load cell catalogue - newresistance.it · load cell catalogue. prcsn rsstrs single point load cells...

50
PRECISION RESISTORS Via Garibaldi, 21 - 20092 Cinisello Balsamo (MI) - Telefono: 02 61.27.759 - Fax: 02 61.28.449 www.newresistance.it Load Cell Catalogue

Upload: lytram

Post on 18-May-2018

301 views

Category:

Documents


11 download

TRANSCRIPT

Page 1: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

Via Garibaldi, 21 - 20092 Cinisello Balsamo (MI) - Telefono: 02 61.27.759 - Fax: 02 61.28.449www.newresistance.it

Load Cell Catalogue

Page 2: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

Single Point Load Cells Shear Beam Load Cells

S-Type Load Cells

Planar Beam Load Cells

Miniature Load Cells

Force Load Cells

Page 3: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it2

TB201 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TB201 Specification:

Capacity 3, 6, 10, 15, 20, 30, 40, 50 (Kg)

Accuracy C4-C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮4mm*400mm

Hysteresis Error ±0.01%F.S. Protection Class IP66

Input Resistance 405±10Ω Wiring Code:

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Scale and Weighing Scales, etc.

* Max. Platform Size: 250×350mm

TEKO®

www.TekoChina.com Document Number: B201Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

TB201 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TB201 Specification:

Capacity 3, 6, 10, 15, 20, 30, 40, 50 (Kg)

Accuracy C4-C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮4mm*400mm

Hysteresis Error ±0.01%F.S. Protection Class IP66

Input Resistance 405±10Ω Wiring Code:

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Scale and Weighing Scales, etc.

* Max. Platform Size: 250×350mm

TEKO®

www.TekoChina.com Document Number: B201Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

TB201 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TB201 Specification:

Capacity 3, 6, 10, 15, 20, 30, 40, 50 (Kg)

Accuracy C4-C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮4mm*400mm

Hysteresis Error ±0.01%F.S. Protection Class IP66

Input Resistance 405±10Ω Wiring Code:

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Scale and Weighing Scales, etc.

* Max. Platform Size: 250×350mm

TEKO®

www.TekoChina.com Document Number: B201Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

NRB201 (Single Point Load Cell)

NRB201 Specification:

Page 4: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it3

NRB202 (Single Point Load Cell)

TB202 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TB202 Specification:

Capacity 3, 6, 10, 15, 20, 30, 40, 50 (Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮4mm*400mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code:

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: B202Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

Scale and Weighing Scales, etc.

* Max. Platform Size: 250×350mm

TB202 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TB202 Specification:

Capacity 3, 6, 10, 15, 20, 30, 40, 50 (Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮4mm*400mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code:

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: B202Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

Scale and Weighing Scales, etc.

* Max. Platform Size: 250×350mm

TB202 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TB202 Specification:

Capacity 3, 6, 10, 15, 20, 30, 40, 50 (Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮4mm*400mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code:

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: B202Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

Scale and Weighing Scales, etc.

* Max. Platform Size: 250×350mm

NRB202 Specification:

Page 5: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it4

TB203 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TB203 Specification:

Capacity 20, 30, 40, 50, 60, 100(Kg)

Accuracy C4 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮4mm*400mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* High Accuracy

Scale and Weighing Scales, etc.

* Max. Platform Size: 250×350mm

TEKO®

www.TekoChina.com Document Number: B203Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

4

TB203 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TB203 Specification:

Capacity 20, 30, 40, 50, 60, 100(Kg)

Accuracy C4 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮4mm*400mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* High Accuracy

Scale and Weighing Scales, etc.

* Max. Platform Size: 250×350mm

TEKO®

www.TekoChina.com Document Number: B203Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

4

NRB203 (Single Point Load Cell)TB203 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TB203 Specification:

Capacity 20, 30, 40, 50, 60, 100(Kg)

Accuracy C4 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮4mm*400mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* High Accuracy

Scale and Weighing Scales, etc.

* Max. Platform Size: 250×350mm

TEKO®

www.TekoChina.com Document Number: B203Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

4

NRB203 Specification:

Page 6: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it5

TB206 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TB206 Specification:

Capacity 20, 30, 40, 50, 60, 100(Kg)

Accuracy C4 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮4mm*400mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* High Accuracy

Scale and Weighing Scales, etc.

* Max. Platform Size: 250×350mm

TEKO®

* With Overload Protection

www.TekoChina.com Document Number: B206Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

5

TB206 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TB206 Specification:

Capacity 20, 30, 40, 50, 60, 100(Kg)

Accuracy C4 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮4mm*400mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* High Accuracy

Scale and Weighing Scales, etc.

* Max. Platform Size: 250×350mm

TEKO®

* With Overload Protection

www.TekoChina.com Document Number: B206Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

5

TB206 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TB206 Specification:

Capacity 20, 30, 40, 50, 60, 100(Kg)

Accuracy C4 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮4mm*400mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* High Accuracy

Scale and Weighing Scales, etc.

* Max. Platform Size: 250×350mm

TEKO®

* With Overload Protection

www.TekoChina.com Document Number: B206Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

5

TB206 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TB206 Specification:

Capacity 20, 30, 40, 50, 60, 100(Kg)

Accuracy C4 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮4mm*400mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* High Accuracy

Scale and Weighing Scales, etc.

* Max. Platform Size: 250×350mm

TEKO®

* With Overload Protection

www.TekoChina.com Document Number: B206Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

5

NRB206 (Single Point Load Cell)

NRB206 Specification:

Page 7: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it6

TB207 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TB207 Specification:

Capacity 20, 40, 60, 100, 200 (Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.028%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮4mm*400mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: B207Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

Scale and Weighing Scales, etc.

* Max. Platform Size: 250×350mm

6

TB207 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TB207 Specification:

Capacity 20, 40, 60, 100, 200 (Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.028%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮4mm*400mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: B207Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

Scale and Weighing Scales, etc.

* Max. Platform Size: 250×350mm

6

TB207 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TB207 Specification:

Capacity 20, 40, 60, 100, 200 (Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.028%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮4mm*400mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: B207Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

Scale and Weighing Scales, etc.

* Max. Platform Size: 250×350mm

6

NRB207 (Single Point Load Cell)

NRB207 Specification:

Page 8: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it7

TD301 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TD301 Specification:

Capacity 25, 40, 60, 100, 200, 350(Kg)

Accuracy C3-C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*1500mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* High Accuracy

Scale and Weighing Scales, etc.

* Max. Platform Size: 400×400mm

TEKO®

www.TekoChina.com Document Number: D301Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

7

TD301 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TD301 Specification:

Capacity 25, 40, 60, 100, 200, 350(Kg)

Accuracy C3-C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*1500mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* High Accuracy

Scale and Weighing Scales, etc.

* Max. Platform Size: 400×400mm

TEKO®

www.TekoChina.com Document Number: D301Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

7

NRD301 (Single Point Load Cell)TD301 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TD301 Specification:

Capacity 25, 40, 60, 100, 200, 350(Kg)

Accuracy C3-C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*1500mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* High Accuracy

Scale and Weighing Scales, etc.

* Max. Platform Size: 400×400mm

TEKO®

www.TekoChina.com Document Number: D301Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

7

NRD301 Specification:

Page 9: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it8

TD302 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TD302 Specification:

Capacity 60, 100, 200, 350, 500(Kg)

Accuracy C3-C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*1500mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Scale and Weighing Scales, etc.

* Max. Platform Size: 400×400mm

TEKO®

www.TekoChina.com Document Number: D302Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

8

TD302 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TD302 Specification:

Capacity 60, 100, 200, 350, 500(Kg)

Accuracy C3-C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*1500mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Scale and Weighing Scales, etc.

* Max. Platform Size: 400×400mm

TEKO®

www.TekoChina.com Document Number: D302Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

8

TD302 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TD302 Specification:

Capacity 60, 100, 200, 350, 500(Kg)

Accuracy C3-C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*1500mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Scale and Weighing Scales, etc.

* Max. Platform Size: 400×400mm

TEKO®

www.TekoChina.com Document Number: D302Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

8

NRD302 (Single Point Load Cell)

NRD302 Specification:

Page 10: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it9

TD303 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TD303 Specification:

Capacity 15, 20, 30, 50, ,100, 200(Kg)

Accuracy C3-C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*1500mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Scale and Platform Scales, etc.

* Max. Platform Size: 400×400mm

TEKO®

www.TekoChina.com Document Number: D303Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

9

TD303 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TD303 Specification:

Capacity 15, 20, 30, 50, ,100, 200(Kg)

Accuracy C3-C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*1500mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Scale and Platform Scales, etc.

* Max. Platform Size: 400×400mm

TEKO®

www.TekoChina.com Document Number: D303Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

9

NRD303 (Single Point Load Cell)TD303 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TD303 Specification:

Capacity 15, 20, 30, 50, ,100, 200(Kg)

Accuracy C3-C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*1500mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Scale and Platform Scales, etc.

* Max. Platform Size: 400×400mm

TEKO®

www.TekoChina.com Document Number: D303Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

9

NRD303 Specification:

Page 11: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it10

TD304 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TD304 Specification:

Capacity 25, 40, 60 100, 200(Kg)

Accuracy C3-C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*1500mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Imput Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: D304Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

Scale and Platform Scales, etc.

* Max. Platform Size: 400×400mm

10

TD304 (Single Point Load Cell)

* Used in Price Computing Scales, Counting

RoHS

TD304 Specification:

Capacity 25, 40, 60 100, 200(Kg)

Accuracy C3-C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*1500mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Imput Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: D304Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

Scale and Platform Scales, etc.

* Max. Platform Size: 400×400mm

10

NRD304 (Single Point Load Cell)

NRD304 Specification:

Page 12: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it11

TD321 (Single Point Load Cell)

* Used in Platform Scale, Counting

* Max. Platform Size: 800×800mm

RoHS

TD321 Specification:

Capacity 60, 100, 200, 300, 500, 600, 800, 1000(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*2000mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* High Accuracy

Scale, etc.

TEKO®

www.TekoChina.com Document Number: D321Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

11

TD321 (Single Point Load Cell)

* Used in Platform Scale, Counting

* Max. Platform Size: 800×800mm

RoHS

TD321 Specification:

Capacity 60, 100, 200, 300, 500, 600, 800, 1000(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*2000mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* High Accuracy

Scale, etc.

TEKO®

www.TekoChina.com Document Number: D321Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

11

TD321 (Single Point Load Cell)

* Used in Platform Scale, Counting

* Max. Platform Size: 800×800mm

RoHS

TD321 Specification:

Capacity 60, 100, 200, 300, 500, 600, 800, 1000(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*2000mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* High Accuracy

Scale, etc.

TEKO®

www.TekoChina.com Document Number: D321Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

11

TD321 (Single Point Load Cell)

* Used in Platform Scale, Counting

* Max. Platform Size: 800×800mm

RoHS

TD321 Specification:

Capacity 60, 100, 200, 300, 500, 600, 800, 1000(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*2000mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* High Accuracy

Scale, etc.

TEKO®

www.TekoChina.com Document Number: D321Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

11

NRD321 (Single Point Load Cell)

NRD321 Specification:

Page 13: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it12

TD322 (Single Point Load Cell)

* Used in Platform Scale, Counting

RoHS

TD322 Specification:

Capacity 100, 200, 300, 500, 800(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*2000mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* High Accuracy

Scale, etc.

* Max. Platform Size: 800×800mm

TEKO®

www.TekoChina.com Document Number: D322Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

12

TD322 (Single Point Load Cell)

* Used in Platform Scale, Counting

RoHS

TD322 Specification:

Capacity 100, 200, 300, 500, 800(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*2000mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* High Accuracy

Scale, etc.

* Max. Platform Size: 800×800mm

TEKO®

www.TekoChina.com Document Number: D322Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

12

TD322 (Single Point Load Cell)

* Used in Platform Scale, Counting

RoHS

TD322 Specification:

Capacity 100, 200, 300, 500, 800(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*2000mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* High Accuracy

Scale, etc.

* Max. Platform Size: 800×800mm

TEKO®

www.TekoChina.com Document Number: D322Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

12

NRD322 (Single Point Load Cell)

NRD322 Specification:

Page 14: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it13

TD326 (Single Point Load Cell)

* Used in Platform Scale, and other weighing

RoHS

TD326 Specification:

Capacity 100, 200, 300, 500, 635, 800, 1000, 1500(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*2000mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: D326

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

applications, etc.* With overload protection screw.

TEKO®

* Max. Platform Size: 1000×1000mm

13

TD326 (Single Point Load Cell)

* Used in Platform Scale, and other weighing

RoHS

TD326 Specification:

Capacity 100, 200, 300, 500, 635, 800, 1000, 1500(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮5mm*2000mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: D326

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

applications, etc.* With overload protection screw.

TEKO®

* Max. Platform Size: 1000×1000mm

13

NRD326 (Single Point Load Cell)

NRD326 Specification:

Page 15: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it14

TD326A (Single Point Load Cell)

* Used in Platform Scale, and other weighing

RoHS

TD326A Specification:

Capacity 100, 200, 300, 500, 635, 800, 1000, 1500(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮6mm*2000mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.Document Number: D326A

TEKO®

* Max. Platform Size: 1000×1000mm

www.TekoChina.comDocument Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* 6-wire Cable

applications, etc.* With overload protection screw.

14

NRD326A (Single Point Load Cell)

NRD326A Specification:

Page 16: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it15

TK401 (Single Point Load Cell)

* Used in Electronic Balance, Counting

RoHS

TK401 Specification:

Capacity 0.3, 0.6, 1, 1.5, 3(Kg)

Accuracy C3, C4, C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.015%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮4mm*250mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Max. Platform Size: 150×150mm

TEKO®

www.TekoChina.com Document Number: K401Document Version: 2007B

Features:

[email protected]

* Comply with OIML R60 Standard

* Aluminum Alloy Construction

* High Accuracy

Scale, etc.

15

TK401 (Single Point Load Cell)

* Used in Electronic Balance, Counting

RoHS

TK401 Specification:

Capacity 0.3, 0.6, 1, 1.5, 3(Kg)

Accuracy C3, C4, C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.015%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮4mm*250mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Max. Platform Size: 150×150mm

TEKO®

www.TekoChina.com Document Number: K401Document Version: 2007B

Features:

[email protected]

* Comply with OIML R60 Standard

* Aluminum Alloy Construction

* High Accuracy

Scale, etc.

15

NRK401 (Single Point Load Cell)

NRK401 Specification:

Page 17: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it16

TK402 (Single Point Load Cell)

* Used in Electronic Balance, Counting

* Max. Platform Size: 150×150mm

RoHS

TK402 Specification:

Capacity 0.3, 0.5, 1, 2, 3(Kg)

Accuracy C3, C4, C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.3±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.01%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮4mm*250mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: K402

Document Version: 2007B

Features:

[email protected]

* Comply with OIML R60 Standard

* Aluminum Alloy Construction

* High Accuracy

Scale, etc.

TEKO®

16

TK402 (Single Point Load Cell)

* Used in Electronic Balance, Counting

* Max. Platform Size: 150×150mm

RoHS

TK402 Specification:

Capacity 0.3, 0.5, 1, 2, 3(Kg)

Accuracy C3, C4, C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.3±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.01%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮4mm*250mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: K402

Document Version: 2007B

Features:

[email protected]

* Comply with OIML R60 Standard

* Aluminum Alloy Construction

* High Accuracy

Scale, etc.

TEKO®

16

NRK402 (Single Point Load Cell)

NRK402 Specification:

Page 18: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it17

TK403 (Single Point Load Cell)

* Used in Electronic Balance, Counting

RoHS

TK403 Specification:

Capacity 0.3, 0.6, 1, 1.5, 3(Kg)

Accuracy C3, C4, C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.15%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮4mm*250mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Max. Platform Size: 150×150mm

TEKO®

www.TekoChina.com Document Nember: K403Document Version: 2007B

Features:

[email protected]

* Comply with OIML R60 Standard

* Aluminum Alloy Construction

* High Accuracy

Scale, etc.

17

TK403 (Single Point Load Cell)

* Used in Electronic Balance, Counting

RoHS

TK403 Specification:

Capacity 0.3, 0.6, 1, 1.5, 3(Kg)

Accuracy C3, C4, C5 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.15%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮4mm*250mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 405±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Max. Platform Size: 150×150mm

TEKO®

www.TekoChina.com Document Nember: K403Document Version: 2007B

Features:

[email protected]

* Comply with OIML R60 Standard

* Aluminum Alloy Construction

* High Accuracy

Scale, etc.

17

NRK403 (Single Point Load Cell)

NRK403 Specification:

Page 19: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it18

TK406 (Single Point Load Cell)

* Used in Electronic Balance, Counting

RoHS

TK406 Specification:

Capacity 0.3, 0.5 1.5, 3, 6(Kg)

Accuracy C3, C4 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮0.8mm*200mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 395±10Ω Wiring Code (4-color wires):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* High Accuracy

Scale , etc.

* Max. Platform Size: 150×150mm

TEKO®

www.TekoChina.com Document Number: K406Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

18

TK406 (Single Point Load Cell)

* Used in Electronic Balance, Counting

RoHS

TK406 Specification:

Capacity 0.3, 0.5 1.5, 3, 6(Kg)

Accuracy C3, C4 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.01%F.S. Cable Length ∮0.8mm*200mm

Hysteresis Error ±0.01%F.S. Protection Class IP65

Input Resistance 395±10Ω Wiring Code (4-color wires):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* High Accuracy

Scale , etc.

* Max. Platform Size: 150×150mm

TEKO®

www.TekoChina.com Document Number: K406Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

18

NRK406 (Single Point Load Cell)

NRK406 Specification:

Page 20: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it19

TK407 (Single Point Load Cell)

* Used in Electronic Balance, Counting

Scale , etc.

RoHS

TK407 Specification:

Capacity 1.5, 2, 3, 6(Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮4mm*200mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±1.5%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Max. Platform Size: 150×150mm

TEKO®

www.TekoChina.com Document Number: K407Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

19

TK407 (Single Point Load Cell)

* Used in Electronic Balance, Counting

Scale , etc.

RoHS

TK407 Specification:

Capacity 1.5, 2, 3, 6(Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.015%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮4mm*200mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±1.5%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Max. Platform Size: 150×150mm

TEKO®

www.TekoChina.com Document Number: K407Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

19

NRK407 (Single Point Load Cell)

NRK407 Specification:

Page 21: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it20

TP350 (Single Point Load Cell)

* Used in Platform Scale, Counting

RoHS

TP350 Specification:

Capacity 10, 15, 25, 50(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.25%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮3mm*3000mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 385±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: P350

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Stainless Steel Construction

* Humidity-proof, Overload protection.

Scale, Packing Applications, etc.

* Max. Platform Size: 200×200mm

TEKO®

20

TP350 (Single Point Load Cell)

* Used in Platform Scale, Counting

RoHS

TP350 Specification:

Capacity 10, 15, 25, 50(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.25%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮3mm*3000mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 385±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: P350

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Stainless Steel Construction

* Humidity-proof, Overload protection.

Scale, Packing Applications, etc.

* Max. Platform Size: 200×200mm

TEKO®

20

TP350 (Single Point Load Cell)

* Used in Platform Scale, Counting

RoHS

TP350 Specification:

Capacity 10, 15, 25, 50(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.25%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮3mm*3000mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 385±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: P350

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Stainless Steel Construction

* Humidity-proof, Overload protection.

Scale, Packing Applications, etc.

* Max. Platform Size: 200×200mm

TEKO®

20

NRP350 (Single Point Load Cell)

NRP350 Specification:

Page 22: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it21

TP351 (Single Point Load Cell)

* Used in Platform Scale, Counting

RoHS

TP351 Specification:

Capacity 25, 50, 75, 100, 250(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.25%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮3mm*3000mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 385±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Scale, Packing Applications, etc.

* Max. Platform Size: 400×400mm

TEKO®

www.TekoChina.com Document Number: P351Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Stainless Steel Construction

* Humidity-proof, Overload protection.

21

TP351 (Single Point Load Cell)

* Used in Platform Scale, Counting

RoHS

TP351 Specification:

Capacity 25, 50, 75, 100, 250(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.25%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮3mm*3000mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 385±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Scale, Packing Applications, etc.

* Max. Platform Size: 400×400mm

TEKO®

www.TekoChina.com Document Number: P351Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Stainless Steel Construction

* Humidity-proof, Overload protection.

21

TP351 (Single Point Load Cell)

* Used in Platform Scale, Counting

RoHS

TP351 Specification:

Capacity 25, 50, 75, 100, 250(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.25%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮3mm*3000mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 385±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Scale, Packing Applications, etc.

* Max. Platform Size: 400×400mm

TEKO®

www.TekoChina.com Document Number: P351Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Stainless Steel Construction

* Humidity-proof, Overload protection.

21

TP351 (Single Point Load Cell)

* Used in Platform Scale, Counting

RoHS

TP351 Specification:

Capacity 25, 50, 75, 100, 250(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.25%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮3mm*3000mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 385±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.03%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Scale, Packing Applications, etc.

* Max. Platform Size: 400×400mm

TEKO®

www.TekoChina.com Document Number: P351Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Stainless Steel Construction

* Humidity-proof, Overload protection.

21

NRP351 (Single Point Load Cell)

NRP351 Specification:

Page 23: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it22

TG201 (Shear Beam Load Cell)

RoHS

TG201 Specification:

Capacity 500, 1000, 2000, 3000(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 3.0±0.25%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.03%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.03%F.S. Cable Length ∮5mm*3000mm

Hysteresis Error ±0.03%F.S. Protection Class IP66

Input Resistance 385±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S.

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: G201Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Alloy Steel Construction

* Used in Platform Scales, Floor Scales, etc.

22

TG201 (Shear Beam Load Cell)

RoHS

TG201 Specification:

Capacity 500, 1000, 2000, 3000(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 3.0±0.25%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.03%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.03%F.S. Cable Length ∮5mm*3000mm

Hysteresis Error ±0.03%F.S. Protection Class IP66

Input Resistance 385±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S.

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: G201Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Alloy Steel Construction

* Used in Platform Scales, Floor Scales, etc.

22

TG201 (Shear Beam Load Cell)

RoHS

TG201 Specification:

Capacity 500, 1000, 2000, 3000(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 3.0±0.25%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.03%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.03%F.S. Cable Length ∮5mm*3000mm

Hysteresis Error ±0.03%F.S. Protection Class IP66

Input Resistance 385±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S.

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: G201Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Alloy Steel Construction

* Used in Platform Scales, Floor Scales, etc.

22

NRG201 (Shear Beam Load Cell)

NRG201 Specification:

Page 24: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it23

TG202 (Shear Beam Load Cell)

RoHS

TG202 Specification:

Capacity 5000, 8000(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.25%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.03%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.03%F.S. Cable Length ∮6mm*8000mm

Hysteresis Error ±0.03%F.S. Protection Class IP66

Input Resistance 385±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S.

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Alloy Steel Construction

* Used in Platform Scales, Floor Scales, etc.

TEKO®

www.TekoChina.com Document Number: G202Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

23

TG202 (Shear Beam Load Cell)

RoHS

TG202 Specification:

Capacity 5000, 8000(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.25%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.03%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.03%F.S. Cable Length ∮6mm*8000mm

Hysteresis Error ±0.03%F.S. Protection Class IP66

Input Resistance 385±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S.

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Alloy Steel Construction

* Used in Platform Scales, Floor Scales, etc.

TEKO®

www.TekoChina.com Document Number: G202Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

23

TG202 (Shear Beam Load Cell)

RoHS

TG202 Specification:

Capacity 5000, 8000(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.25%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.03%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.03%F.S. Cable Length ∮6mm*8000mm

Hysteresis Error ±0.03%F.S. Protection Class IP66

Input Resistance 385±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±3Ω

Temp. Effect on Sensitivity ±0.03%F.S.

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Alloy Steel Construction

* Used in Platform Scales, Floor Scales, etc.

TEKO®

www.TekoChina.com Document Number: G202Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

23

NRG202 (Shear Beam Load Cell)

NRG202 Specification:

Page 25: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it24

TS501 (S-Type Load Cell)

RoHS

TS501 Specification:

Capacity 2, 5, 10, 20, 30, 50, 100 (Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮0.8mm*500mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 395±10Ω Wiring Code (4-color wires):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* Used in Crane Scales, Tensile Application, etc.

TEKO®

www.TekoChina.com Document Number: S501Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

24

TS501 (S-Type Load Cell)

RoHS

TS501 Specification:

Capacity 2, 5, 10, 20, 30, 50, 100 (Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮0.8mm*500mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 395±10Ω Wiring Code (4-color wires):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* Used in Crane Scales, Tensile Application, etc.

TEKO®

www.TekoChina.com Document Number: S501Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

24

TS501 (S-Type Load Cell)

RoHS

TS501 Specification:

Capacity 2, 5, 10, 20, 30, 50, 100 (Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.02%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮0.8mm*500mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 395±10Ω Wiring Code (4-color wires):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Aluminum Alloy Construction

* Used in Crane Scales, Tensile Application, etc.

TEKO®

www.TekoChina.com Document Number: S501Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

24

NRS501 (S-Type Load Cell)

NRS501 Specification:

Page 26: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it25

TS502 ((S-Type Load Cell)

RoHS

TS502 Specification:

Capacity 2, 5, 10, 20, 30, 50, 100 (Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.028%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.03%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.02%F.S. Cable Length ∮5mm*2000mm

Hysteresis Error ±0.02%F.S. Protection Class IP66

Input Resistance 405±10Ω Wiring Code (4 wires, Braid Shielded, PVC Cable):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: S502

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* Used in Crane Scales, Tensile Application, etc.

TEKO®

25

TS502 ((S-Type Load Cell)

RoHS

TS502 Specification:

Capacity 2, 5, 10, 20, 30, 50, 100 (Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.028%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.03%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.02%F.S. Cable Length ∮5mm*2000mm

Hysteresis Error ±0.02%F.S. Protection Class IP66

Input Resistance 405±10Ω Wiring Code (4 wires, Braid Shielded, PVC Cable):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: S502

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* Used in Crane Scales, Tensile Application, etc.

TEKO®

25

TS502 ((S-Type Load Cell)

RoHS

TS502 Specification:

Capacity 2, 5, 10, 20, 30, 50, 100 (Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.028%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.03%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.02%F.S. Cable Length ∮5mm*2000mm

Hysteresis Error ±0.02%F.S. Protection Class IP66

Input Resistance 405±10Ω Wiring Code (4 wires, Braid Shielded, PVC Cable):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: S502

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* Used in Crane Scales, Tensile Application, etc.

TEKO®

25

TS502 ((S-Type Load Cell)

RoHS

TS502 Specification:

Capacity 2, 5, 10, 20, 30, 50, 100 (Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.028%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.03%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.02%F.S. Cable Length ∮5mm*2000mm

Hysteresis Error ±0.02%F.S. Protection Class IP66

Input Resistance 405±10Ω Wiring Code (4 wires, Braid Shielded, PVC Cable):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: S502

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* Used in Crane Scales, Tensile Application, etc.

TEKO®

25

NRS502 (S-Type Load Cell)TS502 ((S-Type Load Cell)

RoHS

TS502 Specification:

Capacity 2, 5, 10, 20, 30, 50, 100 (Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.028%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.03%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.02%F.S. Cable Length ∮5mm*2000mm

Hysteresis Error ±0.02%F.S. Protection Class IP66

Input Resistance 405±10Ω Wiring Code (4 wires, Braid Shielded, PVC Cable):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: S502

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* Used in Crane Scales, Tensile Application, etc.

TEKO®

25

NRS502 Specification:

Page 27: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it26

TS505 (S-Type Load Cell)

* Used in Crane Scales, Hopper Scales.

RoHS

TS501 Specification:

Capacity 1, 5, 10, 50(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.028%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 300%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮0.8mm*500mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 395±10Ω Wiring Code (4-color wires):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: S505Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

Tensile Application, etc.

26

TS505 (S-Type Load Cell)

* Used in Crane Scales, Hopper Scales.

RoHS

TS501 Specification:

Capacity 1, 5, 10, 50(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±10%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.028%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 300%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.015%F.S. Cable Length ∮0.8mm*500mm

Hysteresis Error ±0.015%F.S. Protection Class IP65

Input Resistance 395±10Ω Wiring Code (4-color wires):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: S505Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

* High Accuracy

Tensile Application, etc.

26

NRS505 (S-Type Load Cell)

NRS505 Specification:

Page 28: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it27

TS506 (S-Type Load Cell)

RoHS

TS506 Specification:

Capacity 100, 200, 300, 500, 1000, 1500(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.028%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.02%F.S. Cable Length ∮5mm*3000mm

Hysteresis Error ±0.02%F.S. Protection Class IP66

Input Resistance 385±10Ω Wiring Code (4 wires, Braid Shielded, PVC Cable):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: S506Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Alloy Steel Construction

* Used in Crane Scales, Tensile Application, etc.

27

TS506 (S-Type Load Cell)

RoHS

TS506 Specification:

Capacity 100, 200, 300, 500, 1000, 1500(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.028%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.02%F.S. Cable Length ∮5mm*3000mm

Hysteresis Error ±0.02%F.S. Protection Class IP66

Input Resistance 385±10Ω Wiring Code (4 wires, Braid Shielded, PVC Cable):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: S506Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Alloy Steel Construction

* Used in Crane Scales, Tensile Application, etc.

27

TS506 (S-Type Load Cell)

RoHS

TS506 Specification:

Capacity 100, 200, 300, 500, 1000, 1500(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.028%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.02%F.S. Cable Length ∮5mm*3000mm

Hysteresis Error ±0.02%F.S. Protection Class IP66

Input Resistance 385±10Ω Wiring Code (4 wires, Braid Shielded, PVC Cable):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: S506Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Alloy Steel Construction

* Used in Crane Scales, Tensile Application, etc.

27

NRS506 (S-Type Load Cell)

NRS506 Specification:

Page 29: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it28

TS507 (S-Type Load Cell)

RoHS

TS507 Specification:

Capacity 1000, 2000(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.028%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.02%F.S. Cable Length ∮5mm*3000mm

Hysteresis Error ±0.02%F.S. Protection Class IP66

Input Resistance 385±10Ω Wiring Code (4 wires, Braid Shielded, PVC Cable):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Alloy Steel Construction

* Used in Crane Scales, Tensile Application, etc.

TEKO®

www.TekoChina.com Document Number: S507Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

28

TS507 (S-Type Load Cell)

RoHS

TS507 Specification:

Capacity 1000, 2000(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.028%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.02%F.S. Cable Length ∮5mm*3000mm

Hysteresis Error ±0.02%F.S. Protection Class IP66

Input Resistance 385±10Ω Wiring Code (4 wires, Braid Shielded, PVC Cable):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Alloy Steel Construction

* Used in Crane Scales, Tensile Application, etc.

TEKO®

www.TekoChina.com Document Number: S507Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

28

TS507 (S-Type Load Cell)

RoHS

TS507 Specification:

Capacity 1000, 2000(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±5%mv/v Recommended Excitation 5 - 12VDC

Zero Balance ±2%F.S. Max. Excitation Voltage 18VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.028%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.02%F.S. Cable Length ∮5mm*3000mm

Hysteresis Error ±0.02%F.S. Protection Class IP66

Input Resistance 385±10Ω Wiring Code (4 wires, Braid Shielded, PVC Cable):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Alloy Steel Construction

* Used in Crane Scales, Tensile Application, etc.

TEKO®

www.TekoChina.com Document Number: S507Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

28

NRS507 (S-Type Load Cell)

NRS507 Specification:

Page 30: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it29

TF351 (Flat Type Load Cell)

* Aluminum Alloy Construction

* Flat Structure

* Used in Low Profile Scales, etc.

RoHS

TF351 TA601B Specification:

Capacity 30, 75, 150, 300(Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity (1.0-2.0)±10%mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*600mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: F351Document Version: 2007B

Features:

[email protected]

29

TF351 (Flat Type Load Cell)

* Aluminum Alloy Construction

* Flat Structure

* Used in Low Profile Scales, etc.

RoHS

TF351 TA601B Specification:

Capacity 30, 75, 150, 300(Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity (1.0-2.0)±10%mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*600mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: F351Document Version: 2007B

Features:

[email protected]

29

TF351 (Flat Type Load Cell)

* Aluminum Alloy Construction

* Flat Structure

* Used in Low Profile Scales, etc.

RoHS

TF351 TA601B Specification:

Capacity 30, 75, 150, 300(Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity (1.0-2.0)±10%mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*600mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: F351Document Version: 2007B

Features:

[email protected]

29

NRF351 (Flat Type Load Cell)

NRF351 Specification:

Page 31: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it30

TF353 (Flat Type Load Cell)

* Aluminum Alloy Construction

* Flat Structure

* Used in Low Profile Scales, etc.

RoHS

TF353 TA601B Specification:

Capacity 50, 75, 100, 150(Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*600mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: F353Document Version: 2007B

Features:

[email protected]

TF353 (Flat Type Load Cell)

* Aluminum Alloy Construction

* Flat Structure

* Used in Low Profile Scales, etc.

RoHS

TF353 TA601B Specification:

Capacity 50, 75, 100, 150(Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*600mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: F353Document Version: 2007B

Features:

[email protected]

NRF353 (Flat Type Load Cell)TF353 (Flat Type Load Cell)

* Aluminum Alloy Construction

* Flat Structure

* Used in Low Profile Scales, etc.

RoHS

TF353 TA601B Specification:

Capacity 50, 75, 100, 150(Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*600mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: F353Document Version: 2007B

Features:

[email protected]

NRF353 Specification:

Page 32: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it31

TF356 (Flat Type Load Cell)

* Aluminum Alloy Construction

* Flat Structure

* Used in Low Profile Scales, etc.

RoHS

TF356 TA601B Specification:

Capacity 75, 150, 300(Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*600mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: F356Document Version: 2007B

Features:

[email protected]

TF356 (Flat Type Load Cell)

* Aluminum Alloy Construction

* Flat Structure

* Used in Low Profile Scales, etc.

RoHS

TF356 TA601B Specification:

Capacity 75, 150, 300(Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*600mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: F356Document Version: 2007B

Features:

[email protected]

TF356 (Flat Type Load Cell)

* Aluminum Alloy Construction

* Flat Structure

* Used in Low Profile Scales, etc.

RoHS

TF356 TA601B Specification:

Capacity 75, 150, 300(Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*600mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: F356Document Version: 2007B

Features:

[email protected]

NRF356 (Flat Type Load Cell)

NRF356 Specification:

Page 33: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it32

TF357 (Flat Type Load Cell)

* Aluminum Alloy Construction

* Flat Structure

* Used in Low Profile Scales, etc.

RoHS

TF357 Specification:

Capacity 75, 150, 300(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 0.8±10%mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.03%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.03%F.S. Cable Length ∮0.8mm*600mm

Hysteresis Error ±0.03%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Document Version: 2007B

Features:

[email protected]

TEKO®

www.TekoChina.com Document Number: F357

32

TF357 (Flat Type Load Cell)

* Aluminum Alloy Construction

* Flat Structure

* Used in Low Profile Scales, etc.

RoHS

TF357 Specification:

Capacity 75, 150, 300(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 0.8±10%mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.03%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.03%F.S. Cable Length ∮0.8mm*600mm

Hysteresis Error ±0.03%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Document Version: 2007B

Features:

[email protected]

TEKO®

www.TekoChina.com Document Number: F357

32

NRF357 (Flat Type Load Cell)TF357 (Flat Type Load Cell)

* Aluminum Alloy Construction

* Flat Structure

* Used in Low Profile Scales, etc.

RoHS

TF357 Specification:

Capacity 75, 150, 300(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 0.8±10%mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.03%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.03%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.03%F.S. Cable Length ∮0.8mm*600mm

Hysteresis Error ±0.03%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Document Version: 2007B

Features:

[email protected]

TEKO®

www.TekoChina.com Document Number: F357

32

NRF357 Specification:

Page 34: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it33

TF358 (Flat Type Load Cell)

* Aluminum Alloy Construction

* Flat Structure

* Used in Low Profile Scales, etc.

RoHS

TF358 Specification:

Capacity 75, 125(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 0.8±10%mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.05mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.03%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*600mm

Hysteresis Error ±0.03%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: F358Document Version: 2007B

Features:

[email protected]

33

TF358 (Flat Type Load Cell)

* Aluminum Alloy Construction

* Flat Structure

* Used in Low Profile Scales, etc.

RoHS

TF358 Specification:

Capacity 75, 125(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 0.8±10%mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.05mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.03%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*600mm

Hysteresis Error ±0.03%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: F358Document Version: 2007B

Features:

[email protected]

33

NRF358 (Flat Type Load Cell)TF358 (Flat Type Load Cell)

* Aluminum Alloy Construction

* Flat Structure

* Used in Low Profile Scales, etc.

RoHS

TF358 Specification:

Capacity 75, 125(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 0.8±10%mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.05mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.03%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.03%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*600mm

Hysteresis Error ±0.03%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.03%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: F358Document Version: 2007B

Features:

[email protected]

33

NRF358 Specification:

Page 35: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it34

TF360 (Flat Type Load Cell)

* Steel Construction

* Flat Structure

* Used in Low Profile Scales, etc.

RoHS

TF360 Specification:

Capacity 50, 75(Kg)

Accuracy C1 Operating Temp. Range -10 - +40℃

Output Sensitivity (1.0±0.15%mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.3mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.3%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.2%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.1%F.S. Cable Length ∮0.8mm*420mm

Hysteresis Error ±0.2%F.S. Protection Class IP65

Input Resistance 1000±10Ω Wiring Code (3-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.3%F.S./10℃

Temp. Effect on Zero ±0.3%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

H

50Kg

7.8

Capacity: 75Kg

8.3

TEKO®

www.TekoChina.com Document Number: F360Document Version: 2007B

Features:

[email protected]

TF360 (Flat Type Load Cell)

* Steel Construction

* Flat Structure

* Used in Low Profile Scales, etc.

RoHS

TF360 Specification:

Capacity 50, 75(Kg)

Accuracy C1 Operating Temp. Range -10 - +40℃

Output Sensitivity (1.0±0.15%mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.3mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.3%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.2%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.1%F.S. Cable Length ∮0.8mm*420mm

Hysteresis Error ±0.2%F.S. Protection Class IP65

Input Resistance 1000±10Ω Wiring Code (3-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.3%F.S./10℃

Temp. Effect on Zero ±0.3%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

H

50Kg

7.8

Capacity: 75Kg

8.3

TEKO®

www.TekoChina.com Document Number: F360Document Version: 2007B

Features:

[email protected]

NRF360 (Flat Type Load Cell)

NRF360 Specification:

Page 36: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it35

TA601 TA601B (Single Point Load Cell)

* Aluminum Alloy Construction

* Miniature Structure

* Used in Electronic Balance, kitchen Scales, etc.

* Max. Platform Size: 150×150mm

RoHS

TA601 TA601B Specification:

Capacity 1, 3, 5, 10, 20(Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±20%mv/v Recommended Excitation ≤6VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*200mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: A601Document Version: 2007B

Features:

[email protected]

TYPE ATA601 5TA601B 4

35

TA601 TA601B (Single Point Load Cell)

* Aluminum Alloy Construction

* Miniature Structure

* Used in Electronic Balance, kitchen Scales, etc.

* Max. Platform Size: 150×150mm

RoHS

TA601 TA601B Specification:

Capacity 1, 3, 5, 10, 20(Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±20%mv/v Recommended Excitation ≤6VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*200mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: A601Document Version: 2007B

Features:

[email protected]

TYPE ATA601 5TA601B 4

35

TA601 TA601B (Single Point Load Cell)

* Aluminum Alloy Construction

* Miniature Structure

* Used in Electronic Balance, kitchen Scales, etc.

* Max. Platform Size: 150×150mm

RoHS

TA601 TA601B Specification:

Capacity 1, 3, 5, 10, 20(Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±20%mv/v Recommended Excitation ≤6VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*200mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: A601Document Version: 2007B

Features:

[email protected]

TYPE ATA601 5TA601B 4

35

NRA601 NRA601B (Single Point Load Cell)

NRA601 NRA601B Specification:

Page 37: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it36

TA603 TA603B (Single Point Load Cell)

* Aluminum Alloy Construction

* Miniature Structure

* Used in Pocket Scale and other weighing

application with limited space, etc.

RoHS

TA603 TA603B Specification:

Capacity 0.15, 0.3, 0.5, 0.7(Kg)

Accuracy C2 Operating Temp. Range -10 - +40℃

Output Sensitivity 0.65±20%mv/v Recommended Excitation ≤6VDC

Zero Balance ±15%F.S. Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.6mm*100mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: A603Document Version: 2007B

Features:

[email protected]

AΦ3.2M3

TYPETA603TA603B

36

TA603 TA603B (Single Point Load Cell)

* Aluminum Alloy Construction

* Miniature Structure

* Used in Pocket Scale and other weighing

application with limited space, etc.

RoHS

TA603 TA603B Specification:

Capacity 0.15, 0.3, 0.5, 0.7(Kg)

Accuracy C2 Operating Temp. Range -10 - +40℃

Output Sensitivity 0.65±20%mv/v Recommended Excitation ≤6VDC

Zero Balance ±15%F.S. Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.6mm*100mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: A603Document Version: 2007B

Features:

[email protected]

AΦ3.2M3

TYPETA603TA603B

36

NRA603 NRA603B (Single Point Load Cell)TA603 TA603B (Single Point Load Cell)

* Aluminum Alloy Construction

* Miniature Structure

* Used in Pocket Scale and other weighing

application with limited space, etc.

RoHS

TA603 TA603B Specification:

Capacity 0.15, 0.3, 0.5, 0.7(Kg)

Accuracy C2 Operating Temp. Range -10 - +40℃

Output Sensitivity 0.65±20%mv/v Recommended Excitation ≤6VDC

Zero Balance ±15%F.S. Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.6mm*100mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: A603Document Version: 2007B

Features:

[email protected]

AΦ3.2M3

TYPETA603TA603B

36

NRA603 NRA603B Specification:

Page 38: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it37

TA605 TA605B (Single Point Load Cell)

* Aluminum Alloy Construction

* Miniature Structure

* Used in Electronic Balance, kitchen Scales, etc.

RoHS

TA605 TA605B Specification:

Capacity 0.15, 0.2, 0.3, 0.5, 1(Kg)

Accuracy C1 Operating Temp. Range -20 - +60℃

Output Sensitivity ±0.1mv/v Recommended Excitation ≤6VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*200mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TYPE ATA605 5.2TA605B 3.2

TEKO®

www.TekoChina.com Document Number: A605Document Version: 2007B

Features:

[email protected]

TA605 TA605B (Single Point Load Cell)

* Aluminum Alloy Construction

* Miniature Structure

* Used in Electronic Balance, kitchen Scales, etc.

RoHS

TA605 TA605B Specification:

Capacity 0.15, 0.2, 0.3, 0.5, 1(Kg)

Accuracy C1 Operating Temp. Range -20 - +60℃

Output Sensitivity ±0.1mv/v Recommended Excitation ≤6VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*200mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TYPE ATA605 5.2TA605B 3.2

TEKO®

www.TekoChina.com Document Number: A605Document Version: 2007B

Features:

[email protected]

TA605 TA605B (Single Point Load Cell)

* Aluminum Alloy Construction

* Miniature Structure

* Used in Electronic Balance, kitchen Scales, etc.

RoHS

TA605 TA605B Specification:

Capacity 0.15, 0.2, 0.3, 0.5, 1(Kg)

Accuracy C1 Operating Temp. Range -20 - +60℃

Output Sensitivity ±0.1mv/v Recommended Excitation ≤6VDC

Zero Balance ±5%F.S. Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*200mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TYPE ATA605 5.2TA605B 3.2

TEKO®

www.TekoChina.com Document Number: A605Document Version: 2007B

Features:

[email protected]

NRA605 NRA605B (Single Point Load Cell)

NRA605 NRA605B Specification:

Page 39: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it38

TA610 (Single Point Load Cell)

* Aluminum Alloy Construction

* Miniature Structure

* Used in kitchen Scales,

and other application, etc.

RoHS

TA610 TA601B Specification:

Capacity 0.02, 0.03, 0.05, 0.1, 0.2(Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±30%mv/v Recommended Excitation ≤6VDC

Zero Balance ±20%F.S. Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*100mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Document Version: 2007B

Features:

[email protected]

TEKO®

www.TekoChina.com Document Number: A610

38

TA610 (Single Point Load Cell)

* Aluminum Alloy Construction

* Miniature Structure

* Used in kitchen Scales,

and other application, etc.

RoHS

TA610 TA601B Specification:

Capacity 0.02, 0.03, 0.05, 0.1, 0.2(Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±30%mv/v Recommended Excitation ≤6VDC

Zero Balance ±20%F.S. Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 150%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 200%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮0.8mm*100mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 1130±20Ω Wiring Code (4-color wires):

Output Resistance 1000±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Document Version: 2007B

Features:

[email protected]

TEKO®

www.TekoChina.com Document Number: A610

38

NRA610 (Single Point Load Cell)

NRA610 Specification:

Page 40: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it39

TC301 (Force Load Cells)

with limited space.

RoHS

TC301 Specification:

Capacity 5, 10, 20, (Kg)

Accuracy C1 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±1%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±1%F.S. Ultimate Overload 150%F.S.

Linearity Error ±1%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±1%F.S. Cable Length ∮2.2mm*2000mm

Hysteresis Error ±1%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±1%F.S./10℃

Temp. Effect on Zero ±1%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: C301

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Used in force testing applications

* Aluminum Alloy Construction

or Stainless Steel.

TEKO®

39

TC301 (Force Load Cells)

with limited space.

RoHS

TC301 Specification:

Capacity 5, 10, 20, (Kg)

Accuracy C1 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±1%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±1%F.S. Ultimate Overload 150%F.S.

Linearity Error ±1%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±1%F.S. Cable Length ∮2.2mm*2000mm

Hysteresis Error ±1%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±1%F.S./10℃

Temp. Effect on Zero ±1%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: C301

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Used in force testing applications

* Aluminum Alloy Construction

or Stainless Steel.

TEKO®

39

TC301 (Force Load Cells)

with limited space.

RoHS

TC301 Specification:

Capacity 5, 10, 20, (Kg)

Accuracy C1 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±1%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±1%F.S. Ultimate Overload 150%F.S.

Linearity Error ±1%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±1%F.S. Cable Length ∮2.2mm*2000mm

Hysteresis Error ±1%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±1%F.S./10℃

Temp. Effect on Zero ±1%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: C301

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Used in force testing applications

* Aluminum Alloy Construction

or Stainless Steel.

TEKO®

39

NRC301 (Force Load Cells)

NRC301 Specification:

Page 41: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it40

TC302 (Force Load Cells)

with limited space.

RoHS

TC302 Specification:

Capacity 5, 10, 20, 50(Kg)

Accuracy C1 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±1%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±1%F.S. Ultimate Overload 150%F.S.

Linearity Error ±1%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±1%F.S. Cable Length ∮2.2mm*2000mm

Hysteresis Error ±1%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±1%F.S./10℃

Temp. Effect on Zero ±1%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: C302Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Used in force testing applications

* Aluminum Alloy Construction

or Stainless Steel.

40

TC302 (Force Load Cells)

with limited space.

RoHS

TC302 Specification:

Capacity 5, 10, 20, 50(Kg)

Accuracy C1 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±1%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±1%F.S. Ultimate Overload 150%F.S.

Linearity Error ±1%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±1%F.S. Cable Length ∮2.2mm*2000mm

Hysteresis Error ±1%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±1%F.S./10℃

Temp. Effect on Zero ±1%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: C302Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Used in force testing applications

* Aluminum Alloy Construction

or Stainless Steel.

40

NRC302 (Force Load Cells)

NRC302 Specification:

Page 42: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it41

TC303 (Force Load Cells)

with limited space.

RoHS

TC303 Specification:

Capacity 5, 10, 20, 50(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±0.02%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.02%F.S. Cable Length ∮3mm*2000mm

Hysteresis Error ±0.02%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: C303

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Used in force testing applications

* Aluminum Alloy Construction

or Stainless Steel.

TEKO®

41

TC303 (Force Load Cells)

with limited space.

RoHS

TC303 Specification:

Capacity 5, 10, 20, 50(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±0.02%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.02%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.02%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.02%F.S. Cable Length ∮3mm*2000mm

Hysteresis Error ±0.02%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.02%F.S./10℃

Temp. Effect on Zero ±0.02%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: C303

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Used in force testing applications

* Aluminum Alloy Construction

or Stainless Steel.

TEKO®

41

NRC303 (Force Load Cells)

NRC303 Specification:

Page 43: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it42

TC304 (Force Load Cells)

with limited space.

RoHS

TC304 Specification:

Capacity 20, 50, 100, 200, 300, 500 (Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮3mm*2000mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shilded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Used in force testing applications

* Aluminum Alloy Construction

or Stainless Steel.

TEKO®

www.TekoChina.com Document Number: C304Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

42

NRC304 (Force Load Cells)TC304 (Force Load Cells)

with limited space.

RoHS

TC304 Specification:

Capacity 20, 50, 100, 200, 300, 500 (Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮3mm*2000mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shilded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Used in force testing applications

* Aluminum Alloy Construction

or Stainless Steel.

TEKO®

www.TekoChina.com Document Number: C304Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

42

TC304 (Force Load Cells)

with limited space.

RoHS

TC304 Specification:

Capacity 20, 50, 100, 200, 300, 500 (Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮3mm*2000mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shilded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

* Used in force testing applications

* Aluminum Alloy Construction

or Stainless Steel.

TEKO®

www.TekoChina.com Document Number: C304Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

42

NRC304 Specification:

Page 44: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it43

TC305 (Force Load Cells)

with limited space.

RoHS

TC305 Specification:

Capacity 50, 100, 200, 300, 500 (Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮3mm*2000mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: C305

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Used in force testing applications

* Aluminum Alloy Construction

or Stainless Steel.

TEKO®

43

TC305 (Force Load Cells)

with limited space.

RoHS

TC305 Specification:

Capacity 50, 100, 200, 300, 500 (Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮3mm*2000mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: C305

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Used in force testing applications

* Aluminum Alloy Construction

or Stainless Steel.

TEKO®

43

TC305 (Force Load Cells)

with limited space.

RoHS

TC305 Specification:

Capacity 50, 100, 200, 300, 500 (Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮3mm*2000mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.www.TekoChina.com Document Number: C305

Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Used in force testing applications

* Aluminum Alloy Construction

or Stainless Steel.

TEKO®

43

NRC305 (Force Load Cells)

NRC305 Specification:

Page 45: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it44

TC306S (Force Load Cells)

* Used in force testing applications

TC306S Specification:

Capacity 5, 10, 20, 30, 50, 100, 200, 300, 500, 1000, 2000(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 1-1.5mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.05%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.04%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.04%F.S. Cable Length ∮3mm*3000mm

Hysteresis Error ±0.04%F.S. Protection Class IP65

Input Resistance 350±18Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Stainless Steel Construction

TEKO®

Document Number: C306Swww.TekoChina.comDocument Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

with limited space.

44

TC306S (Force Load Cells)

* Used in force testing applications

TC306S Specification:

Capacity 5, 10, 20, 30, 50, 100, 200, 300, 500, 1000, 2000(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 1-1.5mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.05%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.04%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.04%F.S. Cable Length ∮3mm*3000mm

Hysteresis Error ±0.04%F.S. Protection Class IP65

Input Resistance 350±18Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Stainless Steel Construction

TEKO®

Document Number: C306Swww.TekoChina.comDocument Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

with limited space.

44

TC306S (Force Load Cells)

* Used in force testing applications

TC306S Specification:

Capacity 5, 10, 20, 30, 50, 100, 200, 300, 500, 1000, 2000(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 1-1.5mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.05%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.04%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.04%F.S. Cable Length ∮3mm*3000mm

Hysteresis Error ±0.04%F.S. Protection Class IP65

Input Resistance 350±18Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Stainless Steel Construction

TEKO®

Document Number: C306Swww.TekoChina.comDocument Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

with limited space.

44

TC306S (Force Load Cells)

* Used in force testing applications

TC306S Specification:

Capacity 5, 10, 20, 30, 50, 100, 200, 300, 500, 1000, 2000(Kg)

Accuracy C3 Operating Temp. Range -20 - +60℃

Output Sensitivity 1-1.5mv/v Recommended Excitation ≤10VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 10VDC

Combined Error ±0.05%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.04%F.S. Insulation Resistance ≥5000MΩ(50VDC)

Repeatability Error ±0.04%F.S. Cable Length ∮3mm*3000mm

Hysteresis Error ±0.04%F.S. Protection Class IP65

Input Resistance 350±18Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±5Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -

Note:* Size, Cable Length, Capacity and Thread Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

Stainless Steel Construction

TEKO®

Document Number: C306Swww.TekoChina.comDocument Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

with limited space.

44

NRC306S (Force Load Cells)

NRC306S Specification:

Page 46: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it45

TC320 (Force Load Cells)

* Used in force testing applications

with limited space.

RoHS

TC320 Specification:

Capacity 100, 200, 300, 500, 1000 (Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮3mm*2000mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Screw Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: C320Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Stainless Steel Construction

45

TC320 (Force Load Cells)

* Used in force testing applications

with limited space.

RoHS

TC320 Specification:

Capacity 100, 200, 300, 500, 1000 (Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮3mm*2000mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Screw Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: C320Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Stainless Steel Construction

45

TC320 (Force Load Cells)

* Used in force testing applications

with limited space.

RoHS

TC320 Specification:

Capacity 100, 200, 300, 500, 1000 (Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮3mm*2000mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Screw Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: C320Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Stainless Steel Construction

45

NRC320 (Force Load Cells)

NRC320 Specification:

Page 47: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it46

TC321 (Force Load Cells)

* Used in force testing applications

with limited space.

RoHS

TC321 Specification:

Capacity 100, 200, 300, 500, 1000 (Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮3mm*2000mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Screw Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: C321Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Stainless Steel Construction

46

TC321 (Force Load Cells)

* Used in force testing applications

with limited space.

RoHS

TC321 Specification:

Capacity 100, 200, 300, 500, 1000 (Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮3mm*2000mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Screw Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: C321Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Stainless Steel Construction

46

TC321 (Force Load Cells)

* Used in force testing applications

with limited space.

RoHS

TC321 Specification:

Capacity 100, 200, 300, 500, 1000 (Kg)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 2.0±0.5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±0.05%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.05%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.05%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.05%F.S. Cable Length ∮3mm*2000mm

Hysteresis Error ±0.05%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-wire, Braid shielded, PVC Cable):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.05%F.S./10℃

Temp. Effect on Zero ±0.05%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Screw Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: C321Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Stainless Steel Construction

46

NRC321 (Force Load Cells)

NRC321 Specification:

Page 48: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it47

TC341 (Force Load Cells)

* Used in force testing applications

with limited space.

RoHS

TC341 Specification:

Capacity 1, 5, 10, 20 (Nm)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.01mv/v Max. Excitation Voltage 6VDC

Combined Error ±1%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±1%F.S. Ultimate Overload 150%F.S.

Linearity Error ±1%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±1%F.S. Cable Length ∮0.6mm*100mm

Hysteresis Error ±1%F.S. Protection Class IP65

Input Resistance 395±10Ω Wiring Code (4-color wires):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.01%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Screw Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: C341Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

47

TC341 (Force Load Cells)

* Used in force testing applications

with limited space.

RoHS

TC341 Specification:

Capacity 1, 5, 10, 20 (Nm)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.01mv/v Max. Excitation Voltage 6VDC

Combined Error ±1%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±1%F.S. Ultimate Overload 150%F.S.

Linearity Error ±1%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±1%F.S. Cable Length ∮0.6mm*100mm

Hysteresis Error ±1%F.S. Protection Class IP65

Input Resistance 395±10Ω Wiring Code (4-color wires):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.01%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Screw Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: C341Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

47

NRC341 (Force Load Cells)TC341 (Force Load Cells)

* Used in force testing applications

with limited space.

RoHS

TC341 Specification:

Capacity 1, 5, 10, 20 (Nm)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.01mv/v Max. Excitation Voltage 6VDC

Combined Error ±1%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±1%F.S. Ultimate Overload 150%F.S.

Linearity Error ±1%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±1%F.S. Cable Length ∮0.6mm*100mm

Hysteresis Error ±1%F.S. Protection Class IP65

Input Resistance 395±10Ω Wiring Code (4-color wires):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.01%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Screw Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: C341Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

47

TC341 (Force Load Cells)

* Used in force testing applications

with limited space.

RoHS

TC341 Specification:

Capacity 1, 5, 10, 20 (Nm)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±10%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.01mv/v Max. Excitation Voltage 6VDC

Combined Error ±1%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±1%F.S. Ultimate Overload 150%F.S.

Linearity Error ±1%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±1%F.S. Cable Length ∮0.6mm*100mm

Hysteresis Error ±1%F.S. Protection Class IP65

Input Resistance 395±10Ω Wiring Code (4-color wires):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.01%F.S./10℃

Temp. Effect on Zero ±2%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Screw Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: C341Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

47

NRC341 Specification:

Page 49: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

www.newresistance.it48

TC361 (Force Load Cells)

* Used in 3-axis force testing applications

RoHS

TC361 Specification:

Capacity 10, 20, 30, 50 (N)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±0.2%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.2%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.2%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.2%F.S. Cable Length ∮3mm*2000mm

Hysteresis Error ±0.2%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-color wires):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.1%F.S./10℃

Temp. Effect on Zero ±0.5%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Screw Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: C361Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

48

TC361 (Force Load Cells)

* Used in 3-axis force testing applications

RoHS

TC361 Specification:

Capacity 10, 20, 30, 50 (N)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±0.2%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.2%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.2%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.2%F.S. Cable Length ∮3mm*2000mm

Hysteresis Error ±0.2%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-color wires):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.1%F.S./10℃

Temp. Effect on Zero ±0.5%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Screw Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: C361Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

48

NRC361 (Force Load Cells)

TC361 (Force Load Cells)

* Used in 3-axis force testing applications

RoHS

TC361 Specification:

Capacity 10, 20, 30, 50 (N)

Accuracy C2 Operating Temp. Range -20 - +60℃

Output Sensitivity 1.0±5%mv/v Recommended Excitation ≤6VDC

Zero Balance ±0.1mv/v Max. Excitation Voltage 6VDC

Combined Error ±0.2%F.S. Safe Overload 120%F.S.

Creep in 30 Minutes ±0.2%F.S. Ultimate Overload 150%F.S.

Linearity Error ±0.2%F.S. Insulation Resistance ≥2000MΩ(50VDC)

Repeatability Error ±0.2%F.S. Cable Length ∮3mm*2000mm

Hysteresis Error ±0.2%F.S. Protection Class IP65

Input Resistance 350±10Ω Wiring Code (4-color wires):

Output Resistance 350±10Ω

Temp. Effect on Sensitivity ±0.1%F.S./10℃

Temp. Effect on Zero ±0.5%F.S./10℃

Compensated Temp. Range -10 - +40℃

Note:* Size, Cable Length, Capacity and Screw Type Could be Customized according to your requirement.

* All specifications subject to change without notice, please confirm before order.

TEKO®

www.TekoChina.com Document Number: C361Document Version: 2007B

Features:

[email protected]

* Comply with OIML Standard

* Aluminum Alloy Construction

48

NRC361 Specification:

Page 50: Load Cell Catalogue - newresistance.it · Load Cell Catalogue. PRCSN RSSTRS Single Point Load Cells Shear Beam Load Cells S-Type Load Cells Planar Beam Load Cells Miniature Load Cells

P R E C I S I O N R E S I S T O R S

Via Garibaldi, 21 - 20092 Cinisello Balsamo (MI) - Telefono: 02 61.27.759 - Fax: 02 61.28.449www.newresistance.it