GC-MSD Introducing the new 7890B/5977A
January 8, 2013 Agilent Confidential
Badr Astiphan GCMS Product Sales Specialist 1-866-524-7936 302-290-5631 cell [email protected]
January 8, 2013 Agilent Confidential
2
We are First in GC Continuously innovating
5970 MSD Fused Silica Capillary Column
Microprocessor Control
5840 GC
5880 GC
5890 GC
Hyperbolic Gold Quad
Inert MS Ion Source
6890 GC
7200 GC QTOF 7000 GC
Triple Quad
Capillary Flow Technology
AutoInjection
Electronic Pneumatic Control
Retention Time Locking
2nd Gen Linear Electron Capture
Detector
Low Thermal Mass Technology
Units Installed >250,000 GC >60,000 MS
Multi-Mode Inlet
January 8, 2013 Agilent Confidential
3
7890A/5975C GC/MSD: The Most Popular GC/MS in the World
Over 20,000 5975 systems since 2005
The industry standard GCMS
Proven Technologies Improving the Industry Standards for GC/SQ
Gold Quartz Quad Triple Axis Detector
High Temperature Inert Source Unique Entrance
Lens Design
All of 5975’s features also built in 5977, such as “Gold Quad”, SIM/Scan, Gain tuning, Triple-Axis Detector, Trace Ion Detection, Auto CI, etc..
January 8, 2013 Agilent Confidential
5
230°C
275°C
300°C
325°C
350°C
January 8, 2013 Agilent Confidential
6
High Temperature Ion Source Solid inert material – not a coating
– Not damaged by multiple cleanings Programmable to 350ºC Improved response for many compounds
– More robust operation for “dirty” samples – Better response for “sticky” compounds – Sharper peaks for high boilers (late eluters)
… more performance for a wide range of applications
Polyaromatic Hydrocarbon (PAH)
January 8, 2013 Agilent Confidential
7
Unique Entrance Lens Eliminates Pre-filter
New, improved lens
January 8, 2013 Agilent Confidential
9
Quartz – Gold – Hyperbolic and Beautiful!
Why quartz?
– Low coefficient of linear expansion
(expansivity; α)
• dL = α L0 dt [t = ºC; dL = change in
length (m); L0 = length at 0 ºC]
Why gold?
– Inert material with excellent electrical
properties for high voltage
Why hyperbolic?
– Ideal electrical field is generated by
hyperbolic surfaces (NOT ROUND)
Much more than just a beautiful piece of glass
Round Quad
January 8, 2013 Agilent Confidential
10
Triple-Axis Detector
ion beam X
Y
Offset Z
With a combination of three axes and appropriate shielding, noise from secondary particles can be reduced to a minimum
January 8, 2013 Agilent Confidential
11
Triple Channel EM
Triple channels improve signal amplification
– Lower initial EM voltage required Triple channels increase life
– Lower cost of operation
Exit of the triple channels
Collector removed to show exit passages
Collector
Expanded Capabilities: 7890B/5977A Improving the Industry Standards for GC/SQ
Higher Ion Count • Extractor EI source
• Increased ion count • S/N > 1500:1 • IDL < 10 fg (industry first) • Improved thermal profile
Save Time & Energy •Sequence Scheduler
• “Standby” post run • “Ready to run” from standby • “Bake Mode” as needed
• Factory backflush option • Fast Vent capability • DS42i rough pump“standby” power reduction
Safety/Protection • Vacuum failure Shut off gas (He or H2)
Better Vacuum by Agilent Pump • New Agilent V304 Turbo • TwisTorr
• Molecular Drag technology • Improved pumping light gases
• H2 (220 L/s); He (255 L/s) • Agilent Floating Suspension
• Longer life • Quiet operation
Faster Scanning • 20,000 u/s
• But never equal to the 7200 Q-TOF speed or ‘scan’ sensitivity
7890B GC “Direct Communications Features • EMF, calculator, etc.
January 8, 2013 Agilent Confidential
12
New Extractor Ion Source for 5977
Agilent Confidential Page 13
Why the Extractor EI Source? Increase in ion count True increase in sensitivity
Better trace level precision Lower IDL and MDL
Proven sensitivity increase demonstrated with over 1500 7000 Series GC/TQ!
January 8, 2013
Comparison of Inert and Extractor Ion Source
Agilent Confidential
Page 14
Repeller (Push)
Drawout Plate
Ion Focus Lens
Entrance Lens
Ionization area
Ions
Inert Ion Source
Extractor Lens (Pull)
Extractor Source More ions to Mass Filter
Mass Filter
January 8, 2013
Extractor Source “Etune” Sensitivity Increase
January 6, 2013 Agilent Confidential
15
Blue – Extractor 40ppb solution (SVOC) Red – Standard 40ppb solution (SVOC)
More improvements on 5977’s Extractor Ion Source: Improved Thermal Profile
Page 16
Why is this important? Better performance of high boilers i.e. PAH even at lower concentration!
10 Injections 80 min analysis
Good repeatability of PAH even at the trace level (5ppb)!!
Improvement for better Mass Spectrometer of Gas Chromatograph
January 15, 2013
Comparing repeatability of 80min Method
Phthalates analysis with 5977 GC/MSD
Oct 2012 Page 17
1x10
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
+ TIC SIM PAHs-12.D
Counts (%) vs. Acquisition Time (min)
37 37.1 37.2 37.3 37.4 37.5 37.6 37.7 37.8 37.9 38 38.1 38.2 38.3 38.4 38.5 38.6 38.7 38.8 38.9
5977 result
5975 result Two years ago
1x10
-0
-0
0
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
1
1.
1.
1.
1
+ TIC SIM pah_etune_300_long_R9.D Smooth
Counts (%) vs. Acquisition Time (min)
35.2 35.4 35.6 35.8 36 36.2 36.4 36.6 36.8 37 37.2 37.4 37.6 37.8 38 38.2 38.4 38.6 38.8 39 39.2 39.4 39.6 39.8 40
5977 result
200ppb PAH 5ppb PAH
Key features of “Direct Communication” between 7890B and 5977A
Agilent Confidential Page 18
Sleep/Wake mode • Sleep mode saves power (320W 190W) Lower lab operating cost
Safety Control • If 5977A MSD pump fail, 7890B will shut off the gas supply
Cool Down MSD Faster (FastVent) • When MSD Vent Cycle started, GC will cool down MSD analyzer at the
optimum gas flow to MSD.
Helium carrier gas : gas waste is eliminated Hydrogen carrier gas: risk of explosion is reduced
40% faster when cooling down from 280C to 100C (< 25 min)
January 8, 2013
Saving Energy and Time
19
050
100150200250300350400
NormalOp
Standby
Power Consumption - 5977
0
50
100
150
200
250
0 4 6 7 15 20 23 30 35 40
Vent FastVent
Power saved
Time saved
Pow
er( V
A)
Sour
ce T
emp
Time(min)
Time saved using Fast Vent
Better HW Features: Agilent Turbo Pump (V304)
Agilent Confidential Page 20
Agilent Quality Standard
TwisTorr 304 FS
Innovation for: •Higher pumping performance
• especially for He and H2 •High reliability
• lower cost of operation
January 8, 2013
Press release : http://www.agilent.com/about/newsroom/presrel/2012/19dec-ca12077.html
21
TwisTorr 304 FS: Vacuum Design
8 EDM turbo stages (rotor) designed to optimize pumping speed for light gases 8 Turbo stators
made by pressed SST sheet technology
3 TwisTorr drag stages (spiral channels) designed for high compression ratio performances
Agilent’s new patent-pending Floating Suspension for robust, low noise operation
Better HW Features: Agilent Rough Pumps
Agilent Confidential Page 22
New DS42i New IDP-3c
High performance Energy saving design “Inverter” not compatible with diff pump
High performance Oil-free scroll pump NH3 CI compatible
with Agilent Quality Standards
January 8, 2013
January 8, 2013 Agilent Confidential
23
Agilent Inert Flow Path … From Injection to Detection
Ultimetal – TCD, FPD, NPD/FID Jets
Ultimetal Capillary Flow Technology Devices, Ultimate Union
Ultimetal Inlet Weldment, Shell and Transfer Lines
Ultra Inert GC Column
Ultra Inert Gold Seal
Ultra Inert Inlet Liner
New
…now from a single supplier
Programmable Helium Conservation Module
Works with Gas Saver function of 7890 based GC Standby Method can be programmed after the sequence ends Analytical methods are unchanged since Helium is still the carrier during the run
5977A GC/MSD IDL Specification IDL is a statistically derived value from the precision (%RSD) of 8 consecutive, splitless injections of 100fg OFN at 99 % confidence level. The more precise instruments (lower %RSD) will generate lower IDLs.
The Agilent 7890B/5977A with an ALS or CTC autosampler has the following specifications:
January 15, 2013 25
Ion Source type High Vacuum pump type IDL of OFN by 8 replicates of ALS*
Extractor Source Turbo Pump 10fg
Inert Source Turbo Pump 24fg
Diffusion Pump 30fg
*Systems without an Autosampler will have only S/N specification.
These are installation specification, performed on customer site, immediately after installation and carry a lot more value than a reference specs.
Why IDL specification is useful for the 5977 in SIM? Influence of Noise in S/N specs • In SIM (or MS/MS) when the Noise is too low, such as during acquisition of
an OFN standard, S/N results may not give the best characterization
• If the noise level is insignificant - varies a lot and too low- the derived value from it (S/N) also becomes insignificant
Value of IDL • IDL is derived from reproducibility/precision results, the same metrics most
users utilize every day in their work. The IDL statistical process is the same used for Method Detection Limit calculations, and the %RSD values are tools to monitor analytical performance
• IDL characterizes the whole system – AS, GC, MS- giving confidence in overall reliability. It is the results of 8 consecutive injections, unlike S/N in a single shut, which can be influenced by many parameters/conditions
January 15, 2013 26
The Influence of the low Noise on S/N values Same Data File, RMS, 5 Second Noise Region
Noise region: 5.66min - 5.74 min S/N: 3335
Noise region: 5.65min - 5.73 min S/N: 10785
A 0.01 min. shift in the noise region resulted a 6000 higher S/N value. When the noise is insignificant (low), the derived S/N value is also insignificant!
Noise region: 5.65min-5.73 min
Noise region: 5.66min-5.74 min
S/N S/N
January 15, 2013 27
January 8, 2013 Agilent Confidential
28
Market Leading Performance Premium Value: The Best Just Got Better
Detector Performance MSD Scan 1500:1 S/N; SIM 10 fg IDL – Best in Class with IDL
tested at installation when ALS or Combi available (with Extractor Source)
FID <1.4 pg C/sec ECD <4.4 fg/sec FPD <2.5 pg S/sec; <45 fg P/sec SCD <0.5 pg S/sec NPD Best for P, 0.08 pg/sec N beat only by Thermo 0.05 pg/sec–
but only using OUR Blos bead! TCD 400 pg/mL
No one can now offer a better specification package than Agilent
Agilent Confidential Page 29
Market’s Best S/N (SNR) > 1500:1 Market’s Best Scan Rate = 20,000 u/s
Market’s ONLY IDL < 10 fg Better from Agilent Statistical confirmation of entire system’s performance
January 8, 2013
January 8, 2013 Agilent Confidential
30
Mass Hunter GC/MSD Software MassHunter Qual
MassHunter Quant MH
CS
MassHunter GC/MS Acquisition And Use Either MassHunter Data Analysis OR MSD ChemStation Data Analysis MSD ChemStation DA
G1701FA
January 8, 2013 Agilent Confidential
31
MSD ChemStation DA
QEdit
Reports
MSD ChemStation Standard interface
Quantitation
Macros
Library Searching
January 8, 2013 Agilent Confidential
32
MassHunter WorkStation Qualitative Analysis Data Navigator
Method Explorer
Chromatogram Results
Method Editor
Spectrum Results
January 8, 2013 Agilent Confidential
33
Mass Hunter Quantitative Analysis
Compound Information
Results Information
Batch Information (i.e., Calibration Curve)
Results Information for the batch can be displayed. Visual guides highlight specific data that fall outside specific, predefined conditions.
Batch Information provides easy visualization and customization of relevant desired data.
The Quant Batch screen looks like this.
Compound Information displays graphical representation of the peak, qualifier information, spectral information, and the ISTD. Visual guides help identify associated data problems.
January 8, 2013 Agilent Confidential
35
MassHunter Excel Reporting
•Excel Based (Excel 2010 supported)
•MassHunter application exports data in XML and graphics files
•Templates define report formatting
•Over 100 shipping report templates
•Reports can be altered for desired information & appearance
•Customization using Excel features (function, formatting, code)
•Computer Based Training for report customization by users
•Some customization available through Agilent
Flexibility: Performance and Budget
Page 37
Lowest Price Performance Meets Method Requirement
5977E Turbo MS 5977E Diff MS
7820A Stainless source
Highest GC Performance & MS Performance
5977A EI 5977A EI/CI
7890B GC Extractor source DS42i
Balance of Price, GC performance, & MS performance
5977A Turbo MS 5977A Diff MS
7890B GC Inert source