Localization techniques

Islam Kassem

Level 6

[email protected]

Page 2: Localization tech

Principles of Image Formation

• Ideal results:

– Sharp image

– Image of the true shape and size of the object being radiographed

[email protected]

Page 3: Localization tech

Five Fundamental Principles of Shadow Casting

• Smallest radiation source

• Target-film-distance long as practical

• Object-film-distance short as possible

• Parallel film to long axis of teeth

• Perpendicular alignment of beam to film & objects

[email protected]

Page 4: Localization tech

Paralleling Technique

• Technique of choice due to image accuracy

• Implication of name

• Developed 1920

• Requires use of long target-film-distance

– 16” PID or recessed tubehead

[email protected]

Page 5: Localization tech

Principles of the Paralleling Technique

• Film placed parallel to long axis of teeth

• Beam directed perpendicular to film & long axis of teeth

• Film holder used to keep film flat & unbent

• Long PID or TFD to offset increased magnification due to great OFD

[email protected]

Page 6: Localization tech

Principles of the Paralleling Technique

[email protected]

Page 7: Localization tech

Steps of the Paralleling Technique

• Film placement

• Film position – Vertical dimension

• Parallel to long axis

• Two-point contact

– Horizontal dimension

• Beam alignment – Vertical

– Horizontal

• Film exposure

[email protected]

Page 8: Localization tech

Steps of the Paralleling Technique

• Film placement: position film to cover

prescribed area (teeth to be examined)

[email protected]

Page 9: Localization tech

Steps of the Paralleling Technique

• Film position

– Vertical dimension: position film parallel to long axes of teeth by placing far away from lingual surfaces of teeth

[email protected]

Page 10: Localization tech

Steps of the Paralleling Technique

• Film position

– Vertical dimension: position film parallel to long axes of teeth by placing far away from lingual surfaces of teeth

– Two-point contact: maintain contact of top edge of film with palate & bite portion of holder with maxillary occlusal surfaces

[email protected]

Page 11: Localization tech

Steps of the Paralleling Technique

Radiation

beam

Two-

point

contact

Maxillary molar

[email protected]

Page 12: Localization tech

Steps of the Paralleling Technique

• Film position

– Horizontal dimension: position horizontal plane of film parallel to facial surfaces of teeth being radiographed

[email protected]

Page 13: Localization tech

Steps of the Paralleling Technique

Horizontal

position of

film

[email protected]

Page 14: Localization tech

Steps of the Paralleling Technique

• Beam alignment

– Vertical: direct radiation beam perpendicular to film & long axes of teeth

– Horizontal: direct radiation beam through the contact areas of the teeth

[email protected]

Page 15: Localization tech

Criteria of Diagnostic Acceptability

• What’s a “good” film?

– Area of interest clearly displayed

– Apical regions visible with 2-3 mm of surrounding bone

– Entire tooth/teeth length displayed

– No cone-cutting in region of interest

[email protected]

Page 16: Localization tech

Beam Alignment Devices

• XCP

– Plastic bite block or styrofoam

– Metal arm supports plastic ring

– Arm used to align horizontal & vertical beam alignment

[email protected]

Page 17: Localization tech

Beam Alignment Devices

– Ring further aligns beam & prevents cone cutting

– Cotton rolls used for stabilization

– Rectangular PID or lead collimators available

[email protected]

Page 18: Localization tech

Positioning

• Client

Film packet

[email protected]

Page 19: Localization tech

Client Positioning

• Midsaggital plane perpendicular to floor

• Maxillary occlusal plane parallel to floor for maxillary films

• Mandibular occlusal plane parallel to floor for mandibular films

[email protected]

Page 20: Localization tech

Film Packet Positioning

• Film holder – Anterior: longest

dimension of film placed vertically

– Posterior: widest dimension of film placed horizontally

– Dot in the slot

– XCP: flex backing plate to open film slot

[email protected]

Page 21: Localization tech

XCP Holders

• Assembly

• Positioning

• Step-by-step procedures

[email protected]

Page 22: Localization tech

XCP Assembly

• Insert rod into openings in bite block

• Insert indicator rod into aiming ring slot

• Check for correct assembly

[email protected]

Page 23: Localization tech

XCP Placement Into Oral Cavity

• Center film & holder behind teeth to be radiographed

• Maintain film parallel to long axis of teeth & buccal surfaces of teeth

• Stabilized bite block against occlusal surfaces of teeth to be radiographed

[email protected]

Page 24: Localization tech

Long Axes of the Teeth

Maxillary Arch

[email protected]

Page 25: Localization tech

Long Axes of the Teeth

Mandibular Arch

[email protected]

Page 26: Localization tech

Sequence of Films

• Several possibilities

• Need to remember which films have been exposed

• #1-32

• Cross arch

• Anterior first

[email protected]

Page 27: Localization tech

XCP Placement Into Oral Cavity

[email protected]

Page 28: Localization tech

XCP Placement Into Oral Cavity

• Insert cotton roll under bite block

• Instruct client to close firmly

• Slide aiming ring along indicator rod until close to client’s skin

• Expose film!

[email protected]

Page 29: Localization tech

Stabe Holder

• Film Placement

– Holder

– Oral Cavity

[email protected]

Page 30: Localization tech

Stabe Holder

• Anatomical considerations – Long axes

– Apices location

• Beam alignment/angulation – Vertical

– Horizontal

– Point of entry

– Centering exposure field

[email protected]

Page 31: Localization tech

Stabe Holder

• Design features

– Radiolucent

– Rigid back

– Disposable

– Bite stability

– Long bite portion

[email protected]

Page 32: Localization tech

Stabe Holder Film Placement

• Dot in slot

• Center film in holder

– Anterior = vertical

– Posterior = horizontal

[email protected]

Page 33: Localization tech

Stabe Holder Film Placement

• Position behind teeth of interest

• Place film parallel to long axes of teeth

• Stabilize holder against occlusal surfaces of teeth being radiographed (two-point contact)

[email protected]

Page 34: Localization tech

Stabe Holder

• Anatomical considerations

– Long axes

– Apices location

[email protected]

Page 35: Localization tech

Location of Apices

•Maxillary: A-T line

•Mandibular: One inch above inferior border of mandible

[email protected]

Page 36: Localization tech

Point of Entry

• Central/lateral: side of nose

• Canine: ala of nose

• Premolar: pupil of eye

• Molar: outer corner of eye

[email protected]

Page 37: Localization tech

Stabe Holder

• Beam alignment/angulation

– Vertical

– Horizontal

– Point of entry

– Centering exposure field

[email protected]

Page 38: Localization tech

Vertical Beam Alignment

• Two steps

– Step 1: Parallel PID with bite portion of Stabe holder

– Step 2: Position center of PID over point of entry

[email protected]

Page 39: Localization tech

Horizontal Beam Alignment

• Align face of PID parallel with film

[email protected]

Page 40: Localization tech

Center Exposure Field

• To avoid cone cut sight down one side and top or bottom of PID

[email protected]

Page 41: Localization tech

Composition of Interproximal Radiographs

• Composition

– Adult: four posterior #2 films

– Mixed dentition or deciduous: try for two #2, but four #1 are acceptable

[email protected]

Page 42: Localization tech

Interproximal Survey Pedo

•Two #1 films used

[email protected]

Page 43: Localization tech

Interproximal Survey Mixed Dentition

•Two #2 films used

[email protected]

Page 44: Localization tech

Interproximal Survey Adult Dentition

•Four #2 films used

[email protected]

Page 45: Localization tech

Interproximal Survey Adult Dentition

•Four or six #2 films used for vertical

placement

[email protected]

Page 46: Localization tech

Interproximal Survey Adult Dentition

•Two #3 long bitewing films used

[email protected]

Page 47: Localization tech

Interproximal Radiographic Technique

• Principles

– Center film behind the teeth of interest

– Place film close & parallel to teeth

– Direct radiation beam perpendicular to teeth & film

[email protected]

Page 48: Localization tech

Client Positioning for Interproximal Radiographs

• Client positioned upright

• Midsaggital plane perpendicular to floor

[email protected]

Page 49: Localization tech

Film Holders for Interproximal Radiographs

• Film placed in tab, loop or XCP holders

[email protected]

Page 50: Localization tech

Film Placement for Interproximal Radiographs Using XCP

• No specific location for dot

• Center films behind teeth of interest

[email protected]

Page 51: Localization tech

Film Placement for Interproximal Radiographs Using XCP

• Center films behind teeth of interest in vertical and horizontal position

[email protected]

Page 52: Localization tech

Premolar Film Placement Using XCP

• Center films behind teeth of interest in horizontal position

• Maintain film parallel to buccal surfaces of premolars

Plane of buccal surfaces of premolars

[email protected]

Page 53: Localization tech

Premolar Film Placement With XCP

[email protected]

Page 54: Localization tech

Premolar Film Placement With XCP

[email protected]

Page 55: Localization tech

Premolar Film Placement With XCP

[email protected]

Page 56: Localization tech

Diagnostic Premolar Radiograph

[email protected]

Page 57: Localization tech

Molar Film Placement Using XCP

• Center films behind teeth of interest in horizontal position

• Maintain film parallel to buccal surfaces of molars

Plane of buccal surfaces of premolars

[email protected]

Page 58: Localization tech

Molar Film Placement With XCP

[email protected]

Page 59: Localization tech

Molar Film Placement With XCP

[email protected]

Page 60: Localization tech

Molar Film Placement With XCP

[email protected]

Page 61: Localization tech

Molar Film Placement With XCP

[email protected]

Page 62: Localization tech

Vertical Bitewings

• Indicated to examine alveolar bone levels in moderate to advanced periodontal disease

• Four to six films exposed depending on the number of erupted molars

[email protected]

Page 63: Localization tech

Nondiagnostic Interproximal Radiographs

[email protected]

Page 64: Localization tech

Criteria for Diagnostic Acceptability

• What makes a “good” interproximal radiograph?

– Teeth of interest visible in the film

– Crowns & proximal surfaces of teeth of interest are visible without overlap of contact areas

– Alveolar crestal bone is visible surrounding teeth of interest

[email protected]

Page 65: Localization tech

Criteria for Diagnostic Acceptability

[email protected]

Page 66: Localization tech

Client Positioning for Interproximal Radiographs Using Loops/Tabs

• Client positioned upright

• Midsaggital plane perpendicular to floor

• Occlusal plane parallel to floor

[email protected]

Page 67: Localization tech

Film Placement for Interproximal Radiographs Using Loops/Tabs

• Slide film into paper loop or place stick-on-tab across center of film

[email protected]

Page 68: Localization tech

Film Placement for Interproximal Radiographs Using Loops/Tabs

• No specific location for dot

• Center films behind teeth of interest

[email protected]

Page 69: Localization tech

Film Placement for Interproximal Radiographs Using Loops/Tabs

• Fold tab upward against film

• Hold film between thumb & index finger

• Insert into oral cavity

• Place lower half of film between tongue & teeth

• Turn tab downward & hold against occlusal surfaces of the mandibular teeth

[email protected]

Page 70: Localization tech

Film Placement for Interproximal Radiographs Using Loops/Tabs

[email protected]

Page 71: Localization tech

Beam Alignment for Interproximal Radiographs Using Loops/Tabs

• Vertical angulation: (Up/down plane)

– May be positive or negative

– Measured in degrees on outside of tubehead

– Positive vertical angulation: PID above occlusal plane & beam directed toward floor

– Negative vertical angulation: PID below occlusal plane & beam directed toward ceiling

[email protected]

Page 72: Localization tech

Beam Alignment for Interproximal Radiographs Using Loops/Tabs

Vertical Angulation

[email protected]

Page 73: Localization tech

Beam Alignment for Interproximal Radiographs Using Loops/Tabs

• Horizontal angulation: (Side-to-side plane)

– Determines appearance of proximal teeth surfaces

[email protected]

Page 74: Localization tech

Beam Alignment for Interproximal Radiographs Using Loops/Tabs

–Direct radiation perpendicular to curvature of arch and through contact areas of teeth

[email protected]

Page 75: Localization tech

Premolar Interproximal Using Loops/Tabs

•Insert film packet into oral cavity between tongue and premolars

•Position film far enough forward to include distal half of canines

[email protected]

Page 76: Localization tech

Premolar Interproximal Using Loops/Tabs

• Center films behind teeth of interest in vertical position

[email protected]

Page 77: Localization tech

Premolar Interproximal Using Loops/Tabs

• Center films behind teeth of interest in horizontal position

• Maintain film parallel to buccal surfaces of premolars

Plane of buccal surfaces of premolars

[email protected]

Page 78: Localization tech

Vertical Beam Alignment for Premolar Interproximal Radiograph

• Adjust vertical angulation to + 10 degrees

[email protected]

Page 79: Localization tech

Vertical Beam Alignment for Premolar Interproximal Radiograph

[email protected]

Page 80: Localization tech

Vertical Beam Alignment for Premolar Interproximal Radiograph

•Direct PID at occlusal plane

[email protected]

Page 81: Localization tech

Horizontal Beam Alignment for Premolar Interproximal Radiograph

Align open end of PID with buccal surfaces of premolar teeth

[email protected]

Page 82: Localization tech

Centering Exposure for Premolar Interproximal Radiograph

•Make sure that PID covers max. & mand canines to avoid cone-cutting

[email protected]

Page 83: Localization tech

Diagnostic Premolar Interproximal Radiograph

[email protected]

Page 84: Localization tech

Molar Interproximal Using Loops/Tabs

•Insert film packet into oral cavity between tongue and molars

•Position film far enough back to include the distal of the most posteriorly erupted molar

[email protected]

Page 85: Localization tech

Molar Interproximal Using Loops/Tabs

• Center films behind teeth of interest in vertical position

[email protected]

Page 86: Localization tech

Molar Interproximal Using Loops/Tabs

• Center films behind teeth of interest in horizontal position

• Maintain film parallel to buccal surfaces of molars

Plane of buccal surfaces of premolars

[email protected]

Page 87: Localization tech

Vertical Beam Alignment for Molar Interproximal Radiograph

• Adjust vertical angulation to + 10 degrees

[email protected]

Page 88: Localization tech

Vertical Beam Alignment for Molar Interproximal Radiograph

[email protected]

Page 89: Localization tech

Vertical Beam Alignment for Molar Interproximal Radiograph

•Direct PID at occlusal plane

[email protected]

Page 90: Localization tech

Horizontal Beam Alignment for Molar Interproximal Radiograph

Align open end of PID with buccal surfaces of molar teeth

[email protected]

Page 91: Localization tech

Horizontal Beam Alignment for Molar Interproximal Radiograph

[email protected]

Page 92: Localization tech

Centering Exposure for Molar Interproximal Radiograph

•Make sure that PID covers max. & mand second premolars to avoid cone-cutting

[email protected]

Page 93: Localization tech

Diagnostic Molar Interproximal Radiograph

[email protected]

Page 94: Localization tech

Vertical Bitewings with Loops/Tabs

• Indicated to examine alveolar bone levels in moderate to advanced periodontal disease

• Four to six films exposed depending on the number of erupted molars

[email protected]

Page 95: Localization tech

Vertical Bitewings with Loops/Tabs

Vertical beam alignment = plus 15 degrees

Horizontal beam alignment = the same as for horizontal interproximals

[email protected]

Page 96: Localization tech

Nondiagnostic Interproximal Radiographs

• Incorrect (negative) vertical angulation

[email protected]

Page 97: Localization tech

Nondiagnostic Interproximal Radiographs

[email protected]

Page 98: Localization tech

Criteria for Diagnostic Acceptability

• What makes a “good” interproximal radiograph?

– Teeth of interest visible in the film

– Crowns & proximal surfaces of teeth of interest are visible without overlap of contact areas

– Alveolar crestal bone is visible surrounding teeth of interest

[email protected]

Page 99: Localization tech

Criteria for Diagnostic Acceptability

[email protected]

Page 100: Localization tech