internal cryomodule instrumentation erl main linac cryomodule 10/10/2015 peter quigley, mlc design...

6
Internal Cryomodule Instrumentation ERL Main Linac Cryomodule 06/23/22 Peter Quigley, MLC Design Review

Upload: ashlyn-beasley

Post on 12-Jan-2016

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Internal Cryomodule Instrumentation ERL Main Linac Cryomodule 10/10/2015 Peter Quigley, MLC Design Review

Internal Cryomodule Instrumentation

ERL Main Linac Cryomodule

04/21/23

Peter Quigley, MLC Design Review

Page 2: Internal Cryomodule Instrumentation ERL Main Linac Cryomodule 10/10/2015 Peter Quigley, MLC Design Review

04/21/23 Peter Quigley, MLC Design Review

Input Couplers and 80K Shield not shown

300K

≤ 2K

Cavity Helium Vessel

Gate Valve

HOM Load

Support Post

HGRP

SC Magnet

2K 2-Phase LineBPM

Gate Valve

MLC Basic Thermal Map

Page 3: Internal Cryomodule Instrumentation ERL Main Linac Cryomodule 10/10/2015 Peter Quigley, MLC Design Review

HOM Load

40K Flange:Gas Input

04/21/23Peter Quigley, MLC Design Review

Cavity, Helium Vessel, Input Coupler, HOM LoadUnit Sensor Layout

Cavity Helium Vessel

Cavity Field Probe Port (2)

Input Coupler

Input Coupler 5K Intercept: Gas Input

Input Coupler Cooling Gas Input/Output

CERNOX 1050-SD

CLTS

PT1000

HOM LoadAdjacent Cavity /Coupler

300K

≤ 2K

Page 4: Internal Cryomodule Instrumentation ERL Main Linac Cryomodule 10/10/2015 Peter Quigley, MLC Design Review

Sensor Layout For Cryogenics Piping

2K 2-Phase Line

HGRP

CERNOX 1050-SD

CLTS

PT1000

80K return

6.5K return

40K delivery

5K forward

5K local

40K forward

40K local

Peter Quigley, MLC Design Review04/21/23

*Use of a pressure sensor for flow detection is being considered.

Pressure Sensor

*

*

300K

≤ 2K

Page 5: Internal Cryomodule Instrumentation ERL Main Linac Cryomodule 10/10/2015 Peter Quigley, MLC Design Review

04/21/23 Peter Quigley, MLC Design Review

• CERNOX 1050-SD RTD (300K to 1.6K).• CLTS (Cryogenic Linear Temperature Sensor) (300K to 4K).• PT1000 RTD (450K to 40K).• Liquid Helium Level Sensor: 2K type, cold feedthrough.• SC Quad: Lead wire feedthrough LHC type or similar.• Piezo sense and actuator: Noliac, tested in HTC-I,II, and III.• Tuner Motor: Cold, tested in HTC-I,II, and III.• Heaters:

• One heater per helium vessel mounted on 2K 2Phase Line.

• Two heaters per HOM load, 200W each.

• Vacuum Monitoring and Control: Open for discussion.• RF cable: Semi-rigid or Flexible coax.

General Instrumentation Information

Page 6: Internal Cryomodule Instrumentation ERL Main Linac Cryomodule 10/10/2015 Peter Quigley, MLC Design Review

HOM Load

40K Flange: Gas Input

04/21/23Peter Quigley, MLC Design Review

Cavity, Helium Vessel, Input Coupler, HOM LoadAdditional Sensor Layout For Prototype

Cavity Helium Vessel

Cavity Field Probe Port (2)

Input Coupler

Input Coupler 5K Intercept: Gas Input

Input Coupler Cooling Gas Input/Output

HOM LoadAdjacent Cavity /Coupler

CERNOX 1050-SD

CLTS

PT1000

300K

≤ 2K