Green HVAC NABERS + JV3 Ania Hampton, B.Eng(Mech), M.AIRAH Director

Upload: others

Post on 17-Mar-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Green HVAC NABERS + JV3 · JV3 modelling method •Reference building complies with DTS requirements •Protocol specifies loads and profiles •Reference and proposed building must

Green HVACNABERS + JV3

Ania Hampton, B.Eng(Mech), M.AIRAHDirector

Page 2: Green HVAC NABERS + JV3 · JV3 modelling method •Reference building complies with DTS requirements •Protocol specifies loads and profiles •Reference and proposed building must

NABERS

Video courtesy NABERS

Page 3: Green HVAC NABERS + JV3 · JV3 modelling method •Reference building complies with DTS requirements •Protocol specifies loads and profiles •Reference and proposed building must

NABERS

Technology neutral

Fair comparison

Based on metered

performance

Image courtesy NABERS

Page 4: Green HVAC NABERS + JV3 · JV3 modelling method •Reference building complies with DTS requirements •Protocol specifies loads and profiles •Reference and proposed building must

1 STAR

POOR

2 STARS

BELOWAVERAGE

3 STARS

AVERAGE

4 STARS

GOOD5 STARS

EXCELLENT

6 STARS

MARKETLEADING

Image courtesy NABERS

Page 5: Green HVAC NABERS + JV3 · JV3 modelling method •Reference building complies with DTS requirements •Protocol specifies loads and profiles •Reference and proposed building must

Shopping centres

Hotels Data centres

Offices

Image courtesy NABERS

Page 6: Green HVAC NABERS + JV3 · JV3 modelling method •Reference building complies with DTS requirements •Protocol specifies loads and profiles •Reference and proposed building must

NABERS + HVAC

Energy

• Energy consumption of HVAC system

• Co/tri-generation

Water

• Cooling towers

• Evaporative cooling

• Fire systems

IEQ• Thermal

comfort: temperature, humidity + air speed

• Ventilation• Pollutants• Acoustics• Maintenance

and cleaning of air systems

Page 7: Green HVAC NABERS + JV3 · JV3 modelling method •Reference building complies with DTS requirements •Protocol specifies loads and profiles •Reference and proposed building must

Who owns what (HVAC)

Base building

• Main HVAC system

• Central plant (chillers, boilers, cooling towers, pumps, AHUs etc)

• Supplementary chilled or condenser water circuit (pumps, cooling tower etc)

• Measured IEQ parameters (T°C, %RH, air m/s, pollutants ppm, sound dB etc)

Tenant

• Supplementary HVAC e.g. comms rooms, meeting rooms, individual offices. Based on specific tenant requirement.

• Occupant satisfaction survey for IEQ (tell me, how do you feel)

Page 8: Green HVAC NABERS + JV3 · JV3 modelling method •Reference building complies with DTS requirements •Protocol specifies loads and profiles •Reference and proposed building must

Commitment Agreements

• Allows owner to market NABERS performance prior to formal rating

• Requires energy modelling in accordance with strict protocols

• Independent design review

• “What if” scenarios

Page 9: Green HVAC NABERS + JV3 · JV3 modelling method •Reference building complies with DTS requirements •Protocol specifies loads and profiles •Reference and proposed building must

Designing for NABERS

• Fit for purpose

• Size for purpose

• Simplicity

• Controls

• Metering

• Commissioning

• Designing for people comes first

Page 10: Green HVAC NABERS + JV3 · JV3 modelling method •Reference building complies with DTS requirements •Protocol specifies loads and profiles •Reference and proposed building must

NCC Section J

Mandatory compliance

Deemed-to-Satisfy (DTS) provisions for:

• J1 – Insulation

• J2 – Glazing

• J3 – Sealing

• J5 – HVAC

• J6 – Lighting

• J8 – Monitoring and Maintenance

Page 11: Green HVAC NABERS + JV3 · JV3 modelling method •Reference building complies with DTS requirements •Protocol specifies loads and profiles •Reference and proposed building must

JV3

• “Alternative solution” used instead of Deemed-to-Satisfy (DTS) e.g:

– Too much glazing

– Insufficient space for economy cycle in retrofit

• Looks at building as a whole

• Compares energy consumption of proposed building to one which complies with DTS

Page 12: Green HVAC NABERS + JV3 · JV3 modelling method •Reference building complies with DTS requirements •Protocol specifies loads and profiles •Reference and proposed building must

Modelling for JV3

Page 13: Green HVAC NABERS + JV3 · JV3 modelling method •Reference building complies with DTS requirements •Protocol specifies loads and profiles •Reference and proposed building must

JV3 modelling method

• Reference building complies with DTS requirements

• Protocol specifies loads and profiles

• Reference and proposed building must be identical w.r.t. façade, layout and HVAC system

• Specific parameters change based on DTS provisions (e.g. R Value, U Value/SHGC, O/A rates, pump and fan powers, lighting energy)