invensys upstream scada technology awareness
DESCRIPTION
A brief overview of Invensys SCADA TechnologyTRANSCRIPT
© 2010 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys are proprietary marks of Invensys or its subsidiaries. All third party trademarks and service marks are the proprietary marks of their respective owners.
© Invensys 00/00/00 Invensys proprietary & confidential
Invensys Upstream SCADA Technology Awareness
Master Stations and RTUsAugust 2012 Edition
Chris J SmithDirector
Remote Packaged Solutions
1 SCADASYSTEMS PRODUCT
COMPONENTS
FOXBORO SCADA PRODUCTS
Power RTU
• Transmission Level
Automation for high
voltage substations
© Invensys April 11, 2023Invensys proprietary & confidential
SCD2100 SCD2200SCD5200RTU50
Master Terminal Unit (MTU) ArchestrA SCADA software integrates the synchronization, comms, data propagation, security and failover functionality that geographically distributed SCADA systems demand
Well Head RTU
• Ultra Compact / extremely low power
• Class I Div 2 solution for limited I/O in very remote Oil & Gas
Production RTU
• Redundant / low power consumption
• Low- or high-density I/O, redundant CPU, power supplies, communication lines
AVAILABLE
Which SCADA Products does Invensys Offer ?
Master Stations [MTU] are software
based, which apply to either Unix
or Windows OS on Common Off the
Shelf Industrial Workstations and
Servers
• MTU include SCADA
Communications, List Management,
Engineering, Operator Workstation
Functions
•SCADA Specific Objects
•DNP Communications
ArchestrA SCADA Software
•Unix [Solaris]
•DNP / 104 Communications
IASCADA[Unix/Win]
•Unix [HP]
•DNP/P6008 Communications
P6009[Unix / Win]
•DNP / P6008 Communications
SCADA-A2 [obsolete]
Remote Terminal Units [RTU] are
scaled according to
performance and local
industry specific requirements
They use open SCADA protocols
for communications
SCD5200• Electric Power Focus [DNP/103/104]• Distributed Control in oil and gas
SCD2200•Oil and Gas Production Focus [DNP/P6008]•Modular Redundant , Low Power
SCD2100•Oil and Gas Well Focus [DNP], AGA, PID•Ultra Low Power, Class I Div II Locations
Slide 5
© Invensys
IA SCADA Program – Rev 9,
IASCADA 9.0 SCADA
Functions
• Retrospective History Storage on
Communications Restoration
• System Monitoring
• File Transfer Agent [IED Pass Through]
• New Supported Server H/W Solaris 10
• Sun T5120 Server
• Sun M-Series Servers
• Roadmap Direction
– Migration of Sammi Displays to [dot]Net format
ArchestrA System Platform
Engineering / SupportProductivity Tools
Wonderware HMI {InTouch}
Extensibility & Integration Toolkits
ArchestrA Unified Engineering Environment
Mapping Product Brands to the InFusion ECS
Operations Management Apps
3rd P
arty
Ap
plic
ation
s
3rd P
arty
Bu
sine
ss S
yste
ms
Systems
Equipment
3rd P
arty
D
evic
es
Foxb
oro
M&
I Dev
ices
Euro
ther
mD
evic
es
Invensys proprietary & confidential
Foxb
oro
DCS
Tric
onex
Sa
fety
Foxb
oro
RTU
s
Won
derw
are
MES
– E
MI –
Mob
ile
Skel
taW
orkfl
ow
Sim
Sci-E
ssco
rSi
mul
ation
Avan
tisAs
set M
anag
emen
t
SCADA Application
Wonderware Historian {InSQL}
Foxb
oro
CLS
Substation Automation Configurator
IEC61850 Runtime
Foxb
oro
PAC
Ecka
rtdt
M&
I Dev
ices
Common Engineering withProcess Control
Alignment with Foxboro PAC
Windows 7/8System Platform 2012
Better Graphics ManagementArchestrA Graphics
Disaster RecoveryTiered Historian
Technical Objectives – ArchestrA SCADA Software
Better DNP performanceSOE and Engine Performance
ArchestrA SCADA Software 2012Release Themes
• Build a new Console based on new ArchestrA Navigation
• Incorporate CyberSecurity Features
• Transition SCADA Core to a separable Module
• Build a runtime environment for IEC 61850
• Provide Migration Path for existing Technology• SCADAPAK
• SCADA-A2
• IASCADA V7
Slide 9
Jan 2010
Mar2010
May2010
Oct2010
April2011
InTouch 10.1 SP2
AppServer
3.1 SP2
InTouch 10.1 SP2
Patch 01
AppServer
3.1 SP2 Patch
01
InTouch 10.1SP3P1
AppServer
3.1SP3P1
InTouch 10.1 SP3
AppServer
3.1 SP3
InformationServer
4.0
Tech Update
Maintenance Maintenance
Previous Platform Releases
InFusion SCADA
2.1
InFusion SCADA
SP1
InFusion SCADA 2.1 SP2
Aug2011
Oct2011
InFusion SCADA 2.1 SP3
Jan 2010
Mar2010
May2010
Oct2010
April2011
InTouch 10.1 SP2
AppServer
3.1 SP2
InTouch 10.1 SP2
Patch 01
AppServer
3.1 SP2 Patch
01
InTouch 10.1SP3P1
AppServer
3.1SP3P1
InTouch 10.1 SP3
AppServer
3.1 SP3
InformationServer
4.0
InFusion SCADAComponent
Previous Platform Releases – IEC 61850
IEC61850 ObjectsInitial Release
Aug2011
Oct2011
Substation Automation Configurator
SAC 1.0[IEC61850]
IDE Application
FOXBORO SCADA PRODUCTS – KEY FEATURES
DISTRIBUTED
• NODAL
ARCHITECTURE
• HIGH ISOLATION
• HIGH NOISE IMMUNITY
• SALL USER ENV.
• HIGH CONNECTION
SECURITY
© Invensys April 11, 2023Invensys proprietary & confidential
SCD2100 SCD2200SCD5200RTU50
COMPACT
• SIMPLEX
• ONBOARD BATTERY
POWER MANAGEMENT
• VERY LOW POWER
• VERY COMPACT
• CLASS 1 DIV 2 Environ
MODULAR
• REDUNDANT
• Expandable
• PLC FUNCTIONAL
PROGRAMMIING
• IsaGraf based
• Function Library
RTU Architectures
Slide 13
MTU [a] MTU [b] MTU [a] MTU [b]
Distributed Nodal RTU
Multi-SiteTime Synchronised
RTUs
Typical for Oil and Gas, Water, Municipal
Architectures
Typical for HV Electric Power
NetworksComplex Oil and Gas Distributed
Applications
Mix of serial, TCP/IP Protocols over open public communications
media
DNP, IEC 60870-101,104
IEC61850 Networks
New Standard for Substation
Automation and Measurement
3SCD5200Distributed Solutions
EXAMPLE UPSTREAM WELL APPLICATION
Instrument AMS
IASCADA or ArchestrA SCADA• DNP Communications Protocol
facilitates
– RTU Hardware Migration
– SCADA Platform Migration
– Pass Through Communications
– File Transfer
– Well Test
– Secure Control
Slide 15
DNP3[Communications Protocol]
SCD2200
HARTVia Imbedded
Modem
SCD5200
HARTVia
Multiplexor
Field Instruments
RTU50/SCD5200 Continuously Current Hardware Technology
Common CPU for RTU processors
Common CPU for Communications
Processors
Common Operating System and Tools
Common configurable IO processing for
signal level IO
Specialized modules for high voltage IO
Full range of Device Integration and
Intelligent IO Bus Handling
Certified IEC 61850 Substation Automation
Services
Secure Authorized Connectivity Services
Optonet ring
Common CoreDNP Security
IEC 61850 GatewayIEC 61850
Continuously CurrentNew Chip Technology
QualityCertification
Technical Objectives – Foxboro SCD5200/R50 RTUs
Next GenerationWindows 7
RTU50 / SCD5200 Update
YEAR Classic
Protocols
Bus Type
Protocols
Remote
Terminal
Viewer
System
Configurat
or
ArchestrA
IDE
SCD5200 Security
Configurator
2012 Sustain IEC 61850
Stack / Schema update
Windows 7 Compatibility
2013 Maintenance of Line – Foundation Level
2014 Maintenance of Line – Foundation Level
Note Modbus,
DNP,
Conitel
All releases are
3rd Party Certified
for IEC 61850
Compliance
Security File
Management
IEC61850
Diagnostics
Standard
product
Configurator
IEC 61850
Specification
and open
Configuration
NEW PRODUCT to
provide Security in the
SCD5200
4SCD2200Redundant Solutions
Slide 20
SCADA RTU’s – SCD2200
• FoxRTU Station programming software based on ISaGRAF
• Two Components within Fox RTU StationConfigurationISaGRAF• Integration with System Platform – Next part of the
strategy
Fox RTU Station
SCADA RTU
• Scalable I/O, up to 1000 points• Redundant CPU Option• Multiple “open” protocols including DNP3, Modbus, Allen Bradley DF1, SNMP,• AGA and Foxboro Specific Function Blocks• Support for multiple communications media including Ethernet, Fiber, Leased Line,
V34 PSTN modem and Isolated Serial (RS232/422/485), HART• Store & Forward• IEC 61131 Applications• Operating temperature to 70oC• Communications Media as OPTION Boards
Common Engineering withProcess Control
Bulk .Net based config. control
Higher Density IOFaster AD Conversion
Secure ProtocolsPlug and Play
DNP Security, Capability
HART Module Pass Through
HART 5 Standard
Technical Objectives – Foxboro SCD2x00 RTUs
Better Integration of Control Applications
High Performance Redundancy
IO5 IO Module – Long Life
IO3 Module
• 4 Digital In
• 4 Digital Out [2A
Relay]
• 4 Analog In
• 1 Analog Out
IO5 Module
• 4 Digital In [10KHz counters on each input]
• 4 Digital Out [Electronic Switch [30V, 5A]]
• 4 Analog In
• 1 Analog Out [Open Loop Detection]
Life was limited due to average max relay contact closures.
Removes the need for a dedicated input module for high speed counters, and provides a robust pulse output feature
Consistent Analog Output treatment with the RTU20 and the AO3 Module
SCD2200 – MC-31
• MC-31 [MC-3Upgrade]
• T3 Enet Option Board
June 2011 AUGUST 2012
Calendar year
23
SCD2200 – 3.0 – Current Version
SAME functions as SCD2200 2.0
April 2011
SCD2200
• New Superior 60W Power Supplies:
PS12, PS22
These obsolete the 30W [PS11,PS21]
SCD2200 - Mercury
• DNP 3 Pass Through• NTP• DNP3 Master (both
serial and ethernet)• Security
autentication for DNP3 Master / Slave
• Message routing control into IsaGraf.
• P6008 slave base protocol (no sequence)
• IO5 Mixed I/O Module
MAR 2013
5SCD2100Point Solutions
SCD2100 – Compact “Well Head RTU”• Industry: Oil/Gas; Water; • Low Power 2.5W + Digital Card• Intrinsic Safety C1, Div 2, Grp 1• Temp Spec +70C to -20C• 6.9”H x 2.8”W x 5”D• 120VAC , 12VDC• Backup Batt Charger• Modbus Master/Slave• DNP3 slave, SNMP
(request/reply)• API toolkit for others• Control functionality 61131• 3 IO Card choices
─ #1 14 DI; 8DO; 6AI─ #2 14 DI; 8DO; 6AI; 2AO─ #3 16 DI; 16DO
Thank you !!!
For your time.
I hope you enjoyed my presentation.
I would like to open the microphone for questions.
If you would have questions please contact us.