ge digital energy multilin
DESCRIPTION
GE Digital Energy Multilin. Industrial Solutions for Energy Management and Energy Efficiency By John S. Levine, P.E. Levine Lectronics and Lectric, Inc. [email protected]. GE Digital Energy Multilin. - PowerPoint PPT PresentationTRANSCRIPT
1
GE Digital Energy MultilinIndustrial Solutions for Energy
Management and Energy EfficiencyBy
John S. Levine, P.E.Levine Lectronics and Lectric, Inc.
2
Meters andAdvanced Meter Infrastructure
Automation
GE Digital Energy MultilinWe deliver, protect, connect and control & monitor power from generation to critical equipment to consumers; enabling safe, reliable, cleaner, more efficient, and smarter power.
Protection & Control Communications
3
Metering Solutions
4
Basic to Advanced Facilities Metering
EPM2000
EPM6000
PQM II
EPM9000
EPM9800
Basic Power Monitoring
Power Quality & Cost ManagementAdvanced PQ Analysis
Price
Cost-effective option for simple power measurements
SCADA transducer replacement
Dynamic power factor correction
Cost allocation & demand management
Alarms and trending for preventive maintenance
Voltage disturbance recordings
Advanced analysis of power disturbances via high-speed sampling
Power quality compliance audit against utility providers
Time-synchronized power-flow analysis
EPM5350
5
Basic Power Monitoring 3-phase
continuous monitoring
Measure power factor in addition to V,I and frequency
Power Quality& Cost Management Basic Power
Monitoring requirements plus:
Built-in logging• History (trend data)• Sequence of events• Waveform capture• Sag & Swell
Additional power quality metrics
I/O options
Advanced Power Quality Analysis Power Quality &
Cost Management requirements plus:
Sub-cycle transients detection
Flicker reporting IRIG-B time-sync
Basic to Advanced Facilities Metering
6
Smart Load Shed Scheme
7
Smart Load Shed Scheme • Scheme uses Multilin UR relays (F35, F60, G60,
etc.) connected via Ethernet network to calculate power at locations throughout facility
• Analog power values are sent to master C90Plus control and programmable logic within C90Plus determines loads to shed based on user configuration
• C90Plus controller capable of communicating to 32 UR relays located throughout facility
• Smart load shed scheme capable of selecting the next loads to shed based on current profitability of the process or other predetermined criteria
8
G1G2
52 5252
Generator 2Utility Tie Generator 1
52
Admin Offices
52
Process 1
52 52 52
Process 2 Process 3 Process 4
SUT
CUT
SA
d
SG2
CG2
SG1
CG1
SP
1
SP
2
SP
3
SP
4
C90 G60G60
F35 F60 F60 F60 F60
ExampleSmartLoadShedLayout
9
SUT
CUT
SA
d
SG2
CG2
SG1
CG1
SP
1
SP
2
SP
3
SP
4
Generator 2Utility Tie Generator 1
Admin Offices Process 1 Process 2 Process 3 Process 4
Smart Load Shed - Communications Requirements
Analog Power Values over IEC61850 GOOSE Messaging using Plant LAN
10
Smart Load Shed Scheme Benefits• C90Plus can be configured to meet numerous
configurations. It is completely programmable.
• With the addition of UR relays to your facility, the UR relays provide:
State of the art protection & control for your critical assets, such as motors, generators, transformers and feeders
Metering of your critical assets, such as motors, generators, transformers and feeders via Plant LAN.
Reduced downtime with modular construction
11
Intuitive Monitoring & Control Solutions
12
13
Viewpoint MonitoringEasy to use Monitoring and Data Recording
14
SINGLE-LINE MONITORING AND CONTROL
View Single-Line monitoring screens in minutes
TRENDING REPORTS
Historical Record of Monitored Data
PLUG-AND-PLAY MONITORING
Pre-configured screens for instant monitoring
GLOBAL COMTRADE VIEWER
View Waveforms Recorded From your Devices
AUTOMATIC EVENT AND WAVEFORM RETRIEVAL
Effortless Data Archiving
AUTOMATIC EVENT AND WAVEFORM RETRIEVAL
Instant Alarm Notification
Viewpoint MonitoringEasy to use Monitoring and Data Recording for Small to Medium Systems (50 to 150 devices)
15
Many Devices Supported The following Devices and Firmware Versions are supported by Viewpoint Monitoring
You can easily add third party devices.
Viewpoint Monitoring
16
Viewpoint Monitoring: Plug-and-PlayHow to Save Time and Costs with Viewpoint Monitoring
OVERVIEW ALARMS LEARNED
METERING TRIP MAINTENANCE
Operating condition of your motor
Status of your GE Multilin Relay or Meter
Active Alarms detected by the relay
Latched Alarms that require clearing
Learned motor and RTD data
Learned motor load
All metering quantities (Amps, Volts, Power, Demand)
Motor temperature monitored by the RTD’s
Cause of the last motor trip
Pre-trip data
Trip counters and motor Starts
Total motor running hours
17
Instantly view critical data including: • Number of Motor Starts
• Learned Motor Starting Current
• Motor Running Hours
• History of Motor Trips
• Real time power quantities
• Motor Temperature
PLUG-AND-PLAY MOTOR MONITORINGViewpoint Monitoring
18
Instantly view critical data including: • Breaker Status
• Accumulated Breaker Arcing Current
• Real time power quantities (Amps, Volts, Demand, Energy)
• Synchronism data
PLUG-AND-PLAY FEEDER MONITORINGViewpoint Monitoring
19
Instantly view critical data including: • Transformer Energization Status
• Real time power quantities (Amps, Transformer Loading, Demand)
• Current Harmonic Analysis
• Accumulated Loss of Life
• Tap Changer Position
• Hottest Winding Temperature
PLUG-AND-PLAY TRANSFORMER MONITORINGViewpoint Monitoring
20
Instantly view critical data including: • Generator Loading
• Real time power quantities (Amps, Volts)
• Cause of Trip Data
• Generator Running Hours
• History of Generator Trips
• Generator Temperature
PLUG-AND-PLAY GENERATOR MONITORINGViewpoint Monitoring
21
Instantly view critical data including:
• Power Quality and Equipment Status
• Load unbalances using real time and maximum & minimum values
• Cost of Energy using inputs from revenue meters
• Amount of total harmonic distortionon the power system
PLUG-AND-PLAY POWER QUALITY MONITORINGViewpoint Monitoring
22
Instantly view critical data including: • Availability of Normal and Emergency power sources
• Status of Power Source connections
• Real time voltages and frequency
• Switch status, Timer settings, and control Switch Position
• Stored Events and Exerciser Schedules
PLUG-AND-PLAY BACKUP MONITORINGViewpoint Monitoring
23
Instantly view critical data including: • Breaker Status
• Number of breaker trip operations
• Real time Current, Voltage and Power levels
PLUG-AND-PLAY BREAKER MONITORINGViewpoint Monitoring
24
• Identify the status of all the devices in your power system on a customized single-line monitoring screen
• Monitor the magnitude of any power quantity measured by your metering and
protection devices
• Navigate though multiple monitoring screens to view the status of different parts of your network
• Communicate with up to 150 devices and 9000 points
Create single-line monitoring screens in minutes
• Construct system diagrams with drag and drop ease
• Contains all necessary symbols and tools required for replicating your power system
• Includes a library of meters and Dials to graphically represent any metered quantity
Single-Line Monitoring and ControlViewpoint Monitoring
Monitor and Control all devices in your Power System
25
Viewpoint Monitoring
Event Logging
• Automatic download of events which are stored in a system wide Sequence of Event Record
• Devices continually polled to check for new Events
• Sort and Query system event record to view events categorized by date, device type, timestamp, or customized criteria
• No configuration required
Waveform Archiving
• Waveform files from GE Multilin Devices automatically downloaded from a device and stored on your hard drive
• Devices continually polled to check for new Waveforms
• Diagnose waveform fault data recorded in your power system device in a Time-based, Phasor Quantity and Tabular view
Automatic Event and Waveform Retrieval
26
Trending Reports
Historical Record of monitored data• Trend up to 500 data points
(10 records with 50 values each)• Records data with 1 minute resolution indefinitely• View data in time based graphical or tabular format
Annunciator Alarming
Instant Alarm Notification•Create alarms on any monitored analog or digital data point•Receive alarm warnings through Audio, Visual or Email notification
Viewpoint Monitoring
27
• Check the ‘Time Download’ check box for synchronizing your relay’s real-time clock with your Viewpoint Monitoring computer system.
• When this option is enabled, Viewpoint Monitoring will perform the time synchronization in every 12-hour interval between your relay and your Viewpoint Monitoring computer system.
Automatic synchronism of connected device’s time and date
Viewpoint Monitoring
28
•Add any third party device that supports Modbus RTU or Modbus
TCP/IPprotocol
•Add non-GE Multilin devices in your facility
to your Viewpoint Monitoring and Control
System
• Third Party devices can be used in your:
• Single Line Diagrams• Annunciator Panel• Trending Reports
Third Party Device SupportViewpoint Monitoring
29
Provide the data that is being read by the relays and meters to any third party OPC compliant Automation or Monitoring System
• Provide up to 3000 (for 50 devices) or 9000 (for 150 devices) data points (tags) to any OPC client
• Supports the entire library of devices that comes with Viewpoint Monitoring or add other third party Modbus compliant devices
• Ability to provide data for any third party devices added to the Viewpoint Monitoring database
OPC Server OptionViewpoint Monitoring
30
• The EnerVista ViewNode software allows multiple users to remotely monitor and control existing Viewpoint Monitoring systems.
• Multiple user accounts and security levels ensures system information is always accessible and secure.
Key Features include:
• Remotely Access to:One Line DiagramsPlug-and-Play screensAnnunciator PanelsTrending reportsSequence of Events and Waveforms
• Up to 10 ViewNodes can access a single Viewpoint Monitoring server
• Multiple user accounts and security levels ensures secure monitoring and control of your system
Remote Monitoring & ControlViewNodes
31