ASSEMBLY AND INSTALLATION INSTRUCTIONS NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements. 2. READ AND SAVE THESE INSTRUCTIONS. H0138 Hardware Package (included): WARNING: TO AVOID RISK OF ELECTRICAL SHOCK, BE SURE TO SHUT OFF POWER WHILE INSTALLING OR SERVICING THIS FIXTURE. 150119 Green Grounding Screw (H) Wire Nut (I) Canopy (A) Loop Lock (G) Chain (J) Hex Nut (D) Washer (C) Glass Drop d 1PC Glass Drop a 8PCS Glass Drop b 12PCS Nipple-a (E) Nipple-b (F) Top Loop (B) Collar (K) Clamp (L) Connector (M) Glass Drop c 12PCS Clamp(L) Set Screw Safety Steel Cord Outlet Box Nipple-b(F) Fixture Wire Fixture Grounding Wire Nipple-a(E)) Connector(M) Set Screw Ceiling Structura Member House Supply And Grounding Wires Wire Nut 3/4" Hole Big Metal Pad(N) Lock Nut(P) Top Loop(B) Loop Lock(G) Loop Lock(G) Loop Top Decorative Cup Bottom Decorative Cup Chain(J) Canopy(A) Collar(J) Flat Pad(O) Bulb Type A Max.100W (not included) Socket Fixer Glass Shade Glass Drop a Glass Drop c Glass Drop b Glass Drop b Glass Drop c Glass Drop d Socket Glass Bracket Threaded Pipe-2 Finial Fixture Bottom Cover Slot Hex Nut Washer Coupling Connector Top Cover Slot Metal Pad Hex Nut Threaded Pipe-1 Coupling Upper Arm Middle Arm Socket Ring Spacer Hex Nut Big Metal Pad(N) Flat Pad(O) Lock Nut (P) Set Screw Clamp Knot Safety Steel Cord Fig.2 Nipple(-a) Nipple(-b) Set Screw Connector 1/2" 1/2" Fig.1

Upload: others

Post on 12-Mar-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: H0138 WARNING: TO AVOID RISK OF ELECTRICAL SHOCK, BE …pdf.lowes.com/installationguides/884656732924_install.pdf · POWER WHILE INSTALLING OR SERVICING THIS FIXTURE. 150119 Green

ASSEMBLY AND INSTALLATION INSTRUCTIONS

NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements. 2. READ AND SAVE THESE INSTRUCTIONS.

H0138

Hardware Package (included):

WARNING: TO AVOID RISK OF ELECTRICAL SHOCK, BE SURE TO SHUT OFFPOWER WHILE INSTALLING OR SERVICING THIS FIXTURE.

150119

Green Grounding Screw (H)

Wire Nut (I)Canopy (A) Loop Lock (G)

Chain (J)

Hex Nut (D)Washer (C)

Glass Drop d1PC

Glass Drop a8PCS

Glass Drop b12PCS

Nipple-a (E) Nipple-b (F)Top Loop (B)

Collar (K) Clamp (L) Connector (M)

Glass Drop c12PCS

Clamp(L)

Set ScrewSafety Steel Cord

Outlet Box

Nipple-b(F)Fixture Wire

Fixture Grounding Wire

Nipple-a(E))

Connector(M)

Set Screw

Ceiling Structura Member

House Supply And Grounding Wires

Wire Nut

3/4" Hole Big Metal Pad(N)Lock Nut(P)

Top Loop(B)

Loop Lock(G)

Loop Lock(G)

Loop

Top Decorative Cup

Bottom Decorative Cup

Chain(J)

Canopy(A)

Collar(J)

Flat Pad(O)

Bulb Type A Max.100W (not included)

Socket Fixer

Glass Shade

Glass Drop a

Glass Drop c

Glass Drop b

Glass Drop b

Glass Drop c

Glass Drop d

SocketGlass Bracket

Threaded Pipe-2

Finial

Fixture

Bottom CoverSlot

Hex NutWasher

CouplingConnector

Top CoverSlot

MetalPad

Hex NutThreaded Pipe-1Coupling

Upper Arm

Middle Arm

Socket RingSpacer

Hex Nut

Big Metal Pad(N) Flat Pad(O) Lock Nut (P)

Set ScrewClamp

Knot

Safety SteelCord

Fig.2

Nipple(-a)

Nipple(-b)

Set Screw

Connector1/2"

1/2"

Fig.1

Tom
Typewriter
5069GS
Tom
Typewriter
5071GS
Tom
Typewriter
5070GS
Tom
Typewriter
5073GS
Page 2: H0138 WARNING: TO AVOID RISK OF ELECTRICAL SHOCK, BE …pdf.lowes.com/installationguides/884656732924_install.pdf · POWER WHILE INSTALLING OR SERVICING THIS FIXTURE. 150119 Green

150119

1. This heavy fixture requires a means of support independent of the outlet box. Remove the knockout slug from the inside top center of the outlet box, and then drill a 3/4 inch diameter hole through the ceiling structural member. The fixture will be installed directly onto the ceiling structural member. Before starting assembly, it is important to make sure that the ceiling structural member can at least support four times weight of the fixture. We recommend the consultation of a qualified electrician due to the complexity of this installation.

2. Adjust the arms of the fixture according to the drawing of the package. Important: a. The arms of each tier (upper, middle) should be positioned with equal distances between them. b. The arms should be fixed securely.

3. Attach the threaded pipe-1 to coupling, secure it with hex nut. NOTE:Depth of threaded pipe-1 may need to be adjusted to properly fit top cover, top decorative cup and loop. 4. Slip the top cover through the threaded pipe-1 to fixture and the metal pad engages into the slots of top cover.

5. Slip the top decorative cup to top cover, secure it with hex nut. Then screw the loop to threaded pipe-1. Thread fixture wires through threaded pipe-1, top cover, top decorative cup, hex nut and threaded end of loop first.

6. Attach the threaded pipe-2 to coupling, secure it with a washer and hex nut. NOTE:Depth of threaded pipe-2 may need to be adjusted to properly fit bottom cover, bottom decorative cup and finial.

7. Slip the bottom cover through the threaded pipe-2 to fixture and the connectors engage into the slots of bottom cover.

8. Slip the bottom decorative cup to bottom cover, secure it with hex nut. Then screw the finial to threaded pipe-2.

9. Install the glass drops(a,b,c,d) as shown in diagram.

10. Connect the chain: - Determine length of chain needed to achieve desired fixture height. (To remove excess chain section, use plier to bend link open.) - Weave the fixture wires through the chain, collar and canopy.

11. Secure the top loop to the nipple-b pipe.

12. Screw the connector to other end of nipple-b about 1/2 inch, and then secure it with a set screw at side of connector. (See Fig.1)

13. Thread the fixture wires and the fixture grounding wire through the top loop, nipple-b and pull them out from bigger hole at side of connector.

14. Screw one end of nipple-a into the other end of the connector about 1/2 inch, and then secure it with a set screw from the side of the connector. (See Fig.1)

15. Thread the safety steel cord through the collar, canopy, top loop, nipple-b, connector and nipple-a.

16. Connect one end of the chain to the loop using a loop lock.

17. Connect the other end of the chain to the top loop using the other loop lock.

18. This step requires three people at least to proceed. Two people hold the fixture, the other one inserts the safety steel cord, and nipple-a through the drilled hole of the ceiling structural member, and then secures it with a big metal pad and lock nut.

19. Thread the safety steel cord through the flat pad, and then through one hole of the clamp. Make a knot, and then pull it out from the other hole of the clamp. Pull the cord straightly and attach the flat pad toward the top end of nipple-a, and then attach the clamp toward the flat pad. Tighten the safety steel cord with two set screws from two ends of the clamp. (See Fig.2) Note: The safety steel cord provides a back up system of the installation fixture. It's essential that the safety steel cord is properly installed.

Turn off the power at fuse or circuit box.

Installation Steps

Page 3: H0138 WARNING: TO AVOID RISK OF ELECTRICAL SHOCK, BE …pdf.lowes.com/installationguides/884656732924_install.pdf · POWER WHILE INSTALLING OR SERVICING THIS FIXTURE. 150119 Green

150119

Turn on the power at fuse or circuit box.

The following parts are available for re-order if damaged or missing.

Spare Parts List:

Assembly Kit 5298MM (1 SET)

Glass Shade9700AB(12PCS)

A

B

Glass Drop d5073GS(1PC)

Glass Drop a5069GS(8PCS) Glass Drop b

5071GS(12PCS) Glass Drop c5070GS(12PCS)

20. Pull out the source wires from the outlet box. Make wire connections using wire nuts as follows: ---Connect the smooth-coated wire (marked) from the fixture to the black wire from the power source. ---Connect the ribbed-coated wire (unmarked) from the fixture to the white wire from the power source. ---Connect the fixture grounding wire to the house grounding wire with a wire nut. Carefully put the wires back into the outlet box.

21. Attach the canopy to the ceiling: insert the top loop through hole, then secure by tightening collar.

22. Attach the glass shades to the glass brackets, secure them with the spacers and socket rings, using supplied socket fixer

23. Install bulbs (not included). See relamping label at socket area or packaging for maximum allowed wattage.

Green Grounding Screw (H)

Wire Nut (I)

Canopy (A)

Loop Lock (G)

Chain (J)

Hex Nut (D)Washer (C)

Nipple-a (E) Nipple-b (F)

Top Loop (B)

Collar (K) Clamp (L)

Connector (M) Big Metal Pad(N) Flat Pad(O) Lock Nut (P)

A: 45-1/2"

B:53"