HARRIS COUNTY HOUSING AUTHORITY 8933 Interchange Houston, Texas 77054 | 713.669-4514 P AMENDMENT OF SOLICITATION ADDENDUM # 3 DATE: 06-03-16 ISSUED BY: Harris County Housing Authority AMENDMENT TO SOLICITATION NUMBER: IFB #16-04 Fenix Estates Phase I & II THE DATE AND TIME SPECIFIED FOR RECEIPT OF PROPOSALS IS FRIDAY, JUNE 24, 2016, 2:00 PM CST. THE SOLICITATION MENTIONED ABOVE IS AMENDED AS SET FORTH BELOW. PROPOSERS MUST ACKNOWLEDGE RECEIPT OF THIS AMENDMENT PRIOR TO THE HOUR AND DATE SPECIFIED FOR RECEIPT OF PROPOSALS BY SIGNING THIS FORM BELOW. ____________________ ____________________ Proposer/Respondent Date ____________________ Signature

Upload: tranbao

Post on 06-Jun-2018

226 views

Category:

Documents


0 download

TRANSCRIPT

HARRIS COUNTY HOUSING AUTHORITY 8933 Interchange Houston, Texas 77054 | 713.669-4514 P

AMENDMENT OF SOLICITATION

ADDENDUM # 3 DATE: 06-03-16

ISSUED BY: Harris County Housing Authority

AMENDMENT TO SOLICITATION NUMBER: IFB #16-04

Fenix Estates Phase I & II

THE DATE AND TIME SPECIFIED FOR RECEIPT OF PROPOSALS IS

FRIDAY, JUNE 24, 2016, 2:00 PM CST.

THE SOLICITATION MENTIONED ABOVE IS AMENDED AS SET FORTH

BELOW. PROPOSERS MUST ACKNOWLEDGE RECEIPT OF THIS

AMENDMENT PRIOR TO THE HOUR AND DATE SPECIFIED FOR RECEIPT

OF PROPOSALS BY SIGNING THIS FORM BELOW.

____________________ ____________________

Proposer/Respondent Date

____________________

Signature

Addendum No. 3

1500 McGowen St. Ste 200

Houston, Texas 77004

Phone: (713) 524-4202 Fax: (713) 524-4071

Page 1 of 3

ADDENDUM NO. 3

DATE: June 2, 2016

PROJECT: Fenix Estates Apartments Phase I and II.

LOCATION: 3815 Gulf Freeway Houston, Texas 77004.

PROJECT NO. 032415N

DISTRIBUTION:

DELIVERED VIA:

NO. PAGES: 2

PREPARED BY: Smith & Company Architects, Inc

This addendum forms a part of the Specifications for the Fenix Estates Apartments Phase I and II

Project # 032415N for Harris County Housing Authority documents posted on May 20, 2016, for

the subject project and modifies/add to them as noted below.

CHANGES TO PROJECT MANUAL

POINT OF CLARIFICATION

1. Any subcontractor that submits a bid beyond the bond threshold would need

to have a bid bond.

SPECIFICATIONS

1. Add attached pre bid meeting sign in sheet dated May 31, 2016.

2. Delete Section 283111 – DIGITAL ADDRESSABLE FIRE ALARM SYSTEM

dated May 20, 2016 and replace with attached section 283111 dated June 2, 2016.

DRAWINGS PHASE I

1. Delete Sheet A0.00 COVER SHEET dated May 20, 2016 and replace with

attached sheet A0.00 dated June 2, 2016.

6/2/16

Addendum No. 3

1500 McGowen St. Ste 200

Houston, Texas 77004

Phone: (713) 524-4202 Fax: (713) 524-4071

Page 2 of 3

2. Delete Sheet E1.12 – Electrical Power Plan – Building 1 Level 2 dated May 20,

2016 and replace with attached sheet E1.12 dated June 2, 2016.

3. Delete Sheet E1.13 – Electrical Power Plan – Building 1 Level 3 dated May 20,

2016 and replace with attached sheet E1.13 dated June 2, 2016.

4. Delete Sheet E1.14 – Electrical Power Plan – Building 1 Level 4 dated May 20,

2016 and replace with attached sheet E1.14 dated June 2, 2016.

5. Delete Sheet E1.21 – Electrical Power Plan – Building 2 Level 1 dated May 20,

2016 and replace with attached sheet E1.21 dated June 2, 2016.

6. Delete Sheet E1.22 – Electrical Power Plan – Building 2 Level 2 dated May 20,

2016 and replace with attached sheet E1.22 dated June 2, 2016.

7. Delete Sheet E1.23 – Electrical Power Plan – Building 2 Level 3 dated May 20,

2016 and replace with attached sheet E1.23 dated June 2, 2016.

8. Delete Sheet E1.24 – Electrical Power Plan – Building 2 Level 4 dated May 20,

2016 and replace with attached sheet E1.24 dated June 2, 2016.

9. Delete Sheet E4.00 – Electrical Enlarged Plans dated May 20, 2016 and replace

with attached sheet E4.00 dated June 2, 2016.

DRAWINGS PHASE II

1. Delete Sheet A0.00 COVER SHEET dated May 20, 2016 and replace with

attached sheet A0.00 dated June 2, 2016

2. Delete Sheet A3.11 MATERIAL SCHEDULE dated May 20, 2016 and replace

with attached sheet A3.11 dated June 2, 2016

3. Delete Sheet A3.20 DOOR SCHEDULE dated May 20, 2016 and replace with

attached sheet A3.20 dated June 2, 2016

4. Delete Sheet A9.10 ENLARGED FINISH PLAN dated May 20, 2016 and

replace with attached sheet A9.10 dated June 2, 2016

Addendum No. 3

1500 McGowen St. Ste 200

Houston, Texas 77004

Phone: (713) 524-4202 Fax: (713) 524-4071

Page 3 of 3

5. Delete Sheet L3.00 FURNISHING PLAN dated May 20, 2016 and replace

with attached sheet L3.00 dated June 2, 2016.

6. Delete Sheet E1.31 – Electrical Power Plan – Building 3 Level 1 dated May 20,

2016 and replace with attached sheet E1.31 dated June 2, 2016.

7. Delete Sheet E1.32 – Electrical Power Plan – Building 3 Level 2 dated May 20,

2016 and replace with attached sheet E1.32 dated June 2, 2016.

8. Delete Sheet E1.33 – Electrical Power Plan – Building 3 Level 3 dated May 20,

2016 and replace with attached sheet E1.33 dated June 2, 2016.

9. Delete Sheet E1.34 – Electrical Power Plan – Building 3 Level 4 dated May 20,

2016 and replace with attached sheet E1.34 dated June 2, 2016.

10. Delete Sheet E1.35 – Electrical Power Plan – Building 3 Level 5 dated May 20,

2016 and replace with attached sheet E1.35 dated June 2, 2016.

11. Delete Sheet E3.00 – Electrical Enlarged Plans dated May 20, 2016 and replace

with attached sheet E3.00 dated June 2, 2016.

END OF ADDENDUM NO. 3

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 1

SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Provisions established in the “Uniform General Conditions for Construction Contracts”, Construction Agreement be-tween Owner and Contractor, Division 1 – General Requirements, and the Drawings are collectively applicable to this Section.

B. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

1.2 SUMMARY

A. Section Includes:

1. Fire-alarm control unit.

2. Manual fire-alarm boxes.

3. System smoke detectors.

4. Air-sampling smoke detectors.

5. System heat detectors.

6. Notification appliances.

7. Intelligent 520-Hz Audible (Sounder) Bases.

8. Device guards.

9. Firefighters' two-way telephone communication service.

10.9. Magnetic door holders.

11.10. Remote annunciator.

12.11. Graphic annunciator.

13.12. Addressable interface device.

14.13. Digital alarm communicator transmitter.

15.14. Network communications.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 2

16. System printer.

1.3 DEFINITIONS

A. EMT: Electrical Metallic Tubing.

B. FACP: Fire Alarm Control Panel.

C. HLI: High Level Interface.

D. NICET: National Institute for Certification in Engineering Technologies.

E. PC: Personal computer.

1.4 ACTION SUBMITTALS

A. Product Data: For each type of product, including furnished options and accessories.

1. Include construction details, material descriptions, dimensions, profiles, and finishes.

2. Include rated capacities, operating characteristics, and electrical characteristics.

B. Shop Drawings: For fire-alarm system.

1. Comply with recommendations and requirements in the "Documentation" section of the "Fundamentals" chapter in NFPA 72.

2. Include plans, elevations, sections, details, and attachments to other work.

3. Include details of equipment assemblies. Indicate dimensions, weights, loads, required clearances, method of field assembly, components, and locations. Indicate conductor sizes, indicate termination locations and requirements, and distinguish between factory and field wiring.

4. Detail assembly and support requirements.

5. Include voltage drop calculations for notification-appliance circuits.

6. Include battery-size calculations.

7. Include input/output matrix.

8. Include statement from manufacturer that all equipment and components have been tested as a system and meet all requirements in this Specification and in NFPA 72.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 3

9. Include performance parameters and installation details for each detector.

10. Verify that each duct detector is listed for complete range of air velocity, temperature, and humidity possible when air-handling system is operating.

11. Provide program report showing that air-sampling detector pipe layout balances pneumatically within the airflow range of the air-sampling detector.

12. Include plans, sections, and elevations of heating, ventilating, and air-conditioning ducts, drawn to scale; coordinate location of duct smoke detectors and access to them.

a. Show critical dimensions that relate to placement and support of sampling tubes, detector housing, and remote status and alarm indicators.

b. Show field wiring required for HVAC unit shutdown on alarm. c. Show field wiring and equipment required for HVAC unit shutdown on

alarm and override by firefighters' control system. d. Show field wiring and equipment required for HVAC unit shutdown on

alarm and override by firefighters' smoke-evacuation system. e. Locate detectors according to manufacturer's written recommendations. f. Show air-sampling detector pipe routing.

13. Include voice/alarm signaling-service equipment rack or console layout, grounding schematic, amplifier power calculation, and single-line connection diagram.

14. Include floor plans to indicate final outlet locations showing address of each addressable device. Show size and route of cable and conduits and point-to-point wiring diagrams.

C. General Submittal Requirements:

1. Submittals shall be approved by authorities having jurisdiction prior to submitting them to Architect.

2. Shop Drawings shall be prepared by persons with the following qualifications:

a. Trained and certified by manufacturer in fire-alarm system design. b. NICET-certified, fire-alarm technician; Level IV minimum. c. Licensed or certified by authorities having jurisdiction.

D. Delegated-Design Submittal: For notification appliances and smoke and heat detectors, in addition to submittals listed above, indicate compliance with performance requirements and design criteria, including analysis data signed and sealed by the qualified professional engineer responsible for their preparation.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 4

1. Drawings showing the location of each notification appliance and smoke and heat detector, ratings of each, and installation details as needed to comply with listing conditions of the device.

2. Design Calculations: Calculate requirements for selecting the spacing and sensitivity of detection, complying with NFPA 72. Calculate spacing and intensities for strobe signals and sound-pressure levels for audible appliances.

3. Indicate audible appliances required to produce square wave signal per NFPA 72.

1.5 INFORMATIONAL SUBMITTALS

A. Qualification Data: For Installer.

B. Seismic Qualification Certificates: For fire-alarm control unit, accessories, and components, from manufacturer.

1. Basis for Certification: Indicate whether withstand certification is based on actual test of assembled components or on calculation.

2. Dimensioned Outline Drawings of Equipment Unit: Identify center of gravity and locate and describe mounting and anchorage provisions.

3. Detailed description of equipment anchorage devices on which the certification is based and their installation requirements.

C. Field quality-control reports.

1.6 Sample Warranty: For special warranty.

1.7 CLOSEOUT SUBMITTALS

A. Operation and Maintenance Data: For fire-alarm systems and components to include in emergency, operation, and maintenance manuals.

1. In addition to items specified in Section 017823 "Operation and Maintenance Data," include the following and deliver copies to authorities having jurisdiction:

a. Comply with the "Records" section of the "Inspection, Testing and Maintenance" chapter in NFPA 72.

b. Provide "Fire Alarm and Emergency Communications System Record of Completion Documents" according to the "Completion Documents" Article in the "Documentation" section of the "Fundamentals" chapter in NFPA 72.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 5

c. Complete wiring diagrams showing connections between all devices and equipment. Each conductor shall be numbered at every junction point with indication of origination and termination points.

d. Riser diagram. e. Device addresses. f. Air-sampling system sample port locations and modeling program report

showing layout meets performance criteria. g. Record copy of site-specific software. h. Provide "Inspection and Testing Form" according to the "Inspection,

Testing and Maintenance" chapter in NFPA 72, and include the following:

1) Equipment tested. 2) Frequency of testing of installed components. 3) Frequency of inspection of installed components. 4) Requirements and recommendations related to results of maintenance. 5) Manufacturer's user training manuals.

i. Manufacturer's required maintenance related to system warranty requirements.

j. Abbreviated operating instructions for mounting at fire-alarm control unit and each annunciator unit.

B. Software and Firmware Operational Documentation:

1. Software operating and upgrade manuals.

2. Program Software Backup: On magnetic media or compact disk, complete with data files.

3. Device address list.

4. Printout of software application and graphic screens.

1.8 MAINTENANCE MATERIAL SUBMITTALS

A. Furnish extra materials that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.

1. Lamps for Remote Indicating Lamp Units: Quantity equal to 5 percent of amount installed.

2. Lamps for Strobe Units: Quantity equal to 5 percent of amount installed.

3. Smoke Detectors, Fire Detectors: Quantity equal to 5 percent of amount of each type installed.

4. Detector Bases: Quantity equal to 2 percent of amount of each type installed.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 6

5. Keys and Tools: One extra set for access to locked or tamperproofed components.

6. Audible and Visual Notification Appliances: 10 of each type installed.

7. Speaker Strobes: 10 of each type installed.

8. Fuses: 2 of each type installed in the system. Provide in a box or cabinet with compartments marked with fuse types and sizes.

9. Filters for Air-Sampling Detectors: Quantity equal to 2 percent of amount of each type installed, but no less than one unit of each type.

10. Air-Sampling Fan: Quantity equal to 1 for every five detectors, but no less than one unit of each type.

1.9 QUALITY ASSURANCE

A. Installer Qualifications: Personnel shall be trained and certified by manufacturer for installation of units required for this Project.

B. Installer Qualifications: Installation shall be by personnel certified by NICET as fire-alarm Level IV technician.

C. NFPA Certification: Obtain certification according to NFPA 72 by an NRTL (nationally recognized testing laboratory).

D. NFPA Certification: Obtain certification according to NFPA 72 by a UL-listed alarm company.

E. NFPA Certification: Obtain certification according to NFPA 72 in the form of a placard by an FM Global-approved alarm company.

1.10 WARRANTY

A. Special Warranty: Manufacturer agrees to repair or replace fire-alarm system equipment and components that fail in materials or workmanship within specified warranty period.

1. Warranty Extent: All equipment and components not covered in the Maintenance Service Agreement.

2. Warranty Period: 5 1 years from date of Substantial Completion.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 7

PART 2 - PRODUCTS

2.1 SYSTEM DESCRIPTION

A. Source Limitations for Fire-Alarm System and Components: Components shall be compatible with, and operate as an extension of, existing system. Provide system manufacturer's certification that all components provided have been tested as, and will operate as, a system.

B. Noncoded, UL-certified and FM Global-placarded addressable system, with multiplexed signal transmission and voice strobe evacuation.

C. Automatic sensitivity control of certain smoke detectors.

D. All components provided shall be listed for use with the selected system.

E. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application.

F. The new fire alarm control panel at each apartment building shall be equipped with voice notification and have public address capabilities. Each fire alarm control panel shall be interfaced with the campus central monitoring station (campus Proprietary Supervising Station) via a dedicated fiber optics network.

2.2 SYSTEMS OPERATIONAL DESCRIPTION

A. Fire-alarm signal initiation shall be by one or more of the following devices and systems:

1. Manual stations.

2. Heat detectors.

3. Flame detectors.

4. Smoke detectors.

5. Duct smoke detectors.

6. Automatic sprinkler system water flow.

7. Preaction system.

8. Fire-extinguishing system operation.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 8

9. Fire standpipe system.

10. Dry system pressure flow switch.

11. Fire pump running.

B. Fire-alarm signal shall initiate the following actions:

1. Continuously operate alarm notification appliances, including voice evacuation notices.

2. Identify alarm and specific initiating device at fire-alarm control unit, connected network control panels, and remote annunciators.

3. Transmit an alarm signal to the remote alarm receiving station.

4. Unlock electric door locks in designated egress paths.

5. Release fire and smoke doors held open by magnetic door holders.

6. Activate voice/alarm communication system.

7.6. Switch heating, ventilating, and air-conditioning equipment controls to fire-alarm mode.

8.7. Close smoke dampers in air ducts of designated air-conditioning duct systems.

9.8. Activate preaction system.

10.9. Recall elevators to primary or alternate recall floors.

11.10. Activate elevator power shunt trip.

12.11. Activate emergency lighting control.

13.12. Activate emergency shutoffs for gas and fuel supplies.

14.13. Record events in the system memory.

15. Record events by the system printer.

16.14. Indicate device in alarm on the graphic annunciator.

C. Supervisory signal initiation shall be by one or more of the following devices and actions:

1. Valve supervisory switch.

2. High- or low-air-pressure switch of a dry-pipe or preaction sprinkler system.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 9

3. Alert and Action signals of air-sampling detector system.

4. Elevator shunt-trip supervision.

5. Fire pump running.

6. Fire-pump loss of power.

7. Fire-pump power phase reversal.

8. Independent fire-detection and -suppression systems.

9. User disabling of zones or individual devices.

10. Loss of communication with any panel on the network.

D. System trouble signal initiation shall be by one or more of the following devices and actions:

1. Open circuits, shorts, and grounds in designated circuits.

2. Opening, tampering with, or removing alarm-initiating and supervisory signal-initiating devices.

3. Loss of communication with any addressable sensor, input module, relay, control module, remote annunciator, printer interface, or Ethernet module.

4. Loss of primary power at fire-alarm control unit.

5. Ground or a single break in internal circuits of fire-alarm control unit.

6. Abnormal ac voltage at fire-alarm control unit.

7. Break in standby battery circuitry.

8. Failure of battery charging.

9. Abnormal position of any switch at fire-alarm control unit or annunciator.

10. Voice signal amplifier failure.

11. Hose cabinet door open.

E. System Supervisory Signal Actions:

1. Initiate notification appliances.

2. Identify specific device initiating the event at fire-alarm control unit, connected network control panels, and remote annunciators.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 10

3. Record the event on system printer.

4.3. After a time delay of 200 seconds, transmit a trouble or supervisory signal to the remote alarm receiving station.

5.4. Transmit system status to building management system.

6.5. Display system status on graphic annunciator.

2.3 FIRE-ALARM CONTROL UNIT

A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

B. Basis-of-Design Product: Subject to compliance with requirements, provide comparable product by one of the following: 1. Siemens Industry, Inc.; Fire Safety Division. – Model XLSV. 2. GE UTC Fire & Security; A United Technologies Company. 3. Notifier by Honeywell. 4. SimplexGrinnell LP.

C. General Requirements for Fire-Alarm Control Unit:

1. Field-programmable, microprocessor-based, modular, power-limited design with electronic modules, complying with UL 864.

a. System software and programs shall be held in nonvolatile flash, electrically erasable, programmable, read-only memory, retaining the information through failure of primary and secondary power supplies.

b. Include a real-time clock for time annotation of events on the event recorder and printer.

c. Provide communication between the FACP and remote circuit interface panels, annunciators, and displays.

d. The FACP shall be listed for connection to a central-station signaling system service.

e. Provide nonvolatile memory for system database, logic, and operating system and event history. The system shall require no manual input to initialize in the event of a complete power down condition. The FACP shall provide a minimum 500-event history log.

2. Addressable Initiation Device Circuits: The FACP shall indicate which communication zones have been silenced and shall provide selective silencing of alarm notification appliance by building communication zone.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 11

3. Addressable Control Circuits for Operation of Notification Appliances and Mechanical Equipment: The FACP shall be listed for releasing service.

D. Alphanumeric Display and System Controls: Arranged for interface between human operator at fire-alarm control unit and addressable system components including annunciation and supervision. Display alarm, supervisory, and component status messages and the programming and control menu.

1. Annunciator and Display: Liquid-crystal type, 80 characters, minimum.

2. Keypad: Arranged to permit entry and execution of programming, display, and control commands.

E. Alphanumeric Display and System Controls: Arranged for interface between human operator at fire-alarm control unit and addressable system components including annunciation and supervision. Display alarm, supervisory, and component status messages and the programming and control menu.

1. Annunciator and Display: Liquid-crystal type, three line(s) of 80 characters, minimum.

2. Keypad: Arranged to permit entry and execution of programming, display, and control commands.

F. Initiating-Device, Notification-Appliance, and Signaling-Line Circuits:

1. Pathway Class Designations: NFPA 72, Class C.

2. Pathway Survivability: Level 1-0.

3. Install no more than 50 addressable devices on each signaling-line circuit. Suggest 80-90% capacity

G. Smoke-Alarm Verification: - Using Fireprint Technology – Application Specific detection – no timed verification.

1. Initiate audible and visible indication of an "alarm-verification" signal at fire-alarm control unit.

2. Activate an approved "alarm-verification" sequence at fire-alarm control unit and detector.

3. Record events by the system printer.

4. Sound general alarm if the alarm is verified.

5. Cancel fire-alarm control unit indication and system reset if the alarm is not verified.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 12

H. Notification-Appliance Circuit:

1. Audible appliances shall sound in a three-pulse temporal pattern, as defined in NFPA 72.

2. Where notification appliances provide signals to sleeping areas, the alarm signal shall be a 520-Hz square wave with an intensity 15 dB above the average ambient sound level or 5 dB above the maximum sound level, or at least 75 dBA, whichever is greater, measured at the pillow. Intelligent 520-Hz audible (sounder) bases shall be Siemens, Model No. ABHW-4S.

3. Visual alarm appliances shall flash in synchronization where multiple appliances are in the same field of view, as defined in NFPA 72.

I. Elevator Recall:

1. Elevator recall shall be initiated only by one of the following alarm-initiating devices:

a. Elevator lobby detectors except the lobby detector on the designated floor. b. Smoke detector in elevator machine room. c. Smoke detectors in elevator hoistway.

2. Elevator controller shall be programmed to move the cars to the alternate recall floor if lobby detectors located on the designated recall floors are activated.

3. Water-flow alarm connected to sprinkler in an elevator shaft and elevator machine room shall shut down elevators associated with the location without time delay.

a. Water-flow switch associated with the sprinkler in the elevator pit may have a delay to allow elevators to move to the designated floor.

J. Door Controls: Door hold-open devices that are controlled by smoke detectors at doors in smoke-barrier walls shall be connected to fire-alarm system.

K.J. Remote Smoke-Detector Sensitivity Adjustment: Controls shall select specific addressable smoke detectors for adjustment, display their current status and sensitivity settings, and change those settings. Allow controls to be used to program repetitive, time-scheduled, and automated changes in sensitivity of specific detector groups. Record sensitivity adjustments and sensitivity-adjustment schedule changes in system memory, and print out the final adjusted values on system printer.

L.K. Transmission to Remote Alarm Receiving Station: Automatically transmit alarm, supervisory, and trouble signals to a remote alarm station.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 13

M.L. Voice/Alarm Signaling Service: Central emergency communication system with redundant microphones, preamplifiers, amplifiers, and tone generators provided in a separate cabinet located in the fire command center.

1. Indicate number of alarm channels for automatic, simultaneous transmission of different announcements to different zones or for manual transmission of announcements by use of the central-control microphone. Amplifiers shall comply with UL 1711.

a. Allow the application of, and evacuation signal to, indicated number of zones and, at the same time, allow voice paging to the other zones selectively or in any combination.

b. Programmable tone and message sequence selection. c. Standard digitally recorded messages for "Evacuation" and "All Clear." d. Generate tones to be sequenced with audio messages of type recommended

by NFPA 72 and that are compatible with tone patterns of notification-appliance circuits of fire-alarm control unit.

2. Status Annunciator: Indicate the status of various voice/alarm speaker zones and the status of firefighters' two-way telephone communication zones.

3.2. Preamplifiers, amplifiers, and tone generators shall automatically transfer to backup units, on primary equipment failure.

N.M. Additional Interface Equipment: Shall be provided in each fire alarm control panel (FACP) for interfacing with the campus FAS network.

1. NIC -C Network Interface Card.

2. RPM Remote Printer Interface (Provides the 485 Network).

3. D2325CPS (single mode module) Fiber Interface Module.

O.N. Interface Wiring Requirements: Shall be provided between each fire alarm control panel (FACP) and the fiber interface cabinet.

1. Provide one (1) 18/2 shielded cable between the FACP and the fiber interface cabinet.

2. Provide one (1) 14/2 cable between the FACP and the fiber module in the fiber interface cabinet.

P. Printout of Events: On receipt of signal, print alarm, supervisory, and trouble events. Identify zone, device, and function. Include type of signal (alarm, supervisory, or trouble) and date and time of occurrence. Differentiate alarm signals from all other printed indications. Also print system reset event, including same information for

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 14

device, location, date, and time. Commands initiate the printing of a list of existing alarm, supervisory, and trouble conditions in the system and a historical log of events.

Q.O. Primary Power: 24-V dc obtained from 120-V ac service and a power-supply module. Initiating devices, notification appliances, signaling lines, trouble signals, supervisory signals shall be powered by 24-V dc source.

1. Alarm current draw of entire fire-alarm system shall not exceed 80 percent of the power-supply module rating.

R.P. Secondary Power: 24-V dc supply system with batteries, automatic battery charger, and automatic transfer switch.

1. Batteries: Sealed lead calcium.

S.Q. Instructions: Computer printout or typewritten instruction card mounted behind a plastic or glass cover in a stainless-steel or aluminum frame. Include interpretation and describe appropriate response for displays and signals. Briefly describe the functional operation of the system under normal, alarm, and trouble conditions.

2.4 MANUAL FIRE-ALARM BOXES

A. General Requirements for Manual Fire-Alarm Boxes: Comply with UL 38. Boxes shall be finished in red with molded, raised-letter operating instructions in contrasting color; shall show visible indication of operation; and shall be mounted on recessed outlet box. If indicated as surface mounted, provide manufacturer's surface back box.

1. Double-action mechanism requiring two actions to initiate an alarm, pull-lever type; with integral addressable module arranged to communicate manual-station status (normal, alarm, or trouble) to fire-alarm control unit.

2. Station Reset: Key- or wrench-operated switch.

3. Indoor Protective Shield: Factory-fabricated, clear plastic enclosure hinged at the top to permit lifting for access to initiate an alarm. Lifting the cover actuates an integral battery-powered audible horn intended to discourage false-alarm operation.

4. Weatherproof Protective Shield: Factory-fabricated, clear plastic enclosure hinged at the top to permit lifting for access to initiate an alarm.

2.5 SYSTEM SMOKE DETECTORS

A. General Requirements for System Smoke Detectors:

1. Comply with UL 268; operating at 24-V dc, nominal.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 15

2. Detectors shall be four-wire type.

3. Integral Addressable Module: Arranged to communicate detector status (normal, alarm, or trouble) to fire-alarm control unit.

4. Base Mounting: Detector and associated electronic components shall be mounted in a twist-lock module that connects to a fixed base. Provide terminals in the fixed base for connection to building wiring.

5. Self-Restoring: Detectors do not require resetting or readjustment after actuation to restore them to normal operation.

6. Integral Visual-Indicating Light: LED type, indicating detector has operated and power-on status.

7. Remote Control: Unless otherwise indicated, detectors shall be digital-addressable type, individually monitored at fire-alarm control unit for calibration, sensitivity, and alarm condition and individually adjustable for sensitivity by fire-alarm control unit.

a. Rate-of-rise temperature characteristic of combination smoke- and heat-detection units shall be selectable at fire-alarm control unit for 15 or 20 deg F (8 or 11 deg C) per minute.

b. Fixed-temperature sensing characteristic of combination smoke- and heat-detection units shall be independent of rate-of-rise sensing and shall be settable at fire-alarm control unit to operate at 135 or 155 deg F (57 or 68 deg C).

c. Multiple levels of detection sensitivity for each sensor. d. Sensitivity levels based on time of day.

B. Photoelectric Smoke Detectors:

1. Detector address shall be accessible from fire-alarm control unit and shall be able to identify the detector's location within the system and its sensitivity setting.

2. An operator at fire-alarm control unit, having the designated access level, shall be able to manually access the following for each detector:

a. Primary status. b. Device type. c. Present average value. d. Present sensitivity selected. e. Sensor range (normal, dirty, etc.).

C. Duct Smoke Detectors: Photoelectric type complying with UL 268A.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 16

1. Detector address shall be accessible from fire-alarm control unit and shall be able to identify the detector's location within the system and its sensitivity setting.

2. An operator at fire-alarm control unit, having the designated access level, shall be able to manually access the following for each detector:

a. Primary status. b. Device type. c. Present average value. d. Present sensitivity selected. e. Sensor range (normal, dirty, etc.).

3. Each sensor shall have multiple levels of detection sensitivity.

4. Sampling Tubes: Design and dimensions as recommended by manufacturer for specific duct size, air velocity, and installation conditions where applied.

5. Relay Fan Shutdown: Fully programmable relay rated to interrupt fan motor-control circuit.

2.6 SYSTEM HEAT DETECTORS

A. General Requirements for Heat Detectors: Comply with UL 521.

1. Temperature sensors shall test for and communicate the sensitivity range of the device.

B. Heat Detector, Combination Type: Actuated by either a fixed temperature of 135 deg F (57 deg C) or a rate of rise that exceeds 15 deg F (8 deg C) per minute unless otherwise indicated.

1. Mounting: Twist-lock base interchangeable with smoke-detector bases.

2. Integral Addressable Module: Arranged to communicate detector status (normal, alarm, or trouble) to fire-alarm control unit.

2.7 NOTIFICATION APPLIANCES

A. General Requirements for Notification Appliances: Individually addressed, connected to a signaling-line circuit, equipped for mounting as indicated, and with screw terminals for system connections.

B. General Requirements for Notification Appliances: Connected to notification-appliance signal circuits, zoned as indicated, equipped for mounting as indicated, and with screw terminals for system connections.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 17

1. Combination Devices: Factory-integrated audible and visible devices in a single-mounting assembly, equipped for mounting as indicated, and with screw terminals for system connections.

C. Chimes, Low-Level Output: Vibrating type, 75-dBA minimum rated output.

D. Chimes, High-Level Output: Vibrating type, 81-dBA minimum rated output.

E. Horns: Electric-vibrating-polarized type, 24-V dc; with provision for housing the operating mechanism behind a grille. Comply with UL 464. Horns shall produce a sound-pressure level of 90 dBA, measured 10 feet from the horn, using the coded signal prescribed in UL 464 test protocol.

F. Visible Notification Appliances: Xenon strobe lights complying with UL 1971, with clear or nominal white polycarbonate lens mounted on an aluminum faceplate. The word "FIRE" is engraved in minimum 1-inch-high letters on the lens.

1. Rated Light Output:

a. 15/30/75/110 cd, selectable in the field.

2. Mounting: Wall mounted unless otherwise indicated.

3. For units with guards to prevent physical damage, light output ratings shall be determined with guards in place.

4. Flashing shall be in a temporal pattern, synchronized with other units.

5. Strobe Leads: Factory connected to screw terminals.

6. Mounting Faceplate: Factory finished, white.

G. Voice/Tone Notification Appliances (Speakers or Combination Speaker Strobes):

1. Comply with UL 1480.

2. Speakers for Voice Notification: Locate speakers for voice notification to provide the intelligibility requirements of the "Notification Appliances" and "Emergency Communications Systems" chapters in NFPA 72.

3. High-Range Units: Rated 2 to 15 W.

4. Low-Range Units: Rated 1 to 2 W.

5. Mounting: Flush.

6. Matching Transformers: Tap range matched to acoustical environment of speaker location.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 18

H. Exit Marking Audible Notification Appliance:

1. Exit marking audible notification appliances shall meet the audibility requirements in NFPA 72.

2. Provide exit marking audible notification appliances at the entrance to all building exits.

3. Provide exit marking audible notification appliances at the entrance to areas of refuge with audible signals distinct from those used for building exit marking.

2.8 MAGNETIC DOOR HOLDERS

A. Description: Units are equipped for wall or floor mounting as indicated and are complete with matching doorplate.

1. Electromagnets: Require no more than 3 W to develop 25-lbf (111-N) holding force.

2. Wall-Mounted Units: Flush mounted unless otherwise indicated.

3. Rating: 24-V ac or dc.

4. Rating: 120-V ac.

B. Material and Finish: Match door hardware.

2.9 REMOTE ANNUNCIATOR

A. Description: Annunciator functions shall match those of fire-alarm control unit for alarm, supervisory, and trouble indications. Manual switching functions shall match those of fire-alarm control unit, including acknowledging, silencing, resetting, and testing.

1. Mounting: Flush cabinet, NEMA 250, Type 1.

B. Display Type and Functional Performance: Alphanumeric display and LED indicating lights shall match those of fire-alarm control unit. Provide controls to acknowledge, silence, reset, and test functions for alarm, supervisory, and trouble signals.

2.10 ADDRESSABLE INTERFACE DEVICE

A. General:

1. Include address-setting means on the module.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 19

2. Store an internal identifying code for control panel use to identify the module type.

3. Listed for controlling HVAC fan motor controllers.

B. Monitor Module: Microelectronic module providing a system address for alarm-initiating devices for wired applications with normally open contacts.

C. Integral Relay: Capable of providing a direct signal to elevator controller to initiate elevator recall and to circuit-breaker shunt trip for power shutdown.

1. Allow the control panel to switch the relay contacts on command.

2. Have a minimum of two normally open and two normally closed contacts available for field wiring.

D. Control Module:

1. Operate notification devices.

2. Operate solenoids for use in sprinkler service.

2.11 NETWORK COMMUNICATIONS

A. Provide network communications for fire-alarm system according to fire-alarm manufacturer's written requirements.

B. Provide network communications pathway per manufacturer's written requirements and requirements in NFPA 72 and NFPA 70.

C. Provide integration gateway using BACnet for connection to building automation system.

2.12 SYSTEM PRINTER

A. Printer shall be listed and labeled as an integral part of fire-alarm system.

2.132.12 DEVICE GUARDS

A. Description: Welded wire mesh of size and shape for the manual station, smoke detector, gong, or other device requiring protection.

1. Factory fabricated and furnished by device manufacturer.

2. Finish: Paint of color to match the protected device.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 20

2.142.13 FIRE ALARM WIRE AND CABLE

A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

B. Basis-of-Design Product: Subject to compliance with requirements, provide comparable product by one of the following:

1. Comtran Corporation. 2. Draka Cableteq USA. 3. Genesis Cable Products; Honeywell International, Inc. 4. Rockbestos-Suprenant Cable Corp. 5. West Penn Wire.

C. General Wire and Cable Requirements: NRTL listed and labeled as complying with NFPA 70, Article 760.

D. Signaling Line Circuits: Twisted, shielded pair, not less than No. 18 AWG.

1. Circuit Integrity Cable: Twisted shielded pair, NFPA 70, Article 760, Classification CI, for power-limited fire alarm signal service. Type FPL. NRTL listed and labeled as complying with UL 1424 and UL 2196 for a 2-hour rating.

E. Non-Power-Limited Circuits: Solid-copper conductors with 600-V rated, 75 degree C., color-coded insulation.

1. Low-Voltage Circuits: No. 16 AWG, minimum. 2. Line-Voltage Circuits: No. 12 AWG, minimum. 3. Multi-conductor Armored Cable: NFPA 70, Type MC, copper conductors,

Type TFN/THHN conductor insulation, copper drain wire, copper armor with red identifier stripe, NTRL listed for fire alarm and cable tray installation, plenum rated, and complying with requirements in UL 2196 for a 2-hour rating.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine areas and conditions for compliance with requirements for ventilation, temperature, humidity, and other conditions affecting performance of the Work.

1. Verify that manufacturer's written instructions for environmental conditions have been permanently established in spaces where equipment and wiring are installed, before installation begins.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 21

B. Examine roughing-in for electrical connections to verify actual locations of connections before installation.

C. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 EQUIPMENT INSTALLATION

A. Comply with NFPA 72, NFPA 101, and requirements of authorities having jurisdiction for installation and testing of fire-alarm equipment. Install all electrical wiring to comply with requirements in NFPA 70 including, but not limited to, Article 760, "Fire Alarm Systems."

1. Devices placed in service before all other trades have completed cleanup shall be replaced.

2. Devices installed but not yet placed in service shall be protected from construction dust, debris, dirt, moisture, and damage according to manufacturer's written storage instructions.

B. Install wall-mounted equipment, with tops of cabinets not more than 78 inches (1980 mm) above the finished floor.

C. Manual Fire-Alarm Boxes:

1. Install manual fire-alarm box in the normal path of egress within 60 inches of the exit doorway.

2. Mount manual fire-alarm box on a background of a contrasting color.

3. The operable part of manual fire-alarm box shall be between 42 inches and 48 inches above floor level. All devices shall be mounted at the same height unless otherwise indicated.

D. Smoke- or Heat-Detector Spacing:

1. Comply with the "Smoke-Sensing Fire Detectors" section in the "Initiating Devices" chapter in NFPA 72, for smoke-detector spacing.

2. Comply with the "Heat-Sensing Fire Detectors" section in the "Initiating Devices" chapter in NFPA 72, for heat-detector spacing.

3. Smooth ceiling spacing shall not exceed 30 feet.

4. Spacing of detectors for irregular areas, for irregular ceiling construction, and for high ceiling areas shall be determined according to Annex A or Annex B in NFPA 72.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 22

5. HVAC: Locate detectors not closer than 36 inches from air-supply diffuser or return-air opening.

6. Lighting Fixtures: Locate detectors not closer than 12 inches from any part of a lighting fixture and not directly above pendant mounted or indirect lighting.

E. Install a cover on each smoke detector that is not placed in service during construction. Cover shall remain in place except during system testing. Remove cover prior to system turnover.

F. Duct Smoke Detectors: Comply with NFPA 72 and NFPA 90A. Install sampling tubes so they extend the full width of duct. Tubes more than 36 inches long shall be supported at both ends.

1. Do not install smoke detector in duct smoke-detector housing during construction. Install detector only during system testing and prior to system turnover.

G. Air-Sampling Smoke Detectors: If using multiple pipe runs, the runs shall be pneumatically balanced.

H. Elevator Shafts: Coordinate temperature rating and location with sprinkler rating and location.

I. Remote Status and Alarm Indicators: Install in a visible location near each smoke detector, sprinkler water-flow switch, and valve-tamper switch that is not readily visible from normal viewing position.

J. Audible Alarm-Indicating Devices: Install not less than 6 inches below the ceiling. Install bells and horns on flush-mounted back boxes with the device-operating mechanism concealed behind a grille. Install all devices at the same height unless otherwise indicated.

K. Visible Alarm-Indicating Devices: Install adjacent to each alarm bell or alarm horn and at least 6 inches below the ceiling. Install all devices at the same height unless otherwise indicated.

L. Device Location-Indicating Lights: Locate in public space near the device they monitor.

3.3 PATHWAYS

A. Pathways above lay-in ceilings may be routed exposed.

1. Exposed pathways located less than 96 inches above the floor shall be installed in EMT.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 23

2. Pathways above non-accessible ceilings shall be installed in EMT.

B. Exposed EMT shall be painted red enamel.

3.4 CONNECTIONS

A. For fire-protection systems related to doors in fire-rated walls and partitions and to doors in smoke partitions, comply with requirements in Section 087100 "Door Hardware." Connect hardware and devices to fire-alarm system.

1. Verify that hardware and devices are listed for use with installed fire-alarm system before making connections.

B. Make addressable connections with a supervised interface device to the following devices and systems. Install the interface device less than 36 inches from the device controlled. Make an addressable confirmation connection when such feedback is available at the device or system being controlled.

1. Smoke dampers in air ducts of designated HVAC duct systems.

2. Magnetically held-open doors.

3. Electronically locked doors and access gates.

4. Alarm-initiating connection to elevator recall system and components.

5. Alarm-initiating connection to activate emergency lighting control.

6. Supervisory connections at valve supervisory switches.

7. Supervisory connections at low-air-pressure switch of each dry-pipe sprinkler system.

8. Supervisory connections at elevator shunt-trip breaker.

9. Data communication circuits for connection to building management system.

10. Supervisory connections at fire-extinguisher locations.

11. Supervisory connections at fire-pump power failure including a dead-phase or phase-reversal condition.

12. Supervisory connections at fire-pump engine control panel.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 24

3.5 IDENTIFICATION

A. Identify system components, wiring, cabling, and terminals. Comply with requirements for identification specified in Section 260553 "Identification for Electrical Systems."

B. Install framed instructions in a location visible from fire-alarm control unit.

3.6 GROUNDING

A. Ground fire-alarm control unit and associated circuits; comply with IEEE 1100. Install a ground wire from main service ground to fire-alarm control unit.

B. Ground shielded cables at the control panel location only. Insulate shield at device location.

3.7 FIELD QUALITY CONTROL

A. Field tests shall be witnessed by authorities having jurisdiction.

B. Manufacturer's Field Service: Engage a factory-authorized service representative to test and inspect components, assemblies, and equipment installations, including connections.

C. Perform fire alarm system acceptance testing and inspections per Texas A&M University “Annex C” checklist.

D. Perform the following tests and inspections with the assistance of a factory-authorized service representative:

1. Visual Inspection: Conduct visual inspection prior to testing.

a. Inspection shall be based on completed record Drawings and system documentation that is required by the "Completion Documents, Preparation" table in the "Documentation" section of the "Fundamentals" chapter in NFPA 72.

b. Comply with the "Visual Inspection Frequencies" table in the "Inspection" section of the "Inspection, Testing and Maintenance" chapter in NFPA 72; retain the "Initial/Reacceptance" column and list only the installed components.

2. System Testing: Comply with the "Test Methods" table in the "Testing" section of the "Inspection, Testing and Maintenance" chapter in NFPA 72.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 25

3. Test audible appliances for the public operating mode according to manufacturer's written instructions. Perform the test using a portable sound-level meter complying with Type 2 requirements in ANSI S1.4.

4. Test audible appliances for the private operating mode according to manufacturer's written instructions.

5. Test visible appliances for the public operating mode according to manufacturer's written instructions.

6. Factory-authorized service representative shall prepare the "Fire Alarm System Record of Completion" in the "Documentation" section of the "Fundamentals" chapter in NFPA 72 and the "Inspection and Testing Form" in the "Records" section of the "Inspection, Testing and Maintenance" chapter in NFPA 72.

E. Reacceptance Testing: Perform reacceptance testing to verify the proper operation of added or replaced devices and appliances.

F. Fire-alarm system will be considered defective if it does not pass tests and inspections.

G. Prepare test and inspection reports.

H. Maintenance Test and Inspection: Perform tests and inspections listed for weekly, monthly, quarterly, and semiannual periods. Use forms developed for initial tests and inspections.

I. Annual Test and Inspection: One year after date of Substantial Completion, test fire-alarm system complying with visual and testing inspection requirements in NFPA 72. Use forms developed for initial tests and inspections.

3.8 MAINTENANCE SERVICE

A. Initial Maintenance Service: Beginning at Substantial Completion, maintenance service shall include 12 months' full maintenance by skilled employees of manufacturer's designated service organization. Include preventive maintenance, repair or replacement of worn or defective components, lubrication, cleaning, and adjusting as required for proper operation. Parts and supplies shall be manufacturer's authorized replacement parts and supplies.

1. Include visual inspections according to the "Visual Inspection Frequencies" table in the "Testing" paragraph of the "Inspection, Testing and Maintenance" chapter in NFPA 72.

2. Perform tests in the "Test Methods" table in the "Testing" paragraph of the "Inspection, Testing and Maintenance" chapter in NFPA 72.

Fenix Estates Apartments Phase I and II May 20, 2016 June 2, 2016 Harris County Housing Authority Addendum #3

DIGITAL ADDRESSABLE FIRE-ALARM SYSTEM 283111 - 26

3. Perform tests per the "Testing Frequencies" table in the "Testing" paragraph of the "Inspection, Testing and Maintenance" chapter in NFPA 72.

3.9 SOFTWARE SERVICE AGREEMENT

A. Comply with UL 864.

B. Technical Support: Beginning at Substantial Completion, service agreement shall include software support for two years.

C. Upgrade Service: At Substantial Completion, update software to latest version. Install and program software upgrades that become available within two years from date of Substantial Completion. Upgrading software shall include operating system and new or revised licenses for using software.

1. Upgrade Notice: At least 60 days to allow Owner to schedule access to system and to upgrade computer equipment if necessary.

3.10 DEMONSTRATION

A. Engage a factory-authorized service representative to train Owner's maintenance personnel to adjust, operate, and maintain fire alarm control system.

END OF SECTION 283111

O

6

AST

1T E

T E

SREGI

CENERR

T

RED

F T4 3 6

E XAS

CH

IM

S.D

HT

IT ECT

RA

E

OwnerHARRIS COUNTY HOUSING AUTHORITY8933 INTERCHANGE, HOUSTON, TX 77054P. 713.669.4514

Structural EngineersMISSION ENGINEERING, INC.102060 WESTHEIMER ROAD #585, HOUSTON, TX 77042P. 713.961.0018

ArchitectSMITH & COMPANY ARCHITECTS, INC.1500 MCGOWEN STREET #200, HOUSTON, TX 77004P. 713.524.4202 F. 713.524.4071

MEP/FP EngineersTTG CORP.13105 N.W. FREEWAY #690, HOUSTON, TX 77040P. 713.896.6990

Civil EngineersTRW ENGINEERING3300 S. GESSNER ROAD #100, HOUSTON, TX 77063P. 713.784.7777

Information/TechnologyConsultantDATACOM DESIGN GROUP8100 WASHINGTON AVENUE #260, HOUSTON, TX 77007P. 713.589.9797

HARRIS COUNTY PUBLIC INFRASTRUCTURE DEPARTMENTARCHITECTURE / ENGINEERING DIVISION

Landscape ArchitectKNUDSON LP8588 KATY FREEWAY #441, HOUSTON, TX 77024P. 713.463.8200

HOUSTON, TEXASS&C PROJECT NO.032415N

MAY 20, 2016

GENE LOCKECOMMISSIONER PRECINCT 1

JACK NORMANCOMMISSIONER PRECINCT 2

BARBARA J. SCHOTTCOUNTY AUDITOR

STEVE RADACKCOMMISSIONER PRECINCT 3

R. JACK CAGLECOMMISSIONER PRECINCT 4

JOHN R. BLOUNT, P.E.COUNTY ENGINEER

ED EMMETTCOUNTY JUDGE

JOE ELLISVICE CHAIR

ROBERTO GONZALEZCOMMISSIONER

JOE VILLARREALCOMMISSIONER

GERALD WOMACKCOMMISSIONER

KERRY WRIGHTCHAIR

TOM MCCASLANDSECRETARY

HCHA BOARD OF DIRECTORS HARRIS COUNTY COMMISSIONERS COURT

ISSUED FOR BID

1

1ST ROUND - CITY OF

HOUSTON REVIEW CHANGES

1 9.23.2015

2nd ROUND - CITY OF

HOUSTON REVIEW CHANGES

211.06.2015

DATE ISSUED:

REVISIONS:

PROJECT NUMBER:

032415N

MAY 20, 2016

NO. DATE DESCRIPTION

JUNE 2, 2016

HOUSTON, TEXAS 77004

1500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202

FAX: 713-524-4071

www.sc-arch.com

FEN

IX E

STAT

ESBU

ILD

ING

S 1

& 2

- PH

ASE

IH

OUS

TON

, TEX

AS

4630 N Loop 1604 West, Suite 201

San Antonio, Texas 78249

210.530.7000 F:210.377.1575

TBPE Firm Registration: F-903

ADDENDUM #3

306.02.2016

N

1/8" = 1'-0" 1ELECTRICAL POWER PLAN - BUILDING 1 - LEVEL 2 E1.12

ELEC

TRIC

ALPO

WER

PLA

NBU

ILD

ING

1 L

EVEL

2

1 B.R.

302-B1

STAIR A

301-B1

1 B.R.

303-B1

EFF-1

304-B1

CO

RR

ID

OR

30

0-B

1

EFF-1

305-B1

KITCHEN

306-B1

STORAGE

307-B1

ELECT.

313-B1

ELEVATOR

VESTIBULE

311-B1

1 B.R.

312-B1

EFF-1

314-B1

EFF-2

316-B1

EFF-1

318-B1

1 B.R.

320-B1

ELECT.

322-B1

TV LOUNGE

326-B1

ST

AIR

B

32

7-B

1

TRASH

325-B1

1 B.R.

323-B1

EFF-1

321-B1

EFF-2

319-B1

EFF-1

317-B1

LAUNDRY

315-B1

LIVING ROOM

308-B1

CORRIDOR

324-B1

ELEV

145

1 B.R.

301-B2

STAIR B

302-B2

TRASH

304-B2

EFF-1

303-B2

1 B.R.

306-B2

CO

RR

ID

OR

30

0-B

2

1ST ROUND - CITY OF

HOUSTON REVIEW CHANGES

1 9.23.2015

2nd ROUND - CITY OF

HOUSTON REVIEW CHANGES

211.06.2015

DATE ISSUED:

REVISIONS:

PROJECT NUMBER:

032415N

MAY 20, 2016

NO. DATE DESCRIPTION

JUNE 2, 2016

HOUSTON, TEXAS 77004

1500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202

FAX: 713-524-4071

www.sc-arch.com

FEN

IX E

STAT

ESBU

ILD

ING

S 1

& 2

- PH

ASE

IH

OUS

TON

, TEX

AS

4630 N Loop 1604 West, Suite 201

San Antonio, Texas 78249

210.530.7000 F:210.377.1575

TBPE Firm Registration: F-903

ADDENDUM #3

306.02.2016

N

1/8" = 1'-0" 1ELECTRICAL POWER PLAN - BUILDING 1 - LEVEL 3 E1.13

ELEC

TRIC

ALPO

WER

PLA

NBU

ILD

ING

1 L

EVEL

3

1 B.R.

402-B1

STAIR A

401-B1

EFF-1

404-B1

1 B.R.

403-B1

EFF-1

405-B1

STORAGE

409-B1

IDF ROOM

407-B1

1 B.R.

412-B1

EFF-2

406-B1

EFF-1

408-B1

1 B.R.

410-B1

EFF-1

414-B1

EFF-2

416-B1

EFF-1

418-B1

1 B.R.

420-B1

ELECT.

422-B1

TV LOUNGE

426-B1

STAIR B

427-B1

TRASH

425-B1

1 B.R.

423-B1

EFF-1

421-B1

EFF-2

419-B1

EFF-1

417-B1

LAUNDRY

415-B1

ELECT.

413-B1

ELEVATOR

VESTIBULE

411-B1

CO

RR

ID

OR

40

0-B

1

ELEV

145

1 B.R.

401-B2

STAIR B

402-B2

TRASH

404-B2

EFF-1

403-B2

1 B.R.

406-B2

CO

RR

ID

OR

40

0-B

2

1ST ROUND - CITY OF

HOUSTON REVIEW CHANGES

1 9.23.2015

2nd ROUND - CITY OF

HOUSTON REVIEW CHANGES

211.06.2015

DATE ISSUED:

REVISIONS:

PROJECT NUMBER:

032415N

MAY 20, 2016

NO. DATE DESCRIPTION

JUNE 2, 2016

HOUSTON, TEXAS 77004

1500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202

FAX: 713-524-4071

www.sc-arch.com

FEN

IX E

STAT

ESBU

ILD

ING

S 1

& 2

- PH

ASE

IH

OUS

TON

, TEX

AS

4630 N Loop 1604 West, Suite 201

San Antonio, Texas 78249

210.530.7000 F:210.377.1575

TBPE Firm Registration: F-903

ADDENDUM #3

306.02.2016

N

1/8" = 1'-0" 1ELECTRICAL POWER PLAN - BUILDING 1 - LEVEL 4 E1.14

ELEC

TRIC

ALPO

WER

PLA

NBU

ILD

ING

1 L

EVEL

4

1ST ROUND - CITY OF

HOUSTON REVIEW CHANGES

1 9.23.2015

2nd ROUND - CITY OF

HOUSTON REVIEW CHANGES

211.06.2015

DATE ISSUED:

REVISIONS:

PROJECT NUMBER:

032415N

MAY 20, 2016

NO. DATE DESCRIPTION

JUNE 2, 2016

HOUSTON, TEXAS 77004

1500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202

FAX: 713-524-4071

www.sc-arch.com

FEN

IX E

STAT

ESBU

ILD

ING

S 1

& 2

- PH

ASE

IH

OUS

TON

, TEX

AS

4630 N Loop 1604 West, Suite 201

San Antonio, Texas 78249

210.530.7000 F:210.377.1575

TBPE Firm Registration: F-903

ADDENDUM #3

306.02.2016

N

1/8" = 1'-0" 1ELECTRICAL POWER PLAN - BUILDING 2 - LEVEL 1 E1.21

ELEC

TRIC

ALPO

WER

PLA

NBU

ILD

ING

2 L

EVEL

1

1ST ROUND - CITY OF

HOUSTON REVIEW CHANGES

1 9.23.2015

2nd ROUND - CITY OF

HOUSTON REVIEW CHANGES

211.06.2015

DATE ISSUED:

REVISIONS:

PROJECT NUMBER:

032415N

MAY 20, 2016

NO. DATE DESCRIPTION

JUNE 2, 2016

HOUSTON, TEXAS 77004

1500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202

FAX: 713-524-4071

www.sc-arch.com

FEN

IX E

STAT

ESBU

ILD

ING

S 1

& 2

- PH

ASE

IH

OUS

TON

, TEX

AS

4630 N Loop 1604 West, Suite 201

San Antonio, Texas 78249

210.530.7000 F:210.377.1575

TBPE Firm Registration: F-903

ADDENDUM #3

306.02.2016

N

1/8" = 1'-0" 1ELECTRICAL POWER PLAN - BUILDING 2 - LEVEL 2 E1.22

ELEC

TRIC

ALPO

WER

PLA

NBU

ILD

ING

2 L

EVEL

2

1ST ROUND - CITY OF

HOUSTON REVIEW CHANGES

1 9.23.2015

2nd ROUND - CITY OF

HOUSTON REVIEW CHANGES

211.06.2015

DATE ISSUED:

REVISIONS:

PROJECT NUMBER:

032415N

MAY 20, 2016

NO. DATE DESCRIPTION

JUNE 2, 2016

HOUSTON, TEXAS 77004

1500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202

FAX: 713-524-4071

www.sc-arch.com

FEN

IX E

STAT

ESBU

ILD

ING

S 1

& 2

- PH

ASE

IH

OUS

TON

, TEX

AS

4630 N Loop 1604 West, Suite 201

San Antonio, Texas 78249

210.530.7000 F:210.377.1575

TBPE Firm Registration: F-903

ADDENDUM #3

306.02.2016

N

1/8" = 1'-0" 1ELECTRICAL POWER PLAN - BUILDING 2 - LEVEL 3 E1.23

ELEC

TRIC

ALPO

WER

PLA

NBU

ILD

ING

2 L

EVEL

3

1ST ROUND - CITY OF

HOUSTON REVIEW CHANGES

1 9.23.2015

2nd ROUND - CITY OF

HOUSTON REVIEW CHANGES

211.06.2015

DATE ISSUED:

REVISIONS:

PROJECT NUMBER:

032415N

MAY 20, 2016

NO. DATE DESCRIPTION

JUNE 2, 2016

HOUSTON, TEXAS 77004

1500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202

FAX: 713-524-4071

www.sc-arch.com

FEN

IX E

STAT

ESBU

ILD

ING

S 1

& 2

- PH

ASE

IH

OUS

TON

, TEX

AS

4630 N Loop 1604 West, Suite 201

San Antonio, Texas 78249

210.530.7000 F:210.377.1575

TBPE Firm Registration: F-903

ADDENDUM #3

306.02.2016

N

1/8" = 1'-0" 1ELECTRICAL POWER PLAN - BUILDING 2 - LEVEL 4 E1.24

ELEC

TRIC

ALPO

WER

PLA

NBU

ILD

ING

2 L

EVEL

4

1ST ROUND - CITY OF

HOUSTON REVIEW CHANGES

1 9.23.2015

2nd ROUND - CITY OF

HOUSTON REVIEW CHANGES

211.06.2015

DATE ISSUED:

REVISIONS:

PROJECT NUMBER:

032415N

MAY 20, 2016

NO. DATE DESCRIPTION

JUNE 2, 2016

HOUSTON, TEXAS 77004

1500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202

FAX: 713-524-4071

www.sc-arch.com

FEN

IX E

STAT

ESBU

ILD

ING

S 1

& 2

- PH

ASE

IH

OUS

TON

, TEX

AS

4630 N Loop 1604 West, Suite 201

San Antonio, Texas 78249

210.530.7000 F:210.377.1575

TBPE Firm Registration: F-903

ADDENDUM #3

306.01.2016

N

1/4" = 1'-0" 4ELECTRICAL ENLARGED PLAN - FIRE PUMP AND ELECTRICAL ROOMS

E4.00

ELEC

TRIC

AL E

NLA

RGED

PLAN

S

1/4" = 1'-0" 3ENLARGED PLAN - TYPICAL 1 BR ELECTRICAL PLAN

1/4" = 1'-0" 1ENLARGED PLAN - TYPICAL EFF-1 ELECTRICAL PLAN

1/4" = 1'-0" 2 ENLARGED PLAN - TYPICAL EFF-2 ELECTRICAL PLAN

O

6

AST

1T E

T E

SREGI

CENERR

T

RED

F T4 3 6

E XAS

CH

IM

S.D

HT

IT ECT

RA

E

OwnerHARRIS COUNTY HOUSING AUTHORITY8933 INTERCHANGE, HOUSTON, TX 77054P. 713.669.4514

Structural EngineersMISSION ENGINEERING, INC.102060 WESTHEIMER ROAD #585, HOUSTON, TX 77042P. 713.961.0018

ArchitectSMITH & COMPANY ARCHITECTS, INC.1500 MCGOWEN STREET #200, HOUSTON, TX 77004P. 713.524.4202 F. 713.524.4071

MEP/FP EngineersTTG CORP.13105 N.W. FREEWAY #690, HOUSTON, TX 77040P. 713.896.6990

Civil EngineersTRW ENGINEERING3300 S. GESSNER ROAD #100, HOUSTON, TX 77063P. 713.784.7777

Information/TechnologyConsultantDATACOM DESIGN GROUP8100 WASHINGTON AVENUE #260, HOUSTON, TX 77007P. 713.589.9797

HARRIS COUNTY PUBLIC INFRASTRUCTURE DEPARTMENTARCHITECTURE / ENGINEERING DIVISION

Landscape ArchitectKNUDSON LP8588 KATY FREEWAY #441, HOUSTON, TX 77024P. 713.463.8200

HOUSTON, TEXASS&C PROJECT NO.032415N

MAY 20, 2016

GENE LOCKECOMMISSIONER PRECINCT 1

JACK NORMANCOMMISSIONER PRECINCT 2

BARBARA J. SCHOTTCOUNTY AUDITOR

STEVE RADACKCOMMISSIONER PRECINCT 3

R. JACK CAGLECOMMISSIONER PRECINCT 4

JOHN R. BLOUNT, P.E.COUNTY ENGINEER

ED EMMETTCOUNTY JUDGE

JOE ELLISVICE CHAIR

ROBERTO GONZALEZCOMMISSIONER

JOE VILLARREALCOMMISSIONER

GERALD WOMACKCOMMISSIONER

KERRY WRIGHTCHAIR

TOM MCCASLANDSECRETARY

HCHA BOARD OF DIRECTORS HARRIS COUNTY COMMISSIONERS COURT

ISSUED FOR BID

1

FLOORSCARPET (CPT)

CPT-1 MANUFACTURER: SHAW CONTRACT GROUPPRODUCT: NOBLE MATERIALS MODULAR/ RUNNING LINE/ ALCHEMY TILEPRODUCT #: 5T135-33100 COLOR: CARRARA SILVERSIZE:INSTALLATION NOTES: MONOLITHIC

CPT-2 MANUFACTURER: SHAW CONTRACT GROUPPRODUCT: NOBLE MATERIALS MODULAR/ RUNNING LINE/ FORM TILEPRODUCT #: 5T136-33100COLOR: CARRARA SILVERSIZE:INSTALLATION NOTES: MONOLITHIC

BASE WALLS CEILINGS MILLWORK

PORCELAIN/CERAMIC TILE (PCT)

PCT-1 MANUFACTURER: INTERCERAMICPRODUCT: MODE CERAMIC FLOOR TILEPRODUCT #:COLOR: SLATESIZE: 32x32"GROUT:INSTALLATION NOTES: *REFER TO FINISH PLANS FOR PATTERN

PCT-2 MANUFACTURER: INTERCERAMICPRODUCT: MODE CERAMIC FLOOR TILEPRODUCT #:COLOR: SLATESIZE: 32"x16"GROUT:INSTALLATION NOTES: *REFER TO FINISH PLANS FOR PATTERN

PCT-3 MANUFACTURER: INTERCERAMICPRODUCT: MODE CERAMIC FLOOR TILEPRODUCT #:COLOR: SLATESIZE: 32"x8"GROUT:INSTALLATION NOTES: *REFER TO FINISH PLANS FOR PATTERN

PCT-4 MANUFACTURER: INTERCERAMICPRODUCT: MODE CERAMIC FLOOR TILEPRODUCT #:COLOR: TITANSIZE: 16"x32"GROUT:INSTALLATION NOTES: 1/2 RUNNING BOND *REFER TO FINISH PLANS;CORRESPONDING BASE TRIM @ PAINTED WALLS CTB-3

PCT-5 MANUFACTURER: DALTILEPRODUCT: EXQUISITE GLAZED PORCELAIN FLOOR TILEPRODUCT #: CHANTILLY EQ11COLOR: CHANTILLY EQ11SIZE: 12x24GROUT: TBDINSTALLATION NOTES: 1/2 RUNNING BOND * REFER TO FINISH PLANS;CORRESPONDING BASE TRIM, CTB-1LOCATION: RESIDENT UNIT RESTROOM FLOORS

VINYL COMPOSITION TILE (VCT)

VCT-1 MANUFACTURER: ARMSTRONGPRODUCT: STRIATIONS W/ BIOSTRIDEPRODUCT #: T3603 TWILIGHTCOLOR: TWILIGHTSIZE: 12"x24"INSTALLATION NOTES:

LUXURY VINYL TILE (LVT)

LVT-1 MANUFACTURER: SHAW HARD SURFACEPRODUCT: GRAINPRODUCT #: 0364VCOLOR: COCOA 64103SIZE: 7"x48"INSTALLATION NOTES: 20 MIL FLOATING LVT, INSTALL PLANKS TO RUN THELENGTH OF SCHEDULED ROOMS

SEALED/STAINED CONCRETE (SC)

SC-1 MANUFACTURER: PRODUCT:PRODUCT #:COLOR:SIZE:INSTALLATION NOTES:

PORCELAIN/CERAMIC TILE BASE (CTB)

CTB-1 MANUFACTURER: DALTILEPRODUCT: GLAZED CERAMIC WALL TILEPRODUCT #: CHANTILLY EQ11 W/ MATCHING 6" COVE BASE & BULLNOSE TRIMCOLOR: CHANTILLY EQ11/ P-36C9TBSIZE: 6" COVE BASEGROUT: TBDINSTALLATION NOTES:

CTB-2 MANUFACTURER: INTERCERAMIC USAPRODUCT: MODE / PORCELAIN TILEPRODUCT #: COVE BASECOLOR: TITANSIZE: 6"x12" COVE BASEGROUT: TBDINSTALLATION NOTES: COVE BASE CORNERS AS NEEDED. NO BASE @ WET WALL

CTB-3 MANUFACTURER: RITTENHOUSE SQAUREPRODUCT: GLAZED WALL TILEPRODUCT #: 0190 (2) SEMI GLOSSCOLOR: ARCTIC WHITE 0190SIZE: 6"x12" COVE BASEGROUT:INSTALLATION NOTES:

PAINT (PT)

PT-1 MANUFACTURER: BENJAMIN MOORECOLOR: HC-172 REVERE PEWTERFINISH: FLATINSTALLATION NOTES:

PT-2 MANUFACTURER: BENJAMIN MOORECOLOR: CSP-110 VINTAGE PEWTERFINISH: FLATINSTALLATION NOTES:

PT-3 MANUFACTURER: BENJAMIN MOORECOLOR: 2122-10 DARK PEWTERFINISH: FLATINSTALLATION NOTES:

PT-4 MANUFACTURER: BENJAMIN MOORECOLOR: HC-166 KENDALL CHARCOALFINISH: FLATINSTALLATION NOTES:

PT-5 MANUFACTURER: BENJAMIN MOORECOLOR: OC-117 SIMPLY WHITEFINISH: FLATINSTALLATION NOTES: FOR PAINT COLORS CALLED OUT W/ " * "FOLLOWING THE SCHD. PAINT FINISH IN THE ROOM FINISH SCHEDULE,FINISH TO BE EPOXY PAINT; EXAMPLE: PT- #*

PT-6 MANUFACTURER: SHERWIN WILLIAMSCOLOR: SW7665 WALL STREETFINISH: FLATINSTALLATION NOTES: ACCENT PAINT @ LEVEL 1

PT-7 MANUFACTURER: BENJAMIN MOORECOLOR: HC-25 QUINCY TANFINISH: FLATINSTALLATION NOTES: ACCENT PAINT @ LEVEL 3

PT-8 MANUFACTURER: SHERWIN WILLIAMSCOLOR: SW6222 RIVERWAYFINISH: FLATINSTALLATION NOTES: ACCENT PAINT @ LEVEL 4

PT-9 MANUFACTURER: SHERWIN WILLIAMSCOLOR: SW6172 HARDWAREFINISH: FLATINSTALLATION NOTES: ACCENT PAINT @ LEVEL 4

PORCELAIN/CERAMIC WALL TILE (CWT)

CWT-1 MANUFACTURER: HORIZON TILEPRODUCT: URBANWOODPRODUCT #:COLOR: GREYSIZE: 6"x36"GROUT: TBDINSTALLATION NOTES: *NO BASE AT CWT-1 SCHD. TILED WALLS;*REFER TO INTERIOR ELAVATIONS; 1/2 RUNNING BOND PATTERN

CWT-2 MANUFACTURER: INTERCERAMICS USAPRODUCT: INTERGLASS SHIMMERPRODUCT #: SO.SHIM.RAIA.070.3045GLOS.1COLOR: RAINSIZE: 1" x 2"GROUT: TBDINSTALLATION NOTES: MOSAIC BACKSPLASH @ UNIT KITCHENS

CWT-3 MANUFACTURER: DALTILEPRODUCT: GLAZED CERAMIC WALL TILEPRODUCT #: CHANTILLY EQ11 W/ MATCHING 6"COVE BASE & BULLNOSE TRIMCOLOR: CHANTILLY EQ11SIZE: 12x18 WALL TILEGROUT: TBDINSTALLATION NOTES: 1/2 HORIZONTAL RUNNING BOND/ W/ MATCHINGBULLNOSE TRIM @ TOP AND SIDES OF SHOWER SURROUND,INSTALL TO 56" A.F.F. (HT. INCLUDES 6" COVE BASE & BULLNOSE TRIM)

CWT-4 MANUFACTURER: DALTILEPRODUCT: RITTENHOUSE SQUARE SEMI GLOSS WALL TILEPRODUCT #: 0190 (2) SEMI GLOSSCOLOR: ARCTIC WHITE 0190SIZE: 3" x 6"GROUT: TBDINSTALLATION NOTES: WALL TILE @ KITCHEN 138, FINISH TO BE FULLHEIGHT W/ MATCHING 6" COVE BASE.

CWT-5 MANUFACTURER: DALTILEPRODUCT: GLAZED CERAMIC WALL TILEPRODUCT #: CHANTILLY EQ11 W/ MATCHING 6" COVEBASE & BULLNOSE TRIMCOLOR: CHANTILLY EQ11SIZE: 2x4 MOSAICGROUT: TBDINSTALLATION NOTES: ABOVE SHOWERS IN LIVING UNIT R.R.'S, TOFINISHED CEILING, MATCHING TRIM @ EDGES, ALIGN EDGE OF TRIMTO EDGE OF SHOWER

CWT-6 MANUFACTURER: INTERCERAMICPRODUCT: MODE CERAMIC FLOOR TILEPRODUCT #:COLOR: SLATESIZE: 32"x8"GROUT:INSTALLATION NOTES: STACKED VERTICALLY

GYPSUM BOARD (GYP)

GYP-1 MANUFACTURER: PITTSBURGH PAINTS (PPG)COLOR: PT-5FINISH:INSTALLATION NOTES:

GYP-2 MANUFACTURER: PITTSBURGH PAINTS (PPG)COLOR: PT-5FINISH: EPOXY PAINT FINISH (WET AREAS ONLY)INSTALLATION NOTES:

PLASTIC LAMINATE (PL)

PL-1 MANUFACTURER: WILSONARTPRODUCT: STANDARD LAMINATEPRODUCT #: 7960K-18COLOR: STUDIO TEAKFINISH: LINEARITY FINISH WITH AEON™INSTALLATION NOTES: GRAIN TO RUN VERTICALLY ON ALL CASEWORK, W/ MATCHING DOELSKIN/PVC EDGEBAND

PL-2 MANUFACTURER: WILSONARTPRODUCT: PREMIUM LAMINATEPRODUCT #: 4971K-52COLOR: BRONZITEFINISH: QAURRY FINISH W/ AEON™INSTALLATION NOTES: LAMINATE @ SCHD. COUNTERTOPSEDGE TO HAVE 1.25" MATCHING DOELSKIN EDGEBAND

PL-3 MANUFACTURER: WILSONARTPRODUCT: STANDARD LAMINATEPRODUCT #: 7997-38COLOR: EBONY RECONFINISH: INEARITY FINISH WITH AEON™INSTALLATION NOTES: GRAIN TO RUN VERTICALLY ON ALL CASEWORK, W/ MATCHING DOELSKIN/PVC EDGEBAND

PL-2 MANUFACTURER: WILSONARTPRODUCT: DECORATIVE METALPRODUCT #: M-6261COLOR: SATIN BRUSHED LITE BRONZE ALUMINUMFINISH: SATIN BRUSHEDINSTALLATION NOTES:

ACCOUSTIC CEILING TILE (ACT)

ACT-1 MANUFACTURER: ARMSTRONG (OR EQAUL)PRODUCT: ULTIMA HIGH NRC BEVELED TEGULARPRODUCT #: 1942ZWCOLOR: BLIZZARD WHITESIZE: 24x24GRID SYSTEM: SILHOUETTE XL 1/8" REVEAL 9/16" SLOTTED TEE SYSTEMTRIM: 7804ZWINSTALLATION NOTES:

WOOD (WD)

WD-3 MANUFACTURER: ELMWOOD RECLAIMED TIMBERPRODUCT: RUSTIC WHITE OAK RECLAIMED WOOD SHELVESPRODUCT #:COLOR: RUSTIC WHITE OAKSIZE: 36W "x 2"HINSTALLATION NOTES:

WD-4 MANUFACTURER: HARDWARE RESOURCESPRODUCT: P35MP SQUARE MODERN WOOD POST ISLANDLEG, ALL MOULDING PRODUCT, HARD MAPLE.REINFORCED AND SECURED TO ISLAND COUNTERSUBSTRATE.PRODUCT #: P35MPCOLOR: STAINED TO MATCH PL-1SIZE: 2'-8 1/2"INSTALLATION NOTES:

WD-5 MANUFACTURER: ELMWOOD RECLAIMED TIMBERPRODUCT: ANTIQUE ROUGH SAWN DIMENSIONAL LUMBERPRODUCT #:COLOR: VARIES (ORDER BEST MATCH TO WD-1)FINISH: THE WORKS (DENAIL, POWERWASH AND KILN DRIED)SIZE: 1" THICK x (SEE ELEVATION FOR HT.)INSTALLATION NOTES: LUMBER VARIES IN CHARACHTER AND SHADE, BESTMATCH TO WD-1 AND CLEAR COAT FINISH

QUARTZ STONE (QTZ)

QTZ-1 MANUFACTURER: WILSONARTPRODUCT: QUARTZPRODUCT #: ARASHI Q4011COLOR: ARASHIFINISH:INSTALLATION NOTES: 1 - 1/2" EASED EDGE

QTZ-2 MANUFACTURER: CAMBRIAPRODUCT: QUARTZPRODUCT #: 2CM TORQUAYCOLOR: TORQUAYFINISH:INSTALLATION NOTES: 1 - 1/2" EASED EDGE

SOLID SURFACE (SSF)

SSF-1 MANUFACTURER: DUPONTPRODUCT: CORIANPRODUCT #:COLOR: RAIN CLOUDFINISH:INSTALLATION NOTES: 1- 1/2" EASED EDGE

SSF-2 MANUFACTURER: DUPONTPRODUCT: CORIANPRODUCT #:COLOR: DESIGNER WHITEFINISH:INSTALLATION NOTES: 1- 1/2" EASED EDGE

WD-1 MANUFACTURER: ELMWOOD RECLAIMED WOODPRODUCT: RECLAIMED OLD GROWTH WHITE OAK COUNTRY SELECT PANELINGPRODUCT #:COLOR: WHITE OAK COUNTRY SELECTSIZE: 3in x 12ft x 1/2"INSTALLATION NOTES: TOUNGE AND GROOVE, RANDOM ASHLARPATTERN, DIRECT GLUE TO 3/4" TREATED PLY WD. SUBSTRATE

WOOD BASE (WB)

WB-1 MANUFACTURER: BISON BUILDING SUPPLY WOOD PRODUCT: SOLID PINE BASEBOARD B218-5PRODUCT #: B218-5COLOR: PAINTED, PT-4SIZE: 5 - 1/4"INSTALLATION NOTES:

WB-2 NOT USED

WB-3 MANUFACTURER: N/A PRODUCT: 1x6 PRIMED AND TREATED FLAT LUMBER BASEBOARD TRIMPRODUCT #: N/ACOLOR: PAINTED, PT-4*NOMINAL SIZE: 3/4"D x 5- 1/2"HINSTALLATION NOTES:

WOOD CEILING (WD)

WD-2 MANUFACTURER: ELMWOOD RECLAIMED TIMBERPRODUCT: RUSTIC PINE FAUX WOOD BEAMSPRODUCT #:COLOR: VARIES* (RECLAIMED TIMBER SKINS VARY)SIZE: 8" x 8" x (SEE RCP/ FIELD VERIFY LENGTH)INSTALLATION NOTES:

MELAMINE (ML)

ML-1 MANUFACTURER: PREMIERE EUROCASEPRODUCT: THERMOFUSED LAMINATE PANELS (PREMIER MELAMINE)PRODUCT #: N/ACOLOR: DESIGNER WHITEFINISH: N/ASIZE: 8' x 2" 90 DEGREEINSTALLATION NOTES:

RUBBER BASE (RB)

RB-1 MANUFACTURER: ALLSTATE RUBBERPRODUCT: 4" COVE RUBBER BASEPRODUCT #:COLOR: D48SIZE: 4"INSTALLATION NOTES:

FIBER REINFORCED PANEL (FRP)

FRP-1 MANUFACTURER: MARLITEPRODUCT: FIBER REINFORCED PANELPRODUCT #: STANDARD FRPCOLOR: WHITEFINISH: N/ASIZE: 4'x8'INSTALLATION NOTES: INSTALL VERTICALLY, SCHD. PAINTED GYPSUM ABOVE,W/ MATCHING PVC TRIM

WOOD (WD)

WOOD FLOORS (WDF)

WDF-1 MANUFACTURER: ARMSTRONGPRODUCT:PRODUCT #:COLOR:SIZE:INSTALLATION NOTES:

SHEET VINYL (SV)

SV-1 MANUFACTURER: REF. TO SPECSPRODUCT: WOOD LOOK SHEET VINYLPRODUCT #:COLOR: CLOSE MATCH TO LVT-1; CONTRACTOR TO PROVIDE COLORSFOR ARCHITECT APPROVALSIZE: AS SPECIFIED IN SPECSINSTALLATION NOTES:

FINISH SCHEDULE 1NO SCALE

HOUSTON, TEXAS 770041500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202FAX: 713-524-4071www.sc-arch.com

O

6

AST

1T E

TE

SREGI

CENERR

T

RED

F T436

EXAS

CH

IMS

.D

HT

ITECT

RA

E

DATE ISSUED:

REVISIONS:

MAY 20, 2016

5/27/2016 11:45:11 AM C:\Users\jwhite\Documents\FENIX ESTATES - PHASE II_jwhite.rvt

A3 .11

PROJECT NUMBER:032415N

MAY 20, 2016

MA

TER

IALS

SC

HED

ULE

FEN

IX E

STA

TES

- P

HA

SE I

IH

OU

STO

N,

TEX

AS

NO. DATE DESCRIPTION

1 06/2/2016 ADDENDUM 3

1

NO SCALEABBREVIATIONS 2

NO SCALEGENERAL NOTES 1

PL PLASTIC LAMINATE

WV WOOD VENEER

W1 SOLID WOOD TRIM

GL GLASS

CAA CLEAR ANODIZED ALUMINUM

BAA BRONZE ANODIZED ALUMINUM

P PAINT

RE: 1/A3.10 FOR FINISH SCHEDULE

SC SOLID CORE WOOD

HM HOLLOW METAL

AL ALUMINUM

WD WOOD

1. REFER TO SHEET A4.01 FOR WINDOW TYPES AND GLAZING SCHEDULE

2. REFER TO SHEET'S A2.20, A2.21, & A2.22 FOR DOOR INFORMATION AT LIVING UNITS

3. REFER SPECIFICATIONS FOR HARDWARE SETS AND PRODUCT DATA

4. REFER TO THE SPECIFICATIONS FOR DOOR HARDWARE FOR DEMOUNTABLEPARTITION DOORS.

DOOR SCHEDULE 6NO SCALE

DOOR SCHEDULE

DO

OR

NU

MB

ER

DO

OR

FIN

ISH

FR

AM

E F

INIS

H

DOOR SIZE

DO

OR

TH

K.

FR

AM

E T

YP

E

DO

OR

TY

PE

HEAD JAMB SILL HA

RD

WA

RE

SE

TS

REMARKSWIDTH HEIGHT

LEVEL 1100-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A F 16/A3.21 17/A3.21 10C/A3.21 03 45 MINUTE RATED

101A-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B1 15/A3.21 15/A3.21 10D/A3.21 08 20 MINUTE RATED101B-B3 P P 6' - 0" 7' - 0" 0' - 1 3/4" A E 16/A3.21 17/A3.21 10C/A3.21 07 45 MINUTE RATED102A-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A F 6/A3.22 6/A3.22 10D/A3.21 15B 90 MINUTE RATED102B-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A A 16/A3.21 17/A3.21 10C/A3.21 03 90 MINUTE RATED103-B3 GL P 3' - 0" 7' - 0" 0' - 1 3/4" C B1 7/A3.21 6/A3.21 10D/A3.21 11 20 MINUTE RATED

111A-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B1 8/A3.21 8/A3.21 10D/A3.21 14A 45 MINUTE RATED111B-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A A 1/A3.22 1/A3.22 10C/A3.21 03 90 MINUTE RATED113-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B1 8/A3.21 8/A3.21 10D/A3.21 13A 20 MINUTE RATED115-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B1 8/A3.21 8/A3.21 10D/A3.21 13A 20 MINUTE RATED117-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B F1 8/A3.21 8/A3.21 10D/A3.21 08 20 MINUTE RATED

119A-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A F 6/A3.22 6/A3.22 10D/A3.21 15B 90 MINUTE RATED119B-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A F 1/A3.22 2/A3.22 10C/A3.21 03 90 MINUTE RATED120A-B3 GL BAA 3' - 0" 7' - 0" 0' - 1 3/4" D D 13/A3.21 14/A3.21 10C/A3.21 01A 45 MINUTE RATED120B-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 8/A3.21 10D/A3.21 03 20 MINUTE RATED121-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 8/A3.21 10D/A3.21 13 20 MINUTE RATED122-B3 GL BAA 3' - 0" 7' - 0" 0' - 1 3/4" C F 1/A3.22 2/A3.22 10C/A3.21 03 45 MINUTE RATED124-B3 PL-3 BAA 3' - 0" 7' - 0" 0' - 1 3/4" C B 7/A3.21 6/A3.21 10D/A3.21 13A125-B3 PL-3 BAA 3' - 0" 7' - 0" 0' - 1 3/4" C B 7/A3.21 6/A3.21 10D/A3.21 10

126A-B3 GL BAA 6' - 0" 7' - 0" 0' - 1 3/4" D D 7/A3.21 6/A3.21 10D/A3.21 02A127-B3 GL BAA 3' - 0" 7' - 0" 0' - 1 3/4" D D 7/A3.21 6/A3.21 10D/A3.21 02A

128A-B3 GL BAA 3' - 0" 7' - 0" 0' - 1 3/4" D D 13/A3.21 14/A3.21 10C/A3.21 01A 45 MINUTE RATED128B-B3 GL BAA 3' - 0" 7' - 0" 0' - 1 3/4" D D 13/A3.21 14/A3.21 10C/A3.21 01A 45 MINUTE RATED129-B3 GL BAA 6' - 0" 7' - 0" 0' - 1 3/4" D D 1/A3.22 2/A3.22 10C/A3.21 01A 45 MINUTE RATED130-B3 PL-3 BAA 3' - 0" 7' - 0" 0' - 1 3/4" C B 7/A3.21 6/A3.21 10D/A3.21 11134-B3 PL-3 BAA 3' - 0" 7' - 0" 0' - 1 3/4" C B 7/A3.21 6/A3.21 10D/A3.21 17A135-B3 PL-3 BAA 3' - 0" 7' - 0" 0' - 1 3/4" C B 7/A3.21 6/A3.21 10D/A3.21 17A

136A-B3 GL BAA 3' - 0" 9' - 0" 0' - 1 3/4" D D 7/A3.21 6/A3.21 10D/A3.21 10A136B-B3 PL-3 BAA 3' - 0" 7' - 0" 0' - 1 3/4" C B 7/A3.21 6/A3.21 10D/A3.21 11139-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A F 16/A3.21 17/A3.21 10C/A3.21 03 45 MINUTE RATED

141A-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A F 6/A3.22 6/A3.22 10D/A3.21 15B 90 MINUTE RATED141B-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A F 16/A3.21 17/A3.21 10C/A3.21 03 90 MINUTE RATED145-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" A B 15/A3.21 15/A3.21 10D/A3.21 13146-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" A B 15/A3.21 15/A3.21 10D/A3.21 13

LEVEL 2201-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B1 15/A3.21 15/A3.21 10D/A3.21 08 20 MINUTE RATED202-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B 6/A3.22 6/A3.22 10D/A3.21 15B 90 MINUTE RATED203-B3 GL P 3' - 0" 7' - 0" 0' - 1 3/4" C B1 7/A3.21 6/A3.21 10D/A3.21 18 20 MINUTE RATED211-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B1 8/A3.21 9/A3.21 10D/A3.21 14A 20 MINUTE RATED213-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B1 8/A3.21 9/A3.21 10D/A3.21 13A 20 MINUTE RATED215-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B1 8/A3.21 9/A3.21 10D/A3.21 08 20 MINUTE RATED217-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B 6/A3.22 6/A3.22 10D/A3.21 15B 90 MINUTE RATED219-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 9/A3.21 10D/A3.21 13 20 MINUTE RATED221-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 9/A3.21 10D/A3.21 13A 20 MINUTE RATED228-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 9/A3.21 10D/A3.21 13A 20 MINUTE RATED235-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 9/A3.21 10D/A3.21 14A 20 MINUTE RATED237-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 9/A3.21 10D/A3.21 13A 20 MINUTE RATED241-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B 6/A3.22 6/A3.22 10D/A3.21 15B 90 MINUTE RATED

LEVEL 3301-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B1 15/A3.21 15/A3.21 10D/A3.21 08 20 MINUTE RATED302-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B 6/A3.22 6/A3.22 10D/A3.21 15B 90 MINUTE RATED303-B3 GL P 3' - 0" 7' - 0" 0' - 1 3/4" C B1 7/A3.21 6/A3.21 10D/A3.21 18 20 MINUTE RATED311-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B1 8/A3.21 9/A3.21 10D/A3.21 14A 20 MINUTE RATED313-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B1 8/A3.21 9/A3.21 10D/A3.21 13A 20 MINUTE RATED315-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B1 8/A3.21 9/A3.21 10D/A3.21 08 20 MINUTE RATED317-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B 6/A3.22 6/A3.22 10D/A3.21 15B 90 MINUTE RATED319-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 9/A3.21 10D/A3.21 13 20 MINUTE RATED321-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 9/A3.21 10D/A3.21 13A 20 MINUTE RATED328-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 9/A3.21 10D/A3.21 13A 20 MINUTE RATED335-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 9/A3.21 10D/A3.21 14A 20 MINUTE RATED337-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 9/A3.21 10D/A3.21 13A 20 MINUTE RATED341-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B 6/A3.22 6/A3.22 10D/A3.21 15B 90 MINUTE RATED

LEVEL 4401-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B1 15/A3.21 15/A3.21 10D/A3.21 08 20 MINUTE RATED402-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B 6/A3.22 6/A3.22 10D/A3.21 15B 90 MINUTE RATED403-B3 GL P 3' - 0" 7' - 0" 0' - 1 3/4" C B1 7/A3.21 6/A3.21 10D/A3.21 18 20 MINUTE RATED417-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B 6/A3.22 6/A3.22 10D/A3.21 15B 90 MINUTE RATED419-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 9/A3.21 10D/A3.21 13 20 MINUTE RATED421-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 9/A3.21 10D/A3.21 13A 20 MINUTE RATED428-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 9/A3.21 10D/A3.21 13A 20 MINUTE RATED435-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 9/A3.21 10D/A3.21 14A 20 MINUTE RATED437-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 9/A3.21 10D/A3.21 13A 20 MINUTE RATED441-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B 6/A3.22 6/A3.22 10D/A3.21 15B 90 MINUTE RATED

LEVEL 5501-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B1 15/A3.21 15/A3.21 10D/A3.21 08 20 MINUTE RATED502-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B 6/A3.22 6/A3.22 10D/A3.21 15B 90 MINUTE RATED503-B3 GL P 3' - 0" 7' - 0" 0' - 1 3/4" C B1 7/A3.21 6/A3.21 10D/A3.21 18 20 MINUTE RATED511-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B1 8/A3.21 9/A3.21 10D/A3.21 14A 20 MINUTE RATED513-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B1 8/A3.21 9/A3.21 10D/A3.21 13A 20 MINUTE RATED515-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B1 8/A3.21 9/A3.21 10D/A3.21 13A 20 MINUTE RATED517-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B F1 8/A3.21 9/A3.21 10D/A3.21 08 20 MINUTE RATED519-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B 6/A3.22 6/A3.22 10D/A3.21 15B 90 MINUTE RATED520-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 9/A3.21 10D/A3.21 13A 20 MINUTE RATED521-B3 PL-3 P 3' - 0" 7' - 0" 0' - 1 3/4" B B 8/A3.21 9/A3.21 10D/A3.21 13 20 MINUTE RATED522-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B 6/A3.22 6/A3.22 10D/A3.21 15B 90 MINUTE RATED523-B3 PL-3 BAA 3' - 0" 7' - 0" 0' - 1 3/4" C B 7/A3.21 6/A3.21 10D/A3.21 13A 20 MINUTE RATED527-B3 GL P 3' - 0" 7' - 0" 0' - 1 3/4" C B1 7/A3.21 6/A3.21 10D/A3.21 16A 20 MINUTE RATED533-B3 PL-3 BAA 3' - 0" 7' - 0" 0' - 1 3/4" C B 7/A3.21 6/A3.21 10D/A3.21 17 20 MINUTE RATED534-B3 PL-3 BAA 3' - 0" 7' - 0" 0' - 1 3/4" C B 7/A3.21 6/A3.21 10D/A3.21 17 20 MINUTE RATED541-B3 P P 3' - 0" 7' - 0" 0' - 1 3/4" A B 6/A3.22 6/A3.22 10D/A3.21 15B 90 MINUTE RATED552-B3 PL-3 BAA 3' - 0" 7' - 0" 0' - 1 3/4" C B 7/A3.21 6/A3.21 10D/A3.21 08 20 MINUTE RATED

HOUSTON, TEXAS 770041500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202FAX: 713-524-4071www.sc-arch.com

O

6

AST

1T E

TE

SREGI

CENERR

T

RED

F T436

EXAS

CH

IMS

.D

HT

ITECT

RA

E

DATE ISSUED:

REVISIONS:

MAY 20, 2016

5/26/2016 7:11:50 AM C:\Users\jwhite\Documents\FENIX ESTATES - PHASE II_jwhite.rvt

A3 .20

PROJECT NUMBER:032415N

MAY 20, 2016

DO

OR

SC

HED

ULE

FEN

IX E

STA

TES

- P

HA

SE I

IH

OU

STO

N,

TEX

AS

NO. DATE DESCRIPTION

1 06/2/2016 ADDENDUM 3

1

1

gov

gov

gov

gov

FILE RM.147-B3

BOARD ROOM126A-B3

ELEVATORVESTIBULE

129-B3

CONFERENCE RM.127-B3

STORAGE125-B3

STORAGE RM.145-B3

SECURE FILE146-B3

OFFICE #1143-B3

STAIR A141-B3

SERVER ROOM124-B3

ENTRYVESTIBULE

120-B3

OFFICE #4149-B3

OFFICE #3148-B3

OFFICE #2142-B3

UNISEX R.R.135-B3

UNISEX R.R.134-B3

WOMEN'S R.R.132-B3

MEN'S R.R.131-B3

INTAKEWORKERS

136-B3

WO

RK R

OO

M13

3-B

3

CORRIDOR122-B3

CORRIDOR123-B3

CORRIDOR130-B3

LOBBY128-B3

CORR

IDO

R13

8-B

3

CORRIDOR137-B3

CORR

IDO

R14

0-B

3

CORR

IDO

R15

0-B

3

SUITE B151-B3

SUITE A144-B3

CORRIDOR139-B3

WD-1

CWT-1

CWT-1

CWT-1

CWT-1

CWT-1

CWT-1

PCT-3

PCT-2PCT-4

PCT-4

PC

T-3

PCT-2

DAIS126C-B3

IDF126B-B3

CORRIDOR100-B3

PT-6

PT-6

PT-6

PT-6

PT-6 (TYP.)

1

1

1

1

1

1

1

1

1

2

2

2

2

3

3

444

55

6

6

6

6

4

5

5

3

PT

-6

PT-6

PC

T-3

PCT-2 PC

T-3

PCT-2

PCT-1

PCT-3

PCT-1

4 4

4

WD-1

WD-1

MK-1

WD-1

PT-3

PT-3PT-3

WDF-1+0'-7"

PT

-3

WDF-1

PCT-1

PT-3PT-3

2

2

2

2

2

2

22

2

2

2

ELEVATORLOBBY528-B3

ELEV 1554-B3

CEO535-B3

OFFICE #6543-B3

OFFICE #7544-B3

OFFICE #8546-B3

OFFICE #9545-B3

OFFICE #10547-B3

OFFICE #11548-B3

OFFICE #12551-B3

FILE RM.552-B3

STAIR A541-B3

STAIR B519-B3

CONFERENCE RM.530-B3

WOMEN'S534-B3

MEN'S533-B3

OFFICE #13538-B3

OFFICE #14537-B3

BREAK ROOM527-B3

OFFICE #15524-B3

STORAGE RM.523-B3

RECEPTION531-B3

WORK POOLSOUTH525-B3

CORRIDOR536-B3

CORRIDOR539-B3

CORRIDOR542-B3CORRIDOR

549-B3

CORRIDOR550-B3

WORK POOLCENTRAL

540-B3

WORK POOLNORTH553-B3

CORRIDOR522-B3

CORRIDOR526-B3

3 3

3

3

3 3 3

3

3 33

PT-6

PT-6

PT-6

PL-

3

4

4

4

4

4

4 4

4 4

4

4

PT-6

PT-6

PT

-6P

T-6 C

WT

-4

MK-1

PL-3 PL-

6

PT

-6

66

7 8

7

7 8

7 8

5

5 5

5 5

55

5 5

5

3

4

4

44

4 4

4

PT-6

PT-6

PT

-6

PT-6

CW

T-1

CW

T-1

2

2

2

2

2

22

2

2

2

2 2

2 2

2

2 2 2

2

2

2

2

2

5

5

GENERAL NOTES - FINISHES 1NO SCALE

2. REFER TO MATERIALS SCHEDULE ON A3.11 FOR SCHEDULEDMATERIALS AND FINISHES

1. ALL WALLS TO BE PAINTED PT-1, U.N.O.

KEY NOTES 2NO SCALE

2 SCHLUTER METAL TRANSITION @ ALL CHANGES IN FLOORINGMATERIAL TRANSITIONS, U.N.O.

1 GYP. CEILING AND SIDE WALLS @ CASEWORK STATIONS TO BE, PT-6

3 COLUMN WRAPS TO BE, WD-5

4 COLUMN WRAPS TO BE PAINTED GYP., PT-6

5 REF. TO INTERIOR ELEVATIONS FOR DEMOUNTABLE PARTITIONTYPES AND ASSOCIATED MATERIALS AND FINISHES.

6 CERAMIC BASE AT PAINTED WALLS ONLY, CTB-2.

7 VAULTED CEILINGS TO BE, GYP-1

8 FAUX CEILING BEAMS @ CEILING TO BE WD-2, REF. TORCP'S FOR ADDT'L INFO.

FINISH PLAN LEGEND 3NO SCALE

VINYL WOOD FLOORING (LVT)

WOOD FLOORING (WDF)

32" TILE

32"x16" TILE

8" 32" TILE

CARPET

HOUSTON, TEXAS 770041500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202FAX: 713-524-4071www.sc-arch.com

O

6

AST

1T E

TE

SREGI

CENERR

T

RED

F T436

EXAS

CH

IMS

.D

HT

ITECT

RA

E

DATE ISSUED:

REVISIONS:

MAY 20, 2016

5/26/2016 8:15:18 AM C:\Users\jwhite\Documents\FENIX ESTATES - PHASE II_jwhite.rvt

A9 .10

PROJECT NUMBER:032415N

MAY 20, 2016

ENLA

RG

ED F

INIS

H P

LAN

SFE

NIX

EST

AT

ES -

PH

ASE

II

HO

UST

ON

, T

EXA

S

1/8" = 1'-0" 6ENLARGED FINISH FLOOR PLAN - LEVEL 1 1/8" = 1'-0" 19ENLARGED FINISH FLOOR PLAN - LEVEL 5

NO. DATE DESCRIPTION

1 06/2/2016 ADDENDUM 3

1

11 SPACES

14 SPACES

3 SPACES

20 SPACES

22 SPACES

HUSSION STREET

HUSSION STREET

CO

YL

E S

TR

EE

T

12 SPACES

24 SPACES

4 SPACES

12 SPACES BUILDING 3

NOT IN SCOPE

WIN

CH

ESTE

R S

TREET (P

VT)

BU

ILDIN

G 1

BU

ILDIN

G 2

4 SPACES

13 S

PACE

S

6 SPACES

BIK

E REN

TAL

DATE ISSUED:

REVISIONS:

10/1/2015 4:00:08 PM C:\Users\jwhite\Documents\FENIX ESTATES - PHASE II_jwhite.rvt

L3.00

PROJECT NUMBER:032415N

FURN

ISH

ING

PLA

NPH

ASE

II

FEN

IX E

STAT

ESBU

ILD

ING

3 -

PH

ASE

IIH

OUS

TON

, TEX

AS

NO. DATE DESCRIPTION

1" = 30'-0" 1FURNISHING PLAN (PHASE II)

N

HOUSTON, TEXAS 770041500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202FAX: 713-524-4071www.sc-arch.com

MAY 20, 2016

MAY 20, 2016

ER

AT T

EGI

S

S

ERT

XT EE FO

R

AS

ETTC

CIH

02 5 7

SDNAD L PEACA

BRYA

N PAUL JANHSEN

1 6/2/2016 ADDENDUM 3

1

1

AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
F
AutoCAD SHX Text
F
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
C
AutoCAD SHX Text
J
AutoCAD SHX Text
I
AutoCAD SHX Text
I
AutoCAD SHX Text
J
AutoCAD SHX Text
I
AutoCAD SHX Text
I
AutoCAD SHX Text
K
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
L
AutoCAD SHX Text
L
AutoCAD SHX Text
L
AutoCAD SHX Text
L
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
O
AutoCAD SHX Text
O
AutoCAD SHX Text
O
AutoCAD SHX Text
O
AutoCAD SHX Text
O
AutoCAD SHX Text
O
AutoCAD SHX Text
O
AutoCAD SHX Text
O
AutoCAD SHX Text
O
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
F
AutoCAD SHX Text
F
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
P
AutoCAD SHX Text
25 L.F.
AutoCAD SHX Text
P
AutoCAD SHX Text
130 L.F.
AutoCAD SHX Text
P
AutoCAD SHX Text
58 L.F.
AutoCAD SHX Text
PHASE I - LANDSCAPE
AutoCAD SHX Text
PHASE II - LANDSCAPE
AutoCAD SHX Text
316.5'
AutoCAD SHX Text
17.5'
AutoCAD SHX Text
71.5'
AutoCAD SHX Text
117.5'
AutoCAD SHX Text
134.5'
AutoCAD SHX Text
166.83'
AutoCAD SHX Text
47.5'
AutoCAD SHX Text
126.08'
AutoCAD SHX Text
150.0'
AutoCAD SHX Text
100.0'
AutoCAD SHX Text
98.9'
AutoCAD SHX Text
41.5'
AutoCAD SHX Text
29.75'
AutoCAD SHX Text
325.9'
AutoCAD SHX Text
9.83'
AutoCAD SHX Text
62.5'
AutoCAD SHX Text
74.75'
AutoCAD SHX Text
107.0'
AutoCAD SHX Text
98.66'
AutoCAD SHX Text
FIRE HYDRANT
AutoCAD SHX Text
FENCE AND GATE SCHEDULE:
AutoCAD SHX Text
6' - ORNAMENTAL FENCING (BLACK) MONTAGE PLUS, WARRIOR 3R EXT 6'T, 8' PANEL AS MANUFACTURED BY AMERISTAR FENCE PRODUCTS OF APPROVED EQUAL. (BASE BID)
AutoCAD SHX Text
MASONRY FENCE COLUMN - (BASE BID) RE: DETAIL. VENEER MATERIAL TO MATCH BUILDING FACADE
AutoCAD SHX Text
PEDESTRIAN GATES - MONTAGE PLUS WARRIOR STYLE PEDESTRIAN GATE, - MONTAGE PLUS WARRIOR STYLE PEDESTRIAN GATE, 6'HT 40" OTO SGL GATE. AS MANUFACTURED BY AMERISTAR FENCE PRODUCTS (REP- BRAD CHANDLER - 888-333-3422) OR APPROVED EQUAL. WITH HEAVY DUTY, NON LOCKING LEVER LOCK SET (MASTER LOCK #33M214, OR APPROVED EQUAL)
AutoCAD SHX Text
6' - CHAIN LINK FENCE WITH PRIVACY FABRIC. CHAIN LINK TO BE 10 GAUGE GALVANIZED WIRE. REFER TO SPEC 323133 THIS ITEM IS A DEDUCT ALTERNATE TO THE ORNAMENTAL FENCING. IF THE BASE BID (ORNAMENTAL FENCE) IS NOT ACCEPTED. REFER TO PLANS FOR EXTENT OF CHAIN LINK FENCE INCLUDED IN DEDUCT ALTERNATE.
AutoCAD SHX Text
MASONRY FENCE COLUMN - (DEDUCT ALTERNATE) FOR THE MASONRY FENCE COLUMNS. IF THE BASE BID IS NOT ACCEPTED, STANDARD METAL FENCE COLUMN WILL BE PROVIDED. REFER TO PLANS FOR MASONRY COLUMNS ELIMINATED IN THE DEDUCT ALTERNATE.
AutoCAD SHX Text
KEY
AutoCAD SHX Text
ITEM DESCRIPTION
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
VEHICULAR GATES - 6'HT, MONTAGE PLUS WARRIOR STYLE, 14' SPAN, SINGLE - 6'HT, MONTAGE PLUS WARRIOR STYLE, 14' SPAN, SINGLE LEAF GATE. AS MANUFACTURED BY AMERISTAR FENCE PRODUCTS (REP- BRAD CHANDLER - 888-333-3422) OR APPROVED EQUAL. OPENER TO BE 'AMERISTAR GATE SYSTEMS' #6500 AGS (1/2 HP). ALL ASSEMBLIES AND DETECTOR LOOP PER MANUFACTURER'S RECOMMENDATION.
AutoCAD SHX Text
GREEN SCREEN FENCING - FENCE TO BE INSTALLED 12"-18" FROM SIDEWALK WITH POST SPACING OF 4' ON CENTER. PROVIDE ALL FENCE PANELS, POSTS, BRACKETS AND ACCESSORIES. FENCE TO BE 4' CONTEMPO BY DESIGN MASTER FENCE (800-332-2373) OR APPROVED EQUAL. COLOR TO BE BLACK. INSTALLED PER MFGR'S RECOMMENDED PRACTICES.
AutoCAD SHX Text
P
AutoCAD SHX Text
SITE FURNISHINGS SCHEDULE:
AutoCAD SHX Text
RECEPTACLE - DUMOR MODEL #438-32 FTO, S-2 SURFACE MOUNT, 32 GAL LINER WITH 10" OPENING. COLOR TO BE SELECTED BY OWNER.
AutoCAD SHX Text
BENCH - DUMOR MODEL #118-60. BACKED BENCH, S-2 SURFACE MOUNT. COLOR TO BE SELECTED BY OWNER.
AutoCAD SHX Text
KEY
AutoCAD SHX Text
ITEM DESCRIPTION
AutoCAD SHX Text
SPECIALTY SURFACES SCHEDULE:
AutoCAD SHX Text
KEY
AutoCAD SHX Text
ITEM DESCRIPTION
AutoCAD SHX Text
DECOMPOSED GRANITE GROUND COVER - 4" LAYER AFTER COMPACTIONS RE: DETAIL
AutoCAD SHX Text
(BASE BID) HEADER COURSE, CONCRETE UNIT PAVERS - 80 MM HOLLAND STONE BY PAVESTONE OR APPROVED EQUAL. COLOR BY OWNER. RE: DETAIL (DEDUCT ALTERNATE) - STANDARD PARKING LOT PAVING WITH NO PAVERS
AutoCAD SHX Text
(BASE BID) FIELD COURSE, CONCRETE UNIT PAVERS - 80 MM HOLLAND STONE, 45 DEGREE HERRING BONE PATTERN, BY PAVESTONE OR APPROVED EQUAL. RE: DETAIL (DEDUCT ALTERNATE) - STANDARD PARKING LOT PAVING WITH NO PAVERS
AutoCAD SHX Text
I
AutoCAD SHX Text
J
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
4" STEEL EDGING RE: DETAIL
AutoCAD SHX Text
O
AutoCAD SHX Text
12" CONCRETE MOW BAND - 3000 PSI CONCRETE, MEDIUM BROOM FINISH. RE: DETAIL
AutoCAD SHX Text
K

UP

UP

UP

UP

FILE RM.

BOARD ROOM

ELEVATOR

VESTIBULE

CONFERENCE RM.

STORAGE

STORAGE RM.

SECURE FILE

OFFICE #1

STAIR A

SERVER ROOM

STAIR C

ELEVATOR

LOBBY

ELEV

EFF-2

EFF-1

EFF-2

EFF-1

EFF-2

EFF-1

ENTRY

VESTIBULE

CORRIDOR

TRASH

TV LOUNGE

1 B.R.

EFF-1

EFF-2

MECHANICAL

EL

EC

T.

TELECOM

LAUNDRY

JAN. CLOSET

STAIR B

OFFICE #4

OFFICE #3

OFFICE #2

UNISEX R.R.

UNISEX R.R.

WOMEN'S R.R.

MEN'S R.R.

INTAKE

WORKERS

WO

RK

R

OO

M

CO

RR

ID

OR

CORRIDOR

CO

RR

ID

OR

LOBBY

CO

RR

ID

OR

CORRIDOR

CO

RR

ID

OR

CO

RR

ID

OR

SUITE B

SUITE A

CORRIDOR

IDF

ELEV 1ELEV 2

147-B3

126A-B3

129-B3

127-B3

125-B3

145-B3 146-B3

143-B3

141-B3

124-B3

102-B3

104-B3

106-B3

108-B3

110-B3

112-B3

114-B3

116-B3

118-B3

120-B3

100-B3

101-B3

103-B3

105-B3107-B3

109-B3

111-B3

113-

B3

115-B3

117-B3121-B3

119-B3

149-B3

148-B3

142-B3

135-B3

134-B3

132-B3

131-B3

136-B3

133-

B3

122-

B3

123-B3

130-

B3

128-B3

138-

B3

137-B314

0-B3

150-

B3

151-B3

144-B3

139-B3

126B-B3

152A-B3 152B-B3

4630 N. Loop 1604 WestSan Antonio, Texas 78249210.530.7000 FAX:210.377.1575TBPE Firm Registration No. F-903

FEN

IX E

STAT

ESBU

ILD

ING

S 3

- PH

ASE

IIH

OUS

TON

, TEX

AS

HOUSTON, TEXAS 770041500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202FAX: 713-524-4071www.sc-arch.com

ELEC

TRIC

ALBU

ILD

ING

3 L

EVEL

1

E1.31

UP

CORRIDOR

TRASH

TV LOUNGE

STAIR C

ELEVATOR

LOBBY

ELEV

EFF-2

EFF-1

EFF-2

EFF-1

EFF-2

EFF-1

EFF-2

EFF-1

EFF-2

1 B.R.

STORAGE

EFF-1

EFF-2

EFF-1

EFF-2

EFF-2

EFF-1

1 B.R.

1 B.R.

EFF-1

EFF-2

MECHANICAL

EL

EC

TR

IC

AL

LAUNDRY

STAIR B

JAN. CLOSET

TELECOM

1 B.R.

ELEVATOR

LOBBY

ELEV

ELEV

CO

RR

ID

OR

EFF-1

EFF-2

MECHANICAL

STORAGE

CORRIDOR

EFF-2

STAIR A

200-B3

201-B3

203-B3

202-B3204-B3

206-B3

208-B3

210-B3

212-B3

214-B3

216-B3

218-B3

220-B3

222-B3

224-B3

226-B3

228-B3

230-B3

232-B3

234-B3

236-B3

238-B3

240-B3242-B3

205-B3207-B3

209-B3211-B3

213-

B3

215-B3

217-B3

219-B3

221-B3

223-B3

229-B3

225-B3227-B3

245-

B3

231-B3

233-B3

235-B3

237-B3

243-B3

239-B3

241-B3

4630 N. Loop 1604 WestSan Antonio, Texas 78249210.530.7000 FAX:210.377.1575TBPE Firm Registration No. F-903

FEN

IX E

STAT

ESBU

ILD

ING

S 3

- PH

ASE

IIH

OUS

TON

, TEX

AS

HOUSTON, TEXAS 770041500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202FAX: 713-524-4071www.sc-arch.com

ELEC

TRIC

ALBU

ILD

ING

3 L

EVEL

2

E1.32

UP

CORRIDOR

TRASH

TV LOUNGE

STAIR C

ELEVATOR

LOBBY

ELEV

EFF-2

EFF-1

EFF-2

EFF-1

EFF-2

EFF-1

EFF-2

EFF-1

EFF-2

1 B.R.

STORAGE

EFF-1

EFF-2

EFF-1

EFF-2

EFF-2

EFF-1

1 B.R.

1 B.R.

EFF-1

EFF-2

MECHANICAL

EL

EC

TR

IC

AL

LAUNDRY

STAIR B

JAN. CLOSET

TELECOM

1 B.R.

ELEVATOR

LOBBY

ELEV

ELEV

CO

RR

ID

OR

EFF-1

EFF-2

MECHANICAL

STORAGE

CORRIDOR

EFF-2

STAIR A

300-B3

301-B3

303-B3

302-B3304-B3

306-B3

308-B3

310-B3

312-B3

314-B3

316-B3

318-B3320-B3

322-B3

324-B3

326-B3

328-B3

330-B3

332-B3

334-B3

336-B3

338-B3

340-B3 342-B3

305-B3307-B3

309-B3

311-B3

313-

B3

315-B3

317-B3

319-B3

321-B3

323-B3

329-B3

325-B3327-B3

345-

B3

331-B3

333-B3

335-B3

337-B3

343-B3

339-B3

341-B3

4630 N. Loop 1604 WestSan Antonio, Texas 78249210.530.7000 FAX:210.377.1575TBPE Firm Registration No. F-903

FEN

IX E

STAT

ESBU

ILD

ING

S 3

- PH

ASE

IIH

OUS

TON

, TEX

AS

HOUSTON, TEXAS 770041500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202FAX: 713-524-4071www.sc-arch.com

ELEC

TRIC

ALBU

ILD

ING

3 L

EVEL

3

E1.33

UP

CORRIDOR

TRASH

TV LOUNGE

STAIR C

ELEVATOR

LOBBY

ELEV

EFF-2

EFF-1

EFF-2

EFF-1

EFF-2

EFF-1

EFF-2

EFF-1

EFF-2

1 B.R.

STORAGE

EFF-1

EFF-2

EFF-1

EFF-2

EFF-2

EFF-1

1 B.R.

1 B.R.

EFF-1

EFF-2

MECHANICAL

EL

EC

TR

IC

AL

LAUNDRY

STAIR B

JAN. CLOSET

TELECOM

1 B.R.

ELEVATOR

LOBBY

ELEV

ELEV

CO

RR

ID

OR

EFF-1

EFF-2

MECHANICAL

STORAGE

CORRIDOR

EFF-2

STAIR A

400-B3

401-B3

403-B3

402-B3404-B3

406-B3

408-B3

410-B3

412-B3

414-B3

416-B3

418-B3

420-B3

422-B3

424-B3

426-B3

428-B3

430-B3

432-B3

434-B3

436-B3

438-B3

440-B3 442-B3

405-B3407-B3

409-B3411-B3

413-

B3

415-B3

417-B3

419-B3

421-B3

423-B3

429-B3

425-B3427-B3

445-

B3

431-B3

433-B3

435-B3

437-B3

443-B3

439-B3

441-B3

4630 N. Loop 1604 WestSan Antonio, Texas 78249210.530.7000 FAX:210.377.1575TBPE Firm Registration No. F-903

FEN

IX E

STAT

ESBU

ILD

ING

S 3

- PH

ASE

IIH

OUS

TON

, TEX

AS

HOUSTON, TEXAS 770041500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202FAX: 713-524-4071www.sc-arch.com

ELEC

TRIC

ALBU

ILD

ING

3 L

EVEL

4

E1.34

ELEVATOR

LOBBY

ELEV 1

CEO

OFFICE #6OFFICE #7

OFFICE #8

OFFICE #9

OFFICE #10

OFFICE #11

OFFICE #12

FILE RM.

STAIR A

STAIR B

CONFERENCE RM.

WOMEN'S

MEN'S

OFFICE #13

OFFICE #14

BREAK ROOM

ELEVATOR

LOBBY

STAIR C

ELEV

EFF-2

EFF-1

EFF-2

EFF-1

EFF-2

EFF-1

CORRIDOR

TRASH

TV LOUNGE

1 B.R.

EFF-1

EFF-2

MECHANICAL

EL

EC

T.

TELECOM

LAUNDRY

JAN.

OFFICE #15

RECEPTION

STORAGE RM.

528-B3

554-B3

535-B3

543-B3544-B3

546-B3 545-B3

547-B3

548-B3

551-B3552-B3

541-B3

519-B3

530-B3

534-B3533-B3

538-B3

537-B3

527-B3

504-B3

502-B3

506-B3

508-B3

510-B3

512-B3514-B3

516-B3

518-B3

500-B3

501-B3503-B3

505-B3507-B3

509-B3511-B3

513-

B3

515-B3

517-B3

521-B3

524-B3

531-B3

523-B3

ELEV 2

555-B3

CORRIDOR

522-B3

CORRIDOR

539-B3

CO

RR

ID

OR

526-

B3

WORK POOL

SOUTH

525-B3

CO

RR

ID

OR

536-

B3

CO

RR

ID

OR

549-

B3

CO

RR

ID

OR

542-

B3

CORRIDOR

550-B3

WORK POOL

NORTH

553-B3

WORK POOL

CENTRAL

540-B3

IDF

520-B3

4630 N. Loop 1604 WestSan Antonio, Texas 78249210.530.7000 FAX:210.377.1575TBPE Firm Registration No. F-903

FEN

IX E

STAT

ESBU

ILD

ING

S 3

- PH

ASE

IIH

OUS

TON

, TEX

AS

HOUSTON, TEXAS 770041500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202FAX: 713-524-4071www.sc-arch.com

ELEC

TRIC

ALBU

ILD

ING

3 L

EVEL

5

E1.35

ELECT.

TELECOM

113-B3

115-B3ELECT.

TELECOM

513-B3

515-B3

4630 N. Loop 1604 WestSan Antonio, Texas 78249210.530.7000 FAX:210.377.1575TBPE Firm Registration No. F-903

FEN

IX E

STAT

ESBU

ILD

ING

S 3

- PH

ASE

IIH

OUS

TON

, TEX

AS

HOUSTON, TEXAS 770041500 MCGOWEN ST. SUITE 200

PHONE: 713-524-4202FAX: 713-524-4071www.sc-arch.com

ELEC

TRIC

AL B

UILD

ING

3EN

LARG

ED P

LAN

S

E3.00