high efficiency condensing gas boilers - triangle tube efficiency condensing gas boilers l 60 second...

4
Featuring ACVMax Control with: High Efficiency Condensing Gas Boilers l 60 Second Set-up Based on Previous TriMax Platform l Integrated Cascade Function for up to 6 Boilers l Optional LonWorks ® and BACnet BMS ® Gateway Two Outdoor Reset Curves / Set Points l Multiple Zone Control l Multiple Circulator Control l 439 Stainless Steel Fire Tube Heat Exchanger l ASME Stamped Heat Exchanger l 95% AFUE l Turndown ratios up to 5.5:1 l Low Pressure Drop with Proven Performance l 2” to 4” Venting l Multiple Venting Termination Options l Low NOx - 2012 SCAQMD Certified l 7 Models from 80 to 399 MBH l 5 Year Limited Parts Warranty l 10 Year Limited Heat Exchanger Warranty l 5 & 10 Year Extended Warranty Options

Upload: trankhue

Post on 28-Apr-2018

217 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: High Efficiency Condensing Gas Boilers - Triangle Tube Efficiency Condensing Gas Boilers l 60 Second Set-up Based on Previous TriMax Platform ... Next Generation Fire Tube Heat Exchanger

Featuring ACVMax Control with:

High Efficiency Condensing Gas Boilers

l 60 Second Set-up Based on Previous TriMax Platforml Integrated Cascade Function for up to 6 Boilersl Optional LonWorks® and BACnet BMS® Gateway Two Outdoor Reset Curves / Set Pointsl Multiple Zone Controll Multiple Circulator Control

l 439 Stainless Steel Fire Tube Heat Exchangerl ASME Stamped Heat Exchangerl 95% AFUEl Turndown ratios up to 5.5:1l Low Pressure Drop with Proven Performancel 2” to 4” Ventingl Multiple Venting Termination Optionsl LowNOx-2012SCAQMDCertifiedl 7 Models from 80 to 399 MBHl 5 Year Limited Parts Warrantyl 10 Year Limited Heat Exchanger Warrantyl 5 & 10 Year Extended Warranty Options

Page 2: High Efficiency Condensing Gas Boilers - Triangle Tube Efficiency Condensing Gas Boilers l 60 Second Set-up Based on Previous TriMax Platform ... Next Generation Fire Tube Heat Exchanger

Prestige - Leader in Ser viceabi l i ty

ACVMax Control

60 Second Set-Up• Choose from 6 standard heating applications to set up the boiler in 60 seconds or less. • Finned Tube Baseboard • High Mass Radiant • Cast Iron Baseboard • Low Mass Radiant • Radiators • Fancoil• Preconfiguredforindirecthotwaterapplications

Integrated CascadeJoins up to 6 boilers: Master boiler automatically recognizes linked boilers: Meets simultaneous DHW & Space Heating calls: Full Parallel Modulation: Automatic Duty Cycling.

Multiple Zone Control• Accepts 2 space heating calls with independent outdoor reset curves• Simultaneously heat dual temperature heating systems with built-in mixing valve control• Manage up to 2 space heating zones and 1 DHW zone without an external zone control panel

Multiple Circulator Control• Presetsallowquickconfigurationof4circulatoroutputsfortheapplication• Eachcirculatoroutputisfullyconfigurableforcustomapplications

Intelligent TroubleshootingDescribes lockouts in plain english and suggests solutions: Stores last 8 errors. Records sensor readings for 24hours.

Next Generation Fire Tube Heat ExchangerHigh Water Content • Provides stable temperature control •Lowsensitivitytowaterflowchanges • Reduces short cycling • Adapts to large or small heating loads

Unique Geometry • Designed for maximum reliability with low thermal stress •Improvedwaterflowformaximumheattransfer •439StainlessSteelwithtitaniumforcorrosionresistance •Polypropylenecondensatepanandflueresistscorrosion

Reliable Low Maintenance Design • Self cleaning design washes away combustion debris • 12 year history of reliable performance • High performance burner design • Low pressure drop allows piping directly to the system • ASME Stamped

Page 3: High Efficiency Condensing Gas Boilers - Triangle Tube Efficiency Condensing Gas Boilers l 60 Second Set-up Based on Previous TriMax Platform ... Next Generation Fire Tube Heat Exchanger

Prestige - Leader in Contractor Fr iendly Features

Prestige Solo

Polypropylene Flue and Condensate PanEliminates corrosion from condensate

Test Ports in both Flue and Air Connections

Integrated Check Valve - To eliminateflue gas blow back in negative pressure locations

Offset Blower with quickconnect to minimize heatload and ease maintenance

Sound AttentuatedAir Inlet

ACVMax Display Module

Industry LeadingFire tube heatexchanger

Cast Aluminum burner plate withintegrated angled sight glass

Single piece gasket and insulation to reduceparts & ease maintenance

Swing Out Electrical Panel Permits quick access to boiler internals

The Widest Range of Venting and Termination Options

Venting-2”,3”,and4”diametersdependingonmodel- PVC,CPVC, SS and Polypropylene materials- Flexible Polypropylene for chimney chases

-Concentric(399only)ortwinpipe- Extended vent lengths up to 100 feet

-CommonVentformultipleboilers(399only)

Terminations- Traditional PVC/CPVC/PP/SS piping elbows

- Flush-mount PVC for twin pipes- Flush-mount Stainless Steel for twin pipes

- Single hole Concentric Termination for twin pipes-HorizontalConcentricTermination(399only)

-HorizontalandVerticalCommonVentTerminations(399only)

Prestige - Leader in Contractor Fr iendly Features

Page 4: High Efficiency Condensing Gas Boilers - Triangle Tube Efficiency Condensing Gas Boilers l 60 Second Set-up Based on Previous TriMax Platform ... Next Generation Fire Tube Heat Exchanger

p f

Blackwood NJ 08012One Triangle LaneTriangle Tube www.triangletube.com

856.228.3584856.228.8881

PrestigePerformance Specifications

Boiler Model

FuelInput

Modulation MBH

AFUE

DOEHeating

Capacity MBH

TurndownRatio

Net AHRIRating MBH

Water Volume

Gal.

Boiler Model

Supply/ReturnConnections

GasConnections

Vent/AirDiameter

DimensionsD x W x H

WeightLbs

95.1%* 7.4Solo 399 NaturalPropane

72.5 to 399 379 3305.5 : 1

4.5

Solo 299 NaturalPropane

72.5 to 299 278 24295% 7.4

Solo 250 NaturalPropane

43.6 to 240 222 19395% 5.5 : 1

4.1 : 1

4

Solo 175 NaturalPropane

30.9 to 170 157 13795% 5.3

Solo 155 NaturalPropane

27.8 to 153 142 12395% 5.5 : 1

5.5 : 1

2.1

Solo 110 NaturalPropane

20 to 110 102 8995% 2.1

Solo 80 NaturalPropane

16 to 80 74 6495% 5.0 : 1

5.5 : 1

103

Solo 110 1" 1/2" 3" 17-5/16" x 19-3/4" x 36-9/16" 103

Solo 80 1" 1/2" 3" 17-5/16" x 19-3/4" x 36-9/16"

118

Solo 175 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16" 128

Solo 155 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16"

140

Solo 299 1-1/2" 1" 4" 23-5/8" x 24-7/8" x 39-3/8" 210

Solo 250 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16"

216Solo 399 1-1/2" 1" 4" 23-5/8" x 24-7/8" x 39-3/8"

Connections/Dimensions/DataBoiler Model

FuelInput

Modulation MBH

AFUE

DOEHeating

Capacity MBH

TurndownRatio

Net AHRIRating MBH

Water Volume

Gal.

Boiler Model

Supply/ReturnConnections

GasConnections

Vent/AirDiameter

DimensionsD x W x H

WeightLbs

95.1%* 7.4Solo 399 NaturalPropane

72.5 to 399 379 3305.5 : 1

4.5

Solo 299 NaturalPropane

72.5 to 299 278 24295% 7.4

Solo 250 NaturalPropane

43.6 to 240 222 19395% 5.5 : 1

4.1 : 1

4

Solo 175 NaturalPropane

30.9 to 170 157 13795% 5.3

Solo 155 NaturalPropane

27.8 to 153 142 12395% 5.5 : 1

5.5 : 1

2.1

Solo 110 NaturalPropane

20 to 110 102 8995% 2.1

Solo 80 NaturalPropane

16 to 80 74 6495% 5.0 : 1

5.5 : 1

103

Solo 110 1" 1/2" 3" 17-5/16" x 19-3/4" x 36-9/16" 103

Solo 80 1" 1/2" 3" 17-5/16" x 19-3/4" x 36-9/16"

118

Solo 175 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16" 128

Solo 155 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16"

140

Solo 299 1-1/2" 1" 4" 23-5/8" x 24-7/8" x 39-3/8" 210

Solo 250 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16"

216Solo 399 1-1/2" 1" 4" 23-5/8" x 24-7/8" x 39-3/8"

Couple to Industry Leading Indirect Water Heater FamilyTank in Tank Design (No Coils – Maintenance Free)

l Unparalleled performance allows 25-50% smaller size than competitorsl Fastest recovery - recovery in 30%-40% less time than competitorsl Stainless Steel constructionl Residential Smart tanks have limited lifetime warrantyl Comfort Tanks have 10 year limited warrantyl 7 sizes in Smart familyl 2 sizes in Comfort family

Triangle Tube reserves the right to make product changes or improvements at any time without notice.

*Thermal Efficiency

2015

-15

Pres

tige

Solo

ACV

Max

Lite

ratu

re -

03/0

1/20

16