NEW ZEALAND LTD.0800 650 445
SkyProduct Management
Name DateDrawn byChecked byDrawing No.
Jan. 08Jan. 08
VELUX Roof Window type GGL + EDW flashing installed in profiledmetal sheets
This drawing is an instrument of service and is provided for informational use only. 2006 VELUX GROUP VELUX is a registered trademark
60150 m
m
25 mm
80 mm
20 mm
3060 mm
1.
2.
2.
Insulation
Installation batten
VELUX Roof Window type GGL
Installation batten
Lining
EDW flashing
Building paper
RafterInsulation
Ventilation gap
EDW Flashing
ELEVATIONS
SECTION AA
SECTION BB
BB
AA
VELUX Skylight installed in to existing metal roofing.
1. The metal sheet is cut to allow for the flashing apron. The cut must stop on top of a profile (min 270 mm from the side frame)
2. The fillet piece is placed so it fits the cut (can be fixed to the existing metal sheets with rivots) (Shape the fillet piece from the cutout sheets of the skylight)
3. 3.
1. 1.
VELUX Skylight installed in new metal roofing.
1. The sheets are fitted 6080 mm from the bottom frame
2. The flashing is mounted
3. Fit the metal sheets
Kindly be aware that all measurements on this drawing must be checkeddirectly on the building site. With this drawing, VELUX provides only an ideaand consequently has no influence on the quality of the actual installationperformed on the roof.
GGL
EDW
PROFILEDMETAL SHEETS