IEC61000 TEST EMC SYSTEMS IEC61000-3-2 IEC61000-3-3 IEC61000-3-11 IEC61000-3-12 IEC61000-4-11 IEC61000-4-13 IEC61000-4-29 N4L EMC Test Systems - The most comprehensive ISO17025 Harmonics and Flicker Calibration coverage in the market Newtons4th Ltd N4L EMC Test Soltutions from the worlds leading IEC61000 test system Manufacturer 7949

Upload: phungque

Post on 24-Jun-2018

341 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IEC61000 TEST EMC SYSTEMS - newtons4th.com€¦ · IEC61000 TEST EMC SYSTEMS IEC61000-3-2 IEC61000-3 ... The IEC61000-3-2 and IEC61000-3-12 standards refer to the measurement technicques

IEC61000 TEST EMC SYSTEMSIEC61000-3-2IEC61000-3-3IEC61000-3-11

IEC61000-3-12IEC61000-4-11

IEC61000-4-13IEC61000-4-29

N4L EMC Test Systems - The most comprehensive ISO17025 Harmonics and Flicker Calibration coverage in the market

Newtons4th LtdN4L

EMC Test Soltutions from the worlds leading IEC61000 test system Manufacturer

7949

Page 2: IEC61000 TEST EMC SYSTEMS - newtons4th.com€¦ · IEC61000 TEST EMC SYSTEMS IEC61000-3-2 IEC61000-3 ... The IEC61000-3-2 and IEC61000-3-12 standards refer to the measurement technicques

EMC Test Systems Newtons4th(N4L) design and manufacture a wide range of EMC test systems to meet the needs of modern test laboratories. N4L’s high quality instrumentation, accompanied by customized intuitive test software provide highly accurate measurements presented in a clear and consise manner to the user. Sophisticated reporting functions allow the user to rapidly and efficiently export data to excel, producing detailed, proffessional test reports for end customers.

UKAS ISO17025 Accreditation N4L PPA55xx series of power analyzers and impedance networks provide fully compliant Harmonics and Flicker test solutions, with direct accreditation available via N4L's internal UKAS ISO17025 calibration laboratory. Certified by NPL (National Physical Laboratory) in the UK, the N4L PPA55xx provides reliable, accurate measurements compliant to the latest test standards (IEC61000-3-2/3 and IEC61000-3-11/12).

In combination with an N4L Impedance Network and a compliant AC Source, you will be equipped to provide fully compliant Harmonics and Flicker measurements.

The level and coverage of accreditation available from the N4L UKAS ISO17025 test laboratory is unrivalled in the industry, the scope of accreditation includes the following;IEC61000-4-15: Pinst (Sinusoidal and Rectangular Modulation), Pst, Frequency Changes, Distorted Voltage with Multiple Zero Crossings, Harmonics with Sidebands, Phase Jumps, Rectangular Changes with Duty CycleIEC61000-4-7: Current Harmonic Amplitude

7949

IEC61000-3-2 / IEC61000-3-12 (Current Harmonics)The IEC61000-3-2 and IEC61000-3-12 standards refer to the measurement technicques described within the IEC61000-4-7 measurement standard. IEC61000-4-7 details the exact measurement techniques and principles required of an instrumenta-tion manufacturer. The PPA55x1 complies to all aspects of the IEC61000-4-7 standard, thus the PPA55x1 inherently complies to IEC61000-3-2 and IEC61000-3-12. UKAS ISO17025 accreditation is also available from N4L’s internal ISO17025 accredited labora-tory, this provides the highest level of calibration for an IEC61000-3-2/3-12 harmonics analyzer.

“IECSoft” Software - Harmonic Test InterfaceAn important aspect of any compliant test system is the HMI(Human Machine Interface), N4L have spent many years develop-ing and improving the IEC61000-3-2/12 user interface which has matured into an intuitive, comprehensive analysis and review mechanism for the test engineer. Features such as real time pass/fail flags, live graphical update of limit levels, data point export for complete test “replay”, as well as a thorough reporting function.

Real time update of colour coded graphical display, including active limit indication Percentage of limit view normalises each harmonic result to 100% of limit

Individual Harmonics graphed, providing a deeper understanding of DUT behaviour Unique “Wafeform Analysis” mode, providing automated pass/fail result

Page 3: IEC61000 TEST EMC SYSTEMS - newtons4th.com€¦ · IEC61000 TEST EMC SYSTEMS IEC61000-3-2 IEC61000-3 ... The IEC61000-3-2 and IEC61000-3-12 standards refer to the measurement technicques

Harmonics Export FunctionThe export function integrated into the IECSoft EMC test software suite is a vital aspect of any EMC compliance measurement. IECSoft provides a comprehensive export function directly to excel, this enables the user to edit the report as required to meet internal procedural requirements.

Signature

Results Phase 1: FAIL - AVERAGE & PEAK

Lab Name N4LLocation Leics, UKNotes

Minimum Current 3ATest Duration 2.5 minutes

Additional Test DetailsOperator Applications

Max Power 288.051 WMax F.Current 1.277 AAverage F.Current 874.781 mA

Additional Test InformationMeasured Power Factor 0.6199Max Current THD 17.75%Max THC 0.0536A

Rated Frequency 50.000 Hz 49.999 HzRated Power 400.000 W 181.809 W

Rated Voltage 230.000 V 230.069 VRated Current 4.600 A 992.193 mA

Impedance Network ID 91G-11335Test Conditions

User Entered Measured

Equipment Under TestBrand UnbrandedModel TRW211WSSerial 3434908

Source Settling Time 10 sTest Settings

Class Class DMode Measure

Source Serial 91J-00011Source Frequency 50.000 HzSource Voltage RMS 230.000 V

Instrument Last Calibrated 02nd February 2015Instrument Version StandardSource Model N4A06

Instrument DetailsInstrument Model PPA5511Instrument Serial 162-04043Instrument Firmware 2.138

04th May 2016 - 08:43:55 Page 1/15 IECSoft v2_4f

IEC61000-3-2:2014Fluctuating Harmonics

Test # Test #2 1 3 PASS3 1 3 PASS4 1 3 PASS5 1 3 PASS6 3 1 PASS7 1 3 PASS8 1 3 PASS9 1 3 PASS10 1 3 PASS11 1 3 PASS12 1 3 PASS13 1 3 PASS14 1 3 PASS15 1 3 PASS16 1 3 PASS17 3 1 PASS18 1 3 PASS19 3 1 PASS20 1 3 PASS21 1 3 PASS22 1 3 PASS23 1 3 PASS24 3 1 PASS25 3 1 PASS26 3 1 PASS27 1 3 PASS28 1 3 PASS29 1 3 FAIL30 1 3 PASS31 1 3 PASS32 3 1 PASS33 3 1 FAIL34 1 3 PASS35 1 3 PASS36 1 3 PASS37 1 3 PASS38 1 3 PASS39 3 1 PASS40 1 3 PASS

Key: AllowanceGoodOKPoorFail

Maximum Difference allowed in AmpsThe difference is less than 50% of the allowanceThe difference is between 50% of the allowance and 75% of the allowanceThe difference is between 75% of the allowance and 100% of the allowanceThe difference has exceeded the allowance

0.000231 0.000275 0.001342 0.0000440 0 0 0

0.000334 0.001104 0.001415 0.000770 0 0 0

0.000607 0.000843 0.001496 0.0002360 0 0 0

0.000872 0.002616 0.001586 0.0017440 0 0 0

0.00464 0.005309 0.001689 0.000670 0.000001 0 0.000001

0.003537 0.006486 0.001805 0.0029490 0 0 0

0.006877 0.007284 0.001939 0.0004070 0 0 0

0.008008 0.008477 0.002094 0.0004690.000023 0.000051 0 0.000028

0.009389 0.010102 0.002276 0.0007130.00005 0.000069 0 0.00002

0.010707 0.010911 0.002493 0.0002040 0 0 0

0.011593 0.011857 0.002755 0.0002640 0 0 0

0.012738 0.012796 0.00308 0.0000580 0 0 0

0.013833 0.014275 0.00349 0.0004420 0 0 0

0.014495 0.014659 0.004027 0.0001640 0 0 0

0.01351 0.013681 0.004759 0.0001710 0 0 0

0.01171 0.012132 0.006799 0.0004220 0.000001 0 0.000001

0.013636 0.014261 0.013598 0.0006250 0 0 0

0.01827 0.018691 0.025836 0.0004210 0.000014 0 0.000014

0.026425 0.026948 0.046233 0.0005230 0 0 0

Average (A) Average (A) Allowance (A) Difference (A)0 0.000004 0 0.000004

Model TRW211WSSerial 3434908

Harmonic Difference

Harmonic Lowest Highest Limit Status

Instrument Serial 162-04043Instrument Firmware 2.138

Equipment Under TestBrand Unbranded

04th May 2016 - 08:43:55 Ph:1 Page 2/15 IECSoft v2_4fIEC61000-3-2:2014 Fluctuating Harmonics

Instrument DetailsInstrument Model PPA5511

IEC61000-3-3 / IEC61000-3-11 (Flicker IEC61000-4-15)N4L provide complaint measurements to the latest test protocols/limits specified within IEC61000-3-3 and IEC61000-3-11. The PPA55x1 Precision Power Analyzer complies fully with IEC61000-4-15 which dictates both the hardware and firmware require-ments for compliance to IEC61000-3-3/11. N4L are currently the only Flickermeter manufacturer in the world* to offer complete coverage of the IEC61000-4-15 standard with ISO17025 accreditation. This optional ISO17025 calibration procedure is performed within N4L’s ISO17025 UKAS calibration laboratory and covers all aspects of the IEC Flicker test standards.

“IECSoft” Software Flicker Test InterfaceIECSoft’s Flicker measurement mode incorporates an intuitive step by step style setup procedure, guiding the user through the test configuration. Remote control of the N4L N4A AC Power Source is handled automatically by IECSoft, test procedures include selection of d[t] parameters and calculation of Ztest if necessary. Pinst, IFS, PST, PLT, D, Dmac, Dc and Tmax are also updated dur-ing any test.

IFS recorded real time, for in depth post test analysis Real time display indicating current test status

Page 4: IEC61000 TEST EMC SYSTEMS - newtons4th.com€¦ · IEC61000 TEST EMC SYSTEMS IEC61000-3-2 IEC61000-3 ... The IEC61000-3-2 and IEC61000-3-12 standards refer to the measurement technicques

Every data return is recorded and saved within the IECSoft software package Classifier Probability Graph

Wait command indicated by the “Inrush test” user interface “Start DUT” Command to prompt user to operate manual switch

Inrush Testing (dmax)For products utilising manual switching as a method of initiating and ending operation, a “dmax” test known as the “Inrush test” is required. This involves a succession of 24 switching events that are recorded and the arithmetic mean (excluding the highest and lowest dmax values) is calculated. An intuitive user interface has been developed for this task which guides the test engineer through the process and provides prompts to perform the switching event. Statistical analysis is also automated within the soft-ware, removing this burden from the user. This results in reduced test times and eliminates the risk of a mathematical error.

Flicker Export FunctionThe flicker export function exports all recorded data including DUT test data and flicker results, export options include the ability to lock the exported spreadsheet as well as formatting the report into a single or multiple worksheet. The user also has the ability to import their own company logo, which is exported within the final report.

Notes

Signature

Results Phase1: PASS

Additional Test DetailsOperator ApplicationsLab Name N4LLocation Leics, UK

D max 0.0428% (Limit: 4%)T max 0.0000 s (Limit: 0.5 s)DC max 0.0008% (Limit: 3.3%)

Rated Frequency 50.000 Hz 50.000 HzRated Power 400.000 W N/A

Rated Voltage 230.000 V 229.726 VRated Current 4.600 A N/A

Impedance Network ID 91G-11335Test Conditions

User Entered Measured

Equipment Under TestBrand UnbrandedModel TRW211WSSerial 3434908

Minimum Current 10APST 1.00 minutesPLT 3 PSTs

Source Settling Time 10 sTest Settings

Class VoltageMode Normal - 4%

Source Serial 91J-00011Source Frequency 50.000 HzSource Voltage RMS 230.000 V

Instrument Last Calibrated 02nd February 2015Instrument Version StandardSource Model N4A06

Instrument DetailsInstrument Model PPA5511Instrument Serial 162-04043Instrument Firmware 2.138

05th May 2016 - 14:22:14 Page 1/3 IEC Soft V2.4f

IEC61000-3-3:2013 Ed.3.0Flickermeter

Export user interface

Page 5: IEC61000 TEST EMC SYSTEMS - newtons4th.com€¦ · IEC61000 TEST EMC SYSTEMS IEC61000-3-2 IEC61000-3 ... The IEC61000-3-2 and IEC61000-3-12 standards refer to the measurement technicques

IEC61000-4-11 - Voltage Dips, Short Interruptions and Voltage VariationsIEC61000-4-11 defines test protocols and measurement techniques for electrical and electronic equipment connected to low-voltage supply networks. IECSoft provides an easy to configure user interface, in which a number of product configurations can be added to the test sequences. Covering all classes, including class “X” - the software offers the flexibility required for product committees to define a wide range of test levels.

Test overview interface - Detailing the class, number of sequences and test details Configuration interface - Select class, product details and nominal voltage/frequency

Test sequence - AC Source ON awaiting manual initiation of test sequence. Test Complete - DUT passed

Signature

Lab Name N4LLocation Leics, UKNotes

Rated Frequency 50-60 Hz Rated Power 400W W

Additional Test DetailsOperator Applications

Impedance Network ID 91G-11335Rated Voltage 230 V Rated Current 4.6A A

Equipment Under TestBrand UnbrandedModel TRW211WSSerial 3434908

Source DetailsSource Model N4A06Source Serial 91J-00011Source Firmware 1.11

05th May 2016 - 14:51:55 Page 1/5 IEC Soft V2.4f

IEC61000-4-11:2004Voltage Dips, Short Interruptions and Voltage

i i

Source Serial 91J-00011Source Firmware 1.11

Equipment Under TestBrand Unbranded

05th May 2016 - 14:51:55 Page 2/5 IEC Soft V2.4fIEC61000-4-11: Voltage Dips, Short Interruptions and Voltage Variations

Instrument DetailsSource Model N4A06

Input Port 1AOperating Mode StandardConnections N/A

Model TRW211WSSerial 3434908

Equipment Under TestEUT Type Fan

General Notes

Configuration SettingsNominal Voltage (UT) 230.00 V Frequency 50.00 Hz

Cables L-N-PEPeripherals N/ASetup Notes Max Load

Duration in cycles 0.5Test Notes No effect on product operation

Test Results Pass

Sequence Class 2Test Results 1/4

Test Type DipTest Level 0.00%

Test report for IEC61000-4-11

IEC61000-4-11 Test Details

IEC61000-4-15 - Flicker SimulationN4A power sources are able to simulate flicker waveforms in order to test flickermeters for correct operation. This mode can also be used to create an environment in which products are tested for susceptibility against flicker on the supply line, this is useful as voltage modulations on the supply line can cause instability within input regulation circuitry.

Page 6: IEC61000 TEST EMC SYSTEMS - newtons4th.com€¦ · IEC61000 TEST EMC SYSTEMS IEC61000-3-2 IEC61000-3 ... The IEC61000-3-2 and IEC61000-3-12 standards refer to the measurement technicques

IEC61000-4-13 - Harmonic and Interharmonic SusceptibilityAs mains supply lines can suffer from harmonic and interharmonic interference, IEC61000-4-13 defines the harmonic and in-terharmonic levels upon which products must be tested. IECSoft provides a simple user interface to create test programmes for each class of product.

IEC61000-4-13 EUT Setup interface including class selection Test programme details including harmonic combination and frequency sweep

IEC61000-4-13 Test Schedule Sweep in Frequency test in progress

WaveformsAs mains supply lines can suffer from harmonic and interharmonic interference, IEC61000-4-13 defines the harmonic and in-terharmonic levels upon which products must be tested. IECSoft provides a simple user interface to create test programmes for each class of product.

Power Source SchematicN4A Advanced Power Amplifiers feature proprietary noise suppression analgoue electronics known as "6 leg modulation" topology which produces an output waveform during high loads with less than 0.1% THD. This level of distortion has only previously been possible with linear power sources.

EMC Input Filter Recti�er

StorageCapacitor Inverter Power Filter

EMCOutput

Filter

Power OUTPUT

PowerInput

3PH + N+PE

N

Page 7: IEC61000 TEST EMC SYSTEMS - newtons4th.com€¦ · IEC61000 TEST EMC SYSTEMS IEC61000-3-2 IEC61000-3 ... The IEC61000-3-2 and IEC61000-3-12 standards refer to the measurement technicques

IEC61000 EMC TEST SYSTEM SPECIFICATION:PPA55x1 Harmonics and Flicker Analyzer

PPA55x1 Harmonics and Flicker Analyzer

Bandwidth

DC,10mHz ~ 1MHz - PPA55x1 - Low Impedance Shunt (50Arms)

IEC61000 Voltage Input

Range 300mVpk ~ 3000Vpk(1000Vrms) in 9 ranges

0.01% Rdg+0.038% Rng+(0.004%×kHz)+5mV

Range 300µVpk ~ 3Vpk in 9 ranges 【BNC connector 3Vpk max input】

0.01%Rdg+0.038%Rng+(0.004%×kHz)+3µV

IEC61000-3-2 Compliant Current Input, including Harmonic Accuracy

Low Impedance (Fully Compliant) 3mΩ Max 50Arms

100mApk ~ 1000Apk(50Arms)

0.01% Rdg+0.038% Rng+(0.004%×kHz)+ 900µA

External input(External shuntCurrent sensor)

BNC Connector (Max input 3Vpk)

300µVpk ~ 3Vpk in 9 ranges

0.01% Rdg+0.038% Rng+(0.004%×kHz)+ 3µV

Phase Accuracy

0.005deg+(0.01deg×kHz)【PPA5500-LC(10Arms), PPA5500(30Arms)】 0.01deg+(0.02deg×kHz)【PPA5500-HC(50Arms)】

IEC61000-3-3 + IEC61000-3-11 Flicker Accuracy

Pst 3%

Plt 3%

Pinst 5%

d(c), d(max),

d(t)3%

IEC61000-3-2 + IEC61000-3-12 Harmonics Accuracy

0.1% of rms current

Power Accuracy

[0.03%+0.03%/pf+(0.01%×kHz)/pf] Rdg+0.03%VA Rng

40-400Hz [0.03%+0.03%/pf+(0.01%×kHz)/pf] Rdg+0.02%VA Rng

General

Crest Factor 20(Voltage and Current)

Sample Rate 2.2Ms/s on all channels, No-Gap

IEC ModesIEC61000 Harmonics and Flicker (PPA5500), IEC62301 Standby

Power

Application Modes

PWM Motor Drive, Ballast, Inrush, Power Transformer, Standby Power,

Fluctuating Harmonics, Flicker Meter

CMRR - Common Mode Rejection Ratio

250V @ 50Hz - ≥ 1mA (150dB)

100V @ 100kHz - ≥ 3mA (130dB)

Communication Ports

RS232 Baud rate up to 38.4kbps, RTS/CTS flow control

LAN 10/100 Base-T Ethernet auto sensing

GPIB IEEE488.2 compatible

USB USB 2.0 and 1.1 compatible

Analogue Output

Bipolar ±10V(BNC)

Speed Input BNC Bipolar±10V or Pulse count 1Hz to 1MHz 0.01% Rdg

Torque BNC Bipolar±10V or Pulse count 1Hz to 1MHz 0.01% Rdg

Sync 4 ~ 6 Phase measurement (Master/Slave)

Extension 4 ~ 6 Phase (Master/Slave) + Auxiliary

Standard Accessories

Leads Power, RS232, USB, GPIB

Connection Cables

36A 1.5m long 4mm stackable terminals1x red, 1x yellow and 2x black per phase (1x red, 1x black with HC

version)

Connection Clips4mm terminated aligator clips - 1x red, 1x yellow and 2x black

per phase (1x red and 1x black per phase with PPA5500-HC version)

CD-ROMIECSoft, CommView2 (RS232/USB/LAN), Command line, Script

based communication software

DocumentsUser manual, Communications manual, Calibration certificate,

Quick start guide

Mechanical/Environmental

Display 320×240 dot full colour TFT, White LED Backlit

Dimensions 130H×400W×315D mm excluding feet

Weight 5.4kg(1 Phase), 6kg(3 Phase)

Safety Isolation 1000Vrms or DC(CATII), 600Vrms or DC(CATIII)

Power supply 90 ~ 265Vrms, 50 ~ 60Hz, 40VAmax

IMPEDANCE NETWORK SPECIFICATIONIMP161/3(16Arms) , IMP321/3(32Arms) and IMP753(75Arms)

models available

IMP161/3 Fully Compliant to IEC61000-3-3

IMP321/3 & IMP753

Fully Compliant to IEC61000-3-11

Impedance Specification

RA = 0.24Ω jXA = 0.15Ω @ 50HzRN = 0.16Ω jXN = 0.10Ω @ 50Hz

Current Rating

IMP16x 16Arms per phase

IMP753 75Arms per phase

Measurement Parameters

W, VA, Var, pf, V & A - rms, rectified mean, AC, DC, Peak, Surge, Crest Factor, Form Factor, Star to Delta Voltage

Frequency (Hz), Phase (deg), Fundamentals, Impedance

Harmonics, THD, TIF, THF, TRD, TDD

Integrated Values, Datalog, Sum and Neutral values

Datalog - Up to 4 user selectable measurement functions (60 with optional PC

software)

Datalog Window No-Gap analysis, Minimum window 2ms

Memory 10M records into flash RAM (Non-Volatile) PPA5531 Harmonics and Flicker Analyzer

Page 8: IEC61000 TEST EMC SYSTEMS - newtons4th.com€¦ · IEC61000 TEST EMC SYSTEMS IEC61000-3-2 IEC61000-3 ... The IEC61000-3-2 and IEC61000-3-12 standards refer to the measurement technicques

AC POWER SOURCE SPECIFICATIONN4A03 (1 Phase) N4A06 (1 Phase) N4A18 (3 Phase) N4A30 (3 Phase) N4A67 (3 Phase)

Nominal Output Power 3,000VA 6,000VA 18,000VA 30,000VA 67,500kVA

Compliant Standards

IEC61000-3-2:2014 (Single Phase)IEC61000-3-3:2013 (Single Phase)

IEC61000-4-11:2004 (Single Phase)IEC61000-4-13:2009 (Single Phase)*IEC61000-4-29:2001 (Single Phase)

IEC61000-3-12:2005IEC61000-3-11:2000

IEC61000-4-11:2004 (Single/Three Phase)IEC61000-4-13:2009 (Single/Three Phase)*IEC61000-4-29:2001 (Single/Three Phase)

Output

Output Voltage (AC) 0-300Vrms

Output Voltage (DC) 0-425V DC

Maximum Continuous Output Power (AC)

3000VA 6000VA 18,000VA 30,000VA 67,500VA

Maximum Inrush (3 Second) Output Power (DC)

6000VA 12000VA 36,000VA 60,000VA 90,000VA

Maximum Output Current (Continuous)

10Arms 20Arms 20Arms (Per Phase) 32Arms (Per Phase) 75Arms (Per Phase)

Maximum Output Current (Inrush)

20Arms 40Arms 40Arms (Per Phase) 64Arms (Per Phase) 100Arms (Per Phase)

Output Frequency DC - 1kHz DC - 1kHz DC - 1kHz DC - 1kHz DC - 1kHz

Min Slew Rate 3V/us 3V/us 3V/us 3V/us 3V/us

Output Voltage Stability

Better than 0.1%

Output Voltage Accuracy

Better than 0.5%

THD Better than 0.3%*

Output Noise <500mVrms

Recovery Time of Output Waveform

Better than 50us

Max Compensated drop on wires (w.r.t voltage setting)

5%

Recovery Time of Drop on Wires

Less than 200ms

Maximum Crest Factor [Inrush Imax*1.41]/RMS Load Current

General

Dimensions 281mm x 471mm x 513mm 1785mm x 930mm x 755mm 1785mm x 930mm x 755mm 1800mm x 1200mm x 800mm

Weight 30kg 45kg 740kg 1300kg

Input Voltage 230V AC +/- 10% 1PH 400V AC +/- 10% 3PH

Input Frequency 45-65Hz

Operating Temperature

0-35degC

Input Current 24Arms 16Arms Phase / 27A Neutral60A continuous 120A inrush

/ Phase80A continuous 160A inrush

/ Phase160A continuous 220A

inrush / Phase

Efficiency Better than 80%

IMP163 3 Phase 16Arms/Phase Impedance Network

*Pre-Compliant due to rise/fall time of generator

Page 9: IEC61000 TEST EMC SYSTEMS - newtons4th.com€¦ · IEC61000 TEST EMC SYSTEMS IEC61000-3-2 IEC61000-3 ... The IEC61000-3-2 and IEC61000-3-12 standards refer to the measurement technicques

7949

Newtons4th Ltd 1 Bede Island Road

LeicesterLE2 7EA

UK Phone: +44 (0)116 230 1066

Fax: +44 (0)116 230 1061Email: [email protected]: www.newtons4th.com

copyright © 2010-2016 Newtons4th Document ref: EMC-SYSTEMS/1

Newtons4th Newtons4th Ltd (abbreviated to N4L) was established in 1997 to design, manufacture and support innovative electronic equipment to a worldwide market, specialising in sophisticated test equipment particularly related to phase measurement. The company was founded on the principle of using the latest technology and sophisticated analysis techniques in order to provide our customers with accurate, easy to use instruments at a lower price than has been traditionally associated with these types of measurements

All specifications at 23˚C ± 5˚C . These specifications are quoted in good faith but Newtons4th Ltd reserves the right to amend any specification at any time without notice

Contact your local N4L Distributor for further details

Distributed By :

Flexibility in our products and an attitude to providing the solutions that our customers really want has allowed us to develop many innovative functions in our ever increasing product range

Overview of IEC61000 Test Systems

IEC61000 Test Systems

System Configuration

Overall System Description Single Phase 16A IEC61000 EMC Test SystemSingle+Three Phase 16A IEC61000 EMC Test System

Single+Three Phase up to 75A IEC61000 EMC Test System

Power Source N4A06 N4A18 N4A67

Harmonics and Flicker Analyzer

PPA5511 Combined Harmonics and Flicker + Power Analyzer

PPA5531 Combined Harmonics and Flicker + Power Analyzer

PPA5531 Combined Harmonics and Flicker + Power Analyzer

Optional Impedance Network (For compliant Flicker testing)

IMP161 IMP163 IMP753

Standards (Limits)

IEC61000-3-2:2014 (Single Phase)IEC61000-3-3:2013 (Single Phase)IEC61000-4-11:2004 (Single Phase)IEC61000-4-13:2009 (Single Phase)IEC61000-4-29:2001 (Single Phase)

IEC61000-3-2:2014 (Single/Three Phase)IEC61000-3-3:2013 (Single/Three Phase)IEC61000-4-11:2004 (Single/Three Phase)IEC61000-4-13:2009 (Single/Three Phase)IEC61000-4-29:2001 (Single/Three Phase)

IEC61000-3-12:2005IEC61000-3-11:2000IEC61000-4-11:2004 (Single/Three Phase)IEC61000-4-13:2009 (Single/Three Phase)IEC61000-4-29:2001 (Single/Three Phase)

Measurement StandardsIEC61000-4-7IEC61000-4-15

IEC61000-4-7IEC61000-4-15

IEC61000-4-7IEC61000-4-15

Output Power 6kVA 18kVA 67kVA

Software Included IECSoft IEC61000 Test Suite

AccreditationOptional UKAS ISO17025 IEC61000 Harmonics and Flicker Certifcation of

Optional UKAS ISO17025 IEC61000 Harmonics and Flicker Certifcation of PPA5531

Optional UKAS ISO17025 IEC61000 Harmonics and Flicker Certifcation of PPA5531