    Circuit Breakers Definition Mechanical switching devices capable of

    making, carrying and breaking currentsunder normal and abnormal conditions

  • 8/11/2019 LTCB 1 Maint.

    2/41

    Circuit Breakers Requirements

    Opens & closes in shortest possible time Conducts rated current.

    Withstands thermally & mechanically anyshort circuit.

    Maintains its voltage to earth across opencontacts.

    Does not create over voltages during circuitopening

    Easy to maintain. Not very expensive.

  • 8/11/2019 LTCB 1 Maint.

    3/41

    Particulars of a Circuit Breaker

    Medium for arc extinction. Rated line voltage. Rated breaking current. Type of construction e.g outdoor,

    indoor. Etc Type of operating mechanism Total breaking time.

  • 8/11/2019 LTCB 1 Maint.

    4/41

    Frequency of LTCB maint.depends upon.

    1. Service condition 2. Frequency of operation

    3.Tripping of fault 4. Relative humidity

    5. Presence of dust 6. Reactive gases

  • 8/11/2019 LTCB 1 Maint.

    5/41

    Circuit breakers Elements

    Main Contact Insulation between main contacts Interruption chamber Control, supervisory and auxiliary

    devices Insulating link between control unit and

    main contact

  • 8/11/2019 LTCB 1 Maint.

    6/41

    Circuit Breakers rating

    Rated normal current: to be carried withouttemperature rise.

    Rated breaking current: Highest current to be interrupted rms of the peak value of the Asymmetrical

    current.

  • 8/11/2019 LTCB 1 Maint.

    7/41

    Circuit Breakers rating

    Generally and according to voltage range, aconstant is used to multiply the short circuit

    current to obtain the breaking current Rated MVA = sqrt(3) * Line voltage

    (kV) * breaking current (kA)

  • 8/11/2019 LTCB 1 Maint.

    8/41

    LT CIRCUIT BREAKER PARTS

    Mechanism Manual operation Electrical operation

    Pole Main contacts Silver cadmium oxide

    Arcing contact Tungsten base alloy Arc chute

  • 8/11/2019 LTCB 1 Maint.

    9/41

    Breaker parts cont.. Cradle for draw out

    Service position Main contact + control contact Test position - Control contact Isolated position No contact

    Control box Closing and trip push botton Operating handle On Off indicator

  • 8/11/2019 LTCB 1 Maint.

    10/41

    Breaker part contd..

    Built-in-release Magneto thermal release Over laod

    Short circuit Voltmetric release

    Under voltage release Shunt release

    Remote operation External relays

  • 8/11/2019 LTCB 1 Maint.

    11/41

    Main Parts of ACB

  • 8/11/2019 LTCB 1 Maint.

    12/41

  • 8/11/2019 LTCB 1 Maint.

    13/41

  • 8/11/2019 LTCB 1 Maint.

    14/41

  • 8/11/2019 LTCB 1 Maint.

    15/41

    Breaker accessories

    Motor Auxiliary contacts- NO or NC Terminal row Micro switches

  • 8/11/2019 LTCB 1 Maint.

    16/41

    Mitsubishi ACB

  • 8/11/2019 LTCB 1 Maint.

    17/41

    ABB, ACB 1250 A

  • 8/11/2019 LTCB 1 Maint.

    18/41

    Heavy Industrial Breaker

  • 8/11/2019 LTCB 1 Maint.

    19/41

    Inside of ACB

    http://en.wikipedia.org/wiki/File:Circuitbreaker.jpg
  • 8/11/2019 LTCB 1 Maint.

    20/41

    Schneider Electric

  • 8/11/2019 LTCB 1 Maint.

    21/41

    Inside of the Breaker

  • 8/11/2019 LTCB 1 Maint.

    22/41

    Types of mainteance

    1. preventive

    2. breakdown3. Condition based

    4. Predective

  • 8/11/2019 LTCB 1 Maint.

    23/41

    INSPECTION SCHEDULE

    EVERY YEAR

    1. Visual checks

    2. Cleaning the insulating parts

    3. Check and clean the arc chute

  • 8/11/2019 LTCB 1 Maint.

    24/41

    After short circuit clearanceOr

    Every 5 yeas or 10000 operation

    1. Dismantle the breaker check the contacts

    Tightening the bus bolt clean the mechanism replace the worn out parts

  • 8/11/2019 LTCB 1 Maint.

    25/41

  • 8/11/2019 LTCB 1 Maint.

    26/41

    Greasing

    No greasing is required in dust free& non corrosion atmosphere

    Regrease the breaker after a cycleof 500 operations

  • 8/11/2019 LTCB 1 Maint.

    27/41

    Components to be greased

    1. Rubbing surfaces in the mechanism2. Pins

    3. Roller assembly

    4. Pole latch spring

    5. Slotted guide6. Crank

  • 8/11/2019 LTCB 1 Maint.

    28/41

    Recommended grades of

    grease

    LITHON 2 OF H.P BALMEROL MOLY GREASE

    ML5

  • 8/11/2019 LTCB 1 Maint.

    29/41

    Components not be greased

    All releases

    Main isolating contacts Earthing terminal Secondary isolating contacts

  • 8/11/2019 LTCB 1 Maint.

    30/41

    Important points for general

    maintenance Isolation of circuit breaker from power & control

    supply

    Discharging of spring Observe all the instruction Understand the procedure of breaker operation

    Do not use force Replace the cover and wire mesh after the inspection

  • 8/11/2019 LTCB 1 Maint.

    31/41

    Oiling /greasing after cleaning only Use always proper tools Spit pins, lock washers, spring washers

    should be replaced with new All the gaskets, o-rings & rubber washersshould be replaced with new

    Dismantled parts should be kept in safe anddry place New cloth to be used for cleaning the

    interrupter

  • 8/11/2019 LTCB 1 Maint.

    32/41

    Do check the all fixing bolts Test through slow operation

  • 8/11/2019 LTCB 1 Maint.

    33/41

    caution

    Mechanism must be dischargedbefore maint

    Draw out the breaker Breakers must be periodically

    operated

  • 8/11/2019 LTCB 1 Maint.

    34/41

    MCCB

  • 8/11/2019 LTCB 1 Maint.

    35/41

    MPCB

    Protection against over current

    Protection against short circuit Protection against earth fault Protection against single phasing

  • 8/11/2019 LTCB 1 Maint.

    36/41

    Current Range 0.1630 A

    UL Listed for Motor Loads

    Short Circuit Protection

    Overload Protection

    Visible Trip Indication High Current Limiting

    High Switching Capacity

  • 8/11/2019 LTCB 1 Maint.

    37/41

    Key Specifications/Special Features: Rated current: 0.1-0.16, 0.16-0.25, 0.25-0.4,

    0.4-0.63, 0.63-1, 1-1.6, 1.6-2.5, 2.5-4, 4-6.3,6-10, 9-14, 13-18, 17-23, 20-25, 24-32A

    Rated voltage: up to 660

    Frequency: 50/60Hz

  • 8/11/2019 LTCB 1 Maint.

    38/41

    MPCB

    http://epub1.rockwellautomation.com/images/web-proof-small/GL/36209.jpg
  • 8/11/2019 LTCB 1 Maint.

    39/41

  • 8/11/2019 LTCB 1 Maint.

    40/41

    MPCB

    http://powerli.manufacturer.globalsources.com/si/6008828230287/LargeImage/50-60Hz-Motor-Protection/product_id-1007805288/action-GetProduct.htm
  • 8/11/2019 LTCB 1 Maint.

    41/41