GRANT CONDENSING OIL BOILER RANGE Internal and external oil-fired condensing boilers with outputs from 12kW to 70kW

Upload: doantram

Post on 28-Jul-2018

219 views

Category:

Documents


1 download

TRANSCRIPT

GRANT CONDENSINGOIL BOILERRANGEInternal and external oil-fired

condensing boilers with outputs from 12kW to 70kW

02

Grant Vortex Condensing Indoor Range

Dimensions (mm)Grant Vortex 15-21 Kitchen/Utility

Grant Vortex 15-26 Kitchen/Utility and System

Grant Vortex 26-36 and 36-46 Kitchen/Utility and System

Grant Vortex 46-58 and 58-70 Kitchen/Utility

620

TRAP EXTERNALDRAIN EXITLEFT HAND

TRAP INTERNALDRAIN EXITLEFT HANDHIGH LEVEL

TRAP INTERNALDRAIN EXITLEFT HANDLOW LEVEL

101

370

831

731

1024

170

210

786781

210

594

410

TRAP EXTERNALDRAIN EXITLEFT HAND

TRAP INTERNALDRAIN EXITLEFT HANDHIGH LEVEL

TRAP INTERNALDRAIN EXITLEFT HANDLOW LEVEL

L/H FLOWL/H RETURN

86

566

719

556

441

61

60

TRAP EXTERNALDRAIN EXITLEFT HAND

61

TRAP INTERNALDRAIN EXITLEFT HANDHIGH LEVEL

TRAP INTERNALDRAIN EXITLEFT HANDLOW LEVEL 82

86

603

445

860

712

83

624

177

88

605

TRAP EXTERNALDRAIN EXITLEFT HAND

TRAP INTERNAL DRAIN EXIT LEFT HANDLOW LEVEL

TRAP INTERNAL DRAIN EXIT LEFT HANDHIGH LEVEL

603

Overheat thermostat

Boiler thermostat

Internalcondensate

trap (withexternal option)

Boiler on/off switch

Grant Vortex Kitchen/Utility Models

Model shown: VTX15/21 (front view)

Riello RDB burner with plug &socket connection

VTX15/21 only

348mm wide

Grant Vortex Combi Internal 26e

Grant Vortex Combi Internal 36e

03057 9120089 (ROI) | 0800 2794796 (NI) | www.grantengineering.ie

Overheat thermostat

Boiler thermostat

Boiler on/off switch

System pressure gauge

Internal condensate trap (with external option)

Grant Vortex Kitchen/UtilitySealed System Models

Model shown: VTXS15/26 (front view)

Riello RDB burner with plug & socket connection

Technical Specifications

Model Kitchen/Utility Models Kitchen/Utility System Models

15-21 15-26 26-36 36-46 46-58 58-70 15-26S 26-36S 36-46S

Output kW 15 to 21 15 to 26 26 to 36 36 to 46 46 to 58 58 to 70 15 to 26 26 to 36 36 to 46

Output Btu/h 50-70,000 50-90,000 90-123,000 123-157,000 157-200,000 200-240,000 50-90,000 90-123,000 123-157,000

Flow connection 22mm 22mm 28mm 28mm

Efficiency 93% 95% 97% 92.6% 94.1% 93.6% 95% 97% 92.6%

11/4” BSP 11/4” BSP 22mm 28mm 28mm

Return connection 22mm 22mm 28mm 28mm 11/4” BSP 11/4” BSP 22mm 28mm 28mm

Cold water in (system kit) n/a n/a n/a n/a n/a n/a 15mm 15mm 15mm

Pressure relief (system kit) n/a n/a n/a n/a n/a n/a 15mm 15mm 15mm

Weight (dry) 97kg 130kg 144kg 150kg 268kg 282kg 138kg 167kg 168kg

Condensate pipe 21.5mm OD plastic overflow pipe

Note 1: The boiler flow and return connections exit the casing on the left or right hand side. Note 2: Grant Vortex Kitchen/Utility, Grant Vortex internal and external condensing Combi boilers are suitable for fully pumped systems only.Note 3: SAP 2005 annual efficiencies.Note 4: For Combi hot water performance see back page. *System models only

Vortex CombiInternal Models26 36

26 36

90,000 123,000

92.2% 94.2%

22mm 28mm

22mm 28mm

15mm 22mm

Hot water out n/a n/a n/a n/a n/a n/a n/a n/a n/a 15mm 22mm

15mm 15mm

177kg 200kg

24 litre expansion vessel

Boiler on/off switch

Neon diagnostic indicators Electronic

boiler thermostat

Nickel plated pipes

35 Plate heat exchanger

Flexible filling loop

Primary store drain cock

Front service access

Thermostatic blending valve

Heating and hot water selector switches

System pressure gauge

Overheat thermostat

Grant Vortex Combi Internal Models

Riello RDB burner with plug & socket connection

Model shown: VTXCOMBI26 (front view)

Internal condensate

trap (with external option) High efficiency pump

(hot water circuit)

04

Grant Vortex External Range

Dimensions (mm)Grant Vortex External 15-21

Grant Vortex External 15-26 26-36 36-46

385

879

122 122

943

734248

879

788

637

517

307

187

112

124

Grant Vortex External 46-58 58-70

Grant Vortex Combi External 26e and 36e

1154

945233

587

1154 12

40

191 191

1240

1154

1000

816

418

179

68

05057 9120089 (ROI) | 0800 2794796 (NI) | www.grantengineering.ie

Control panel

Optional side flue exit

Optional pipe entry points

Boiler on/off switch

Test switch Boiler thermostat

Overheat thermostat

Grant Vortex External Modules

Model shown: VTXOM15/26 (front view)

Frost stat set to 2°C (factory fitted inside control panel - not shown)

Condensate trap (factory-fitted in rear of casing - not shown)

Riello RDB burner with plug & socket connection

Electronic boiler thermostat

Built-in system pressure gauge

24 litre expansion vessel

Flexible filling loop

Nickel plated pipes

High efficiency pump (hot water circuit)

Thermostatic blending valve

Neon diagnostic indicators

Service switch

Internal condensate trap (factory-fitted in rear of casing) not shown

Boiler on/off switch

Electrical isolation plug

Overheat thermostat

Grant Vortex Combi External Modules

Model shown: VTXOMCOMBI26 (front view)

Riello RDB burner with plug & socket connection

Technical Specifications - Boiler Connections

Model Vortex External Modules

Output kW

Output Btu/h

Flow connection

Return connection

Cold water in (system kit & combi)

Hot water out (combi)

Pressure relief (system kit & combi)

Weight (dry)

Condensate pipe 21.5mm OD plastic overflow pipe

Note 1: All boiler connections can be positioned to the left or right of the appliance. Note 2: Grant Vortex Condensing modules are suitable for fully pumped systems only. Note 3: For Combi hot water performance, see page 12.

26

26

90,000

22mm

22mm

15mm

15mm

15mm

206kg

36

36

123,000

28mm

28mm

22mm

22mm

15mm

225kg

58-70

58 to 70

200-240,000

11/4” BSP

11/4” BSP

15mm

n/a

15mm

288kg

46-58

46 to 58

157-200,000

11/4” BSP

11/4” BSP

15mm

n/a

15mm

274kg

36-46

36 to 46

123-157,000

28mm

28mm

15mm

n/a

15mm

168kg

26-36

26 to 36

90-123,000

28mm

28mm

15mm

n/a

15mm

162kg

15-26

15 to 26

50-90,000

22mm

22mm

15mm

n/a

15mm

143kg

15-21

15 to 21

50-70,000

22mm

Efficiency 92.6% 94.1% 93.6% 92.2% 94.2%97%95%93%

22mm

15mm

n/a

15mm

109kg

Galvanisedsteel casing

Galvanisedsteel casing

*Combi models onlyNote 4: SAP 2005 annual efficiencies.

Vortex Combi External Modules

06

Grant Vortex Wall Hung Range

Dimensions (mm)Grant Vortex Wall Hung Internal 12-16, 16-21

580

321.

840

112

321.6

221

112

Grant Vortex Wall Hung External 12-16, 16-21

832.5

836.5

634.4

621

36.6

832.5

349.8 629621

Multi-directional flue (Factory-fitted)

Pressure relief valve

Automatic air vent

Burner

Overheat thermostat

Removable control panel

Internal condensate trap

Drain cock

Boiler on/off switch

Service switch

System pressure gauge

Boiler thermostat

Technical Specifications

Model Internal Models

External Modules

12-16 16-21 12-16 16-21

Output kW 12 to 16 16 to 21 12 to 16 16 to 21

Output Btu/h 40-55,000 55-70,000 40-55,000 55-70,000

Flow connection 22mm 22mm 22mm 22mm

Efficiency 94.9% 93.8% 94.9% 93.8%

Return connection 22mm 22mm 22mm 22mm

Cold water in n/a n/a n/a n/a

Pressure relief n/a n/a n/a n/a

Weight (dry) 86kg 86kg 93kg 93kg

Condensate pipe 21.5mm OD plastic overflow pipe

Note 1: The boiler flow connection exits the casing on the top or bottom. Note 2: The return connection is located on the right and the condensate drain on the left.

Grant Vortex Wall Hung Internal/Internal System Models

Grant Vortex Wall Hung External/External System Models

Multi-directional flue options (not supplied) see EZ flue kits

Remote lock-out indicator

Pressure relief valve

Automatic air vent

BurnerOverheat thermostat

Removable control panel

High efficiency Pump

Internal condensate trap

Expansion vessel

Drain cock

Boiler on/off switch

Boiler thermostatSystem pressure gauge

Model shown: VTXSWH12/16 (front view)

Model shown: VTXSOMWH12/16 (front view)

High efficiency Pump

Frost stat set to 2°C (factory fitted inside control panel - not shown)

*System models only

Note 3: SAP 2005 annual efficiencies.

Internal System Models

12-16 16-21

12 to 16 16 to 21

40-55,000 55-70,000

22mm 22mm

94.9% 93.8%

22mm 22mm

15mm 15mm

15mm 15mm

98kg 98kg

External System Modules

12-16 16-21

12 to 16 16 to 21

40-55,000 55-70,000

22mm 22mm

94.9% 93.8%

22mm 22mm

15mm 15mm

15mm 15mm

97kg 97kg

07057 9120089 (ROI) | 0800 2794796 (NI) | www.grantengineering.ie

08

Grant Vortex Boiler House Range

Technical Specifications - Boiler Connections

Model Vortex Boiler House Models

Output kW

Output Btu/h

Flow connection

Return connection

Cold water in (system kit)

Pressure relief (system kit)

Weight (dry)

Condensate pipe 21.5mm OD plastic overflow pipe

Note 1: The boiler flow and return connections exit the casing on the left or right hand side. Note 2: Grant Vortex Boiler House boilers are suitable for fully pumped systems only.

*System models only

58-70

58 to 70

200-240,000

11/4” BSP

11/4” BSP

n/a

n/a

301g

46-58

46 to 58

157-200,000

11/4” BSP

11/4” BSP

n/a

n/a

257kg

36-46

36 to 46

123-157,000

28mm

1” BSP

n/a

n/a

145kg

15-26

15 to 26

50-90,000

28mm

1” BSP

n/a

n/a

125kg

26-36

26 to 36

90-123,000

Efficiency 94.1%92.6%97% 93.6%95%

28mm

1” BSP

n/a

n/a

143kg

Note 3: SAP 2005 annual efficiencies.

Top flue exit

Heating flow (under blanking plate)

Stainless steelcondensingheat exchanger

Galvanisedand powdercoated

Condensate trap(Not shown)

Dual stat - comes fitted on 46-58 and 58-70 models

Heating return (under blanking plate)

Grant Vortex Boiler House Models

Model shown:

VTXBH46/58 (front view)

Riello RDB burner with plug & socket connection

Grant Vortex Boiler House 26-36 and 36-46

Grant Vortex Boiler House 46-58 and 58-70

460 600

705

560

191

Flow

Stat

540 868

1022

835

285

Flow

Stat

Dimensions (mm)

431

431 600

714

Grant Vortex Boiler House 15-26

Dimensions (mm)

Grant Euroflame 15-21 and 21-26Utility and System

860

860

712

624

177

88

445

605

TRAP EXTERNALDRAIN EXITLEFT HAND

TRAP INTERNAL DRAIN EXIT LEFT HANDLOW LEVEL

TRAP INTERNAL DRAIN EXIT LEFT HANDHIGH LEVEL

430

Technical Specifications

Model

Output kW

Output Btu/h

Flow connection

Return connection

Cold water in (system kit)

Pressure relief (system kit)

Weight (dry)

Condensate pipe 21.5mm OD plastic overflow pipe

Note 1: The boiler flow and return connections exit the casing on the left or right hand side.

Note 2: Grant Euroflame Utility boilers are suitable for fully pumped systems only.

Euroflame Utility Models

15-21

15 to 21

50-70,000

22mm

22mm

n/a

n/a

97kg

21-26

21 to 26

70-90,000

22mm

22mm

n/a

n/a

97kg

Euroflame Utility System ModelsEuroflame Utility System Models

26-35

26 to 35

90-120,000

22mm

22mm

n/a

n/a

127kg

15-21S

15 to 21

50-70,000

22mm

22mm

15mm

15mm

123kg

21-26S

21 to 26

70-90,000

22mm

22mm

15mm

15mm

123kg

26-35S

26 to 35

90-120,000

Efficiency 93% 92.4% 92.1% 93% 92.4% 92.1%

22mm

22mm

15mm

15mm

138kg

Note 3: SAP 2005 annual efficiencies.

Euroflame Utility System Models

Grant Euroflame Kitchen/Utility System Models

Boiler on/off switch

Boiler thermostat

Overheat thermostat

Internal condensate trap (with externaloption)

Front service access door

Multi-directional heating return (not shown)

Multi-directional heating flow (not shown)

12 Litre expansion vessel

High efficiency pump

Model shown: EUROFLAME15/21 (front view)

Riello RDB burner with plug & socket connection

Grant Euroflame Kitchen/UtilityModels

Model shown: EUROFLAME15/21 (front view)

Boiler on/off switch

Boiler thermostat

Overheat thermostat

Internal condensate trap (with externaloption)

Front service access door

Multi-directional heating return (not shown)

Riello RDB burner with plug & socket connection

Multi-directional heating flow (not shown)

CondensateRemovalThe condensate trap is nowfactory fitted within the whitecase on Grant EuroflameUtility boilers, but can also bepositioned externally ifpreferred.

FlueingUtility models are compatiblewith all of Grant’s EZ-Fit flueoptions and capable of beingflued from the top, rear, left or right hand sides of theappliance.

Sealed SystemModelsGrant Euroflame Utility boilersare also available in sealedsystem versions. Theseinclude a factory fittedexpansion vessel, filling loop,pressure gauge, automatic air vent, pressure relief valveand high efficiency circulatingpump, enabling boilers to beinstalled without the need fora feed and expansion tank in the loft.

Grant Euroflame Kitchen/Utility Range

09057 9120089 (ROI) | 0800 2794796 (NI) | www.grantengineering.ie

Grant Euroflame 26-35Utility and System

719

587

441

TRAP EXTERNALDRAIN EXITLEFT HAND

TRAP INTERNALDRAIN EXITLEFT HANDHIGH LEVEL

TRAP INTERNALDRAIN EXITLEFT HANDLOW LEVEL 82

86

603

Grant Euroflame External Range

Dimensions (mm)Grant Euroflame External and External System 15-21, 21-26, 26-35

Optional pipe entry points

Condensate trap

(factory-fitted in rear of casing - not shown)

Model shown: EUROFLAME MOD 15-21 (front view)

Riello RDB burner with plug & socket connection

Grant EuroflameExternal Modules

Optional side or rear flue exits

Boiler thermostat

Overheat thermostat

Technical Specifications

Model Euroflame External modules

15-21 21-26 26-35

Output kW 15 to 21 21 to 26 26 to 35

Output Btu/h 50-70,000 70-90,000 90-120,000

Flow connection 22mm

Efficiency 93% 92.4% 92.1%

Return connection 22mm

22mm

22mm

22mm

22mm

Cold water in (system kit) n/a n/a n/a

Pressure relief (system kit) n/a n/a n/a

Weight (dry) 113kg 113kg 142kg

Condensate pipe 21.5mm OD plastic overflow pipe

Note 1: All boiler connections can be positioned to the left or right of the appliance.

Note 2: Grant Euroflame External modules are suitable for fully pumped systems only.Note 3: SAP 2005 annual efficiencies.

*System models only

10

Grant Euroflame Boiler House Range

Top flue exit

Heating flow (under blanking plate)

Stainless steelcondensingheat exchanger

Galvanisedand powdercoated

Condensate trap(Not shown)

Dual stat

Heating return (under blanking plate)

Grant Euroflame Boiler House Models

Riello RDB burner with plug & socket connection

Technical Specifications

Model Euroflame Boiler House modules

15-21 21-26 26-35

Output kW 15 to 21 21 to 26 26 to 35

Output Btu/h 50-70,000 70-90,000 90-120,000

Flow connection 1”GB

Efficiency 93% 92.4% 92.1%

Return connection 1”GB

1”GB

1”GB

1”GB

1”GB

Cold water in (system kit) n/a n/a n/a

Pressure relief (system kit) n/a n/a n/a

Weight (dry) 113kg 113kg 142kg

Condensate pipe 21.5mm OD plastic overflow pipe

Note 1: All boiler connections can be positioned to the left or right of the appliance.

Note 2: Grant Euroflame Boiler House modules are suitable for fully pumped systems only.Note 3: SAP 2005 annual efficiencies.

435 600

715

Grant Euroflame Boiler House15-21, 15-26, 26-35

11057 9120089 (ROI) | 0800 2794796 (NI) | www.grantengineering.ie

435

Dimensions (mm)

GRANT ENGINEERING IRELANDCrinkle, Birr, Co. Offaly, IrelandT: (057) 9120089 F: (057) 9121060 E: [email protected] www.grantengineering.ie

NORTHERN IRELANDUnit 117, 21 Botanic AvenueBelfast BT7 1JJ, Northern IrelandFREEPHONE : 0800 2794796E: [email protected]

BR

OS

NA

PR

ES

SC

RE

ATIV

E D

ES

IGN

& P

RIN

T •

RE

V N

OV

16

GuaranteesThe unique heat exchanger on the Grant Condensing Boiler iscovered by a 5-year guarantee. All other component parts ofthe boiler are guaranteed for 2 years from the date of purchase(excluding consumable items, labour, handling or shipping),subject to being installed in accordance with the manufacturer’sinstructions. On completion of the installation all GrantCondensing Boilers must be commissioned and the boilerpassport returned to Grant Engineering for registration.

After sales serviceFor peace of mind, all Grant Condensing Boilers are backed bya national network of service engineers.

In the unlikely event of a problem occurring, your installershould telephone our customer service department on: (057) 9120089. All images for illustration purposes only.

Grant Vortex Mag-One Magnetic FilterThe Mag-One (Part code: VM01) providesinnovative protection for your Grant Vortex oil-fired boiler and central heating system up to 36kW. Using a simple to install, triple actionfiltration design, the Mag-One filters magnetiteand non-ferrous debris from central heatingsystems with a 12000 gauss neodymiummagnet.

This brochure is accurate at the time of printing but as Grant Engineering has apolicy of continual improvement it may be superseded. We reserve the right toamend specifications without prior notice. The statutory rights of the consumerare not affected.

All products manufactured under I.S. EN ISO 9001.

™THE GRANT ‘EZ-FIT FLUE’ SYSTEM is a Trade Mark of Grant Engineering Limited.®Grant Aerona, Grant Spira, Grant Vecta, Grant Vortex, Grant Solar, Grant Aurora,Grant Sahara, Grant CombiSOL, Grant WinterSOL, Grant MonoWave, Grant DuoWave,Grant ThermaWave, Euroflame and Multi Pass are registered trade marks of GrantEngineering Limited. The contents of this leaflet are fully protected by copyright andnothing may be reproduced without permission from Grant Engineering.

Flue SystemsAll Grant Vortex oil-fired boilers are supplied for connection toeither a ‘stainless steel’ conventional flue, or one of Grant’sEZ-Fit flue options. The flue systems are available as low level,high level or vertical kits, for internal and external applications,and even as unique EZ-Flexi packs designed to enablecondensing boilers to utilise an existing chimney. All our EZ-Fitflues carry the CE mark of approval, are adaptable to anyinstallation, and deliver excellent value for money.

Typical Hot Water Performance26kW Combi** 17 litres per minute at an average temperature of 50°C.Recovery time 4 minutes approx. Based upon 100 litre draw off.

36kW Combi** 20 litres per minute at an average temperature of50°C. Recovery time 3 minutes approx. Based upon 100 litre draw off.

Mains Water PressureMinimum: 2.5bar (36psi). Maximum: 8bar (115psi).** Hot water flow rate is dependent on mains pressure available.Figures based upon an incoming mains water temperature of 10°C.

FuelAll burners are supplied factory set a the stated output for useon standard grade Kerosene – Class C2. Grant CondensingBoilers are not suitable for use with Class D gas oil.

InstallationInstallation must comply with the current Building Regulations.Comprehensive technical information can be found in theinstallation manual, suppllied with every boiler.