ge digital energy multilin

31
1 GE Digital Energy Multilin Industrial Solutions for Energy Management and Energy Efficiency By John S. Levine, P.E. Levine Lectronics and Lectric, Inc. [email protected]

Upload: dieter-campbell

Post on 03-Jan-2016

85 views

Category:

Documents


7 download

DESCRIPTION

GE Digital Energy Multilin. Industrial Solutions for Energy Management and Energy Efficiency By John S. Levine, P.E. Levine Lectronics and Lectric, Inc. [email protected]. GE Digital Energy Multilin. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: GE Digital Energy Multilin

1

GE Digital Energy MultilinIndustrial Solutions for Energy

Management and Energy EfficiencyBy

John S. Levine, P.E.Levine Lectronics and Lectric, Inc.

[email protected]

Page 2: GE Digital Energy Multilin

2

Meters andAdvanced Meter Infrastructure

Automation

GE Digital Energy MultilinWe deliver, protect, connect and control & monitor power from generation to critical equipment to consumers; enabling safe, reliable, cleaner, more efficient, and smarter power.

Protection & Control Communications

Page 3: GE Digital Energy Multilin

3

Metering Solutions

Page 4: GE Digital Energy Multilin

4

Basic to Advanced Facilities Metering

EPM2000

EPM6000

PQM II

EPM9000

EPM9800

Basic Power Monitoring

Power Quality & Cost ManagementAdvanced PQ Analysis

Price

Cost-effective option for simple power measurements

SCADA transducer replacement

Dynamic power factor correction

Cost allocation & demand management

Alarms and trending for preventive maintenance

Voltage disturbance recordings

Advanced analysis of power disturbances via high-speed sampling

Power quality compliance audit against utility providers

Time-synchronized power-flow analysis

EPM5350

Page 5: GE Digital Energy Multilin

5

Basic Power Monitoring 3-phase

continuous monitoring

Measure power factor in addition to V,I and frequency

Power Quality& Cost Management Basic Power

Monitoring requirements plus:

Built-in logging• History (trend data)• Sequence of events• Waveform capture• Sag & Swell

Additional power quality metrics

I/O options

Advanced Power Quality Analysis Power Quality &

Cost Management requirements plus:

Sub-cycle transients detection

Flicker reporting IRIG-B time-sync

Basic to Advanced Facilities Metering

Page 6: GE Digital Energy Multilin

6

Smart Load Shed Scheme

Page 7: GE Digital Energy Multilin

7

Smart Load Shed Scheme • Scheme uses Multilin UR relays (F35, F60, G60,

etc.) connected via Ethernet network to calculate power at locations throughout facility

• Analog power values are sent to master C90Plus control and programmable logic within C90Plus determines loads to shed based on user configuration

• C90Plus controller capable of communicating to 32 UR relays located throughout facility

• Smart load shed scheme capable of selecting the next loads to shed based on current profitability of the process or other predetermined criteria

Page 8: GE Digital Energy Multilin

8

G1G2

52 5252

Generator 2Utility Tie Generator 1

52

Admin Offices

52

Process 1

52 52 52

Process 2 Process 3 Process 4

SUT

CUT

SA

d

SG2

CG2

SG1

CG1

SP

1

SP

2

SP

3

SP

4

C90 G60G60

F35 F60 F60 F60 F60

ExampleSmartLoadShedLayout

Page 9: GE Digital Energy Multilin

9

SUT

CUT

SA

d

SG2

CG2

SG1

CG1

SP

1

SP

2

SP

3

SP

4

Generator 2Utility Tie Generator 1

Admin Offices Process 1 Process 2 Process 3 Process 4

Smart Load Shed - Communications Requirements

Analog Power Values over IEC61850 GOOSE Messaging using Plant LAN

Page 10: GE Digital Energy Multilin

10

Smart Load Shed Scheme Benefits• C90Plus can be configured to meet numerous

configurations. It is completely programmable.

• With the addition of UR relays to your facility, the UR relays provide:

State of the art protection & control for your critical assets, such as motors, generators, transformers and feeders

Metering of your critical assets, such as motors, generators, transformers and feeders via Plant LAN.

Reduced downtime with modular construction

Page 11: GE Digital Energy Multilin

11

Intuitive Monitoring & Control Solutions

Page 12: GE Digital Energy Multilin

12

Page 13: GE Digital Energy Multilin

13

Viewpoint MonitoringEasy to use Monitoring and Data Recording

Page 14: GE Digital Energy Multilin

14

SINGLE-LINE MONITORING AND CONTROL

View Single-Line monitoring screens in minutes

TRENDING REPORTS

Historical Record of Monitored Data

PLUG-AND-PLAY MONITORING

Pre-configured screens for instant monitoring

GLOBAL COMTRADE VIEWER

View Waveforms Recorded From your Devices

AUTOMATIC EVENT AND WAVEFORM RETRIEVAL

Effortless Data Archiving

AUTOMATIC EVENT AND WAVEFORM RETRIEVAL

Instant Alarm Notification

Viewpoint MonitoringEasy to use Monitoring and Data Recording for Small to Medium Systems (50 to 150 devices)

Page 15: GE Digital Energy Multilin

15

Many Devices Supported The following Devices and Firmware Versions are supported by Viewpoint Monitoring

You can easily add third party devices.

Viewpoint Monitoring

Page 16: GE Digital Energy Multilin

16

Viewpoint Monitoring: Plug-and-PlayHow to Save Time and Costs with Viewpoint Monitoring

OVERVIEW ALARMS LEARNED

METERING TRIP MAINTENANCE

Operating condition of your motor

Status of your GE Multilin Relay or Meter

Active Alarms detected by the relay

Latched Alarms that require clearing

Learned motor and RTD data

Learned motor load

All metering quantities (Amps, Volts, Power, Demand)

Motor temperature monitored by the RTD’s

Cause of the last motor trip

Pre-trip data

Trip counters and motor Starts

Total motor running hours

Page 17: GE Digital Energy Multilin

17

Instantly view critical data including: • Number of Motor Starts

• Learned Motor Starting Current

• Motor Running Hours

• History of Motor Trips

• Real time power quantities

• Motor Temperature

PLUG-AND-PLAY MOTOR MONITORINGViewpoint Monitoring

Page 18: GE Digital Energy Multilin

18

Instantly view critical data including: • Breaker Status

• Accumulated Breaker Arcing Current

• Real time power quantities (Amps, Volts, Demand, Energy)

• Synchronism data

PLUG-AND-PLAY FEEDER MONITORINGViewpoint Monitoring

Page 19: GE Digital Energy Multilin

19

Instantly view critical data including: • Transformer Energization Status

• Real time power quantities (Amps, Transformer Loading, Demand)

• Current Harmonic Analysis

• Accumulated Loss of Life

• Tap Changer Position

• Hottest Winding Temperature

PLUG-AND-PLAY TRANSFORMER MONITORINGViewpoint Monitoring

Page 20: GE Digital Energy Multilin

20

Instantly view critical data including: • Generator Loading

• Real time power quantities (Amps, Volts)

• Cause of Trip Data

• Generator Running Hours

• History of Generator Trips

• Generator Temperature

PLUG-AND-PLAY GENERATOR MONITORINGViewpoint Monitoring

Page 21: GE Digital Energy Multilin

21

Instantly view critical data including:

• Power Quality and Equipment Status

• Load unbalances using real time and maximum & minimum values

• Cost of Energy using inputs from revenue meters

• Amount of total harmonic distortionon the power system

PLUG-AND-PLAY POWER QUALITY MONITORINGViewpoint Monitoring

Page 22: GE Digital Energy Multilin

22

Instantly view critical data including: • Availability of Normal and Emergency power sources

• Status of Power Source connections

• Real time voltages and frequency

• Switch status, Timer settings, and control Switch Position

• Stored Events and Exerciser Schedules

PLUG-AND-PLAY BACKUP MONITORINGViewpoint Monitoring

Page 23: GE Digital Energy Multilin

23

Instantly view critical data including: • Breaker Status

• Number of breaker trip operations

• Real time Current, Voltage and Power levels

PLUG-AND-PLAY BREAKER MONITORINGViewpoint Monitoring

Page 24: GE Digital Energy Multilin

24

• Identify the status of all the devices in your power system on a customized single-line monitoring screen

• Monitor the magnitude of any power quantity measured by your metering and

protection devices

• Navigate though multiple monitoring screens to view the status of different parts of your network

• Communicate with up to 150 devices and 9000 points

Create single-line monitoring screens in minutes

• Construct system diagrams with drag and drop ease

• Contains all necessary symbols and tools required for replicating your power system

• Includes a library of meters and Dials to graphically represent any metered quantity

Single-Line Monitoring and ControlViewpoint Monitoring

Monitor and Control all devices in your Power System

Page 25: GE Digital Energy Multilin

25

Viewpoint Monitoring

Event Logging

• Automatic download of events which are stored in a system wide Sequence of Event Record

• Devices continually polled to check for new Events

• Sort and Query system event record to view events categorized by date, device type, timestamp, or customized criteria

• No configuration required

Waveform Archiving

• Waveform files from GE Multilin Devices automatically downloaded from a device and stored on your hard drive

• Devices continually polled to check for new Waveforms

• Diagnose waveform fault data recorded in your power system device in a Time-based, Phasor Quantity and Tabular view

Automatic Event and Waveform Retrieval

Page 26: GE Digital Energy Multilin

26

Trending Reports

Historical Record of monitored data• Trend up to 500 data points

(10 records with 50 values each)• Records data with 1 minute resolution indefinitely• View data in time based graphical or tabular format

Annunciator Alarming

Instant Alarm Notification•Create alarms on any monitored analog or digital data point•Receive alarm warnings through Audio, Visual or Email notification

Viewpoint Monitoring

Page 27: GE Digital Energy Multilin

27

• Check the ‘Time Download’ check box for synchronizing your relay’s real-time clock with your Viewpoint Monitoring computer system.

• When this option is enabled, Viewpoint Monitoring will perform the time synchronization in every 12-hour interval between your relay and your Viewpoint Monitoring computer system.

Automatic synchronism of connected device’s time and date

Viewpoint Monitoring

Page 28: GE Digital Energy Multilin

28

•Add any third party device that supports Modbus RTU or Modbus

TCP/IPprotocol

•Add non-GE Multilin devices in your facility

to your Viewpoint Monitoring and Control

System

• Third Party devices can be used in your:

• Single Line Diagrams• Annunciator Panel• Trending Reports

Third Party Device SupportViewpoint Monitoring

Page 29: GE Digital Energy Multilin

29

Provide the data that is being read by the relays and meters to any third party OPC compliant Automation or Monitoring System

• Provide up to 3000 (for 50 devices) or 9000 (for 150 devices) data points (tags) to any OPC client

• Supports the entire library of devices that comes with Viewpoint Monitoring or add other third party Modbus compliant devices

• Ability to provide data for any third party devices added to the Viewpoint Monitoring database

OPC Server OptionViewpoint Monitoring

Page 30: GE Digital Energy Multilin

30

• The EnerVista ViewNode software allows multiple users to remotely monitor and control existing Viewpoint Monitoring systems.

• Multiple user accounts and security levels ensures system information is always accessible and secure.

Key Features include:  

• Remotely Access to:One Line DiagramsPlug-and-Play screensAnnunciator PanelsTrending reportsSequence of Events and Waveforms

• Up to 10 ViewNodes can access a single Viewpoint Monitoring server

• Multiple user accounts and security levels ensures secure monitoring and control of your system

Remote Monitoring & ControlViewNodes

Page 31: GE Digital Energy Multilin

31