Page 1: Invensys MicroNet Remote Alarm Manager for MicroNet

Invensys MicroNetInvensys MicroNet

Remote Alarm Manager for MicroNet

Page 2: Invensys MicroNet Remote Alarm Manager for MicroNet

Integrated Remote Alarm Manager

Why let the BMS systems limit your freedom?

Use Remote Alarm Manager to make your system provide relevant information reliably

when you want where you want.

Is your operations’ efficiency maximised?

Have you ever wondered when you are away -“Is my plant working OK?” -“Is my alarming system working OK?Are your customers complaining about the system operation? Would an early warning have enabled you to rectify problems before they are noticed?

Page 3: Invensys MicroNet Remote Alarm Manager for MicroNet

-knows when you want information-knows where you want information to be sent-knows what information you want -tracks that you get information securely, or re-routes it to the back-up locations when necessary- monitors your BMS system and alarm notification system maximising the messaging reliability

Integrated Remote Alarm Manager

Remote Alarm Manager

HomeHome

OfficeOffice

Out & AboutOut & About

FactoryFactory

Remote Alarm Manager Messaging System

PlantPlant

MobileMobilePhonePhone

FaxFax

PC or PC or LaptopLaptop

Mobile Mobile OrganisOrganiserer

Page 4: Invensys MicroNet Remote Alarm Manager for MicroNet

Flexible Information Delivery

Remote Alarm Manager Provides

• Total flexibility- Information at right time- Right information, only what you need to know- Right Place – information is transferred to remote

location, wherever and whenever you require it- Wide range of drivers to suit your requirements

Kernel

GSMTAP/UCP

EMAILFAX PRINTERWAP WEB

Duty Schedule Logic engine

CONSOLE

SMS via SMS via direct direct GSM GSM connectioconnectionn(2-way)(2-way)

SMS via SMS via UCP or UCP or TAPTAP(1-way)(1-way)

FAXFAXEmailEmail

WAPWAP Web-BrowserWeb-Browser

Laser and Laser and Dot Matrix Dot Matrix PrintersPrinters

Remote PC Remote PC ConsolesConsoles

Page 5: Invensys MicroNet Remote Alarm Manager for MicroNet

Secure Information

Remote Alarm Manager Provides

• Secure Information Access and Delivery- Windows user authentication option for Console Application and

Web-clients - Flexible rule sets for mobile users for setting right levels of

security- Tracks message receipt and retransmits until successfully

delivered- Built-in event logging - full traceability of events- Self-diagnostics, watchdog functionality checks that the system,

the interfaces and the source systems are operationalExtremely reliable information delivery

- high priority alarms get through preventing and minimising the damages and losses

- ‘after event analyses’ improve the operational efficiency

Page 6: Invensys MicroNet Remote Alarm Manager for MicroNet

Scalability and Extensibility

• Easy to handle system configuration from small to large sites– Seamless integration to MicroNet View– Single-click configuration– If it is not relevant – hide it– Configuration time in minutes

Remote Alarm Manager provides

• Flexibility and power enough for large and complex configurations– Complete control through scripting– Extremely flexible rule sets – “if you can think it you can do it”

• Extensibility using Drivers– Design is based on installable drivers (easy on-site upgrade)– New driver development possible e.g. duty planner integration to

Outlook, or generic input driver

Page 7: Invensys MicroNet Remote Alarm Manager for MicroNet

Ease of Installation

• Ease of Installation- No expert operating system knowledge required- Everything is built-in (WEB/WAP server)- One software CD contains all you need

Remote Alarm Manager Provides

• Ease of Configuration– Integrates seamlessly to MicroNet alarm database, no duplicate

configuration– Inherit alarm properties– Integrates with user access control– Uses same copy protection– Two-way information flow

– Auto-detection wherever possible (e.g. GSM Modems)– Configured very easily through Wizards– Single-click choices- Automated test routines minimise the configuration time and prove

the operation - Offer solutions, not waste your time in configuration

Page 8: Invensys MicroNet Remote Alarm Manager for MicroNet

Kernel(Windows Service)GSM

TAP/UCP

EMAILFAX

PRINTERWAP WEB

Duty Schedule

Logic engine

CONSOLE

SMS via direct SMS via direct GSM GSM connectionconnection(2-way)(2-way)

SMS via SMS via UCP or UCP or TAPTAP(1-way)(1-way)

FAXFAX

EmailEmail WAPWAPWeb-BrowserWeb-Browser

Laser and Laser and Dot Matrix Dot Matrix PrintersPrinters

Remote PC Remote PC ConsolesConsoles

Host Interface(Windows Service)

SIMULATE

SMS

SMS SMS Simulator Simulator (for demos)(for demos)

Modular Extensible Structure

MicroNet

MN MonitorTool

I/O-servers

WindowViewerAlarms Log

s

MICRONET VIEW MICRONET VIEW INTEGRATIONINTEGRATION- Reads and acknowledges Reads and acknowledges alarms remotely in the alarms remotely in the Monitor Tool DBMonitor Tool DB- Watchdog functionality Watchdog functionality checks that application is checks that application is runningrunning

Page 9: Invensys MicroNet Remote Alarm Manager for MicroNet

Simulate SMS

• Simulate Nokia 6210 on screen– Receive SMS from Mercury– Send SMS back to Mercury

• Demos– Very realistic

• Commissioning– Test alarms without sending real SMS

Page 10: Invensys MicroNet Remote Alarm Manager for MicroNet

SMS via GSM modem

• Send and receive SMS – High throughput (10 msg./min), very reliable– Transmits messages directly into mobile network

• Uses dedicated hardware– Commands defined by ETSI organisation– Most mobile phones (demo only)– Industrial type HW (Siemens, Brodersen)– Plugs into serial port– Requires mobile subscription

• All countries that support GSM

Page 11: Invensys MicroNet Remote Alarm Manager for MicroNet

SMS via UCP service

• Send SMS– Dial-in to central service– UCP (Universal Computer Protocol)– Uses Windows modem driver (TAPI)

• Countries– Belgium, Denmark, Germany, Finland, Iceland, Netherlands, (Norway),

Portugal, Spain, (Sweden), Switzerland

Page 12: Invensys MicroNet Remote Alarm Manager for MicroNet

SMS via TAP service

• Send SMS– Dial-in to central service– TAP (Telocator Alphanumeric Protocol)– Uses Windows modem driver (TAPI)

• Countries– Austria, Australia, Belgium, Canada, Germany, Iceland, Ireland, Netherlands,

New Zealand, (Norway), Switzerland, United Kingdom, United States of America

Page 13: Invensys MicroNet Remote Alarm Manager for MicroNet

Printer

• Send alarm messages to a printer– Uses Windows Printing Services– Local or network printing– Line printer (dot-matrix)– Page printer (laser or jet-ink)– Completion of print job is monitored

• Treat printer as a recipient– Can be on/off duty

Page 14: Invensys MicroNet Remote Alarm Manager for MicroNet

FAX

• Send alarm messages to a fax– Uses Microsoft Windows Fax Services– Completion of fax job is monitored

• Treat fax as a recipient– Can be on/off duty

Page 15: Invensys MicroNet Remote Alarm Manager for MicroNet

Duty Schedule

• Simple week based duty schedule– Multiple users on duty at the same time– One user on duty one week at the time

Page 16: Invensys MicroNet Remote Alarm Manager for MicroNet

WEB

• WEB browser client– Review messages– Review active alarms– Review interface status– Review users on duty– 100% HTML based

• Everything is built in– Does not require Microsoft IIS or Java runtime– No additional licences or fees

Page 17: Invensys MicroNet Remote Alarm Manager for MicroNet

WAP

• WAP 1.1 client– Review, acknowledge messages– Review active alarms– Review interface status– Review users on duty

• Everything is built in– Does not require Microsoft IIS or Java runtime– No additional licences or fees– Uses public WAP gateway

Page 18: Invensys MicroNet Remote Alarm Manager for MicroNet

Remote alarm manager

• Provides flexibility of delivering right message to the right place at the right time

• Provides comprehensive message tracking and user authentication system to guarantee security and reliability

• is extremely easy to configure, and is suitable from small site to the large complex systems

• uses latest software technology and is easily extensible with new drivers

Summary

Use Remote Alarm Manager to make your system provide relevant information reliably

when you want where you want.

Use Remote Alarm Manager to make your system provide relevant information reliably

when you want where you want.

Page 19: Invensys MicroNet Remote Alarm Manager for MicroNet

Thank youThank youfor your attention.for your attention.

Page 20: Invensys MicroNet Remote Alarm Manager for MicroNet