innova g2 t series - centralion · innova g2 t series 1k/2k/3k/1kl/2kl/3kl online ups typical...

42
Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE True double-conversion design with high adaptability to harsh mains conditions Output power factor 0.9 DSP design enables precise and reliable control Compact size and ideal solution for Kiosk backup power High efficiency results in energy saving Programmable LCD display Recharge to 90% battery capacity within 4 hours USB HID enable communication without software Desktop PC Ac mains Office devices Kiosk

Upload: dinhnhan

Post on 26-Jan-2019

277 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Innova G2 T series1K/2K/3K/1KL/2KL/3KL

Online UPS

Typical Application

KEY FEATURE

• True double-conversion design with high adaptability to harsh mains conditions

• Output power factor 0.9

• DSP design enables precise and reliable control

• Compact size and ideal solution for Kiosk backup power

• High efficiency results in energy saving

• Programmable LCD display

• Recharge to 90% battery capacity within 4 hours

• USB HID enable communication without software

Desktop PC

Ac mains

Office devicesKiosk

Page 2: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model InnovaG2 1K

InnovaG2 1KL

InnovaG2 2K

InnovaG2 2KL

InnovaG2 3K

InnovaG2 3KL

Capacity 1000VA/900W 2000VA/1800W 3000VA/2700W

Input

Input Voltage Range 100 ~ 300 VAC

Frequency Range 45 Hz– 55 Hz/54 Hz – 66 Hz

Input Wiring Single phase with ground

Current Distortion (THDi) <5% (typical) @ 100% linear load

Output

Output Power Factor 0.9

Nominal Output Voltage 220/230/240VAC

Voltage Regulation ±2 %

Frequency Range (Battery Mode) 50 / 60 ± 0.05Hz

Current Crest Ratio 3:1

Voltage Distortion (THDv) < 1% @ linear load, < 5%@ non-linear load

Output Waveform Pure sine wave

Parallel Operation N/A

EfficiencyInverter Mode >88% >90% >90%

ECO Mode >97%

Battery

Battery Type 12V / 9Ah N/A 12V / 9Ah N/A 12V / 9Ah N/A

Number of Internal Battery 2 N/A 4 N/A 6 N/A

Rated Battery Voltage 24V 48V 72V

Backup Time (@ Full Load) > 3.5min N/A > 3.5min N/A > 3.5min N/A

Recharge Time (to 90%) 4 hour N/A 4 hour N/A 4 hour N/A

Charging Current 1A 6A 1A 6A 1A 6A)

Transfer TimeBattery Mode ↔ Inverter Mode 0ms

Inverter Mode ↔ Bypass Mode 4ms (typical)

Display Programmable LCD

Audible Alarm Yes

Dimension WxHxD 144x229x345mm 102x229x345mm 190x330x393 m 102x330x393mm 190x330x393mm 102x330x393mm

Net Weight 9.4 kg 3.7 kg 17 kg 5.4 kg 22.2 kg 5.4 kg

EnvironmentOperating Temperature 0~40 °C

Noise Level 50dB @1 meter

Interface

USB Yes

Communication Slot Optional

Emergency Power Off Yes

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 3: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Typical Application

Innova I2 T series1KL/2KL/3KL

Online UPS

KEY FEATURE

• True double-conversion with OVCD (Over voltage Cut-off Device) design adapt to harsh utility environment

• 8A charger current minimize recharge time in poor electricity capacity application

• DSP design enables precise and reliable control

• Compact size and ideal solution for Kiosk backup power

• High efficiency results in energy saving

• Easy understanding programmable LCD display

• USB HID provide easy communication and avoid software installation

• BIS certified

Desktop PC

Ac mains

Office devicesKiosk

Page 4: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Model Innova I2 1KL Innova I2 2KL Innova I2 3KL

Capacity 1000VA/800W 2000VA/1600W 3000VA/2400W

Input

Input Voltage Range 100 ~ 300 VAC

Frequency Range 45 Hz– 55 Hz/54 Hz – 66 Hz

Input Wiring Single phase with ground

Current Distortion (THDi) <5% (typical) @ 100% linear load

Output

Output Power Factor 0.8

Nominal Output Voltage 220/230/240VAC

Voltage Regulation ±2 %

Frequency Range ( Battery Mode ) 50 / 60 ± 0.05Hz

Current Crest Ratio 3:1

Voltage Distortion (THDv) < 2% @ linear load, < 7%@ non-linear load

Output Waveform Pure sine wave

Parallel Operation N/A

EfficiencyInverter Mode >88% >90% >90%

ECO Mode >97%

Battery

Number of Internal Battery N/A N/A N/A

Rated Battery Voltage 36V 72V 96V

Charging Current 8A 8A 8A)

Transfer TimeBattery Mode ↔ Inverter Mode 0ms

Inverter Mode ↔ Bypass Mode 4ms (typical)

Display Programmable LCD

Audible Alarm Yes

Dimension WxHxD 102x229x345 mm 102x330x393mm 102x330x393mm

Net Weight 3.7 kg 5.4 kg 5.4 kg

EnvironmentOperating Temperature 0~40 °C

Noise Level 50dB @1 meter

Interface

USB Optional

RS232 Yes

Communication Slot Optional

Emergency Power Off Optional

Specification

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 5: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

6K/10KInnova series

Online UPS

KEY FEATURE

• True double-conversion design with high adaptability to harsh mains conditions

• DSP design enables precise and reliable control

• High output power factor (0.9)

• High efficiency results in energy saving

• Precise output voltage regulation

• Supports energy-saving ECO mode

• Intelligent communication slot enables remote monitoring

• LCD display shows easy-to-understand operational status

• Supports up to 4-unit parallel operation

Ac mains/Generator

Health care TelecomNetworkequipment

Financial Work station

Typical Application

Page 6: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model Innova 6K Innova 6KS Innova 10K Innova 10KS

Capacity 6000VA/5400W 10000VA/9000W

Input

Input Voltage Range 110~276VAC

Frequency Range 45-55Hz / 54-66Hz

Input Wiring Single phase with ground

Current Distortion (THDi) <5% @ full R load

Output

Output Power Factor 0.9

Nominal Output Voltage 2081/220/230/240VAC

Voltage Regulation ± 1 %

Frequency Range ( Battery Mode ) 50/60 ± 0.05 Hz

Current Crest Ratio 3:1

Voltage Distortion (THDv) <2% @ Linear Load, <5% @ Non-Linear Load

Output Waveform Pure Sine Wave

Parallel Operation Up to 4 units

Efficiency

Inverter Mode >92%

Battery Mode >92%

ECO Mode >96%

Battery

Battery Type 12V/7Ah N/A 12V/9Ah N/A

Number of Internal Battery 20 N/A 20 N/A

Rated Battery Voltage 240VDC

Backup Time (@ full load) > 5min N/A > 4 min N/A

Recharge Time (to 90%) 5 hour N/A 5 hour N/A

Charging Current 1.4A 4A 1.4A 4A

Transfer Time

Battery Mode ↔ Inverter Mode 0ms

Inverter Mode ↔ Bypass Mode 0ms

ECO Mode ↔ Battery Mode 10ms

Display LCD

Audible Alarm Yes

Dimension WxHxD 260 x 708 x 550 mm

Net Weight 80 kg 25.5 kg 84 kg 29.5 kg

EnvironmentOperating Temperature 0-45° C

Noise Level ≤50dB @ 1 Meter

Interface

RS232/USB RS23: optional, USB: standard

External Slot Yes

Emergency Power Off Yes

Note:1. 208VAC will be subject to 90% output derating

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 7: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Innova Combo series10K/20K

Online UPS

KEY FEATURE

• True double-conversion design to deal with harsh mains conditions

• High output power factor (0.9)

• Precise output voltage regulation

• Wide AC input voltage range

• Supports both 1-phase and 3-phase AC input

• Supports energy-saving ECO mode

• Two Intelligent communication slots and one RS232 port

enable up to 3 channels remote monitoring

• Supports parallel connection for up to 4 unitsTypical Application

Precision equipment

TelecomData center Network equipment

Ac mains/Generator

Page 8: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model Innova Combo 10K Innova Combo 20K

Capacity 10000 VA/ 9000W 20000VA/18000W

Input

Input Voltage Range 110-276VAC (Single Phase Input)190-478VAC (Three Phase Input)

Frequency Range 45Hz ~ 55Hz / 54Hz ~ 66Hz

Input Wiring Single Phase with Ground (L-N-G) /Three Phase with Ground (R-S-T-N-G)

Current Distortion (THDi) < 5% @ full R load

Output

Output Power Factor 0.9

Nominal Output Voltage 2001/208/220/230/240VAC

Voltage Regulation ± 1 %

Frequency Range ( Battery Mode ) 50/60 ± 0.05 Hz

Current Crest Ratio 3:1

Voltage Distortion (THDv) <2% @ Linear Load, <5% @ Non-Linear Load

Output Waveform Pure Sine Wave

Parallel Operation Up to 4 units

Efficiency

Inverter Mode >93%

Battery Mode >93%

ECO Mode >97%

Battery

Battery Type 12V/9Ah

Number of Internal Battery 24x1 24x2

Rated Battery Voltage 288VDC 288 VDC

Backup Time (@ Full Load) >5 minutes

Recharge Time (to 90%) 3 hours 5 hours

Charging Current 2A 4A

Transfer Time

Battery Mode ↔ Inverter Mode 0ms

Inverter Mode ↔ Bypass Mode 0ms

ECO Mode ↔ Battery Mode <10ms

Display LCD

Audible Alarm Yes

Dimension WxHxD 350 x 890 x 650 mm

Net Weight 115 kg 183 kg

EnvironmentOperating Temperature 0-45° C

Noise Level <55dB @ 1 Meter

Interface

RS232/USB Yes

External Slot Yes

Emergency Power Off Yes

Note:1. 200VAC will be subject to 90% output derating

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 9: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

1K/2K/3KInnova ISO series

Online UPS

KEY FEATURE

• True double-conversion design with high adaptability to harsh mains conditions

• Built-in input isolation transformer

• High efficiency results in energy saving

• Precise output voltage regulation

• Supports energy-saving ECO mode

• Intelligent communication slot enables remote monitoring

• LCD display shows easy-to-understand operational status

Typical Application

Desktop PC

Ac mains

Office devicesKiosk

Page 10: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model Innova ISO 1K Innova ISO 2K Innova ISO 3K

Capacity 1000VA/800W 2000VA/1600W 3000VA/2400W

Input

Input Voltage Range 120 ~ 264 VAC

Frequency Range 45-55 Hz/54-66 Hz

Input Wiring Single phase with ground

Current Distortion (THDi) <17% @ full load

Output

Output Power Factor 0.8

Nominal Output Voltage 220/230/240VAC

Voltage Regulation ±2 %

Frequency Range ( Battery Mode ) 50 / 60 ± 0.2Hz

Current Crest Ratio 3:1

Voltage Distortion (THDv) < 3% @ linear load, < 5%@ non-linear load

Output Waveform Pure sine wave

Parallel Operation N/A

Efficiency

Inverter Mode 80% 82% 83%

Battery Mode 85%

ECO Mode 93% 94%

Battery

Battery Type 12V / 7Ah 12V / 7Ah 12V / 9Ah

Number of Internal Battery 3 6 6

Rated Battery Voltage 36V 96V 96V

Backup Time (@ Full Load) > 5min > 5min > 3min

Recharge Time (to 90%) 5 hour 5 hour 5 hour

Charging Current 1A 1.5A 1.5A

Transfer Time

Battery Mode ↔ Inverter Mode 0ms

Inverter Mode ↔ Bypass Mode 4ms

ECO Mode ↔ Battery Mode <10ms

Display LCD

Audible Alarm Yes

Dimension WxHxD 190 X 356 X 383 mm 200 X 377 X 498 mm

Net Weight 22.5 kg 42 kg 54.6 kg

EnvironmentOperating Temperature 0~40 °C

Noise Level 52dB

Interface

RS232/USB Yes

External Slot Yes

Emergency Power Off Yes

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 11: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Ac mains/Generator

Health care TelecomNetworkequipment

Financial Work station

5K/6K/8K/11KInnova RT Premium series

Typical Application

Online UPS

KEY FEATURE

• True double-conversion on-line topology

• Ideal to for high-end equipment which are sensitive to power quality

• Multi language LCD and complete safety certificate support global distribution with minimum SKU.

• Tool-less battery replacement minimize battery replacement service complexity

• Integrated with the Network and software, allowing seamless integration into the industry-leading virtualization platforms

• Efficiency up to 95% in inverter mode

Page 12: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model 5KInnova RT Premium Innova RT Premium Innova RT Premium Innova RT Premium 6K 8K 11K

Capacity 5KVA/4.5KW 6KVA/5.4KW 8KVA/7.2KW 11KVA/10KW

Input

Input Voltage Range 100~276VAC

Frequency Range 45-55Hz / 54-66Hz

Input Wiring Single phase with ground

Current Distortion (THDi) <5% @ full load

Output

Output Power Factor 0.9

Nominal Output Voltage 208/220/230/240VAC

Voltage Regulation ± 1%

Frequency Range ( Battery Mode ) 50/60 ± 0.1 Hz

Current Crest Ratio 3:1

Voltage Distortion (THDv) <2%

Output Waveform Pure Sine Wave

Parallel Operation Up to 2 units

EfficiencyInverter Mode Up to 94% Up to 95%

ECO Mode Up to 98%

BatteryRated Battery Voltage 180VDC 240VDC

Backup Time (@ 50%/70% load) 13/10mins 11/8mins 20/15mins 13/9mins

Transfer time

Battery Mode ↔ Inverter Mode 0 ms

Inverter Mode ↔ Bypass Mode 0 ms

ECO Mode ↔ Battery Mode <10 ms

Display Multi-language LCD

Audible alarm Yes

Dimension

UPS (WxHxD) 440 x 130x 685 mm 440 x 130x 685 mm NA NA

Power module (WxHxD) NA NA 440 x 130x 680 mm 440 x 230x 680 mm

EBM (WxHxD) 440 x 130 x 645mm 440 x 130 x 645mm 440 x 130 x 700mm 440 x 130 x 700 mm

Net weight UPS 48kg 48 kg 84kg (Power module + EBM)

86kg (Power module + EBM)

Environment

Operating Temperature 0-40° C

Noise Level <45dB <48dB <50dB

Safety IEC/EN 62040-1, UL 1778

EMC IEC/EN 62040 -2, FCC Class A

Approval CE, CB report (TUV), UL

Interface

RS232/USB Yes

Communication card Integrated

Emergency Power Off Yes

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 13: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

KEY FEATURE

• True double-conversion design with high adaptability to harsh mains conditions

• Ideal to for high-end equipment which are sensitive to power quality

• Supports energy-saving ECO mode

• Wide input range (120-276VAC)

• Intelligent communication slot enables remote monitoring

• Precise output voltage regulation

• Rack/tower dual set-up with rotatable LCD panel

• Intelligent Charging Management* for batteries prolongs battery life

1/1.5K/2K/3KInnova RT series

Typical Application

Online UPS

Network equipment Home appliances

Ac mains

Office devices

Page 14: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model Innova RT 1K

Innova RT 1KS

Innova RT 1.5K

Innova RT 1.5KS

Innova RT 2K

Innova RT 2KS

Innova RT 3K

Innova RT 3KS

Capacity 1000VA/900W 1500VA/1350W 2000VA/1800W 3000VA/2700W

Input

Input Voltage Range 120~276VAC

Frequency Range 45~55Hz/54~66Hz

Input Wiring Single Phase with ground

Current Distortion (THDi) <5% @ full load

Output

Output Power Factor 0.9

Nominal Output Voltage 208/220/230/240VAC

Voltage Regulation ± 1%

Frequency Range ( Battery Mode ) 50/60 ± 0.2 Hz

Current Crest Ratio 3:1

Voltage Distortion (THDv) <2% @ Linear Load, <5% @ Non-Linear Load

Output Waveform Pure Sine Wave

Parallel Operation N/A

Efficiency

Inverter Mode 88% 89% 92%

Battery Mode 83% 84% 88%

ECO Mode 95%

Battery

Battery Type 12V/7Ah N/A 12V/7Ah N/A 12V/9Ah N/A 12V/9Ah N/A

Number of Internal Battery 3 N/A 4 N/A 4 N/A 6 N/A

Rated Battery Voltage 36VDC 48VDC 48VDC 72VDC

Backup Time (@ Full Load) > 5min N/A > 5min N/A > 5min N/A > 5min N/A

Recharge Time (to 90%) 3 hour N/A 3 hour N/A 3 hour N/A 3 hour N/A

Charging Current (max) 1.5A 6A 1.5A 6A 1.5A 6A 1.5A 6A

Transfer Time

Battery Mode ↔ Inverter Mode 0 ms

Inverter Mode ↔ Bypass Mode 4 ms

ECO Mode ↔ Battery Mode <10 ms

Display LCD

Audible Alarm Yes

Dimension WxHxD 438 x 86.5 x 435 mm 438 x 86.5 x 604 mm

Net Weight 16.2 kg 8.4 kg 19.7 kg 9.3 kg 19.7 kg 9.3kg 27.8 kg 13 kg

EnvironmentOperating Temperature 0-40° C

Noise Level <45dB @ 1 Meter <50dB @ 1 Meter

Interface

RS232/USB Yes

External Slot Yes

Emergency Power Off Yes

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 15: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

KEY FEATURE

• True double-conversion design with high adaptability to harsh mains conditions

• Ideal to for high-end equipment which are sensitive to power quality

• Supports energy-saving ECO mode

• Wide input range (120-276VAC)

• Intelligent communication slot enables remote monitoring

• Precise output voltage regulation

• Rack/tower dual set-up with rotatable LCD panel

• Intelligent Charging Management* for batteries prolongs battery life

6K/10K

Online UPS

Innova RT series

Ac mains/Generator

Health care TelecomNetworkequipment

Financial Work station

Typical Application

Page 16: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model INNOVA RT 6K Innova RT 6KS Innova RT 10K Innova RT 10KS

Capacity 6000VA/5400W 10000VA/9000W

Input

Input Voltage Range 120~276VAC

Frequency Range 45-55Hz / 54-66Hz

Input Wiring Single phase with ground

Current Distortion (THDi) <5% @ full load

Output

Output Power Factor 0.9

Nominal Output Voltage 208/220/230/240VAC

Voltage Regulation ± 1%

Frequency Range ( Battery Mode ) 50/60 ± 0.1 Hz

Current Crest Ratio 3:1

Voltage Distortion (THDv) <2% @ Linear Load, <5% @Non-Linear Load

Output Waveform Pure Sine Wave

Parallel Operation Up to 2 units

Efficiency

Inverter Mode 92% 93%

Battery Mode 89% 90%

ECO Mode 96% 97%

Battery

Battery Type 12V/5Ah N/A 12V/9Ah N/A

Number of Internal Battery 15 N/A 20 N/A

Rated Battery Voltage 180VDC 240VDC

Backup Time (@ Full Load) >2.5mins N/A > 3.5mins N/A

Recharge Time (to 90%) 3 hours N/A 3 hours N/A

Charging Current 1A 8A 1.7A 8A

Transfer Time

Battery Mode ↔ Inverter Mode 0 ms

Inverter Mode ↔ Bypass Mode 0 ms

ECO Mode ↔ Battery Mode <10 ms

Display LCD

Audible Alarm Yes

Dimension WxHxD 438 x 129 x 698 mm 438 x 129 x 640 mm 438 x 215.5 x 704 mm 438 x 215.5 x 640 mm

Net Weight 46kg 19 kg 82.5kg 26kg

EnvironmentOperating Temperature 0-40° C

Noise Level <55dB @ 1 Meter

Interface

RS232/USB Yes

External Slot Yes

Emergency Power Off Yes

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 17: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Line-interactive UPS

500/750/1000/1500Spring MT series

Typical Application

KEY FEATURE

• High performance supported by sinewave output and built-in voltage regulator

• Compact foot print fits easily into small spaces such as kiosks, cash machines and ticket machines

• HID-UPS-Battery-supported USB* interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS and Linux

• High conversion efficiency (>95%) results in energy saving

• LCD graphic display gives comprehensive information at a glance

• Easy battery replacement

Office devices NasHome appliances

Ac mains

Desktop PC

Page 18: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model Spring MT500

Spring MT 750

Spring MT 1000

Spring MT 1500

Capacity 500VA/350W 750VA/500W 1000VA/700W 1500VA/900W

Input

Input Voltage Range 176-288VAC

Frequency Range 45-55 Hz / 55-65 Hz

Input Wiring Single phase with ground

Output

Output Power Factor 0.7 0.6 0.7 0.6

Nominal Output Voltage 220/230/240VAC

Voltage Regulation (Line Mode) -10% ~ +6%

Voltage Regulation (Battery Mode) -10% ~ +6%

Frequency Range ( Battery Mode ) 50/60 Hz ±0.1 Hz

Output Waveform Pure sine wave

Parallel Operation N/A

Efficiency

Line Mode > 94%

AVR Mode > 90%

Battery Mode > 70%

Battery

Battery Type 12V/7Ah 12V/9Ah 12V/7Ah 12V/9Ah

Number of Internal Battery 1 1 2 2

Rated Battery Voltage 12VDC 24VDC

Backup Time (@ Typical PC load) 17 min 20 min 35 min 40 min

Recharge Time (to 90%) 3 hours

Transfer Time Battery Mode ↔ Line Mode <10ms

Display LCD

Audible Alarm Yes

Dimension WxHxD 150x209X240 mm 150x209x340 mm

Net Weight 6.4 kg 6.8 kg 10.8 kg 11.5 kg

EnvironmentOperating Temperature 0~40° C

Noise Level <40dBA @ 1 meter <45 dBA@1 meter

Interface USB Yes

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 19: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

650/850/1150/1550

Line-interactive UPS

Spring rack 1U premium series

Typical Application

KEY FEATURE

• Multi language LCD and CB safety certificate support global distribution with minimum SKU.

• Eaton ABM® battery management technology uses an innovative three-stage charging technique that extends battery life by up to 50%.

• Batteries can be hot-swapped without ever having to shutdown connected equipment.

• Tool-less battery replacement minimize service complexity.

• Unmatched energy density with up to 1.1kW in only 1U

• Efficiency up to 98%

• Recharge to 90% battery capacity within 3 hours

Network equipment Home appliances

Ac mains

Office devices

Page 20: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model 650VA 850VA 1150VA 1550VA

Capacity 650VA/420W 850VA/600W 1150VA/770W 1550VA/1100W

Input

Input Voltage Range 150~294VAC

Frequency Range 45-55Hz / 55-65 Hz

Input Wiring Single phase with ground

Output

Nominal Output Voltage 200/208/220/230/240VAC

Voltage Regulation (Line Mode) -10% ~ +6%

Output Waveform Pure sine wave

EfficiencyLine Mode 97% 98%

AVR Mode Boost mode: 92%, Buck mode: 95%

Battery

Battery Type 6V/9Ah 6V/7Ah 6V/9Ah 6V/9Ah

Number of Internal Battery 2 4 4 6

Rated Battery Voltage 12V 24V 24V 36V

Backup Time (@ 50% / 70% load) 9 / 6 min 12 / 7 min 12 / 7 min 13 / 8min

Recharge Time (to 90%) 3 hours

Transfer Time Battery Mode ↔ Line Mode 10ms maximum

Display Multi-language LCD

Audible Alarm Yes

Dimension WxHxD 438 x 43.2 x364 mm 438 x 43.2 x 509 mm 432 x 43.2 x 554 mm

Net Weight 8.6Kg 13.8Kg 14.6Kg 19.4Kg

Environment

Operating Temperature 0~35°C 0 ~ 40°C

Noise Level <45dB

Safety IEC/EN 62040-1, UL 1778

EMC IEC/EN 62040 -2

Approval CE, CB report (TUV)

InterfaceRS232/USB Yes

Communication card Optional

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 21: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

1.5K/2K/3K

Line-interactive UPS

Spring RT premium series

KEY FEATURE

• Multi language LCD and CB safety certificate support global distribution with minimum SKU

• Eaton ABM® battery management technology uses an innovative three-stage charging technique that extends battery life by up to 50%

• Tool-less battery replacement minimize service complexity

• Load segment control enables maximize battery runtime for critical devices

• Output power factor 0.9

• Efficiency up to 99%

• Recharge to 90% battery capacity within 3 hoursTypical Application

Network equipment Home appliances

Ac mains

Office devices

Page 22: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model 1.5K 2K 3K

Capacity 1.5KVA/1.35KW 2KVA/1.8KW 3KVA/2.7KW

Input

Input Voltage Range 150~294VAC

Frequency Range 45-55Hz / 55-65 Hz

Input Wiring Single phase with ground

Current Distortion (THDi) 10%

Output

Output Power Factor 0.9

Nominal Output Voltage 200/208/220/230/240VAC

Voltage Regulation (Line Mode) -10% ~ +6%

Output Waveform Pure sine wave

Efficiency

Line Mode 99%

AVR Mode Boost mode: 92%, Buck mode: 95%

Battery Mode >82% >80%

Battery

Battery Type 12V/7Ah 12V/9Ah 12V/9Ah

Number of Internal Battery 4 4 6

Rated Battery Voltage 48V 48V 72V

Backup Time (@ 50% / 70% load) 19 / 11 min 15 / 8 min 14 / 9 min

Recharge Time (to 90%) 3 hours

Transfer Time Battery Mode ↔ Line Mode 10ms maximum

Display Multi-language LCD

Audible Alarm Yes

Dimension WxHxD 441 x 86.2 x 552 mm 441 x 86.2 x 647 mm (2U)441 X 130.7 x 497 mm (3U)

Net Weight 27.6kg 28.5kg 38.08Kg (2U) / 37.33Kg (3U)

EnvironmentOperating Temperature 0~40°C

Noise Level <45dB <50dB

Safety IEC/EN 62040-1

EMC IEC/EN 62040-2

Approval CE, CB report, TÜV

InterfaceRS232/USB Yes

Communication card Optional

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 23: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

1K/1.5K

Line-interactive UPS

Spring RT series

KEY FEATURE

• High output power factor (0.9)

• Built-in voltage regulator stables unstable AC input power

• Intelligent communication slot enables remote monitoring

• HID-UPS-Battery-supported USB* interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS and Linux

• Rack/tower dual set-up with rotatable LCD panel

• Optional EBM (Extended Battery Module) available for battery expansion

Typical Application

Network equipment Home appliances

Ac mains

Office devices

Page 24: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model Spring RT 1K Spring RT 1KS Spring RT 1KE Spring RT 1.5K Spring RT 1.5KS

Capacity 1000VA/900W 1500VA/1350W

Input

Input Voltage Range 154~288VAC

Frequency Range 45-55Hz / 55-65 Hz

Input Wiring Single phase with ground

Current Distortion (THDi) 10%

Output

Output Power Factor 0.9

Nominal Output Voltage 220/230/240VAC

Voltage Regulation (Line Mode) -10% ~ +6%

Voltage Regulation (Battery Mode) ± 5 %

Frequency Range ( Battery Mode ) 50/60 Hz ± 0.1 Hz

Voltage Distortion (THDv) < 3% @ linear load, < 6% @ non-linear load < 10% @ linear load < 3% @ linear load, < 6% @ non-linear load

Output Waveform Pure sine wave

Parallel Operation N/A

Efficiency

Line Mode 97%

AVR Mode Boost mode: 92%, Buck mode: 95%

Battery Mode >82% >80% >82%

Battery

Battery Type 12V/7Ah N/A 12V/9Ah 12V/9Ah N/A

Number of Internal Battery 3 N/A 2 3 N/A

Rated Battery Voltage 36VDC 24VDC 36VDC

Backup Time (@ full load) 4.5 min N/A 3min 3 min N/A

Recharge Time (to 90%) 3 hours N/A 8 hours 4 hours N/A

Charging Current 1.5A 7A 1.1A 1.5A 7A

Transfer Time Battery Mode ↔ Line Mode 2-6 ms

Display LCD

Audible Alarm Yes

Dimension WxHxD 438 X 86.5 x 435 mm

Net Weight 16kg 10kg 13kg 17.9kg 10kg

EnvironmentOperating Temperature 0~40°C

Noise Level <45dB

Interface

RS232/USB Yes

External Slot Yes N/A Yes

Dry Contact Yes N/A Yes

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 25: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

2K/3KSpring RT series

KEY FEATURE

• High output power factor (0.9)

• Built-in voltage regulator stables unstable AC input power

• Intelligent communication slot enables remote monitoring

• HID-UPS-Battery-supported USB* interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS and Linux

• Rack/tower dual set-up with rotatable LCD panel

• Optional EBM (Extended Battery Module) available for battery expansion

Line-interactive UPS

Typical Application

Network equipment Home appliances

Ac mains

Office devices

Page 26: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model Spring RT 2K Spring RT 2KS Spring RT 2KE Spring RT 3K Spring RT 3KS

Capacity 2000VA/1800W 3000VA/2700W

Input

Input Voltage Range 154~288 VAC

Frequency Range 45-55Hz / 55-65 Hz

Input Wiring Single phase with ground

Current Distortion (THDi) 10%

Output

Output Power Factor 0.9

Nominal Output Voltage 220/230/240VAC

Voltage Regulation (Line Mode) -10% ~ +6%

Voltage Regulation (Battery Mode) ± 5 %

Frequency Range ( Battery Mode ) 50/60 Hz ± 0.1 Hz

Voltage Distortion (THDv) < 3% @ linear load, < 6% @ non-linear load

Output Waveform Pure sine wave

Parallel Operation N/A

Efficiency

Line Mode 97%

AVR Mode Boost mode: 92%, Buck mode: 95%

Battery Mode 80%

Battery

Battery Type 12V/7Ah N/A 12V/9Ah 12V/9Ah N/A

Number of Internal Battery 6 N/A 4 6 N/A

Rated Battery Voltage 72VDC 48VDC 72VDC

Backup Time (@ full load) 4.5 min N/A 3 min 3 min N/A

Recharge Time (to 90%) 3 hours N/A 4 hours 4 hours N/A

Charging Current 1.5A 7A 1.5A 1.5A 7A

Transfer Time Battery Mode ↔ Line Mode 2-6 ms

Display LCD

Audible Alarm Yes

Dimension WxHxD 438 X 86.5 x 604 mm 438 X 86.5 x 436 mm 438 X 86.5 x 604 mm

Net Weight 28kg 16kg 21kg 31kg 16kg

EnvironmentOperating Temperature 0~40°C

Noise Level <45dB

Interface

RS232/USB Yes

External Slot Yes

Dry Contact Yes

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 27: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

600Uni series

KEY FEATURE

• Designed to backup network device and charge mobile phone so as to stay connected to internet during power outage

• Optimized design leads to cost-saving and space-saving

• Built-in AVR with boost and buck circuit to deal with challenging power conditions

• Compact size which can be easily fit with PC-related equipment

• Top access of outlet makes power core connection easier

Line-interactive UPS

Typical Application

Network equipment Home appliances

Ac mains

Desktop PC

Page 28: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model UNI 600

Capacity 600VA/360W

Input

Input Voltage Range 150~290VAC

Frequency Range 47~53/57~63 Hz

Input Wiring Single phase with ground

Output

Output Power Factor 0.6

Nominal Output Voltage 230VAC

Voltage Regulation (Line Mode) N/A

Voltage Regulation (Battery Mode) ±10%

Frequency Range ( Battery Mode ) 50± 1 Hz

Output Waveform Modified sine wave

Parallel Operation N/A

Efficiency

Line Mode >95%

AVR Mode N/A

Battery Mode >60%

Battery

Battery Type 12V/4.5Ah

Number of Internal Battery 1

Rated Battery Voltage 12VDC

Backup Time (@ 120W load) 7.9 min

Recharge Time (to 90%) 6 hours

Charging Current N/A

Transfer Time Battery Mode ↔ Line Mode 4-6 ms

Display LED

Audible Alarm Yes

Dimension WxHxD 100 x 143x 200 mm

Net Weight 3.8kg

EnvironmentOperating Temperature 0~40°C

Noise Level <40dB

Interface

USB No

External Slot No

TVSS protection No

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 29: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

450/650/850/1200/2200

Line-interactive UPS

Aurora series+

Typical Application

Network equipment Home appliances

Ac mains

Desktop PC

• Cost effective backup solution with excellent performance

• Built-in voltage regulator for reliable power quality

• Super fast charger shortens the charging time to 2-4 hours

• DC cold start function

• AC Overloading protection

• Surge protection for phone / modem line (optional)

• CE compliant

KEY FEATURE

Page 30: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model Aurora 450

Aurora650

Aurora850

Aurora 1200

Aurora2200

Capacity 450VA/240W 650VA/360W 850VA/480W 1200VA/600W 2200VA/1100W

Input

Input Voltage Range 162-290 VAC

Frequency Range 45~55Hz/55~65Hz

Input Wiring Single phase with ground

Output

Output Power Factor 0.55 0.5

Nominal Output Voltage 110/120/220/230/240VAC

Voltage Regulation (Line Mode) ±15%

Voltage Regulation (Battery Mode) ±10%

Frequency Range ( Battery Mode ) 50/60Hz ± 1Hz

Output Waveform Modified sine wave

Parallel Operation N/A

Efficiency

Line Mode 95%

AVR Mode 88%

Battery Mode 60%

Battery

Battery Type 12V/4.5Ah 12V/7Ah 12V/9Ah 12V/7Ah 12V/9Ah

Number of Internal Battery 1 1 1 2 2

Rated Battery Voltage 12VDC 12VDC 12VDC 24VDC 24VDC

Backup Time (@ Typical PC load) 8 min 16 min 20 min 40 min 50 min

Recharge Time (to 90%) 2-4 hours

Charging Current 1A

Transfer Time Battery Mode ↔ Line Mode 2-6 ms 4-8 ms

Display LED

Audible Alarm YES

Dimension WxHxD 100 x 143 x 300 mm 139 X 195 x 364 mm

Net Weight 3.5kg 4.5kg 5.0kg 8.8kg 10.3kg

EnvironmentOperating Temperature 0~40°C

Noise Level <40dB <45dB

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 31: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

650/850/1200/2200

Typical Application

Line-interactive UPS

Aurora vista series

Network equipment Home appliances

Ac mains

Desktop PC

Page 32: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model Aurora vista650

Aurora vista 850

Aurora vista 1200

Aurora vista 2200

Capacity 650VA/360W 850VA/480W 1200VA/600W 2200VA/1200W

Input

Input Voltage Range 162~290VAC

Frequency Range 45~55/55~65 Hz

Input Wiring Single phase with ground

Output

Output Power Factor 0.55 0.56 0.5 0.55

Nominal Output Voltage 220/230/240 VAC

Voltage Regulation (Line Mode) ±15%

Voltage Regulation (Battery Mode) ±10%

Frequency Range ( Battery Mode ) 50/60Hz ± 1 Hz

Output Waveform Modified sine wave

Parallel Operation N/A

Efficiency

Line Mode 95%

AVR Mode 88%

Battery Mode 60%

Battery

Battery Type 12V/7Ah 12V/9Ah 12V/ 7Ah 12V/9Ah

Number of Internal Battery 1 1 2 2

Rated Battery Voltage 12VDC 12VDC 24VDC 24VDC

Backup Time (@ Typical PC load) 16 min 20 min 30 min 50 min

Recharge Time (to 90%) 2-4 hours

Charging Current 1A

Transfer Time Battery Mode ↔ Line Mode 2-6 ms 4-8 ms

Display LCD

Audible Alarm Yes

Dimension WxHxD 100 x 143x 290 mm 139 x 195 x 364 mm

Net Weight 4.4 kg 5.2 kg 8.9 kg 10.4 kg

EnvironmentOperating Temperature 0~40°C

Noise Level <40dB <45dB

Interface

USB Yes

External Slot No

TVSS protection RJ11 Jack RJ45 Jack

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 33: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

400/600/800APFC office series

KEY FEATURE

Standby UPS

• Supports loads with APFC (Active Power Factor Correction)* switching power supply with patented design

• Quick installation and easy to operate

• Easy battery replacement

• Surge protection for all receptacles

• Jack for phone/model lines with surge protection

• Easy-to-understand LED indicator

• Protection against faults and overloadingTypical Application

Router/ModemHome appliances

Ac mains

Desktop PC

Page 34: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model APFC office 400 APFC office 600 APFC office 800

Capacity 400VA/200W 600VA/300W 800VA/420W

Input

Input Voltage Range 170~270VAC

Frequency Range 45~55/55~65 Hz

Input Wiring Single phase with ground

Output

Output Power Factor 0.5 0.525

Nominal Output Voltage 230VAC

Voltage Regulation (Battery Mode) ±10%

Frequency Range ( Battery Mode ) 50Hz/60Hz ±1Hz

Output Waveform Modified sine wave

EfficiencyLine Mode >95%

Battery Mode >70%

Battery

Battery Type 12V/4.5Ah 12V/5Ah 12V/7Ah

Number of Internal Battery 1

Rated Battery Voltage 12V

Backup Time (@ typical PC load) 9 min 17 min 20 min

Recharge Time (to 90%) < 10 hours

Charging Current 0.5A 1A

Transfer Time Battery Mode ↔ Line Mode 2-8 ms

Display LED

Audible Alarm YES

Dimension WxHxD 320 x 125 x 86 mm 335 x 170 x 92.5 mm

Net Weight 3.7 kg 5 kg

EnvironmentOperating Temperature 0- 40°C

Noise Level <40dB

Interface TVSS Protection Yes

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 35: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Ac mains/Generator

1K/2KMax series

Typical Application

AC inverter

KEY FEATURE

• AC Inverter with built-in SCC (Solar Charger Controller)

• Fast batter Charging with solar power regardless the presence of AC mains

• Largely extended backup time whenever solar power is present

• Wide AC input voltage range which supports both AC mains and generator

• Up to 98% efficiency under line mode which results in energy saving

• Strong charging capability which gives flexibility on battery configuration

• Built-in MPPT to maximize solar energy harvest

Solar panel

Battery Home appliances

Page 36: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model Max 1K Max 2K

Capacity 1000VA/720W 2000VA/1300W

Ac input

Nominal Input Voltage 230VAC

Input Voltage Range (normal range)1 170-280VAC

Input Voltage Range (wide range) 1 90-280VAC

Ac output

Nominal Output Voltage 230VAC

Output Voltage Waveform Modified sine wave

Output Voltage Regulation (Bat. Mode) -18 ~ +10%

Output Frequency 50Hz / 60Hz ± 1Hz

Protection 10A fuse

Ac charger(Chargedby AC mains)

Nominal Battery Voltage 12VDC 24VDC

Charger Current 15/20A (configurable) 10A

Solar charger(Chargedby solar power)

Max Solar Output Power2 450W 900W

Optimal Input Voltage Range 15-18VDC 30-36VDC

Max Solar Input Voltage 55VDC

Charging Current 40A max

Efficiency

AC to AC >95%

DC to AC >80%

Transfer time Line Mode → Battery Mode 15ms (narrow range setting)40ms (wide range setting)

Display 1 x LCD, 3 x LED indicators

Dimension WxHxD 245 X 97.5 X 272 mm

Net weight 2.22kg 2.25kg

Environment

Operating Temperature 0-50℃

Noise Level <50dB

Note: 1. Normal input range and wide input range can be configured via LCD.2. The installed capacity of solar panel shall be no larger than this value.

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 37: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

AC inverter

3K/5KMax series

KEY FEATURE

• AC Inverter with built-in SCC (Solar Charger Controller)

• Fast batter Charging with solar power regardless the presence of AC mains

• Largely extended backup time whenever solar power is present

• Wide AC input voltage range which supports both AC mains and generator

• Up to 98% efficiency under line mode which results in energy saving

• Strong charging capability which gives flexibility on battery configuration

• Built-in MPPT to maximize solar energy harvest

Ac mains/Generator

Typical Application

Solar panel

Battery Home appliances

Page 38: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model Max 3K Max 5K

Capacity 3000VA/2400W 5000VA/4200W

AC input

Nominal Input Voltage 230VAC

Input Voltage Range (normal range)1 175-280VAC

Input Voltage Range (wide range) 1 125-280VAC

AC output

Nominal Output Voltage 230VAC

Output Voltage Waveform Pure sine wave

Output Voltage Regulation (Bat. Mode) ±10%

Output Frequency 50Hz / 60Hz ± 1Hz

Protection 30A breaker 40A breaker

Max Motor-based Loading 1.5HP 2.5HP

AC charger(charged by AC mains)

Nominal Battery Voltage 24VDC 48VDC

Charger Current 20/10A (configurable) 25A

Solar Charger(charged by solar power)

Max Solar Output Power2 800W 2400W

Optimal Input Voltage Range 30-75VDC 60-150VDC

Max Solar Input Voltage 75VDC 150VDC

Charging Current 40A 60A

EfficiencyAC to AC >98%

DC to AC >90%

Transfer time Line Mode → Battery Mode 10ms (narrow range setting)20ms (wide range setting)

Display 1 x LCD

Dimension WxHxD 268.4x85.2x318 mm 350.4x119.1x428.5 mm

Net weight 5.7kg 10.4kg

EnvironmentOperating Temperature 0-50℃

Noise Level <60dB

Note: 1. Normal input range and wide input range can be configured via LCD.2. The installed capacity of solar panel shall be no larger than this value.

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 39: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

KEY FEATURE

• 3-Phase in/3-phase out , double-conversion online UPS

• Up to 98% efficiency under High Efficiency mode results in significant energy saving

• Intelligent management of battery charging prolongs battery lifetime

• Pre-wired for easy installation

• Hot Parallel Connection technology

• Allows dedication of more floor space to revenue producing equipment

15K/20K/30K/40K/60K/80K

3 Phase UPS

APUS series

Typical Application

Precision equipment

TelecomData center Network equipment

Ac mains/Generator

Page 40: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model APUS 15K

APUS15KS

APUS20K

APUS 20KS

APUS 30K

APUS 30KS

APUS 40K

APUS 40KS

APUS 60KS

APUS 80KS

Capacity 15KVA/ 13.5KW 20KVA/18KW 30KVA/27KW 40KVA/36KW 60KVA/54KW

80KVA/72KW

Input

Nominal Voltage 380/400/415 VAC(L-L) (selectable)

Input Voltage Range 201-478VAC(L-L)

Frequency Range 42~72Hz

Input Wiring 3 phases + Neutral + PE (TN, TN-S, TN-C, TN-C-S, TT)

Current Distortion (THDi) <5%

Output

Output Power Factor 0.9

Nominal Output Voltage 380/400/415 VAC(L-L) (selectable)

Voltage Regulation ±1% @ balanced static load

Frequency Range ( Battery Mode ) 50/60 Hz ± 0.005Hz

Current Crest Ratio 3:1

Voltage Distortion (THDv) 2% @ linear load, <5% @ non-linear load

Output Waveform Pure sine wave

Parallel Operation Up to 4 units

EfficiencyInverter Mode 94%

ECO Mode 98%

Battery

No. of Internal Battery 64x12V/9Ah N/A 64x12V

/9Ah N/A 96x12V/9Ah N/A 128x12V

/9Ah N/A

Backup Time

Recharge Time (to 90%) 10 hours N/A 10 hours N/A 10 hours N/A 10 hours N/A

Charging Current 5.3A 8A 10.6A 16A 24A

Transfer Time

Battery ↔ Inverter Mode 0ms

Inverter↔ Bypass Mode 0ms

ECO ↔ Inverter Mode 4ms

Display Graphical LCD, 4x LEDs

Audible Alarm Yes

Dimension WxHxD (mm) 500x960x706 500x1230x706 500x1500x706 600x1876x796

Net Weight 240kg 72kg 240kg 72kg 340kg 88kg 455kg 120kg 202kg 245kg

EnvironmentOperating Temperature 0-40°C

Noise Level ≤55dB @ 75% Load ≤62dB @ 75% Load ≤65dB @ 75% Load

Interface

RS232/USB Yes

External Slot Yes

Emergency Power Off Yes

Building Alarm Yes

Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan TEL: +886-2-2794-6363 Fax: +886-2-6606-8711 Website: www.centralion.com

Copyright © 2016 Centralion Industrial Inc.All Rights Reserved.

Page 41: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

15K-150K

Modular UPS

Gripower pro series

• Supports up to 10x15KVA UPS modules up to 150KVA output capacity

• Hot-swappable UPS module with wireless design

• N+X parallel redundant configuration which leaves no SPOF (Single Point of Failure)

• 7” colorful touch-screen LCD

• Easy installation and load expansion resulted from modular design

• 3 multi-function intelligent ports

• Dynamic load-sharing design

• Optimized performance with >93% efficiency

• Supports AC generator as AC input

• Configurable battery quantity from 32 to 42 pieces per set

KEY FEATURE

Typical Application

Precision equipment

TelecomData center Network equipment

Ac mains/Generator

Page 42: Innova G2 T series - CENTRALION · Innova G2 T series 1K/2K/3K/1KL/2KL/3KL Online UPS Typical Application KEY FEATURE • True double-conversion design with high adaptability to

Specification

Model Gripower Pro

Capacity Each Module 15KVA/13.5kW

Max. Module in Parallel 10

Input

Input Voltage Range 304-520 VAC

Frequency Range 40-70 Hz

Input Wiring 3-phase/4-wire + PE

Current Distortion (THDi) <5% @ 100% RCD load

Output

Output Power Factor 0.9

Nominal Output Voltage 353/380/400/415 VAC

Voltage Regulation ±1%

Frequency Range ( Battery & Converter Mode ) 50/60Hz ±0.05Hz

Current Crest Ratio 2.5:1

Voltage Distortion (THDv) <2% @ linear load, <4% @ non-linear load

Output Waveform Pure sine wave

Cabinet Parallel Operation N/A

EfficiencyInverter Mode 93%

Battery Mode 93%

Battery

Battery Connection External

Number of Battery 32~40 pcs

Rated Battery Voltage ± Kx12 VDC (K = 16 to 20)

Charging Current per Module 3.5A

Transfer TimeBattery Mode ↔ Inverter Mode 0 ms

Inverter Mode ↔ Bypass Mode 0 ms

Display 7” touch panel LCD

Audible Alarm Yes

Cabinet Dimension WxHxD 600x2030x1000 mm

Net Weight 90KVA: 230kg / 120KVA: 265kg / 150KVA: 275kg

EnvironmentOperating Temperature 0 – 40 ℃

Noise Level <62dBA

Interface

RS232/USB Yes

External Slot Supports SNMP/AS400/NMC/CMC card

Emergency Power Off Yes