lakeview & plaza middle schools track renovation kansas ... · 5.provide 2 quick coupling keys...

7
Lakeview & Plaza Middle Schools Track Renovation Kansas City, MO ADDENDUM #2 January 24, 2019 This addendum forms a part of the Contract Documents and modifies the original Bid Documents and Project Manual dated January 8, 2019. Acknowledgement of the addendum is required in the Bid Form. CLARIFICATIONS: 1. A 25flagpole is to be provided and installed at both middle school sites. Location will generally be between the school and the track and will be field located during construction. The flagpole will not be lit. See attached cut sheet as the Basis of Design, Eder Flag, 25tall Model ECX25. CHANGES TO PROJECT MANUAL 1. N/A CHANGES TO DRAWINGS 1. Lakeview MS Sheet C605 Remove and replace in its entirety with the attached sheet. (Drainage Revisions) 2. Lakeview MS Sheet PF1.01 Remove and replace in its entirety with the attached sheet. (revised radius dimensions) 3. Lakeview MS Sheet PF3.01 & PF3.02 Remove and replace in its entirety with the attached sheet. (Clarification of irrigation materials) 4. Plaza MS Sheet PF3.01 Remove and replace in its entirety with the attached sheet. (Clarification of irrigation materials) END OF ADDENDUM 2

Upload: others

Post on 07-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Lakeview & Plaza Middle Schools Track Renovation Kansas ... · 5.provide 2 quick coupling keys (1" male outlet) and sh-2 swivel hose ell for each key. 6.route 2 spare wires from controller

Lakeview & Plaza Middle Schools Track Renovation Kansas City, MO ADDENDUM #2 January 24, 2019 This addendum forms a part of the Contract Documents and modifies the original Bid Documents and Project Manual dated January 8, 2019. Acknowledgement of the addendum is required in the Bid Form. CLARIFICATIONS: 1. A 25’ flagpole is to be provided and installed at both middle school sites. Location will generally be

between the school and the track and will be field located during construction. The flagpole will not be lit. See attached cut sheet as the Basis of Design, Eder Flag, 25’ tall Model ECX25.

CHANGES TO PROJECT MANUAL

1. N/A CHANGES TO DRAWINGS

1. Lakeview MS Sheet C605 – Remove and replace in its entirety with the attached sheet. (Drainage

Revisions) 2. Lakeview MS Sheet PF1.01 – Remove and replace in its entirety with the attached sheet. (revised

radius dimensions) 3. Lakeview MS Sheet PF3.01 & PF3.02 – Remove and replace in its entirety with the attached sheet.

(Clarification of irrigation materials)

4. Plaza MS Sheet PF3.01 – Remove and replace in its entirety with the attached sheet. (Clarification of irrigation materials)

END OF ADDENDUM 2

Page 2: Lakeview & Plaza Middle Schools Track Renovation Kansas ... · 5.provide 2 quick coupling keys (1" male outlet) and sh-2 swivel hose ell for each key. 6.route 2 spare wires from controller

Aluminum flash collar

3000 PSI concrete

Hardwood wedges(supplied by others)

Dry sand tightly tamped after aligning poleFoundation sleeve -16 ga hot dip galvanized steel

Steel centering wedges

1/4" Steel base plate

1/4" Steel support plate welded to grounding spike

Tape

red

porti

on:

11'-0

"S

traig

ht p

ortio

n: 1

6'-0

"

Project:Location:Architect:ContractorCustomer:

EDER FLAGMANUFACTURING COMPANY

1000 W. Rawson AvenueOak Creek, WI 53154

Date: Revision:

Job:

Pol

e le

ngth

: 27

'-0"

Foun

datio

n: 3

'-6"

Cle

at h

eigh

t: 5

'-0"

Model ECX25

8"

16"

30"

12"

6"

Ground set tapered aluminum flagpole: ALLOY: 6063T6Exposed height: 25'-0" Pole length: 27'-0"Ship in 1 section Butt diameter: 5"Top diameter: 3" Wall thickness: .125"Finish: 100 grit polish

3'-0

"

5" - 14 gauge spun aluminum ball gold anodized.

Single sheave truck, cast aluminum revolving, non fouling type

1 Set of halyard, #10 poly

1 - 9" Cast Aluminum Cleat

All shafts with overalllength of more than 38'-6" are shipped in two sections.

Each section matchedmarked for field assembly. Exposed portion of jamsleeve must be well lubricated prior toassembly.

1-1/2" maximum shopgap allowed for field fitting (ram for tight joint)

2 Bronze swival snaps with covers

Ove

rall

leng

th:

28'-0

"

Truck Detail

Aluminum bodyStainless steel ball bearingsAluminum sheaveCast aluminum spindle

Page 3: Lakeview & Plaza Middle Schools Track Renovation Kansas ... · 5.provide 2 quick coupling keys (1" male outlet) and sh-2 swivel hose ell for each key. 6.route 2 spare wires from controller

TRA

CK

AN

D P

LAYF

IELD

IMP

RO

VEM

ENTS

NUMBERPE-2011037427

DAVID D.WOOD

PRO

FES S I ONAL ENGI NEER

STATE OF MI SSOUR

I

LAK

EVIE

W M

IDD

LE S

CH

OO

L &

ENG

LIS

H L

AN

DIN

G E

LEM

ENTA

RY

SC

HO

OL

6720

NW

64T

H S

TREE

T &

650

0 N

W K

LAM

M D

RIV

EK

AN

SA

S C

ITY,

MO

641

51

STO

RM

PLA

N -

SOU

TH

Know what's below.before you dig.Call

R

Page 4: Lakeview & Plaza Middle Schools Track Renovation Kansas ... · 5.provide 2 quick coupling keys (1" male outlet) and sh-2 swivel hose ell for each key. 6.route 2 spare wires from controller

FOOTBALL

360'-0"

FO

OT

BA

LL

160' X

360'

GOAL POST

INSTALL COMBOX

WITH TURFCOVER

PLACE 1.5" CONDUIT FROM

COMBOX TO PLAY CLOCK.

ROUTE ADJACENT TO TRACK

AND RUN PARALLEL TO THE

BACK OF THE FIELD.

GOAL POST

6

SP 4.01

INSTALL COMBOX

WITH TURF COVER

INSTALL COMBOX

WITH TURF COVER

INSTALL COMBOX

WITH TURF COVER

R

9

5

'

-

2

"

R190'-3"

R

9

5

'

-

2

"

48'-3"

R

9

5

'

-

2

"

R

9

5

'

-

2

"

48'-3"

82'-0" 82'-0"92'-1"

R190'-3

"

67'-1"

67'-1"

10'-0"

30'-0" 149'-6" 30'-0"

13'-1"

13'-1"

50'-0"

50'-0"

50'-0"

HIGH JUMP PAD

RE: DETAILS

MEASURE POINT,

RE: CIVIL FOR RADIUS

POINT LOCATION

MEASURE POINT,

RE: CIVIL FOR RADIUS

POINT LOCATION

MEASURE POINT,

RE: CIVIL FOR RADIUS

POINT LOCATION

MEASURE POINT,

RE: CIVIL FOR RADIUS

POINT LOCATION

MEASURE POINT,

RE: CIVIL FOR RADIUS

POINT LOCATION

VSR DesignLandscape Architecture-Planning-Sports-Recreation

P.O. Box 7608Overland Park, KS 66207ph: (913) 484-5211

Kaw Valley Engineering, Inc.Survey & Civil14700 W. 114th TerraceLenexa, KS 66215ph: (913) 894-5150

Smith & Boucher, Inc.Electrical Engineering25501 Valley Parkway, Suite 200Olathe, KS 66061ph: (913) 344-0029

01.08.19

SCALE

1" =

0

FEET

LEGEND

PF 1.01

TRACK

LAYOUT + MATERIALS

20'-0"

20' 20'

GENERAL NOTES

1. ALL UTILITIES SHOWN ON PLANS ARE BASED ON ABOVE GROUND OBSERVATION AND MAY NOT INCLUDE ALL LINES PRESENT. VSRDESIGN ACCEPTS NO

RESPONSIBILITY FOR THE ACCURACY OF THE UTILITY LOCATIONS AS SHOWN. ALL UTILITIES ARE TO BE FIELD LOCATED PRIOR TO EXCAVATION. CONTACT

MISSOURI ONE-CALL, INDIVIDUAL UTILITY COMPANIES, AND OWNER FOR FIELD LOCATES. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR DAMAGE

TO EXISTING UTILITIES, WHETHER SHOWN ON THE PLANS OR NOT.

2. THE CONTRACTOR SHALL MEET THE REQUIREMENTS OF ALL FEDERAL, STATE, AND LOCAL CODES HAVING JURISDICTION OVER THE WORK.

3. THE CONTRACTOR SHALL PAY ALL PERMIT FEES AND OTHER ASSOCIATED FEES REQUIRED TO SUCCESSFULLY COMPLETE THE PROJECT.

4. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE PLANS AND REQUIREMENTS OF THE CONSTRUCTION SPECIFICATIONS.CLARIFICATION OF ANY

DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS SHALL BE MADE BY OWNER AND/OR ENGINEER/ARCHITECT.

5. A CADD DISK (AUTOCAD R2007) WILL BE MADE AVAILABLE TO THE CONTRACTOR FOR LAYOUT AND STAKING PURPOSES IF DESIRED, FOR A FEE AS

DESIGNATED IN THE CONTRACT SPECIFICATIONS. ALLOW ONE WEEK FOR THE ARCHITECT/ENGINEER TO PROCESS THE DISK. THE ARCHITECT/ENGINEER

BELIEVES THE DISK TO BE ACCURATE, HOWEVER THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFIRMING THAT THE INFORMATION ON THE DISK

CONFORMS TO THE DIMENSIONS AND ELEVATIONS SHOWN ON THE DRAWINGS.

6. ALL EQUIPMENT USED ON NATURAL TURF PLAYING FIELDS SHALL BE EQUIPPED WITH FLOTATION TURF TIRES OR "TRACKS" TO PREVENT OVER-COMPACTION

OF SOILS. PLAYING FIELD SURFACES TO HAVE COMPACTION BETWEEN 85-90%. ANY AREAS WITH HIGHER COMPACTION SHALL BE RIPPED/DISKED TO A

DEPTH OF 12" AND RE-GRADED.

KEYED NOTES

1 PROVIDE AND INSTALL HIGH JUMP EVENT AREA WITH 1/2" POLYURETHANE RESILIENT

TRACK SURFACING.

2 PROVIDE AND INSTALL 400 METER, 6-LANE RUNNING TRACK WITH 1/2"

POLYURETHANE RESILIENT TRACK SURFACING AND STRIPING

3 PROVIDE AND INSTALL LONG/TRIPLE JUMP RUNWAY WITH SAND JUMP PITS, RE:

4/PF4.02

4 PROVIDE AND INSTALL POLE VAULT PAD/RUNWAY AND STRIPING, RE: 6/PF4.01

5 PROVIDE AND INSTALL SHOT PUT CONCRETE PAD & LIMESTONE SCREENINGS AND

INSTALL 6" X12" CONCRETE CURB AND 4" DEPTH LIMESTONE SCREENINGS.

6 PROVIDE AND INSTALL CONCRETE FIELD CURB, RE: 2/ PF4.01

7 PROVIDE AND INSTALL PERIMETER TRACK WALK, RE: 1/PF4.02

8 PROVIDE AND INSTALL (2) - 4" AND (2)-2" SCH. 40 PVC SLEEVES FOR FUTURE

CONTROL WIRE. EXTEND 12" BEYOND EDGE OF PAVEMENT & CAP. INSTALL REBAR

FOR FUTURE LOCATIONS.

9 PROVIDE AND INSTALL GALVANIZED CHAIN LINK FENCE.

10 PROVIDE AND INSTALL 5' WIDE GALVANIZED CHAIN LINK SINGLE GATE.

11 PROVIDE AND INSTALL 20' WIDE GALVANIZED CHAIN LINK DOUBLE GATE.

12 PROVIDE AND INSTALL 10' WIDE GALVANIZED CHAIN LINK DOUBLE GATE.

13 ALL DISTURBED AREAS WILL BE SEEDED WITH 1 0LBS OF FESCUE SEED PER 1,000 SF.

14 ALL SLOPES GREATER THAN 4:1 SHALL RECEIVE A 6-12 MONTH EROSION CONTROL

BLANKET, OR HYDRO-MULCH.

S

T

A

T

E

O

F M

I

S

S

O

U

R

I

VANCE S.

RZEPKA

NUMBER

LA-000144

S

T

A

T E O F MI S S OU

R

I

VANCE S.

RZEPKA

NUMBER

LA-000144

vance rzepka
Text Box
R 95.1326'
vance rzepka
Text Box
R 190.2854'
vance rzepka
Text Box
R 95.1326'
vance rzepka
Text Box
R 95.1326'
vance rzepka
Text Box
R 95.1326'
vance rzepka
Text Box
R 190.2854'
vance rzepka
Text Box
2
vance rzepka
Text Box
2
vance rzepka
Text Box
2
vance rzepka
Text Box
2
vance rzepka
Text Box
2
vance rzepka
Text Box
2
vance rzepka
Text Box
1.24.19 ADD #2
vance rzepka
Text Box
2
vance rzepka
Text Box
vance rzepka
Pen
Page 5: Lakeview & Plaza Middle Schools Track Renovation Kansas ... · 5.provide 2 quick coupling keys (1" male outlet) and sh-2 swivel hose ell for each key. 6.route 2 spare wires from controller

REMOTE CONTROL VALVE

MODEL ICV - SIZE AS NOTED ON PLAN

FINISH GRADE

3/4" MINUS WASHED GRAVEL

BRICK SUPPORTS (4)

MAIN LINE PIPE &

FITTINGS

SCH 80 T.O.E. NIPPLE

STANDARD VALVE BOX

WATERPROOF CONNECTORS (2)

18-24" COILED WIRE

PVC SLIP UNIONS

CHRISTY ID TAG

LATERAL PIPE

LATERAL TEE OR ELL

MODEL I-25 ROTOR HEAD

PREFABRICATED SWING JOINT

FINISH GRADE

RUBBER COVER

CONTROL WIRE IN ELECTRICAL

CONDUIT. SIZE AND TYPE

PER LOCAL CODE

* NOTE:

18 STATION MODEL CONTROLLER. MOUNT CONTROLLER IN

OUTDOOR MECHANICAL AREA OF BUILDING PER MFGS.

RECOMMENDATION. CONTROLLER SHALL BE HARD-WIRED TO

GROUNDED 110 VAC SOURCE. CONTROLLER TO BE

EQUIPPED AND INCLUDE HANDHELD KIT.

3/4" POWER SUPPLY CONDUIT

J BOX INSIDE CONTROLLER

CONNECT PER LOCAL CODE

VSR DesignLandscape Architecture-Planning-Sports-Recreation

P.O. Box 7608Overland Park, KS 66207ph: (913) 484-5211

Kaw Valley Engineering, Inc.Survey & Civil14700 W. 114th TerraceLenexa, KS 66215ph: (913) 894-5150

Smith & Boucher, Inc.Electrical Engineering25501 Valley Parkway, Suite 200Olathe, KS 66061ph: (913) 344-0029

01.08.19

SCALE

1" =

0

FEET

PF 3.01

TRACK

IRRIGATION

20'-0"

20' 20'

SCALE

1" =

0

FEET

20'20'

20'-0"

IRRIGATION NOTES LEGEND

2

3

GENERAL NOTES

1. DESIGN IS BASED ON A MINIMUM FLOW OF 60 GPM AND PRESSURE

OF 70 PSI AT THE POINT OF CONNECTION.

2. MINIMUM PRESSURE AT FARTHEST HEAD SHALL BE A MINIMUM OF 50

PSI.

3. SUPPLY AND INSTALL A BOOSTER PUMP MFG. MUNRO MODEL LP100B

WITH POWDER COATED STAINLESS STEEL ENCLOSURE. POUR 4"

CONCRETE PAD TO SET PUMP AND ENCLOSURE UNIT.

4. SPRINKLER LOCATIONS ARE TO SCALE. PIPE LOCATIONS ARE

DIAGRAMMATIC. CONSULT WITH LANDSCAPE ARCHITECT IF

CONSTRUCTION VARIES A GREAT DEAL FROM PLAN.

5. PROVIDE 2 QUICK COUPLING KEYS (1" MALE OUTLET) AND SH-2

SWIVEL HOSE ELL FOR EACH KEY.

6. ROUTE 2 SPARE WIRES FROM CONTROLLER AROUND ENTIRE MAIN

LINE LOOP. PROVIDE DIFFERENT COLOR OF WIRE FOR

IDENTIFICATION.

HUNTER HQ44RC QUICK COUPLING VALVE (1")

MANUAL SHUT-OFF VALVE

(SIZED AS SHOWN)

BACKFLOW PREVENTION DEVICE (DOUBLE CHECK)

MAINLINE PIPE: CLASS 200 PVC

(2.5-INCH SIZE)

LATERAL PIPE: CLASS 200 PVC

(SIZED AS SHOWN)

INDICATES CONTROLLER STATION NUMBER

INDICATES REMOTE CONTROL VALVE SIZE

INDICATES LATERAL DISCHARGE IN GPM

HUNTER I-25 W/ 07 NOZZLES

PRESSURE = 60 PSI RADIUS = 48 FT.

FLOW = 7.5 GPM

HUNTER ICC-2 IRRIGATION CONTROLLER

W/20 STATIONS, AND CAPABLE OF EXPANSION.

HUNTER ICV ELECTRIC REMOTE CONTROL VALVE

MASTER VALVE (ICV)MV

BOOSTER PUMP FURNISHED AND INSTALLED BYP

CONTRACTOR. MUNRO MODEL CP100B COMPLETE PRO II (VERIFY PRESSURE)

WITH A PUMP START IN A MUNRO PRESSURE START CONTROL BOX.

THE PUMP AND CONTROL BOX ELECTRICAL POWER IS 110V.

METER - EXISTINGM

1

POUR 4" CONCRETE PAD TO SET PUMP AND ENCLOSURE UNIT.

S

T

A

T

E

O

F M

I

S

S

O

U

R

I

VANCE S.

RZEPKA

NUMBER

LA-000144

vance rzepka
Text Box
220V
vance rzepka
Line
vance rzepka
Text Box
2
vance rzepka
Text Box
2
vance rzepka
Text Box
6" POPUP PLASTIC RISER.
vance rzepka
Text Box
2
vance rzepka
Text Box
1.24.19 ADD #2
vance rzepka
Text Box
METAL ENCLOSURE
vance rzepka
Text Box
2
vance rzepka
Text Box
vance rzepka
Pen
vance rzepka
Pen
vance rzepka
Pen
Page 6: Lakeview & Plaza Middle Schools Track Renovation Kansas ... · 5.provide 2 quick coupling keys (1" male outlet) and sh-2 swivel hose ell for each key. 6.route 2 spare wires from controller

REMOTE CONTROL VALVE

MODEL ICV - SIZE AS NOTED ON PLAN

FINISH GRADE

3/4" MINUS WASHED GRAVEL

BRICK SUPPORTS (4)

MAIN LINE PIPE &

FITTINGS

SCH 80 T.O.E. NIPPLE

STANDARD VALVE BOX

WATERPROOF CONNECTORS (2)

18-24" COILED WIRE

PVC SLIP UNIONS

CHRISTY ID TAG

LATERAL PIPE

LATERAL TEE OR ELL

MODEL I-25 ROTOR HEAD

PREFABRICATED SWING JOINT

FINISH GRADE

RUBBER COVER

CONTROL WIRE IN ELECTRICAL

CONDUIT. SIZE AND TYPE

PER LOCAL CODE

* NOTE:

18 STATION MODEL CONTROLLER. MOUNT CONTROLLER IN

OUTDOOR MECHANICAL AREA OF BUILDING PER MFGS.

RECOMMENDATION. CONTROLLER SHALL BE HARD-WIRED TO

GROUNDED 110 VAC SOURCE. CONTROLLER TO BE

EQUIPPED AND INCLUDE HANDHELD KIT.

3/4" POWER SUPPLY CONDUIT

J BOX INSIDE CONTROLLER

CONNECT PER LOCAL CODE

VSR DesignLandscape Architecture-Planning-Sports-Recreation

P.O. Box 7608Overland Park, KS 66207ph: (913) 484-5211

Kaw Valley Engineering, Inc.Survey & Civil14700 W. 114th TerraceLenexa, KS 66215ph: (913) 894-5150

Smith & Boucher, Inc.Electrical Engineering25501 Valley Parkway, Suite 200Olathe, KS 66061ph: (913) 344-0029

01.08.19

SCALE

1" =

0

FEET

PF 3.02

PLAY AREA

IRRIGATION

20'-0"

20' 20'

SCALE

1" =

0

FEET

20'20'

20'-0"

IRRIGATION NOTES LEGEND

2

3

GENERAL NOTES

1. DESIGN IS BASED ON A MINIMUM FLOW OF 60 GPM AND PRESSURE

OF 70 PSI AT THE POINT OF CONNECTION.

2. MINIMUM PRESSURE AT FARTHEST HEAD SHALL BE A MINIMUM OF 50

PSI.

3. SUPPLY AND INSTALL A BOOSTER PUMP MFG. MUNRO MODEL LP100B

WITH POWDER COATED STAINLESS STEEL ENCLOSURE. POUR 4"

CONCRETE PAD TO SET PUMP AND ENCLOSURE UNIT.

4. SPRINKLER LOCATIONS ARE TO SCALE. PIPE LOCATIONS ARE

DIAGRAMMATIC. CONSULT WITH LANDSCAPE ARCHITECT IF

CONSTRUCTION VARIES A GREAT DEAL FROM PLAN.

5. PROVIDE 2 QUICK COUPLING KEYS (1" MALE OUTLET) AND SH-2

SWIVEL HOSE ELL FOR EACH KEY.

6. ROUTE 2 SPARE WIRES FROM CONTROLLER AROUND ENTIRE MAIN

LINE LOOP. PROVIDE DIFFERENT COLOR OF WIRE FOR

IDENTIFICATION.

HUNTER HQ44RC QUICK COUPLING VALVE (1")

MANUAL SHUT-OFF VALVE

(SIZED AS SHOWN)

BACKFLOW PREVENTION DEVICE (DOUBLE CHECK)

MAINLINE PIPE: CLASS 200 PVC

(2.5-INCH SIZE)

LATERAL PIPE: CLASS 200 PVC

(SIZED AS SHOWN)

HUNTER I-25 W/ 07 NOZZLES

PRESSURE = 60 PSI RADIUS = 48 FT.

FLOW = 7.5 GPM

HUNTER ICC-2 IRRIGATION CONTROLLER

W/20 STATIONS, AND CAPABLE OF EXPANSION.

HUNTER ICV ELECTRIC REMOTE CONTROL VALVE

MASTER VALVE (ICV)MV

METER - EXISTINGM

1

INDICATES CONTROLLER STATION NUMBER

INDICATES REMOTE CONTROL VALVE SIZE

INDICATES LATERAL DISCHARGE IN GPM

BOOSTER PUMP FURNISHED AND INSTALLED BYP

CONTRACTOR. MUNRO MODEL CP100B COMPLETE PRO II (VERIFY PRESSURE)

WITH A PUMP START IN A MUNRO PRESSURE START CONTROL BOX.

THE PUMP AND CONTROL BOX ELECTRICAL POWER IS 110V.

POUR 4" CONCRETE PAD TO SET PUMP AND ENCLOSURE UNIT.

(ALTERNATE 1)

S

T

A

T

E

O

F M

I

S

S

O

U

R

I

VANCE S.

RZEPKA

NUMBER

LA-000144

vance rzepka
Text Box
6" POPUP, PLASTIC RISER
vance rzepka
Text Box
2
vance rzepka
Text Box
2
vance rzepka
Text Box
METAL ENCLOSURE
vance rzepka
Text Box
1.24.19 ADD #2
vance rzepka
Text Box
2
vance rzepka
Text Box
vance rzepka
Pen
vance rzepka
Pen
vance rzepka
Pen
Page 7: Lakeview & Plaza Middle Schools Track Renovation Kansas ... · 5.provide 2 quick coupling keys (1" male outlet) and sh-2 swivel hose ell for each key. 6.route 2 spare wires from controller

1

"

1

1

"

2

2

"

30.0

1

37.5

4

30.0

2

30.0

3

37.5

5

30.0

7

30.0

6

30.0

8

37.5

12

30.0

14

30.0

13

37.5

11

30.0

9

30.0

10

2

"

1

1

"

2

1

1

"

2

1

1

"

2

1

1

"

2

1

"

2

"

1

"

1

"

2

"

1

1

"

2

1

1

"

2

2

"

2

"

1

1

"

2

1

1

"

2

1

"

1

"

1

"

1

1

"

2

2

"

2

"

1

"

1

"

1

"

1

"

1

"

1

"

1

"

1

"

1

"

1

1

"

2

1

1

"

2

1

1

"

2

1

1

"

2

1

1

"

2

1

1

"

2

2

"

2

"

2

"

1

1

"

2

1

1

"

2

2

"

M

V

2

"

2

"

1

1

"

2

2

"

2

"

2

"

2

"

2

"

2

"

2

"

2

"

2

"

2

"

2

"

2

"

07

07

07

07

07

07 07

07

07

07

07

0707

07

07

07

07

0707

07

07

07

07

0707

07

07

07

07

0707

07

07

07

07

07 07

07

07

07

07

07 07

07

07

07

07

07

07

07

07

07

07

07 07

07

07

07

07

07

REMOTE CONTROL VALVE

MODEL ICV - SIZE AS NOTED ON PLAN

FINISH GRADE

3/4" MINUS WASHED

GRAVEL

BRICK SUPPORTS (4)

MAIN LINE PIPE &

FITTINGS

SCH 80 T.O.E. NIPPLE

STANDARD VALVE BOX

WATERPROOF CONNECTORS (2)

18-24" COILED WIRE

PVC SLIP UNIONS

CHRISTY ID TAG

LATERAL PIPE

LATERAL TEE OR ELL

MODEL I-25 ROTOR HEAD

PREFABRICATED SWING JOINT

FINISH GRADE

RUBBER COVER

CONTROL WIRE IN ELECTRICAL

CONDUIT. SIZE AND TYPE

PER LOCAL CODE

* NOTE:

18 STATION MODEL CONTROLLER. MOUNT CONTROLLER IN

OUTDOOR MECHANICAL AREA OF BUILDING PER MFGS.

RECOMMENDATION. CONTROLLER SHALL BE HARD-WIRED TO

GROUNDED 110 VAC SOURCE. CONTROLLER TO BE

EQUIPPED AND INCLUDE HANDHELD KIT.

3/4" POWER SUPPLY CONDUIT

J BOX INSIDE CONTROLLER

CONNECT PER LOCAL CODE

VSR DesignLandscape Architecture-Planning-Sports-Recreation

P.O. Box 7608Overland Park, KS 66207ph: (913) 484-5211

Kaw Valley Engineering, Inc.Survey & Civil14700 W. 114th TerraceLenexa, KS 66215ph: (913) 894-5150

Smith & Boucher, Inc.Electrical Engineering25501 Valley Parkway, Suite 200Olathe, KS 66061ph: (913) 344-0029

01.08.19

PF 3.01

FOOTBALL + TRACK

IRRIGATION

SCALE

1" =

0

FEET

20'20'

20'-0"

2

3

1

IRRIGATION NOTES LEGENDGENERAL NOTES

1. DESIGN IS BASED ON A MINIMUM FLOW OF 60 GPM AND PRESSURE

OF 70 PSI AT THE POINT OF CONNECTION.

2. MINIMUM PRESSURE AT FARTHEST HEAD SHALL BE A MINIMUM OF 50

PSI.

3. SUPPLY AND INSTALL A BOOSTER PUMP MFG. MUNRO MODEL LP100B

WITH POWDER COATED STAINLESS STEEL ENCLOSURE. POUR 4"

CONCRETE PAD TO SET PUMP AND ENCLOSURE UNIT.

4. SPRINKLER LOCATIONS ARE TO SCALE. PIPE LOCATIONS ARE

DIAGRAMMATIC. CONSULT WITH LANDSCAPE ARCHITECT IF

CONSTRUCTION VARIES A GREAT DEAL FROM PLAN.

5. PROVIDE 2 QUICK COUPLING KEYS (1" MALE OUTLET) AND SH-2

SWIVEL HOSE ELL FOR EACH KEY.

6. ROUTE 2 SPARE WIRES FROM CONTROLLER AROUND ENTIRE MAIN

LINE LOOP. PROVIDE DIFFERENT COLOR OF WIRE FOR

IDENTIFICATION.

HUNTER HQ44RC QUICK COUPLING VALVE (1")

MANUAL SHUT-OFF VALVE

(SIZED AS SHOWN)

BACKFLOW PREVENTION DEVICE (DOUBLE CHECK)

MAINLINE PIPE: CLASS 200 PVC

(2.5-INCH SIZE)

LATERAL PIPE: CLASS 200 PVC

(SIZED AS SHOWN)

INDICATES CONTROLLER STATION NUMBER

INDICATES REMOTE CONTROL VALVE SIZE

INDICATES LATERAL DISCHARGE IN GPM

HUNTER I-25 W/ 07 NOZZLES

PRESSURE = 60 PSI RADIUS = 48 FT.

FLOW = 7.5 GPM

HUNTER ICC-2 IRRIGATION CONTROLLER

W/20 STATIONS, AND CAPABLE OF EXPANSION.

HUNTER ICV ELECTRIC REMOTE CONTROL VALVE

MASTER VALVE (ICV)MV

METER - EXISTINGM

S

T

A

T

E

O

F M

I

S

S

O

U

R

I

VANCE S.

RZEPKA

NUMBER

LA-000144

6" POPUP PLASTIC RISER.

METAL ENCLOSURE

2

2

2 1.24.19 ADD #2