mach high efficiency boilers

40
1 Innovation & Leadership Innovation & Leadership Since 1880 Since 1880 Technical Support Technical Support Services Services

Upload: dvarrone

Post on 19-May-2015

515 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: Mach High Efficiency Boilers

1

Innovation & LeadershipInnovation & LeadershipSince 1880Since 1880

Technical Support Technical Support ServicesServices

Page 2: Mach High Efficiency Boilers

2

MACHSeries

Page 3: Mach High Efficiency Boilers

3

Page 4: Mach High Efficiency Boilers

4

Page 5: Mach High Efficiency Boilers

5

Digital PID Control...

Page 6: Mach High Efficiency Boilers

6

Electronic Air Volume Regulation...

Page 7: Mach High Efficiency Boilers

7

Precision Fuel-Air Ratio Controller...

…excellent repeatability

Page 8: Mach High Efficiency Boilers

8

Page 9: Mach High Efficiency Boilers

9

Page 10: Mach High Efficiency Boilers

10

Page 11: Mach High Efficiency Boilers

11

So What ?So What ?

Why does this Why does this boilerboiler

save so much save so much money?money?

Page 12: Mach High Efficiency Boilers

12

Two essential Two essential factors…factors…

•The capabilities of The capabilities of the boilerthe boiler

•Proper application Proper application of the boilerof the boiler

Page 13: Mach High Efficiency Boilers

13

Unprecedented Unprecedented CapabilitiesCapabilities•Whisper quietWhisper quiet

•92% efficiency 92% efficiency •99% efficiency 99% efficiency possiblepossible•Aluminum alloy Aluminum alloy metallurgymetallurgy•Cast metal, sectional Cast metal, sectional constructionconstruction•No push nipples or No push nipples or gasketsgaskets•Designed for full Designed for full condensing servicecondensing service•Any temperature 70Any temperature 70oo to 200to 200ooFF

Page 14: Mach High Efficiency Boilers

14

Superior Fuel UtilizationSuperior Fuel Utilization

•Full modulation burnerFull modulation burner•5:1 turndown5:1 turndown•Variable speed Variable speed combustion air fancombustion air fan•Zero offset fuel-air ratio Zero offset fuel-air ratio controlcontrol•Fuel flow automatically Fuel flow automatically tracks air flowtracks air flow•Automatic air density Automatic air density compensationcompensation

•Low OLow O22 / CO / NO / CO / NOxx standardstandard

Page 15: Mach High Efficiency Boilers

15

Superior Application Superior Application VersatilityVersatility

•Small diameter ventingSmall diameter venting•Positive pressure Positive pressure ventingventing•100 equivalent ft. x 2100 equivalent ft. x 2•0.22” w.c. x 2 = 0.44” 0.22” w.c. x 2 = 0.44” w.c.w.c.•Multiple venting Multiple venting arrangementsarrangements•Extremely low electrical Extremely low electrical consumptionconsumption•Certified at 3.5” w.c. gas Certified at 3.5” w.c. gas pressurepressure

Page 16: Mach High Efficiency Boilers

16

Superior Control Superior Control CapabilityCapability•Microprocessor based Microprocessor based

integratedintegratedburner management & burner management & operating control (black operating control (black box technology)box technology)•Digital touch pad Digital touch pad interfaceinterface•Sophisticated TC Sophisticated TC algorithmsalgorithms•DHW priority capabilityDHW priority capability•Advanced monitoring & Advanced monitoring & protection algorithms protection algorithms (including freeze (including freeze protection)protection)•Multiple access levelsMultiple access levels

Page 17: Mach High Efficiency Boilers

17

Even the little stuff…Even the little stuff…

•Low water-side Low water-side pressure droppressure drop•VictaulicVictaulicTMTM connections connections•Very small footprintVery small footprint•Only 24” (61 cm) wideOnly 24” (61 cm) wide•Light weightLight weight•Available for modular Available for modular configurationconfigurationwith multi-boiler with multi-boiler modulation and modulation and sequencing control sequencing control packagespackages

Page 18: Mach High Efficiency Boilers

18

•Design certifiedDesign certified

•Factory fire-testedFactory fire-tested

•Factory authorized Factory authorized startupstartup

•Exceptional Exceptional warrantywarranty

Page 19: Mach High Efficiency Boilers

19

Peak Efficiency at Part Load…

…with smooth 5:1 turndown

Page 20: Mach High Efficiency Boilers

20

Variable flowVariable flow

Variable Variable temperaturetemperature

Low temperatureLow temperature

Full modulationFull modulation

Page 21: Mach High Efficiency Boilers

21

Innovation & LeadershipInnovation & LeadershipSince 1880Since 1880

Technical Support Technical Support ServicesServices

Page 22: Mach High Efficiency Boilers

22

What about What about systems?systems?

•IntegratingIntegrating the the boilerboiler

(understanding the system (understanding the system design issues)design issues)

•InstallingInstalling the boiler the boiler(understanding the boiler (understanding the boiler

application issues)application issues)

Page 23: Mach High Efficiency Boilers

23

Q Q ==

AA x LMTD x x LMTD x UU

Page 24: Mach High Efficiency Boilers

24

Page 25: Mach High Efficiency Boilers

25

BoilerBoiler Main Main PumpsPumps

TerminTerminal Coilsal Coils

Efficiency Efficiency DecreasesDecreases

Less Flow, Less Flow, Less KWHLess KWH

Higher Higher Temp, Temp,

Poor Part-Poor Part-Load Load

ControlControl

Efficiency Efficiency IncreasesIncreases

More More Flow, Flow, More More KWHKWH

LowerLowerTemp, Temp, Better Better

Part-Load Part-Load ControlControl

Page 26: Mach High Efficiency Boilers

26

Design IssuesDesign Issues

• Flow-temperature trade-offsFlow-temperature trade-offs

• Source-sink relationshipsSource-sink relationships

• Load profile & boiler size-Load profile & boiler size-quantity quantity

• Boiler integration strategy & Boiler integration strategy & piping designpiping design

Page 27: Mach High Efficiency Boilers

27

Page 28: Mach High Efficiency Boilers

28

Page 29: Mach High Efficiency Boilers

29

A home for the heat?A home for the heat?

Page 30: Mach High Efficiency Boilers

30

Page 31: Mach High Efficiency Boilers

31

CurrentCurrentDesign LimitsDesign Limits

• 200200ooFF

• 50 PSIG50 PSIG

• Flow rangeFlow range

Page 32: Mach High Efficiency Boilers

32

Page 33: Mach High Efficiency Boilers

33

Page 34: Mach High Efficiency Boilers

34

Page 35: Mach High Efficiency Boilers

35

Page 36: Mach High Efficiency Boilers

36

Critical IssuesCritical Issues

• Get the piping rightGet the piping right

• Get the gas supply rightGet the gas supply right

• Get the chimney rightGet the chimney right

Page 37: Mach High Efficiency Boilers

37

Venting CategoriesVenting Categories

• Category I – A non-condensing gas appliance that Category I – A non-condensing gas appliance that operates with a non-positive vent pressure.operates with a non-positive vent pressure.

• Category II – A condensing gas appliance that operates Category II – A condensing gas appliance that operates with a non-positive vent pressure.with a non-positive vent pressure.

• Category III – A non-condensing gas appliance that Category III – A non-condensing gas appliance that operates with a positive vent pressure.operates with a positive vent pressure.

• Category IV – A condensing gas appliance that operates Category IV – A condensing gas appliance that operates with a positive vent pressure.with a positive vent pressure.

Page 38: Mach High Efficiency Boilers

38

• Multiple boiler venting systems must Multiple boiler venting systems must be designed to prevent flow of be designed to prevent flow of combustion air or combustion combustion air or combustion products through off-line boilers.products through off-line boilers.

• The boiler’s vent outlet diameter may The boiler’s vent outlet diameter may or may not have anything to do with or may not have anything to do with the proper vent size.the proper vent size.

• The venting system and all of the The venting system and all of the appliances attached to it must belong appliances attached to it must belong to the same venting category.to the same venting category.

Important Chimney Sizing FactsImportant Chimney Sizing Facts

Page 39: Mach High Efficiency Boilers

39

The chimney is The chimney is an engineered an engineered system…system…

……it must be it must be engineeredengineered ! !

Page 40: Mach High Efficiency Boilers

40

Innovation & LeadershipInnovation & LeadershipSince 1880Since 1880