Page 1: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

Linda Kincaid, MPH, [email protected]

Page 2: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

125 ppb:Kitchen – Room Air

100 ppb: Illness in most adults

77 ppb: FEMA trailer average

60 ppb:Asthma in children

27 ppb:Recommended 8-hour exposure limit

Page 3: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

141 ppb:Bedroom - Room Air

100 ppb: Illness in most adults

77 ppb: FEMA trailer average

60 ppb:Asthma in children

27 ppb:Recommended 8-hour exposure limit

Page 4: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

145 ppb:Office – Room Air

100 ppb: Illness in most adults

77 ppb: FEMA trailer average

60 ppb:Asthma in children

27 ppb:Recommended 8-hour exposure limit

Page 5: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

291 ppb:Pantry – Room Air(Designed to be Greenpoint Rated)

100 ppb: Illness in most adults

77 ppb: FEMA trailer average

60 ppb:Asthma in children

27 ppb:Recommended exposure limit

Page 6: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

Why Do We Care?Public Health Concern Legal Liability – Prop 65

Eye & respiratory irritant

Asthma in childrenCancer

Page 7: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

413 ppb:Inside Cabinet(Designed to be GreenPoint Rated)

100 ppb: Illness in most adults

77 ppb: FEMA trailer average

60 ppb:Asthma in children

27 ppb:Recommended 8-hour exposure limit

Page 8: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

464 ppb:Inside Cabinet(GreenPoint Rated)

100 ppb: Illness in most adults

77 ppb: FEMA trailer average

60 ppb:Asthma in children

27 ppb:Recommended 8-hour exposure limit

Page 9: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

696 ppb:Inside Cabinet

100 ppb: Illness in most adults

77 ppb: FEMA trailer average

60 ppb:Asthma in children

27 ppb:Recommended 8-hour exposure limit

Page 10: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

1,010 ppb:Inside Cabinet

100 ppb: Illness in most adults

77 ppb: FEMA trailer average

60 ppb:Asthma in children

27 ppb:Recommended 8-hour exposure limit

Page 11: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

Performance Core:Engineered Plywood for Cabinets

Advertises:

“No added urea-formaldehyde”

“0 ppm formaldehyde emissions”

Page 12: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

604 ppb:Performance CoreSample in Test Box

100 ppb: Illness in most adults

77 ppb: FEMA trailer average

60 ppb:Asthma in children

27 ppb:Recommended 8-hour exposure limit

Page 13: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

Formaldehyde in Furniture

Adds to formaldehyde in homesBedroom is most importantChildren are more sensitive

Page 14: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

67 ppb:Baby Crib – Child’s Breathing Zone

100 ppb: Illness in most adults

77 ppb: FEMA trailer average

60 ppb:Asthma in children

27 ppb:Recommended 8-hour exposure limit

Page 15: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

93 ppb:Changing Table - Child’s Breathing Zone

100 ppb: Illness in most adults

77 ppb: FEMA trailer average

60 ppb:Asthma in children

27 ppb:Recommended 8-hour exposure limit

Page 16: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

613 ppb:Changing Table Drawer – Formaldehyde clings to fabrics100 ppb: Illness in most adults

77 ppb: FEMA trailer average

60 ppb:Asthma in children

27 ppb:Recommended 8-hour exposure limit

Page 17: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

Summary

Any home can have too much formaldehydeGreenPoint homes don’t have enough

ventilationFurniture adds to formaldehyde in the home

Page 18: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

Recommendations

Ventilation is necessaryMechanical ventilation is not enoughChoose products with low/no formaldehyde

Testing is the only way to know for sure

Page 19: Linda Kincaid, MPH, CIH NanoSafety@gmail.com. 125 ppb: Kitchen – Room Air 100 ppb: Illness in most adults 77 ppb: FEMA trailer average 60 ppb: Asthma

[email protected](408) 998-4642

IndoorAirAnswers.com

Examiner.comSan Jose Environmental Health Examiner