flygt pumps

104
Product catalogue Submersible pumps C 3000, 50 Hz

Upload: achira-chanaka-peiris

Post on 07-Nov-2014

2.966 views

Category:

Documents


218 download

DESCRIPTION

Flygt Submersible pump prduct catalogue

TRANSCRIPT

Page 1: Flygt Pumps

Product catalogue

Submersible pumps C 3000, 50 Hz
Page 2: Flygt Pumps

Introduction ................................................3

Design - small pumps ................................4

Design - medium pumps ............................5

Product identity ..........................................6

C 3045 .......................................................7

C 3057 .....................................................11

C 3060 .....................................................16

C 3068 .....................................................20

C 3085 .....................................................24

C 3102 ..................................................... 31

C 3126 ..................................................... 39

C 3127 ..................................................... 45

C 3140 ..................................................... 57

C 3152 ..................................................... 63

C 3170 ..................................................... 72

C 3201 ..................................................... 81

C 3300 ..................................................... 89

Contents

The manufacturer reserves the right to alter specifications and design.

Choosing the right pumpThere are a wide range of pumps to select from. In order to find the right pump size, that matches the system requirements, the duty point for the system

must be calculated. Then a suitable pump can be chosen from the performace curves. For more detailed analysis, please contact your ITT Flygt representative.

1. Calculate the duty point (a) for the system.

2. Choose a pump model from the family of curves that match the system requirements.

3. Choose curve (b) according to calculated duty point.

��

��

Page 3: Flygt Pumps

C 3000

IntroductionThis series of pumps covers an extensive performance range and can be used in a variety of applications: from pumping sewage in treatment plants and municipal applications, irrigation and industrial effluent to process water and raw water handling and application in aqua and agriculture.

The hydraulic sections, i.e. impeller and volute, are designed for applications in which the waste water is either clean, or between slightly and moderately contaminated, and for handling solids.

The standard version of these pumps, are made in cast iron and for more demanding applications the pumps can be supplied in industrial configuration. Special models are also available in explosion-proof versions.

����

����

����

����

����

����

����

����

����

����

����

����

���

���

����

�������������������

��

��

��

���

��

����

3

Page 4: Flygt Pumps

C 3000

Design - small pumps

1. Cooling. Motor casings with integral cooling ribs.

2. Motor. Squirrel-cage induction motor with 2, 4 or 6 pole windings. The stator insulation system is Class H (rated 180 °C) allowing up to 15 starts/hour.

3. Cable junction chamber. The junction chamber is completely sealed off from surrounding liquid and incorporates separate gland assembly with strain relief clamp.

4. Pump/motor shaft. Common pump/motor shaft and compact seal design. Rotor and shaft dynamically balanced as an integral assembly.

5. Bearings. Pre-greased rolling element bearings. Bearing calculations are made for 50000 hours of duty all to ISO standard.

6. Shaft sealing. Two independent mechanical face seals assembled in tandem provide reliable and durable sealing performance and maximum resistance to abrasion and thermal shock.

7. Oil casing. Oil filled housing for lubricating and cooling mechanical seal units provides an additional leakage barrier.

8. Impeller. Dynamically balanced single and two vane versions to

accurately match required performance. The NevaClog® impellers are available for various models.

9. Pump casing. With smooth profiled volute geometry for clog-free

operation. A spiral groove (SPIN OUT®) in the pump housing protects the outer seal by expelling abrasive particles from the seal chamber.

10. Wear rings. Replaceable for high pumping efficiency.

��

4

Page 5: Flygt Pumps

C 3000

Design - medium pumps

1. Cable junction chamber. Sealed terminal chamber with separate cable gland assemblies incorporating strain relief clamp.

2. Motor. Squirrel-cage induction motor with 2, to 8 pole windings. The stator insulation system is Class H (rated 180 °C) allowing up to 15 starts/hour.

3. Cooling. Motor casing with integral cooling ribs for maximum heat dissipation. Larger motors are equipped with outer cooling jackets for the circulation of a portion of the pumped liquid or external water supply.

4. Pump/motor shaft. Common pump/motor shaft and compact seal design. Rotor and shaft dynamically balanced as an integral assembly.

5. Bearings. Pre-greased rolling element bearings. Bearing calculations are made for 50000 hours of duty all to ISO standard.

6. Oil casing. Oil filled housing for lubricating and cooling mechanical seal units provides an additional leakage barrier.

7. Shaft sealing. Two independent mechanical face seals assembled in tandem provide reliable and durable sealing performance and maximum resistance to abrasion and thermal shock

8. Impeller. Dynamically balanced single, two and three vane versions to accurately match required performance. The NevaClog® impellers available for various models.

9. Pump casing. With smooth profiled volute geometry for clog-free operation fitted with replaceable wear rings. A spiral groove (SPIN OUT®) in the pump housing protects the outer seal by expelling abrasive particles from the seal chamber.

��

5

Page 6: Flygt Pumps

C 3000

Product identityITT Flygt uses a simple system to code and thereby identify its products. Each pump is given a code made up of two letters followed by four numbers, e.g., CP 3085. The first letter refers to the pump’s hydraulic section, i.e., the impeller and volute. It also refers to the pump, as the impeller used determines the pump type. The second letter refers to the pump’s method of installation: semi-

permanent free-standing, permanent dry vertically mounted, portable etc.

The four numbers refer to the pump’s model as well as specify its size in comparison to other pumps of the same type. Thus pump CP3085 is larger than CP 3067.

Impeller characteristicThe pumps are divided into different classes according to their operating area;

LT - Low head versionMT - Medium head versionHT - High head versionST - Super head version

Impeller and volute

Methods of installation

Single vane impeller. The size of the channel comparatively large. Used

when good solids-passing is needed.

Multi-vane impeller. Used in applications with clean or slightly

contaminated water.

C C

A semi-permanent, free-standing installation. Transportable version with

pipe or hose connection.

For semi-permanent wet well installations. The pump is installed with

twin guide bars on a discharge connection.

A portable solution with hose coupling or flange for connection to a discharge

pipeline.

A vertically-mounted, permanent dry well or in-line installation with flange

connections for suction and discharge pipe work.

A horizontally-mounted, permanent dry well or in-line installation with

flange connections for suction and discharge pipe work

F P S

T Z

6

Page 7: Flygt Pumps

C 3045

C 3045ProductSubmersible pump for pumping waste water and sludge. It can also be used for pumping ground water and other liquids containing solids.

DenominationProduct code 3045.180

Installation F, H, P, S

Impeller characteristic HT

Process data Liquid temperature max +40 °C

Depth of immersion max 20 m

The pH of the pumped liquid pH 6-11

Liquid density max. 1100 kg/m3

Motor dataFrequency 50 Hz

Insulation class F (+155 °C)

Voltage variation

- continuously running max ± 5%

- intermittent running max ± 10%

Voltage imbalance between phases max 2%

No. of starts/hour max 15

CableDirect-on-line startSUBCAB® 4G2,5 mm2

4G2,5+2x1,5 mm2

Y/D startSUBCAB® 7G2,5 mm2

MaterialImpeller Polyamide

Pump housing Cast iron

Stator housing Cast iron

Shaft Stainless steel

O-rings Nitrile rubber

Mechanical face seals

Surface TreatmentAll cast parts are primed with a water-borne primer. The finishing coat is a high-solid two pack paint.

WeightSee dimensional drawing.

Option3045.090 Ex. proof design

Warm liquid version on request

Leakage sensor in stator housing FLS

Other cables

Zinc anodes

AccessoriesDischarge connections, adapters, hose connections and other mechanical accessories.

Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables.

See separate booklet or www.flygt.com, for further information.

Alternative Inner seal Outer seal

1 Carbon/Aluminium oxide

Silicon carbide/Silicon carbide

7

Page 8: Flygt Pumps

C 3045

HT-Motor rating and performance curve

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

rou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

F H P S

400 V, 50 Hz, 3 ~, 2870 r/min

252 0,8 2,0 14,0 0,74 44 No • • • •

400 V, 50 Hz, 3 ~, 2790 r/min

250 1,2 2,6 14,0 0,84 44 Yes • • • •

252 1,2 2,6 14,0 0,84 45 Yes • • • •

230 V, 50 Hz, 1 ~, 2750 r/min

252 0,75 4,2 15,0 0,99 44 No • • • •

Q [l/s]

H [m]

2P [kW]

0 2 4 6 8 100

2

4

6

8

10

12

14

16

0.6

0.8

1.0

1.2

1.4

HT

250

250

252

252

8

Page 9: Flygt Pumps

C 3045

Dimensional drawingAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Download the drawings from www.flygt.com or contact your ITT Flygt representative for more information.

All dimensions are in mm.

HT, F-installation HT, H-installation

9

Page 10: Flygt Pumps

C 3045

HT, P-installation HT, S-installation

10

Page 11: Flygt Pumps

C 3057

C 3057ProductSubmersible pump for pumping waste water and sludge. It can also be used for pumping ground water and other liquids containing solids.

DenominationProduct code 3057.181

Installation F, H, P, S

Impeller characteristic HT

Process data Liquid temperature max +40 °C

Depth of immersion max 20 m

The pH of the pumped liquid pH 6-11

Liquid density max. 1100 kg/m3

Motor dataFrequency 50 Hz

Insulation class F (+155 °C)

Voltage variation

- continuously running max ± 5%

- intermittent running max ± 10%

Voltage imbalance between phases max 2%

No. of starts/hour max 15

CableDirect-on-line startSUBCAB® 4G1,5 mm2

4G2,5+2x1,5 mm2

Y/D startSUBCAB® 7G2,5 mm2

Monitoring equipmentLeakage sensor in stator housing FLS

MaterialImpeller Polyamide

Pump housing Cast iron

Stator housing Cast iron

Shaft Stainless steel

O-rings Nitrile rubber

Mechanical face seals

Surface TreatmentAll castings are painted with a primer. The finishing coat is of synthetic resin enamel in blue paint.

WeightSee dimensional drawing.

Option3057.091 Ex. proof design

Warm liquid version on request

Other cables

Thermal switches in stator windings

Zinc anodes

AccessoriesDischarge connections, adapters, hose connections and other mechanical accessories.

Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables.

See separate booklet or www.flygt.com, for further information

Alternative Inner seal Outer seal

1 Aluminium oxide/Corrosion resistant cemented carbide

Aluminium oxide/Aluminium oxide

11

Page 12: Flygt Pumps

C 3057

HT-Motor rating and performance curve

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

rou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

F H P S

400 V, 50 Hz, 3 ~, 2695 r/min

250 1,7 3,8 17,0 0,87 48 Yes • • •

250 1,7 3,8 17,0 0,87 48 No •

252 1,7 3,8 17,0 0,87 48 Yes • • •

252 1,7 3,8 17,0 0,87 48 No •

254 1,7 3,8 17,0 0,87 48 Yes • • •

254 1,7 3,8 17,0 0,87 48 No •

400 V, 50 Hz, 3 ~, 2700 r/min

250 2,4 5,3 24,0 0,87 48 Yes • • •

250 2,4 5,3 24,0 0,87 48 No •

252 2,4 5,3 24,0 0,87 48 Yes • • •

252 2,4 5,3 24,0 0,87 48 No •

254 2,4 5,3 24,0 0,87 48 Yes • • •

254 2,4 5,3 24,0 0,87 48 No •

230 V, 50 Hz, 1 ~, 2730 r/min

252 1,5 8,9 28,0 0,99 48 No • • • •

254 1,5 8,9 28,0 0,99 48 No • • • •

������

����

�� ����

� � � � �� �� ��

��

��

��

���

���

���

���

���

���

���

���

��

��

12

Page 13: Flygt Pumps

C 3057

Dimensional drawingAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Download the drawings from www.flygt.com or contact your ITT Flygt representative for more information.

All dimensions are in mm.

HT, F-installation HT, F-installation

13

Page 14: Flygt Pumps

C 3057

HT, H-installation HT, P-installation

HT, P-installation HT, P-installation

14

Page 15: Flygt Pumps

C 3057

HT, P-installation HT, S-installation

HT, S-installation

15

Page 16: Flygt Pumps

C 3060

C 3060ProductSubmersible pump for use in highly corrosive industrial waste water.

DenominationProduct code 3060.390

Installation P, S, T

Impeller characteristics MT, HT

Process data Liquid temperature max +40 °C

Depth of immersion max 20 m

The pH of the pumped liquid pH 0 -14

Liquid density max. 1100 kg/m3

Impeller throughlet See Motor rating table

Motor dataFrequency 50 Hz

Insulation class H (+180 °C)

Voltage variation

- continuously running max ± 5%

- intermittent running max ± 10%

Voltage imbalance between phases max 2%

No. of starts/hour max 15

CableDirect-on-line startSUBCAB® 4G1,5 mm2

4G1,5+2x1,5 mm2

4G2,5 mm2

4G2,5+2x1,5 mm2

Monitoring equipmentThermal contacts opening temperature 125 °C

MaterialImpeller Stainless steel

Pump housing Stainless steel

Stator housing Stainless steel

Shaft Stainless steel

O-rings Fluorinated rubber

Mechanical face seals

WeightSee dimensional drawing.

OptionOther cables

AccessoriesDischarge connections, adapters, hose connections and other mechanical accessories.

Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables.

See separate booklet or www.flygt.com, for further information.

Alternative Inner seal Outer seal

1 Aluminium oxide/Aluminium oxide

Aluminium oxide/Aluminium oxide

16

Page 17: Flygt Pumps

C 3060

������

����

�� ����

� � � � �� �� � ���

��

��

��

���

���

���

���

��

���

���

���

���

���

���

������

����

�� ����

� � � � � � ��

��

��

��

��

��

��

���

���

���

���

���

���

���

���

���

MT-Motor rating and performance curve

HT-Motor rating and performance curve

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T

400 V, 50 Hz, 3 ~, 2820 r/min

221 2,4 4,9 26,0 0,92 20 No • • •

222 2,4 4,9 26,0 0,92 20 No • • •

226 2,4 4,9 26,0 0,92 20 No • • •

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S

400 V, 50 Hz, 3 ~, 2820 r/min

250 2,4 4,9 26,0 0,92 20 No • •

252 2,4 4,9 26,0 0,92 20 No • •

17

Page 18: Flygt Pumps

C 3060

Dimensional drawingAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Download the drawings from www.flygt.com or contact your ITT Flygt representative for more information.

All dimensions are in mm.

MT, P-installation MT, S-installation

18

Page 19: Flygt Pumps

C 3060

MT, T-installation HT, P-installation

HT, S-installation

19

Page 20: Flygt Pumps

C 3068

C 3068ProductSubmersible pump for pumping clean water, surface water and waste water containing solids or fibred material.

DenominationProduct code 3068.180

Installation F, P

Impeller characteristic HT

Process data Liquid temperature max +40 °C

Depth of immersion max 20 m

The pH of the pumped liquid pH 5,5-14

Liquid density max. 1100 kg/m3

Impeller throughlet See Motor rating table

Motor dataFrequency 50 Hz

Insulation class H (+180 °C)

Voltage variation

- continuously running max ± 5%

- intermittent running max ± 10%

Voltage imbalance between phases max 2%

No. of starts/hour max 15

CableDirect-on-line startSUBCAB® 4G2,5 mm2

4G2,5+2x1,5 mm2

Y/D startSUBCAB® 7G2,5 mm2

Monitoring equipmentThermal contacts opening temperature 125 °C

MaterialImpeller Cast iron

Pump housing Cast iron

Stator housing Cast iron

Shaft Stainless steel

O-rings Fluorinated rubber

Mechanical face seals

Surface TreatmentThe finishing coat is a two pack oxiran ester paint.

WeightSee dimensional drawing.

Option3068.090 Ex. proof design

Warm liquid version on request

Leakage sensor in stator housing FLS

Surface treatment Epoxy treatment

Other cables

Zinc anodes

AccessoriesDischarge connections, adapters, hose connections and other mechanical accessories.

Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables.

See separate booklet or www.flygt.com for further information.

Alternative Inner seal Outer seal

1 Aluminium oxide/Aluminium oxide

Aluminium oxide/Aluminium oxide

2 Aluminium oxide/Aluminium oxide

Aluminium oxide/Corrosion resistant cemented carbide

3 Aluminium oxide/Aluminium oxide

Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide

4 Aluminium oxide/Aluminium oxide

Silicon carbide/ Silicon carbide

20

Page 21: Flygt Pumps

C 3068

HT-Motor rating and performance curve

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

rou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

F P

400 V, 50 Hz, 3 ~, 2700 r/min

251 1,7 3,8 17,0 0,87 34 Yes • •

253 1,7 3,8 17,0 0,87 34 Yes • •

255 1,7 3,8 17,0 0,87 34 Yes • •

230 V, 50 Hz, 1 ~, 2705 r/min

251 2,4 5,3 24,0 0,87 34 Yes • •

253 2,4 5,3 24,0 0,87 34 Yes • •

255 2,4 5,3 24,0 0,87 34 Yes • •

230 V, 50 Hz, 1 ~, 2730 r/min

253 1,5 8,9 28,0 0,99 34 No • •

255 1,5 8,9 28,0 0,99 34 No • •

������

�������

� � � � �� �� ��

��

��

��

��

���

���

���

���

���

���

���

���

���

�� ����

21

Page 22: Flygt Pumps

C 3068

Dimensional drawingAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Download the drawings from www.flygt.com or contact your ITT Flygt representative for more information.

All dimensions are in mm.

HT, F-installation HT, P-installation

22

Page 23: Flygt Pumps

C 3068

HT, P-installation HT, P-installation

23

Page 24: Flygt Pumps

C 3085

C 3085ProductSubmersible pump for pumping clean water, surface water and waste water containing solids or long-fibred material.

DenominationProduct code 3085.182

Installation F, P, S, T, Z

Impeller characteristics LT, MT, HT

Process data Liquid temperature max +40 °C

Depth of immersion max 20 m

The pH of the pumped liquid pH 5,5-14

Liquid density max. 1100 kg/m3

Impeller throughlet See Motor rating table

Motor dataFrequency 50 Hz

Insulation class H (+180 °C)

Voltage variation

- continuously running max ± 5%

- intermittent running max ± 10%

Voltage imbalance between phases max 2%

No. of starts/hour max 15

CableDirect-on-line startSUBCAB® 4G1,5 mm2

4G1,5+2x1,5 mm2

4G2,5 mm2

4G2,5+2x1,5 mm2

Y/D startSUBCAB® 7G2,5 mm2

Monitoring equipmentThermal contacts opening temperature 125 °C

MaterialImpeller Cast iron

Pump housing Cast iron

Stator housing Cast iron

Shaft Stainless steel

O-rings Nitrile rubber

Mechanical face seals

Surface TreatmentAll cast parts are primed with a water-borne primer. The finishing coat is a high-solid two pack paint.

WeightSee dimensional drawing.

Option3085.092 Ex. proof design

3085.280 Stainless steel design

3085.290 Stainless steel/ex proof design

3085.980 Industrial design

Warm liquid version on request

Leakage sensor in stator housing FLS

Leakage sensor in oil housing CLS

Other cables

Surface treatment Epoxy treatment

Zinc anodes

AccessoriesDischarge connections, adapters, hose connections and other mechanical accessories.

Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables.

See separate booklet or www.flygt.com, for further information.

Alternative Inner seal Outer seal

1 Carbon/ Aluminium oxide

Aluminium oxide/ Aluminium oxide

2 Carbon/ Aluminium oxide

Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide

3 Carbon/ Aluminium oxide

Silicon carbide/ Silicon carbide

24

Page 25: Flygt Pumps

C 3085

LT-Motor rating and performance curve

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S

400 V, 50 Hz, 3 ~, 940 r/min

612 0,9 2,9 11 0,65 100 Yes • •

614 0,9 2,9 11 0,65 80 Yes • •

620 0,9 2,9 11 0,65 100 Yes • •

621 0,9 2,9 11 0,65 100 Yes • •

622 0,9 2,9 11 0,65 100 Yes • •

400 V, 50 Hz, 3 ~, 1385 r/min

414 1,3 3,2 13 0,83 80 Yes • •

400 V, 50 Hz, 3 ~, 1395 r/min

412 2,0 5,1 28 0,74 100 Yes • •

414 2,0 5,1 28 0,74 100 Yes • •

������

����

�� ����

� � �� �� �� �� �� �� � ��

���

���

���

���

���

��

���

���

��

��

��

��

���

���

���

���

���

���

25

Page 26: Flygt Pumps

C 3085

������

����

�� ����

� � �� �� �� �� �� ���

��

���

���

���

���

���

���

��

���

���

��

��

��

��

���

���

��

��

��

��

������

����

�� ����

� � � � �� �� � �� ���

��

��

��

��

���

���

���

���

���

���

���

MT-Motor rating and performance curve

HT-Motor rating and performance curve

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

InstallationF P S T Z

400 V, 50 Hz, 3 ~, 940 r/min632 0,9 2,9 11 0,65 76 Yes • • •634 0,9 2,9 11 0,65 76 Yes • • •636 0,9 2,9 11 0,65 76 Yes • • •400 V, 50 Hz, 3 ~, 1385 r/min434 1,3 3,2 13 0,83 76 Yes • • •436 1,3 3,2 13 0,83 76 Yes • • •438 1,3 3,2 13 0,83 64 Yes • • •440 1,3 3,2 13 0,83 64 Yes • • •400 V, 50 Hz, 3 ~, 1430 r/min434 1,4 3,5 22 0,75 76 Yes • •436 1,4 3,5 22 0,75 76 Yes • •438 1,4 3,5 22 0,75 64 Yes • •440 1,4 3,5 22 0,75 64 Yes • •400 V, 50 Hz, 3 ~, 1395 r/min432 2,0 4,6 22 0,83 76 Yes • • •434 2,0 4,6 22 0,83 76 Yes • • •436 2,0 4,6 22 0,83 76 Yes • • •438 2,0 4,6 22 0,83 64 Yes • • •440 2,0 4,6 22 0,83 64 Yes • • •230 V, 50 Hz, 1 ~, 1410 r/min436 0,95 7,2 28 0,86 76 No • • •438 0,95 7,2 28 0,86 64 No • • •440 0,95 7,2 28 0,86 64 No • • •230 V, 50 Hz, 1 ~, 1425 r/min434 1,5 9,4 44 0,90 76 No • • •

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S

400 V, 50 Hz, 3 ~, 2830 r/min

250 2,4 4,7 27 0,92 40 Yes • •

252 2,4 4,7 27 0,92 40 Yes • •

26

Page 27: Flygt Pumps

C 3085

Dimensional drawingAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Download the drawings from www.flygt.com or contact your ITT Flygt representative for more information.

All dimensions are in mm.

LT, P-installation LT, P-installation

27

Page 28: Flygt Pumps

C 3085

LT, S-installation LT, S-installation

MT, F-installation MT, P-installation

28

Page 29: Flygt Pumps

C 3085

MT, P-installation MT, P-installation

MT, S-installation MT, S-installation

29

Page 30: Flygt Pumps

C 3085

MT, T-installation MT, Z-installation

HT, P-installation HT, S-installation

30

Page 31: Flygt Pumps

C 3102

C 3102ProductSubmersible pump for pumping clean water, surface water and waste water containing solids or long-fibred material.

DenominationProduct code 3102.180

Installation P, S, T, Z

Impeller characteristics LT, MT, HT

Process data Liquid temperature max +40 °C

Depth of immersion max 20 m

The pH of the pumped liquid pH 5,5-14

Liquid density max. 1100 kg/m3

Impeller throughlet See Motor rating table

Motor dataFrequency 50 Hz

Insulation class H (+180 °C)

Voltage variation

- continuously running max ± 5%

- intermittent running max ± 10%

Voltage imbalance between phases max 2%

No. of starts/hour max 15

CableDirect-on-line startSUBCAB® 4G2,5 mm2

4G2,5+2x1,5 mm2

Y/D startSUBCAB® 7G2,5+2x1,5 mm2

7G2,5 mm2

Monitoring equipmentThermal contacts opening temperature 125 °C

MaterialImpeller Cast iron

Pump housing Cast iron

Stator housing Cast iron

Shaft Stainless steel

O-rings Nitrile rubber

Mechanical face seals

Surface TreatmentAll cast parts are primed with a water-borne primer. The finishing coat is a high-solid two pack paint.

WeightSee dimensional drawing.

Option3102.090 Ex. proof design

3102.980 Industrial design

Warm liquid version on request

Leakage sensor in stator housing FLS

Leakage sensor in oil housing CLS

Surface treatment Epoxy treatment

Other cables

Zinc anodes

AccessoriesDischarge connections, adapters, hose connections and other mechanical accessories.

Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables.

See separate booklet or www.flygt.com, for further information.

Alternative Inner seal Outer seal

1 Carbon/Aluminium oxide

Aluminium oxide/Corrosion resistant cemented carbide

2 Carbon/Aluminium oxide

Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide

3 Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

Aluminium oxide/Corrosion resistant cemented carbide

4 Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

3

Page 32: Flygt Pumps

C 3102

������

����

�� ����

� �� �� �� � ���

��

���

���

���

���

���

��

��

��

��

��

��

��

������

����

�� ����

� � �� �� �� �� �� �� ��

��

��

������������������

��

��

��

��

��

��

��

��

��

LT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

MT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 1450 r/min

411 2,4 5,1 37 0,83 52 Yes • •

412 2,4 5,1 37 0,83 54 Yes • •

441 2,4 5,1 37 0,83 100 Yes • •

442 2,4 5,1 37 0,83 100 Yes • •

400 V, 50 Hz, 3 ~, 1435 r/min

410 3,1 6,4 37 0,86 55 Yes • •

411 3,1 6,4 37 0,86 52 Yes • •

412 3,1 6,4 37 0,86 54 Yes • •

440 3,1 6,4 37 0,86 100 Yes • •

441 3,1 6,4 37 0,86 100 Yes • •

442 3,1 6,4 37 0,86 100 Yes • •

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 1450 r/min

432 2,4 5,1 37 0,83 76 Yes • •

433 2,4 5,1 37 0,83 76 Yes • •

434 2,4 5,1 37 0,83 76 Yes • •

435 2,4 5,1 37 0,83 76 Yes • •

400 V, 50 Hz, 3 ~, 1435 r/min

430 3,1 6,4 37 0,86 76 Yes • •

432 3,1 6,4 37 0,86 76 Yes • •

433 3,1 6,4 37 0,86 76 Yes • •

434 3,1 6,4 37 0,86 76 Yes • •

435 3,1 6,4 37 0,86 76 Yes • •

4

Page 33: Flygt Pumps

C 3102

HT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S

400 V, 50 Hz, 3 ~, 2870 r/min

252 4,4 8,6 64 0,92 52 Yes • •

254 4,4 8,6 64 0,92 46 Yes • •

������

����

�� ����

� � �� �� �� �� ���

��

��

��

��

���

���

��

��

5

Page 34: Flygt Pumps

C 3102

Dimensional drawingAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Download the drawings from www.flygt.com or contact your ITT Flygt representative for more information.

All dimensions are in mm.

LT, P-installation LT, P-installation

6

Page 35: Flygt Pumps

C 3102

LT, P-installation LT, S-installation

LT, S-installation LT, T-installation

7

Page 36: Flygt Pumps

C 3102

LT, T-installation LT, Z-installation

LT, Z-installation MT, P-installation

8

Page 37: Flygt Pumps

C 3102

MT, S-installation MT, T-installation

MT, Z-installation HT, P-installation

9

Page 38: Flygt Pumps

C 3102

HT, S-installation

10

Page 39: Flygt Pumps

C 3126

C 3126ProductSubmersible pump for pumping sewage water and sludge.

DenominationProduct code 3126.280

Installation P, S, T, Z

Impeller characteristics MT, HT

Process data Liquid temperature max +40 °C

Depth of immersion max 20 m

The pH of the pumped liquid pH 0-14

Liquid density max. 1100 kg/m3

Impeller throughlet See Motor rating table

Motor dataFrequency 50 Hz

Insulation class H (+180 °C)

Voltage variation

- continuously running max ± 5%

- intermittent running max ± 10%

Voltage imbalance between phases max 2%

No. of starts/hour max 15

CableDirect-on-line startSUBCAB® 4G2,5+2x1,5 mm2

Y/D startSUBCAB® 7G2,5 mm2

7G2,5+2x1,5 mm2

7G4+2x1,5 mm2

Monitoring equipmentThermal contacts opening temperature 125 °C

MaterialImpeller Stainless steel

Pump housing Stainless steel

Stator housing Stainless steel

Shaft Stainless steel

O-rings Fluorinated rubber

Mechanical face seals

Surface TreatmentNo treatment.

WeightSee dimensional drawing.

Option3126.290 Ex. proof design

Warm liquid version on request

Leakage sensor in stator housing FLS

Leakage sensor in oil housing CLS

Other cables

AccessoriesDischarge connections, adapters, hose connections and other mechanical accessories.

Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables.

See separate booklet or www.flygt.com, for further information.

Alternative Inner seal Outer seal

1 Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

Silicon carbide/ Silicon carbide

39

Page 40: Flygt Pumps

C 3126

������

����

�� ����

� �� �� �� � �� �� �� ���

��

��

��

��

��

��

��

��

������

����

�� ����

� �� �� �� � ���

��

��

��

��

��

��

���

���

���

���

��

��

��

��

��

��

MT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

HT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 1435 r/min

432 5,3 11 56 0,87 87 Yes • • • •

400 V, 50 Hz, 3 ~, 1440 r/min

430 6,7 14 77 0,86 100 Yes • • • •

432 6,7 14 77 0,86 87 Yes • • • •

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 1435 r/min

461 5,3 11 56 0,87 76 Yes • • • •

462 5,3 11 56 0,87 76 Yes • • • •

400 V, 50 Hz, 3 ~, 1440 r/min

461 6,7 14 77 0,86 76 Yes • • • •

462 6,7 14 77 0,86 76 Yes • • • •

467 6,7 14 77 0,86 76 Yes • • • •

400 V, 50 Hz, 3 ~, 2890 r/min

250 8,0 15 114 0,92 58 Yes • • • •

252 8,0 15 114 0,92 58 Yes • • • •

40

Page 41: Flygt Pumps

C 3126

Dimensional drawingAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).Download the drawings from www.flygt.com or contact your ITT Flygt representative for more information.

All dimensions are in mm.

MT, P-installation MT, S-installation

41

Page 42: Flygt Pumps

C 3126

MT, T-installation MT, Z-installation

HT, P-installation HT, P-installation

42

Page 43: Flygt Pumps

C 3126

HT, S-installation HT, S-installation

HT, T-installation HT, T-installation

43

Page 44: Flygt Pumps

C 3126

HT, Z-installation HT, Z-installation

44

Page 45: Flygt Pumps

C 3127

C 3127ProductSubmersible pump for pumping clean water, surface water and waste water containing solids or long-fibred material.

DenominationProduct code 3127.180

Installation P, S, T, Z

Impeller characteristics LT, MT, HT, SH

Process data Liquid temperature max +40 °C

Depth of immersion max 20 m

The pH of the pumped liquid pH 5,5-14

Liquid density max. 1100 kg/m3

Impeller throughlet See Motor rating table

Motor dataFrequency 50 Hz

Insulation class H (+180 °C)

Voltage variation

- continuously running max ± 5%

- intermittent running max ± 10%

Voltage imbalance between phases max 2%

No. of starts/hour max 15

CableDirect-on-line startSUBCAB® 4G2,5 mm2

4G2,5+2x1,5 mm2

4G4 mm2

4G4+2x1,5 mm2

Y/D startSUBCAB® 7G2,5 mm2

7G2,5+2x1,5 mm2

7G4 mm2

7G4+2x1,5 mm2

Monitoring equipmentThermal contacts opening temperature 125 °C

MaterialImpeller Cast iron

Pump housing Cast iron

Stator housing Cast iron

Shaft Stainless steel

O-rings Nitrile rubber

Mechanical face seals

Surface TreatmentAll cast parts are primed with a water-borne primer. The finishing coat is a high-solid two pack paint.

WeightSee dimensional drawing.

Option3127.090 Ex. proof design

3127.980 Industrial design

Warm liquid version on request

Leakage sensor in stator housing FLS

Leakage sensor in oil housing CLS

Surface treatment Epoxy treatment

Other cables

Zinc anodes

AccessoriesDischarge connections, adapters, hose connections and other mechanical accessories.

Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables.

See separate booklet or www.flygt.com, for further information.

Alternative Inner seal Outer seal

1 Carbon/Aluminium oxide

Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

2 Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

Silicone carbide/ Silicone carbide

3 Carbon/Aluminium oxide

Silicone carbide/ Silicone carbide

4 Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

45

Page 46: Flygt Pumps

C 3127

LT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 1435 r/min

412 4,0 8,3 56 0,84 76 Yes • •

442 4,0 8,3 56 0,84 100 Yes • •

400 V, 50 Hz, 3 ~, 1445 r/min

411 4,7 9,6 56 0,86 76 Yes • •

412 4,7 9,6 56 0,86 76 Yes • •

442 4,7 9,6 56 0,86 100 Yes • •

400 V, 50 Hz, 3 ~, 1460 r/min

411 4,7 9,6 56 0,86 76 Yes • •

411 4,7 10 77 0,81 76 Yes • •

412 4,7 9,6 56 0,86 76 Yes • •

412 4,7 10 77 0,81 76 Yes • •

442 4,7 9,6 56 0,86 100 Yes • •

442 4,7 10 77 0,81 100 Yes • •

400 V, 50 Hz, 3 ~, 2900 r/min

410 5,9 12 77 0,86 76 Yes • •

411 5,9 12 77 0,86 76 Yes • •

412 5,9 12 77 0,86 76 Yes • •

441 5,9 12 77 0,86 107 Yes • •

442 5,9 12 77 0,86 100 Yes • •

������

����

�� ����

� �� � �� �� ����

��

��

��

��

��

��

��

��

��

46

Page 47: Flygt Pumps

C 3127

MT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~,1435 r/min

432 4,0 8,3 56 0,84 87 Yes • •

433 4,0 8,3 56 0,84 28 Yes • •

434 4,0 8,3 56 0,84 80 Yes • •

436 4,0 8,3 56 0,84 100 Yes • •

400 V, 50 Hz, 3 ~, 1445 r/min

431 4,7 9,6 56 0,86 90 Yes • •

432 4,7 9,6 56 0,86 87 Yes • •

433 4,7 9,6 56 0,86 82 Yes • •

434 4,7 9,6 56 0,86 80 Yes • •

436 4,7 9,6 56 0,86 100 Yes • •

400 V, 50 Hz, 3 ~, 1460 r/min

431 4,7 10 77 0,81 90 Yes • •

432 4,7 10 77 0,81 87 Yes • •

433 4,7 10 77 0,81 82 Yes • •

434 4,7 10 77 0,81 80 Yes • •

436 4,7 10 77 0,81 100 Yes • •

400 V, 50 Hz, 3 ~, 1450 r/min

430 5,9 12 77 0,84 100 Yes • •

431 5,9 12 77 0,84 90 Yes • •

432 5,9 12 77 0,84 87 Yes • •

433 5,9 12 77 0,84 82 Yes • •

434 5,9 12 77 0,84 80 Yes • •

435 5,9 12 77 0,84 100 Yes • •

436 5,9 12 77 0,84 100 Yes • •

������

����

�� ����

� �� �� �� � �� �� ���

��

��

��

��

��

��

��

��

��

��

��

��

��

��

��

��

47

Page 48: Flygt Pumps

C 3127

HT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 1435 r/min

483 4,0 8,3 56 0,84 76 Yes • •

484 4,0 8,3 56 0,84 76 Yes • •

485 4,0 8,3 56 0,84 76 Yes • •

400 V, 50 Hz, 3 ~, 1445 r/min

483 4,7 9,6 56 0,86 76 Yes • •

484 4,7 9,6 56 0,86 76 Yes • •

485 4,7 9,6 56 0,86 76 Yes • •

400 V, 50 Hz, 3 ~, 1450 r/min

480 5,9 12 77 0,84 76 Yes • •

481 5,9 12 77 0,84 76 Yes • •

483 5,9 12 77 0,84 76 Yes • •

484 5,9 12 77 0,84 76 Yes • •

485 5,9 12 77 0,84 76 Yes • •

400 V, 50 Hz, 3 ~, 1460 r/min

483 4,7 10 77 0,81 76 Yes • •

484 4,7 10 77 0,81 76 Yes • •

485 4,7 10 77 0,81 76 Yes • •

400 V, 50 Hz, 3 ~, 2900 r/min

250 7,4 14 114 0,91 58 Yes • •

������

����

�� ����

� �� �� �� � ���

��

��

��

��

��

��

���

���

��

��

��

��

��

��

��

��

48

Page 49: Flygt Pumps

C 3127

SH-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S

400 V, 50 Hz, 3 ~, 2900 r/min

255 7,4 14 114 0,91 40 Yes • •

256 7,4 14 114 0,91 40 Yes • •

257 7,4 14 114 0,91 40 Yes • •

258 7,4 14 114 0,91 40 Yes • •

259 7,4 14 114 0,91 40 Yes • •

������

����

�� ����

� � �� �� �� ���

��

��

��

��

��

���

���

���

���

���

���

���

���

���

���

49

Page 50: Flygt Pumps

C 3127

Dimensional drawingAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Download the drawings from www.flygt.com or contact your ITT Flygt representative for more information.

All dimensions are in mm.

LT, P-installation LT, P-installation

50

Page 51: Flygt Pumps

C 3127

LT, S-installation LT, T-installation

LT, Z-installation MT, P-installation

51

Page 52: Flygt Pumps

C 3127

MT, P-installation MT, P-installation

MT, S-installation MT, S-installation

52

Page 53: Flygt Pumps

C 3127

MT, T-installation MT, T-installation

MT, Z-installation MT, Z-installation

53

Page 54: Flygt Pumps

C 3127

HT, P-installation HT, P-installation

HT, P-installation HT, P-installation

54

Page 55: Flygt Pumps

C 3127

HT, S-installation HT, S-installation

HT, T-installation HT, T-installation

55

Page 56: Flygt Pumps

C 3127

HT, Z-installation HT, Z-installation

SH, P-installation SH, S-installation

56

Page 57: Flygt Pumps

C 3140

C 3140ProductSubmersible pump for pumping clean water, surface water and waste water containing solids or long-fibred material.

DenominationProduct code 3140.180

Installation P, S

Impeller characteristics LT, MT, HT,

Process data Liquid temperature max +40 °C

Depth of immersion max 20 m

The pH of the pumped liquid pH 5,5-14

Liquid density max. 1100 kg/m3

Impeller throughlet See Motor rating table

Motor dataFrequency 50 Hz

Insulation class H (+180 °C)

Voltage variation

- continuously running max ± 5%

- intermittent running max ± 10%

Voltage imbalance between phases max 2%

No. of starts/hour max 15

CableDirect-on-line startSUBCAB® 4G2,5+2x1,5 mm2

4G4+2x1,5 mm2

4G6+2x1,5 mm2

Y/D startSUBCAB® 7G2,5+2x1,5 mm2

7G4+2x1,5 mm2

7G6+2x1,5 mm2

Monitoring equipmentThermal contacts opening temperature 125 °C

MaterialImpeller Cast iron

Pump housing Cast iron

Stator housing Cast iron

Shaft Stainless steel

O-rings Nitrile rubber

Mechanical face seals

Surface TreatmentAll cast parts are primed with a water-borne primer. The finishing coat is a high-solid two pack paint.

WeightSee dimensional drawing.

Option3140.090 Ex. proof design

3140.980 Industrial design

Surface treatment Epoxy treatment

Leakage sensor in stator housing FLS

Leakage sensor in oil housing CLS

Other cables

Zinc anodes

AccessoriesDischarge connections, adapters, hose connections and other mechanical accessories.

Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables.

See separate booklet or www.flygt.com, for further information.

Alternative Inner seal Outer seal

1 Carbon/Corrosion resistant cemented carbide

Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

2 Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

57

Page 58: Flygt Pumps

C 3140

������

����

�� ����

� �� � �� �� ��� ��� �� ��� ����

��

��

���

���

���

���

��

��

������

����

�� ����

� �� �� �� � �� �� �� �� ���

��

��

��

��

��

��

��

��

��

LT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

MT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S

400 V, 50 Hz, 3 ~, 955 r/min

610 8,8 18 87 0,87 102 Yes • •

612 8,8 18 87 0,87 102 Yes • •

614 8,8 18 87 0,87 82 Yes • •

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S

400 V, 50 Hz, 3 ~, 1455 r/min

432 9,0 19 116 0,81 102 Yes • •

434 9,0 19 116 0,81 102 Yes • •

436 9,0 19 116 0,81 93 Yes • •

58

Page 59: Flygt Pumps

C 3140

HT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S

400 V, 50 Hz, 3 ~, 1455 r/min

452 9,0 19 116 0,81 76 Yes • •

454 9,0 19 116 0,81 76 Yes • •

������

����

�� ����

� �� �� �� � �� ���

��

��

��

��

��

��

��

��

��

59

Page 60: Flygt Pumps

C 3140

Dimensional drawingAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Download the drawings from www.flygt.com or contact your ITT Flygt representative for more information.

All dimensions are in mm.

LT, P-installation LT, P-installation

60

Page 61: Flygt Pumps

C 3140

LT, S-installation MT, P-installation

MT, S-installation HT, P-installation

61

Page 62: Flygt Pumps

C 3140

HT, P-installation HT, S-installation

HT, S-installation

62

Page 63: Flygt Pumps

C 3152

C 3152ProductSubmersible pump for pumping clean water, surface water and waste water containing solids or long-fibred material.

DenominationProduct code 3152.181

Installation P, S, T, Z

Impeller characteristics LT, MT, HT, SH

Process data Liquid temperature max +40 °C

Depth of immersion max 20 m

The pH of the pumped liquid pH 5,5-14

Liquid density max. 1100 kg/m3

Impeller throughlet See Motor rating table

Motor dataFrequency 50 Hz

Insulation class H (+180 °C)

Voltage variation

- continuously running max ± 5%

- intermittent running max ± 10%

Voltage imbalance between phases max 2%

No. of starts/hour max 15

CableDirect-on-line startSUBCAB® 4G4+2x1,5 mm2

4G6+2x1,5 mm2

4G10+2x1,5 mm2

Y/D startSUBCAB® 7G2,5+2x1,5 mm2

7G4+2x1,5 mm2

7G6+2x1,5 mm2

Monitoring equipmentThermal contacts opening temperature 125 °C

MaterialImpeller Cast iron

Pump housing Cast iron

Stator housing Cast iron

Shaft Stainless steel

O-rings Nitrile rubber

Mechanical face seals

Surface TreatmentAll cast parts are primed with a water-borne primer. The finishing coat is a high-solid two pack paint.

WeightSee dimensional drawing.

Option3152.091 Ex. proof design

3152.980 Industrial design

Warm liquid version on request

Leakage sensor in stator housing FLS

Leakage sensor in oil housing CLS

Surface treatment Epoxy treatment

Other cables

Zinc anodes

AccessoriesDischarge connections, adapters, hose connections and other mechanical accessories.

Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables.

See separate booklet or www.flygt.com, for further information.

Alternative Inner seal Outer seal

1 Corrosion resistant cemented carbide/Carbon

Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

2 Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

63

Page 64: Flygt Pumps

C 3152

������

����

�� ����

� �� ��� ��� ��� ����

��

��

���

���

���

���

���

���

���

���

��

��

������

����

�� ����

� �� � �� �� ����

��

��

��

��

��

��

��

��

��

��

��

��

��

��

��

LT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

MT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 955 r/min

616 8,8 18 87 0,87 616 Yes • • • •

618 8,8 18 87 0,87 618 Yes • • • •

620 8,8 18 87 0,87 620 Yes • • • •

622 8,8 18 87 0,87 622 Yes • • • •

624 8,8 18 87 0,87 624 Yes • • • •

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 1455 r/min

432 9,0 19 116 0,81 100 Yes • • • •

434 9,0 19 116 0,81 100 Yes • • • •

436 9,0 19 116 0,81 93 Yes • • • •

400 V, 50 Hz, 3 ~, 1450 r/min

430 13,5 27 162 0,83 100 Yes • • • •

431 13,5 27 162 0,83 100 Yes • • • •

432 13,5 27 162 0,83 100 Yes • • • •

434 13,5 27 162 0,83 100 Yes • • • •

436 13,5 27 162 0,83 93 Yes • • • •

64

Page 65: Flygt Pumps

C 3152

������

����

�� ����

� �� �� �� � �� �� ���

��

��

��

��

��

��

��

��

��

��

��

������

����

�� ����

� � �� �� �� ���

��

��

��

��

��

��

��

��

����

���

��

��

���

���

���

���

���

���

���

���

���

���

HT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

SH-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 1455 r/min

454 9,0 19 116 0,81 76 Yes • • • •

400 V, 50 Hz, 3 ~, 1450 r/min

450 13,5 27 162 0,83 76 Yes • • • •

452 13,5 27 162 0,83 76 Yes • • • •

454 13,5 27 162 0,83 76 Yes • • • •

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 2920 r/min

263 15 28 229 0,89 40 Yes • • • •

264 15 28 229 0,89 40 Yes • • • •

265 15 28 229 0,89 40 Yes • • • •

266 15 28 229 0,89 40 Yes • • • •

267 15 28 229 0,89 40 Yes • • • •

268 15 28 229 0,89 40 Yes • • • •

269 15 28 229 0,89 40 Yes • • • •

65

Page 66: Flygt Pumps

C 3152

Dimensional drawingAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Download the drawings from www.flygt.com or contact your ITT Flygt representative for more information.

All dimensions are in mm.

LT, P-installation LT, P-installation

66

Page 67: Flygt Pumps

C 3152

LT, S-installation LT, T-installation

LT, Z-installation MT, P-installation

67

Page 68: Flygt Pumps

C 3152

MT, P-installation MT, S-installation

MT, S-installation MT, T-installation

68

Page 69: Flygt Pumps

C 3152

MT, Z-installation HT, P-installation

HT, P-installation HT, S-installation

69

Page 70: Flygt Pumps

C 3152

HT, S-installation HT, S-installation

HT, T-installation HT, T-installation

70

Page 71: Flygt Pumps

C 3152

HT, Z-installation SH, P-installation

HT, S-installation SH, T-installation

71

Page 72: Flygt Pumps

C 3170

C 3170ProductSubmersible pump for pumping clean water, surface water and waste water containing solids or long-fibred material.

DenominationProduct code 3170.180

Installation P, S, T, Z

Impeller characteristics LT, MT, HT

Process data Liquid temperature max +40 °C

Depth of immersion max 20 m

The pH of the pumped liquid pH 5,5-14

Liquid density max. 1100 kg/m3

Impeller throughlet See Motor rating table

Motor dataFrequency 50 Hz

Insulation class H (+180 °C)

Voltage variation

- continuously running max ± 5%

- intermittent running max ± 10%

Voltage imbalance between phases max 2%

No. of starts/hour max 15

CableDirect-on-line startSUBCAB® 4G4+2x1,5 mm2

4G6+2x1,5 mm2

SUBCAB® 4G10+2x1,5 mm2

4G16+2x1,5 mm2

4G25 mm2

4G25+2x1,5 mm2

Y/D startSUBCAB® 7G2,5+2x1,5 mm2

2x7G2,5+2x1,5 mm2

2x7G4+2x1,5 mm2

2x7G6+2x1,5 mm2

Monitoring equipmentThermal contacts opening temperature 125 °C

MaterialImpeller Cast iron

Pump housing Cast iron

Stator housing Cast iron

Shaft Stainless steel or carbon steel

O-rings Nitrile rubber

Mechanical face seals

Surface TreatmentAll cast parts are primed with a water-borne primer. The finishing coat is a high-solid two pack paint.

WeightSee dimensional drawing.

Option3170.090 Ex. proof design

3170.980 Industrial design

Warm liquid version on request

Leakage sensor in stator housing FLS

Leakage sensor in oil housing CLS

Surface treatment Epoxy treatment

Other cables

Zinc anodes

AccessoriesDischarge connections, adapters, hose connections and other mechanical accessories.

Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables.

See separate booklet or www.flygt.com, for further information.

Alternative Inner seal Outer seal

1 Corrosion resistant cemented carbide/Carbon

Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

2 Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

72

Page 73: Flygt Pumps

C 3170

������

����

�� ����

� �� ��� ��� ��� ��� ����

��

��

��

��

��

��

���

���

���

���

���

���

��

��

������

����

�� ����

� �� � �� �� ����

��

��

��

��

��

��

�����������

��

LT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

MT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 970 r/min

601 15 32 221 0,80 102 Yes • • • •

602 15 32 221 0,80 102 Yes • • • •

603 15 32 221 0,80 102 Yes • • • •

604 15 32 221 0,80 102 Yes • • • •

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 1460 r/min

440 22,0 42 300 0,87 100 Yes • • • •

441 22,0 42 300 0,87 100 Yes • • • •

73

Page 74: Flygt Pumps

C 3170

HT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 1460 r/min

460 22,0 42 300 0,87 77 Yes • • • •

461 22,0 42 300 0,87 77 Yes • • • •

462 22,0 42 300 0,87 77 Yes • • • •

������

����

�� ����

� �� �� �� � �� �� �� ���

��

��

��

��

��

��

��

��

��

��

��

��

��

��

��

��

74

Page 75: Flygt Pumps

C 3170

Dimensional drawingAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Download the drawings from www.flygt.com or contact your ITT Flygt representative for more information.

All dimensions are in mm.

LT, P-installation LT, P-installation

75

Page 76: Flygt Pumps

C 3170

LT, S-installation LT, T-installation

LT, T-installation LT, Z-installation

76

Page 77: Flygt Pumps

C 3170

MT, P-installation MT, P-installation

MT, S-installation MT, S-installation

77

Page 78: Flygt Pumps

C 3170

MT, S-installation MT, S-installation

MT, T-installation MT, Z-installation

78

Page 79: Flygt Pumps

C 3170

HT, P-installation HT, P-installation

HT, S-installation HT, T-installation

79

Page 80: Flygt Pumps

C 3170

HT, T-installation HT, Z-installation

80

Page 81: Flygt Pumps

C 3201

C 3201ProductSubmersible pump for pumping clean water, surface water and waste water containing solids or long-fibred material.

DenominationProduct code 3201.180

Installation P, S, T, Z

Impeller characteristics LT, MT, HT, SH

Process data Liquid temperature max +40 °C

Depth of immersion max 20 m

The pH of the pumped liquid pH 5,5-14

Liquid density max. 1100 kg/m3

Impeller throughlet See Motor rating table

Motor dataFrequency 50 Hz

Insulation class H (+180 °C)

Voltage variation

- continuously running max ± 5%

- intermittent running max ± 10%

Voltage imbalance between phases max 2%

No. of starts/hour max 15

CableDirect-on-line startSUBCAB® 4G10+2x1,5 mm2

4G16+2x1,5 mm2

SUBCAB® 4G25 mm2

4G25+2x1,5 mm2

4G35 mm2

4G35+2x1,5 mm2

Y/D startSUBCAB® 2x4G10+2x1,5 mm2

7G6+2x1,5 mm2

Monitoring equipmentThermal contacts opening temperature 125 °C

MaterialImpeller Cast iron

Pump housing Cast iron

Stator housing Cast iron

Shaft Carbon steel

O-rings Nitrile rubber

Mechanical face seals

Surface TreatmentAll cast parts are primed with a water-borne primer. The finishing coat is a high-solid two pack paint.

WeightSee dimensional drawing.

Option3201.091 Ex. proof design

3201.280 Stainless steel design

3201.980 Industrial design

3201.290 Stainless steel/Ex proof design

Warm liquid version on request

Leakage sensor in stator housing FLS

Leakage sensor in oil housing CLS

Surface treatment Epoxy treatment

Other cables

Zinc anodes

AccessoriesDischarge connections, adapters, hose connections and other mechanical accessories.

Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables.

See separate booklet or www.flygt.com, for further information.

Alternative Inner seal Outer seal

1 Carbon/Corrosion resistant cemented carbide

Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

2 Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

81

Page 82: Flygt Pumps

C 3201

������

����

�� ����

� �� ��� ��� ��� ��� ��� ��� ���

��

��

��

��

��

��

��

��

��

���

���

���

���

���

���

���

���

���

���

������

����

�� ����

� � �� ��� ��� ����

��

��

��

��

��

��

��

���

���

���

���

��

��

���

���

���

���

���

���

���

���

LT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

MT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 970 r/min (4-pole), 1460 r/min (6-pole)

624 22,0 45 300 0,82 102 Yes • • • •

625 22,0 45 300 0,82 102 Yes • • • •

626 22,0 45 300 0,82 102 Yes • • • •

627 22,0 45 300 0,82 102 Yes • • • •

628 22,0 45 300 0,82 102 Yes • • • •

629 22,0 45 300 0,82 102 Yes • • • •

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le Installation

P S T Z

400 V, 50 Hz, 3 ~, 970 r/min (4-pole), 1460 r/min (6-pole)

630 22,0 45 300 0,82 84 Yes • • • •

632 22,0 45 300 0,82 84 Yes • • • •

634 22,0 45 300 0,82 84 Yes • • • •

635 22,0 45 300 0,82 84 Yes • • • •

636 22,0 45 300 0,82 84 Yes • • • •

637 22,0 45 300 0,82 84 Yes • • • •

638 22,0 45 300 0,82 84 Yes • • • •

82

Page 83: Flygt Pumps

C 3201

������

����

�� ����

� �� � �� �� ��� ����

��

��

��

��

��

��

�����������

��

��

��

��

��

��

��

��

��

��

��

��

������

����

�� ����

� �� �� �� � �� ���

��

��

��

��

��

��

��

��

��

��

���

���

��

��

���

���

HT-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

SH-Motor rating and performance curve

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 970 r/min (4-pole), 1460 r/min (6-pole)

452 22 42 300 0,87 77 Yes • • • •

457 22 42 300 0,87 100 Yes • • • •

400 V, 50 Hz, 3 ~, 1455 r/min (4-pole), 2970 r/min (2-pole)

450 30 56 365 0,88 77 Yes • • • •

452 30 56 365 0,88 77 Yes • • • •

455 30 56 365 0,88 100 Yes • • • •

456 30 56 365 0,88 100 Yes • • • •

457 30 56 365 0,88 100 Yes • • • •

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 1455 r/min (4-pole), 2970 r/min (2-pole)

263 30 52 385 0,94 76 Yes • • • •

264 30 52 385 0,94 76 Yes • • • •

265 30 52 385 0,94 76 Yes • • • •

83

Page 84: Flygt Pumps

C 3201

Dimensional drawingAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Download the drawings from www.flygt.com or contact your ITT Flygt representative for more information.

All dimensions are in mm.

LT, P-installation LT, P-installation

84

Page 85: Flygt Pumps

C 3201

LT, S-installation LT, T-installation

LT, Z-installation MT, P-installation

85

Page 86: Flygt Pumps

C 3201

MT, S-installation MT, T-installation

MT, Z-installation HT, P-installation

86

Page 87: Flygt Pumps

C 3201

HT, P-installation HT, S-installation

HT, T-installation HT, Z-installation

87

Page 88: Flygt Pumps

C 3201

SH, P-installation SH, S-installation

SH, T-installation

88

Page 89: Flygt Pumps

C 3300

C 3300ProductSubmersible pump for pumping clean water, surface water and waste water containing solids or long-fibred material.

DenominationProduct code 3300.181

Product code 3300/605

Product code 3300/665

Installation P, S, T, Z

Impeller characteristics

Process data Liquid temperature max +40 °C

Depth of immersion max 20 m

The pH of the pumped liquid pH 5,5-14

Liquid density max. 1100 kg/m3

Impeller throughlet See Motor rating table

Motor dataFrequency 50 Hz

Insulation class H (+180 °C)

Voltage variation

- continuously running max ± 5%

- intermittent running max ± 10%

Voltage imbalance between phases max 2%

No. of starts/hour max 15

CableDirect-on-line start3300.181

SUBCAB® 4G10+2x1,5 mm2

4G16+2x1,5 mm2

4G25 mm2

4G25+2x1,5 mm2

4G35+2x1,5 mm2

3300/6XX

SUBCAB® To be dimensioned by ITT Flygt

Y/D start3300.181

SUBCAB® 2x4G10+2x1,5 mm2

2x4G16+2x1,5 mm2

2x4G25+2x1,5 mm2

2x4G35+2x1,5 mm2

3300/6XX

SUBCAB® To be dimensioned by ITT Flygt

Monitoring equipmentThermal contacts opening temperature 125 °C

Leakage sensor in stator housing FLS

Leakage sensor in junction box FLS

Analogue temperature sensor in main bearing Pt100

MaterialImpeller Cast iron

Pump housing Cast iron

Stator housing Cast iron

Shaft Carbon steel

O-rings Nitrile rubber

Mechanical face seals

Surface TreatmentAll cast parts are primed with a water-borne primer. The finishing coat is a high-solid two pack paint.

WeightSee dimensional drawing.

Product code Characteristics

3300.181 LT, MT, HT

3300/6XX LT, HT

Alternative Inner seal Outer seal

1 Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

89

Page 90: Flygt Pumps

C 3300

Option3300.091 Ex. proof design

3300/615 Ex. proof design

3300/675 Ex. proof design

3300.280 Stainless steel design

3300.980 Industrial design

Leakage sensor in stator housing FLS

Leakage sensor in oil housing CLS

Surface treatment Epoxy treatment

Other cables

Zinc anodes

3300/6XX

Analogue temperature sensor in stator winding Pt100

Analogue temperature sensor in support bearing Pt100

AccessoriesDischarge connections, adapters, hose connections and other mechanical accessories.

Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables.

See separate booklet or www.flygt.com, for further information.

90

Page 91: Flygt Pumps

C 3300

������

����

�� ����

� ��� ��� ��� �� ����

��

��

��

��

��

��

��

���

���

���

��

��

���

���

���

���

���

���

���

���

���

���

������

���

���

���

100 200 300 400 500 600 700

2

0

468

101214161820222426283032343638

Q l/s

H m

601

LT-Motor rating and performance curve3300.181

Y/D starting current is approximately 1/3 of D starting current.

3300/605 and 3300/665

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 730 r/min

804 27 56 293 0,8 102 Yes • • • •

805 27 56 293 0,8 102 Yes • • • •

806 27 56 293 0,8 102 Yes • • • •

807 27 56 293 0,8 102 Yes • • • •

808 27 56 293 0,8 102 Yes • • • •

809 27 56 293 0,8 102 Yes • • • •

400 V, 50 Hz, 3 ~, 730 r/min

801 37 77 380 0,80 102 Yes • • • •

802 37 77 380 0,80 102 Yes • • • •

803 37 77 380 0,80 102 Yes • • • •

804 37 77 380 0,80 102 Yes • • • •

805 37 77 380 0,80 102 Yes • • • •

806 37 77 380 0,80 102 Yes • • • •

807 37 77 380 0,80 102 Yes • • • •

808 37 77 380 0,80 102 Yes • • • •

809 37 77 380 0,80 102 Yes • • • •

400 V, 50 Hz, 3 ~, 975 r/min

620 44 82 515 0,88 102 Yes • • • •

Cu

rve/

Imp

elle

r N

o

Dri

ve u

nit

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 985 r/min

601 605 58 118 660 0,78 Yes • • • •

601 665 75 150 835 0,79 Yes • • • •

601 665 90 185 1160 0,76 Yes • • • •

91

Page 92: Flygt Pumps

C 3300

MT-Motor rating and performance curve3300.181

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 975 r/min

636 34 65 475 0,87 176 Yes • • • •

638 34 65 475 0,87 150 Yes • • • •

640 34 65 475 0,87 134 Yes • • • •

642 34 65 475 0,87 100 Yes • • • •

644 34 65 475 0,87 100 Yes • • • •

646 34 65 475 0,87 100 Yes • • • •

648 34 65 475 0,87 100 Yes • • • •

400 V, 50 Hz, 3 ~, 975 r/min

632 44 82 515 0,88 190 Yes • • • •

636 44 82 515 0,88 176 Yes • • • •

638 44 82 515 0,88 150 Yes • • • •

640 44 82 515 0,88 134 Yes • • • •

641 44 82 515 0,88 100 Yes • • • •

642 44 82 515 0,88 100 Yes • • • •

644 44 82 515 0,88 100 Yes • • • •

646 44 82 515 0,88 100 Yes • • • •

648 44 82 515 0,88 100 Yes • • • •

������

����

�� ����

� �� ��� ��� ��� ��� ��� ����

��

��

��

��

��

��

��

��

���

���

���

���

���

���

��

��

��

��

��

��

��

��

��

��

92

Page 93: Flygt Pumps

C 3300

������

����

�� ����

� �� � �� �� ��� ��� �� ����

��

��

��

��

��

��

��

��

��

��

��

��

��

��

��

��

��

��

��

��

��

��

��

��

��

20 40 60 80 100 120 140 160

48

1216202428323640444852566064

0

460

Q l/s

H m

HT-Motor rating and performance curve3300.181

Y/D starting current is approximately 1/3 of D starting current.

3300/605

Y/D starting current is approximately 1/3 of D starting current.

Cu

rve/

Imp

elle

r N

o

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Imp

elle

r th

ou

gh

let,

mm

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 1475 r/min

454 40 78 490 0,82 76 Yes • • • •

464 40 78 490 0,82 76 Yes • • • •

465 40 78 490 0,82 76 Yes • • • •

466 40 78 490 0,82 76 Yes • • • •

467 40 78 490 0,82 76 Yes • • • •

468 40 78 490 0,82 76 Yes • • • •

400 V, 50 Hz, 3 ~, 1475 r/min

452 54 100 535 0,85 90 Yes • • • •

454 54 100 535 0,85 76 Yes • • • •

460 54 100 535 0,85 76 Yes • • • •

461 54 100 535 0,85 76 Yes • • • •

462 54 100 535 0,85 76 Yes • • • •

463 54 100 535 0,85 76 Yes • • • •

464 54 100 535 0,85 76 Yes • • • •

465 54 100 535 0,85 76 Yes • • • •

466 54 100 535 0,85 76 Yes • • • •

467 54 100 535 0,85 76 Yes • • • •

468 54 100 535 0,85 76 Yes • • • •

Cu

rve/

Imp

elle

r N

o

Dri

ve u

nit

Rat

ed p

ow

er, k

W

Rat

ed c

urr

ent,

A

Sta

rtin

g c

urr

ent,

A

Po

wer

fac

tor

cos

ϕ

Ex

pro

of

vers

ion

ava

ilab

le

Installation

P S T Z

400 V, 50 Hz, 3 ~, 1480 r/min

460 605 70 127 800 0,86 Yes • • • •

93

Page 94: Flygt Pumps

C 3300

Dimensional drawingAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Download the drawings from www.flygt.com or contact your ITT Flygt representative for more information.

All dimensions are in mm.

LT, P-installation LT, P-installation

94

Page 95: Flygt Pumps

C 3300

LT, P-installation LT, S-installation

LT, S-installation LT, S-installation

95

Page 96: Flygt Pumps

C 3300

LT, T-installation LT, T-installation

LT, T-installation LT, Z-installation

96

Page 97: Flygt Pumps

C 3300

LT, Z-installation LT, Z-installation

MT, P-installation MT, S-installation

97

Page 98: Flygt Pumps

C 3300

MT, T-installation MT, T-installation

MT, Z-installation MT, Z-installation

98

Page 99: Flygt Pumps

C 3300

HT, P-installation HT, P-installation

HT, P-installation HT, S-installation

99

Page 100: Flygt Pumps

C 3300

HT, S-installation HT, S-installation

HT, S-installation HT, S-installation

100

Page 101: Flygt Pumps

C 3300

HT, S-installation HT, T-installation

HT, T-installation HT, T-installation

101

Page 102: Flygt Pumps

C 3300

HT, Z-installation HT, Z-installation

HT, Z-installation

102

Page 103: Flygt Pumps
Page 104: Flygt Pumps

www.flygt.com

C30

00.5

0Hz.

05.0

1.E

N.F

IN.1

0.03

© IT

T F

lygt

AB

89

41 0

8