Improving Fired Heaters Reliability using Inclined
Firing Technology
Furnace Improvements
1
-
Furnace
Improvements
ServicesOperating and Reliability Issues
High tube metal temperatures
Localized flame impingement
Fired heaters have burners that are fired vertically upright, sideways or
downwards
FIS patented technology reorients the burners at a slight angle away
from the tubes
Hottest part of the flames and flue gases are moved away from the
tubes
www.heatflux.com 2
-
Furnace
Improvements
ServicesBenefits of Inclined Firing System
Significant reduction in tube metal temperatures
Low coking rates
Higher tube life and run lengths
Increased capacity possible in most heaters
Uniform firing achieved across the tubes
www.heatflux.com 3
-
Furnace
Improvements
Services
9/9/2014 www.heatflux.com 4
4'
BCD
12'-9"
TCD
12'-9"
INLET
OUTLET
4'
4'-4
2'-7"
4'
BCD
6'
5'
2'-7"
12'-9"
TCD
12'-9"
INLET
OUTLET
4'
Burners areinclined at5-10 deg.
Inclined Firing
System
-
INTERHEATER -2 INTERHEATER -1 CHARGE HEATER
35'-6" 35'-6"
5' 5'
6'
5' 5'
4'-6"
5' 5'
4'-6"
5-10deg.
-
Furnace
Improvements
ServicesInclined Firing System
www.heatflux.com 6
Height in
Elevation
BCD
0-0 8-0
5-0 7-1.5
10-0 6-3
15-0 5-4.5
20-0 4-6
25-0 3-7.5
8 burner systemTCD of 20-8
2'-7"
21'-9 1/2" I/S INS.
20'-8"TCD
8'-0"B.C.D.
7'-1 1/2"
B.C.D.
6'-3"
5'-4 1/2"
4'-6"
3'-7 1/2"
57
'-1
0" W
EL
D T
O W
EL
D L
EN
GT
H
61
'-4
1/2
"
45
'-8
5/8
"
5'-
0" 1
0'-
0" 15
'-0
" 20
'-0
" 25
'-0
"
10'-5"
I/S INS.
-
Furnace
Improvements
ServicesCase Studies
Case studies to be presented include:
Hot Oil Heater
Reformer Heater
Charge Heater, Vertical Cylindrical
Coker Heater
Crude Heater, Cabin Type
Crude Heater-Vertical Cylindrical
CFD Modeling carried out to demonstrate the benefits of Inclined
Firing System
www.heatflux.com 7
-
Furnace
Improvements
ServicesCFD Modeling
Start
CAD Geometry
CAD Geometry &
Meshing
Boundary
Conditions
Solver
Converged
Solution
Post Processor
Analysis
End
Diverge
Optimization
CFD
Computational Fluid Dynamics
Uses numerical methods and algorithms to study
fluid flow
Flow patterns in fired heaters, burners, fireboxes
3D models of fired equipment are created
www.heatflux.com 8
-
Furnace
Improvements
Services
Hot oil heater being built with 6 inclined burners ,commissioned in July 2014.
www.heatflux.com 9
-
Furnace
Improvements
Services
Hot Oil Heater
www.heatflux.com
-
Furnace
Improvements
ServicesFlue Gas Velocity Contours
Y-Plane
[ft/s]
-
Furnace
Improvements
ServicesFlue Gas Vector Plot
Long recirculation is observed.
Y-Plane
[ft/s]
-
Furnace
Improvements
ServicesFlame Contours (CO >2000 ppm)Colored by Temperature (o F)
[F]
Flame shapes are separate from each other.
[F]
-
Furnace
Improvements
ServicesFlame Contours (CO >2000 ppm)Colored by height (ft)
[ft]
[ft]
-
Furnace
Improvements
Services
Tube Metal Temperature Contours Wall Tubes
Tube Metal Temperatures Flue Gas Temperatures near Tubes
[F] [F]
-
Furnace
Improvements
ServicesWall Tubes Heat Flux Contours
Average Heat Flux on the Tubes:
10,482 Btu/hrft2
[Btu/hrft2]
-
Furnace
Improvements
Services
20'-0 7/8" (SHELL WIDTH)
24.0000
8 0.7500
113.0000 113.0000
4.0000 4.0000
24.0000
8 0.7500
EXISTING
4'-0"
2'-8 1/2"2'-8 1/2"
7.0000
5'-5" 5'-5"
20'-0 7/8" (SHELL WIDTH)
24.0000
8 0.7500
113.0000 113.0000
4.0000 4.0000
24.0000
8 0.7500
PROPOSED
4'-0"2'-8 1/2"
2'-8 1/2"
7.0000
5'-5" 5'-5"
3.5o
3.5o
7.0000
C B
UR
NE
RL C B
UR
NE
RL C
BU
RN
ER
L
PROPOSED INCLINED BURNER
EXISTING PROPOSED20'-0 7/8" (SHELL WIDTH)
24.0000
8 0.7500
113.0000 113.0000
4.0000 4.0000
24.0000
8 0.7500
EXISTING
4'-0"
2'-8 1/2"2'-8 1/2"
7.0000
5'-5" 5'-5"
20'-0 7/8" (SHELL WIDTH)
24.0000
8 0.7500
113.0000 113.0000
4.0000 4.0000
24.0000
8 0.7500
PROPOSED
4'-0"2'-8 1/2"
2'-8 1/2"
7.0000
5'-5" 5'-5"
3.5o
3.5o
7.0000
C B
UR
NE
RL C B
UR
NE
RL C
BU
RN
ER
L
PROPOSED INCLINED BURNER
Down Fired Steam Reformer
-
Furnace
Improvements
ServicesVelocity Vectors on Center Plane
In the proposed case, velocity vectors clearly show improvement in the flue gas flow
pattern with no direct contact of high velocity vectors on radiant tubes.
Base Case Proposed Case
[ft/s]
-
Furnace
Improvements
ServicesTemperature Contours on Center Plane
High flue gas temperature
going towards the tubes.
High flue gas temperature
going away from the tubes.
Base Case Proposed Case
In the proposed case, temperature contours clearly show the reduction in the flue gas
temperature around the radiant tubes.
[F]
-
Furnace
Improvements
Services
Charge Heater with 6 Burners
-
Furnace
Improvements
ServicesFlue Gas Temperature Contours
Central Plane
[F]
Temperature
near the
tube is high.
Flame angled
towards the center of
the furnace / away
from tubes.
Existing Case Proposed Modification
-
Furnace
Improvements
ServicesFlue Gas Temperature Contours
Plane
Location
Existing Case Proposed Modification
Temperature
near the tube
is high.
[F]
-
Furnace
Improvements
ServicesFluid Path Lines: from Fuel Inlet
Existing Case Proposed Modification
Outer
recirculation
pattern
[ft/s]
-
Furnace
Improvements
ServicesFlame Contours (CO >2000ppm)
[F]
Existing Case Proposed Modification
Colored by Temperature
[F]
-
Furnace
Improvements
ServicesFlame Contours (CO >2000ppm)
[ft]
Flame height is14 ft. Flame height is reduce to 9 ft.
Existing Case Proposed Modification
Colored by Height
[ft]
-
Furnace
Improvements
ServicesFlame Contours (5% O2)
[ft] Existing Case Proposed Modification
Flame
height
is16 ft.
Flame height is
reduce to 9.8 ft.
Colored by Height
[ft]
-
Furnace
Improvements
ServicesFlame Contours (3% O2)
[ft]
Flame height is 15.2 ft
at 3% O2.
Colored by Height
[ft]
-
Furnace
Improvements
ServicesTube Metal Temperatures
[F]
Existing Case Proposed Modification
Hot spots due
to flame
impingement.
TMTs more
uniform.
-
Furnace
Improvements
ServicesTube Heat Flux
High heat flux
distribution at
bottom of the
tubes
Existing Case Proposed Modification
[Btu/hrft2][Btu/hrft2]
-
Furnace
Improvements
ServicesCoker Heater
High tube metal temperature issues
Fuel gas fired low NOx burners
www.heatflux.com 30
-
Furnace
Improvements
ServicesCoker Heater Geometry
www.heatflux.com 31
ProposedExisting
Burners are
inclined by
7.5 towards the walls.
-
Furnace
Improvements
ServicesVelocity Vectors
www.heatflux.com 32
Expanded View[ft/s]
Plane at primary tip
-
Furnace
Improvements
ServicesVelocity Vectors by Temperature
www.heatflux.com 33
[F]
Plane at primary tip
-
Furnace
Improvements
ServicesTube Metal Temperature Contours
www.heatflux.com 34
[F]
-
Furnace
Improvements
ServicesRefractory Temperature Contours
www.heatflux.com 35[F]
-
Furnace
Improvements
ServicesFlame Shapes (Iso-Surface of
CO 2000 ppm)
36Colored by Temperature [F]
B-4B-1 B-2 B-3
-
Furnace
Improvements
ServicesFlow Profiles - Vertical Up Firingvs Inclined Firing
www.heatflux.com 37
Inclined Firing Vertical Up Firing
[ft/s]
-
Furnace
Improvements
Services
Flue Gas Temperature Profiles Vertical Up Firing vs Inclined Firing
www.heatflux.com 38
Inclined Firing Vertical Up Firing[F]
-
Furnace
Improvements
ServicesFlame Profiles - Vertical Up Firing
vs Inclined Firing
www.heatflux.com 39
Inclined Firing Vertical Up Firing
-
Furnace
Improvements
ServicesCrude Heater Horizontal Cabin
Cabin heater suffering from high tube metal
temperatures at arch
Originally 6 large burners-30 MMBtu/hr
each
Proposed 36 burners-5 MMBtu/hr each with
inclined firing mode
-
Furnace
Improvements
ServicesFlames Colored by Height
CO 2000 PPM
Base Case Proposed Design[ft]
-
Furnace
Improvements
ServicesVelocity Vectors - Z-1 Section
Base Case Proposed Design
Z-1Z-1
Z-2 Z-2
[ft/s]
-
Furnace
Improvements
ServicesTemperature Contours at Z Sections
Base Case Proposed Design[F]
-
Furnace
Improvements
ServicesRadiant Tube Temperature
Contours
Base Case Proposed Design
[F]
-
Furnace
Improvements
ServicesCrude Heater- Vertical Cylindrical
Client facing flame impingement and high tube
metal temperatures in radiant
section
FIS recommended inclined burner firing system to eliminate
flame impingement
Carried out CFD modeling of the burners and radiant section
to demonstrate the benefit of the
inclined burner firing system
www.heatflux.com 45
-
Furnace
Improvements
ServicesExisting Burner Arrangement
EXISTING FLOOR & PLENUM ARRANGEMENT
www.heatflux.com 46
-
Furnace
Improvements
ServicesInclined Firing System Burner Arrangement
www.heatflux.com 47
-
Furnace
Improvements
Services
Crude HeaterFloor Design
www.heatflux.com
-
Furnace
Improvements
Services
Crude HeaterPlenum Chambers
www.heatflux.com
-
Furnace
Improvements
ServicesVelocity Vectors
Base Case vs Inclined Firing System
www.heatflux.com 50
0 ft
Height in
Feet
19 ft
36 ft
50 ft
[ft/sec]
Existing Case
with Vertically Fired
Burners
Proposed Case
with Inclined Firing
System
-
Furnace
Improvements
ServicesTemperature ContoursBase vs Inclined Firing System
Base Case Inclined Firing System
www.heatflux.com 51
[F]
-
Furnace
Improvements
ServicesTemperature Contours at 10ftBase Case vs Inclined Firing System
Base Case Inclined Firing System
At 10 ft At 10 ft
www.heatflux.com 52
[F]
-
Furnace
Improvements
ServicesTemperature Contours at 15 ft -
Base Case vs Inclined Firing System
Base Case Inclined Firing System
1
At 15 ft At 15 ft
www.heatflux.com 53
[F]
-
Furnace
Improvements
ServicesCO Mass Fraction Contours at 10 ftBase Case vs Inclined Firing System
At 10 ft
Inclined Firing System
1
Base Case
At 10 ft
www.heatflux.com 54
[ppm]
-
Furnace
Improvements
ServicesCO Mass Fraction Contours at 15 ft
Base Case vs Inclined Firing System
At 15 Ft
Inclined Firing System
1
Base Case
At 15 Ft.
www.heatflux.com 55
[ppm]
-
Furnace
Improvements
Services
Iso Surface of CO MF 2000 PPM Colored by Temperatures
Base Case vs Inclined Firing System
Base Case Inclined Firing System
Top Viewwww.heatflux.com 56
[F] [F]
-
Furnace
Improvements
Services
Iso Surface of CO Mass Fraction 2000 ppm Colored by Flame Height
Base Case Inclined Firing
System
www.heatflux.com 57
[ft]
-
Furnace
Improvements
ServicesRadiant Wall Temperatures
Base Design Proposed Design
For h =100 Btu/ft2h and T= 800 F
www.heatflux.com 58
[F]
-
Furnace
Improvements
ServicesSummary
Client reported almost 250 F reduction in tube metal temperatures after the
revamp.
Inclined Firing is proven in solving high tube metal temperatures problems
CFD modeling demonstrated the ability of IFS to improve performance
FIS is ready to evaluate your heater to determine whether it is a suitable
candidate for Inclined Firing at no cost. www.heatflux.com 59
-
Furnace
Improvements
ServicesDHT Heater
Installation of 4 burners in inclined firing pattern
www.heatflux.com 60
-
Furnace
Improvements
Services
DHT HeaterFloor Layout
www.heatflux.com
-
Furnace
Improvements
ServicesSEU Units
www.heatflux.com 62
F-4202 F-4201
1650 2350
(TYP.)
3
(TYP.)
5.5
C B
UR
NE
R
C B
UR
NE
R
3200 (P.C.D.) 3962 (P.C.D.)
762 1372
B.C.D. B.C.D.
FLOOR PLT. FLOOR PLT.
L
L
C B
UR
NE
R
C B
UR
NE
RL
L
-
Furnace
Improvements
ServicesVertical Cylindrical Heaters
Two vertical cylindrical heaters working for almost 3 years with Inclined Firing System
Reduced fouling and hot spots
Provided 10% extra capacity
with Inclined Firing Technology
-