Basis Data Shape = Rectangular Material = Silicone Coated Fabric Carbon Steel = 230 = 27 Insulation = Cellular Glass Foam = 55 Calculation = 175 Temperature difference between operating temperature and insulation surface = 28 Temperature difference between insulation surface temperature and ambient te = 142.5 Average temperature of the shape Q = 300 Heat losses Refer to fig 6.15a GPSA Sect 6 = 0.55 Required thermal resistance of insulation Refer to fig 6.15b GPSA Sect 7 For insulation material : Cellular Glass Foam ASTM C-552-79 Class 1 A = 0.3488 Refer to fig 6.14 GPSA Sect 6 B = 5.04E-04 Refer to fig 6.14 GPSA Sect 6 C = 1.14E-07 Refer to fig 6.14 GPSA Sect 6 D = 7.17E-10 Refer to fig 6.14 GPSA Sect 6 k = 7.51E-02 = 0.04 m = 41.3 mm Required insulation thickness for flat surface Shape = Cylinder Size = 100 mm OD Orientation = Vertical = 30 mm Refer to fig 6.15c GPSA Sect 6 OD - including insulation - = 160 mm Q/L = 150.72 W/linear m Orientation = Horizontal Orientation Factor = 1.35 Refer to GPSA Sect 6 = 37.8 Refer to fig 6.15a GPSA Sect 6 = 0.375 Required thermal resistance of insulation Refer to fig 6.15b GPSA Sect 7 = 0.03 m 28.2 mm Operating temperature (TH) o C Ambient temperature (TA) o C Maximum insulation surface temperature (TS) o C DTI o C DTF o C TM o C W/m 2 RI XF XC Corrected DTF o C RI XF

Upload: zamijaka

Post on 23-Nov-2015

70 views

Category:

Documents


3 download

DESCRIPTION

insulation thickness

TRANSCRIPT

Insulation CalcBasis DataShape=RectangularMaterial=Silicone Coated Fabric Carbon SteelOperating temperature (TH)=230oCAmbient temperature (TA)=27oCInsulation=Cellular Glass FoamMaximum insulation surface temperature (TS)=55oCCalculationDTI=175oCTemperature difference between operating temperature and insulation surface temperatureDTF=28oCTemperature difference between insulation surface temperature and ambient temperatureTM=142.5oCAverage temperature of the shapeQ=300W/m2Heat lossesRefer to fig 6.15a GPSA Sect 6RI=0.55Required thermal resistance of insulationRefer to fig 6.15b GPSA Sect 7For insulation material : Cellular Glass Foam ASTM C-552-79 Class 1A=0.3488Refer to fig 6.14 GPSA Sect 6B=5.04E-04Refer to fig 6.14 GPSA Sect 6C=1.14E-07Refer to fig 6.14 GPSA Sect 6D=7.17E-10Refer to fig 6.14 GPSA Sect 6k=7.51E-02XF=0.04m=41.3mmRequired insulation thickness for flat surfaceShape=CylinderSize=100 mm ODOrientation=VerticalXC=30mmRefer to fig 6.15c GPSA Sect 6OD - including insulation -=160mmQ/L=150.72W/linear mOrientation=HorizontalOrientation Factor=1.35Refer to GPSA Sect 6Corrected DTF=37.8oCRefer to fig 6.15a GPSA Sect 6RI=0.375Required thermal resistance of insulationRefer to fig 6.15b GPSA Sect 7XF=0.03m28.2mm

ReffGPSA Sect 6GPSA Sect 6GPSA Sect 6GPSA Sect 6GPSA Sect 6