    Improving Fired Heaters Reliability using Inclined

    Firing Technology

    Furnace Improvements

    1

  • Furnace

    Improvements

    ServicesOperating and Reliability Issues

    High tube metal temperatures

    Localized flame impingement

    Fired heaters have burners that are fired vertically upright, sideways or

    downwards

    FIS patented technology reorients the burners at a slight angle away

    from the tubes

    Hottest part of the flames and flue gases are moved away from the

    tubes

    www.heatflux.com 2

  • Furnace

    Improvements

    ServicesBenefits of Inclined Firing System

    Significant reduction in tube metal temperatures

    Low coking rates

    Higher tube life and run lengths

    Increased capacity possible in most heaters

    Uniform firing achieved across the tubes

    www.heatflux.com 3

  • Furnace

    Improvements

    Services

    9/9/2014 www.heatflux.com 4

    4'

    BCD

    12'-9"

    TCD

    12'-9"

    INLET

    OUTLET

    4'

    4'-4

    2'-7"

    4'

    BCD

    6'

    5'

    2'-7"

    12'-9"

    TCD

    12'-9"

    INLET

    OUTLET

    4'

    Burners areinclined at5-10 deg.

    Inclined Firing

    System

  • INTERHEATER -2 INTERHEATER -1 CHARGE HEATER

    35'-6" 35'-6"

    5' 5'

    6'

    5' 5'

    4'-6"

    5' 5'

    4'-6"

    5-10deg.

  • Furnace

    Improvements

    ServicesInclined Firing System

    www.heatflux.com 6

    Height in

    Elevation

    BCD

    0-0 8-0

    5-0 7-1.5

    10-0 6-3

    15-0 5-4.5

    20-0 4-6

    25-0 3-7.5

    8 burner systemTCD of 20-8

    2'-7"

    21'-9 1/2" I/S INS.

    20'-8"TCD

    8'-0"B.C.D.

    7'-1 1/2"

    B.C.D.

    6'-3"

    5'-4 1/2"

    4'-6"

    3'-7 1/2"

    57

    '-1

    0" W

    EL

    D T

    O W

    EL

    D L

    EN

    GT

    H

    61

    '-4

    1/2

    "

    45

    '-8

    5/8

    "

    5'-

    0" 1

    0'-

    0" 15

    '-0

    " 20

    '-0

    " 25

    '-0

    "

    10'-5"

    I/S INS.

  • Furnace

    Improvements

    ServicesCase Studies

    Case studies to be presented include:

    Hot Oil Heater

    Reformer Heater

    Charge Heater, Vertical Cylindrical

    Coker Heater

    Crude Heater, Cabin Type

    Crude Heater-Vertical Cylindrical

    CFD Modeling carried out to demonstrate the benefits of Inclined

    Firing System

    www.heatflux.com 7

  • Furnace

    Improvements

    ServicesCFD Modeling

    Start

    CAD Geometry

    CAD Geometry &

    Meshing

    Boundary

    Conditions

    Solver

    Converged

    Solution

    Post Processor

    Analysis

    End

    Diverge

    Optimization

    CFD

    Computational Fluid Dynamics

    Uses numerical methods and algorithms to study

    fluid flow

    Flow patterns in fired heaters, burners, fireboxes

    3D models of fired equipment are created

    www.heatflux.com 8

  • Furnace

    Improvements

    Services

    Hot oil heater being built with 6 inclined burners ,commissioned in July 2014.

    www.heatflux.com 9

  • Furnace

    Improvements

    Services

    Hot Oil Heater

    www.heatflux.com

  • Furnace

    Improvements

    ServicesFlue Gas Velocity Contours

    Y-Plane

    [ft/s]

  • Furnace

    Improvements

    ServicesFlue Gas Vector Plot

    Long recirculation is observed.

    Y-Plane

    [ft/s]

  • Furnace

    Improvements

    ServicesFlame Contours (CO >2000 ppm)Colored by Temperature (o F)

    [F]

    Flame shapes are separate from each other.

    [F]

  • Furnace

    Improvements

    ServicesFlame Contours (CO >2000 ppm)Colored by height (ft)

    [ft]

    [ft]

  • Furnace

    Improvements

    Services

    Tube Metal Temperature Contours Wall Tubes

    Tube Metal Temperatures Flue Gas Temperatures near Tubes

    [F] [F]

  • Furnace

    Improvements

    ServicesWall Tubes Heat Flux Contours

    Average Heat Flux on the Tubes:

    10,482 Btu/hrft2

    [Btu/hrft2]

  • Furnace

    Improvements

    Services

    20'-0 7/8" (SHELL WIDTH)

    24.0000

    8 0.7500

    113.0000 113.0000

    4.0000 4.0000

    24.0000

    8 0.7500

    EXISTING

    4'-0"

    2'-8 1/2"2'-8 1/2"

    7.0000

    5'-5" 5'-5"

    20'-0 7/8" (SHELL WIDTH)

    24.0000

    8 0.7500

    113.0000 113.0000

    4.0000 4.0000

    24.0000

    8 0.7500

    PROPOSED

    4'-0"2'-8 1/2"

    2'-8 1/2"

    7.0000

    5'-5" 5'-5"

    3.5o

    3.5o

    7.0000

    C B

    UR

    NE

    RL C B

    UR

    NE

    RL C

    BU

    RN

    ER

    L

    PROPOSED INCLINED BURNER

    EXISTING PROPOSED20'-0 7/8" (SHELL WIDTH)

    24.0000

    8 0.7500

    113.0000 113.0000

    4.0000 4.0000

    24.0000

    8 0.7500

    EXISTING

    4'-0"

    2'-8 1/2"2'-8 1/2"

    7.0000

    5'-5" 5'-5"

    20'-0 7/8" (SHELL WIDTH)

    24.0000

    8 0.7500

    113.0000 113.0000

    4.0000 4.0000

    24.0000

    8 0.7500

    PROPOSED

    4'-0"2'-8 1/2"

    2'-8 1/2"

    7.0000

    5'-5" 5'-5"

    3.5o

    3.5o

    7.0000

    C B

    UR

    NE

    RL C B

    UR

    NE

    RL C

    BU

    RN

    ER

    L

    PROPOSED INCLINED BURNER

    Down Fired Steam Reformer

  • Furnace

    Improvements

    ServicesVelocity Vectors on Center Plane

    In the proposed case, velocity vectors clearly show improvement in the flue gas flow

    pattern with no direct contact of high velocity vectors on radiant tubes.

    Base Case Proposed Case

    [ft/s]

  • Furnace

    Improvements

    ServicesTemperature Contours on Center Plane

    High flue gas temperature

    going towards the tubes.

    High flue gas temperature

    going away from the tubes.

    Base Case Proposed Case

    In the proposed case, temperature contours clearly show the reduction in the flue gas

    temperature around the radiant tubes.

    [F]

  • Furnace

    Improvements

    Services

    Charge Heater with 6 Burners

  • Furnace

    Improvements

    ServicesFlue Gas Temperature Contours

    Central Plane

    [F]

    Temperature

    near the

    tube is high.

    Flame angled

    towards the center of

    the furnace / away

    from tubes.

    Existing Case Proposed Modification

  • Furnace

    Improvements

    ServicesFlue Gas Temperature Contours

    Plane

    Location

    Existing Case Proposed Modification

    Temperature

    near the tube

    is high.

    [F]

  • Furnace

    Improvements

    ServicesFluid Path Lines: from Fuel Inlet

    Existing Case Proposed Modification

    Outer

    recirculation

    pattern

    [ft/s]

  • Furnace

    Improvements

    ServicesFlame Contours (CO >2000ppm)

    [F]

    Existing Case Proposed Modification

    Colored by Temperature

    [F]

  • Furnace

    Improvements

    ServicesFlame Contours (CO >2000ppm)

    [ft]

    Flame height is14 ft. Flame height is reduce to 9 ft.

    Existing Case Proposed Modification

    Colored by Height

    [ft]

  • Furnace

    Improvements

    ServicesFlame Contours (5% O2)

    [ft] Existing Case Proposed Modification

    Flame

    height

    is16 ft.

    Flame height is

    reduce to 9.8 ft.

    Colored by Height

    [ft]

  • Furnace

    Improvements

    ServicesFlame Contours (3% O2)

    [ft]

    Flame height is 15.2 ft

    at 3% O2.

    Colored by Height

    [ft]

  • Furnace

    Improvements

    ServicesTube Metal Temperatures

    [F]

    Existing Case Proposed Modification

    Hot spots due

    to flame

    impingement.

    TMTs more

    uniform.

  • Furnace

    Improvements

    ServicesTube Heat Flux

    High heat flux

    distribution at

    bottom of the

    tubes

    Existing Case Proposed Modification

    [Btu/hrft2][Btu/hrft2]

  • Furnace

    Improvements

    ServicesCoker Heater

    High tube metal temperature issues

    Fuel gas fired low NOx burners

    www.heatflux.com 30

  • Furnace

    Improvements

    ServicesCoker Heater Geometry

    www.heatflux.com 31

    ProposedExisting

    Burners are

    inclined by

    7.5 towards the walls.

  • Furnace

    Improvements

    ServicesVelocity Vectors

    www.heatflux.com 32

    Expanded View[ft/s]

    Plane at primary tip

  • Furnace

    Improvements

    ServicesVelocity Vectors by Temperature

    www.heatflux.com 33

    [F]

    Plane at primary tip

  • Furnace

    Improvements

    ServicesTube Metal Temperature Contours

    www.heatflux.com 34

    [F]

  • Furnace

    Improvements

    ServicesRefractory Temperature Contours

    www.heatflux.com 35[F]

  • Furnace

    Improvements

    ServicesFlame Shapes (Iso-Surface of

    CO 2000 ppm)

    36Colored by Temperature [F]

    B-4B-1 B-2 B-3

  • Furnace

    Improvements

    ServicesFlow Profiles - Vertical Up Firingvs Inclined Firing

    www.heatflux.com 37

    Inclined Firing Vertical Up Firing

    [ft/s]

  • Furnace

    Improvements

    Services

    Flue Gas Temperature Profiles Vertical Up Firing vs Inclined Firing

    www.heatflux.com 38

    Inclined Firing Vertical Up Firing[F]

  • Furnace

    Improvements

    ServicesFlame Profiles - Vertical Up Firing

    vs Inclined Firing

    www.heatflux.com 39

    Inclined Firing Vertical Up Firing

  • Furnace

    Improvements

    ServicesCrude Heater Horizontal Cabin

    Cabin heater suffering from high tube metal

    temperatures at arch

    Originally 6 large burners-30 MMBtu/hr

    each

    Proposed 36 burners-5 MMBtu/hr each with

    inclined firing mode

  • Furnace

    Improvements

    ServicesFlames Colored by Height

    CO 2000 PPM

    Base Case Proposed Design[ft]

  • Furnace

    Improvements

    ServicesVelocity Vectors - Z-1 Section

    Base Case Proposed Design

    Z-1Z-1

    Z-2 Z-2

    [ft/s]

  • Furnace

    Improvements

    ServicesTemperature Contours at Z Sections

    Base Case Proposed Design[F]

  • Furnace

    Improvements

    ServicesRadiant Tube Temperature

    Contours

    Base Case Proposed Design

    [F]

  • Furnace

    Improvements

    ServicesCrude Heater- Vertical Cylindrical

    Client facing flame impingement and high tube

    metal temperatures in radiant

    section

    FIS recommended inclined burner firing system to eliminate

    flame impingement

    Carried out CFD modeling of the burners and radiant section

    to demonstrate the benefit of the

    inclined burner firing system

    www.heatflux.com 45

  • Furnace

    Improvements

    ServicesExisting Burner Arrangement

    EXISTING FLOOR & PLENUM ARRANGEMENT

    www.heatflux.com 46

  • Furnace

    Improvements

    ServicesInclined Firing System Burner Arrangement

    www.heatflux.com 47

  • Furnace

    Improvements

    Services

    Crude HeaterFloor Design

    www.heatflux.com

  • Furnace

    Improvements

    Services

    Crude HeaterPlenum Chambers

    www.heatflux.com

  • Furnace

    Improvements

    ServicesVelocity Vectors

    Base Case vs Inclined Firing System

    www.heatflux.com 50

    0 ft

    Height in

    Feet

    19 ft

    36 ft

    50 ft

    [ft/sec]

    Existing Case

    with Vertically Fired

    Burners

    Proposed Case

    with Inclined Firing

    System

  • Furnace

    Improvements

    ServicesTemperature ContoursBase vs Inclined Firing System

    Base Case Inclined Firing System

    www.heatflux.com 51

    [F]

  • Furnace

    Improvements

    ServicesTemperature Contours at 10ftBase Case vs Inclined Firing System

    Base Case Inclined Firing System

    At 10 ft At 10 ft

    www.heatflux.com 52

    [F]

  • Furnace

    Improvements

    ServicesTemperature Contours at 15 ft -

    Base Case vs Inclined Firing System

    Base Case Inclined Firing System

    1

    At 15 ft At 15 ft

    www.heatflux.com 53

    [F]

  • Furnace

    Improvements

    ServicesCO Mass Fraction Contours at 10 ftBase Case vs Inclined Firing System

    At 10 ft

    Inclined Firing System

    1

    Base Case

    At 10 ft

    www.heatflux.com 54

    [ppm]

  • Furnace

    Improvements

    ServicesCO Mass Fraction Contours at 15 ft

    Base Case vs Inclined Firing System

    At 15 Ft

    Inclined Firing System

    1

    Base Case

    At 15 Ft.

    www.heatflux.com 55

    [ppm]

  • Furnace

    Improvements

    Services

    Iso Surface of CO MF 2000 PPM Colored by Temperatures

    Base Case vs Inclined Firing System

    Base Case Inclined Firing System

    Top Viewwww.heatflux.com 56

    [F] [F]

  • Furnace

    Improvements

    Services

    Iso Surface of CO Mass Fraction 2000 ppm Colored by Flame Height

    Base Case Inclined Firing

    System

    www.heatflux.com 57

    [ft]

  • Furnace

    Improvements

    ServicesRadiant Wall Temperatures

    Base Design Proposed Design

    For h =100 Btu/ft2h and T= 800 F

    www.heatflux.com 58

    [F]

  • Furnace

    Improvements

    ServicesSummary

    Client reported almost 250 F reduction in tube metal temperatures after the

    revamp.

    Inclined Firing is proven in solving high tube metal temperatures problems

    CFD modeling demonstrated the ability of IFS to improve performance

    FIS is ready to evaluate your heater to determine whether it is a suitable

    candidate for Inclined Firing at no cost. www.heatflux.com 59

  • Furnace

    Improvements

    ServicesDHT Heater

    Installation of 4 burners in inclined firing pattern

    www.heatflux.com 60

  • Furnace

    Improvements

    Services

    DHT HeaterFloor Layout

    www.heatflux.com

  • Furnace

    Improvements

    ServicesSEU Units

    www.heatflux.com 62

    F-4202 F-4201

    1650 2350

    (TYP.)

    3

    (TYP.)

    5.5

    C B

    UR

    NE

    R

    C B

    UR

    NE

    R

    3200 (P.C.D.) 3962 (P.C.D.)

    762 1372

    B.C.D. B.C.D.

    FLOOR PLT. FLOOR PLT.

    L

    L

    C B

    UR

    NE

    R

    C B

    UR

    NE

    RL

    L

  • Furnace

    Improvements

    ServicesVertical Cylindrical Heaters

    Two vertical cylindrical heaters working for almost 3 years with Inclined Firing System

    Reduced fouling and hot spots

    Provided 10% extra capacity

    with Inclined Firing Technology

  • Furnace

    Improvements

    Services

    Reboiler Heaters

    www.heatflux.com

  • Furnace

    Improvements

    Services