OS CONSOLE name (CONSOLE).

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0205I GROUP RECORD gggggggg HAS BEEN ADDED BYnnnnnnnn.

Explanation: Administrator nnnnnnnn has added thespecified group to the system.

gggggggg = Group ID of the new groupnnnnnnnn = User ID of administrator.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0206I GROUP RECORD gggggggg HAS BEEN DELETED BYnnnnnnnn

Explanation: Administrator nnnnnnnn has deleted thespecified group from the system.

gggggggg = Group ID of the former groupnnnnnnnn = User ID of administrator.

System Action: All associated user and group applica-tions will be deleted.

Operator Response: None.

Output: SYSPRINT

EMS0207I GROUP RECORD gggggggg HAS BEEN UPDATEDBY nnnnnnnn

Explanation: Administrator nnnnnnnn has updated thespecified group definition.

gggggggg = Group ID of the updated groupnnnnnnnn = User ID of administrator.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0208I GROUP RECORD iiiiiiii uuuuuuu VIA REFRESH BYnnnnnnnn

Explanation: Administrator nnnnnnnn has issued arefresh, which has resulted in this record beinguuuuuuu.

iiiiiiii = System internal nameuuuuuuu = ADDED, DELETED, or UPDATED

nnnnnnnn = User ID of administrator, or OS CONSOLE name (CONSOLE).

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0210I APPLICATION aaaaaaaa HAS BEEN ADDED TOGROUP gggggggg BY nnnnnnnn.

Explanation: Administrator nnnnnnnn has added appli-cation aaaaaaaa to group gggggggg.

nnnnnnnn = User ID of administratoraaaaaaaa = Group application namegggggggg = Group name.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0211E APPLICATION aaaaaaaa HAS BEEN DELETED FROMGROUP gggggggg BY nnnnnnnn.

Explanation: Administrator nnnnnnnn has deletedapplication aaaaaaaa from group gggggggg.

nnnnnnnn = User ID of administratoraaaaaaaa = Group application namegggggggg = Group name.

System Action: The application is removed from theaccess list of all users who previously had access to theapplication in the group. If it was their only applicationthen their user ID is also be deleted.

Operator Response: None.

Output: SYSPRINT

EMS0212E APPLICATION aaaaaaaa OF GROUP gggggggg HASBEEN UPDATED BY nnnnnnnn.

Explanation: Administrator nnnnnnnn has updated thedefinition for the specified application within the group.

nnnnnnnn = User ID of administratoraaaaaaaa = Group application namegggggggg = Group name.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0213E APPLICATION iiiiiiii uuuuuuu, VIA REFRESH, TOGROUP gggggggg BY nnnnnnnn.

Explanation: Administrator nnnnnnnn has issued arefresh, which has resulted in an application being in anapplication being uuuuuuu.

iiiiiiii = System-internal nameuuuuuuu = ADDED, DELETED, or UPDATEDgggggggg = Group namennnnnnnn = User ID of administrator, or

OS CONSOLE name (CONSOLE).

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

10 NetView Access Services Version 2 Messages

Page 23: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0220E � EMS0232E

EMS0220E USER uuuuuuuu HAS BEEN ADDED TO APPLICA-TION aaaaaaaa IN GROUP gggggggg BY nnnnnnnn.

Explanation: Administrator nnnnnnnn has added useruuuuuuuu access to the specified application within thegroup. The user ID may or may not have been previ-ously defined to this group.

nnnnnnnn = User ID of administratoraaaaaaaa = Group application namegggggggg = Group nameuuuuuuuu = User ID of the user.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0221E USER uuuuuuuu HAS BEEN DELETED FROM APPLI-CATION aaaaaaaa IN GROUP gggggggg BYnnnnnnnn.

Explanation: Administrator nnnnnnnn has removeduser uuuuuuuu from the access list for applicationaaaaaaaa within the group.

nnnnnnnn = User ID of administratoraaaaaaaa = Group application namegggggggg = Group nameuuuuuuuu = User ID of the user.

System Action: If this was the user’s only applicationthen the user ID will be deleted.

Operator Response: None.

Output: SYSPRINT

EMS0222E USER uuuuuuuu FOR APPLICATION aaaaaaaa INGROUP gggggggg HAS BEEN UPDATED BYnnnnnnnn.

Explanation: Administrator nnnnnnnn has updated theaccess parameters for user uuuuuuuu to applicationaaaaaaaa within the group. This message is also givenwhen users update their own application access param-eters.

nnnnnnnn = User ID of the person performing the update

aaaaaaaa = Group application namegggggggg = Group nameuuuuuuuu = User ID of the user.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0227E BROADCAST AUTHORIZATION FOR USER uuuuuuuuHAS BEEN ADDED BY nnnnnnnn.

Explanation: System administrator nnnnnnnn hasauthorized user uuuuuuuu to use the Broadcast Selec-tively function.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0228E BROADCAST AUTHORIZATION FOR USER uuuuuuuuHAS BEEN DELETED BY nnnnnnnn.

Explanation: Authorization for user uuuuuuuu to usethe Broadcast Selectively function has been revoked bysystem administrator nnnnnnnn.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0229E BROADCAST AUTHORIZATION FOR USER uuuuuuuuHAS BEEN UPDATED BY nnnnnnnn.

Explanation: Authorization for user uuuuuuuu to usethe Broadcast Selectively function has been updated bysystem administrator nnnnnnnn.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0230E USER uuuuuuuu HAS BEEN ADDED AS SYSTEMADMINISTRATOR BY nnnnnnnn.

Explanation: System administrator nnnnnnnn hasgiven user uuuuuuuu the authority of system adminis-trator.

nnnnnnnn = User ID of the administrator allowing access

uuuuuuuu = User ID of the new system admin- istrator.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0231E USER uuuuuuuu HAS BEEN DELETED AS SYSTEMADMINISTRATOR BY nnnnnnnn.

Explanation: System administrator nnnnnnnn hasrevoked user’s uuuuuuuu authorization as systemadministrator.

nnnnnnnn = User ID of the administrator revoking access

uuuuuuuu = User ID of the former system administrator.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0232E USER uuuuuuuu HAS BEEN UPDATED AS SYSTEMADMINISTRATOR BY aaaaaaaa.

Explanation: System administrator aaaaaaaa hasissued an update command for the system administratoruuuuuuuu.

System Action: Only the Admin Exit Data may bechanged. The exact action is determined by yourinstallation-wide exit. Program continues in any case.

Operator Response: None.

Output: SYSPRINT

Chapter 1. Operator Messages 11

Page 24: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0233E � EMS0240E

EMS0233E USER uuuuuuuu HAS BEEN ADDED AS ADMINIS-TRATOR FOR GROUP gggggggg BY nnnnnnnn.

Explanation: Administrator nnnnnnnn has allowed useruuuuuuuu authorization as administrator for groupgggggggg.

nnnnnnnn = User ID of the administrator allowing access

uuuuuuuu = User ID of the new group administrator

gggggggg = Group for which the user has been allowed authorization.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0234E USER uuuuuuuu HAS BEEN DELETED AS ADMINIS-TRATOR FOR GROUP gggggggg BY nnnnnnnn.

Explanation: Administrator nnnnnnnn has revokeduser’s uuuuuuuu authorization as administrator for groupgggggggg.

nnnnnnnn = User ID of the administrator revoking access

uuuuuuuu = User ID of the former group administrator

gggggggg = Group from which the user has been revoked.

System Action: The user is no longer an administratorof the group.

Operator Response: None.

Output: SYSPRINT

EMS0235E USER uuuuuuuu HAS BEEN UPDATED AS ADMINIS-TRATOR FOR GROUP gggggggg BY aaaaaaaa.

Explanation: System administrator aaaaaaaa hasissued an update command for the group administratoruuuuuuuu of group gggggggg.

System Action: Only the Admin Exit Data may bechanged. The exact action is determined by yourinstallation-wide exit. Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0236E THE CNMNETV ROUTINE IS NOT AVAILABLE.

Explanation: NetView Access Services tried to loadthe CNMNETV routine, but it is not available.

System Action: Program continues. The NetViewAlert Interface is not established.

Operator Response: Check the installation of theCNMNETV routine supplied with NetView.

Output: Console.

EMS0237E ADDRESSING OF THE NETVIEW ALERT INTERFACEFAILED. RC = nn.

Explanation: NetView Access Services called theCNMNETV routine with request type 1 to make sure thatthe NetView Subsystem is available, and received anegative response.

Return Code Description24 NetView Subsystem is not active.28 This NetView does not support user request.

System Action: Program continues. An Alert cannotbe sent to NetView.

Operator Response: None.

Output: Console.

EMS0238E SENDING OF AN ALERT TO NETVIEW FAILED. RC =nn.

Explanation: NetView Access Services called theCNMNETV routine with request type X'12' to send analert to NetView and received a negative response.

Return Code Description20 Invalid request type.22 User program not executing in primary addressing

mode.23 User program is not authorized.24 NetView Subsystem is not active.26 Receiver program not defined.28 This NetView does not support user request.32 No storage available.33 Invalid buffer length.34 The NMVT buffer length exceeds 512 bytes.35 The receiver buffer queue is full.36 ESTAE recovery cannot be established as

requested.40 Invalid sender_id or receiver_id.90 Process error occurred.

System Action: Program continues.

Operator Response: Depends on the Return Code.

Output: Console.

EMS0239E UNEXPECTED RC = nn RECEIVED FROM NETVIEW.REQUEST TYPE = mm.

Explanation: A return code was received from theCNMNETV Interface Routine, which is not described inthe Interface documents.

System Action: Program continues.

Operator Response: Contact IBM service personnel.

Output: Console.

EMS0240E BIND USER DATA HAS BEEN ADDED FOR iiiiiiii BYnnnnnnnn.

Explanation: Administrator nnnnnnnn has definedsome new BIND user data for application iiiiiiii.

nnnnnnnn = User ID of the administratoriiiiiiii = System-internal name.

System Action: This data is passed to the applicationat logon.

Operator Response: None.

Output: SYSPRINT

12 NetView Access Services Version 2 Messages

Page 25: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0241E � EMS0252E

EMS0241E BIND USER DATA HAS BEEN DELETED FOR iiiiiiii BYnnnnnnnn.

Explanation: Administrator nnnnnnnn has deleted theBIND user data for application iiiiiiii.

nnnnnnnn = User ID of the administratoriiiiiiii = System-internal name.

System Action: From now on no data is passed to theapplication at logon.

Operator Response: None.

Output: SYSPRINT

EMS0242E BIND USER DATA HAS BEEN UPDATED FOR iiiiiiii BYnnnnnnnn.

Explanation: Administrator nnnnnnnn has updated theBIND user data for application iiiiiiii.

nnnnnnnn = User ID of the administratoriiiiiiii = System-internal name.

System Action: This new data is passed to the appli-cation at logon.

Operator Response: None.

Output: SYSPRINT

EMS0243E BIND USER DATA uuuuuuu, VIA REFRESH, FOR iiiiiii,BY nnnnnnnn.

Explanation: Administrator nnnnnnnn has issued arefresh, which has resulted in BIND user data beinguuuuuuu for application iiiiiii, for group gggggggg.

uuuuuuu = ADDED, DELETED, or UPDATEDiiiiiiii = System-internal namennnnnnnn = User ID of administrator,

OS CONSOLE name (CONSOLE).

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0244I BACKUP APPLICATION bbbbbbbb FOR APPLICA-TION aaaaaaaa IS NOT DEFINED.

Explanation: A backup application for an applicationhas been specified, but the backup application is notdefined to NetView Access Services.

bbbbbbbb = Backup application nameaaaaaaaa = Name of application to be backed

up.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0245I FALLBACK PROCESSING FOR APPLICATIONaaaaaaaa WAS INTERRUPTED.

Explanation: A user tried to request a session withapplication aaaaaaaa that is not available.

System Action: Fallback processing is interrupted dueto detection of an inconsistency in the backup ring.

Operator Response: None.

Output: Console.

EMS0250I SESSION: PLU = pppppppp USER ID = uuuuuuuuGROUP ID = gggggggg TERM LU = tttttttt A/C NO =aaaaaaaa SLU = ssssssss FLAGS = am.

Explanation: This message is issued at session estab-lishment and session termination, for sessions with aNetView Access Services application.

The accounting exit EMSENPME is also called withthese same values:

pppppppp = ACB name of application with which session has been bound or unbound.

uuuuuuuu = User ID of user creating the session.

gggggggg = Group ID of user creating the session.

tttttttt = Physical terminal at which the user requested the session.

aaaaaaaa = Account number of user creating the session.

ssssssss = Pseudo terminal used to bind the session. Blank for pass mode.

am = Action and mode where:

a = C for connect, D for disconnect, T for NetView Access Services

termination.m = R for relay, or P for pass.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0251E INVALID COMBINATION DETECTED: RESID = rrrrrr ,WHTRCVD =ww , NVAS-FUNCTION STATUS =s INMODULE mmmmmmmm.

Explanation:

rrrrrr = Resource IDww = What received codes = NetView Access Services function

status.mmmmmmmm = Module name.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0252E BULLETIN BOARD: MODULE mmmmmmmm,MEMBER nnnn IS EMPTY.

Explanation: A member in a Bulletin Board module isempty.

mmmmmmmm = Module namennn = Member name.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

Chapter 1. Operator Messages 13

Page 26: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0253E � EMS0372E

EMS0253E SUBTASK EMSEVQH1 ABENDED.

Explanation: A subtask in EMSEVQH1 has abnormallyterminated.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0301E INVALID PARAMETER SUPPLIED nnnnnnnn.

Explanation: The macro processor was invoked with azero address for at least one of the parameters. Themacro request has been rejected.

nnnnnnnn = Name of the NetView Access Services macro parameter with zero address.

System Action: Program continues.

Operator Response: Change the invalid parameterand run the program again.

Output: Console.

EMS0302E INVALID MACRO SUPPLIED, ID = xx.

Explanation: The macro processor was invoked withan unrecognizable macro ID. The macro request hasbeen rejected.

xx = Macro ID used to invoke the macro processor of NetView Access Services.

System Action: Program continues.

Operator Response: Check the value of the macro IDagainst the assembler expansion of the macro. Checkcontents of register 1.

Output: Console.

EMS0304E INVALID SCB RETURNED.

Explanation: The resource ID field specified in themacro invocation does not match that in the sessioncontrol block (SCB). The macro request has beenrejected. The macro request failed.

System Action: Program continues.

Operator Response: Ensure that the correct resourceID is entered in the macro call.

Output: Console.

EMS0307E EMS0310E INVALID BUFFER IN CHAIN.

Explanation: It was attempted to return an invalidbuffer to the pool of free buffers.

System Action: Reject request—continue.

Operator Response: Check for invalid bufferaddresses in the macro call.

Output: Console.

EMS0311E ADDRESS = aaaaaaaa , HEADER = hhhh hhhhhhhhhhhh hhhhhhhh hhhhhhhhh

Explanation: This message follows messageEMS0310E. The storage area at address aaaaaaaa isnot an active buffer. The first bytes of this storage area(the buffer header) are output in hexadecimal form inthe format hhhh hhhh hhhhhhhh hhhhhhhh hhhhhhhh.

System Action: Program continues.

Operator Response: Perform problem determinationprocedure.

Output: Console and SYSPRINT.

EMS0312E BUFFER POOL POSSIBLY CORRUPTED.

Explanation: When performing an EMSGBUF request,NetView Access Services detected that part of storagewas overlaid. Subsequent unpredictable results mightoccur.

System Action: Program continues.

Operator Response: Perform problem determinationprocedure.

Output: Console and SYSPRINT.

EMS0320E INVALID REQUEST yyyyyyyy.

Explanation: The parameter list passed to the controlblock handler module contained an invalid request type.Therefore, the module failed to perform the given func-tion.

yyyyyyyy = Invalid request type specified.

System Action: Program continues.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0340E INVALID yyy CONTROL BLOCK.

Explanation: A control block passed to the modulewas invalid. That is, an address passed to the modulefor the control block was erroneous. The module cannotperform its function.

yyy = Name of the control block for which an invalid address was given (SCB, ACB, RPL, NIB, or RQE)

System Action: Program continues.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0372E ACB xxxxxxxx COULD NOT BE OPENED - ACBERROR FIELD = Xnn.

Explanation: A VTAM OPEN ACB request ended withan error.

nn = Contents of the ACB’s ERROR fieldxxxxxxxx = Name of the ACB.

System Action: Program continues.

Operator Response: See VTAM error codes in VTAM:Programming. Correct the problem.

Output: Console.

14 NetView Access Services Version 2 Messages

Page 27: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0373E � EMS0401E

EMS0373E INSTALLATION-WIDE EXIT EMSEPRPS DID NOT SETTHE FIELD PRPDOCLS

Explanation: A print request for the system printer isrejected because the installation-wide exit routineEMSEPRPS did not return an output class for thesystem printer.

System Action: Print request terminated.

Operator Response: The exit EMSEPRPS should beextended to set the output class.

Output: Console.

EMS0374E PRINTER pppppppp INTERVENTION REQUIRED.

Explanation: A send request to printer pppppppp wasrejected by the printer with a sense code indicating thatintervention is required (for example, out of paper, or apower-off condition).

System Action: Program continues.

Operator Response: Determine the interventionrequired and rectify.

Output: Console.

EMS0375E BUFFER PROCESSING ERROR IN MODULEEMSEPEXI, RC=rr

Explanation: rr is the return code issued byEMSEPEXI. A return code of 04 indicates anEMSGBUF failure and a return code of 08 indicates anEMSFBUF failure.

System Action: Program continues.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0376E BUFFER FORMATTING ERROR IN MODULEEMSEPBUF, RC=rr

Explanation: rr is the return code issued byEMSEPBUF.

System Action: Resources deallocated.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0377E EMSEDMF ERROR FOR DYNALLOC PROCESSINGOCCURRED, RC=rr

Explanation: rr is the return code issued byEMSEDMF.

System Action: Resources deallocated.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0378E VSAM PROCESSING ERROR OCCURRED

Explanation: EMSEPVSM returned an unexpectedreturn code for SRTU maintenance.

System Action: Resources deallocated.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0379E LOCAL SEND ERROR OCCURRED FOR RESID = rrrrrr

Explanation: A local send error occurred for theresource identified by rrrrrr.

System Action: Resources deallocated.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0380E NO FREE ELEMENTS IN yyy POOL.

Explanation: The control block handling routinebranched to the control block formatting routine to getmore elements in the yyy control block pool, but it failedto augment the yyy pool. The control block handler thusfails to attain the requested control block.

yyy = Control block name (SCB, ACB, RPL, NIB, or RQE).

System Action: Program continues.

Operator Response: Check for additional messages inlog. If they indicate a GETMAIN failure then increaseREGION size and restart NetView Access Services.Otherwise perform NetView Access Services problemdetermination procedure.

Output: Console.

EMS0400E ALLOCATE REQUEST FAILED IN MODULEmmmmmmmm.

Explanation: mmmmm is the module that has tried theALLOCATE. This is a general error message issuedwhen a module has an ALLOCATE error.

System Action: The function is canceled and anappropriate message is sent to the user.

Operator Response: Perform the problem determi-nation procedure.

Output: Console.

EMS0401E DEALLOCATE MACRO FAILED IN MODULEmmmmmmmm.

Explanation: mmmmm is the module that tried theDEALLOCATE. This is a general error message issuedwhen a module has a DEALLOCATE error.

System Action: The function is canceled and anappropriate message is sent to the user.

Operator Response: Perform the problem determi-nation procedures.

Output: Console.

Chapter 1. Operator Messages 15

Page 28: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0405E � EMS0415E

EMS0405E PROBLEM WITH INTERNAL CLOCK.

Explanation: Internal clock damaged.

System Action: Program continues, but the time-outfunction no longer works.

Operator Response: Contact your IBM systemsupport representative.

Output: Console.

EMS0406I THE FNMNSI ROUTINE IS NOT AVAILABLE.

Explanation: NetView Access Services tried to loadthe FNMNSI routine, but it was not available.

System Action: Program continues. The NetViewSynergy Interface is not established. No session corre-lation information is sent to NetView PerformanceMonitor.

Operator Response: Check the installation of theFNMNSI routine supplied with NetView PerformanceMonitor.

Output: Console.

EMS0407I RETRY LIMIT EXCEEDED FOR ATTACHINGSUBTASK EMSCNISS

Explanation: The NetView Synergy Interface is notestablished. No Session correlation information is sentto NetView Performance Monitor.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0408I THE NSI IS ESTABLISHED.

Explanation: NetView Access Services is connected tothe NetView Synergy Interface. Session correlationinformation can be sent to NetView PerformanceMonitor.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0409I THE NSI CONNECTION COULD NOT BE ESTAB-LISHED, RC=xx, REASON=yy.

Explanation: For a list of FNMNSI return and reasoncodes see NetView Performance Monitor Installationand Customization.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0410I THE NSI CONNECTION IS TERMINATED.

Explanation: The connection to the NetView synergyinterface is terminated. No session correlation informa-tion is sent to NetView Performance Monitor.

System Action: Program continues. If NetViewAccess Services does not terminate, another attempt ismade to establish connection to the NetView SynergyInterface.

Operator Response: None.

Output: Console.

EMS0411E INVALID EVENT TYPE Xnn SPECIFIED FOR EMSNPMMACRO.

Explanation: The EMSNPM macro was invoked withan invalid type parameter value.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0412I SENDING EVENT WAS NOT SUCCESSFUL, RC=xx,REASON=yy

Explanation: For a list of FNMNSI return and reasoncodes, refer to NetView Performance Monitor Installationand Customization.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0413I DISCONNECTING FROM NSI FAILED, RC=xx,REASON=yy.

Explanation: For a list of FNMNSI return and reasoncodes refer to NetView Performance Monitor Installationand Customization.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0414E UNKNOWN RETURN/REASON CODE RECEIVEDFROM NSI, RC=xx, REASON=yy.

Explanation: An unknown return code has beenreceived from the NetView Synergy Interface moduleFNMNSI. For a list of FNMNSI return and reason codesrefer to NetView Performance Monitor Installation andCustomization.

System Action: Program continues.

Operator Response: Contact the IBM system support.

Output: Console.

EMS0415E mmmmmmmm FAILED, RC = xx, RSNC = yy, EVENT =zz, CALLING MODULE = nnnnnnnn.

Explanation: This is a general error message that isissued when a NetView Access Services module relatedto the NetView Synergy Interface fails.

mmmmmmmm = Module that has failedxx = Return codeyy = Reason code

16 NetView Access Services Version 2 Messages

Page 29: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0428E � EMS0433E

zz = Eventnnnnnnnn = Calling module name.

The following are the return codes from moduleEMSENISE:

X'04' Event not validX'08' EMSNPM macro failedX'0C' Resource ID Table (RIDT) entry not validX'10' Server RIDT, Active Routing Table (ART)

entry missingX'14' Terminal RIDT incorrectX'16' Server RIDT, terminal missingX'18' Terminal RIDT incorrectX'20' Invalid event typeX'24' RIDT status invalid for NSI.

System Action: The event is not sent to the NetViewSynergy Interface.

Operator Response: Perform problem determinationprocedure.

Output: Console.

| EMS0428E NO ATTRIBUTE FOUND AT POSITION xx/yy IN| PANEL pppp FOR LANGUAGE l – DEFINITION| IGNORED.

| Explanation: The panel indicated contains an error in| the number of lines description, and it cannot be proc-| essed correctly.

| System Action: Program continues.

| Operator Response: Edit the panel source to remove| the error.

| Output: Console.

EMS0429E SPW VARIABLE DETECTED IN CLDST/PASS DATA.

Explanation: An &SPW variable has been passed inthe BIND user data for an application. This is notallowed.

System Action: Internal error message displayed onthe user’s terminal. Program continues.

Operator Response: Set up the BIND user datawithout the &SPW variable.

Output: Console.

EMS0430E mmmmmmmm FAILED, RC = nn.

Explanation: This is a general error message issuedwhen a module fails.

mmmmmmmm = Module that has failednn = Return code.

System Action: Depending on error, processing con-tinues or function may be canceled.

Operator Response: Perform the problem determi-nation procedure.

Output: Console.

EMS0431E I/O ERROR OCCURRED IN MODULE xxxxxxxx ON ffffREASON=rr DDNAME=dd.

Explanation: An input or output error has occurred.

xxxxxxxx = Name of module issuing message.ffff = Function, READ or FIND.rr = Reason code.

For READ this is a short message of theSYNAD format.For FIND this is the FIND return code.

dd = DDNAME on which the error is to be terminated.

System Action: NetView Access Services terminates.

Operator Response: If the module name isEMSESTR, then the error is in the definition of the panellibrary associated with the DDNAME. Refer to the infor-mation on panel libraries in NetView Access ServicesVersion 2 Customization. If the module name is notEMSESTR and the reason is not clear, then perform theproblem determination procedure.

Output: Console.

EMS0432I DEFAULT USED FOR KEY nn IN PANEL ppppppLANGUAGE= l.

Explanation: A PF key number in the PFKEYS line ofthe panel pppppp has been incorrectly coded. It mustbe a number between 01 and 24. The panel librarybeing processed is identified by l.

System Action: The function assigned to the key wascorrect, so the default key for the function is used. Thedefault key for each function is:

H (HELP) PF1L (LANG) PF2D (DISC) PF3E (END) PF3Q (LOGOFF) PF3R (KEYS) PF4U (UPDATE) PF4B (BACKW) PF7F (FORW) PF8Q (LOGOFF) PF12

Operator Response: Correct the PFKEYS line of thepanel for the specified language.

Output: Console.

EMS0433E PANEL ID NOT EQUAL TO MEMBER NAMEPANEL=pppppp LANGUAGE= l.

Explanation: An invalid panel identifier was found inpanel pppppp. The language in question is identified byl.

System Action: EUS terminates.

Operator Response: The panel ID is found in posi-tions 2 through 9 of the first input line of the panel (thisexcludes comment lines). It must be the same as themember name. The byte immediately preceding it (posi-tion 1) must be the character identifying a protectedinput field. It can be displayable or nondisplayable; bydefault it is nondisplayable.

Output: Console.

Chapter 1. Operator Messages 17

Page 30: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0434E � EMS0450E

EMS0434E ONLY nn PANEL LINES SPECIFIED IN PANEL ppppppFOR LANGUAGE l.

Explanation: The fixed panels (non-help panels) mustdefine 24 panel definition lines. This excludescomment, HELPNR, and PFKEYS lines. If more than24 are defined, then the remaining lines are treated ascomment lines. If fewer are specified, this is an error.

System Action: EUS terminates.

Operator Response: Locate panel pppppp for lan-guage l, and ensure that it contains exactly 24 noncom-ment lines before the first HELPNR or PFKEYSdefinition.

Output: Console.

EMS0435E PANEL pppppp NOT FOUND FOR LANGUAGE l

Explanation: The panel pppppp could not be found inthe library for language l.

System Action: EUS terminates.

Operator Response: If the panel name is of the formEMSPnn, then it is a fixed panel. These must alwaysbe present. If the panel name is of the formEMSHnnnn, then it is a help panel. These are identifiedin the HELPNR line of the fixed panels. Either correctthe fixed panel requesting the help panel, or supply thehelp panel.

Output: Console.

EMS0436E OPEN FAILED FOR PANEL LIBRARY l.

Explanation: The DCB for EMSPANl (where l is thelanguage number) failed to open.

System Action: EUS terminates.

Operator Response: Determine the cause of the errorby looking for operating system messages.

Output: Console.

EMS0437E SUPERFLUOUS HELP PANEL LINES IGNORED INpppppp FOR LANGUAGE l.

Explanation: Help panels may contain up to 24 paneldefinition lines (that is, noncomment lines). HELPNRand PFKEYS lines are not allowed. If more than 24noncomment lines are found, the extra lines are ignored.

System Action: Program continues, only the first 24lines are used.

Operator Response: Edit the panel source to removethe extra lines.

Output: Console.

EMS0438E PF KEYS FOR LANGUAGE l DO NOT MATCH THOSEOF LANGUAGE 1, PANEL pppppp.

Explanation: The PFKEYS lines used in the panelsource for language 1 apply to all languages. A checkis made that the PFKEYS used in the other languagesmatch those of language 1. If they do not, then thisinformation message is issued.

System Action: Program continues, the PFKEYS usedin language l are ignored.

Operator Response: Ensure that the PFKEYS defi-nitions in panel pppppp are the same in each language

used. Also ensure that the prompting text matches theactual PF-key usage.

Output: Console.

EMS0439E x KEY IS INVALID FOR PANEL pppppp LANGUAGE= lPANEL=pppppp.

Explanation: An error was detected whilst processingthe PFKEYS definitions for panel pppppp in language l.The one-character function-key value x is either com-pletely unrecognized as a help key function, or it is notavailable for this panel. For example, B (page back-wards) is not available on all panels.

System Action: Program continues, the PF keyremains unused.

Operator Response: Correct the PFKEYS definitionsin panel pppppp for language l. Ensure that theprompting text matches the actual PF-key usage.

Output: Console.

| EMS0440E GETMAIN ERROR FOR nnnnnn BYTES IN MODULE| mmmmmm.

| Explanation: nnnnnn is the number of bytes that the| module has tried to GETMAIN. mmmmmm is a general| error message issued when a module has a GETMAIN| error.

| System Action: Function is canceled and an appro-| priate message is sent to the user.

| Operator Response: It is possible that not enough| storage has been allocated to NetView Access Services.| Increase the region size for NetView Access Services.

| Output: Console.

EMS0449E ADDRESS = xx LENGTH = yy SUBPOOL = zz EVENT= ee DATA = dd.

Explanation: This message is displayed followingmessage EMS0450E when a FREEMAIN error occurs inthe selective broadcast function. The message providesadditional error information.

xx = Addressyy = Lengthzz = Subpoolee = Event typedd = Data.

System Action: Program continues.

Operator Response: Analyze the printout data todetermine the cause of the error.

Output: Console.

| EMS0450E FREEMAIN ERROR IN MODULE mmmmmm.

| Explanation: mmmmmm is the module that has issued| the FREEMAIN macro. This is a general error message| issued when a module has a FREEMAIN error.

| System Action: Program continues.

| Operator Response: Check for additional messages| issued by the operating system. Perform the problem| determination procedure.

| Output: Console.

18 NetView Access Services Version 2 Messages

Page 31: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0451E � EMS0465E

EMS0451E INSUFFICIENT MESSAGE LINES DEFINED IN PANELpppppppp LANGUAGE= l.

Explanation: Each of the fixed panels must containtwo output fields bearing the names Z1 and Z2. Theseare the two lines to be used for displaying messages. Ifeither is missing, this message is issued.

pppppppp = Panel namel = Language being processed.

System Action: EUS terminates.

Operator Response: Correct the definition of panelpppppp for language l. The message EMS0453E, justprior to this message, indicates exactly which field ismissing.

Output: Console.

EMS0452E FIELD LENGTH IN PANEL pppppppp REDUCED FROMnn TO 80, LANGUAGE= l.

Explanation: The length of a field on the panels isdetermined as the space between two attributes.However, there is a maximum limit of 80 bytes for inputand output fields (that is, those beginning with aNetView Access Services field name).

System Action: The length of the field is set to 80 andprocessing continues.

pppppppp = Panel namenn = Lengthl = Language being processed

Operator Response: Correct the definition of panelpppppp for language l.

Output: Console.

EMS0453E FIELD xx IS MISSING FROM PANEL pppppp LAN-GUAGE=l.

Explanation: The input or output field named xx ismissing from panel pppppp. The language is identifiedby l.

System Action: For output fields, processing con-tinues without the field. The message lines Z1 and Z2are an exception to this, NetView Access Services ter-minates if they are not found. For input fields, NetViewAccess Services always terminates.

Operator Response: Correct the definition of panelpppppp for language l. Ensure that every field name ispreceded by an attribute byte. For further information,refer to the guidelines for modifying NetView AccessServices panels in NetView Access Services Version 2Customization.

Output: Console.

EMS0454E LANGUAGE n IS NOT IMPLEMENTED.

Explanation: The message table or the panels for lan-guage n are missing.

System Action: Program continues.

Operator Response: Check the message table orpanels for language n.

Output: Console.

EMS0455E EMSSENDD FOR RESOURCE ID rrrrrrrr IN MODULEmmmmmmmm FAILED.

Explanation: The send to the specified resource IDcould not be performed.

rrrrrrrr = Resource IDmmmmm = Module name.

System Action: Depending on the module, the Logonpanel is sent and all applications remain active, or thecorresponding application is deallocated.

Operator Response: Perform the problem determi-nation procedure.

Output: Console.

EMS0456E TIME MACRO FAILED IN MODULE mmmmmmmm.RC=xx.

Explanation: The time macro has failed in a module.

mmmmmmmm = Module namexx = Return code.

System Action: The requesting user is disconnected.

Operator Response: None.

Output: Console.

EMS0457E EMSREQTS FOR RESOURCE ID rrrrrrrr IN MODULEmmmmmmmm FAILED.

Explanation: The request to send processing to thespecified resource ID could not be performed.

rrrrrrrr = Resource IDmmmmmmmm = Module name.

System Action: Depending on the module, either theLogon panel is displayed and all sessions remain active,or the corresponding application is deallocated.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0458E LOOPING TRANSACTION DETECTED FORLU=xxxxxxxx RESOURCE=rrrrrrrr. SESSION WILL BEDROPPED.

Explanation: A looping transaction has been detected.

xxxxxxxx = LU name.rrrrrrrr = Resource ID

System Action: NetView Access Services drops thesession.

Operator Response: None.

Output: Console.

EMS0465E xxxxxxxx MACRO ERROR IN MODULE mmmmmmmm.RC = yy.

Explanation: Macro xxxxxxxx (for example, GETMAINor FREEMAIN, EMSGBUF or EMSFBUF) was issued onbehalf of module mmmmmmmm and completed with areturn code that was not zero.

mmmmmmmm = Module nameyy = Return code.

Chapter 1. Operator Messages 19

Page 32: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0480E � EMS0492E

System Action: If GETMAIN or EMSGBUF macro, thefunction is canceled. If FREEMAIN or EMSFBUFmacro, the program continues.

Operator Response: Perform problem determinationprocedure.

Output: Console and SYSPRINT.

EMS0480E ACCESS CONTROL WAS FAILED BY THE INSTALLA-TION EXIT ROUTINE.

Explanation: Access was failed by the installation exitroutine. RC = 18 has been received from the installa-tion security manager.

System Action: The user logon request is rejected.

Operator Response: Check installation exit routine.

Output: Console.

EMS0481E LOAD MODULE NOT APF AUTHORIZED.

Explanation: If RACF* is used, all load modules mustbe loaded from an APF authorized library.

System Action: The user logon request is rejected.

Operator Response: Ensure that the NetView AccessServices load modules are placed in an APF authorizedlibrary, or ensure that the sample logon authorizationexit EMSELGNX and administration exit EMSEADEXexits are not used.

Output: Console.

EMS0482E SYSTEM AUTHORIZATION FACILITY NOT ACTIVE.

Explanation: The interface to the installation securitymanager is not active.

System Action: The user logon request is rejected.

Operator Response: Activate System AuthorizationFacility. If not required, a dummy version ofEMSELGNX should be used.

Output: Console.

EMS0483E ERROR/HELP DEFINITION FOR FIELD xx ON PANELpppppp FOR LANGUAGE= l IS MISSING.

Explanation: The error or help definition for fieldnamed xx is missing from panel pppppp. The languageis identified by l.

System Action: NetView Access Services terminates ifthey are not found.

Operator Response: Correct the definition of panelpppppp for language l. For further information, refer tothe guidelines for modifying NetView Access Servicespanels in NetView Access Services Version 2Customization.

Output: Console.

EMS0484E ACCESS CONTROL IS NOT ACTIVE.

Explanation: The installation security manager is notactive.

System Action: The user logon request is rejected.

Operator Response: Check the access controlroutine.

Output: Console.

EMS0488E SECURITY MACRO PARAMETERS INVALID.

Explanation: Security macro parameters are invalid.

System Action: The user logon request is rejected.

Operator Response: Check the macro call in thelogon exit routine.

Output: Console.

EMS0489E INVALID CONTROL EVENT eeeeeeee IN MODULEmmmmmmmm.

Explanation: An invalid event that controls the internalprocessing occurred in specified module.

eeeeeeee = Invalid control eventmmmmmmmm = Module name.

System Action: Processing continues.

Operator Response: Perform problem determinationprocedure.

Output: Console and SYSPRINT.

EMS0490E INVALID COMMAND RECEIVED IN MODULEEMSEJSEL.

Explanation: An invalid command has been passed tothis module.

System Action: Program continues. An errormessage is sent to the user’s terminal.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0491E INVALID RETURN FROM EMSEINFO.

Explanation: An error has been detected on returningfrom module EMSEINFO.

System Action: Program continues.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0492E SESSION HAS BEEN DROPPED FOR LU= xxxxxxxxRESOURCE=rrrrrrrr.

Explanation: The session with an LU has beendropped.

xxxxxxxx = LU name.rrrrrrrr = Resource ID

System Action: Processing continues.

Operator Response: None.

Output: Console.

20 NetView Access Services Version 2 Messages

Page 33: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0493E � EMS0500E

EMS0493E SYSTEM APPLICATION nnnnnnnn NOT FOUND INSRTS.

Explanation: No entry for the system-internal namewas found in a search through the SRTS.

System Action: Program continues. An errormessage is sent to the user’s terminal.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0494E GENERATION OF SYSTEM DUMP FAILED. RC= yyREASON:xxxxxxxx.

Explanation: A NetView Access Services systemdump request (SDUMP) ended with a negative systemresponse. Refer to Virtual Machine/System ProductGroup Control System Command and Macro Referencefor a detailed description of return and reason codes.

System Action: Program continues.

Operator Response: Perform action in accordancewith the issued reason code.

Output: Console.

EMS0495E MAXIMUM NUMBER OF SESSIONS REACHED FORAPPLICATION nnnnnnnn

Explanation: No more SLU names are available toallocate sessions with this application. Either themaximum sessions value has been reached, or, forshared LUNTs, the pool of names is empty.

System Action: Program continues. An errormessage is sent to the user’s terminal.

Operator Response: Increase the number of sessionspermitted for the application or the pool, if required.

Output: Console.

EMS0496E INVALID STRUCTURED DATA RECEIVED.

Explanation: Invalid structured BIND user datareceived for NetView Access Services as an application.

System Action: The Logon panel is displayed.

Operator Response: Check BIND user data fromsending application (that is, the application that callsNetView Access Services). Check VTAM traces.

Output: Console.

EMS0497E UNSUPPORTED INFO COMMAND ATTEMPTED.

Explanation: The INFO command has been enteredand is not supported.

System Action: The Application Selection panel is dis-played.

Operator Response: A system-internal name of$$INFO$$ needs to be entered for the system ID.

Output: Console.

EMS0498E INVALID UNSTRUCTURED DATA RECEIVED.

Explanation: NetView Access Services receivedinvalid unstructured BIND user data with a logon fromVTAM.

System Action: The Logon panel is displayed.

Operator Response: Check BIND user data.

Output: Console.

EMS0499E REQUEST CANCELED IN EMSESEEX FORACB = aaaaaaaa USER ID = uuuuuuuu.

Explanation: The session establishment exitEMSESEEX gave a return code of 8 for the specifiedACB and user.

aaaaaaaa = ACB nameuuuuuuuu = User ID.

System Action: The server selection is abandonedand the user is shown the Application Selection panelagain, or the Logon panel if the Location ID caused theerror.

Operator Response: Refer to your installation’sversion of session establishment exit EMSESEEX forthe reason.

Output: Console.

EMS0500E ERROR ENCOUNTERED PROCESSING MESSAGE IDxxxx - RC = yy - RC = yy.

Explanation: An error has occurred processing themessage.

xxxx = Message IDyy = Return code.

Return Code Description04 Messages truncation has occurred08 Insert received .. not expected12 Insert expected .. not received16 Message not defined in EMSMSTBL20 Message table was not available24 Error encountered: WTO services28 Error encountered: Trace module32 Error encountered: Trace and WTO36 Invalid length on binary insert40 Trace output length > 400 bytes44 Result of return code 04 and 4048 No return buffer Length/Pointer52 Language not determinable54 BLDL failed56 Invalid language detected, reset to 1.

System Action: Program continues.

Operator Response: If you have changed messagesin the message table, check for the appropriate problem,as described by the return code. Compare yourmessage table with the distributed message table. Ifyou find no error, perform problem determination proce-dure.

Output: Console.

Chapter 1. Operator Messages 21

Page 34: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0501E � EMS0508E

EMS0501E APPLICATION SESSION REJECTED, BIND UNAC-CEPTABLE PLU = pppppp, SLU = llllll.

Explanation: NetView Access Services did not acceptone or more of the parameters in the BIND from theapplication PLU. A possible reason for this errormessage might be that a NetView Access Servicesshared ACB session was passed by the target applica-tion after BIND user data was sent to this session. Thesession must be dropped to avoid session correlationproblems. Check NetView Access Services ACB typedefinition for the target application (PLU). ChangeShared ACB type to Unique or Individual and try again.

System Action: Program continues.

Operator Response: See 3274 Control UnitDescription and Programmer's Guide for permittedparameters. Correct the problem and start the applica-tion again, if required.

Output: Console.

EMS0502E LU = llllllll IS UNDEFINED - LOGON REJECTED.

Explanation: An LU not specified in the NetViewAccess Services input parameters requested a logon.The request has been rejected.

llllllll = Name of logical unit.

System Action: Program continues.

Operator Response: Check if the input parametersregarding this LU name have been specified correctly.Correct the problem and start NetView Access Servicesagain, if required. If the specifications are correct,perform the NetView Access Services problem determi-nation procedures.

Output: Console.

EMS0503E MODULE mmmmmmmm; ERROR CLOSING ACBxxxxxxx - ERROR FIELD = Xee.

Explanation: An error occurred processing a VTAMCLOSE macro.

xxxxxxx = ACB nameee = Return code.

System Action: Program continues, if it is not themain ACB. If it is the main ACB, NetView Access Ser-vices is terminated.

Operator Response: See VTAM error codes to seethe cause of the error.

Output: Console.

EMS0504E ERROR DETECTED IN CS INITIALIZATION - CS TER-MINATING.

Explanation: This message indicates that an unex-pected condition was encountered.

System Action: NetView Access Services terminates.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0505E SESSION ALREADY EXISTS FOR PLU= pppppp,SLU=sssss.

Explanation: You tried to use a specific pseudo ter-minal name (SLU) twice to access the same VTAMapplication (PLU), which has an ACB type of Unique orIndividual.

System Action: Program continues.

Operator Response: Check the NetView Access Ser-vices definition of the target application, correct theproblem, and try again.

Output: Console.

EMS0506E ATTACH FAILED FOR aaaaaaaa ASR - RC = bb.

Explanation: The attach for subtask aaaaaaaa failed.bb specifies the ATTACH request return code.

aaaaaaaa = Load module namebb = Return code.

System Action: NetView Access Services terminates.

Operator Response: See ATTACH error description inSupervisor Services and Macro Instructions. Solve theproblem, if possible. Perform problem determinationprocedure.

Output: Console.

EMS0507E ASR aaaaaaaa ABNORMALLY TERMINATED. RC =bb.

Explanation: An internal error has occurred in thespecified load module name.

aaaaaaaa = EMSELUH or load module namebb = Return code.

System Action: If aaaaaaaa = EMSELUH, NetViewAccess Services continues. If aaaaaaaa = load modulename, NetView Access Services terminates.

Operator Response: If aaaaaaaa = EMSELUH, thesystem is in quiese mode. Shut down NetView AccessServices. If aaaaaaaa = load module name, analyzedump and perform problem determination procedure.

Output: Console.

EMS0508E INVALID MODULE NAME mmmmmmmm IN SAVEWORK AREA

Explanation: An invalid module name has beendetected in the Save Work Area (SWA) during arecovery from an abnormal termination. This unex-pected name in the SWA may be the reason whyNetView Access Services has not successfully recov-ered from an abnormal termination.

System Action: Communication Services tries torecover from the abnormal termination.

Operator Response: Report this problem to IBM asdescribed in Problem Determination in NetView AccessServices Version 2 Operation.

Output: Console and SYSPRINT.

22 NetView Access Services Version 2 Messages

Page 35: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0509E � EMS0518E

EMS0509E LU = llllllll WITH MODE ENTRY NAME mmmmmmmmIS UNDEFINED - LOGON REJECTED.

Explanation: An undefined mode entry name wasencountered during logon processing.

System Action: Continue processing.

Operator Response: Define the encountered modeentry name in the input parameter file, if required.

Output: Console.

EMS0510E SYMPTOM RECORD COULD NOT BE WRITTEN.

Explanation: No resources are available to write asymptom record.

System Action: Program continues.

Operator Response: Check for additional messages.Perform problem determination procedure.

Output: Console.

EMS0511E (variable text)

Explanation: This message is used to issue a NetViewAccess Services symptom record in the case of anabend. See NetView Access Services Version 2 Opera-tion for further information.

System Action: NetView Access Services, or part of it,has abended.

Operator Response: Perform problem determinationprocedure.

Output: Console and SYSPRINT.

EMS0512E INVALID PARAMETER DETECTED IN MODULEmmmmmmmm

Explanation: An invalid parameter has been passed tomodule mmmmmmmm. Module mmmmmmmm hasdetected this parameter while checking the suppliedinput parameter. Depending on the name of themodule, this parameter has been provided by an ASR,VTAM, or NetView Access Services itself.

System Action: Communication Services successfullyavoided an abnormal termination. Program continues.

Operator Response: Report the problem to IBM asdescribed in Problem Determination in NetView AccessServices Version 2 Operation.

Output: Console and SYSPRINT.

EMS0513E ABEND OCCURRED DURING CHECK PROCESSINGIN MODULE mmmmmmmm.

Explanation: This message is issued after anabnormal termination has been successfully recoveredby NetView Access Services. An ASR or VTAM sup-plied an invalid parameter, which caused the abnormaltermination in module mmmmmmmm.

System Action: Communication Services successfullyrevered from an abnormal termination. Program con-tinues.

Operator Response: Report this problem to IBM asdescribed in Problem Determination in NetView AccessServices Version 2 Operation.

Output: Console and SYPRINT. An abnormal termi-nation symptom record, the contents of all registers atthe time of abnormal termination, and the content of thePSW is written to the SYSPRINT file.

EMS0514E LOOP IN BUFFER CHAIN DETECTED; CALLERADDRESS=mmmmmmmm.

Explanation: This message is issued whenever a loopof chained buffers is detected during EMSFBUF proc-essing. EUS or another ASR has issued the EMSFBUFmacro call to free a chain of buffers, but the number ofchained buffers exceeds 65000.

System Action: Program continues.

Operator Response: Report the problem to IBM asdescribed in Problem Determination in NetView AccessServices Version 2 Operation.

Output: Console and SYSPRINT.

EMS0516E MAXIMUM LOGONS REACHED FOR aaaaaaaa - LU =llllllll REJECTED.

Explanation: No session has been established withthis secondary logical unit.

aaaaaaaa = Applicationllllllll = Secondary logical unit name.

System Action: Program continues, session request isrejected.

Operator Response: Check the maximum number ofsessions in the input parameter file, and change thevalue, if required.

Output: Console.

EMS0517E LOGMODE = aaaaaaaa USED BY TERMINALbbbbbbbb IS NOT KNOWN.

Explanation: A terminal logged on to NetView AccessServices and used a Logmode profile that is not known.This message is issued when NetView Access Servicescannot find a match to the supplied logmode entries,even if your private logmodes are added to the NetViewAccess Services mode table. However, NetViewAccess Services passes your private logmode to theserver session to be compatible with the terminal.

System Action: Program continues.

Operator Response: Check if this Logmode isincluded in your private logmode table. If not, add it tothis table. Report the problem with the layout of yourlogmode entry to your local IBM office.

Output: Console.

EMS0518E MODULE mmmmmmmm; ERROR DURING LOGONERROR CODE = Xxx LU = llllllll.

Explanation: No session has been established withthis secondary logical unit. At logon, this messageappears with storage shortage.

mmmmmmmm = Name of SLUxx = Error codellllllll = LU name.

Chapter 1. Operator Messages 23

Page 36: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0519E � EMS0527E

Error Code Description

ð1 OPNDST failed.

ð2 CLSDST failed.

ð8 │ Storage shortage forð9 │ control blocks.ðA │ See SYSPRINT forðB │ other messages. ┘

ðD OPNDST failed.

ðE No CINIT control vector found.

ðF No buffers available, see SYSPRINT for other

messages.

1ð CLSDST failed.

System Action: Program continues.

Operator Response: Check if the service applicationroutine, specified in the input parameters, for the LUwas active at the time of error. Check if the inputparameters regarding this LU name have been specifiedcorrectly.

Correct the problem and start the program again, ifrequired. If the specifications are correct, perform theNetView Access Services problem determination proce-dure.

Output: Console.

EMS0519E LOGMODE mmmmm IS USED FOR RELAY SESSIONWITH TERMINAL nnnn.

Explanation: mmmmm is the logmode name thatNetView Access Services uses for relay sessions.nnnnn is the name of the terminal that is logging on toNetView Access Services. This message occurs, forexample, when a terminal with logmode S3270 logs onto NetView Access Services.

System Action: Program continues.

Operator Response: You can avoid this message ifyou choose a logmode name in your VTAM terminaldefinitions that is known by NetView Access Services.

Output: Console.

EMS0520E APPLICATION xxxxxxxx UNAVAILABLE.

Explanation: NetView Access Services attempted topass a terminal to an application that was not active.

System Action: Program continues. The user gets aninformation message.

Operator Response: Activate application.

Output: Console.

EMS0521I NO CONTROL VECTOR FOR MTS FOUND, RC = xxLU = llllllll.

Explanation: No control vector for Model TerminalSupport was found in the CINIT structure.

System Action: Program continues.

Operator Response: Define MTS data for the applica-tion or suppress the message.

Output: Console.

EMS0522E MODULE mmmmmmmm; ESTAE MACRO FAILURE -RC = rr.

Explanation: Error during processing ESTAE macro.

System Action: NetView Access Services terminates.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0524E MODULE mmmmmmmm; ERROR DURING ALLO-CATION - PLU = pppppp, SLU = l.

Explanation: No session has been established. AVTAM REQSESS operation ended with an error.

mmmmm = Modulepppppp = Primary logical unitlllll = Secondary logical unit.

System Action: Program continues.

Operator Response: Check for additional messages.See VTAM error codes in VTAM: Programming. Correctthe problem and start NetView Access Services again, ifrequired.

Output: Console.

| EMS0525I DIRECT LOGON FAILED FOR TERMINAL oooooooo;| USER = uuuuuuuu, GROUP = gggggggg, MESSAGE =| mmmmmmmm.

| Explanation: An error occurred during the processing| of the direct logon of a terminal. The error message| indicated by mmmmmmmm will not be displayed on the| logon panel because direct logon is in progress.

| oooooooo = LU name of the terminal logging| on to NetView Access Services.| uuuuuuuu = User ID assigned for this logon| process.| gggggggg = Group ID assigned for this logon| process.| mmmmmmmm = ID of the error message that would| have been displayed on the logon| panel if no direct logon was in| progress.

| System Action: The NetView Access Services Logon| Exit is invoked to handle the error situation. Possible| actions that the exit can take are changing the user ID| or group ID, or disconnecting the terminal.

| Operator Response: Read the message text for| message mmmmmmmm to get more details about the| failure. Then modify the NetView Access Services| logon exit EMSELGNX and/or the NetView Access Ser-| vices configuration to correctly handle the direct logon| from terminal oooooooo.

| Output: SYSPRINT.

EMS0527E NO SRVT-ADDRESS FOR SCB-REQUEST.

Explanation: A request for an SCB has been issued,but no service routine vector table (SRVT) address wasprovided.

System Action: Program continues.

Operator Response: Perform problem determinationprocedure.

Output: Console.

24 NetView Access Services Version 2 Messages

Page 37: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0528E � EMS0557E

EMS0528E INVALID yyy CONTROL BLOCK ADDRESS.

Explanation: A FREE request for a control block wasissued, but the address specified does not point to acorresponding control block.

yyy = Control Block Type (ACB, NIB, RPL, SCB, RQE).

System Action: Program continues.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0529E MAXIMUM BUFFER POOL REACHED.

Explanation: A request for a buffer could not be satis-fied because the buffer pool size is already at the limitspecified at initialization.

System Action: Program continues.

Operator Response: Increase the maximum numberof buffers in the initialization parameters, and restartNetView Access Services.

Output: Console.

EMS0532E MODULE mmmmmmmm; ACB nnnnnnnn NOT OPEN.

Explanation: An ACB assumed to be open has beenfound closed. Either the open of the ACB has not beencompleted or the ACB has been closed because of anerror.

mmmmmmmm = Name of the module issuing the message

nnnnnnnn = ACB name.

System Action: Program continues.

Operator Response: Check for other messagesissued for this ACB name. Check the system load if theACB has not been opened. Perform problem determi-nation procedure, if required.

Output: Console.

EMS0550E ERROR DETECTED IN SEND PROCESSING LU =pppppppp - MODULE = mmmmmmmm.

Explanation: A VTAM RECEIVE operation ended withan error.

mmmmmmmm = Name of the module issuing the message

pppppppp = Name of the logical unit.

System Action: Program continues.

Operator Response: Check for additional messagesissued for this LU name. See VTAM error codes inVTAM: Programming. Correct the problem and performproblem determination procedure, if required.

Output: Console.

EMS0551E EMSPRETR FOR RESOURCE ID rrrrrrrr IN MODULEmmmmmmmm FAILED.

Explanation: The “prepare to receive” request to thespecified resource ID could not be performed.

rrrrrrrr = Resource ID

mmmmmmmm = Module name.

System Action: Depending on the module, either theLogon panel is displayed and all applications remainactive, or the corresponding application is deallocated.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0552E MODULE mmmmmmmm; MAXIMUM NUMBER OFRETRIES EXCEEDED FOR LU = nnnnnnnn - CID =Xidididid.

Explanation: This LU has reached its threshold ofSEND errors and will now be closed.

mmmmmmmm = Name of the module issuing the message

nnnnnnnn = Name of the LUidididid = VTAM communication ID.

System Action: Program continues.

Operator Response: Check for other messagesissued for this LU name. See VTAM messages inVTAM: Messages and Codes. Correct the problem.

Output: Console.

EMS0555E INVALID LANGUAGE lll RETURNED BY EMSELVEXFOR TERMINAL ttt.

Explanation: The language identification set by thisinstallation-wide exit EMSELVEX is not valid.

lll = Language number. 1 to 8 are validttt = Terminal identification.

System Action: Program continues.

Operator Response: Check the logic in installation-wide exit EMSELVEX. Correct the problem.

Output: None.

EMS0556E NONE OF THE INSTALLED LANGUAGES ARE SUP-PORTED BY TERMINAL ttt.

Explanation: The terminal does not support the lan-guages installed or the terminal is incorrectly defined inVTAM.

System Action: The terminal is disconnected.

Operator Response: Check the logic in installation-wide exit EMSELVEX. Correct the problem.

Output: None.

EMS0557E TERMINAL bbbbbbbb DEALLOCATED DUE TORETURN CODE xx FROM EMSELVEX

Explanation: The terminal does not support the lan-guages installed or the terminal is incorrectly defined inVTAM.

bbbbbbbb = Terminal identificationxx = Return code from EMSELVEX.

System Action: The terminal is disconnected.

Operator Response: Check the logic in theEMSELVEX installation-wide exit routine and the VTAMinstallation. Correct the problem.

Output: None.

Chapter 1. Operator Messages 25

Page 38: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0562E � EMS0585E

EMS0562E MODULE mmmmmmmm; ERROR DURING RECEIVE -REASON = Xrrr, LU = pppppppp, - CID = Xiiiiiiii.

Explanation: A VTAM RECEIVE operation ended withan error.

mmmmmmmm = Module name (EMSCRCVE)pppppppp = LU nameiiiiiiii = VTAM communication IDrrr = Reason code.

Reason Code DescriptionX'02' Bracket state error detectedX'04' Bracket BID reject detectedX'08' Chaining error detectedX'0C' Exception request received

Receive macro failedX'14' Session in data traffic reset stateX'18' Other reasonX'1A' Send macro failed (sending of response)X'1C' Allocation error (buffer or control block).

System Action: Program continues.

Operator Response: Check for other messagesissued for this LU. See VTAM error codes in VTAM:Programming. Correct the problem.

Output: Console.

EMS0570E CLSDST PASS OF LU nnnnnnnn TO APPLICATIONpppppp FAILED.

Explanation: A VTAM CLSDST operation ended withan error.

nnnnnnnn = Name of LUpppppp = PLU of application.

System Action: Program continues.

Operator Response: Check for additional messagesfor this LU. See VTAM error codes in VTAM: Program-ming. Correct the problem.

Output: Console.

EMS0575E VTAM ACB DEACTIVATED, REASON CODE = rrrr.

Explanation: VTAM has scheduled the NetViewAccess Services TPEND exit routine.

rrrr = VTAM reason code passed to TPEND exit.

System Action: Program continues.

If normal HALT (reason code 0), no new sessions areaccepted. Existing sessions continue processing.NetView Access Services terminates when all sessionsare closed.

If HALT QUICK (reason code 4), all ACBs will be closedand NetView Access Services terminates.

If VARY NET, INACT for an ACB has been issued,NetView Access Services closes the appropriate ACB,and terminates the session. If the main ACB is deacti-vated, NetView Access Services terminates.

If HALT CANCEL (reason code 8), NetView Access Ser-vices tries to close all ACBs immediately and termi-nates.

Operator Response: See VTAM error codes. Correctthe problem, if required.

Output: Console.

EMS0577E UNBIND RECEIVED FOR PLU = pppppppp - SLU =ssssssss - TYPE CODE = Xoo - SENSE = Xnnnnnnnn.

Explanation: An UNBIND session request has beenreceived by the SCIP exit routine.

pppppppp = Name of primary logical unitssssssss = Name of secondary logical unitoo = UNBIND Type Codennnnnnnn = System/User Sense Information.

System Action: Program continues.

Operator Response: See VTAM error codes in VTAM:Programming. Correct the problem.

Output: Console.

EMS0579E SESSION CONTROL REQUEST = Xcc IS INVALID -PLU = pppppppp - SLU = ssssssss - CID = Xidididid.

Explanation: One of the SNA commands RQR,CLEAR, or STSN was received in the SCIP exit.

pppppppp = Name of primary logical unitssssssss = Name of secondary logical unitccccc = Session control request SDT,

CLEAR, or STSNidididid = VTAM Communication ID.

System Action: Program continues.

Operator Response: See VTAM error codes in VTAM:Programming. Correct the problem, if required.

Output: Console.

EMS0581E MODULE mmmmmmmm; INVALID RU TYPE = X ccccccRECEIVED - LU = nnnnnnnn, CID = XIDIDIDID.

Explanation: A VTAM OPNSEC operation ended withan error. The session with the PLU could not be estab-lished.

mmmmmmmm = Name of module issuing the message

nnnnnnnn = Name of logical unitcccccc = RU typeIDIDIDID = VTAM communication ID.

System Action: Program continues.

Operator Response: See VTAM error codes in VTAM:Programming. Correct the problem.

Output: Console.

EMS0585E NS RU RECEIVED - HEADER = Xhhhhhh, REASON =Xrr, SESSION pppppppp-llllllll, SENSE = Xssssssss.

Explanation: An NS RU has been received. Themessage contains information received within therequest unit.

hhhhhh = NS RU Headerrr = Reason codepppppppp = Name of primary logical unitllllllll = Name of secondary logical unitssssssss = Sense Information.

System Action: Program continues.

Operator Response: See VTAM error codes in VTAM:Programming. Correct the problem.

Output: Console.

26 NetView Access Services Version 2 Messages

Page 39: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0588E � EMS0603E

EMS0588E NS PE RU RECEIVED - HEADER = Xhhhhhhhh,REASON = Xrr, SESSION pppppppp-llllllll, SENSE =Xssssssss.

Explanation: An NS PE RU has been received. Themessage contains information received within therequest unit.

hhhhhhhh = NS RU Headerpppppppp = Name of primary logical unitllllllll = Name of secondary logical unitssssssss = System/User Sense informationrr = Reason code.

System Action: Program continues.

Operator Response: See VTAM error codes in VTAM:Programming. If appropriate, correct the problem.

Output: Console.

EMS0595E UNKNOWN OR UNEXPECTED NS RU RECEIVED -HEADER = Xhhhhhh.

Explanation: A network services request unit (NS RU)has been received that is not expected to ever occur onany session established by NetView Access Services.The NetView Access Services NSEXIT routine does notrecognize this NS RU and therefore cannot process it.

hhhhhh = NS RU header.

System Action: Program continues.

Operator Response: Take dynamic dump, performproblem determination procedure.

Output: Console.

EMS0596E EXCEPTION RESPONSE RECEIVED - RTNCD = Xrr,FDBK2 = X ff, SENSE = Xssssssss, LU = llllllll.

Explanation: An exception response has beenreceived.

rr = RPL Return Codeff = RPL Feedback Codessssssss = System/User Sense Informationllllllll = Name of logical unit.

System Action: Program continues.

Operator Response: Check for other messagesreceived from this LU. See VTAM error codes in VTAM:Programming. Correct the problem.

Output: Console.

EMS0597E DATA FLOW CONTROL REQUEST X cc IS INVALID -LU = llllllll.

Explanation: An invalid data flow control request hasbeen received.

cc = Request typellllllll = Name of logical unit.

System Action: Program continues.

Operator Response: Check for other messagesreceived from this LU. See VTAM error codes in VTAM:Programming. Correct the problem.

Output: Console.

EMS0599E ERROR - RPLREQ = Xcc, RTNCD = Xrr, FDBK2 = X ff,SENSE = Xssssssss, LU = llllllllll, CID = Xidididid.

Explanation: An error occurred during processing ofan RPL-based VTAM macro. LERAD/SYNAD exit hasbeen scheduled by VTAM.

cc = RPL request IDrr = Return codeff = Feedback codessssssss = Sense codellllllll = LU Nameidididid = VTAM Communication ID.

System Action: Program continues.

Operator Response: See VTAM error codes in VTAM:Programming. Correct the problem.

Output: Console.

EMS0600E ADDRESSABILITY OF MACRO INTERFACE COULDNOT BE ESTABLISHED - ASR TERMINATES.

Explanation: An error occurred during EMSSTRT.

System Action: Subtask terminates.

Operator Response: Analyze Dump and start the ASRagain.

Output: Console.

EMS0601E ERROR DURING TABLE INITIALIZATION - ASR TER-MINATES.

Explanation: An error occurred during EUS tableinitialization.

System Action: Subtask terminates.

Operator Response: Analyze Dump, correct error, andstart EUS, if possible, otherwise perform problem deter-mination procedure.

Output: Console.

EMS0602E ERROR DURING TIMER INITIALIZATION - ASR TER-MINATES.

Explanation: An error occurred during EUS timerinitialization.

System Action: EUS terminates.

Operator Response: Try to restart EUS. Analyzedump and perform problem determination procedure.

Output: Console.

EMS0603E MODULE nnnnnnnn. GRAPHIC SYMBOL SETS SUP-PORTED BY DEVICE EXCEED NV/AS CAPACITY. LU=oooooooo

Explanation: NetView Access Services administers upto 24 graphic symbol sets that are assigned to graphicsymbol sets of a device. If the device supports morethan 24 graphic symbol sets, this message is issued.

nnnnnnnn = Affected moduleoooooooo = LU name.

System Action: Program continues. The number ofgraphic symbol sets above 24 are ignored.

Operator Response: Perform problem determinationprocedure.

Output: Console.

Chapter 1. Operator Messages 27

Page 40: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0604E � EMS0612E

EMS0604E INVALID RIDT POINTER CHAIN DETECTED FORRESOURCE ID xxxxxxxx.

Explanation: Invalid internal pointers detected.

xxxxxxxx = Resource ID.

System Action: NetView Access Services continues.

Operator Response: Take a dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0605E INVALID RESOURCE ID rrrrrrrr RECEIVED. LU =oooooooo.

Explanation: Resource ID outside range of validresource IDs received.

rrrrrrrr = Resource IDoooooooo = LU name.

System Action: NetView Access Services continues.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0606E 3270 DATA STREAM ERROR DETECTED FORSTRUCTURED FIELD “LOAD PROGRAMMEDSYMBOLS”. SENSE CODE = nnnn. LU = oooooooo.

Explanation: An error was detected in 3270 Informa-tion Display System data stream caused by the Struc-tured field “Load programmed symbols”.

nnnn = Sense code.oooooooo = LU name.

Sense Code Description

X'0001' Structured field length is below minimumlength. Minimum length is given by load pro-grammed symbols basic part.

X'0002' Attempted to load an unloadable characterset.

X'0003' Invalid LCID specified. Valid range is X'40'to X'EF' and value X'FF'.

X'0004' Extended form of SF Load PS was passedbut is not supported by the device.

X'0005' Color triple was specified in SF Load PS butis not supported by the device.

X'0006' Subsection parameter was specified in SFLoad PS but no DBCS are supported by thedevice.

X'0007' Invalid CHAR specified. Valid range isX'41' to X'FE'.

X'0009' RWS specified is not supported by thedevice.

X'0010' ECHAR is required, but was not specified.

X'0011' Passed symbol definitions exceed RWSrange.

X'0012' Passed SF length keeps SF Load PS basicpart only whereby the extension form wasrequested.

X'0013' RWS specified is not supported by the ter-minal.

System Action: Program continues.

Operator Response: Check data stream of applicationprogram.

Output: Console.

EMS0607E INVALID RESOURCE ID STATUS = s DETECTED FORRESOURCE ID yyyy.

Explanation: Resource ID status in RIDT is invalid.

s = Statusyyy = Resource ID.

System Action: Deallocates the session, if possible.

Operator Response: None.

Output: Console.

EMS0608E END USER SERVICE TERMINATES NORMALLY.

Explanation: Termination of EUS was requested.EUS terminates normally.

System Action: EUS terminates.

Operator Response: None.

Output: Console.

EMS0609E NO PLUS ENTRY AVAILABLE - VTAM LOGONREJECTED FOR RESOURCE = rrrrrrr.

Explanation: GETMAIN for PLUS extension failed.

System Action: VTAM logon request is rejected.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0610E ERROR DURING EMSGBUF - ASR TERMINATES.

Explanation: The first EMSGBUF macro during EUSinitialization failed.

System Action: EUS terminates.

Operator Response: Check for additional messagesand perform problem determination procedure.

Output: Console.

EMS0611E ERROR DURING EMSESTR - ASR TERMINATES.

Explanation: The EUS panels could not be estab-lished.

System Action: EUS terminates.

Operator Response: See additional messages issuedby EMSESTR.

Output: Console.

EMS0612E INVALID RC = rr FOR TERMINATE QUIESCERECEIVED.

Explanation: Unknown RC received from EMSRECVfor terminate quiesce function.

System Action: EUS continues.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

28 NetView Access Services Version 2 Messages

Page 41: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0613E � EMS0620E

EMS0613E INVALID WHTRCVD = ww, RC = rr RECEIVED.

Explanation: Unknown combination of WHTRCVD andRC received by EMSRECV.

ww = What received coderr = Return code.

System Action: EUS continues.

Operator Response: Take dynamic dump and performproblem determination procedure.

Output: Console.

EMS0614E ERROR DURING EMSFBUF - ASR TERMINATES.

Explanation: The first EMSFBUF macro during EUSinitialization failed.

System Action: EUS terminates.

Operator Response: Check for additional messagesand perform problem determination procedure.

Output: Console.

EMS0615E RESOURCE ID rrrrrrr NOT FOUND OR GETMAIN FORRIDT EXTENSION FAILED.

Explanation: Received resource ID not found orGETMAIN failed.

rrrrrrrr = Resource ID.

System Action: EUS issues DEALLOC for receivedresource ID and continues.

Operator Response: Check for other messages andperform problem determination procedure.

Output: Console.

EMS0616E EMSGATTR FAILED FOR RESOURCE ID rrrrrr,WHTRCVD = ww, RC = rr. RESOURCE DEALLO-CATED.

Explanation: Macro EMSGATTR failed for receivedresource ID.

rrrrrrrr = Resource IDrr = Return code.

System Action: Deallocates resource. EUS con-tinues.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0617E TERMINAL NOT FOUND FOR RESOURCE = rrrrrrrr,LUNAME = lllllll, WHTRCVD = ww, RC = rr, TERMINAL= ttttttttt.

Explanation: After having received an allocationresponse the corresponding terminal could not be found.

rrrrrrrr = Resource IDllllllll = LU nameww = What received coderr = Return codetttttttt = Terminal ID.

System Action: Deallocates resource.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0618E INVALID WHTRCVD = ww FOR STATUS = f OFRESOURCE = rrrrrrrrr DETECTED.

Explanation: Invalid combination of WHTRCVD andstatus of resource detected.

ww = What received codef = Status coderrrrrrrr = Resource ID.

System Action: Deallocates resource.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0619E VSAM DATA FOR RESOURCE = rrrrrrr, STATUS = sRECEIVED.

Explanation: Unexpected VSAM data for resourcereceived.

rrrrrrrr = Resource IDs = Status code.

System Action: FREEMAIN VSAM records.

Operator Response: Check for further error mes-sages. Invoke the REFRESH facility to synchronizeVSAM profiles with storage tables.

Output: Console.

EMS0620E MODULE nnnnnnnn. THE 3270 DATA STREAM CON-TAINS INVALID DATA AT OFFSET X mm, LU = llllllll,P0 = pppp, P1 =qqqq, SENSE = rr ss.

Explanation: The data stream contains an error.Required value(s) are invalid.

nnnnnnnn = Affected modulemmmm = Position of the order in errorllllllll = Logical unit namepppp = Internal informationqqqq = Internal informationrr = Internal informationss = Sense code.

Sense Code Description01 Invalid order02 Terminal capabilities do not match the require-

ments of th data stream03 Decoded Address space that is outside the pres-

entation space04 The order received is incompatible05 An invalid code point was detected.

Chapter 1. Operator Messages 29

Page 42: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0621E � EMS0628E

If the 3270DS belongs to a Write Structured fieldcommand, the OFFSET is based on the CMND of theOutbound 3270DS structured field. For further informa-tion, refer to 3270 Information Display System DataStream Programmer’s Reference.

System Action: Program continues. The Virtual Ter-minal is set to invalid.

Operator Response: Perform problem determinationprocedure.

Output: Console.

| EMS0621E MODULE nnnnnnnn. INVALID SCREEN SIZE| DETECTED FOR LU = llllllll

| Explanation: A data stream could not be processed| because it exceeded the screen size. The logmodes| used for terminal and application sessions may be| incompatible.

| System Action: Program continues.

| Operator Response: Check that the logmode used for| the logical unit specified in the message is correct.

EMS0623E INVALID COMBINATION OF WHTRCVD = ww AND RC= rr RECEIVED. RESOURCES DEALLOCATED.

Explanation: Invalid combination of WHTRCVD andRC for EMSEPLUR received.

System Action: Deallocates resource.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0624E INVALID COMBINATION OF WHTRCVD = ww AND RC= rr AND STATUS = s RECEIVED. RESOURCESDEALLOCATED.

Explanation: Invalid combination of WHTRCVD, RCand status for resource detected.

ww = What received coderr = Return codes = Status code.

System Action: Deallocates resource.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0625E INVALID INTERNAL POINTERS DETECTED FORRESID = rrrrrrrrr, WHTRCVD = ww, RC = xx ANDSTATUS = s. RESOURCES DEALLOCATED.

Explanation: Invalid pointer detected.

System Action: Deallocates resource.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0626E 3270 DATA STREAM ERROR DETECTED IN MODULE= mmmmmmmm FOR STRUCTURED FIELD QUERYREPLY = xx. SENSE CODE = nnnn. LU = oooooooo.

Explanation: An error was detected in 3270 Informa-tion Display System data stream caused by the struc-tured field QUERY REPLY.

mmmmmmmm = Module namexx = Query reply codennnn = Sense codeoooooooo = LU name.

Sense Code Description

X'0001' Query Reply passed is less than minimumlength defined by architecture.

X'0002' Descriptor missing. At least one descriptorhas to be passed.

X'0003' Invalid descriptor length specified. Lengthspecified was X'00'.

X'0004' Unknown self-defining parameter passed.

System Action: Depends on severity of error.

Operator Response: Check data stream of device.

Output: Console.

EMS0627E MODULE nnnnnnnn. PORTS SUPPORTED BY DEVICEEXCEED NV/AS CAPACITY. LU = oooooooo

Explanation: NetView Access Services administers upto 16 ports that are assigned to a device. If the devicesupports more than 16 ports, this message is issued.

nnnnnnnn = Affected moduleoooooooo = LU name.

System Action: Program continues. The number ofports above 16 are ignored.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0628E INVALID COMBINATION DETECTED: RESID = rrrrrrrr,WHTRCVD = ww, STATUS = s, ERVMOD = v.

Explanation: VSAM data received but not expected.

rrrrrrrr = Resource IDww = What received codes = Status codev = ERVMOD value.

System Action: FREEMAIN VSAM records, deallocateresource.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

30 NetView Access Services Version 2 Messages

Page 43: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0629E � EMS0636E

EMS0629E INVALID WHATRECEIVED INDICATOR RECEIVED:RESID = rrrrrrrrr, WHTRCVD = ww.

Explanation: Invalid WHTRCVD detected.

rrrrrrrr = Resource IDww = What received code.

System Action: Deallocates resource.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0630E STORAGE COULD BE LOST.

Explanation: FREEMAIN got return code 04 while aGETMAIN area chain was being freed.

System Action: Program continues.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0631E 3270 DATA STREAM ERROR DETECTED IN MODULE= mmmmmmmm FOR STRUCTURED FIELD = xx.SENSE CODE = nnnn. LU = oooooooo.

Explanation: An error was detected in 3270 Informa-tion Display System data stream caused by the struc-tured field xx.

mmmmmmmm = Module namennnn = Sense codeoooooooo = LU name.

Sense Code DescriptionX'0001' SF length passed is less than minimum

length defined by architecture.X'0002' Spanning information passed with SF does

not match with previous sent spanning infor-mation.

System Action: Depends on severity of error.

Operator Response: Check data stream of device.

Output: Console.

EMS0632E EMSEFSR FAILED FOR RESID = rrrrrrrr, RESOURCESDEALLOCATED.

Explanation: Terminal screen could not be saved.

rrrrrrrr = Resource ID.

System Action: Deallocate terminal and disconnectapplication.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0633E INVALID QUEUE OF LU NAMES DETECTED, MAX.NO. OF SESSIONS FOR SYSTEM = ssssssss DECRE-MENTED.

Explanation: Invalid queue of LU names detected.

ssssssss = System.

System Action: Maximum number of sessions isdecreased to the number of sessions already reached.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0634E ACCOUNTING EXIT FAILED FOR ACB = aaaaaaaa,UID = uuuuuuuu, FLAG 1 = f, FLAG2 = g.

Explanation: The accounting exit EMSENPME gave anonzero return code for the specified ACB and user.

aaaaaaaa = ACB nameuuuuuuuu = User IDf = Content of Flag 1g = Content of Flag 2

The content of Flag 1 is one of the following:

C ConnectD DisconnectT NetView Access Services termination processing.

The content of Flag 2 is one of the following:

R Relay modeP Pass mode.

System Action: Program continues.

Operator Response: Refer to your installation’sversion of EMSENPME for the reason.

Output: Console.

EMS0635E THE SCREEN SIZE PASSED IN BIND IS NOTDEFINED IN ARCHITECTURE. VALUE = nn,MODULE = mmmmmmmm.

Explanation: A module has received a BIND with ascreen size (byte 24 of BIND) that is not defined inarchitecture.

mmmmmmmm = Module namenn = BIND value.

System Action: Session is canceled.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0636E ART ENTRY nnnnnnnn NOT FOUND IN ART, USERART COULD NOT BE FREED.

Explanation: Used ART not found in chain of activeARTs.

nnnnnnnn = Art entry.

System Action: Program continues.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

Chapter 1. Operator Messages 31

Page 44: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0637E � EMS0649E

EMS0637E INSTALLATION-WIDE EXIT EMSESHRX FAILED WITHRC= xxxx.

Explanation: An error occurred during processing ofthe Shared Session installation-wide exit routineEMSESHRX.

xxx = Return code.

System Action: Program continues.

Operator Response: Check the logic in EMSESHRXinstallation-wide exit routine. Correct the problem.

Output: Console.

EMS0640E TERMINAL NOT FOUND FOR RESOURCE ID xxxx,LUNAME = oooooooo.

Explanation: Corresponding terminal not found afteran allocation response.

xxxx = Resource IDoooooooo = LU name.

System Action: Application deallocated.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0641E INVALID BUFFER RECEIVED FOR RESOURCE IDxxxx, WHTRCVD = nnnn.

Explanation: Invalid buffer received.

xxxx = Resource IDnnnn = What received code.

System Action: Application deallocated.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0642E INVALID LU TYPE RECEIVED FROM LU = oooooooo

Explanation: A CINIT request was received for aVTAM printer with an LU session type other than 1 or 3.The request is rejected.

oooooooo = LU name.

System Action: Deallocates resource.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0643E DYNALLOC FAILURE RC= rr, S99INFO = yyy,S99ERROR = xxx.

Explanation: An MVS/ESA DYNALLOC macro callfailed with a return code and a reason code as indicatedby RC rr, S99INFO = yyy, S99ERROR = xxx.

System Action: Program continues.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0644E OPEN FOR SYSTEM PRINTER FAILED RC= rr.

Explanation: An MVS/ESA OPEN macro call failedwith a return code as indicated by RC=rr.

System Action: Program continues.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0645E PUT FOR SYSTEM PRINTER FAILED.

Explanation: An MVS/ESA PUT macro call failed.

System Action: Program continues.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0646E CLOSE FOR SYSTEM PRINTER FAILED RC= rr.

Explanation: An MVS/ESA CLOSE macro call failedwith a return code as indicated by RC=rr.

System Action: Program continues.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0647E EMSSENDD ERROR xx OCCURRED FOR PRINTERpppppppp IN MODULE mmmmmmmm.

Explanation: The EMSSENDD macro call returned anerror for the printer.

xx = Errorpppppppp = Printer namemmmmmmmm = Module name.

System Action: The printer is deallocated. Programcontinues.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0648E EMSEPBFP ERROR OCCURRED IN MODULEmmmmmmmm.

Explanation: Module EMSEPBFP returned an errorcode.

System Action: The printer is deallocated. Programcontinues.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0649E LOCAL SEND ERROR OCCURRED FOR PRINTERpppppppp IN MODULE mmmmmmmm.

Explanation: A local send error was received for theprinter.

pppppppp = Printer namemmmmmmmm = Module name.

System Action: The printer is deallocated.

Output: Perform problem determination procedure.

32 NetView Access Services Version 2 Messages

Page 45: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0650E � EMS0668E

EMS0650E REQUEST TYPE xx IS A WRONG REQUEST TYPE INMODULE mmmmmmmm.

Explanation: Invalid request type received.

System Action: Module mmmmmmmm returns controlto EMSEADM, which resends the AdministrationSelection panel.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0651E GPRF RECORD xxxxxxxxx UPDATED ON DISK, BUTNOT FOUND IN STORAGE.

Explanation: GPRF record not found in storage.

System Action: EUS continues. The change is madebut is not active until the next startup of NetView AccessServices.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0652E SRTG RECORD xxxxxxxxx UPDATED ON DISK, BUTNOT FOUND IN STORAGE.

Explanation: SRTG record not found in storage.

System Action: EUS continues. The change is madebut not active until the next startup of NetView AccessServices.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0653E SRTS RECORD xxxxxxxxx UPDATED ON DISK, BUTNOT FOUND IN STORAGE.

Explanation: SRTS record not found in storage.

System Action: EUS continues. The change is madebut is not active until the next startup of NetView AccessServices.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0654E PLDT RECORD xxxxxxxxx UPDATED ON DISK, BUTNOT FOUND IN STORAGE.

Explanation: PLDT record not found in storage.

System Action: EUS continues. The change is madebut is not active until the next startup of NetView AccessServices.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0655E RETURN CODE rr RECEIVED FROM EMSEADEX.USER ID uuuuuuuu GROUP gggggggg APPL aaaaaaaaADMIN ID nnnnnnnn.

Explanation: EMSEADEX returned a nonzero returncode.

rr = Hexadecimal error code

uuuuuuuu = User ID to be processed (blank for group related requests)

gggggggg = Group ID to be processedaaaaaaaa = Application ID to be processed

(blank for group related requests)nnnnnnnn = Administrator user ID.

System Action: EUS continues.

Operator Response: Refer to your installation’sversion of EMSEADEX for the reason. This messagemay be suppressed for certain return codes by settingADEXSUPP to Y before returning from EMSEADEX.

Output: Console.

EMS0658E UNEXPECTED LUSTATUS RECEIVED FROMPRINTER pppp IN MODULE mmmmmmmm.CODE=nnnnnnnn.

Explanation: An unexpected LUSTATUS was receivedfrom printer pppp in module mmmmmmmm. Codennnnnnnn describes the error notified by the printer.

System Action: Program continues. The printer isdeallocated.

Output: Perform problem determination procedure.

EMS0665E INVALID POINTER xxxxxxxx TO RIDT ENTRYRECEIVED IN MODULE mmmmmmmm.

Explanation: Invalid internal pointer detected.

System Action: Logical unit deallocated.

Operator Response: Take dynamic dump and performproblem determination procedure.

Output: Console.

EMS0666E INVALID RETURN CODE xx RECEIVED FROMMODULE yyyyyyy IN MODULE mmmmmmmm.

Explanation: Unexpected return code received.

System Action: EUS continues.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0667E x IS AN INVALID RETURN POINT FROM VSAM INMODULE mmmmmmmm, RESID = zzzzzzzzz.

Explanation: Module mmmmm detected an internalerror.

x = Return pointmmmmmmmm = Module namezzzzzzzzz = Resource ID.

System Action: Program continues.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0668E END USER SERVICES INITIALIZED SUCCESSFULLY.

Explanation: Initialization of End User Services wassuccessful.

Operator Response: None.

Output: Console.

Chapter 1. Operator Messages 33

Page 46: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0669E � EMS0678E

EMS0669E INVALID FIELD ID xx FOUND IN USER DATA ARRAYFOR USER uuuuuuuu IN GROUP gggggggg.

Explanation: While decoding the user data arrayreturned from EMSEADEX, an unrecognized field identi-fier was found.

xx = Erroneous field ID in hexadecimaluuuuuuuu = User ID being processedgggggggg = Group ID being processed.

System Action: EUS stops scanning the USERDATAarray at the invalid field. The pseudo-SRTU recordcreated may not contain all of the correct values.

Operator Response: Check that the USERDATA arrayreturned by your version of EMSEADEX matches therequired specifications.

Output: Console.

EMS0670E ASR xxxxxxxx IS NOT KNOWN.

Explanation: This message informs you that allocationto an Application Service Routine was impossible.

System Action: Notify system programmer.

Operator Response: Check whether the desired Appli-cation Service Routine is installed.

Output: Console.

EMS0671E ASR xxxxxxxx IS NOT ACTIVE.

Explanation: This message informs you that allocationto an Application Service Routine was impossible.

System Action: Program continues.

Operator Response: Check whether the named Appli-cation Service Routine should be started.

Output: Console.

EMS0672E ACCOUNTING EXIT FAILED FOR APPLICATIONaaaaaaaa, DATE = yyddd, TIME = hh:mm, FLAG3 = c,FLAG4 = s.

Explanation: A call to accounting exit EMSENPME toaudit an application status for application aaaaaaaafailed. A value of U in FLAG4 indicates the applicationcoming online. A value of D indicates the applicationgoing offline.

System Action: Program continues.

Operator Response: Refer to your installation’sversion of accounting exit EMSENPME for the reason.

Output: Console.

EMS0673E EMSASINQ MACRO CALL FAILED FOR APPLICA-TION aaaaaaaa, RETURN CODE = rr.

Explanation: A status call to macro EMSASINQ forapplication aaaaaaaa failed. rr is the return code.

System Action: Program continues. The statusinquiry is not issued.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0674E VTAM APPSTAT INQUIRE MACRO FAILED FORAPPLICATION aaaaaaaa, RETURN CODE = rr.

Explanation: A status update call to the INQUIREmacro for application aaaaaaaa failed.

System Action: Program continues. The statusupdate is not issued.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0675E VTAM INQUIRE FAILED FOR LU = aaa, RC = rr.

Explanation: The call to the VTAM check macro failed.Return code is rr.

System Action: Program continues.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0676E EMSENQ MACRO CALL FAILED. RC = rr.

Explanation: An attempt made to enqueue INQUIREresults back to CS failed. rr is the return code.

System Action: Program continues. The INQUIREresults are not passed to EUS.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0677E EMSEUS LOAD MODULE NOT IN SYSTEM. INQUIRESCANNOT BE ISSUED.

Explanation: There is no load module called EMSEUSin the system. Therefore, NetView Access Servicesdoes not know where to send the application statusinquiry.

System Action: Program continues.

Operator Response: Check your steplib. LoadEMSEUS if necessary.

Output: Console.

EMS0678E RQE UNAVAILABLE FOR APPLICATION aaaaaaaaSTATUS ssssssss.

Explanation: An attempt to get an RQE to pass theresults of a status inquiry for application aaaaaaaafailed. A status of 0 = application offline; a status of 1 =application online.

System Action: Program continues. The results of theinquiry are not sent to EUS.

34 NetView Access Services Version 2 Messages

Page 47: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0679E � EMS0702E

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0679E INQUIRE RESPONSE NOT RECEIVED FOR APPLICA-TION aaaaaaaa.

Explanation: The result of an application status inquirywas not received by the expiry time of the inquiryinterval.

System Action: Program continues. No new inquiry isissued.

Operator Response: None.

Output: Console.

EMS0680E REXX EXEC nnnnnnnn CANNOT BE STARTED.MODULE mmmmmmmmm, REASON = rrrrrrrr.

Explanation: The specified REXX exec cannot bestarted.

nnnnnnnn = Name of the REXX execmmmmmmmm = Name of the failing modulerrrrrrrr = Reason code.

The following reason codes are defined for moduleEMSERINI.

Reason Code Description

X'04' REXX processing is not possible

X'08' Control block EMSERTCB cannot be retrieved

X'0C' Attach of REXX environment subtaskEMSRENV failed

X'10' Invalid start reason

X'14' Invalid RIDT status.

System Action: The NetView Access Servicesprogram continues.

Operator Response: None.

Output: Console and SYSPRINT.

EMS0681E CALL OF REXX MODULE nnnnnnnn FAILED. RC =cccccccc, REASON = rrrrrrrrr.

Explanation: The call of the necessary REXX modulehas failed.

nnnnnnnn = Name of the REXX modulecccccccc = Return coderrrrrrrr = Reason code.

System Action: The NetView Access Servicesprogram continues.

Operator Response: None.

Output: Console and SYSPRINT.

EMS0682E CALL OF REXX MODULE nnnnnnnn FAILED. RC =cccccccc, ABEND CODE = rrrrrrrrr, ABEND REASON =ssssssss.

Explanation: The call of the necessary REXX modulehas abnormally failed.

nnnnnnnn = REXX module namecccccccc = Return coderrrrrrrr = Abend code

ssssssss = Abend reason.

System Action: The NetView Access Servicesprogram continues.

Operator Response: None.

Output: Console and SYSPRINT.

EMS0683E SYNTAX ERROR DETECTED IN REXX EXECnnnnnnnn. RC = cccccccc.

Explanation: A syntax error was detected in the REXXexec.

nnnnnnnn = REXX exec namecccccccc = Return code.

System Action: The NetView Access Servicesprogram continues.

Operator Response: None.

Output: Console and SYSPRINT.

EMS0684E UNEXPECTED RETURN CODE RC = ccccccccRECEIVED FROM REXX MODULE nnnnnnnn.

Explanation: An unexpected return code was receivedfrom a REXX module.

cccccccc = Return codennnnnnnn = REXX module name.

System Action: The NetView Access Servicesprogram continues.

Operator Response: None.

Output: Console and SYSPRINT.

EMS0685E REXX EXEC nnnnnnnn CANNOT BE STARTED.

Explanation: The specified REXX exec cannot bestarted.

nnnnnnnn = REXX exec name.

System Action: The NetView Access Servicesprogram continues.

Operator Response: None.

Output: Console and SYSPRINT.

EMS0700E EMSESEND ERROR OCCURRED, LU=xxxxxxxx.

Explanation: The send of the panel to the user’sscreen has failed.

System Action: Return to the calling module.

Operator Response: See related messages andperform problem determination procedure.

Output: Console.

EMS0702E MODULE mmmmmmmm DETECTED ERROR IN 3270DATA STREAM. SENSE CODE = nnnn. LU =oooooooo

Explanation: An error in an outbound 3270 trans-mission detected an error in the data stream.

nnnn = Sense codeoooooooo = LU name.

Sense Code Description

X'0001' First byte of data stream is not a valid 3270command.

Chapter 1. Operator Messages 35

Page 48: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0710E � EMS0812I

System Action: Invalid data is sent to the device.NetView Access Services displays the ApplicationSelection panel.

Operator Response: None.

Output: Console.

EMS0710E INVALID PANEL ID xxxxxxxx RECEIVED IN MODULEmmmmmmmm.

Explanation: The received panel ID was not one ofthe panel IDs listed in the NetView Access ServicesVersion 2 Customization.

The function was not performed.

xxxxxxxx = Panel IDmmmmmmmm = Module name.

System Action: Return to the calling module.

Operator Response: Verify that all correct panel IDsare in your panel data set.

Output: Console.

EMS0711E INVALID OR NO WAITCB ENTRY FOUND IN MODULEmmmmmmmm.

Explanation: Invalid internal pointer detected.

mmmmmmmm = Module name.

System Action: Program continues.

Operator Response: Take dynamic dump, andperform problem determination procedure.

Output: Console.

EMS0720E INTERNAL ERROR OCCURRED IN MODULEmmmmmm

Explanation: An event has occurred for which noaction is provided in the broadcast automation table.

System Action: The requesting user is disconnected.

Operator Response: None.

Output: Console.

EMS0721E EVENT = ee BROSC = sc ACODE = ac STATE = stWPANID = pid WRCVD = pidCMD = cmd WPCMD =wpcmd.

Explanation: An invalid event has been detected inthe selective broadcast function. This message is dis-played following message EMS0720 to enable you tolocate the error.

System Action: The user is disconnected.

Operator Response: Locate the error.

Output: Console.

EMS0800E EMSECPFR: WRONG CONVERSATION STATUS.FUNCTION CANCELED.

Explanation: The module was called with invalidparameters in the control block. There is a panelmessage associated with this console message.

System Action: Function terminated and NetViewAccess Services displays the Application Selectionpanel.

Operator Response: Perform the problem determi-nation procedure.

Output: Console.

EMS0802E EMSECOPY: INPUT PARAMETER ERROR. FUNC-TION CANCELED.

Explanation: The module was called with invalidparameters in the control block. There is a panelmessage associated with this console message.

System Action: The function terminated and the Appli-cation Selection panel is displayed.

Operator Response: See associated messageEMS1314E. Perform the problem determination proce-dure.

Output: Console.

EMS0810I BROADCAST MESSAGE mmmm/ll ADDED byuuuuuuuu ON yy–mm–dd AT hh.:mm.

Explanation: The broadcast message was added tothe system.

mmmm = Message IDll = Language IDuuuuuuuu = Administrator user ID, or consoleyy–mm–dd = ISO datehh:mm = ISO time.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0811I BROADCAST MESSAGE mmmm/ll DELETED BYuuuuuuuu ON yy–mm–dd AT hh:mm.

Explanation: The broadcast message was deletedfrom the system.

mmmm = Message IDll = Language IDuuuuuuuu = Administrator user ID, or consoleyy–mm–dd = ISO datehh:mm = ISO time.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0812I BROADCAST MESSAGE mmmm/ll UPDATED BYuuuuuuuu ON yy–mm–dd AT hh:mm.

Explanation: The broadcast message was updated inthe system.

mmmm = Message IDll = Language IDuuuuuuuu = Administrator user ID, or consoleyy–mm–dd = ISO datehh:mm = ISO time.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

36 NetView Access Services Version 2 Messages

Page 49: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0813I � EMS0853E

EMS0813I BROADCAST MESSAGE mmmm/ll PURGED BYTIMER EVENT ON yy–mm–dd AT hh:mm.

Explanation: The broadcast message was purgedfrom the system by a timer event.

mmmm = Message IDll = Language IDuuuuuuu = Administrator user ID, or consoleyy–mm–dd = ISO datehh:mm = ISO time.

System Action: Program continues.

Operator Response: None.

Output: SYSPRINT

EMS0814E INTERNAL ERROR OCCURRED IN MODULEmmmmmmmm. FUNCTION=ff.

Explanation: An internal error was detected in modulemmmmmmmm. The specified function ff is invalid.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0815I PURGE FOR BROADCAST MESSAGE mmmmmm/11BY VSAM FAILED. RC= xx.

Explanation: A purge on the VSAM data set for themessage mmmmmm/11 failed. Return code is xx.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0816E INTERNAL ERROR OCCURRED IN MODULEmmmmmmmm FOR A MESSAGE EVENT e.

Explanation: An internal error occurred in modulemmmmmmmm by handling a message with an event e.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0836E AUTOMATIC LOGON/LOGOFF STOPPED - USERxxxx, APPLICATION yyyy.

Explanation: During automatic logon or logoff invoca-tion an error code from EMSEDMF was returned. Acorresponding error message of this module shouldprecede this message.

System Action: The logon or logoff generation is ter-minated and a message is sent to the user’s screen.

Operator Response: None.

Output: Console.

EMS0837E ERROR RESPONSE FROM APPLICATION yyyyyyyy.FUNCTION CANCELED.

Explanation: During a logon or logoff generation thefunction received an error response from EMSSENDDwhen attempting to send data to the application. Thereis a panel message associated with this consolemessage.

System Action: Logon/logoff generation terminated.The Application Selection panel is displayed.

Operator Response: Determine problem with applica-tion, take corrective action, and reenable user, probablyby deallocating the session with the application andasking the user to reselect the application from theApplication Selection panel.

Output: Console.

EMS0839E ERROR IN LOGOFF GENERATION - APPLICATIONyyyyyyyy SESSION STOPPED.

Explanation: This message is displayed if applicationyyyyyyyy fails the logoff generation process. The appli-cation is deallocated.

System Action: Logon/logoff generation is terminatedand the application is deallocated.

Operator Response: Inform your system adminis-trator. The system or group administrator should checkthe recorded logoff sequence for his group or the user,and rerecord, if necessary.

Output: Console.

EMS0852E BR CANCELED. UNEXPECTED MESSAGE FROMAPPLICATION yyyy FOR USER xxxx.

Explanation: The recording function was interruptedby an unexpected message stream. A message wasreceived from the application when a user response wasexpected. The function is terminated at the pointreached so far. There is a panel message associatedwith this console message.

System Action: Logon/logoff recording terminated.NetView Access Services displays the ApplicationSelection panel.

Operator Response: See associated messageEMS1344I. Use of broadcast messages can interruptthe logon/logoff generation and recording functions.

Output: Console.

EMS0853E RECORDING FUNCTION CANCELED DUE TO ANINTERNAL ERROR OR UNEXPECTED EVENT; USERxxxxxxxx.

Explanation: The module was called with invalidparameters in the control block or because of an unex-pected power-off event at the terminal. In both casesthe recording function is terminated and any recordingfreed. The first case is an internal error and should bereported to the system administrator. In the case of ter-minal power-off, the user can start a new recordingwhen the terminal is switched on again.

There is a panel message associated with this consolemessage.

Chapter 1. Operator Messages 37

Page 50: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0854E � EMS0883E

System Action: Logon or logoff recording terminated.NetView Access Services displays the ApplicationSelection panel.

Operator Response: Inform the system administratoror have the user switch on the terminal.

Output: Console.

EMS0854E BR FUNCTION ENDED BY EMSEAPAN. SERVER =aaaaaaaa, USER = uuuuuuuu, RC = xx.

Explanation: The user-exit routine EMSEAPAN calledto analyze a data stream and return a panel ID returnedwith error code xx. There is a panel message associ-ated with this console message.

aaaaaaaa = Serveruuuuuuuu = Userxx = Reason code.

System Action: Logon or logoff recording terminates.NetView Access Services displays the ApplicationSelection panel.

Operator Response: Refer to your installation’sversion of EMSEAPAN for the reason code.

Output: Console.

EMS0861E ERROR OCCURRED READING/WRITING ALLTENTRIES FOR USER xxxxxxxx.

Explanation: The ALLT entries for the user could notbe read or written. A panel message EMS1374I isassociated with this console message.

System Action: Function terminated. NetView AccessServices displays the Application Selection panel.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0870E EMSEREFR ERROR IN MACRO CALL (EMSINREF);RC=nn.

Explanation: After completion of a refresh, whethersuccessful or not, the EMSINREF macro call was issuedto notify another ASR. This macro call has failed.

nn = Return code of the failing macro.

System Action: Program continues.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0879E THE REFRESH FACILITY HAS FAILED IN MODULEmmmmmmmm RC = rr.

Explanation: An error was detected during refresh.

System Action: The refresh function is terminated.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0880I THE PROFILE DATABASE IS IN USE; TRY AGAINLATER.

Explanation: Another NetView Access Servicessystem has locked the VSAM database for profile main-tenance, so attempts by any other NetView Access Ser-vices system to ADD, UPDATE, or DELETE records arenot possible.

System Action: Program continues.

Operator Response: Try again later.

Output: Console.

EMS0881E EMSEDMF INTERNAL ERROR. INVALID I/O TYPE =Xnn.

Explanation: The data management facility (DMF)control block passed via register 1 contained an invalidI/O type.

nn = Error code.

System Action: The program terminates with a returncode of 10.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0882E EMSEDMF INTERNAL ERROR. INVALID TABLENAME = Xnnnnnnnn.

Explanation: The DMF control block passed via reg-ister 1 contained an invalid table name.

System Action: The program terminates with a returncode of 10.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0883E EMSEDMF ERROR DURING xxxxxxxx RC = Xnn.

Explanation: An error occurred during OPEN/CLOSEof the VSAM data sets, or during the ATTACH orDETACH of the VSAM subtask.

xxxxxxxx = Open or closenn = Return code.

System Action: The program terminates with a returncode of 08.

Operator Response: For OPEN/CLOSE see theaccompanying VSAM messages (EMS0890-0892), orthe specific VSAM system messages, and act accord-ingly. For ATTACH check that the load library is cor-rectly set up, and that a large enough region size wasspecified on the job startup size parameter. ForDETACH there may be other messages to explain thereason for failure. If this is not successful, performproblem determination procedure.

Output: Console.

38 NetView Access Services Version 2 Messages

Page 51: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0884E � EMS0892E

EMS0884E EMSEDMF: DOWNWARD DELETES FAILED FORTABLE xxxxxxxx, CHECK DATA SET INTEGRITY ANDRETRY.

Explanation: The profile data sets are hierarchicallyorganized, such that, for example, when a group isdeleted, all the corresponding groups and user recordsare also deleted. This is performed from the lowestupwards, that is, the user logon profiles are first deleted,and then up the chain until the group itself is deleted.This ensures that if any error occurs during this process,the hierarchy is still intact, though some of the lowestlevel deletes may have already been performed. Themost usual cause of an error would be insufficientstorage to satisfy the request.

System Action: The program terminates with a returncode of 08, causing a message to be displayed on theterminal.

Operator Response: Check via IDCAMS.

EMS0885E qqqqqqq FAILURE ON VSAM DATA SET; RC= xx.

Explanation: qqqqqqq (ENQUEUE or DEQUEUE) onVSAM data set has failed. The return code is xx.

System Action: Program continues.

Operator Response: Inform IBM.

Output: Console.

EMS0886I THE REFRESH FACILITY HAS STARTED.

Explanation: The VSAM data sets (SRTS, SRTG,GRPF, BROD, and PLDT) will be loaded into theNetView Access Services profiles, so that the latestupdates to the VSAM files can be used by the runningNetView Access Services.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0887E TRACE variable text

Explanation: Information message containing tracedata.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0889I THE REFRESH FACILITY HAS COMPLETED SUC-CESSFULLY.

Explanation: The VSAM data set (SRTS, SRTG,GRPF, BROD, and PLDT) has been loaded successfullyinto the NetView Access Services profiles.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0890E VSAM xxxx ERROR ON FILE yyyy, R15 = Xnn, R00 =Xmm.

Explanation: An error return was received during theoperation specified. The various return codes are givenas well as file name. xxxx indicates macro-type; pos-sible values are: GENCB/SHOWCB/MODCB.

yyyy = Filename.

System Action: Error code return to calling module(EMSEVQH), which reports the error to the modulerequiring the data access via the RQE return code field.

Operator Response: Perform the problem determi-nation procedure, and refer to the VSAM manuals.

Output: Console.

EMS0891E VSAM xxxx ERROR ON FILE yyyy, R15 = Xnn, ERROR= Xmm.

Explanation: xxxx indicates macrotype; possiblevalues are: OPEN/CLOSE. An error return wasreceived during the operation specified. The variousreturn codes and error codes are given as well asfilename.

System Action: Error code return to calling module(EMSEVQH), which reports the error to the modulerequiring the data access via the RQE return code field.

Operator Response: Perform problem determinationprocedure.

Problem Determination: Reference should be madeto the problem determination guide for VSAM, using var-iable information in the message (return codes andfilename). It may be possible to rectify the error byincreasing the region size, and run an IDCAMS jobusing the VERIFY function. If this is not successful,perform problem determination procedure.

Output: Console.

EMS0892E VSAM xxxx ERROR ON FILE yyyy, FDBK = Xnn,KEYLEN = Xmm.

Explanation: xxxx indicates macrotype; possiblevalues are: GET/PUT/ERASE/UPDATE/POINT. Anerror return was received during the operation specified.The various return codes and feedback area are givenplus filename. UPDATE is not a VSAM function, butconsists of the VSAM functions ERASE followed byPUT.

System Action: Error code return to calling module(EMSEVQH), which reports the error to the modulerequiring the data access via the RQE return code field.

Operator Response: Perform problem determinationprocedure.

Problem Determination: Reference should be madeto the problem determination guide for VSAM, using var-iable information in the message, that is, return codesand filename. It may be possible to rectify the error byincreasing the region size, or merely by retrying thefunction that caused the error, or by using the adminis-trator function to find and correct the error. Feedbackcode X'74' means the initial data set load may havebeen faulty. The second and third steps of the load jobcause a dummy record to be added with a key ofhexadecimal FFs. This is essential for execution. It can

Chapter 1. Operator Messages 39

Page 52: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0893E � EMS0902E

be checked via the IDCAMS PRINT function. If this isnot successful, perform problem determination proce-dure.

Output: Console.

EMS0893E VSAM PHYSICAL ERROR ON FILE yyyy, FDBK =Xnn.

Explanation: A physical error occurred during a VSAMoperation, register 15 was X'0C' on return. The feed-back code and filename are given.

System Action: Error code return to calling module(EMSEVQH), which reports the error to the modulerequiring the data access via the RQE return code field.

Operator Response: Perform problem determinationprocedure.

Problem Determination: Reference should be madeto the problem determination guide for VSAM, using var-iable information in the message, feedback code, andfilename. If this is not successful, perform problemdetermination procedure.

Output: Console.

EMS0894E VSAM EOF ENCOUNTERED ON FILE yyyy.

Explanation: The EODAD routine in the VSAMhandler was entered during an operation. This is notnecessarily a severe error, as in most situationsNetView Access Services can continue running success-fully.

System Action: Normal continuation.

Operator Response: Perform problem determinationprocedure.

Problem Determination: The initial data set load hasnot run successfully. The second and third steps of theload job cause a dummy record to be added with a keyof hexadecimal FFs. This is essential for correct exe-cution. Alternatively, at some time since data set cre-ation, the dummy record has been deleted; either anIMPORT/EXPORT job failed, or a REPRO was runusing a non-VSAM data set that did not contain a repre-sentation of the dummy record. This can be checkedvia the IDCAMS PRINT function. A dummy record canbe added using the IDCAMS REPRO function. TheVSAM data sets must not be used at the same time forrunning the product. If this is not successful, performproblem determination procedure.

Output: Console.

EMS0895I END USER SERVICES WILL PROCEED WITHOUT ANSRTU DATA SET.

Explanation: You have omitted the DD statement forthe SRTU (user profile) VSAM data set.

System Action: This is acceptable. EUS will supportonly Public and External groups. Attempts at readingthe SRTU for users in normal groups will result in a “Notfound” or “End of File” condition. Attempts at writing tothe data set are ignored.

Operator Response: If you wish to use N groups thensupply a DD statement for the SRTU data set(EMSSRTU).

Output: Console.

EMS0896E INTERNAL ERROR IN MODULE mmmmmmmm.

Explanation: The VSAM control block passed via reg-ister 4 contained invalid information.

System Action: The program terminates with a returncode of 10.

Operator Response: Perform problem determinationprocedure.

Output: Console.

EMS0897E INTERNAL ERROR DETECTED IN MODULEmmmmmmmm. REASON CODE = cc.

Explanation: An internal error occurred in modulemmmmmmmm

Return Code DescriptionX'10' Invalid VSMTYPE detectedX'12' Invalid UARRACN detectedX'14' Invalid ADEXCMD detectedX'18' Invalid VSMCBNM detected.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0898E DYNALLOC FAILED FOR DD NAME dddddddd, RC=rr,S99INFO=yyy, S99ERROR=xx.

Explanation: An MVS/ESA DYNALLOC macro callfailed for DD name dddddddd. This can happen if youomit SRTU DD name in your JCL.

System Action: Program continues. The DD name isused as ENQ resource name.

Operator Response: Check SVC 99 return and sensecodes.

Output: Console.

EMS0900E INTERNAL ERROR IN dddddddd. P1=ww,P2=xx,P3=yyyy, P4=zzzz.

Explanation: An internal error occurred in moduledddddddd. P1, P2, P3, and P4 provide module-internalinformation necessary to analyze the problem.

System Action: Program terminates.

Operator Response: Console.

EMS0902E SCANNING TERMINATED.

Explanation: The error is so severe that the controlstatement processor must terminate any furtherchecking of the control statements.

System Action: Control statement scanning is termi-nated. The program terminates with return code 08 indi-cating control card checking has failed.

Operator Response: Correct the indicated error andstart NetView Access Services again.

Output: SYSPRINT

40 NetView Access Services Version 2 Messages

Page 53: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0903E � EMS0908E

EMS0903E INTERNAL ERROR rrrrrrrr IN MODULE mmmmmmmm.

Explanation: This message indicates that the moduleencountered some internal error.

rrrrrrrr = Error codemmmmmmmm = Module name.

Error Code Description (Module EMSRENV)

X'0001' Module IRXINIT cannot be loaded

X'0002' No RQE available

X'0003' ASR EMSEUS is not active

X'0004' GETMAIN for EMSRRBF failed

X'0005' FREEMAIN for EMSRRBF failed.

Error Code Description (Module EMSRAPI)

X'01' Error in STIMERM macro

X'02' No RQE available

X'03' ASR EMSEUS is not active

X'04' STIMER cancel error.

Error Code Description (Module EMSTABL)

X'01' Table allocation failed.

Error Code Description (Module EMSERCON)

X'01' Unknown return code from VT.

Error Code Description (Module EMSERCOP)

X'01' Unknown return code from VT.

Error Code Description (Module EMSERDSP)

X'01' Get RQE failed.

X'02' Unknown return code from VT.

Error Code Description (Module EMSEREXX)

X'01' Invalid function request

X'02' Invalid input parameterREXX_CONTROL_BLOCK@ = HEX00

X'03' Invalid input parameterREXX_BUFFER = HEX00

X'04' Get RQE failed

X'05' PAUSE SEND processing failed

X'06' PAUSE UPDATE processing failed

X'07' POST after reenqueue failed

X'08' POST after function processed failed

X'09' Invalid vt_id detected.

Error Code Description (Module EMSERQRY)

X'01' Unknown return code from VT.

Error Code Description (Module EMSERSEA)

X'01' Unknown return code from VT.

Error Code Description (Module EMSERSKY)

X'01' Unknown return code from VT.

Error Code Description (Module EMSERXQS)

X'01' No more storage available to put results in.

System Action: If the module name is EMSIPARS, theprogram terminates. Otherwise, processing continues.

Operator Response: Perform problem determinationprocedure, if required.

Output: Console and SYSPRINT.

EMS0904E UNRECOGNIZED CONTROL STATEMENT TYPEyyyyyyyy.

Explanation: An input control statement other thanAPPL or SERVRTN was encountered.

yyyyyyyy = Encountered statement type.

System Action: Control statement scanning is termi-nated. NetView Access Services terminates.

Operator Response: Specify valid input control state-ment and restart NetView Access Services.

Output: SYSPRINT

EMS0905E UNRECOGNIZED KEYWORD yyyyyyyy.

Explanation: Keyword yyyyyyyy is not defined for theassociated statement type.

System Action: Scanning continues to determine anyadditional errors. NetView Access Services terminates.

Operator Response: Correct the keyword parameterspecification and restart NetView Access Services.

Output: SYSPRINT

EMS0906E A CONTROL STATEMENT PARAMETER CANNOTSPAN MORE THAN ONE LINE.

Explanation: A control statement can be more thanone line. However, keywords and their associatedparameter values must be specified completely on oneline.

System Action: Control statement scanning is termi-nated. NetView Access Services terminates.

Operator Response: Correct the control statement sothat the keyword or parameter value is fully specified ona single line and restart NetView Access Services.

Output: SYSPRINT

EMS0907E INVALID DELIMITER ENCOUNTERED.

Explanation: An invalid delimiter was found duringcontrol statement scanning. The line that contains theinvalid delimiter is printed again followed by a line con-taining only a vertical bar (|) that indicates the location ofthe delimiter. The vertical bar is positioned directlybeneath the error or the invalid delimiter. The indicateddelimiter is not allowed in the control statement syntax.

System Action: Control statement scanning is termi-nated. NetView Access Services terminates.

Operator Response: Correct control statement syntaxand restart NetView Access Services.

Output: SYSPRINT

EMS0908E LAST CONTROL STATEMENT INCOMPLETE.

Explanation: The parameters of this statement werespecified using more than one line and the end-of-filewas encountered before the end-of-statement wasdetected. Either a comma was specified after the lastrecognized keyword parameter value or a parameterspecification was incomplete when the end-of-file wasencountered.

System Action: NetView Access Services terminates.

Chapter 1. Operator Messages 41

Page 54: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0909E � EMS0918E

Operator Response: Correct control statement syntaxand restart NetView Access Services. Check if youhave accidentally ended the last parameter with acomma instead of a blank.

Output: SYSPRINT

EMS0909E PARAMETER VALUE TOO LONG.

Explanation: More characters or digits than the validlimit were specified.

System Action: Scanning continues to determine anyadditional errors. NetView Access Services terminates.

Operator Response: Check the valid limit in thecontrol statement. Correct the parameter value tocontain up to the valid number of characters and restartNetView Access Services.

Output: SYSPRINT

EMS0910E PARAMETER VALUE TOO SHORT.

Explanation: Fewer characters or digits than the validminimum limit were specified.

System Action: Scanning continues to determine anyadditional errors. NetView Access Services terminates.

Operator Response: Check the valid minimum limit inthe control statement. Correct the parameter value tocontain at least the minimum number of characters andrestart NetView Access Services.

Output: SYSPRINT

EMS0911E PARAMETER VALUE ERROR, ILLEGAL SYMBOLICNAME.

Explanation: The indicated parameter must have avalid name as its value. A valid name must contain onlythe characters: uppercase letters (A-Z), numeric digits(0-9), at sign (@), dollar sign ($), or the number sign (#).Generic names can contain an asterisk (*). Further-more, a name may not begin with a numeric digit. Theindicated name parameter value violated one of theabove rules.

System Action: Scanning continues to determine anyadditional errors. NetView Access Services terminates.

Operator Response: Correct the name parametervalue to be a valid name and restart NetView AccessServices.

Output: SYSPRINT

EMS0912E PARAMETER VALUE ERROR, ILLEGAL NUMBER.

Explanation: This parameter must have a numericvalue. The parameter value must be a sequence ofnumeric digits (0-9). The indicated numeric parametervalue contains an invalid character.

System Action: Scanning continues to determine anyadditional errors. NetView Access Services terminates.

Operator Response: Correct the numeric parametervalue to be a valid number and restart NetView AccessServices.

Output: SYSPRINT

EMS0913E PARAMETER yyyyyyyy SPECIFIED MORE THANONCE IN THE SAME STATEMENT.

Explanation: Parameter yyyyyyyy was repeated in thesame control statement.

System Action: Scanning continues to determine anyadditional errors. NetView Access Services terminates.

Operator Response: Correct the control statements sothat the indicated parameter is specified only once andrestart NetView Access Services.

Output: SYSPRINT

EMS0914E UNEXPECTED BLANK WITHIN A PARAMETER.

Explanation: Blank characters may not occur in thespecification of a keyword parameter. For example,SOMEKEYWORD = 4 should be written asSOMEKEYWORD=4. A blank character was encount-ered during the processing of a keyword parameter.

System Action: Scanning of all control statements isterminated. NetView Access Services terminates.

Operator Response: Remove the erroneous blankcharacters from the control statement and restartNetView Access Services.

Output: SYSPRINT

EMS0915E MORE THAN TWO VALUES SPECIFIED FOR INPLUPARAMETER.

Explanation: The list of the keyword, INPLU, containsmore than two items.

System Action: Scanning of all control statements isterminated. NetView Access Services terminates.

Operator Response: Remove the erroneous itemsfrom the list and restart NetView Access Services.

Output: SYSPRINT

EMS0917E PARAMETER INPUT FILE CAN NOT BE OPENED.

Explanation: The parameter input file cannot beopened.

System Action: Scanning terminates.

Operator Response: Examine the reason for the openfailure.

Output: SYSPRINT

EMS0918E THE ASTERISK MUST BE THE LAST CHARACTER.

Explanation: A generic name, that is, a name that isallowed to contain an asterisk, is found. Only oneasterisk is allowed, and it must be the last character.

System Action: Scanning continues to determine anyadditional errors.

Operator Response: Correct the generic name.

Output: SYSPRINT

42 NetView Access Services Version 2 Messages

Page 55: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0919E � EMS0928E

EMS0919E VALUES IN BRACKETS IGNORED. ALREADY SPECI-FIED IN LINE nnnnnnnn.

Explanation: The INPLU parameter value pair hasbeen specified before for the same SERVRTN state-ment in line number nnnnnnnn.

System Action: Scanning continues. If no additionalerror is detected, NetView Access Services is started. Ifno other error occurs during NetView Access Servicesprocessing, the return code will be 4 after NetViewAccess Services has terminated.

Operator Response: Remove the unnecessary INPLUspecification before restarting NetView Access Services.

Output: SYSPRINT

EMS0920E VALUE PAIR IN BRACKETS IS NOT UNIQUE: SEELINE xxx.

Explanation: The INPLU parameter value pair hasbeen specified before in line number xxx, but for a dif-ferent SERVRTN statement.

System Action: NetView Access Services terminates.

Operator Response: Ensure that every INPLU param-eter value pair is unique.

Output: SYSPRINT

EMS0921E PARAMETER INPUT FILE IS EMPTY.

Explanation: The program has found an empty param-eter input file.

System Action: Control statement scanning is termi-nated. NetView Access Services terminates.

Operator Response: Prepare an input parameter filethat contains at least the required keyword values.

Output: SYSPRINT

EMS0922E SUBPARAMETER LU NAME MUST BE SPECIFIED.PARAMETER INPLU IGNORED.

Explanation: The first value (LUNAME) of the INPLUparameter value pair was not specified.

System Action: Scanning continues to determine anyadditional errors. NetView Access Services terminates.

Operator Response: Insert an LUNAME in the indi-cated INPLU parameter value pair. You might haveseparated two parameters by a blank and comma.

Output: SYSPRINT

EMS0923E THE IDLE TIME PARAMETER VALUE MUST BEHHMM.

Explanation: An invalid IDLETIME value was found.

HH must be in the range 00-23, and MM in the range00-59.

System Action: Scanning continues to determine anyadditional errors. NetView Access Services terminates.

Operator Response: Correct the specified idle timevalue.

Output: SYSPRINT

EMS0925E REQUIRED PARAMETER xxxxxxx IS MISSING IN PRE-VIOUS STATEMENT.

Explanation: Parameter xxxxxxx of a statement is notspecified in the input parameter file.

System Action: Scanning continues to determine anyadditional errors. NetView Access Services terminates.

Operator Response: Insert the missing parameters inthe input parameter statement.

Output: SYSPRINT

EMS0926E MAXIMUM BUFFER SPACE EXCEEDS 2 GBYTE.

Explanation: The product of the BUFFMAXN valueand BUFFLEN exceeds 2 gigabytes.

System Action: Sets the buffer size to indefinite. Thismeans that wherever the allocated buffer size isexhausted, NetView Access Services tries to extend thebuffer size.

Scanning continues. If no additional error is detected,NetView Access Services starts. If no other erroroccurs during NetView Access Services processing, thereturn code will be 4 after NetView Access Services hasterminated.

Operator Response: Do not specify a BUFFMAXNvalue if no buffer limit is desired. If the buffer should notexceed a special limit, reduce the BUFFMAXN value orBUFFLEN value.

Output: SYSPRINT

EMS0927E BUFFER ELEMENT LENGTH IS CHANGED TO xxxxxBYTES.

Explanation: If a BUFFLEN value is specified, which isnot a multiple of 256, the buffer element size isincreased to the next value that is a multiple of 256.For example, a specified BUFFLEN of 1200 will beincreased to 1280. If the BUFFLEN value is smallerthan 1024, it is increased to 1024. If the BUFFLENvalue is greater than 4096, it is reduced to 4096.

xxxxx = New buffer element size.

System Action: Scanning continues. If no additionalerror is detected, NetView Access Services starts. If noother error occurs during NetView Access Servicesprocessing, the return code will be 4 after NetViewAccess Services has terminated.

Operator Response: To avoid the informationmessage, update the BUFFLEN value.

Output: SYSPRINT

EMS0928E ILLEGAL VALUE SPECIFIED FOR yyyyy PARAM-ETER.

Explanation: A value, which is not in a defined range,is detected. For example: If you specifyROUTCODE=18, you receive this message.

yyyyy = Found parameter.

System Action: Scanning continues to determine anyadditional errors. NetView Access Services terminates.

Operator Response: Correct the indicated value.

Output: SYSPRINT

Chapter 1. Operator Messages 43

Page 56: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0929E � EMS0941E

EMS0929E NAME VALUE xxxxx IS NOT UNIQUE. SEE LINE yyyy.

Explanation: The same NAME value is specified in dif-ferent SERVRTN statements.

xxxxx = Found NAME valueyyyy = Found line number.

System Action: Control statement scanning is termi-nated. NetView Access Services terminates.

Operator Response: Use different NAME values fordifferent SERVRTN statements.

Output: SYSPRINT

EMS0930E NUMBER OF INPLU PARAMETERS EXCEEDS THELIMIT OF xxxxxx.

Explanation: The INPLU parameter cannot be speci-fied more than 999999 times.

xxxxxx = 999999.

System Action: NetView Access Services terminates.

Operator Response: Use generic names and startNetView Access Services again.

Output: SYSPRINT

EMS0931E STATEMENT ssss HAS BEEN SPECIFIED BEFORE.SEE LINE mmmmmmmm

Explanation: A statement was specified more thanonce.

ssss = Statementmmmmmmmm = Line number.

System Action: Control statement scanning is termi-nated. NetView Access Services terminates.

Operator Response: Specify all APPL parameters inthe same statement.

Output: SYSPRINT

EMS0932E SERVICE ROUTINE DEFINITION EXCEEDS THE LIMITOF 9.

Explanation: The SERVRTN statement was specifiedmore than nine times.

System Action: Control statement scanning is termi-nated. NetView Access Services terminates.

Operator Response: Reduce the number ofSERVRTN statements.

Output: SYSPRINT

EMS0933E STATEMENT nnnnnnnn WAS NOT SPECIFIED.

Explanation: Either no APPL statement or noSERVRTN statement was specified.

nnnnnnnn = Encountered name.

System Action: NetView Access Services terminates.

Operator Response: Insert the missing statement.

Output: SYSPRINT

EMS0935E THE TEXT IN THE NEXT LINE IS INTERPRETED AS ACOMMENT.

Explanation: This message occurs either when aremark begins with a comma or the next word specifiedafter a blank is a keyword. For example:

APPL ACBNAME=A ,COMMENT orAPPL ACBNAME=A, PASSWORD=B

causes the message to occur.

System Action: Scanning continues. If no additionalerror is detected, NetView Access Services starts. If noother error occurs during NetView Access Servicesprocessing, the return code will be 4 after NetViewAccess Services has terminated.

Operator Response: Read SYSPRINT file and decidewhether the indicated comment is correct or not.

Output: SYSPRINT

EMS0938E TRACES: INTERNAL = xxxxxxx.

Explanation: You have entered the DISPLAYcommand. This message shows the actual setting ofthe internal trace bits, where xxxxxxx is the hexadecimalstring.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0939E RECOVERY =xxxxxxxx.

Explanation: You have entered the DISPLAYcommand. This message shows the actual setting ofthe recovery bits, where xxxxxxxx is the hexadecimalstring.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0940I GARBLED BROADCAST MESSAGE xxxxxxxx WASDELETED.

Explanation: A garbled message was read into themain storage.

System Action: The message was deleted out of mainstorage and out of VSAM.

Operator Response: None.

Output: Console.

EMS0941E DYNAMIC LOAD OF INSTALLATION-WIDE EXITMODULE mmmmmmmm FAILED. RETURN CODE rr,REASON CODE cc.

Explanation: A LOAD for module mmmmmmmm hasfailed. The return code is rr and the reason code is cc.

System Action: The installation-wide exitmmmmmmmm has not been loaded.

Operator Response: Check the steplib for the correctname of the installation-wide exit and rerun the job.

44 NetView Access Services Version 2 Messages

Page 57: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0943I � EMS0968E

EMS0943I VSAM DELETE FOR GARBLED BROADCASTMESSAGE xxxx FAILED.

Explanation: A garbled message was read from aVSAM data set into main storage. The message wasdeleted from main storage, but deletion in VSAM failed.

System Action: The message is deleted from mainstorage.

Operator Response: None.

Output: Console.

EMS0950E SYSPRINT FILE yyyyyyyy CANNOT BE OPENED.

Explanation: The program failed in opening theSYSPRINT file yyyyyyyy.

System Action: NetView Access Services terminates.

Operator Response: See additional messages, andperform problem determination procedure.

Output: Console.

EMS0960E CREATING COMMUNICATION SERVICE SUBTASKHAS FAILED. R15 = nnnnnnnn

Explanation: The ATTACH macro creating communi-cation service failed.

System Action: NetView Access Services terminates.

Operator Response: Determine the contents of reg-ister 15 indicated in the message. Read ATTACHmacro in Supervisor Services and Macro Instructions.

Output: Console.

EMS0961E NOT ALL ASRS ATTACHED. ENTER DISPLAY FORINFO.

Explanation: Not all ASRs specified by SERVRTNstatements in the input parameter file have beenattached successfully.

System Action: Program continues, but the returncode is set to 6.

Operator Response: Enter DISPLAY to receive theinformation on which ATTACHes have failed. Decidewhether it is reasonable to run NetView Access Serviceswithout the failed ASRs or not. If it is not reasonable torun NetView Access Services, enter TERMI.

Output: Console.

EMS0962E COMMUNICATION SERVICE ENDED ABNORMALLY.

Explanation: CS has ended abnormally.

System Action: Program terminates NetView AccessServices.

Operator Response: See additional messages relatingto the error, and follow NetView Access Servicesproblem determination procedure.

Output: Console.

EMS0963A ASR xxxxxxx ABENDED RC = yyyyyyy, ENTER CON-TINUE OR RESTART.

Explanation: An ASR has ended abnormally.

xxxxxxx = SERVRTN nameyyyyyyy = Return code of ASR.

System Action: Program continues.

Operator Response: Either attempt to restart thefailing subtask by entering the RESTART command, orlet NetView Access Services continue processingwithout the failing subtask by entering the CONTINUEcommand.

Output: Console.

EMS0964E RESTARTING ASR xxxxxxxx FAILED. R15 = yyyyyy.

Explanation: The ATTACH for subtask xxxxxx failed.Register 15 contains the ATTACH request return code.

xxxxxxxx = Name of the SERVRTN you have tried to restart.

yyyyyy = Return code from ATTACH request.

System Action: Program continues processing withoutthe ASR.

Operator Response: See ATTACH error code inSupervisor Services and Macro Instructions. Correct theproblem and try to restart the ASR again.

Output: Console.

EMS0965E ASR nnnnnnnn RESTARTED SUCCESSFULLY.

Explanation: You have entered the NetView AccessServices START or RESTART command and the appro-priate application service routine is attached success-fully.

nnnnnnnn = Name of SERVRTN.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0966E TRACE nnnnnnn IS xxx.

Explanation: You have entered the NetView AccessServices TRACE command and the command has beenprocessed successfully.

nnnnnnn = SESSION, RECEIVE, SEND, ERROR, or TIME

xxx = ON or OFF.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0967E TERMQ MODE IS ON.

Explanation: You have entered the TERMQ commandand the command has been processed successfully.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0968E TERMQ MODE IS OFF.

Explanation: You have entered the RESET commandand the command has been processed successfully.

System Action: Program continues.

Operator Response: None.

Output: Console.

Chapter 1. Operator Messages 45

Page 58: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0969E � EMS0981E

EMS0969E ENTER RESTART OR CONTINUE.

Explanation: You have entered a blank line inresponse to message EMS0963A.

System Action: Program continues.

Operator Response: Correct your input.

Output: Console.

EMS0970E ENTER TERMI, TERMQ, RESET, START, DISPLAY ORCANCEL userid,groupid,SESSION=applid.

Explanation: You have entered a blank line as answerto the NetView Access Services ready for commandmessage EMS0990A.

System Action: Program continues.

Operator Response: Correct your input.

Output: Console.

EMS0971E INPUT IGNORED AFTER xxxxxx.

Explanation: A valid command has been processed,but the input following xxxxxx of the command has beenignored.

System Action: Processing continues.

Operator Response: None.

Output: Console and SYSPRINT.

EMS0974E ENTER nnnnnnn IN REPLY TO READY FORCOMMAND MESSAGE.

Explanation: A command can be entered whenprompted.

nnnnnnn = TERMI, TERMQ, RESET, START, DISPLAY, TRACE or CANCEL.

System Action: Program continues.

Operator Response: Enter command when prompted.

Output: Console.

EMS0975E REQUEST nnnnn ACCEPTED.

Explanation: This message informs you that theprogram has accepted your request.

nnnnn = TERMQ or RESET.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0976E COMMAND nnnnnnnn IS UNKNOWN. ENTERRESTART OR CONTINUE.

Explanation: This message is sent as an answer to aninvalid operator command. You have replied to theASR-abended message.

System Action: Program continues.

Operator Response: Correct your input.

Output: Console.

EMS0977E xxxxxxxx IS UNKNOWN. USE TERMI, TERMQ,REFRESH, RESET OR START, DISPLAY, TRACE,RECOVERY OR CANCEL userid,groupid,SESSION=applid.

Explanation: You have entered an unknowncommand.

System Action: Program continues.

Operator Response: Correct your input.

Output: Console.

EMS0978E ENTER yyyyyyyy IN REPLY TO APPROPRIATEASR-ABENDED MESSAGE.

Explanation:

yyyyyyyy = CONTINUE or RESTART.

This message is sent when the operator has enteredyyyyyyyy as reply to the READY FOR COMMANDmessage.

System Action: Program continues.

Operator Response: Enter yyyyyyyy as reply toappropriate ASR-abended message.

Output: Console.

EMS0979E variable text.

Explanation: You have incorrectly entered the TRACEor RECOVERY command. This message indicates theposition at which the command is incorrect and displayspossible valid continuations.

System Action: Program continues.

Operator Response: Enter a valid command.

Output: Console.

EMS0980E TRACES: TERMLU = xxxxxxxx, RELAYLU = xxxxxxxx.

Explanation: You have entered the DISPLAYcommand. This message shows the actual values ofthe TERMLU and RELAYLU keywords, where xxxxxxxxis the LU name or asterisks.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0981E TRACES: NSI = xxx, BUFFSEND = xxx, BUFFREC =xxx, CONF = xxx.

Explanation: You have entered the DISPLAYcommand. This message shows the actual values ofthe trace keywords, where xxx is ON or OFF.

System Action: Program continues.

Operator Response: None.

Output: Console.

46 NetView Access Services Version 2 Messages

Page 59: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0982E � EMS0992E

EMS0982E RECOVERY xxxxxxx ACCEPTED.

Explanation: This message informs you that theentered RECOVERY command has been carried out,where xxxxxxx is the hexadecimal string.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0983E START COMMAND REQUIRES APPLICATIONSERVICE ROUTINE NAME.

Explanation: You have entered START with no name,as reply to the READY FOR COMMAND message.

System Action: Program continues.

Operator Response: Enter START yyyyyyyy.

yyyyyyyy = Valid application service routine name.

Use the DISPLAY command for information.

Output: Console.

EMS0984E APPLICATION SERVICE ROUTINE NAME yyyyyyyy ISUNKNOWN. ENTER DISPLAY FOR INFO.

Explanation: You have entered START yyyyyyyy asreply to the READY FOR COMMAND message, butyyyyyyyy is an invalid application service routine name.

System Action: Program continues.

Operator Response: Enter DISPLAY to get the validASR name and repeat the START command with thevalid ASR name.

Output: Console.

EMS0985E RESTART ASR yyyyyyyy REQUEST ACCEPTED.

Explanation: This message informs you that you haveentered a valid RESTART command, and that theprogram is reattaching the subtask.

yyyyyyyy = ASR name.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0986E TERMQ MODE IS ALREADY xxx.

Explanation: You have entered xxx twice or tried toset the terminate quiesce mode on (off), while terminatequiesce is still on (off).

xxx = ON or OFF.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0988E TRACE nnnnnnnn IS ALREADY xxx.

Explanation: You have entered TRACE nnnnnnnn=xxxtwice or tried to set a TRACE parameter to on (off),while the TRACE parameter is still on (off).

nnnnnnnn = SESSION, TIMER, RECEIVE, SEND, ERROR, NSI, BUFFSEND, BUFFREC, or CONF

xxx = ON or OFF

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0989E TRACE REQUEST xxxxxxx yyy ACCEPTED.

Explanation: This message informs you that theentered TRACE command is being carried out.

xxxxxxx = RESET, TERMLU, RELAYLU, INTERNAL, BUFFSEND, BUFFREC, NSI, CONF, SESSION, RECEIVE, SEND,

ERROR, TIMERyyy = LU name, hexadecimal string, ON,

OFF, NOT

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0990A xxxx READY FOR COMMANDS.

Explanation: This message indicates that NetViewAccess Services now accepts operator commands.Appearing the first time, this message indicates thatNetView Access Services is running. If you enterTERMI, you receive the messageCONFIRM TERMINATION REQUEST BY ENTERINGnnnnn AGAIN. If you reenter TERMI, NetView AccessServices terminates.

xxxx = Network name of this NetView Access Services.

System Action: Program continues.

Operator Response: Enter any valid operatorcommand.

Output: Console.

EMS0991E CONFIRM TERMINATION REQUEST BY ENTERINGtttt AGAIN.

Explanation: You have entered one of the followingcommands:

TERMQ, TQ, TERMI, or TI

This is a prompt to confirm the tttt.

System Action: Program terminates.

Operator Response: Reenter tttt to confirm yourrequest.

Output: Console.

EMS0992E TERMINATE QUIESCE MODE IS xxx.

Explanation: You have entered the DISPLAYcommand. Messages EMS0992E to EMS0995E arewritten to the operator console in response to theDISPLAY command.

xxx = ON or OFF.

System Action: Program continues.

Operator Response: None.

Output: Console.

Chapter 1. Operator Messages 47

Page 60: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS0993E � EMS0999E

EMS0993E TRACES: SESSION = xxx, TIMER = xxx.

Explanation: You have entered the DISPLAYcommand. Messages EMS0992E to EMS0995E arewritten to the operator console in response to theDISPLAY command.

xxx = ON or OFF.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0994E TRACES: RECEIVE = xxx, SEND = xxx, ERROR = xxx.

Explanation: You have entered the DISPLAYcommand. Messages EMS0992E to EMS0995E arewritten to the operator console in response to theDISPLAY command.

xxx = ON or OFF.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0995E ASR nnnnnnnn IS mmm RUNNING pppppppp.

Explanation: You have entered the DISPLAYcommand. Messages EMS0992E to EMS0995E arewritten to the console in response to the DISPLAYcommand.

nnnnnnnn = Name of SERVRTN statementmmm = Not or blankpppppppp = NORMAL, ABNORMAL, ABNRM,

or CO NORMAL if ASR ended normally ABNORMAL if ASR has abended ABNRM, CO if ASR has abended and you entered CONTINUE as reply to appropriate ABEND

message EMS0963A.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0996E HEXSTRING xxxx IS INVALID. ALLOWED VALUESARE 0..9, A..F AND BLANK.

Explanation: You have incorrectly entered the TRACEINTERNAL command.

System Action: Program continues.

Operator Response: Reenter command with validhexadecimal values.

Output: Console.

EMS0997E START ASR yyyyyyyy IGNORED. ASR IS RUNNING.

Explanation: You have entered START yyyyyyyy.

yyyyyyyy = Name of a running ASR.

System Action: Program continues.

Operator Response: None.

Output: Console.

EMS0998E TO RESTART ASR yyyyyyyy, REPLY TO APPRO-PRIATE ABENDED MESSAGE.

Explanation: You have entered START yyyyyyyy,where yyyyyyyy is the name of an abnormally endedASR. Since the operator has not replied to the appro-priate abended message EMS0963A, he is nowprompted to do this.

The operator can only restart an abnormally ended ASRby the START command, if he has entered CONTINUEas reply to the abend message EMS0963A already.

System Action: Program continues.

Operator Response: Enter RESTART as reply toappropriate abended message EMS0963A.

Output: Console.

EMS0999E NV/AS HAS BEEN TERMINATED - RETURN CODE =nn.

Explanation: NetView Access Services has termi-nated.

nn = Return code

Return Code Description00 You have entered the TERMI, TERMQ, or VTAM

HALT NET command.04 A piece of parser information or a warning

message was written to the log-file.06 Either not all ASR has been attached successfully

at startup of NetView Access Services, or an ASRhas ended with a nonzero return code, whileNetView Access Services was running.

08 The parser has written an error message to thelog-file.

10 Open of data set SYSPRINT failed.12 Internal error. Initialization of EMSCINIT failed. A

message is written to the log-file.14 Internal error. EMSCINIT has detected an unre-

coverable error. A message is written to the log-file.

16 Internal error. EMSCINIT has abnormally ended.

Writing this message is the last activity NetView AccessServices performs.

System Action: NetView Access Services terminates.

Operator Response: Analyze the return code.

Output: Console and SYSPRINT.

48 NetView Access Services Version 2 Messages

Page 61: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1001E � EMS1025I

Chapter 2. Administrator and User Messages

EMS1001E Error in structured user data.

Explanation: Invalid structured BIND user datareceived.

System Action: The Logon panel is displayed.

User Response: Log on manually to NetView AccessServices.

EMS1002E Error in unstructured user data.

Explanation: Invalid unstructured BIND user datareceived.

System Action: The Logon panel is displayed.

User Response: Log on manually to NetView AccessServices.

EMS1003E Specify the name of the REXX exec to be started.

Explanation: This message is sent if the EXECcommand is entered without specifying the name of theREXX exec to be started.

System Action: The NetView Access Servicesprogram continues.

User Response: Enter the EXEC command, followedby the name of the REXX exec.

EMS1005E REXX exec nnnnnnnn cannot be started.

Explanation: This message is sent if the EXECcommand is entered with a valid REXX exec name, butthe exec cannot be started.

System Action: The NetView Access Servicesprogram continues.

User Response: None.

EMS1006E The name of the REXX exec must not exceed 8 char-acters.

Explanation: This message is sent if the EXEC orCNEXEC command is entered with a REXX exec nameof more than 8 characters.

System Action: The NetView Access Servicesprogram continues.

User Response: Enter a valid REXX exec name.

EMS1007E Specify the name of the REXX exec to be canceled.

Explanation: You have entered the CNEXECcommand without specifying the name of the REXXexec to be canceled.

System Action: The NetView Access Servicesprogram continues.

User Response: Enter the name of the REXX exec tobe canceled.

EMS1008E REXX exec xxxxxxxx does not exist.

Explanation: A REXX exec with the name you havespecified does not exist.

System Action: The NetView Access Servicesprogram continues.

User Response: Correct your input.

EMS1010A Enter your user ID.

Explanation: You have forgotten to insert your user IDon the panel.

System Action: The Logon panel is redisplayed.

User Response: Reenter logon information with userID.

EMS1011A NetView Access Services time-out has occurred. Toreconnect, enter your password and press Enter.

Explanation: NetView Access Services time-out hasoccurred because you pressed no key on your terminalduring a period specified by the system.

System Action: NetView Access Services displays theLogon panel. All active applications remain active.

User Response: If you want to reconnect to NetViewAccess Services, enter your password and press Enter.

EMS1012A NetView Access Services disconnect has occurred.To reconnect, enter your password and press Enter.

Explanation: You pressed the Disc PF key or issuedthe DISC command on the NetView Access ServicesApplication Selection panel, or issued the DISCcommand together with the command prefix on a panelof an application.

System Action: NetView Access Services displays theLogon panel. All active applications remain active.

User Response: If you want to reconnect to NetViewAccess Services, enter your password and press Enter.

EMS1014A Enter your logon password.

Explanation: You have forgotten to insert your pass-word on the panel.

System Action: The Logon panel is redisplayed.

User Response: Reenter logon information with pass-word.

EMS1025I An interruptive message was indicated but notfound. Reenter your last command.

Explanation: The application is no longer active.

System Action: Program continues.

User Response: Reenter your last command.

Copyright IBM Corp. 1987, 1997 49

Page 62: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1026I � EMS1042E

EMS1026I Messages from nnnnnnnn arrived. Indication modeis ‘J’.

Explanation: You were active on an End User Ser-vices panel and messages from one application withindication mode ‘J’ arrived.

System Action: Program continues.

User Response: None.

EMS1027I Messages from nnnnnnnn arrived.

Explanation: You received messages from an applica-tion with indication mode ‘I’.

System Action: Program continues.

User Response: None.

EMS1028I Several applications sent messages. At least one ofthem has indication mode ‘J’.

Explanation: You received messages from severalapplications. One of them has indication mode ‘J’. Ajump is not processed, because there is more than oneinterruptive application with stored messages.

System Action: Program continues.

User Response: None.

EMS1029I Messages from several applications arrived.

Explanation: You received messages from severalapplications with indication mode ‘I’.

System Action: Program continues.

User Response: None.

EMS1030A Reenter the new password for verification.

Explanation: A new password has been entered andneeds to be reentered to be verified.

System Action: The Logon panel is redisplayed.

User Response: Reenter the new password.

EMS1034E The new password has not been confirmed.

Explanation: The system has tried to verify the newpassword but this one does not match the first one youentered.

System Action: The Logon panel is redisplayed andthe field is cleared.

User Response: Enter both the password and the newpassword again to change it.

EMS1035E You cannot log on at the moment; try again later.

Explanation: NetView Access Services is in terminatequiesce mode.

System Action: The logon request is rejected.

User Response: Try to log on later.

EMS1036E Password update is not supported.

Explanation: A new password has been entered butthe security system does not support passwordupdating.

System Action: The Logon panel is redisplayed.

User Response: Log on to NetView Access Serviceswithout specifying a new password.

EMS1037E Password update is temporarily not possible.

Explanation: NetView Access Services attempted toupdate your password, but due to an internal error thiswas not possible.

System Action: The new password is not updated.

User Response: Change your password at anothertime. If error situation persists, contact your systemsprogrammer.

EMS1038E This user ID is not authorized to log on.

Explanation: The logon authorization exit has deter-mined that you cannot log on using this user ID.

System Action: The Logon panel is redisplayed.

User Response: Log on with a valid user ID.

EMS1039I Secondary authentication verification failed, thelogon is rejected.

Explanation: The logon authorization exit has deter-mined that you cannot log on.

System Action: The logon is rejected.

User Response: Contact your administrator.

EMS1040A Invalid administrator type entered; specify S, G, or B

Explanation: You entered an invalid value in the Typefield. Valid values are S (system), G (group), and B(broadcast); when displaying or listing administrators. Ablank in the Type field is also valid.

System Action: Program continues.

User Response: Correct your input.

EMS1041E Update of Type field not possible; use DELETEcommand followed by an ADD.

Explanation: You attempted to change the authori-zation of an administrator. This cannot be done usingthe UPDATE command. You must first use theDELETE command and then the ADD command.

System Action: Program continues.

User Response: Delete current entry and add a newone.

EMS1042E The password is incorrect; the logon is rejected.

Explanation: The logon authorization exit has deter-mined that this password is illegal.

System Action: The Logon panel is redisplayed.

User Response: Retry logon procedure with validpassword.

50 NetView Access Services Version 2 Messages

Page 63: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1046A � EMS1067E

EMS1046A The password has expired; enter a new password.

Explanation: The logon authorization exit has deter-mined that this password has expired.

System Action: The Logon panel is redisplayed.

User Response: Log on with a valid new password.

EMS1050A The new password has been rejected.

Explanation: The logon authorization exit has deter-mined that this new password is invalid.

System Action: The Logon panel is redisplayed.

User Response: Log on with a valid new password.

EMS1051I Your session with aaaaaaaa was canceled by theoperator.

Explanation: The operator has canceled your sessionwith application aaaaaaaa.

System Action: The Application Selection panel is dis-played.

User Response: Contact the operator.

EMS1054E Your access to the system has been revoked.

Explanation: The logon authorization exit has deter-mined that you can no longer have access to thesystem.

System Action: The Logon panel is redisplayed.

User Response: Contact system support.

EMS1056D The Print key must be a PF key (PFnn), a PA key(PAnn) or blank.

Explanation: You have specified a key other than aPF or PA key for the Print key.

System Action: Program continues.

User Response: Correct your input.

EMS1058E Access control is not active.

Explanation: RACF is either not installed or is unavail-able.

System Action: The Logon panel is redisplayed.

User Response: Contact the operator.

EMS1059E Printers pppppppp and aaaaaaaa are not available.Print request is rejected.

Explanation: The print request is rejected, becauseneither the primary printer pppppppp nor the alternativeVTAM printer aaaaaaaa are available.

System Action: The command is ignored.

User Response: Select another printer.

EMS1060E Print request rejected; selected session is active onanother terminal.

Explanation: The print request is rejected because theselected session is active on another terminal.

System Action: The command is ignored.

User Response: None.

EMS1061E Printer pppppppp is not available. The print request isrejected.

Explanation: Indicates that the printer pppppppp is notavailable to NetView Access Services and the printrequest has been rejected. If the primary VTAM printerand the alternate VTAM printer are not available,pppppppp contains the names of both printers.

System Action: The command is ignored.

User Response: Select another printer.

EMS1062D The value for Virtual Terminal must be Y or N; enterone of these values.

Explanation: You have entered a value other than Yor N for Virtual Terminal.

System Action: Program continues.

User Response: Correct your input.

EMS1063E Printer pppppppp is currently not available. Wait orpress PF3 to cancel the print request.

Explanation: The selected printer ppppppppp is notyet allocated to NetView Access Services. You caneither wait until the printer is allocated or can press PF3to cancel the print request.

System Action: System waits for user response.

User Response: Wait, or Press PF3 to cancel the printrequest.

EMS1064E Panel copy was sent to alternative printer pppppppp.Press PF3 to exit from this panel.

Explanation: The primary VTAM printer was not avail-able and the panel copy was sent to the alternativeVTAM printer. The PF3 key must be pressed to leavethe printer destination panel.

System Action: System waits for user response.

User Response: Press PF3 to leave the panel.

EMS1065E Pass to other location failed.

Explanation: The NetView Access Services requestfor a pass mode session to another location failed.

System Action: The Logon panel is redisplayed.

User Response: Contact your system support.

EMS1066E You are already logged on at another terminal.

Explanation: You do not have multiterminal authori-zation.

System Action: The Logon panel is redisplayed.

User Response: Contact your NetView Access Ser-vices administrator.

EMS1067E This user ID is not known.

Explanation: You are not defined to NetView AccessServices with this user ID.

System Action: The Logon panel is redisplayed.

User Response: Contact your NetView Access Ser-vices administrator.

Chapter 2. Administrator and User Messages 51

Page 64: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1068D � EMS1110E

EMS1068D Invalid REXX exec name.

Explanation: You have entered the name of a REXXexec that is not known.

System Action: Program continues.

User Response: Enter a valid REXX exec name.

EMS1069E The application aaaaaaaa is not known.

Explanation: The selected application is eitherunknown or you are not authorized to use it.

System Action: The Application Selection panel is dis-played.

User Response: Select another application.

EMS1070E The group is either unknown, no applications aredefined to it, or you are not assigned to use applica-tions in it.

Explanation: You are not allowed to use applicationsin this group, it is not recognized, or no applications areassigned to it.

System Action: The Logon panel is redisplayed.

User Response: Check the group you entered andmake sure you enter a group to which you are assignedto use applications.

EMS1071D List request in process. Records read: rrrrrrr.

Explanation: This message is displayed when your listrequest is being processed. It indicates the number ofrecords read.

System Action: Program continues.

User Response: None.

EMS1072E An active free selection application already exists.

Explanation: After disconnecting you entered, on theLogon panel, an application that is allowed as a free-selection application, but you already have an activefree-selection application. It is still active from beforethe disconnect.

System Action: The Application Selection panel is dis-played.

User Response: Log off from the active free-selectionapplication and enter the application you require.

EMS1073E It is not possible to log on at this terminal in thisgroup at the moment; try again. RC= rr.

Explanation: You cannot log on at the moment.

rr = Reason code.

Reason Code Description01 The original terminal is displaying a panel gener-

ated by a REXX exec.02 The original terminal is currently in automatic logon

or logoff processing.03 A full-screen read response is currently out-

standing at the original terminal.04 Another terminal is already in Secure Terminal

processing.

System Action: The logon attempt is rejected.

User Response: Try again later.

EMS1074E You are not defined to this group.

Explanation: The logon authorization exit has deter-mined that you are not defined to this group.

System Action: The Logon panel is displayed.

User Response: Contact your system administrator.

EMS1075E The option for Virtual Terminal must be Y if option Fis specified for Data Compression.

Explanation: You have specified F (inbound and out-bound) for Data Compression. This combination is onlypossible if Y is specified for Virtual Terminal.

System Action: Processing continues.

User Response: Correct your input.

EMS1076E Recursive logon to same group is not allowed.

Explanation: You selected the same NetView AccessServices on your Application Selection panel that youare already in. NetView Access Services displayed theLogon panel and you tried to log on with the same userID to the same group. This is not possible.

System Action: The logon request is rejected.

User Response: Log on with another group or pressthe Escape key to return to your original ApplicationSelection panel.

EMS1078E Your access to this group has been revoked.

Explanation: The logon authorization exit routine hasdetermined that your access to this group has beenrevoked.

System Action: The Logon panel is displayed.

User Response: Contact your system administrator.

EMS1090E You are not authorized to use this terminal.

Explanation: The logon authorization exit has deter-mined that you are not authorized to use this terminal.

System Action: The Logon panel is displayed.

User Response: Contact your system administrator.

EMS1094E You are not authorized to use this application.

Explanation: The logon authorization exit routine hasdetermined that you are not authorized to use this appli-cation.

System Action: The Logon panel is displayed.

User Response: Contact your system administrator.

EMS1110E You have already logged on to your maximumnumber of applications.

Explanation: You cannot start any more sessions asthe maximum number allowed to you has already beenconnected.

System Action: The Application Selection panel isredisplayed.

User Response: Log off an application to free asession you want to use, or ask your administrator toincrease your number of allowable sessions.

52 NetView Access Services Version 2 Messages

Page 65: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1111E � EMS1116E

EMS1111E Reconnection to application aaaaaaaa not authorizedfrom this terminal.

Explanation: The reselection exit EMSESREX deter-mined that you are not authorized to gain access to thenamed application from your terminal.

System Action: The Application Selection panel isredisplayed.

User Response: Return to your original terminal togain access to the application, or issue the LF commandto terminate the session.

EMS1112E The nnnnnnnn data stream exceeds the capabilities ofthis terminal. Try another terminal or log off. ( rr)

Explanation: Application nnnnnnnn sent a 3270 datasteam, which this terminal is not capable of displaying.This can happen if this terminal assumed a sessionfrom, or shared a session with, a terminal that wascapable of displaying the 3270 data stream.

rr = Reason code.

Reason Code Description01 Screen size changed in BIND data, but the ter-

minal does not support alternative screen size.02 The application sent an erase/write, but the default

screen size of the terminal is less than the defaultscreen size of the application.

03 The application sent an erase/write alternative, butthe alternative screen size of the terminal is lessthan the alternative screen size of the application.

04 The model terminal names are not the same.05 The application uses Load Symbols structured

fields, but this is not supported by the terminal.06 The application uses Vector Graphics. but this is

not supported by the terminal.07 The application uses Destination Origin structured

fields, but this is not supported by the terminal.08 The application uses PCLK structured fields, but

this is not supported by the terminal. Graphics isin use, but is not supported by the terminal.

09 The application uses Create Partition structuredfields, but this is not supported by the terminal.

10 Incompatible screen sizes. The screen size of thisterminal is less than the original terminal.

11 Incompatible screen sizes. This terminal and theoriginal terminal support different columns.

12 Load PS incompatibility.13 Vector (APA) graphic incompatibility.14 GDDM* incompatibility.15 Extended mode incompatibility.16 Create partition incompatibility.17 VAG code. Graphics is in use, but is not sup-

ported by the terminal.18 VAG code. Loadable color table is in use, but is

not supported by the terminal.19 VAG code. Loadable line types are in use, but are

not supported by the terminal.20 LPS code. At least one RWS is in use by the

application that is not supported by this terminal.21 LPS code. At least one RWS is in use by the

application that is a nonloadable RWS on the ter-minal device.

22 LPS code. MULTID is in use by the application,but is not supported by the terminal.

23 LPS code. DBCS RWS is in use by the applica-tion, but is not supported by the terminal device.

24 LPS code. Multiple planes for at least one RWSare used by the application, but are not supportedby the terminal device.

25 LPS code. Dynamic-storage assigned RWSs areused by the application, but are not supported bythe terminal device.

26 GDDM not supported.

System Action: Program continues, application data issaved.

User Response: Log on at a terminal with enhancedcapabilities and try to assume or share a session at thatterminal. Otherwise, log off from the application usingthe NetView Access Services LF command.

EMS1113E The terminal your partner is using is not capable ofdisplaying the data stream. The session is canceled.

Explanation: The application you are sharing with yourpartner sent data that the terminal is not capable of dis-playing. This can happen if you established a sharedsession and your terminal is capable of displaying thedata stream, but the terminal your partner is using isnot.

System Action: Program continues, application data issaved.

User Response: Notify your partner and both use ter-minals that are capable of displaying the data stream.

EMS1114E You are not authorized to use terminal assume.

Explanation: You are not authorized for terminalassume.

System Action: The Application Selection panel is dis-played.

User Response: Contact your group administrator.

EMS1115E You are not authorized to use this application inpass mode.

Explanation: You tried to select an application in passmode, but you are not authorized to use this applicationin pass mode.

System Action: The Application Selection panel isredisplayed.

User Response: Use the application in relay mode, orcontact your group administrator.

EMS1116E You are not authorized to use this application inrelay mode.

Explanation: You have tried to select an application inrelay mode, but you are not authorized to use this appli-cation in relay mode.

System Action: The Application Selection panel is dis-played.

User Response: Use the application in pass mode, orask your group administrator for authorization to userelay mode.

Chapter 2. Administrator and User Messages 53

Page 66: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1117E � EMS1128E

EMS1117E INFO command not supported.

Explanation: The INFO command has been enteredand is not supported.

System Action: The Application Selection panel is dis-played.

User Response: See your system administrator.

EMS1118E This terminal type is incompatible with existingapplication session.

Explanation: You selected an application with terminalassume but the second terminal type is incompatiblewith the first.

System Action: The Application Selection panel is dis-played.

User Response: Select the application on a terminaltype that corresponds to the first terminal type.

EMS1119E Access to system application is not possible; nodefinition for it exists.

Explanation: The application is not defined to thesystem and cannot be selected. It might have beendeleted since you logged on to NetView Access Ser-vices.

System Action: The Application Selection panel is dis-played.

User Response: See the system administrator to seeif this application can be set up to be used.

EMS1120E System is in quiesce mode; try again later.

Explanation: The system is in quiesce mode. Proc-essing cannot continue. You can only use applicationsthat are already active.

System Action: The Application Selection panel isredisplayed.

User Response: Try to select the application later.

EMS1121E BIND user data too large to process.

Explanation: The system cannot handle BIND userdata longer than 256 bytes; the request has beenrejected.

System Action: The Application Selection panel is dis-played.

User Response: Ask your system administrator tocheck the length of the BIND user data.

EMS1122E Logoff is in progress; try again later.

Explanation: You had a multiterminal session withNetView Access Services, and logged off at one ter-minal. At another terminal in the multiterminal sessionyou tried to select an application, but NetView AccessServices is about to log off, so processing cannot con-tinue.

System Action: The Application Selection panel is dis-played.

User Response: Try to select the application later.

EMS1123E Maximum number of sessions for this applicationhas been reached.

Explanation: No more sessions with this applicationcan be established.

System Action: The Application Selection panel is dis-played.

User Response: Ask your system administrator toincrease the value of the maximum sessions for theapplication.

EMS1124E This application is already in pass mode.

Explanation: You are in a multiterminal session andtried to assume an application. The application hasalready been selected in pass mode, at another ter-minal, and therefore cannot be assumed.

System Action: The Application Selection panel is dis-played.

User Response: No action is possible until the appli-cation has been dropped.

EMS1125E This application is already in relay mode.

Explanation: The application has already beenselected in relay mode, so you cannot assume it in passmode at another terminal.

System Action: The Application Selection panel is dis-played.

User Response: Log off from the application and rese-lect it, if you want to use it in pass mode.

EMS1126E A valid group name must be entered when Type=G isspecified.

Explanation: When Type=G is specified, the systemexpects a group administrator to be defined. You mustenter the name of the group.

System Action: Program continues.

User Response: Enter the name of an existing group.

EMS1127E An ambiguous LIST request was specified; eitherspecify Type=G or leave the Group field empty.

Explanation: You entered conflicting values. Todefine a system administrator, enter S in the Type fieldand leave the Group field blank. To specify a groupadministrator, enter G in the Type field and the name ofthe group in the Group field.

System Action: Program continues.

User Response: Correct your input.

EMS1128E Incorrect or no administrator type specified.

Explanation: You entered an incorrect administratortype in the Type field, or left it blank. When therequested function is ADD or UPDATE, valid values inthe Type field are S, G, or B. A blank is also valid forDISPLAY, LIST, or DELETE,

System Action: Program continues.

User Response: Correct your input.

54 NetView Access Services Version 2 Messages

Page 67: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1129E � EMS1171D

EMS1129E Enter the user ID of the group administrator whosegroups are to be listed.

Explanation: You issued the LIST request withType=G, but you did not enter the user ID of the groupadministrator.

System Action: Program continues.

User Response: Correct your input.

EMS1159E There are no group administrators defined for thespecified group.

Explanation: You issued a LIST command on theDefine an Administrator panel, put a question mark inthe User field, and filled in the Group field, but noadministrator has been defined for this group.

System Action: Program continues.

User Response: None.

EMS1160E No Copy commands are allowed during recording.

Explanation: If you are recording logon or logoffsequences, no copy commands are allowed.

System Action: You are forced to the ApplicationSelection panel, where this message is displayed. Therecording is terminated.

User Response: Start recording again.

EMS1161E The specified application is not defined to a user inthis group (or the group is not of type N).

Explanation: An administrator issued a LIST commandon the Assign a User to a Group panel and filled in theApplication field and the Group field, and entered aquestion mark in the User field, but no user has accessto the specified application in this group.

System Action: Program continues.

User Response: None.

EMS1163E Session with application nnnnnnnn has beendropped.

Explanation: An error indicator or a deallocationrequest was received for this application.

nnnnnnnn = Application name.

System Action: The Application Selection panel is dis-played showing this message.

User Response: None.

EMS1164E Pass mode logon request failed for applicationaaaaaaaa.

Explanation: A request for a pass mode logon failed.

System Action: NetView Access Services displays theApplication Selection panel.

User Response: Contact the operator.

EMS1166E Relay mode logon request failed for applicationaaaaaaaa.

Explanation: A request for a relay mode session withthe specified application failed due to network con-straints.

System Action: NetView Access Services displays theApplication Selection panel.

User Response: Contact the operator.

EMS1167E The specified application is not defined to a user.

Explanation: You issued a LIST command on theAssign a User to a Group panel, and filled in the fieldsas required, but no user in the system has access to thespecified application.

System Action: Program continues.

User Response: None.

EMS1168E The specified application is not defined to a user inyour type N groups.

Explanation: You issued a LIST command on theAssign a User to a Group panel, and filled in the fieldsas required, but no user in your groups has access tothe specified application.

System Action: Program continues.

User Response: None.

EMS1169E The specified application is not defined to this userin your groups.

Explanation: You issued a LIST command on theAssign a User to a Group panel and filled in the Applica-tion field and the User field, but this user does not haveaccess to the specified application in any of yourgroups.

System Action: Program continues.

User Response: None.

EMS1170E The specified user is not a member of your groups.

Explanation: You issued a LIST command on theAssign a User to a Group panel and filled in the Userfield, but this user is not in any of the groups you admin-ister.

System Action: Program continues.

User Response: None.

EMS1171D No BIND user data found for the specified System-Internal Name.

Explanation: No record with the specified key valuecould be found because either you misspelled the keyvalue, or no BIND user data has been defined for thisapplication.

System Action: Program continues.

User Response: Check what you entered and makesure you typed everything correctly.

Chapter 2. Administrator and User Messages 55

Page 68: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1172D � EMS1183A

EMS1172D BIND user data already exists for the specifiedSystem-Internal Name.

Explanation: The request to add an entry failedbecause it already exists.

System Action: Program continues.

User Response: Check what you entered and makesure you typed everything correctly.

EMS1173E Ambiguous LIST request specified; either specifyType=G or leave the User field empty.

Explanation: Conflicting values were entered. To listall groups for which the user is a group administrator, fillin the User field and specify Type=G. To list all groupsdefined to the system, leave the User field blank andspecify Type=G.

System Action: Program continues.

User Response: Correct your input.

EMS1174E Leave the Type field empty or specify Type=G plus auser ID in the User field.

Explanation: You entered Type=G plus User=? to listgroup administrators, but you did not enter the name ofthe group in the Group field.

System Action: Program continues.

User Response: Correct your input.

EMS1175E The specified administrator is not known.

Explanation: You issued a LIST command on theDefine an Administrator panel and filled in the User field,but the specified user is not defined as an administrator.

System Action: Program continues.

User Response: None.

EMS1176E No applications are defined for this group.

Explanation: You issued a LIST command on theAssign an Application to a Group panel and wanted tolist all applications that are already defined to thatgroup, but there were no applications defined.

System Action: Program continues.

User Response: None.

EMS1177E No applications are defined for users in this group(or group is not of type N).

Explanation: You issued a LIST command on theAssign a User to a Group panel and wanted to list allapplications that are already defined to users, but therewere no applications defined. The search is limited toNormal groups.

System Action: Program continues.

User Response: None.

EMS1178E No users are defined in this group (or group is not oftype N).

Explanation: You issued a LIST command on theAssign a User to a Group panel and wanted to list allusers in a specified group, but there were no usersdefined in this group. The search is limited to Normalgroups.

System Action: Program continues.

User Response: None.

EMS1179E Session not established. Reason: You are not loggedon to this application.

Explanation: The requesting user is not logged on tothe selected application.

System Action: Program continues.

User Response: Log on to the application and startthe shared session request again.

EMS1180I Wait for answer or press End PF key to cancelshared session request. Data and commands canonly be entered by you.

Explanation: This message is displayed on the SharedSession Request panel for Shared Mode equals S(Show). It remains until the shared session is estab-lished.

System Action: Program continues.

User Response: None.

EMS1181I Wait for answer or press End PF key to cancelshared session request. Data and commands canonly be entered by your partner.

Explanation: This message is displayed on the SharedSession Request panel for Shared Mode equals F(Forward). It remains until the shared session is estab-lished.

System Action: Program continues.

User Response: None.

EMS1182A Fill in the password if required and press ENTER toaccept shared session. Data and commands canonly be entered by you.

Explanation: This message is displayed on the SharedSession Response panel for Shared Mode equals F(Forward). It remains until the shared session is estab-lished.

System Action: Program continues.

User Response: Fill in the password, if required, andpress ENTER to accept the shared session.

EMS1183A Fill in the password if required and press ENTER toaccept shared session. Data and commands canonly be entered by your partner.

Explanation: This message is displayed on the SharedSession Response panel for Shared Mode equals S(Show). It remains until the shared session is estab-lished.

System Action: Program continues.

56 NetView Access Services Version 2 Messages

Page 69: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1184E � EMS1199D

User Response: Fill in the password, if required, andpress ENTER to accept the Shared Session.

EMS1184E Session not established. Reason: Your partner is notlogged on. Try later.

Explanation: Your partner is not logged on.

System Action: Program continues.

User Response: Try again later when your partner islogged on.

EMS1185E Session not established. Reason: Your partner hasrejected the request to share a session.

Explanation: Your partner has rejected the request toshare the session.

System Action: Program continues.

User Response: Contact your partner.

EMS1186I You canceled the request to share a session.

Explanation: You pressed the End PF key whilewaiting for your partner to accept the request to share asession. The establishment of the Shared Session iscanceled.

System Action: Program continues.

User Response: Try again.

EMS1187I Your partner canceled the shared session.

Explanation: Your partner has canceled the sharedsession. This message is displayed to the user whohas not canceled the shared session.

System Action: Program continues.

User Response: None.

EMS1188I You pressed a wrong PF key. Wait for answer orpress End PF key to cancel the shared session.

Explanation: You have pressed a wrong PF key whilerequesting a shared session.

System Action: Program continues.

User Response: Wait for answer or press End PF Keyto cancel the Shared Session request.

EMS1189I You pressed a wrong PF key.

Explanation: You pressed a wrong PF key on theShared Session Response panel.

System Action: Program continues.

User Response: None.

EMS1190D The selection ID must be 0 for the free selectionapplication.

Explanation: You tried to change the Selection ID of afree selection application. Only 0 is allowed.

System Action: Program continues.

User Response: Change the Selection ID back to 0.

EMS1191E Ambiguous LIST request; specify Type=G or leavethe Group field empty.

Explanation: Conflicting values were entered: a listrequest for group administrators is identified byGroup=group ID and User=? or User=blank.

System Action: Program continues.

User Response: Correct your input.

EMS1192E Record not found in profile.

Explanation: The specified record has been found instorage but not on VSAM data sets. This is probably aproblem with the VSAM data sets. Check for additionalVSAM messages. If you share profiles between twoNetView Access Services systems, this record couldhave been deleted in one system and therefore on theVSAM data sets. But it still remains in the storage ofthe other NetView Access Services system.

System Action: The specified action is not performed.

User Response: Contact the operator.

EMS1193E This command is not applicable for public groups.

Explanation: You tried to use the ADD or DELETEcommand for a public group. Public groups do notrequire each user to be defined.

System Action: Program continues.

User Response: None.

EMS1194D System-Internal Name must be blank for the freeselection application.

Explanation: You specified a system-internal name forthe free selection application. This is not possible. Itmust be blank. The group-wide application name mustbe eight dots (“........”).

System Action: The specified action is not performed.

User Response: Blank out the system-internal name.

EMS1197E You are not authorized to issue selective broadcastmessages.

Explanation: You have entered the BMSG command,but you are not authorized to use this function.

System Action: Program continues.

User Response: None.

EMS1199D You cannot use the ADM command when you aredefined to a public group.

Explanation: You are currently logged on in a Public(type P) group. The default access parameters (speci-fied by the system administrator) for a Public groupcannot be changed. If you are a system administrator,you can change the access parameters of a publicgroup by logging onto a normal or external group anddoing the administration there.

System Action: Program continues.

User Response: None.

Chapter 2. Administrator and User Messages 57

Page 70: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1200E � EMS1212E

EMS1200E cccccc request not performed, UPDATE in progress;try again.

Explanation: An update process is in progress, there-fore the request cannot be performed now.

cccccc represents the command that you entered.

System Action: Program continues.

User Response: Set up the request again.

EMS1201I The kkkkk key is not supported on this panel.

Explanation: You pressed a key other than ENTER, ora PF key for End or Help.

System Action: Program continues.

User Response: Use the correct key.

EMS1202D Default Group must be blank for cccccc.

Explanation: The already defined attribute is assumedfor each user. cccccc is either ADD or UPDATE.

System Action: Program continues.

User Response: Blank out the Default Group field.

EMS1203D The cccccc command is not supported on this panel.

Explanation: The entered command is probably anadministrator command.

cccccc is the command.

System Action: Wait for a valid command.

User Response: Use one of the function commands.

EMS1204D This command is not known.

Explanation: The command entered was not aNetView Access Services command.

System Action: Program continues.

User Response: Enter a valid command.

EMS1205A Press ENTER to confirm the cccccc request.

Explanation: For an ADD, DELETE, or UPDATEcommand, confirmation is required.

cccccc represents the request to be confirmed.

System Action: Program continues.

User Response: Either press ENTER to get therequest processed, or enter any other key to terminatethe request and return without any action.

EMS1206D This action is not applicable for this function.

Explanation: The command you entered is not valid.

System Action: Program continues.

User Response: Enter a command according to thefunction. That is: ADD, DELETE, UPDATE, LIST,DISPLAY, HELP, or END.

EMS1207D You can only enter one of the commands displayedabove, or HELP or END.

Explanation: The entered command is probably afunction command.

System Action: Program continues.

User Response: Enter a valid command for thedesired action.

EMS1208E cccccc request has been processed successfully.

Explanation: An ADD, DELETE, or UPDATEcommand has been processed successfully.

cccccc is the command.

System Action: Program continues.

User Response: None.

EMS1209E cccccc request not confirmed, function canceled.

Explanation: An ADD, DELETE, or UPDATE requesthas not been confirmed by pressing ENTER. The func-tion has terminated without any action. Data isunchanged.

cccccc represents the request.

System Action: Program continues.

User Response: None.

EMS1210E Application nnnnnnnn is in session with tttttttt.

Explanation: This message is in response to a PDcommand for a pass mode application.

nnnnnnnn = Application nametttttttt = SLU.

System Action: Program continues.

User Response: None.

EMS1211E No active session with application nnnnnnnn.

Explanation: This message is in response to a PDcommand.

nnnnnnnn represents the application identifier.

System Action: Program continues.

User Response: None.

EMS1212E Application nnnnnnnn, LUNAME= llllllll,SESSION=ssssssss, MODNAME=mmmmmmmm.

Explanation: This message is in response to a PDcommand.

nnnnnnnn = Application identifier.ssssssss = Status that might be:

Active Inactive

IIP - initiation in progressIRQ - initiation request queuedTRQ - termination request queuedTIP - termination in progressUnknown to VTAM

llllllll = Logical unit namemmmmmmmm = Name of the LOGMODE.

System Action: Program continues.

User Response: None.

58 NetView Access Services Version 2 Messages

Page 71: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1213E � EMS1224D

EMS1213E Another free selection application is already active.

Explanation: The free selectable application field con-tains already an active application.

System Action: The Application Selection panel is dis-played.

User Response: Log off this application, then enteranother free selectable application.

EMS1214D Logoff for pass mode applications is not allowed.

Explanation: You have a multiterminal session, andare using an application in pass mode on one terminal.You tried to log off from the pass-mode applicationusing the LF command on another terminal, but this isnot possible.

System Action: Program continues.

User Response: None.

EMS1215E You are not a group administrator for groupgggggggg.

Explanation: You are not a group administrator for thegroup and are therefore not authorized to perform thisfunction. gggggggg is the group name.

System Action: Program continues.

User Response: Check the group ID that you enteredor see your system administrator.

EMS1216E uuuuuuuu is not a group administrator for groupgggggggg.

Explanation: User uuuuuuuu is not a group adminis-trator for this group.

uuuuuuuu = User IDgggggggg = Group name.

System Action: Program continues.

User Response: None.

EMS1217E cccccc request: nn application(s) processed.

Explanation: An ADD or DELETE ALL command hasbeen processed successfully.

cccccc is the command.

nn represents the number of applications that have beenadded or deleted.

System Action: Program continues.

User Response: None.

EMS1218D The specified input is not valid.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Correct the data in the field wherethe cursor is positioned.

EMS1219D This is not a valid ID number of a function.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Enter one of the function IDs shownon the panel.

EMS1220D The specified application is not known.

Explanation: The application is not defined to NetViewAccess Services.

System Action: Program continues.

User Response: Check what you entered as an appli-cation name, and see your group administrator.

EMS1221E The application nnnnnnnn can be selected now.

Explanation: The application is now selectable on yourApplication Selection panel.

System Action: Program continues.

User Response: Select application, if desired.

EMS1222D The Pseudo Terminal Name must be blank forcccccc.

Explanation: The pseudo terminal name must beblank if you want to add or update all applications forone user or one application for all users.

cccccc is request type ADD ALL or UPD ALL.

System Action: The specified request is not proc-essed.

User Response: Blank out the pseudo terminal name.

EMS1223D This terminal prefix is equal to or similar to the ter-minal prefix of tttttttt.

Explanation: The same terminal prefix is defined formore than one application. There are certain caseswhere you must not define equal or similar pseudo ter-minal prefixes.

tttttttt is the system-internal name of an application.

If both ACBs are shared and they have different PLUnames but have equal prefixes, you get this message.

If one is shared and one is unique it does not matterwhether they have the same PLU name or not. If theyhave equal prefixes you get this message.

If both are unique it does not matter if they have thesame PLU name or not, if one prefix includes the otherbut is not equal to it, you get this message.

System Action: Program continues.

User Response: Change the prefix.

EMS1224D Access Mode must be blank for an ADDALL.

Explanation: The defined access mode for each appli-cation is taken from the system or group definition.

System Action: Program continues.

User Response: Blank out the Access Mode.

Chapter 2. Administrator and User Messages 59

Page 72: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1225D � EMS1237D

EMS1225D User = * and application = * is not allowed.

Explanation: Only one action at a time. Either add allapplications for one user or add one application for allusers.

System Action: Program continues.

User Response: Change one of the asterisks to avalid name.

EMS1226E cccccc request has been processed successfully: IDchange effective from next user logon.

Explanation: An update of the Selection ID has beenprocessed successfully. The stored Selection ID doesnot match that shown on the Application Selectionpanel. It is activated only after the user logs off.

cccccc is the command.

System Action: Program continues.

User Response: Log off from NetView Access Ser-vices to activate the new Selection ID.

EMS1227E Caution: Selection ID on this panel does not matchthat shown on the Application Selection panel.

Explanation: The Selection ID of this application hasbeen updated since the last logoff. It does not matchthe one shown on the Application Selection Panel.

System Action: Program continues.

User Response: Log off from NetView Access Ser-vices to activate the new Selection ID.

EMS1228D Enter ? in the key field of your choice to get a list.

Explanation: The LIST command was specified andno question mark was entered in a key field to indicatethe required list.

System Action: Program continues.

User Response: Enter a question mark in the field forwhich the list should be built.

EMS1229D Enter ? in only one key field.

Explanation: There were too many question marksspecified. Only one is permitted in a key field to get thecorrect list information.

System Action: Program continues.

User Response: Blank out all question marks untilonly one remains.

EMS1230E Internal error has occurred.

Explanation: An internal error has occurred. Themodule detecting this error issues a message to theoperator console, which describes the error in moredetail.

System Action: Depending on the error, processingeither continues or the function is canceled.

User Response: Contact the operator for details.

EMS1231D The specified application is not defined to thesystem.

Explanation: NetView Access Services does not rec-ognize the application.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1232D An application with the specified System-InternalName already exists.

Explanation: The request to add an entry failedbecause it already exists.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1233D The specified System-Internal Name has been addedto disk only.

Explanation: The request to add an entry has beenprocessed on disk only. The extension for an in-storageadd failed because of a GETMAIN error.

System Action: Program continues.

User Response: Contact system support.

EMS1234D The application has been added, but the maximumsessions are set to zero.

Explanation: The request to add an entry has beenprocessed on disk and in storage. Maximum number ofsessions has been set to zero because of a GETMAINerror.

System Action: Program continues.

User Response: Contact system support.

EMS1235D The application has been updated on disk only.

Explanation: The request to update an entry has beenprocessed on disk only. The extension for in-storageadd failed because of a GETMAIN error.

System Action: Program continues.

User Response: Contact system support.

EMS1236D The application has been updated, but the maximumsessions are not changed.

Explanation: The request to update an entry has beenprocessed on disk and in storage. The extension ofmaximum sessions was not possible because of aGETMAIN error.

System Action: Program continues.

User Response: Contact system support.

EMS1237D The specified System-Internal Name is not valid.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

60 NetView Access Services Version 2 Messages

Page 73: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1238D � EMS1252D

EMS1238D The primary LU name is not valid; enter a validname.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1239E List request could not be satisfied; no data found tobuild a list.

Explanation: You tried to get a list, but no data wasavailable.

System Action: Program continues.

User Response: None.

EMS1240D The option for automatic logon must be Y or N; enterone of these values.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1241D The ACB type must be I, U, S, or N; enter one ofthese values.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1242D The access mode must be R, P, or B; enter one ofthese values.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1243D The number of alternative sequences must be 0 - 10;enter a number within this range.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1244D The specified Idle Time value is not valid.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1245D The specified Pseudo Terminal Prefix is not valid.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1246D The value of maximum sessions must be 0 - x; entera number within this range.

Explanation: The syntax of the entered value is notcorrect. NetView Access Services checks the numbersof characters in the Pseudo Terminal Prefix and gets xfrom that, if the ACB type specified is unique or indi-vidual.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1247D The specified user is not a member of this group.

Explanation: The user that was entered cannot befound. Either it was spelled incorrectly or no user isdefined with this name.

System Action: Program continues. The requestcannot be performed.

User Response: Verify and correct entered data.

EMS1248D The specified user is already defined as an adminis-trator.

Explanation: The request to add an entry failedbecause it already exists.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1249E The specified user is not defined as a system orbroadcast administrator.

Explanation: You have requested to delete a systemor broadcast administrator, but no entries exist.

System Action: Program continues.

User Response: Correct your input.

EMS1250D Specify an application by ID or name.

Explanation: Some input is missing: a command thatrequired an application was entered without an applica-tion.

System Action: Program continues. The requestcannot be performed.

User Response: Enter the command with an applica-tion name.

EMS1251D The specified user ID is not valid.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1252D The specified group name is not valid.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

Chapter 2. Administrator and User Messages 61

Page 74: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1253E � EMS1269D

EMS1253E There are no applications defined for you.

Explanation: You logged on as an administratorwithout having any application in this group.

System Action: Program continues.

User Response: Define some applications for yourself.

EMS1254D There are no applications defined for this group.

Explanation: No applications have been assigned tothe group.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1255E The specified group already exists.

Explanation: The request to add an entry failedbecause it already exists.

System Action: Program continues.

User Response: None.

EMS1256D The specified group is added on disk only.

Explanation: The request to add an entry has beenprocessed on disk only. The extension for in-storageupdate failed because of a GETMAIN error.

System Action: Program continues.

User Response: Contact system support.

EMS1257D The specified group is updated on disk only.

Explanation: The request to update an entry has beenprocessed on disk only. The extension for in-storageupdate failed because of a GETMAIN error.

System Action: Program continues.

User Response: Contact system support.

EMS1258D The group type must be N, P or E; enter one of thesevalues.

Explanation: The group type has been entered incor-rectly.

System Action: The Define a Group panel is redis-played.

User Response: Correct the value of the group type.

EMS1259D The number of sessions must be 1 - 99; enter anumber within that range.

Explanation: The value entered is not between 1 and99.

System Action: Program continues.

User Response: Correct your input.

EMS1260D The option for multiterminal use must be Y, N, or S;enter one of these values.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Correct your input.

EMS1261D The Escape key must be a PA key (PA nn), a PF key(PFnn), the ATTN key (ATTN) or blank.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Correct your input.

EMS1262D The Command key must be a PF key (PF nn) or theEnter key (ENTR).

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Correct your input.

EMS1263D The specified command prefix is not valid.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1264D The specified CopyFrom-begin key must be a PF key(PFnn).

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Correct your input.

EMS1265D The specified CopyFrom-end key must be a PF key(PFnn).

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Correct your input.

EMS1266D The specified CopyTo key must be a PF key (PF nn).

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Correct your input.

EMS1268D The specified application already belongs to thisgroup.

Explanation: The request to add an entry failedbecause it already exists.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1269D The specified application is added to this group ondisk only.

Explanation: The request to add an entry has beenprocessed on disk only. The extension for in-storageadd failed because of a GETMAIN error.

System Action: Program continues.

User Response: Contact system support.

62 NetView Access Services Version 2 Messages

Page 75: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1270D � EMS1284D

EMS1270D The specified application in this group is updated ondisk only.

Explanation: The request to update an entry has beenprocessed on disk only. The extension for in-storageadd failed because of a GETMAIN error.

System Action: Program continues.

User Response: Contact system support.

EMS1271D The specified group has not been defined.

Explanation: The group is not defined to NetViewAccess Services.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1272D The specified application name is not valid.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1273D cccccc ALL request for nnnn user(s) processed.

Explanation: The specified application has beenadded or updated for nnnn users in the specified group.

cccccc = ADD or UPDATEnnnn = Number of users processed.

System Action: The action is performed.

User Response: None.

EMS1274D The specified application does not belong to thisgroup.

Explanation: Either the application is not in the group,or you spelled it incorrectly.

System Action: Program continues. The requestcannot be performed.

User Response: Verify and correct entered data.

EMS1275D The system definition for the specified applicationdoes not exist.

Explanation: Either the application has not beendefined to the system, or has been deleted recently.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1276D The logon profile type must be S or G; enter one ofthese values.

Explanation: Either you have not filled in the field, orthe syntax of your entered value is incorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1277D The Jump key must be a PA key (PA nn), a PF key(PFnn), the ATTN key (ATTN), or blank.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1278D The specified application is not defined for this user.

Explanation: The application cannot be found for thisuser. Either something is spelled incorrectly, or theapplication does not exist.

System Action: Program continues.

User Response: Verify and correct entered data.

| EMS1279D The specified application is already defined for this| user.

Explanation: The request to add an entry failedbecause it already exists.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1280D The specified application does not exist in thisgroup.

Explanation: The application is not defined to thisgroup.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1281D The system definition for the specified applicationdoes not exist.

Explanation: The application has not been defined tothe system.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1282D The option for Default Group must be Y or N; enterone of these values.

Explanation: Either you have not filled in the field, orthe syntax of your entered value is incorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1283D The specified Pseudo Terminal Name is not valid.

Explanation: The syntax of the entered value is notcorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1284D The option for Record Authorization must be Y or N;enter one of these values.

Explanation: Either you have not filled in the field, orthe syntax of your entered value is incorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

Chapter 2. Administrator and User Messages 63

Page 76: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1285D � EMS1298E

EMS1285D The option for Terminal Assume must be Y, N, or C;enter one of these values.

Explanation: Either you have not filled in the field, orthe syntax of your entered value is incorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1286D The specified application is not defined for you inthis group.

Explanation: You are not authorized to use this appli-cation in this group.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1287D No system definition exists for the specified applica-tion in the group.

Explanation: The application has not been defined tothe system.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1288D The selection ID must be 1 - 99 or blank.

Explanation: You have not entered the correct valuefor this field.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1289D The option for Default Application must be Y or N;enter one of these values.

Explanation: Either you have not filled in the field, orthe syntax of your entered value is incorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1290D The option for Logon Profile must be S, G or U;enter one of these values.

Explanation: Either you have not filled in the field, orthe syntax of your entered value is incorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1291D The Active Profile must be 1 or 2; enter one of thesevalues.

Explanation: Either you have not filled in the field, orthe syntax of your entered value is incorrect.

System Action: Program continues.

User Response: Verify and correct entered data.

EMS1292D No application with the specified System-InternalName exists.

Explanation: BIND user data can only be defined toexisting system applications. No application has beendefined to NetView Access Services with the system-internal name you specified.

System Action: Program continues.

User Response: The value you entered might havebeen left blank or misspelled. You can list the applica-tions defined to the system using option 4 of the Admin-istration Selection panel.

EMS1293D Enter your BIND user data.

Explanation: BIND user data field must be filled.

System Action: Program continues.

User Response: Enter data as required.

EMS1294E The specified user is not known (in a type N group).

Explanation: This message is for system administra-tors only: The system administrator issued a LISTcommand on the Assign a User to a Group panel andfilled in the User field, but this user is not defined in anygroup.

System Action: Program continues.

User Response: None.

EMS1295E The request has been processed successfully.

Explanation: The broadcast message has beenchanged successfully.

System Action: Program continues.

User Response: None.

EMS1296E cccccccc ALL request: ALL applications processed.

Explanation: All applications for the specified user inthe specified group have been deleted.

cccccc = DELETE or UPDATE.

System Action: Program continues.

User Response: None.

| EMS1297E The specified application does not exist for this user.

Explanation: This message is only for systemadministrators: The specified application is not definedto this user in any group.

System Action: Program continues.

User Response: None.

EMS1298E The specified application does not exist for thisgroup.

Explanation: The specified application is not definedto this group.

System Action: Program continues.

User Response: None.

64 NetView Access Services Version 2 Messages

Page 77: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1299E � EMS1312E

EMS1299E The specified user is not assigned to this group.

Explanation: There are no applications defined to thisuser in this group.

System Action: Program continues.

User Response: None.

EMS1300E Your PF key settings are: CopyFrom begin= PF nn,CopyFrom end=PF nn.

Explanation: This is information about the copy keyswhen you start the copy function with the CF command.

System Action: Program continues.

User Response: Press ENTER to continue.

EMS1301E Your PF key setting is: CopyTo= PF nn.

Explanation: This is information about the copy keys,displayed when you enter the CT (copyto) command.

System Action: Program continues.

User Response: Press ENTER to continue.

EMS1302E You have already entered a CF command.

Explanation: The user entered the CF (copyfrom)command, but had already initiated the copy function.

System Action: Ignores the command.

User Response: Complete the previous copy functionbefore starting a new one.

EMS1303E You have already entered a CT command; now markthe spot to be copied to.

Explanation: The user entered the CT (copyto)command, but had already initiated the copyto function.

System Action: Ignores the command.

User Response: Define the target position for thecopyto sequence and press the valid key.

EMS1304E The copy function has not yet been started; enter CFcommand.

Explanation: You have entered the CT (copyto)command, but have not previously used the CFcommand. The sequence of commands has not beencorrectly followed.

System Action: Ignores the command.

User Response: First enter the CF command andfinish the copy function with the CT command.

EMS1305E The copy area is not yet completely defined; markarea xxxx.

Explanation: You have pressed an invalid key.

xxxx = begin or end.

System Action: Ignores the command.

User Response: Define the target position and pressthe valid key.

EMS1306E The copy function has not been started; the CQcommand is ignored.

Explanation: You have entered the CQ (copyquit)command, but have not started the copy function.There was therefore no need to use the CQ command.

System Action: Ignores the command.

User Response: None.

EMS1307E You cannot copy into a graphics screen; the copyfunction has been canceled.

Explanation: You tried to copy into a graphics screen.The copy function is canceled because it is not possibleto display the copied data.

System Action: The copy function terminates.

User Response: None.

EMS1308E A copy area now exists for application nnnnnnnn. Toproceed, use the CT command.

Explanation: The CopyFrom operation has been com-pleted successfully.

System Action: Program continues.

User Response: Perform the CopyTo operation.

EMS1309E The wrong CopyFrom-begin PF key was pressed; thecorrect key is PF nn.

Explanation: You pressed an invalid key.

System Action: Ignores the command.

User Response: Press the valid key to define thestarting position of the copy field.

EMS1310E The wrong CopyFrom-begin PF key was pressedagain; the copy function has been canceled.

Explanation: You entered the CF (copyfrom)command, but then twice pressed the wrong PF key tomark the beginning of the CopyFrom area.

System Action: The copy function is terminated.

User Response: Try again.

EMS1311D The wrong CopyFrom-end PF key was pressed; thecorrect key is PF nn.

Explanation: You pressed an invalid key.

System Action: Ignores the command.

User Response: Press the valid key to define the endposition of the copy field.

EMS1312E The wrong CopyFrom-end PF key was pressedagain; the copy function has been canceled.

Explanation: You pressed the correct CopyFrom-beginkey, but then twice pressed the wrong PF key to markthe end of the CopyFrom area.

System Action: The copy function is terminated.

User Response: Try again.

Chapter 2. Administrator and User Messages 65

Page 78: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1313D � EMS1324D

EMS1313D The option for Interruptive Message must be Y or N;enter one of these values.

Explanation: The administrator entered an invalidcharacter in the Interruptive Message field.

System Action: Program continues.

User Response: Enter correct value.

EMS1314E The copy function has been canceled due to aninternal error.

Explanation: The copy function was called with invalidparameters in the control block. This is an internalerror, and should be reported to system support. Thefunction is terminated and any copy buffers are freed.There is an operator console message associated withthis panel message.

System Action: Function terminated and NetViewAccess Services displays the Application Selectionpanel.

User Response: Try again and call your administrator.

EMS1315E Administration exit checking has rejected therequest.

Explanation: The installation-wide administration exitEMSEADEX detected an error while verifying theinstallation-wide administration exit data. No more spe-cific message was supplied by the exit.

System Action: The profile alteration is stopped.Message EMS0655E is issued to the console, showingthe exact reason, unless suppressed within the exit.

User Response: If the reason is not apparent thenrefer the matter to your systems support personnel.They should study the return code shown on theconsole and may change the exit to issue a more mean-ingful message. See also message EMS1398E.

EMS1316E The wrong CopyTo PF key was pressed; the correctkey is PF nn

Explanation: You entered the CT (copyto) command,but did not then press the correct PF key to mark thebeginning of the copyto area.

System Action: The copy function is terminated.

User Response: Ask your administrator for the correctcopy function PF keys.

EMS1317D The option for Time Controlled Message must be Y,N, or D; enter one of these values.

Explanation: The administrator entered an invalidcharacter in the Time Controlled Message field.

System Action: None.

User Response: Enter correct value.

EMS1318E The wrong CopyTo PF key was pressed again; thecopy function has been canceled.

Explanation: You entered the CT (copyto) command,but then twice pressed the wrong PF key to mark thebeginning of the CopyTo area.

System Action: The copy function is terminated.

User Response: Select a correct position for data tobe copied to, and reinitiate the copy function with the CF(copyfrom) command.

EMS1319E The copy function has been canceled due to anincorrect sequence of actions.

Explanation: You made two errors in sequence, whichcaused the cancelation.

System Action: The copy function is terminated.

User Response: Reinitiate the copy function with theCF (copyfrom) command.

EMS1320D The option for Purge Message must be Y or N; enterone of these values.

Explanation: The administrator entered an invalidcharacter in the Purge message field.

System Action: Program continues.

User Response: Enter correct value.

EMS1321E The copy function has been canceled by user.

Explanation: You entered the CQ command.

System Action: The copy function is canceled.

User Response: None.

EMS1322I There are no messages to be listed.

Explanation: The administrator entered the LISTcommand to list selective broadcast messages, butthere are either no messages defined or the adminis-trator entered a valid command in the broadcast listpanel and no messages are available (could be purgedby the timer).

System Action: Normal processing.

User Response: None.

EMS1323E Message table full; no new message ID available.

Explanation: The administrator entered the ADDcommand to add a broadcast message, but there is nofree message ID available.

System Action: Program continues.

User Response: Delete messages no longer needed.

EMS1324D Stop time equal to or less than start time.

Explanation: The administrator entered a stop time fora time-controlled message that is equal to or less thanthe start time.

System Action: Program continues.

User Response: Correct time entries.

66 NetView Access Services Version 2 Messages

Page 79: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1325E � EMS1337E

EMS1325E Open failure for member xxxxxxxx.

Explanation: The member specified on the EMSPS7panel could not be opened for read access.

System Action: Program continues.

User Response: Check member xxxxxxxx for correctparameters.

EMS1326 The option for Message Received Indication must beN, I, or J; enter one of these values.

Explanation: You have entered an invalid value in theMessage Received Indication field.

System Action: Program continues.

User Response: Enter a valid value.

EMS1327E I/O error occurred while reading member xxxxxxxx.

Explanation: The member specified on the EMSPS7panel could not be read.

System Action: Program continues.

User Response: See Operator Messages for furtherinformation.

EMS1328E FILEDEF failed for xxxxxx.

Explanation: The FILEDEF macro for the broadcastfile * EMSBRO has failed.

System Action: Program continues.

User Response: See further error description on oper-ator console.

EMS1329E Invalid LRECL detected in member xxxxxx.

Explanation: The record length of the specifiedmember is invalid.

System Action: Program continues.

User Response: Check the record length of themember against the description in NetView Access Ser-vices Version 2 Operation.

EMS1330E You are now logged off from the application.

Explanation: Logoff generation for the application wassuccessful.

System Action: NetView Access Services displays theApplication Selection panel.

User Response: None.

EMS1331E You are already logged off from the application.

Explanation: You attempted a logoff from an applica-tion with which there was no session.

System Action: Program continues.

User Response: None.

EMS1332E Error response from application. Reselect an appli-cation.

Explanation: During a logon or logoff generation, thefunction received an error response from the VTAMinterface when attempting to send data to the applica-tion. The last application panel is available for the userto display. There is an operator console message asso-ciated with this panel message.

System Action: The logon or logoff function iscanceled—NetView Access Services displays the Appli-cation Selection panel.

User Response: Continue to log on or log off manu-ally, if the application permits it.

EMS1333E Error response from terminal received for xxxxx.Logmode might be incorrect.

Explanation: An error was received during a Sendoperation. The data sent by the application cannot behandled by the terminal. Consequently, incorrectsession parameters might be used by the application.

System Action: The Application Selection Panel is dis-played.

User Response: Check if the BIND parameters usedfor this session are correct; for example, the logmodename might be incorrect. If a logmode has beenentered, check for the correct name. Retry selectionwithout entering the logmode.

EMS1334E Application data not available. Refresh the screen.

Explanation: An error was received during a sendoperation. The data sent by the application cannot behandled by the terminal. Consequently, incorrectsession parameters may be used by the application.

System Action: The session remains active.

User Response: Retry the application. If the problempersists, check if the BIND parameters used for thissession are correct; for example, the logmode namemight be incorrect. If a logmode has been entered,check for the correct name. Log off, and retry selectionwithout entering the logmode.

EMS1336E Member xxxxxxxx not found.

Explanation: The specified member could not befound in the PDS.

System Action: Program continues.

User Response: Check that the member name isspelled correctly. Check installation-dependent name.

EMS1337E Invalid generic terminal name.

Explanation: The specified terminal ID contains char-acters that are not alphanumeric. The asterisk is notthe last character of the string.

System Action: Program continues.

User Response: Check that the terminal ID is spelledcorrectly.

Chapter 2. Administrator and User Messages 67

Page 80: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1338E � EMS1347E

EMS1338E Syntax error in time entry.

Explanation: The time field where the cursor is placedcontains either non-numeric characters, or the hours arenot in the range 0-24, or the minutes are not in therange 0-59.

System Action: Program continues.

User Response: Correct time entry.

EMS1339E Syntax error in date entry.

Explanation: The date field where the cursor is placedcontains non-numeric characters.

System Action: Program continues.

User Response: Correct date entry.

EMS1340E Logoff sequence recorded for aaaaaa. Enter FR tofile or QR to quit recording.

Explanation: Logoff recording has ended because youhave been logged off from the application.

System Action: Terminate the BR command, but keepthe recording.

User Response: Use the FR command to file therecording, or the QR command to quit as desired.

EMS1341E BRA function not possible, maximum number ofalternative sequences exceeded.

Explanation: The limit of alternative sequences speci-fied by the system administrator for this application hasbeen exceeded. Therefore, no more alternativerecordings can be made.

System Action: Logon recording does not start.NetView Access Services displays the ApplicationSelection panel.

User Response: No more alternative recordings arepossible. Ask the system administrator whether the limitcan be increased.

EMS1342E Recording function canceled; application nnnnnnnncould not be allocated.

Explanation: Logon not possible, so the recordingfunction was not started. An operator console messageis associated with this panel message.

System Action: Logon recording does not start.NetView Access Services displays the ApplicationSelection panel.

User Response: The application might not be active inthe system, try later.

EMS1343E BR function canceled; unexpected input from theuser.

Explanation: The recording function was interruptedby an unexpected message stream. You entered datawhen the function expected data from the application.The function is terminated at the point reached so far.You may be entering new data from the keyboard,without first waiting for a reply from the application. TheBR command function expects a one-for-one entry/reply

sequence, and therefore you should be careful to recorda clean sequence.

System Action: Logon or logoff recording terminates.NetView Access Services displays the ApplicationSelection panel.

User Response: Record the sequence again.

EMS1344E BR canceled; unexpected message from applicationnnnnnnnn.

Explanation: The recording function was interruptedby an unexpected message stream. A message wasreceived from the application when a user response wasexpected. The function is terminated at the pointreached so far. There is an operator console messageassociated with this panel message.

System Action: Logon or logoff recording terminates.NetView Access Services displays the ApplicationSelection panel.

User Response: Try the recording again.

EMS1345E BR function canceled due to internal error.

Explanation: The recording function was called withinvalid parameters. The function is terminated and anyrecording freed. There is an operator console messageassociated with this panel message.

System Action: Logon or logoff recording terminates.NetView Access Services displays the ApplicationSelection panel.

User Response: Try the recording again.

EMS1346E BR function canceled due to insufficient storage;inform your administrator and try later.

Explanation: A GETMAIN request could not be satis-fied, so the recording function was either not started, orwas terminated and the recording freed. There is anoperator console message associated with this panelmessage.

System Action: Logon or logoff recording terminates.NetView Access Services displays the ApplicationSelection panel.

User Response: Inform the system administrator, andtry the recording again.

EMS1347E BR function terminated. Unsupported data streamdetected by automatic logon/logoff.

Explanation: The installation-wide exit routine calledby NetView Access Services to analyze a data streamand return a panel ID gave a return code other than 0.There is an operator console message associated withthis panel message.

System Action: Logon or logoff recording terminates.NetView Access Services displays the ApplicationSelection panel.

User Response: Inform the system administrator andtry the recording again.

68 NetView Access Services Version 2 Messages

Page 81: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1348E � EMS1363E

EMS1348E The specified message is not defined in the system.

Explanation: The administrator entered a DISPLAY,UPDATE, or DELETE command with a message or lan-guage ID that is not known to the system.

System Action: Program continues.

User Response: Check message and language ID.Use LIST function.

EMS1349E The specified message already exists.

Explanation: The administrator entered an ADDcommand with a message or language ID that alreadyexists.

System Action: Program continues.

User Response: Check message and language ID.Use LIST function.

EMS1352E Automatic logon/logoff terminated; reselect applica-tion.

Explanation: The logon or logoff process has beeninterrupted prematurely due to an error.

System Action: Terminates the function and displaysthe message on the Application Selection panel.

User Response: Reselect application and continue.

EMS1353E You are not authorized to use automatic logon/logofffor this application.

Explanation: Logon and logoff must be carried outmanually.

System Action: Terminates the function and displaysthe message on the Application Selection panel.

User Response: Ask the system administrator forautomatic logon authorization, or log on or log off manu-ally.

EMS1354E Automatic logon and logoff not possible for pass-mode applications.

Explanation: It is not possible to record a logon orlogoff sequence for a pass-mode application.

System Action: Terminates the function and displaysthe message on the Application Selection panel.

User Response: None.

EMS1356D Message text is empty.

Explanation: The administrator entered an ADD orUPDATE command, but left the message text empty.

System Action: Program continues.

User Response: Enter message text.

EMS1357D Input field conflicts with existing message text. EnterDISPLAY or press CLEAR key.

Explanation: You pressed the ENTER key withoutspecifying a command. There is a command conflictbecause the text of a broadcast message is alreadyspecified in the background.

System Action: Program continues.

User Response: Enter an explicit command, or press

the CLEAR key to refresh the panel (including text in thebackground).

EMS1358I Caution; Message not found on disk.

Explanation: You entered an UPDATE command for atime-controlled message. This message was not foundin the VSAM data set.

System Action: Program continues.

User Response: For further information look at theVSAM return code on the console.

EMS1359D The option for Data Compression must be Y, N, or F;enter one of these values.

Explanation: Y must be specified if outbound-onlycompression is required. If inbound and outbound com-pression is required (only possible if Y specified forVirtual Terminal), F must be specified.

System Action: The appropriate command was notexecuted. NetView Access Services continues.

User Response: Correct your input.

EMS1360D Specify a group ID or name.

Explanation: You have entered the GLF commandwithout specifying the group.

System Action: Program continues.

User Response: Correct your input.

EMS1361E You are not authorized to record a logon or logoffsequence for this application.

Explanation: You are not authorized to record a logonor logoff sequence. Logon and logoff must be carriedout manually.

System Action: Terminates the function and displaysthe message on the Application Selection panel.

User Response: Ask the administrator for recordauthorization, or log on or log off manually.

EMS1362E DDNAME not found.

Explanation: The startup job does not contain a DDstatement for the broadcast-partitioned data set.

System Action: The appropriate command was notexecuted. Program continues.

User Response: None.

EMS1363E Recording already in progress for applicationaaaaaaaa.

Explanation: 1) You have already used the BRcommand to create a temporary recording, but have notused the FR or QR command to further process it.2) You have already used the AG or AS command onanother terminal, but the process has not yet ended.

System Action: Display message on the ApplicationSelection panel.

User Response: 1) Use the FR or QR command asdesired, and try again.2) Use the AG or AS command as desired, and tryagain.

Chapter 2. Administrator and User Messages 69

Page 82: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1364E � EMS1375E

EMS1364E The specified group is not known.

Explanation: You have selected a group that is notknown.

System Action: Program continues.

User Response: Select another group.

EMS1365E No recording in progress for application aaaaaaaa.

Explanation: You have used the QR or FR commandto quit or file a recording, but you do not have one inexistence. You may have used the BR command, buthave not actually recorded any steps of a logon or logoffsequence or, alternatively, the recording was previouslyterminated by an error.

System Action: Display message on the ApplicationSelection panel.

User Response: Use the BR command to create arecording, if required.

EMS1366E Recording for application aaaaaaaa canceled.

Explanation: You have used the QR command to quita recording.

System Action: Display message on the ApplicationSelection panel.

User Response: None.

EMS1367A Reenter QR command to confirm request.

Explanation: You must repeat the QR command todelete the recording.

System Action: Display message on the ApplicationSelection panel.

User Response: Repeat the command if you wish toquit recording, otherwise the recording will be kept forfiling.

EMS1368A No main recording exists for profile.

Explanation: You have recorded an alternative logonsequence, but there is no main sequence recorded forthe application.

System Action: Display message on the ApplicationSelection panel.

User Response: Use an alternative form of the FRcommand, FRI or FRM.

EMS1369E Recording for application aaaaaaaa filed in logonprofile y. Recorded steps nn.

Explanation: You have used the FR command suc-cessfully.

aaaaaaaa = application namey = 1 or 2.

System Action: Display message on the ApplicationSelection panel.

User Response: None.

EMS1370I You are now logged off from all applications inpublic group nnnnnnnn.

Explanation: Logoff from all applications within publicgroup nnnnnnnn was successful.

System Action: Program continues.

User Response: None.

EMS1371I Your session with nnnnnnnn was interrupted byinterruptive messages from aaaaaaaa. Indicationmode is ‘I’.

Explanation: You have received messages from anapplication with indication mode ‘I’.

System Action: Program continues.

User Response: None.

EMS1372I Your session with nnnnnnnn was interrupted byinterruptive messages from several applications. Atleast one has indication ‘J’.

Explanation: You have received messages fromseveral applications. One of them has indication mode‘J’. A jump is not processed, because there are morethan one interruptive applications with stored messages.

System Action: Program continues.

User Response: None.

EMS1373I Your session with nnnnnnnn was interrupted byinterruptive messages from several applications.

Explanation: You have received messages fromseveral applications with indication mode ‘I’.

System Action: Program continues.

User Response: None.

EMS1374E VSAM error occurred during processing of ALLTrecords.

Explanation: An error occurred writing ALLT VSAMrecords. An operator console message is associatedwith this panel message.

System Action: Function terminates. NetView AccessServices displays the Application Selection panel.

User Response: Contact the operator.

EMS1375E An identical logon sequence exists; no alternativerecording filed.

Explanation: You have entered the BRA command,and recorded a logon or logoff sequence that is identicalto one already recorded as a main or an alternativesequence for the profile.

System Action: Delete the temporary recording.

User Response: You can try with a differentsequence.

70 NetView Access Services Version 2 Messages

Page 83: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1376E � EMS1388E

EMS1376E You cannot use the BRA command to record a logoffsequence.

Explanation: You can only create and store a mainsequence for logoff. No alternative sequences are pos-sible for a logoff.

System Action: Program continues.

User Response: Use the BR command to create anew temporary sequence if desired, and file it using theFR command.

EMS1377I Broadcast message wrap-around has occurred.

Explanation: All Broadcast messages have beenseen. The Broadcast message pool for you haswrapped around.

System Action: Program continues.

User Response: None.

EMS1378E Message ID is already in use; try another one.

Explanation: The system has simultaneously gener-ated an MSLID that is used by another administrator.

System Action: Program continues.

User Response: Change or delete MSLID and tryagain.

EMS1379I Stop time elapsed and purge = Y is an invalid spec-ification.

Explanation: You have entered a time-controlledmessage with an elapsed time, and a purge value ofyes. This message is rejected as it would immediatelybe deleted.

System Action: Program continues.

User Response: Correct time input field specifications.

EMS1380E You are not authorized to use the AG command forthis group.

Explanation: You are not an administrator for thegroup, and therefore cannot use the activate grouprecording command.

System Action: Program continues.

User Response: See the group administrator if thereis one, and ask him to make and activate a recording,use your own profile (by changing Logon Profile to U),or have yourself authorized as an administrator for thegroup.

EMS1381E You are not authorized to use the AS command.

Explanation: You are not a system administrator, andtherefore cannot use the activate system recordingcommand.

System Action: None.

User Response: See the system administrator if thereis one, and ask him to make and activate a recording,use your own profile (by changing Logon Profile to U for

user or G for group), or have yourself authorized as asystem administrator.

EMS1382E No active logon/logoff profile exists for applicationyyyyyyyy.

Explanation: You have not recorded a logonsequence, or have not activated a recording (bychanging Logon Profile to U for user, or G for Group,and the active profile to 1 or 2 as appropriate), or nogroup or system profile exists for that application.

System Action: The recording function terminates. Ifyou have entered the TR command for an activesession, the session is terminated.

User Response: Use the BR command to create aprofile, or ask the group or system administrator tocreate and activate a profile, and continue with theapplication manually.

EMS1383E Your active logon profile must be 1 or 2.

Explanation: The active logon profile for the applica-tion for the administrator must be 1 or 2 beforeattempting the AG or AS command.

System Action: Program continues.

User Response: Change the logon profile to 1 or 2 asdesired.

EMS1384E Group recording filed for application yyyyyyyy.

Explanation: The administrator has successfully usedthe AG command to activate a logon for the applicationfor his group.

System Action: Program continues.

User Response: None.

EMS1385E System recording filed for application yyyyyyyy.

Explanation: The administrator has successfully usedthe AS command to activate a logon profile for the appli-cation at the system level.

System Action: Program continues.

User Response: None.

EMS1387E Terminal is currently not available for assume.

Explanation: You are trying to assume a session froma terminal that is currently processing a NetView AccessServices function (for example, reading a terminalbuffer).

System Action: Program continues.

User Response: Try again later.

EMS1388E Copy canceled due to selection of pass mode.

Explanation: You have selected a pass-mode applica-tion as the target for a copy operation. The copy func-tion is not possible with pass-mode applications.

System Action: The copy function is terminated.

User Response: None.

Chapter 2. Administrator and User Messages 71

Page 84: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1389E � EMS1408E

EMS1389E Terminal assume not allowed during automaticlogon/logoff processing.

Explanation: You are trying to assume a terminal thatis currently processing an automatic logon/logoff.

System Action: Program continues.

User Response: The assume can be attempted againonce the automatic logon/logoff process has completedat the original terminal.

EMS1390E The Language ID must be a number between 1 and8.

Explanation: An incorrect value has been entered oneither the Language Selection panel or the Broadcast aMessage panel to select a language.

System Action: Program continues.

User Response: Enter a number between 1 and 8 toselect a language.

EMS1391E This Language ID is currently not in use.

Explanation: There is no language defined for this lan-guage ID.

System Action: Program continues.

User Response: Enter the correct number for the lan-guage of your choice.

EMS1392E There is no Broadcast Message for Language ID lllll.

Explanation: There is no Broadcast Message for theselected language. The language selected is identifiedby lllll.

System Action: Program continues.

User Response: None.

EMS1393E You must enter a Broadcast Message.

Explanation: You want to add a broadcast messagefor a valid language ID, but there is no input in theBroadcast Message field.

System Action: Program continues.

User Response: Enter a broadcast message.

EMS1395E You cannot update Language ID lllll. Only an existingBroadcast Message can be updated.

Explanation: You want to update a broadcastmessage for a valid language ID, but no broadcastmessage for that language exists. The language isidentified by lllll.

System Action: Program continues.

User Response: Add a broadcast message for thelanguage ID.

EMS1396E You cannot add a message for Language ID lllll. AnADD is only possible when there is no active Broad-cast Message for an ID.

Explanation: You want to add a broadcast messagefor a valid language ID, but there is already a broadcastmessage for that language ID.

System Action: Program continues.

User Response: Update the active broadcastmessage.

EMS1397E You can cccccc only active Broadcast Messages.

Explanation: You want to cccccc a broadcastmessage, but no language ID for the chosen languageexists. cccccc is either UPDATE or DELETE.

System Action: Program continues.

User Response: Update or delete an active broadcastmessage.

EMS1398E xxxxx xxxxx xxxxx xxxxx.

Explanation: This message number is used to displayany text supplied from the administration exitEMSEADEX. The actual text varies from installation toinstallation.

System Action: The profile alteration may have com-pleted depending on the command being processed.Message EMS0655E may also be issued to the console.

User Response: If the reason is not apparent, consultyour system programmer.

EMS1399E Unknown message number specified in panel defi-nition.

Explanation: An unknown or invalid message numberwas specified in the panel definition of the panel onwhich this message has been displayed.

System Action: Program continues.

User Response: Verify the message numbers on thefailing panel. Check if the number specified in the paneldefinition is correctly defined in the message table.Correct the message or message number.

EMS1407E The content of the selected item is displayed. SelectPF-keys.

Explanation: You have selected a Bulletin Board item,and the content of that item is displayed.

System Action: Program continues.

User Response: None.

EMS1408E There are no Bulletin Board items available.

Explanation: You have requested to view BulletinBoard items, but no items are available.

System Action: Program continues.

User Response: None.

72 NetView Access Services Version 2 Messages

Page 85: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1409E � EMS1621E

EMS1409E This item is not selectable. Contact your operator.

Explanation: You have selected an item whosecontent is not available or whose content uses too muchspace to display.

System Action: Program continues.

User Response: Contact operator.

EMS1413E Cursor select is only valid on index panels.

Explanation: You have pressed ENTER, but no indexmember was on screen.

System Action: Program continues.

User Response: Press a valid key.

EMS1414E You are at the top of this board.

Explanation: You have pressed the Top PF-key asecond time, but the top of the Bulletin Board has beenreached.

System Action: Program continues.

User Response: Press the correct key.

EMS1415E You are at the bottom of this board.

Explanation: The user has pressed the Bottom PF-keya second time, but the bottom of the Bulletin Board hasbeen reached.

System Action: Program continues.

User Response: Press the correct key.

EMS1416E The cursor must be positioned on an item line beforeyou press the ENTER key.

Explanation: You pressed ENTER when the cursorwas not positioned on a Bulletin Board item.

System Action: The action is rejected and the BulletinBoard panel is redisplayed. Program continues.

User Response: Position the cursor on a BulletinBoard item and press ENTER.

EMS1531E The specified TPN is not a character string.

Explanation: You have entered an ASR name that isnot a one-character string, or that is not allowed with thespecified ACB type.

System Action: Program continues.

User Response: Correct your input.

EMS1532E Primary LU name must be blank for ACB type N.

Explanation: The primary logic unit name forASR-to-ASR communication must be blank.

System Action: Program continues.

User Response: Correct your input.

EMS1533E Access Type must be Relay.

Explanation: You can only use relay mode forASR-to-ASR communication.

System Action: Program continues.

User Response: Correct your input.

EMS1534E For ACB Type = N TPN has to be specified.

Explanation: A transaction program name must bespecified for ACB Type=N.

System Action: Program continues.

User Response: Correct your input.

EMS1535E Pseudo Terminal Prefix must be blank for ACB TypeN.

Explanation: The Pseudo Terminal Prefix must beblank for ASR-to-ASR communication.

System Action: Program continues.

User Response: Correct your input.

EMS1536E ACB Type has to be N if TPN is specified.

Explanation: If you specify a TPN, the ACB Type mustbe N.

System Action: Program continues.

User Response: Correct your input.

EMS1537E Backup Application Name must be blank for ACBType N.

Explanation: You have entered the name of a backupapplication for ASR-to-ASR communication, but abackup ASR cannot be specified for an ASR.

System Action: Program continues.

User Response: Enter blanks for the backup applica-tion name.

EMS1538E The specified Backup Application Name is not valid.

Explanation: Either the backup application is notdefined to NetView Access Services or you haveentered the name incorrectly.

System Action: Program continues.

User Response: Correct your input.

EMS1586E The Status Update interval must be between 0 and1440.

Explanation: You have entered an invalid value for thestatus update interval.

System Action: Program continues.

User Response: Correct your input.

EMS1588E The Status Update interval must be 0 for ACB TypeN.

Explanation: The status update interval must be 0 ifyou specify ACB type N.

System Action: Program continues.

User Response: Correct your input.

EMS1621E Printer pppppppp is busy; try later. Press PF3 toleave this panel.

Explanation: The requested printer pppppppp is busy.

System Action: Program continues.

User Response: Try again later.

Chapter 2. Administrator and User Messages 73

Page 86: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1622E � EMS1634E

EMS1622E You cannot specify this application as your defaultapplication.

Explanation: You have tried to specify the application(eight dots, free selection) as your default application.However, it cannot be specified as the default applica-tion.

System Action: Program continues.

User Response: None.

EMS1623E Session not established. Reason: You are notallowed to share this application.

Explanation: The NetView Access Services adminis-trator has not authorized you to share this application.

System Action: Program continues.

User Response: Contact your NetView Access Ser-vices administrator.

EMS1624E Session not established. Reason: Requested user isnot allowed to share sessions.

Explanation: The NetView Access Services adminis-trator has not authorized the user to share sessions.

System Action: Program continues.

User Response: Contact your NetView Access Ser-vices administrator.

EMS1625E Session not established. Reason: Requested user isnot allowed to share sessions with your group.

Explanation: The NetView Access Services adminis-trator has not authorized your group to share an applica-tion with users of another group.

System Action: Program continues.

User Response: Contact your NetView Access Ser-vices administrator.

EMS1626E Session not established. Reason: Terminal types arenot matching.

Explanation: The terminal types of both partners of ashared session must be the same.

System Action: Program continues.

User Response: Check the terminal types and try tofind terminals of the same types.

EMS1627E Session not established. Reason: Requested user isin a pass mode session.

Explanation: You cannot share a session with apartner who has a pass mode session.

System Action: Program continues.

User Response: Contact your session partner.

EMS1628E Session not established. Reason: It is not possibleto establish a shared session when in copy, record,or logon mode.

Explanation: Both session partners must not be incopy, record, or logon mode for this session.

System Action: Program continues.

User Response: Leave the appropriate mode.

EMS1629E Session not established. Reason: Your partner isalready sharing a session.

Explanation: Your partner is already sharing asession.

System Action: Program continues.

User Response: Contact your session partner.

EMS1630E Session not established. Reason: The selected appli-cation cannot be shared.

Explanation: The NetView Access Services adminis-trator has specified that this application cannot beshared.

System Action: Program continues.

User Response: Contact your NetView Access Ser-vices administrator.

EMS1631E Session not established. Reason: Your group is notallowed to share sessions with this application.

Explanation: The NetView Access Services adminis-trator has specified that your group cannot share ses-sions with applications.

System Action: Program continues.

User Response: Contact your NetView Access Ser-vices administrator.

EMS1632E Wrong password entered. Fill in the password andpress ENTER to share session. Commands can onlybe entered by you.

Explanation: You have entered the wrong password.

System Action: Program continues.

User Response: Enter the correct password and pressENTER.

EMS1633E Session not established. Reason: No user ID speci-fied.

Explanation: You did not specify a user ID on theShared Session Request panel.

System Action: Program continues.

User Response: Specify the user ID.

EMS1634E Session not established. Reason: Requested usernot found.

Explanation: The parameters you entered on theShared Session Request panel did not specify a user, orthe partner is not logged on.

System Action: Program continues.

User Response: Check all the entered parametersand check that the user is logged on.

74 NetView Access Services Version 2 Messages

Page 87: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1635E � EMS1648E

EMS1635E Session not established. Reason: User ID is ambig-uous. Specify group ID as well.

Explanation: The user ID you entered on the SharedSession Request panel is ambiguous as the user isassigned to use applications in more than one group.Specify the requested partner with more details.

System Action: Program continues.

User Response: Specify group ID to define therequested partner exactly.

EMS1636E Session not established. Reason: Session partner isactive on several terminals. Specify terminal ID.

Explanation: The requested partner is active onseveral terminals. Specify the requested partner withmore details.

System Action: Program continues.

User Response: Specify terminal ID to define therequested user exactly.

EMS1637E Session not established. Reason: The applicationname is not specified.

Explanation: You did not specify an application namewhen issuing the share command or did not enter aname on the Shared Session Request panel.

System Action: Program continues.

User Response: Specify the application name.

EMS1638E Session not established. Reason: Shared mode isnot specified.

Explanation: You did not specify the share mode onthe Shared Session Request panel.

System Action: Program continues.

User Response: Specify the Share Mode.

EMS1639E Session not established. Reason: Invalid SharedMode specified.

Explanation: You specified a share mode other than F(Forward), or S (Share) on the Shared Session Requestpanel.

System Action: Program continues.

User Response: Enter the correct value.

EMS1640E Session not established. Reason: Selected applica-tion not found.

Explanation: The application you selected on theShared Session Request panel was not found.

System Action: Program continues.

User Response: Check the given application.

EMS1641I Session not established. Reason: Internal erroroccurred.

Explanation: An internal error has occurred. Themodule detecting this error issues a message to theoperator console that describes the error in more detail.

System Action: Depending on the error, processingeither continues or the function is canceled.

User Response: Contact the operator for details.

EMS1642I Session not established. Reason: Application is notavailable.

Explanation: The application you selected is no longeravailable for this session.

System Action: Program continues.

User Response: Contact the operator for details.

EMS1643E Session not established. Reason: The specifiedapplication is not known.

Explanation: The specified application ID or name wasnot found.

System Action: Program continues.

User Response: Check the application ID or nameand try again.

EMS1644E Default printer name saved.

Explanation: The name of the printer selected as thedefault printer has been saved in the user profile.

System Action: Program continues.

User Response: None.

EMS1645E Missing name in panel field for the selected printer.

Explanation: You have pressed ENTER to send acopy of a panel to a printer but the printer name ismissing.

System Action: Program continues.

User Response: Select another printer or enter aprinter name in the User Defined Printer field.

EMS1646E Error occurred on printer pppppppp. The printer isdeallocated.

Explanation: An error has occurred on the specifiedprinter.

System Action: Program continues.

User Response: None.

EMS1647E Panel copy to printer pppppppp initiated. Press PF3to exit from this panel.

Explanation: The copy of the panel was successfullysent to the specified printer.

System Action: Program continues.

User Response: Press PF3 to exit from the panel.

EMS1648E Panel copy to printer pppppppp canceled.

Explanation: You canceled the print request whileNetView Access Services was waiting for completion ofprinter allocation.

System Action: Program continues.

User Response: Start another print request or pressPF3 to exit from the panel.

Chapter 2. Administrator and User Messages 75

Page 88: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1649E � EMS1683E

EMS1649E You cannot store the printer value permanently whenyou are defined to a public group. The value isstored temporarily during this session.

Explanation: You cannot store the printer valuebecause you are defined to a public group.

System Action: Program continues.

User Response: None.

EMS1650D The value for shareable must be Y or N; enter one ofthese values.

Explanation: You have entered a value that is notcorrect.

System Action: Program continues.

User Response: Correct your input.

EMS1651E Applications are only shareable in relay mode.

Explanation: You have specified an access modevalue other than relay and the value Y for shareable onthe Define an Application to this System panel.

System Action: Program continues.

User Response: Correct your input.

EMS1652D The specified value for shared session response isnot valid; enter S, G, or N.

Explanation: You have entered a value other than S,G, or N on the Define a Group panel.

System Action: Program continues.

User Response: Correct your input.

EMS1664E Wrong password entered. Fill in the password andpress ENTER to share session. Commands can onlybe entered by your partner.

Explanation: You have entered the wrong password.

System Action: Program continues.

User Response: Enter the correct password and pressENTER.

EMS1676E The option for Application ID Display must be Y or N.

Explanation: The syntax of the entered value is notcorrect.

System Action: The appropriate command was notexecuted. Program continues.

User Response: Correct your input.

EMS1677E The row value for the Application ID Display must bein the range of -43 to 43 except the value zero.

Explanation: The entered row value is not correct.

System Action: The appropriate command was notexecuted. Program continues.

User Response: Correct your input.

EMS1678E The column value for the Application ID Displaymust be in the range of -132 to 132 except the valuezero.

Explanation: The entered column value is not correct.

System Action: The appropriate command was notexecuted. Program continues.

User Response: Correct your input.

EMS1679E The color must be R, G, B, W, Y, T, P or blank.

Explanation: You entered an incorrect value. Validvalues are R (Red), G (Green), B (Blue), W (White), Y(Yellow), T (Turquoise), P (Pink) or the field can be leftblank.

System Action: The appropriate command was notexecuted. Program continues.

User Response: Correct your input.

EMS1680E The highlighting must be H, R, B, U, or blank.

Explanation: You entered an incorrect value. Validvalues are H (Highlight), R (Reverse Video), B(Blinking), U (Underscore), or the field can be left blank.

System Action: The appropriate command was notexecuted. Program continues.

User Response: Correct your input.

EMS1681E You cannot specify the Application ID Display forthis application.

Explanation: Your group administrator has specifiedthat the identifier is to be suppressed for this application.

System Action: Your definition for the application ID ofthis application is not stored in your profile. Programcontinues.

User Response: Call your group administrator and askhim for the reason of the ID being suppressed.

EMS1682E Your installed security exit does not allow thisrequest.

Explanation: You tried to customize the installation-wide administration exit EMSEADEX, but the exit doesnot allow your request. For further information, refer toreturn code in related operator message EMS0655E.

System Action: The request is rejected.

User Response: Add or delete user or group as aRACF administrator using RACF commands.

EMS1683E First delete all users in this group.

Explanation: You tried to delete an external group, butthere are still users defined to the group.

System Action: The request is rejected.

User Response: Delete all users defined to the group,including the group administrator, and try again. Usethe RACF LIST command to list user IDs, if required.

76 NetView Access Services Version 2 Messages

Page 89: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1684E � EMS1733E

EMS1684E Administration Exit Data is only valid for externalgroups.

Explanation: You tried to process user-exit data for agroup other than external. NetView Access Servicesstores this data in RACF for external groups only. Datafor other group types is not stored in RACF.

System Action: The request is rejected.

User Response: Leave the user-exit data field blankor specify group type E.

EMS1685E Group type must not be changed.

Explanation: You tried to update the group type, butgroup data is stored in different databases.

System Action: The request is rejected.

User Response: None.

EMS1687E You cannot specify an Application ID display for afree selection application.

Explanation: You tried to specify an Application IDdisplay for a free selection application, but this is notallowed.

System Action: The request is rejected.

User Response: None.

EMS1719E The refresh facility has failed in modulemmmmmmmm RC = rr.

Explanation: An error was detected during refresh.

System Action: The refresh function is terminated.

User Response: Contact your operator for more infor-mation.

EMS1720D The profile database is in use; try again later.

Explanation: You tried to gain access to a VSAM dataset, but an ADD, UPDATE, REFRESH, or DELETEprocess is currently active.

System Action: Program continues.

User Response: Try the operation later.

EMS1722I The refresh facility has completed successfully.

Explanation: The VSAM data set (SRTS, SRTG,GPRF, and PLDT) has been loaded successfully intothe incore NetView Access Services profiles.

System Action: Program continues.

User Response: None.

EMS1723I A refresh is already being processed.

Explanation: A refresh request has already beenissued, so any new requests are ignored.

System Action: Program continues.

User Response: Try again later.

EMS1730E Automatic user logon in progress - Step nnn.

Explanation: You have selected an application forwhich you have automatic logon authorization and aprofile exists. nnn is the step number of the logonprocess.

System Action: Automatic logon is being performed.

User Response: Wait until the logon process is com-plete, when you are presented with the last applicationpanel in sequence. You can, however, interrupt theprocess by pressing CLEAR, and the last panel sent bythe application at that stage in the automatic logonprocess is displayed. You can then continue workingwith the application.

EMS1731E Automatic group logon in progress - Step nnn.

Explanation: You have selected an application forwhich you have automatic logon authorization and agroup profile exists. nnn is the step number of thelogon process.

System Action: Automatic logon is being performed.

User Response: Wait until the logon process is com-plete, when you are presented with the last applicationpanel in sequence. You can, however, interrupt theprocess by pressing CLEAR, and the last panel sent bythe application at that stage in the automatic logonprocess is displayed. You can then continue workingwith the application.

EMS1732E Automatic system logon in progress - Step nnn.

Explanation: You have selected an application forwhich you have automatic logon authorization and asystem profile exists. nnn is the step number of thelogon process.

System Action: Automatic logon is being performed.

User Response: Wait until the logon process is com-plete, when you are presented with the last applicationpanel in sequence. You can, however, interrupt theprocess by pressing CLEAR, and the last panel sent bythe application at that stage in the automatic logonprocess is displayed. You can then continue workingwith the application.

EMS1733E Automatic user logoff in progress - Step nnn.

Explanation: You have entered logoff for an applica-tion for which a user logoff sequence exists. nnn is thestep number of the logoff process.

System Action: Automatic logoff is being performed.

User Response: Wait until the logoff process is com-plete. You are then presented with messageEMS1350E (You are now logged off) on the ApplicationSelection panel. You can interrupt the process bypressing the CLEAR key. The session is then imme-diately deallocated.

Chapter 2. Administrator and User Messages 77

Page 90: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS1734E � EMS1742I

EMS1734E Automatic group logoff in progress - Step nnn.

Explanation: You have entered logoff for an applica-tion for which a group logoff sequence exists. nnn isthe step number of the logoff process.

System Action: Automatic logoff is being performed.

User Response: Wait until the logoff process is com-plete. You are then presented with messageEMS1350E (You are now logged off) on the ApplicationSelection panel. You can interrupt the process bypressing the CLEAR key. The session is then imme-diately deallocated.

EMS1735E Automatic system logoff in progress - Step nnn.

Explanation: You have entered logoff for an applica-tion for which a system logoff sequence exists. nnn isthe step number of the logoff process.

System Action: Automatic logoff is being performed.

User Response: Wait until the logoff process is com-plete. You are then presented with messageEMS1350E (You are now logged off) on the ApplicationSelection panel. You can interrupt the process bypressing the CLEAR key. The session is then imme-diately deallocated.

| EMS1737D The ASP format must be N or C; enter one of these| values.

| Explanation: You have entered an invalid value for the| ASP format parameter.

| System Action: None.

| User Response: Enter a correct value.

| EMS1739D Invalid Logmode name.

| Explanation: You have entered an invalid value for the| Logmode name.

| System Action: None.

| User Response: Enter a correct value.

| EMS1741E Invalid action for an External group.

| Explanation: You have entered an invalid action.

| System Action: None.

| User Response: Enter a correct value.

| EMS1742I Some authorized applications could not be shown| because limit of 99 applications has been reached.

| Explanation: Only the first 99 applications for the user| are displayed.

| System Action: None.

| User Response: None.

78 NetView Access Services Version 2 Messages

Page 91: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS5002I � EMS5011E

Chapter 3. Batch Load Messages

EMS5002I Unknown group name for SRTG record gggggggg,aaaaaaaa.

Explanation: During the consistency check of theNetView Access Services database, a group_applicationprofile was found with no corresponding group profile.

gggggggg = Group_nameaaaaaaaa = Application_name.

System Action: Program continues.

User Response: Define the corresponding groupprofile or delete the group_application profile.

EMS5003I Unknown system application ssssssss for SRTGrecord gggggggg, aaaaaaaa.

Explanation: During the consistency check of theNetView Access Services database, a group_applicationprofile was found with no correspondingsystem_application profile.

ssssssss = System_internal_namegggggggg = Group_nameaaaaaaaa = Application_name.

System Action: Program continues.

User Response: Define the correspondingsystem_application profile or delete thegroup_application profile.

EMS5004I No SRTG record found for SRTU record uuuuuuuu,gggggggg, aaaaaaaa.

Explanation: During the consistency check of theNetView Access Services database, a user profile wasfound with no corresponding group_application profile.

uuuuuuuu = User_IDgggggggg = Group_nameaaaaaaaa = Application_name.

System Action: Program continues.

User Response: Define the correspondinggroup_application profile or delete this user profile.

EMS5005I No SRTU record found for ALLT record uuuuuuuu,gggggggg, aaaaaaaa.

Explanation: During the consistency check of theNetView Access Services database an ALLT record wasfound with no corresponding user profile.

uuuuuuuu = User_IDgggggggg = Group_nameaaaaaaaa = Application_name.

System Action: Program continues.

User Response: Define the corresponding user profileor delete this ALLT profile record.

EMS5006I During the verification phase EMSEADEX hasaccepted all requests, but during the executionphase some of the requests were rejected byEMSEADEX.

Explanation: In CONDITIONAL operating mode theNetView Access Services Batch Load utility verifies allcommands in a first step. During this step theEMSEADEX is called for some profiles with thecommand VERDATA. Because the verification for allcommands was successful and EMSEADEX hasaccepted all requests the utility decided to enter theexecution phase. Now EMSEADEX is called for someprofiles to validate the execution for the respective com-mands. Some of the commands were rejected byEMSEADEX.

Note: The calls to EMSEADEX in the execution phaseare issued after updating the corresponding profiles inthe NetView Access Services database. Therefore theprofile updates are executed anyway, and it may still benecessary to perform the RACF updates via TSO.

System Action: Program continues.

User Response: Restore the previous characteristicsin the affected profiles or perform the RACF updates viaTSO.

EMS5009E Error in data set dddddddd. Return code = rrrrr.Reason code = sssss.

Explanation: An I/O error occurred while using OPEN,GET, or PUT, on the respective data set.

dddddddd = DD name of data setrrrr = Return codessss = Reason code.

System Action: Processing is terminated.

User Response: Check whether the respective dataset is correctly defined in the respective DD statementand is correctly allocated.

EMS5010E Record length of data set dddddddd must be lll.

Explanation: The data set was allocated with an incor-rect record length.

dddddddd = DD name of data setlll = Record length.

System Action: Processing is terminated.

User Response: Allocate the respective data set withthe correct record length.

EMS5011E Record format of data set dddddddd must be F or FB.

Explanation: The data set was allocated with an incor-rect record format.

dddddddd = DD name of data set.

System Action: Processing is terminated.

User Response: Allocate the respective data set withthe correct record format.

Copyright IBM Corp. 1987, 1997 79

Page 92: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS5012E � EMS5022I

EMS5012E Incorrect string specified for JCL EXEC parameter.

Explanation: The NetView Access Services BatchLoad options specified in the PARM field of the JCLEXEC statement are incorrect.

System Action: Processing is terminated.

User Response: Use the previous messages written inthe report output data set to correct the options.

EMS5013E Not enough storage in the region.

Explanation: The default region size or the valuespecified in the REGION parameter of your JCL JOB orEXEC statement is too small.

System Action: Processing is terminated.

User Response: Specify a higher region size. Aregion size of 1MB (MB equals 1 048 576) is normallyadequate.

EMS5014I Data set dddddddd is empty. The end_of_file recordis inserted.

Explanation: When the profile data set is empty, as afirst step the end_of_file record containing all X'FF'characters is inserted into the data set.

dddddddd = DD name of data set.

System Action: Program continues.

User Response: Check if your profile data set wasnewly allocated via VSAM.

EMS5015E Locking of the NV/AS database is impossible.

Explanation: During the previous run of the NetViewAccess Services Batch Load utility a serious erroroccurred (return code = 20) and the NetView AccessServices database was not unlocked. The samemessage can occur when the NetView Access Servicesproduct terminates unattended.

System Action: Processing is terminated.

User Response: Add the UNLOCK option to theoption string specified in the JCL EXEC PARM specifi-cation and rerun the job. Remember to remove theUNLOCK option from the options string after successfulexecution of the job, because otherwise the lockingmechanism between the NetView Access Servicesproduct and the NetView Access Services Batch Loadutility does not work properly.

EMS5016E Mandatory option UID is not specified.

Explanation: The UID parameter is missing in theoptions string of the JCL EXEC PARM specification.

System Action: Processing is terminated.

User Response: Add your administrator user_ID in theUID option to the string specified in the JCL EXECPARM statement.

EMS5017E The UID option must specify an administratoruser_ID.

Explanation: The user_ID specified in the UID optionis not an administrator user_ID.

System Action: Processing is terminated.

User Response: Correct the UID option in the optionsstring specified in the JCL EXEC PARM statement.

EMS5020I BIND user data for an unknown application ssssssss.

Explanation: During the consistency check of theNetView Access Services database a bind_user_dataprofile was found with no correspondingsystem_application profile.

ssssssss = System_internal_name.

System Action: Program continues.

User Response: Define the correspondingsystem_application profile or delete the bind_user_dataprofile.

EMS5021I Unknown group name for SRTU record ( uuuuuuuu,gggggggg, aaaaaaaa).

Explanation: During the consistency check of theNetView Access Services database a user profile wasfound with no corresponding group profiles.

uuuuuuuu = User_IDgggggggg = Group_nameaaaaaaaa = Application_name.

System Action: Program continues.

User Response: Define the corresponding groupprofile, or delete the user profile.

If you intend to delete the user profile using the NetViewAccess Services batch load and reporting utility, youmust do the following:

� Define a normal group profile for the respectivegroup.

� Start the batch load and reporting utility again anddelete the respective group profile.

EMS5022I SRTU record for a public or external group(uuuuuuuu, gggggggg, aaaaaaaa).

Explanation: During the consistency check of theNetView Access Services database, a user profile wasfound for a public or external group. No user profilesare allowed for public groups.

For external groups, all user profile characteristics areheld on external media (for example, RACF), so noSRTU records are allowed in the NetView Access Ser-vices database.

uuuuuuuu = User_IDgggggggg = Group_nameaaaaaaaa = Application_name.

System Action: Program continues.

User Response: Change the group type of the respec-tive group to normal, or delete the user profiles.

If you intend to delete the user profiles using the batchload and reporting utility, you must do the following:

� Change the group type of the respective group tonormal.

80 NetView Access Services Version 2 Messages

Page 93: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS5023I � EMS5036E

� Start the batch load and reporting utility again anddelete the respective user profiles.

� Change the group type to public or external as itwas before.

EMS5023I Normal group gggggggg is useless if option NOSRTUis specified.

Explanation: During the consistency check of theNetView Access Services database, a normal group wasfound although you specified the option NOSRTU in theJCL EXEC PARM statement.

Specifying the NOSRTU option means that all your userprofiles are held on external media (for example,RACF), so your NetView Access Services databasemust only contain externally controlled groups and even-tually public groups.

gggggggg = Group_name.

System Action: Program continues.

User Response: Change the group type of the respec-tive group to external or public, or delete the groupprofile.

EMS5024I Unknown group name for GAL record ( gggggggg,uuuuuuuu).

Explanation: During the consistency check of theNetView Access Services database, an administratorauthorization profile was found with no correspondinggroup profile.

gggggggg = Group_nameuuuuuuuu = User_ID.

System Action: Program continues.

User Response: Define the corresponding groupprofile, or delete the administrator authorization profile.

EMS5025I Unknown group name for ALLT record ( uuuuuuuu,gggggggg, aaaaaaaa).

Explanation: During the consistency check of theNetView Access Services database, an ALLT recordwas found with no corresponding group profile.

uuuuuuuu = User_IDgggggggg = Group_nameaaaaaaaa = Application_name.

System Action: Program continues.

User Response: Define the respective group profile, ordelete the ALLT profile record.

If you intend to delete the ALLT record using the batchload and reporting utility, you must do the following:

� Define the respective normal group.� Start the batch load and reporting utility again and

delete the respective group.

EMS5026I No STRG record found for ALLT record ( uuuuuuuu,gggggggg, aaaaaaaa).

Explanation: During the consistency check of theNetView Access Services database, an ALLT recordwas found with no corresponding SRTG profile.

uuuuuuuu = User_IDgggggggg = Group_nameaaaaaaaa = Application_name.

System Action: Program continues.

User Response: Define the respective STRG profile,or delete the ALLT profile record.

If you intend to delete the ALLT record using the batchload and reporting utility, you must do the following:

� Define the respective STRG profile.� Start the batch load and reporting utility again and

delete the respective STRG profile.

EMS5030E Continuation line expected.

Explanation: The current command line is terminatedby a comma, but the following line does not contain acommand parameter specification.

System Action: Program continues.

User Response: Correct the error.

EMS5031E No comma specified for continuation.

Explanation: The current line is not terminated by acomma, but the following line contains a commandparameter specification.

System Action: Program continues.

User Response: Correct the error.

EMS5032E Unknown profile data set.

Explanation: The positional parameter on thecommand line specifying the profile-concerned data setis incorrect.

System Action: Program continues.

User Response: Correct the error.

EMS5033E Parameter not terminated correctly.

Explanation: The parameter value is incorrect or it isnot terminated by a comma or a blank.

System Action: Program continues.

User Response: Correct the error.

EMS5034E Incorrect parameter syntax.

Explanation: A parameter specification must consist ofthe parameter keyword followed by the character “=”,followed by the parameter value.

System Action: Program continues.

User Response: Correct the error.

EMS5035E Incorrect command syntax.

Explanation: A command must consist of thecommand word followed by one or more blank charac-ters, followed by the positional parameter specifying theconcerned profile.

System Action: Program continues.

User Response: Correct the error.

EMS5036E Unknown command.

Explanation: The command word is unknown.

System Action: Program continues.

User Response: Correct the error.

Chapter 3. Batch Load Messages 81

Page 94: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS5037E � EMS5409E

EMS5037E Unknown parameter.

Explanation: The parameter keyword is unknown or isinvalid for this profile data set.

System Action: Program continues.

User Response: Correct the error.

EMS5060E Error in the pppppppp parameter value.

Explanation: An error occurred in the parameter valueof the parameter pppppppp.

System Action: Program continues.

User Response: Correct the error.

EMS5139E APPLICATION_DESCRIPTION text longer than 30characters.

Explanation: The text specified in this parameter valuemust not be longer than 30 characters.

System Action: Program continues.

User Response: Correct the error.

EMS5240E pppppppp is already specified.

Explanation: The parameter pppppppp is specifiedtwice in the current command.

System Action: Program continues.

User Response: Correct the error.

EMS5285E The pppppppp must be a PA key (PA nn), a PF key(PFnn), the ATTN key, or blank.

Explanation: The function key specified for the param-eter pppppppp is incorrect.

System Action: Program continues.

User Response: Correct the error.

EMS5287E The COMMAND_KEY must be a PF key (PF nn) or theENTER key (ENTR).

Explanation: The COMMAND_KEY parameter value isincorrect.

System Action: Program continues.

User Response: Correct the error.

EMS5289E The pppppppp key must be a PF key (PF nn).

Explanation: The function key specified for the param-eter pppppppp is incorrect.

System Action: Program continues.

User Response: Correct the error.

EMS5290E The PRINT_KEY must be a PA key (PA nn), a PF key(PFnn) or empty.

Explanation: The function key specified is incorrect.

System Action: Program continues.

User Response: Correct the error.

EMS5315E Administration exit checking has rejected therequest.

Explanation: The administration exit EMSEADEX hasrejected the command.

Note: The calls to EMSEADEX in the execution phaseare issued after updating the corresponding profiles inthe NetView Access Services database. Therefore theprofile updates are executed anyway, and it may still benecessary to perform the RACF updates via TSO.

System Action: Program continues.

User Response: Correct the error.

EMS5389E pppppppp text is longer than 15 characters.

Explanation: The text specified in the ppppppppparameter is longer than 15 characters.

System Action: Program continues.

User Response: Correct the error.

EMS5400E xxx . . . xxx.

Explanation: The administration exit EMSEADEXreturned a message text that is inserted in thismessage.

System Action: Program continues.

User Response: See the description of yourEMSEADEX routine to correct the error.

EMS5406E Only system administrators may access adminis-trator authorization profiles.

Explanation: The user_ID specified in the UID optionon the JCL EXEC PARM statement is not that of asystem administrator.

System Action: Program continues.

User Response: Either specify a system administratoruser_ID on the UID option, or avoid executing com-mands on the administrator profile data set.

EMS5407E Mandatory parameter pppppppp is not specified.

Explanation: Parameter pppppppp is missing.

System Action: Program continues.

User Response: Correct the error.

EMS5408E System administrator uuuuuuuu is already defined.

Explanation: The system administrator uuuuuuuu isalready defined in the administrator profile data set.

System Action: Program continues.

User Response: Avoid defining this system adminis-trator again.

EMS5409E Administrator uuuuuuuu for group gggggggg isalready defined

Explanation: Administrator uuuuuuuu is alreadydefined for the group gggggggg.

uuuuuuuu = User_IDgggggggg = Group_name.

System Action: Program continues.

82 NetView Access Services Version 2 Messages

Page 95: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS5410E � EMS5423I

User Response: Avoid defining this administratoragain for this group.

EMS5410E Unknown system administrator uuuuuuuu.

Explanation: The system administrator uuuuuuuu isnot defined in the administrator profile data set.

uuuuuuuu = User_ID.

System Action: Program continues.

User Response: Define this system administrator oravoid executing other commands for it.

EMS5411E Unknown administrator uuuuuuuu for groupgggggggg.

Explanation: The administrator uuuuuuuu is notdefined for the group gggggggg.

uuuuuuuu = User_IDgggggggg = Group_name.

System Action: Program continues.

User Response: Define the administrator for the groupor avoid executing other commands for this adminis-trator.

EMS5412E EXIT_1 parameter is missing.

Explanation: You may not specify the EXIT_2 param-eter without specifying also the EXIT_1 parameter.

System Action: Program continues.

User Response: Correct the error.

EMS5413E Exit user data contains more than 60 characters.

Explanation: The concatenated text specified in theEXIT parameters is longer than 60 characters.

System Action: Program continues.

User Response: Correct the error.

EMS5414I System administrator uuuuuuuu has been replaced.

Explanation: Successful execution of the REPLACEcommand.

uuuuuuuu = User_ID.

System Action: Program continues.

User Response: None.

EMS5415I Administrator uuuuuuuu for group gggggggg hasbeen replaced.

Explanation: Successful execution of the REPLACEcommand.

uuuuuuuu = User_IDgggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5416I System administrator uuuuuuuu has been added.

Explanation: Successful execution of the ADDcommand.

uuuuuuuu = User_ID.

System Action: Program continues.

User Response: None.

EMS5417I Administrator uuuuuuuu for group gggggggg hasbeen added.

Explanation: Successful execution of the ADDcommand.

uuuuuuuu = User_IDgggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5418I System administrator uuuuuuuu has been deleted.

Explanation: Successful execution of the DELETEcommand.

uuuuuuuu = User_ID.

System Action: Program continues.

User Response: None.

EMS5419I Administrator uuuuuuuu for group gggggggg hasbeen deleted.

Explanation: Successful execution of the DELETEcommand.

uuuuuuuu = User_IDgggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5420I No administrator is defined.

Explanation: You used the LIST command to listadministrators, but the administrator profile data set isempty.

System Action: Program continues.

User Response: None.

EMS5421I No administrator is defined for group gggggggg.

Explanation: You used the LIST command to listadministrators, but no administrator is defined for thisgroup.

gggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5422I Unknown administrator uuuuuuuu.

Explanation: You used the LIST command to list anadministrator, but this administrator is not defined.

uuuuuuuu = User_ID.

System Action: Program continues.

User Response: None.

EMS5423I Parameters EXIT_1 and EXIT_2 are not allowed.

Explanation: The EXIT_1 and EXIT_2 parameters arenot allowed for this command.

System Action: Program continues.

User Response: Correct the error.

Chapter 3. Batch Load Messages 83

Page 96: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS5424E � EMS5440E

EMS5424E GROUP_NAME=* is not allowed for this command.

Explanation: The parameter value “*” is not allowedfor this command.

System Action: Program continues.

User Response: Correct the error.

EMS5425E USER_ID=* is not allowed for this command.

Explanation: The parameter value “*” is not allowedfor this command.

System Action: Program continues.

User Response: Correct the error.

EMS5426I No system administrator defined.

Explanation: You used the LIST command to listsystem administrators, but no administrator is defined inthe administrator profile data set.

System Action: Program continues.

User Response: None.

EMS5428I Unknown administrator uuuuuuuu for groupgggggggg.

Explanation: You used the LIST command to list anadministrator, but this administrator is not defined for therespective group.

uuuuuuuu = User_IDgggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5429E @SNAMES@ is a reserved group name.

Explanation: This group name is used for internal pur-poses, so you may not specify it.

System Action: Program continues.

User Response: Correct the error.

EMS5431E Parameter TYPE is not allowed in combination withparameter GROUP_NAME.

Explanation: The parameter TYPE is only required tospecify a broadcast administrator. It is not allowed for acommand related to a group administrator.

System Action: Program continues.

User Response: Correct the error.

EMS5432E Parameter TYPE is not allowed for UPD and REPcommands.

Explanation: The parameter TYPE is only allowed forADD, DEL, and LIST commands.

System Action: Program continues.

User Response: Correct the error.

EMS5433E uuuuuuuu is already defined as a system adminis-trator.

Explanation: The system administrator uuuuuuuu isalready defined in the administrator profile data set.

System Action: Program continues.

User Response: Correct the error.

EMS5434E uuuuuuuu is already defined as a broadcast adminis-trator.

Explanation: You have tried to define a user as asystem administrator, but the user is defined as a broad-cast administrator in the administrator profile data set.

uuuuuuuu = User_ID.

System Action: Program continues.

User Response: Correct the error.

EMS5435E Broadcast administrator uuuuuuuu is already defined.

Explanation: The broadcast administrator uuuuuuuu isalready defined in the administrator profile data set.

System Action: Program continues.

User Response: Correct the error.

EMS5436E Broadcast administrator uuuuuuuu has been added.

Explanation: Successful execution of the ADDcommand.

uuuuuuuu = User_ID.

System Action: Program continues.

User Response: Correct the error.

EMS5437E Broadcast administrator uuuuuuuu has been deleted.

Explanation: Successful execution of the DELETEcommand.

uuuuuuuu = User_ID.

System Action: Program continues.

User Response: Correct the error.

EMS5438E Unknown broadcast administrator uuuuuuuu.

Explanation: The broadcast administrator uuuuuuuu isnot defined in the administrator profile data set.

System Action: Program continues.

User Response: Correct the error.

EMS5440E Only system administrators can access BIND userdata profiles.

Explanation: The user_ID specified in the UID optionof your JCL EXEC PARM statement is not a systemadministrator.

System Action: Program continues.

User Response: Specify a system administrator in theUID option or avoid access to bind_user_data profiles.

84 NetView Access Services Version 2 Messages

Page 97: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS5442E � EMS5456I

EMS5442E Unknown system application ssssssss.

Explanation: The respective system_application profileis not defined, so the execution of commands con-cerning this system_application is meaningless.

ssssssss = System_internal_name.

System Action: Program continues.

User Response: Define the respectivesystem_application profile or avoid executing commandsconcerning this system application.

EMS5443E BIND user data already defined for system applica-tion ssssssss.

Explanation: The bind_user_data profile is alreadydefined for this system_application.

ssssssss = System_internal_name.

System Action: Program continues.

User Response: Avoid defining the bind_user_dataagain.

EMS5444E No BIND user data defined for system applicationssssssss.

Explanation: The bind_user_data profile is not definedfor this system_application.

ssssssss = System_internal_name.

System Action: Program continues.

User Response: Define the respective bind_user_dataprofile or avoid executing other commands on it.

EMS5445E Parameters BIND_1 - BIND_5 not allowed.

Explanation: The BIND_1 - BIND_5 parameters arenot allowed for this command.

System Action: Program continues. The command inerror is not executed.

User Response: Correct the error.

EMS5447E The BIND parameters must be specified in ascendingorder.

Explanation: You may not use a certain BIND param-eter (for instance BIND_3) without specifying all pre-ceding BIND parameters (in this case BIND_1 andBIND_2).

System Action: Program continues.

User Response: Correct the error.

EMS5448E BIND user data contains more than 255 characters.

Explanation: The concatenated text specified in theBIND parameter values is longer than 255 characters.

System Action: Program continues.

User Response: Correct the error.

EMS5449I BIND user data for system application ssssssss hasbeen replaced.

Explanation: Successful execution of the REPLACEcommand.

ssssssss = System_internal_name.

System Action: Program continues.

User Response: None.

EMS5450I BIND user data for system application ssssssss hasbeen added.

Explanation: Successful execution of the ADDcommand.

ssssssss = System_internal_name.

System Action: Program continues.

User Response: None.

EMS5451I BIND user data for system application ssssssss hasbeen updated.

Explanation: Successful execution of the UPDATEcommand.

ssssssss = System_internal_name.

System Action: Program continues.

User Response: None.

EMS5452I BIND user data for system application ssssssss hasbeen deleted.

Explanation: Successful execution of the DELETEcommand.

ssssssss = System_internal_name.

System Action: Program continues.

User Response: None.

EMS5453I No system application with BIND user data found.

Explanation: You used the LIST command to list BINDuser data, but the bind_user_data profile data set isempty.

System Action: Program continues.

User Response: None.

EMS5454E SYSTEM_INTERNAL_NAME=* is not allowed in thiscommand.

Explanation: The parameter value “*” is not allowed inthis command.

System Action: Program continues.

User Response: Correct the error.

EMS5455I Unknown system application ssssssss.

Explanation: You used the LIST command to list asystem application, but you specified an unknownsystem_application.

ssssssss = System_internal_name.

System Action: Program continues.

User Response: Correct the error.

EMS5456I No BIND user data is defined for system applicationssssssss.

Explanation: You used the LIST command to list BINDuser data for a system application, but nobind_user_data profile is defined for thissystem_application.

Chapter 3. Batch Load Messages 85

Page 98: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS5457E � EMS5492E

ssssssss = System_internal_name.

System Action: Program continues.

User Response: None.

EMS5457E Parameters BIND_1 - BIND_5 not allowed.

Explanation: The BIND_1 - BIND_5 parameters arenot allowed for this command.

System Action: Program continues. The command inerror is not executed.

User Response: Correct the error.

EMS5471E Group gggggggg already defined.

Explanation: The respective group profile is alreadydefined.

gggggggg = Group_name.

System Action: Program continues.

User Response: Avoid defining the respective groupprofile again.

EMS5472E Unknown group gggggggg.

Explanation: This group profile is not defined.

gggggggg = Group_name.

System Action: Program continues.

User Response: Define the respective group profile oravoid executing other commands on it.

EMS5475I Group gggggggg has been replaced.

Explanation: Successful execution of the REPLACEcommand.

gggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5476I Group gggggggg has been added.

Explanation: Successful execution of the ADDcommand.

gggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5477I Group gggggggg has been updated.

Explanation: Successful execution of the UPDATEcommand.

gggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5478E Parameter pppppppp is not allowed.

Explanation: The parameter pppppppp is not allowedon this command.

System Action: Program continues.

User Response: Correct the error.

EMS5487I User uuuuuuuu for application aaaaaaaa in groupgggggggg has been deleted.

Explanation: Successful execution of the DELETEcommand.

uuuuuuuu = User_IDaaaaaaaa = Application_namegggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5488I Application aaaaaaaa has been deleted from groupgggggggg.

Explanation: Successful execution of the DELETEcommand.

aaaaaaaa = Application_namegggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5489I Group gggggggg has been deleted.

Explanation: Successful execution of the DELETEcommand.

gggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5490I No group profile defined.

Explanation: You used the LIST command to list agroup profile, but the group profiles data set is empty.

System Action: Program continues.

User Response: None.

EMS5491I Only parameter GROUP_NAME is allowed.

Explanation: On the LIST command no other parame-ters are allowed.

System Action: Program continues.

User Response: Correct the error.

EMS5492E Only system administrators have access to allgroups.

Explanation: Your user_ID specified in the UID optionof the JCL EXEC PARM statement is not that of asystem administrator.

System Action: Program continues.

User Response: Specify a system administratoruser_ID in the UID option or avoid executing commandsconcerning all groups.

86 NetView Access Services Version 2 Messages

Page 99: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS5493E � EMS5520I

EMS5493E You are neither a system administrator nor groupadministrator for this group.

Explanation: Your user_ID specified in the UID optionof the JCL EXEC PARM statement is neither a systemadministrator nor an administrator for this group.

System Action: Program continues.

User Response: Specify a system administrator or anadministrator for this group in the UID option or avoidexecuting commands concerning this group.

EMS5496I Unknown group gggggggg.

Explanation: You used the LIST command to list agroup, but the respective group profile is not defined.

gggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5497I ALLT record for user uuuuuuuu application aaaaaaaain group gggggggg has been deleted.

Explanation: Successful execution of the DELETEcommand.

uuuuuuuu = User_IDaaaaaaaa = Application_namegggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5498E GROUP_TYPE must not be changed.

Explanation: You tried to change the group_type.However, different databases are used to store the data.

System Action: Program continues.

User Response: Delete the respective group profile,redefine it for the group_type, and use the ADDcommand.

EMS5499E GROUP_TYPE=NORMAL not allowed if optionNOSRTU is specified.

Explanation: If the option NOSRTU is specified, thenall user profile characteristics are held on external media(for example, RACF), so only externally controlledgroups and eventually public groups are allowed.

System Action: Program continues.

User Response: Avoid defining normal groups, orverify that you really need the NOSRTU option.

EMS5500E Exit user exit data are only defined for externalgroups.

Explanation: You tried to define or update a groupprofile specifying user exit data parameters, but thegroup_type is not external.

System Action: Program continues.

User Response: Do not specify user exit data whenadding or updating group profiles for groups other thanexternal.

EMS5511E Parameter APPLICATION orSYSTEM_INTERNAL_NAME should be specified.

Explanation: One of these two parameters must bespecified in this command.

System Action: Program continues.

User Response: Correct the error.

EMS5514E Application aaaaaaaa not defined for groupgggggggg.

Explanation: The group_application profile is notdefined.

aaaaaaaa = Application_namegggggggg = Group_name.

System Action: Program continues.

User Response: Define the respectivegroup_application profile or avoid executing other com-mands related to it.

EMS5515E Application aaaaaaaa already defined for the groupgggggggg.

Explanation: The respective group_application profileis already defined.

aaaaaaaa = Application_namegggggggg = Group_name.

System Action: Program continues.

User Response: Avoid defining this group_applicationprofile again.

EMS5516E SYSTEM_INTERNAL_NAME not allowed for the freeselection application.

Explanation: For the free selection application “........”the parameter SYSTEM_INTERNAL_NAME is meaning-less.

System Action: Program continues.

User Response: Correct the error.

EMS5519I Application aaaaaaaa of group gggggggg has beenreplaced.

Explanation: Successful execution of the REPLACEcommand.

aaaaaaaa = Application_namegggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5520I Application aaaaaaaa has been added to groupgggggggg.

Explanation: Successful execution of the ADDcommand.

aaaaaaaa = Application_namegggggggg = Group_name.

System Action: Program continues.

User Response: None.

Chapter 3. Batch Load Messages 87

Page 100: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS5521I � EMS5566E

EMS5521I Application aaaaaaaa of group gggggggg has beenupdated.

Explanation: Successful execution of the UPDATEcommand.

aaaaaaaa = Application_namegggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5522I Only parameters GROUP_NAME and APPLICATIONare allowed.

Explanation: Only these 2 parameters are allowed inthis command.

System Action: Program continues.

User Response: Correct the error.

EMS5524I DATA_COMPRESSION=F not allowed withVIRTUAL_TERMINAL=N.

Explanation: You have specified Virtual Terminal Nand Data Compression F (full). Full data compression(outbound and inbound) is only possible with Virtual Ter-minal option Y.

System Action: Program continues.

User Response: Correct the error.

EMS5531I No application is defined for any group.

Explanation: You used the LIST command to listapplications, but the group_application data set isempty.

System Action: Program continues.

User Response: None.

EMS5532I Application aaaaaaaa not defined for any group.

Explanation: You used the LIST command to list anapplication, but the respective application is not definedfor any group.

aaaaaaaa = Application_name.

System Action: Program continues.

User Response: None.

EMS5533I System application ssssssss is not defined for anygroup.

Explanation: You used the LIST command to list asystem application, but the respectivesystem_application is not defined for any group.

ssssssss = System_internal_name.

System Action: Program continues.

User Response: None.

EMS5534I No application defined for group gggggggg.

Explanation: You used the LIST command to listapplications, but no application is defined for the respec-tive group.

gggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5535I System application ssssssss not defined for groupgggggggg.

Explanation: You used the LIST command to list asystem application, but the system_application is notdefined for the respective group.

ssssssss = System_internal_namegggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5538E Only one of the parameters APPLICATION andSYSTEM_INTERNAL_NAME should be specified.

Explanation: These two parameters exclude eachother.

System Action: Program continues.

User Response: Correct the error.

EMS5540E APPLICATION=* is not allowed in this command.

Explanation: The parameter value “*” is not allowedfor this command.

System Action: Program continues.

User Response: Correct the error.

EMS5543I Application aaaaaaaa not defined for groupgggggggg.

Explanation: You used the LIST command to list anapplication, but no profile is defined for this applicationand group.

aaaaaaaa = Application_namegggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5544I Only parameters GROUP_NAME and eitherSYSTEM_INTERNAL_NAME or APPLICATION areallowed.

Explanation: Only these two parameters are allowedon this command.

System Action: Program continues.

User Response: Correct the error.

EMS5564E Only system administrators may access the systemapplication profiles.

Explanation: Your user_ID specified in the UID optionof the JCL EXEC PARM statement is not that of asystem administrator.

System Action: Program continues.

User Response: Specify a system administratoruser_ID in the UID option or avoid executing commandsrelated to system_application profiles.

EMS5566E System application ssssssss already defined.

Explanation: The respective system_application profileis already defined.

88 NetView Access Services Version 2 Messages

Page 101: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS5568E � EMS5593E

ssssssss = System_internal_name.

System Action: Program continues.

User Response: Avoid defining thissystem_application profile again.

EMS5568E PSEUDO_TERMINAL_PREFIX is mandatory ifACCESS_TYPE = ttttt.

Explanation: The PSEUDO_TERMINAL_PREFIX mustbe specified for the respective access type.

tttt = Access_type.

System Action: Program continues.

User Response: Specify thePSEUDO_TERMINAL_PREFIX, or change theACCESS_TYPE.

EMS5569E MAXIMUM_SESSIONS should not be greater thansssss.

Explanation: The MAXIMUM_SESSIONS parameterconflicts with the length of thePSEUDO_TERMINAL_PREFIX.

sssss = Maximum_sessions.

System Action: Program continues.

User Response: Specify less MAXIMUM_SESSIONSor shorten the PSEUDO_TERMINAL_PREFIX name.

EMS5570E ACCESS_TYPE= ttttt is not allowed withSYSTEM_INTERNAL_NAME =$$INFO$$

Explanation: $$INFO$$ is a reservedSYSTEM_INTERNAL_NAME that implies theACCESS_TYPE=PASS.

ttttt = Access_type.

System Action: Program continues.

User Response: Correct the error.

EMS5571E PRIMARY_LU_NAME mandatory if ACB_TYPE notNO.

Explanation: If the value for the parameterACB_TYPE is not NO, the PRIMARY_LU_NAMEparameter is mandatory.

System Action: Program continues.

User Response: Either specify ACB_TYPE=NO, oradd the PRIMARY_LU_NAME parameter.

EMS5572I System application ssssssss has been replaced.

Explanation: Successful execution of the REPLACEcommand. The application has been replaced.

ssssssss = System_internal_name.

System Action: Program continues.

User Response: None.

EMS5573I System application ssssssss has been added.

Explanation: Successful execution of the ADDcommand.

ssssssss = System_internal_name.

System Action: Program continues.

User Response: None.

EMS5574I System application ssssssss has been updated.

Explanation: Successful execution of the UPDATEcommand.

ssssssss = System_internal_name.

System Action: Program continues.

User Response: None.

EMS5585I System application ssssssss has been deleted.

Explanation: Successful execution of the DELETEcommand.

ssssssss = System_internal_name.

System Action: Program continues.

User Response: None.

EMS5586E pppppppp in conflict withPSEUDO_TERMINAL_PREFIX qqqqqqqq of applica-tion ssssssss.

Explanation: Error occurred, because thePSEUDO_TERMINAL_PREFIX pppppppp is in conflictwith the PSEUDO_TERMINAL_PREFIX qqqqqqqq ofthe application ssssssss.

pppppppp = Pseudo_terminal_prefixqqqqqqqq = Pseudo_terminal_prefix of

applicationssssssss = System_internal_name.

System Action: Program continues.

User Response: Change thePSEUDO_TERMINAL_PREFIX of thissystem_application or change thePSEUDO_TERMINAL_PREFIX of system_applicationssssssss.

EMS5587I No system application is defined.

Explanation: You used the LIST command to list asystem application, but the system_application profiledata set is empty.

System Action: Program continues.

User Response: None.

EMS5590I Only parameter SYSTEM_INTERNAL_NAME isallowed.

Explanation: Only the parameterSYSTEM_INTERNAL_NAME is allowed in thiscommand.

System Action: Program continues.

User Response: Correct the error.

EMS5593E TPN_OF_ASR required if ACB_TYPE=NO.

Explanation: You specified ACB_TYPE=NO withoutspecifying the TPN_OF_ASR.

System Action: Program continues.

User Response: Either specify the TPN_OF_ASR, orchange the ACB_TYPE parameter from NO to anothervalue.

Chapter 3. Batch Load Messages 89

Page 102: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS5594E � EMS5628E

EMS5594E pppppppp not allowed if ACB_TYPE=NO.

Explanation: You specified ACB_TYPE=NO togetherwith either the PRIMARY_LU_NAME orBACKUP_APPLICATION_NAME.

System Action: Program continues.

User Response: Either delete thePRIMARY_LU_NAME orBACKUP_APPLICATION_NAME parameter, or changethe ACB_TYPE parameter from NO to another value.

EMS5595E PSEUDO_TERMINAL_PREFIX not allowed ifACB_TYPE=NO.

Explanation: You specified ACB_TYPE=NO togetherwith the PSEUDO_TERMINAL_PREFIX.

System Action: Program continues.

User Response: Either delete thePSEUDO_TERMINAL_PREFIX parameter, or changethe ACB_TYPE parameter from NO to another value.

EMS5596E ACCESS_TYPE=RELAY required if ACB_TYPE=NO.

Explanation: You specified ACB_TYPE=NO togetherwith a value for ACCESS_TYPE that is not RELAY.

System Action: Program continues.

User Response: Either change the value for param-eter ACCESS_TYPE to RELAY, or change theACB_TYPE parameter from NO to another value.

EMS5597E ACB_TYPE=NO required if TPN_OF_ASR specified.

Explanation: You specified TPN_OF_ASR withoutspecifying ACB_TYPE=NO.

System Action: Program continues.

User Response: Either delete the TPN_OF_ASRparameter, or change the ACB_TYPE parameter to NO.

EMS5605E No applications defined for group gggggggg.

Explanation: No group_application profiles are definedfor the respective group.

gggggggg = Group_name.

System Action: Program continues.

User Response: Define group_application profiles forthe group or avoid executing commands for applicationsconcerning this group.

EMS5607E No users defined for group gggggggg.

Explanation: No user profiles are defined for therespective group.

gggggggg = Group_name.

System Action: Program continues.

User Response: Define user profiles for this group oravoid executing commands for user profiles concerningthis group.

EMS5621E Application aaaaaaaa already defined for useruuuuuuuu in group gggggggg.

Explanation: The respective user profile is alreadydefined.

aaaaaaaa = Application_nameuuuuuuuu = User_IDgggggggg = Group_name.

System Action: Program continues.

User Response: Avoid defining the respective userprofile again.

EMS5622E Parameter SELECTION_ID not allowed for the freeselection application.

Explanation: The SELECTION_ID parameter is notallowed for the free selection application “........”.

System Action: Program continues.

User Response: Correct the error.

EMS5623E Either USER_ID or APPLICATION should specify avalid name.

Explanation: Both parameter values cannot be “*”.One must contain a valid name.

System Action: Program continues.

User Response: Correct the error.

EMS5625E Application aaaaaaaa not defined for any user ingroup gggggggg.

Explanation: No user profile defined for the respectiveapplication and group.

aaaaaaaa = Application_namegggggggg = Group_name.

System Action: Program continues.

User Response: Avoid executing commands on userprofiles concerning this application and group.

EMS5626E Application aaaaaaaa not defined for user uuuuuuuuin group gggggggg.

Explanation: The respective user profile is not defined.

aaaaaaaa = Application_nameuuuuuuuu = User_IDgggggggg = Group_name.

System Action: Program continues.

User Response: Avoid executing commands con-cerning the respective user profile.

EMS5627E USER_ID=* is not allowed for this command.

Explanation: The parameter value “*” is not allowedfor this command.

System Action: Program continues.

User Response: Correct the error.

EMS5628E No application defined for user uuuuuuuu in groupgggggggg.

Explanation: No user profile defined for the respectiveuser and group.

uuuuuuuu = User_IDgggggggg = Group_name.

System Action: Program continues.

User Response: Avoid executing commands con-cerning this user and group.

90 NetView Access Services Version 2 Messages

Page 103: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS5632I � EMS5651I

EMS5632I No user defined for any group.

Explanation: You used the LIST command to listusers, but no user profile is defined for the respectivegroup.

System Action: Program continues.

User Response: None.

EMS5633I User uuuuuuuu not defined in any group.

Explanation: You used the LIST command to list auser, but no user profile is defined for the respectiveuser.

uuuuuuuu = User_ID.

System Action: Program continues.

User Response: None.

EMS5634I Application aaaaaaaa not defined for any user innormal groups.

Explanation: You used the LIST command to list anapplication, but no user profile is defined concerning therespective application.

aaaaaaaa = Application_name.

System Action: Program continues.

User Response: None.

EMS5635I Application aaaaaaaa not defined for user uuuuuuuuin any group.

Explanation: You used the LIST command to list anapplication, but no user profile is defined concerning therespective application and user.

aaaaaaaa = Application_nameuuuuuuuu = User_ID.

System Action: Program continues.

User Response: None.

EMS5639I User uuuuuuuu for application aaaaaaaa in groupgggggggg has been replaced.

Explanation: Successful execution of the REPLACEcommand.

uuuuuuuu = User_IDaaaaaaaa = Application_namegggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5640I User uuuuuuuu has been added to applicationaaaaaaaa in group gggggggg.

Explanation: Successful execution of the ADDcommand.

uuuuuuuu = User_IDaaaaaaaa = Application_namegggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5641I User uuuuuuuu for application aaaaaaaa in groupgggggggg has been updated.

Explanation: Successful execution of the UPDATEcommand.

uuuuuuuu = User_IDaaaaaaaa = Application_namegggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5647I Application aaaaaaaa is not defined for useruuuuuuuu in the group gggggggg.

Explanation: You used the LIST command to list anapplication, but no user profile is defined for the respec-tive user, application, and group.

aaaaaaaa = Application_nameuuuuuuuu = User_IDgggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5648I No users are defined for group gggggggg.

Explanation: You used the LIST command to listusers, but no user profiles are defined for this group.

gggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5649I No application defined for user uuuuuuuu in groupgggggggg.

Explanation: You used the LIST command to list anapplication, but no user profiles are defined for therespective user and group.

uuuuuuuu = User_IDgggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5650I Application aaaaaaaa not defined for any user ingroup gggggggg.

Explanation: You used the LIST command to list anapplication, but no user profiles are defined for therespective application and group.

aaaaaaaa = Application_namegggggggg = Group_name.

System Action: Program continues.

User Response: None.

EMS5651I Only parameters USER_ID, GROUP_NAME andAPPLICATION allowed.

Explanation: No other parameters are allowed in thiscommand.

System Action: Program continues.

User Response: Correct the error.

Chapter 3. Batch Load Messages 91

Page 104: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS5652E � EMS5702E

EMS5652E No user profiles may be defined for groups withGROUP_TYPE=PUBLIC.

Explanation: No user profiles can be defined forgroups of type other than NORMAL.

System Action: Program continues.

User Response: Correct the error.

EMS5654E Commands for external groups with USER_ID=* arenot allowed.

Explanation: The implementation concept of externallycontrolled groups does not allow the execution of com-mands for all users defined in the externally controlledgroup.

System Action: Program continues.

User Response: Repeat the command explicitly speci-fying the user_ID for each intended user.

EMS5655E Return code rrrrr received from EMSEADEX (cmd =cccccccc, uid = uuuuuuuu, group = gggggggg, appl =aaaaaaaa).

Explanation: An error was returned by the adminis-tration exit EMSEADEX.

rrrr = Return codecccccccc = EMSEADEX commanduuuuuuuu = User_IDgggggggg = Groupaaaaaaaa = Application_name.

System Action: Program continues.

User Response: Consult the description of yourEMSEADEX routine to correct the error.

EMS5656E If option NOSRTU is specified then user profiles fornormal groups are not allowed.

Explanation: Specifying the NOSRTU option meansthat all your user profiles are held on external media (forexample, RACF), so definitions of user profiles fornormal groups are not allowed.

System Action: Program continues.

User Response: Avoid defining user profiles fornormal groups, or check if you really need the NOSRTUoption.

EMS5668E APPLICATION_ID_DISPLAY = Y not allowed by thecorresponding GROUP_APPLICATION profile.

Explanation: The correspondingGROUP_APPLICATION profile containsAPPLICATION_ID_DISPLAY = N. Therefore, theparameter cannot be changed to Y in the USER profile.

System Action: Program continues.

User Response: Either specifyAPPLICATION_ID_DISPLAY = Y in theGROUP_APPLICATION profile, orAPPLICATION_ID_DISPLAY = N in the USER profile.

EMS5670E Operation option is specified twice.

Explanation: The operation option has already beenspecified.

System Action: Processing is terminated.

User Response: Correct the error.

EMS5671E oooooooo option is specified twice.

Explanation: The option oooooooo is specified twice.

oooooooo = Option.

System Action: Processing is terminated.

User Response: Correct the error.

EMS5677E Error in the options string.

Explanation: The options string specified in the JCLEXEC PARM statement is not correct.

System Action: Processing is terminated.

User Response: Correct the error.

EMS5678E Error in the oooooooo option specification.

Explanation: Error occurred in the respective option.

oooooooo = Option.

System Action: Processing is terminated.

User Response: Correct the error.

EMS5680E Unknown option.

Explanation: An unknown option was encountered inthe options string.

System Action: Program continues.

User Response: Correct the error.

EMS5690I Invalid field ff found in user data array for useruuuuuuuu in group gggggggg.

Explanation: An invalid field ID was found whenparsing the user data array by a call to the adminis-tration exit EMSEADEX with the command codeGETAPPLS.

ff = Field_IDuuuuuuuu = User_IDgggggggg = Group_name.

System Action: Program continues.

User Response: Check your administration exitEMSEADEX for an error in the processing of user dataarray information.

EMS5702E APPLSTAT_TIME_VALUE must be 0 if ACB_TYPE =N.

Explanation: The value for APPLSTAT_TIME_VALUEmust be 0 for ACB_TYPE = N.

System Action: Program continues.

User Response: Either specify another value forACB_TYPE or 0 for the APPLSTAT_TIME_VALUE.

92 NetView Access Services Version 2 Messages

Page 105: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

EMS5720E � EMS5943I

EMS5720E DEFAULT_APPLICATION = YES not allowed for thefree selection application.

Explanation: The value YES in theDEFAULT_APPLICATION parameter is not allowed forthe free selection application.

System Action: Program continues.

User Response: Correct the error.

EMS5904I Locking of the NV/AS database has failed. BatchLoad retries each ttttt seconds.

Explanation: The NetView Access Services databaseis locked at this moment. Batch Load waits a certainamount of time and retries again. After 30 retry oper-ations the job is canceled.

tttt = Wait time in seconds.

System Action: Program continues.

User Response: Use the NetView Access ServicesBatch Load option UNLOCK the next time you executethe job, but remember to remove this option after suc-cessful completion of the job because otherwise thelocking mechanism of the NetView Access Servicesdatabase will be disabled.

EMS5931E xxxx error in data set dddddddd. Return code = rrrrr.Reason code = sssss.

Explanation: Error occurred during a certain VSAMoperation or the respective data set.

xxxx = VSAM operation or modedddddddd = DD name of data setrrrr = Return_codessss = Reason_code.

System Action: Processing is terminated.

User Response: Check whether the respective dataset is correctly defined in the respective DD statementand is correctly allocated.

EMS5937E Data set dddddddd not KSDS organized.

Explanation: Error occurred, because the data set withthis DD name is not a KSDS data set.

dddddddd = DD name of data set.

System Action: Processing is terminated.

User Response: Check whether the respective dataset is correctly defined in the respective DD statement,and is correctly allocated.

EMS5938E mmmmmmmm failed RC = rrr.

Explanation: Severe error occurred, a certain modulefailed. Where possible the error is described in a pre-vious error message.

mmmmmmmm = Name of the module that failedrrr = Return code.

System Action: Processing is terminated with the jobreturn code 20.

User Response: If the message is preceded byanother message describing the error, then execute therecovery actions documented in the respective errormessage description. Otherwise, perform the problemdetermination procedures.

EMS5939E Wrong function key found in the profile data setpppp.

Explanation: Function codes are held in the profiledata set in their 3270 encoded format. During theediting of the profile listings these function codes areconverted into their external format, for example, PF1.This message occurs if the NetView Access ServicesBatch Load utility finds an unknown function code in therespective profile record.

pppp = Name of the profile data set.

System Action: Processing is terminated with the job-return code 20.

User Response: Check if the respective profile dataset is correctly defined in your DD statement and that ithas the correct record structure.

EMS5940E mmmmmmmm failure on VSAM data set, RC= rr.

Explanation: An Enqueue or Dequeue macro failedwhen trying to lock or unlock a VSAM data set.mmmmmmmm is Enqueue or Dequeue.

System Action: Program terminates.

User Response: Check VSAM return code.

EMS5941E DYNALLOC failed for DD name dddddddd, RC=rr,S99INFO=yyy, S99ERROR=xx.

Explanation: A DYNALLOC macro call failed for DDname dddddddd. This can happen if you omit SRTUDD name in your JCL.

System Action: Program terminates.

User Response: Check SVC 99 return and sensecodes.

EMS5943I BATCH LOAD COMPLETED. RC = x.

Explanation: Batch load has completed with returncode x.

System Action: Program terminates.

User Response: None.

Chapter 3. Batch Load Messages 93

Page 106: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

94 NetView Access Services Version 2 Messages

Page 107: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

Part 2. Glossary and Bibliography

Copyright IBM Corp. 1987, 1997 95

Page 108: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

96 NetView Access Services Version 2 Messages

Page 109: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

Glossary

This glossary defines terms as they are used in this book. Ifyou do not find the terms you are looking for, refer to Dic-tionary of Computing, SC20-1699.

ACB . Access Method Control Block. A control block thatlinks an application program to VSAM or VTAM.

access . In RACF, the ability to obtain use of a protectedresource.

access mode . In NetView Access Services, the type ofaccess a user can have to an application. There is relaymode, pass mode, or both.

administration . The process of designing, controlling, andmanaging the use of NetView Access Services or a NetViewAccess Services group.

administrator . A person who organizes applications intogroups, assigns applications to the users, and defines certainparameters for the system, groups, users, and applications.

application . In NetView Access Services, an applicationprogram, system, or subsystem.

application session . In NetView Access Services, asession between NetView Access Services and an applica-tion.

APPL statement . In VTAM, a statement identifying anapplication to VTAM.

ASR. Application Service Routine. In NetView Access Ser-vices, a service routine that communicates with applicationsthrough the communication services of NetView Access Ser-vices and then VTAM.

ASR-to-ASR communication . In NetView Access Services,a function that implements a link between the ASRs of thesame NetView Access Services through the communicationservices of NetView Access Services without traversingVTAM.

automatic logon . In NetView Access Services, the processof creating a logon from NetView Access Services to anapplication.

automatic logon authorization . In NetView Access Ser-vices, the right to use the automatic logon function.

BIND. In SNA products, a request to activate a sessionbetween two logical units.

BIND user data . In SNA, data, which relates to a user, thatis sent with a BIND request.

broadcast message . In NetView Access Services, amessage that is transmitted to the Application Selectionpanels of all users on the system.

CICS/VS. Customer Information System/Virtual Storage. AnIBM licensed program used in a communications network. Itis a transaction manager that provides database and datacommunications support of transaction programs.

command key . In NetView Access Services, the key that isused when in an application, to send a command to NetViewAccess Services.

command prefix . A string of characters that is used, whenin an application, to denote the beginning of a command thatis sent to NetView Access Services.

default application . When specified, the application that isassumed if none is entered on the Logon panel.

default group . The group with which a user is associatedwhen no group name is entered on the Logon panel.

disconnecting . The process of breaking the connectionwith NetView Access Services temporarily, while keeping allcurrent application sessions active.

escape key . The key you use when you are in an applica-tion panel to display the Application Selection panel on thescreen, without logging off or disconnecting from that applica-tion.

field . A specified area used for a particular type of data.

filing . In NetView Access Services, the process of storing alogon or logoff sequence in a file called a profile.

group . A set of applications bound by common criteria.The system administrator decides the criteria used to definegroups and how to associate users with different groups.There are three types of groups: Normal, Public, andExternal.

group administrator . The person who administers a group.

help panel . See second-level help.

idle time . The part of operable time during which a programis not used.

input field . A field on a panel where a user can enter data.

jump key . The key need to jump from the current applica-tion to another application.

keyword parameter . A parameter that consists of akeyword, followed by one or more values. See also posi-tional parameter.

location . A place where NetView Access Services isinstalled.

logging on . The process of opening a session with anapplication.

Copyright IBM Corp. 1987, 1997 97

Page 110: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

logoff sequence . A sequence of data recorded during alogoff.

logon profile . A file containing a logon sequence, plus anyalternative sequences, and a logoff sequence, if one hasbeen recorded. This file is used by NetView Access Ser-vices for automatic logon and logoff, if a logoff sequence hasbeen recorded.

logon sequence . A sequence of data recorded during alogon procedure. For example, variables for the user ID andpassword, and any other information necessary to completethe logon to a particular application that can be used byNetView Access Services to perform the logon automaticallyfor the user.

LU. logical unit. In SNA, a port through which a user gainsaccess to the SNA network to communicate with anotheruser and through which the user gains access to the func-tions provided by the system. An LU can support at leasttwo sessions, and might be capable of many sessions withother LUs.

LU name . In programming, a name used to represent aninput/output unit.

mode . A method of operation. See pass mode, relaymode.

multiterminal authorization . The authorization to belogged on at more than one terminal at a time.

MVS/ESA. Multiple Virtual Storage/Enterprise System Archi-tecture. An IBM licensed program whose full name is Oper-ating System/Virtual Storage (OS/VS) with Multiple VirtualStorage/System Product for System/370. It is a softwareoperating system controlling the execution of programs.

NetView . An IBM licensed program consisting of a base forcommand processors that can monitor, control, and improvethe operation of a network.

network . A configuration of data processing and softwareconnected for information interchange. See also SNAnetwork.

operator . A person who operates a device or a system.

operator console . A display console used for communi-cation between the operator and the system, used primarilyto specify information concerning application programs, andto monitor the system.

panel . The complete set of information shown in a singledisplay on a screen. Each panel is like a manual page.

pass mode . In NetView Access Services, the mode youuse to select an application when NetView Access Servicespasses control to the application.

PLU. Primary logical unit.

positional parameter . A parameter that must appear in aspecified location relative to other positional parameters.See also keyword parameter.

primary logical unit . In SNA, the LU that contains theprimary half-session for a particular LU-to-LU session. Con-trast with secondary logical unit. See LU.

problem determination . The process of determining thesource of a problem; for example, a program component,machine failure, user-installed programs or equipment, envi-ronmental failure such as a power loss, or a user error.

profile . Data that describes the significant characteristics ofa user, a group of users, or one or more computerresources.

pseudo terminal name . In NetView Access Services, aname used to represent a terminal in a relay mode session.If the session has ACB type Unique or Individual, this namecan be one from a pool of names, each using a commonprefix with different numbers affixed. If the session has ACBtype Shared, this name is not from a pool, but it could be thesame as the prefix, with no numbers suffixed.

pseudo terminal prefix . In NetView Access Services, astring used to define a pool of pseudo terminal names. Thenames are defined by suffixing numbers to this prefix.

RACF. Resource Access Control Facility. An IBM licensedprogram that provides for access control by identifying andverifying users to the system, authorizing access to protectedresources, logging the detected unauthorized attempts toenter the system, and logging the detected accesses to pro-tected resources.

recording . The process of storing a sequence of data forfuture use in a logon profile.

relay mode . The mode you use when all processing of anapplication goes via NetView Access Services.

returning . In NetView Access Services, the process ofusing a special key or command, when in an application, todisplay the Application Selection panel on the screen, withoutlogging off or disconnecting from that application.

second-level help . In NetView Access Services, help thatis displayed on a panel when the help key or command isentered twice in an input field of a NetView Access Servicespanel.

secondary logical unit . In SNA, the LU that contains thesecondary half-session for a particular LU-to-LU session.Contrast with primary logical unit. See LU.

session . In SNA, a logical connection between two networkaddressable units that can be activated, tailored to providevarious protocols, and deactivated as required. In NetViewAccess Services, a session between NetView Access Ser-vices and an application.

98 NetView Access Services Version 2 Messages

Page 111: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

single access control . A facility that provides for pro-grammed control, from a single screen, of a user’s authori-zation to access-protected data.

SLU. Secondary LU.

SNA. System Network Architecture. The description of thelogical structure, formats, protocols, and operationalsequences for transmitting information units through, andcontrolling the configuration and operation of, networks.

SNA network . In SNA, the part of a user-applicationnetwork that conforms to the formats and protocols ofSystem Network Architecture. It enables reliable transfer ofdata among users, and provides protocols for controlling theresources of various network configurations.

system . In data processing, a collection of people,machines, and methods organized to accomplish a set ofspecific functions.

system administrator . In NetView Access Services, anadministrator of the system.

system-internal name . The name by which an applicationis identified to the NetView Access Services system. The

same application may have a different name within eachgroup.

TPN. Transaction Program Name. In NetView Access Ser-vices, the name of the transaction program for ASR-to-ASRcommunication.

TSO. Time Sharing Option.

user exit . A point in an IBM-supplied program at which auser exit routine may be given control.

user exit routine . A routine written by a user to take controlat a user exit of a program supplied by IBM.

variable . A name used to represent a data item whosevalue can be changed while the program is running.

VTAM. Virtual Telecommunications Access Method. Its fullname is Advanced Telecommunications Function for theVirtual Telecommunications Access Method. A set of pro-grams that maintain the control of the communicationbetween terminals and application programs running undersome operating systems.

Glossary 99

Page 112: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

100 NetView Access Services Version 2 Messages

Page 113: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

Bibliography

The following books belong to the NetView Access ServicesVersion 2 library:

NetView Access Services Version 2 General Information,GH19-4497

NetView Access Services Version 2 User’s Guide,SH19-4499

NetView Access Services Version 2 Administration,SH19-4500

NetView Access Services Version 2 Operation, SH19-4501

NetView Access Services Version 2 Customization,SH19-4502

The following are network-related publications:

SNA Application Monitor General Information Manual,GH12-5160

Network Program Products—Planning, SC23-0110

Virtual Machine/System Product Group Control SystemCommand and Macro Reference, SC24-5250

Supervisor Services and Macro Instructions, GC28-1154

3274 Control Unit Description and Programmer’s Guide,GA23-0061

3270 Information Display System Data Stream Programmer’sRefeference, GA23-0059

VTAM: Programming, SC23-0115

VTAM: Messages and Codes, SC31-6405

NetView Performance Monitor Installation and Customization,SH20-6361.

Copyright IBM Corp. 1987, 1997 101

Page 114: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

Communicating Your Comments to IBM

NetView Access Services (MVS/ESA)MessagesVersion 2 Release 1

Publication No. SH19-4503-00

If you especially like or dislike anything about this book, please use one of the methods listed below to send your comments toIBM. Whichever method you choose, make sure you send your name, address, and telephone number if you would like areply.

Feel free to comment on specific errors or omissions, accuracy, organization, subject matter, or completeness of this book.However, the comments you send should pertain to only the information in this manual and the way in which the information ispresented. To request additional publications, or to ask questions or make comments about the functions of IBM products orsystems, you should talk to your IBM representative or to your IBM authorized remarketer.

When you send comments to IBM, you grant IBM a nonexclusive right to use or distribute your comments in any way itbelieves appropriate without incurring any obligation to you.

If you are mailing a readers' comment form (RCF) from a country other than the United States, you can give the RCF to thelocal IBM branch office or IBM representative for postage-paid mailing.

� If you prefer to send comments by mail, use the RCF at the back of this book.

� If you prefer to send comments by FAX, use this number:

39+6+5966+2077

Make sure to include the following in your note:

� Title and publication number of this book� Page number or topic to which your comment applies.

Page 115: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

Help Us Help You!

NetView Access Services (MVS/ESA)MessagesVersion 2 Release 1

Publication No. SH19-4503-00

We hope you find this publication useful, readable and technically accurate, but only you can tell us! Your comments andsuggestions will help us improve our technical publications. Please take a few minutes to let us know what you think bycompleting this form.

Specific Comments or Problems:

Please tell us how we can improve this book:

Thank you for your response. When you send information to IBM, you grant IBM the right to use or distribute the informationwithout incurring any obligation to you. You of course retain the right to use the information in any way you choose.

Name Address

Company or Organization

Phone No.

Overall, how satisfied are you with the information in this book? Satisfied Dissatisfied

Ø Ø

How satisfied are you that the information in this book is: Satisfied Dissatisfied

Accurate Ø ØComplete Ø ØEasy to find Ø ØEasy to understand Ø ØWell organized Ø ØApplicable to your task Ø Ø

Page 116: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

Cut or FoldAlong Line

Cut or FoldAlong Line

Help Us Help You !SH19-4503-00 IBM

Fold and Tape Please do not staple Fold and Tape

PLACEPOSTAGESTAMPHERE

NetView Access Services Information DevelopmentRome Tivoli LaboratoryIBM Italia S.p.A.Via Sciangai, 5300144 RomeItaly

Fold and Tape Please do not staple Fold and Tape

SH19-4503-00

Page 117: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages
Page 118: Messages - IBMpublib.boulder.ibm.com/tividd/td/job/SH19-4503-00/en_US/...Access Services messages. NetView Access Services Version 2 Messages

IBM

Program Number: 5695-036

Printed in Denmark by IBM Danmark A/S

SH19-45ð3-ðð