flexi wcdma bts optional items description
TRANSCRIPT
-
Flexi WCDMA BTS Optional ItemsDescription
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 1 (83)
Nokia Siemens Networks WCDMA RAN, Rel.RU10, System Library, v. 2
-
The information in this document is subject to change without notice and describes only theproduct defined in the introduction of this documentation. This documentation is intended for theuse of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted inany form or means without the prior written permission of Nokia Siemens Networks. Thedocumentation has been prepared to be used by professional and properly trained personnel,and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomescustomer comments as part of the process of continuous development and improvement of thedocumentation.
The information or statements given in this documentation concerning the suitability, capacity, orperformance of the mentioned hardware or software products are given as is and all liabilityarising in connection with such hardware or software products shall be defined conclusively andfinally in a separate agreement between Nokia Siemens Networks and the customer. However,Nokia Siemens Networks has made all reasonable efforts to ensure that the instructionscontained in the document are adequate and free of material errors and omissions. NokiaSiemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues whichmay not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NOEVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THISDOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL,DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUTNOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESSOPPORTUNITY OR DATA, THAT MAYARISE FROM THE USE OF THIS DOCUMENT OR THEINFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights andother intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark ofNokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners,and they are mentioned for identification purposes only.
Copyright Nokia Siemens Networks 2009. All rights reserved.
2 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
Contents
Contents 3
Summary of changes 5
1 Flexi Mounting Kit for Floor, Wall and Pole (FMFA) description 7
2 Pole Mounting Kit (VMPB) description 11
3 Flexi Mounting Auxiliary Bracket (FMAA) description 13
4 Flexi Pole Installation Kit (FPIA) description 15
5 Flexi Pole Mounting Kit (FPKA) description 17
6 Flexi Mounting Covers for Back and Front (FMCA and FMCB)description 23
7 Flexi System External Alarm (FSEB) description 277.1 Flexi System External Alarm Box (FSEB) operation 277.2 Flexi System External Alarm (FSEB) dimensions and weight 277.3 Flexi System External Alarm (FSEB) interfaces 288 Flexi System External OVP (FSEC) description 31
9 Flexi Power Module (FPMA) and sub-modules (FPAA and FPBA)description 35
9.1 Flexi Power Module (FPMA) and sub-modules (FPAA and FPBA)operation 35
9.2 Flexi Power Module (FPMA) dimensions and weight 379.3 Flexi Power Module (FPMA) and sub-module (FPAA and FPBA)
interfaces 389.4 Flexi power sub-module (FPAA and FPBA) LED indications 4010 Flexi Power DC/DC Module (FPDA) description 4310.1 Flexi Power DC/DC Module (FPDA) operation 4310.2 Flexi Power DC/DC Module (FPDA) dimensions and weight 4410.3 Flexi Power DC/DC Module (FPDA) interfaces 4510.4 Flexi Power DC/DC Module (FPDA) LED indications 4611 Flexi Power AC/DC sub-module (FPAB) description 47
12 Flexi Cabinet for Indoor (FCIA) description 5112.1 FCIA cabinet construction 5112.2 FCIA optional items 5212.3 FCIA dimensions and weight 53
13 Flexi Cabinet for Outdoor (FCOA) description 5513.1 Flexi Cabinet for Outdoor (FCOA) construction 55
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 3 (83)
Contents
-
13.2 FCOA optional items 5613.3 Flexi Cabinet for Outdoor (FCOA) dimensions and weight 6014 Flexi Mounting Shield (FMSA and FMSB) description 6314.1 Flexi Mounting Shield (FMSA and FMSB) operation and construction 6314.2 Flexi Mounting Shield (FMSA and FMSB) dimensions and weights 6615 Flexi Mounting Kit Vertical for 2G (FMUA) description 6715.1 Flexi Mounting Kit Vertical for 2G (FMUA) operation 6715.2 Flexi Mounting Kit Vertical for 2G (FMUA) construction 6915.3 Technical properties of Flexi Mounting Kit Vertical for 2G (FMUA) 7116 Flexi Mounting Kit Horizontal for 2G (FMUB) description 7316.1 Flexi Mounting Kit Horizontal for 2G (FMUB) operation and
construction 7316.2 Technical properties of Flexi Mounting Kit Horizontal for 2G (FMUB) 7417 I-HSPA Adapter description 7717.1 Overview of I-HSPA Adapter hardware 7717.2 Physical dimensions of the I-HSPA Adapter 7917.3 Physical interfaces of the I-HSPA Adapter 79
18 Talk Conversion Kit (EMIA or EMIB) 81
4 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
Summary of changes
Changes between document issues are cumulative. Therefore, the latestdocument issue contains all changes made to previous issues.
Changes between issues 8-1 and 8-2
Section Flexi Pole Mounting Kit (FPKA) description updated.
Section Flexi System External OVP (FSEC) description updated.Changes between issues 8-0 and 8-1
Section Flexi Mounting Kit for Floor, Wall and Pole (FMFA) descriptionedited.
Section Flexi Mounting Auxiliary Bracket (FMAA) description added.
Section Flexi Pole Mounting Kit (FPIA) description edited.
Section Flexi Pole Mounting Kit (FPKA) description edited.
Section Flexi System External OVP (FSEC) description edited.
Information related to Flexi system external GPS mediator (FSEG) hasbeen removed. Sections Flexi System External GPS Mediator (FSEG)operation, Flexi System External GPS Mediator (FSEG) dimensions andweight, Flexi System External GPS Mediator (FSEG) interfaces and GPSantenna removed.
Term Flexi Rectifier Module replaced with Flexi Power Rectifier andinformation related to it updated in sections FCIA cabinet construction,FCIA optional items, and FCOA optional items.
Editorial changes made.
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 5 (83)
Summary of changes
-
Changes between issues 7-1 and 8-0
Table Dimensions and weight of the FMFA in section Flexi mounting kit forfloor, wall and pole (FMFA) description edited.
Figure Flexi Pole Installation Kit (FPIA) added to section Flexi PoleInstallation Kit (FPIA) description.
Section Flexi Pole Mounting Kit (FPKA) description edited.
Section Flexi Mounting Covers for Back and Front (FMCA and FMCB)description edited.
Section Flexi Power Module (FPMA) and sub-modules (FPAA and FPBA)operation edited.
Section Flexi power DC/DC sub-module (FPDA) operation edited.
Section FCIA cabinet construction edited.
Section FCIA cabinet optional items edited.
Section FCOA optional items edited.
Section FCOA dimensions and weight edited.
Section Physical dimensions of the I-HSPA Adapter edited.
Section Physical interfaces of the I-HSPA Adapter edited.
Section Talk Conversion Kit (EMIA) edited and figure Parts needed forinstalling Flexi EDGE BTS modules in Citytalk cabinet added.
6 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
1 Flexi Mounting Kit for Floor, Wall andPole (FMFA) description
Flexi BTS modules are installed on the floor, wall or pole using FlexiMounting kit for Floor, Wall and Pole (FMFA). The FMFA consists of aplinth and adapter mechanics. The plinth is required in BTS siteinstallations without a cabinet and it provides grounding points for BTS andmodule grounding. The mounting principles are the following:
. In floor mounting, the plinth is fixed directly onto the floor. To meetthe Telcordia GR-63-CORE Vibrational requirements for earthquakeZone 4 requirement, the maximum number of modules in a stack isfive (maximum total height 15 U). To meet the Telcordia GR-63-CORE Vibrational requirements for earthquake Zone 2 requirement,the maximum number of modules in a stack is nine (maximum totalheight 22 U).
. In wall mounting, the plinth is fixed onto the wall either by usingadapter mechanics or directly to the wall. The maximum number ofmodules per plinth is two.
. In pole mounting, the plinth is fixed onto a pole mounting kit (VMPBor FPKA) by using adapter mechanics. Adapters are needed toreduce the influence of non-parallel surfaces of the mountingbrackets. The maximum number of modules per plinth is two.
The FMFA delivery includes two fixing plates for the casings. Used inpole and wall installations, the plates are attached across twomodule casings on both sides of the modules.
See the following figure for an isometric view of the FMFA.
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 7 (83)
Flexi Mounting Kit for Floor, Wall and Pole (FMFA) description
-
Figure 1. Isometric view of the plinth
See the following figure for the adapter mechanics.
Figure 2. Adapter mechanics
DN7082497
DN7099438
8 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
The plinth has a back stop that prevents installing the BTS too near to awall (40 mm).
The compartment behind the front panel of the plinth is used as a storageplace, for example, for seal caps.
FMFA dimensions and weight
The dimensions and weight of the FMFA are presented in the followingtable.
Table 1. Dimensions and weight of the FMFA
Property Value
Height 69 mm(2.7 in.)
Width 455 mm
(17.9 in.)Depth 459 mm
(18.1 in.)Weight Wall configuration 4.2 kg (9.3 lbs)
Floor configuration 2.9 kg (6.4 lbs)
The material of the plinth is 1.5 mm (0.06 in.) sheet metal.
For installation instructions, see Installing Flexi WCDMA BTS Modules forStack, Wall, and Pole Configurations.
External connections
The plinth has the following fixing interfaces:
. ESD studs (2 pcs)
. Casing fixing points (4 pcs)
. Pole/wall adapter fixing points (6 pcs)
. Threads for the lifting eye bolts (4 pcs)
. Modules grounding (24 pcs)
. BTS grounding (1 pcs)
. Casing locking points (2 pcs)
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 9 (83)
Flexi Mounting Kit for Floor, Wall and Pole (FMFA) description
-
. Anchoring points to floor (4 main and 2 optional)
. Fixing plate fixing points (4 pcs)
See the following figure for the external fixing interfaces of the FMFA.
Figure 3. External interfaces of the plinth
Anchoring pointsto floor
Modules groundingBTS grounding
ESD Stud
Threads for thelifting eye bolts
Casing fixing points
Fixing holes forfixing plates
Casing lockingpoints
Casing lockingpoints
Fixing holes foradapter plates
DN7082504
10 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
2 Pole Mounting Kit (VMPB) descriptionThe Pole Mounting Kit (VMPB) enables BTS installation on a pole 60-300mm (2.4-11.8 in.) in diameter.
See the following figure for an isometric view of the VMPB.
Figure 4. Pole Mounting Kit
See the following table for the delivery contents of the VMPB.
Table 2. Delivery contents
Item Quantity
Pole Mounting Kit (VMPB) 1Mounting blocks 2 pcs
M8x25 bolts 8 pcs
M10x120 bolts 4 pcs
M10x200 bolts 4 pcs
M10x300 bolts 4 pcs
Washers 4 pcs
DN70415461
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 11 (83)
Pole Mounting Kit (VMPB) description
-
See the following table for dimensions and weight of the VMPB.
Table 3. VMPB dimensions and weight
Property Value
Height 60 mm (2.4 in.)Width 350 mm (13.7 in.)Depth 300 mm (11.8)Weight 8.3 kg (18.3 lbs)
For installation instructions, see section Mounting the plinth on a pole inthe Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations document.
12 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
3 Flexi Mounting Auxiliary Bracket (FMAA)description
The Flexi Mounting Auxiliary Bracket (FMAA) can be used to mountauxiliary boxes (FSEB, FSEC) in pole, wall, stack, or EMIA/EMIBinstallations. One FSEB can be installed to the Citytalk Cabinet without theuse of FMAA.
The FMAA is mounted to the top casing in horizontal stacks and the outercasing in vertical installations. The auxiliary boxes are then mounted to theFMAA based on their own installation principles. There is enough spacefor a maximum of one FSEC box and one FSEB box or two FSEC boxes.
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 13 (83)
Flexi Mounting Auxiliary Bracket (FMAA) description
-
Figure 5. Flexi Mounting Auxiliary Bracket (FMAA)
DN70449903
14 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
4 Flexi Pole Installation Kit (FPIA)description
Flexi Pole Installation Kit (FPIA) consists of an installation plate, strainingstrap and four screws. It is used for installing the following auxiliary units toa pole:
. Flexi System External Alarm (FSEB)
. Flexi System External OVP (FSEC)
The pole can between 60 mm (2.4 in.) and 120 mm (4.7 in.) in diameter.
There are two sets of fixing points on the installation plate. The FPIA cancarry the weight of 5 kg (11 lbs).
For the FPIA delivery contents, see section Contents of the Flexi PoleInstallation Kit (FPIA) delivery in the Installing Flexi WCDMA BTS OptionalItems document.
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 15 (83)
Flexi Pole Installation Kit (FPIA) description
-
Figure 6. Flexi Pole Installation Kit (FPIA)
DN70458657
16 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
5 Flexi Pole Mounting Kit (FPKA)description
The Flexi Pole Mounting Kit (FPKA) can be used with poles between 60mm (2.4 in.) and 120 mm (4.7 in.) in diameter. The most commonly usedsize is 80 mm (3.1 in.). The FPKA can replace the VMPB Pole Mounting kitin installations where the pole diameter is less than 120 mm (4.7 in.).
See the following figure for the FPKA
Figure 7. Flexi Pole Mounting Kit (FPKA)
The width of the fixing points is 184 mm (7.2 in.) and 64 mm (2.5in.). Thereare fixing points in three sides of the FPKA. The M10 screws should betightened to 30 Nm and the M8 screws to 20 Nm. The FPKA can carry themaximum weight of 160 kg (352.7 lbs).
The delivery contents of the FPKA are listed in the following table.
Bolt M8x20
Bolt M10X120105 mm thread
Fixingpoints184mm (7.2 in.)
Fixingpoints64mm (2.5 in.)
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 17 (83)
Flexi Pole Mounting Kit (FPKA) description
-
Table 4. FPKA delivery contents
Item Quantity
FPKA Bracket 1 pcs.
Bolt M8 x 20 6 pcs.
Bolt restrainer 2 pcs.
FPKA bracket strainer 1 pcs.
Bolt M10 x120 105 mm thread
ISO 4762 (DIN912)2 pcs.
Installation with Remote Radio Heads
The FPKA has room for three Remote Radio Heads (FRGG). It is possibleto use three installation directions. See the following figure for the FPKAinstallation with three Remote Radio Heads.
18 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
Figure 8. FPKA with three Remote Radio Heads
Installation with Flexi modules
The FPKA has room for a maximum of four 3U Flexi modules (12U total).Two modules (or casings) can be installed on opposite sides of the FPKA.See the following figure for the FPKA Installation with four 3U modules.
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 19 (83)
Flexi Pole Mounting Kit (FPKA) description
-
Figure 9. FPKA with four 3U Flexi Modules
Installation with MetroSite 50
The FPKA supports the MetroSite 50 with two installation directions. Seethe following figure for the FPKA installation with MetroSite 50.
DN70424752
20 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
Figure 10. FPKA with MetroSite 50
DN70424776
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 21 (83)
Flexi Pole Mounting Kit (FPKA) description
-
22 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
6 Flexi Mounting Covers for Back andFront (FMCA and FMCB) description
Flexi mounting covers for back and front are optional 3U (FMCA) and 2U(FMCB) module covers that are required in installations without a cabinet.The primary functions of the covers are to provide protection against wind-driven rain, visual protection, and mechanical protection for the cables.Furthermore, the back cover protects the installer's fingers from therotating fans. The front cover air deflector is semi-transparent to allowassessing the status of the hardware LEDs without removing the frontcovers.
For installation instructions, see section Installing back and front covers inthe Installing Flexi WCDMA BTS Optional Items document.
The FMCA and FMCB deliveries include a grounding cable. Note that it isnot included in any module deliveries.
The back and front covers, the safety catches and the grounding cable areillustrated in the following figure.
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 23 (83)
Flexi Mounting Covers for Back and Front (FMCA and FMCB)description
-
Figure 11. FMCA: 3U back cover, 3U front cover, 2 x safety catch andgrounding cable
FMCA dimensions
The dimensions of the FMCA are presented in the following table.
Table 5. Dimensions of the FMCA
Property Front cover Back cover
Height 128 mm(5 in.)
128 mm
(5 in.)Width 492 mm
(19.4 in.)446 mm
(17.6 in.)Depth 100 mm
(3.9 in.)37 mm
(1.5 in.)
DN7082516
Front cover Back cover
2 x safety catch Grounding cable
24 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
Table 6. Dimensions of the FMCB
Property Front cover Back cover
Height 83 mm(3.3 in.)
83 mm
(3.3 in.)Width 492 mm
(19.4 in.)446 mm
(17.6 in.)Depth 100 mm
(3.9 in.)37 mm
(1.5 in.)
The material of the covers is plastic.
Table 7. Grounding cable
Property Value
Length 1.3 m (4.3 ft.)Thickness 16 mm2 (5 AWG)
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 25 (83)
Flexi Mounting Covers for Back and Front (FMCA and FMCB)description
-
26 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
7 Flexi System External Alarm (FSEB)description
7.1 Flexi System External Alarm Box (FSEB) operation
The FSEB box is used for extending the Flexi BTS alarm connector tosupport up to 24 alarm interfaces. 12 alarms are supported for FlexiWCDMA BTS. Support for the fire detector is also provided. The FSEB boxprovides IP55 protection.
In outdoor applications, the box can be attached to the outdoor cabinetroof. There are fixing points for the FSEB in the outdoor cabinet. In indooror stacked applications, the box is attached in the proximity of themodules, for example, on a wall.
The Flexi Mounting Auxiliary Brackets (FMAA) can be used to mount theFSEB on the top or outer casings in pole, wall, and stack configurations.The brackets are mounted on the top or outer casing using the existingconnection pin holes. Flexi Pole Installation Kit (FPIA) can be utilised forpole installations.
For installation instructions, see section Installing Flexi System ExternalAlarm (FSEB) in the Installing Flexi WCDMA BTS Optional Itemsdocument.
7.2 Flexi System External Alarm (FSEB) dimensionsand weight
The dimensions and weight of the FSEB are presented in the followingtable.
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 27 (83)
Flexi System External Alarm (FSEB) description
-
Table 8. FSEB dimensions
Property Value
Width 335 mm
(13.2 in.)Height 94 mm
(3.7 in.)Depth 182 mm
(7.2 in.)Weight Max. 2 kg
(4.4 lbs)
The mounting dimensions of the FSEB enclosure are 110 mm x 324 mm(4.3 in. x 12.8 in.).
The material of the box is plastic.
7.3 Flexi System External Alarm (FSEB) interfaces
See the figure below for the FSEB mechanical interfaces:
28 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
Figure 12. FSEB interfaces
PWB interface
The PWB interface and connectors are presented in the table below.
Table 9. Interface and connector overview
Interface Type Description
EACX-I Sub-D37, female . 12 direct alarm inputs. 6 alarm outputs
(ESM extension,compatible to EAC onESM)
EACX-S 10 SMDK1/6-3.5 60 pin screw terminalcombines EACX-I, EACX-II
Fire detector powersupply
Screw terminal DC power supply for theoptional fire detector
ESM Sub-D37, male Interface to the SystemModule, *CAN bus
BTS interconnectioncable
UltraSite and Talkswap cases
EAC M16
Grounding point
DN70283679
ESD
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 29 (83)
Flexi System External Alarm (FSEB) description
-
Table 9. Interface and connector overview (cont.)
Interface Type Description
*EACX-II Sub-D37, female 12 alarm inputs via CANbus
*Not used in WCDMA mode.
See the following figure for the FSEB PWB.
Figure 13. FSEB PWB
DN70410509
ESM
EACX-II(D37)
EACX-I(D37)
grounding
Smoke-DetectorPower X4114
EACX-S screw terminalsX4104 to X4113
Not in use
30 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
8 Flexi System External OVP (FSEC)description
Flexi System External OVP (FSEC) protects Flexi WCDMA sub-modulesagainst surge pulse(s) in power feeding lines.
This section describes protection device only for DC lines in the feederlesssite solution. The FSEC gives Class II (C, T2) protection for DC power feedand provides IP55 protection. For FSEC installation instructions, seesection Installing Flexi System External OVP (FSEC) in the Installing FlexiWCDMA BTS Optional Items document.
The FSEC box is also used for altering the DC cable diameter. For moredetailed information on the FSEC usage in the feederless site solution, seeInstalling feederless or distributed site in the Cabling Flexi WCDMA BTSand Creating Configurations document.
The FSEC does not require regular maintenance.
Figure 14. Isometric view of the FSEC
DN70154491
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 31 (83)
Flexi System External OVP (FSEC) description
-
See the following figures for the internal and external wiring of the FSEC.
Figure 15. FSEC internal wiring (version 6Yxxxxxxxxx)
FSEC
+ + - -PE PE
VAL-MS60 ST
VAL-MS60 ST
PE terminals are electricallyconnected to DIN rail
Internal wiring (factory cabling) version 6Yxxxxxxxxx
GND
0V (+)
PE
-48 V
Electrical connection
DN70592401
32 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
Figure 16. FSEC external wiring (version 6Yxxxxxxxxx)
FSEC dimensions
The dimensions of the Flexi system external OVP box are presented in thefollowing table. The FSEC is made of aluminium.
FSEC
+ + - -PE PE
VAL-MS60 ST
VAL-MS60 ST
External wiring, version 6Yxxxxxxxxx
System/RF Module
Cableshield
To otherFSEC
Ground cable to plinthor site grounding barDC cable type:
MCCMK/MCMK(or equivalent)
DN70592413
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 33 (83)
Flexi System External OVP (FSEC) description
-
Table 10. FSEC dimensions
Property Value
Width 95 mm
(3.7 in.)Height 155 mm
(6.1 in.)Depth 155 mm
(6.1 in.)Weight 2.7 kg
(5.9 lbs)
FSEC connectors
In the FSEC, there are screw terminals for input and output cables. Thereare four pieces of screw terminals for AWG 2 cables and for earthing twoPEs (protective earthing GND) terminals for AWG 2 cable size. A 2-meterDC cable is included in the FSEC delivery.
34 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
9 Flexi Power Module (FPMA) and sub-modules (FPAA and FPBA) description
9.1 Flexi Power Module (FPMA) and sub-modules(FPAA and FPBA) operation
Flexi Power Module (FPMA) is an optional module. It comprises FPMAmechanics and AC and DC interfaces. The actual power sub-modules arethe following:
. Flexi Power AC/DC sub-module 200-240 V AC (FPAA)
. Flexi Power Battery sub-module (FPBA)
The maximum number of sub-modules in an FPMA is four.
For installation instructions, see section Installing Flexi Power Module(FPMA) in the Installing Flexi WCDMA BTS Optional Items document.
The FPMA is presented in the following figures.
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 35 (83)
Flexi Power Module (FPMA) and sub-modules (FPAA and FPBA)description
-
Figure 17. Power Module (FPMA)
Figure 18. FPMA: full configuration with two FPAAs and two FPBAs
DN70230045
Type label
DN7084386
36 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
The FPMA can support 1-phase and 3-phase AC input. The nominal inputvoltage is 200-240 V AC (the operating voltage range is 180 - 276 V AC).The maximum output power from the FPMA is 4kW (with 4 FPAAs).Flexi Power AC-DC sub-module (FPAA)
The main function of the FPAA is to provide the BTS with nominal 48 V DCpower from an AC supply. Maximum DC output power of one FPAAmodule is 1000 W. A nominal 48 V DC supply is intended for BTS internaluse only (a nominal 48 V DC supply is not intended for 3rd partyequipment because they may require lower conducted emission level thanEN55022 Class A). The FPAA includes its own integrated self-controlledfan. In case the fan fails, an alarm is generated and the FPAA has to bereplaced (the fan alone cannot be replaced).
Caution
Risk of thermal runaway of the battery, because temperaturecompensation of charging voltage is not supported. Do not connect anexternal lead acid battery for longer backup times to a nominal 48 V DCsupply.
Flexi Power Battery sub-module (FPBA)
The Flexi Power Battery Sub-Module (FPBA) is a separate optional sub-module used together with the FPAA.
The FPBA provides short-term battery backup time when the AC powermains is down on a Flexi BTS site. The FPBA is a lithium ion battery. Themaximum DC output power from one FPBA module is 1000 W. The inputpower for the BTS cannot exceed the maximum output power of theinstalled batteries. Otherwise the batteries do not provide the BTS with theneeded power during power failure.
9.2 Flexi Power Module (FPMA) dimensions and weight
The following table lists the dimensions and weight for Flexi Power Module(FPMA).
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 37 (83)
Flexi Power Module (FPMA) and sub-modules (FPAA and FPBA)description
-
Table 11. Dimensions and weight of the FPMA
Property FPMA
Height 133 mm/3 U(5.2 in.)
Width 447 mm
(17.6 in.)Depth without covers 422 mm
(16.6 in.)Depth with covers 560 mm
(22.1 in.)Weight (empty) < 11 kg
(< 24.3 lbs)Weight(fully equipped with one AC/DCpower module and batteries)
28 kg(61.9 lbs)
9.3 Flexi Power Module (FPMA) and sub-module (FPAAand FPBA) interfaces
FPMA front panel connectors
The connectors on the FPMA front panel, their types and purposes arelisted in the table below.
Table 12. FPMA front panel connectors, types and purposes
Connector Type Purpose
Power supply in Terminal block AC main power supply in
Power supply out 2-wire DC cable 4 x multi-beam
DC feed to the BTS
Grounding 2 x M5 Module grounding
38 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
FPAA front panel connectors
There is a stand-by switch on the front panel of the FPAA. The stand-byswitch is used for switching the FPAA unit ON/stand-by.
The connectors on the FPAA front panel, their types and purposes arelisted in the table below.
Table 13. FPAA front panel connectors, types and purposes
Connector Type Purpose
AC cable connector Mate-N-Lock AC input
DC connector Multi-beam power supplyconnector
DC output
Alarm connector 2 x RJ-45* Alarms**
Operational state visualindication
tri-colour LED FPAA state or alarmindication
*for chaining
**Alarm 1 (AL01): AC input failure (alarm is sent when AC input voltage ismissing or it is out of range).
**Alarm 2 (AL02): maintenance needed (possible reasons are unit failure,cooling fan failure, output power is low or over temperature shut down isON).FPBA front panel connectors
There is a stand-by switch on the front panel of the FPBA.
The connectors on the FPBA front panel, their types and purposes arelisted in the table below.
Table 14. FPBA front panel connectors, types and purposes
Connector Type Purpose
DC input/output connector Multi-beam power supplyconnector
DC input and output
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 39 (83)
Flexi Power Module (FPMA) and sub-modules (FPAA and FPBA)description
-
Table 14. FPBA front panel connectors, types and purposes (cont.)
Connector Type Purpose
Alarm connector 2 x RJ-45* Alarms**
Operational state visualindication
tri-colour LED FPBA state or alarmindication
*for chaining
**Alarm 2 (AL02): maintenance needed (possible reasons are unit failure,output power is low or unit has reached end of it's life).
**Unit has an input for Alarm 1 (AL01) from FPAA unit (Alarm 1 is a triggerfor battery discharging).
9.4 Flexi power sub-module (FPAA and FPBA) LEDindications
FPAA LED indications
The FPAA LED indications are explained in the table below. Read theinformation on LED indications thoroughly. A blinking red LED does notalways require removing the module.
Table 15. FPAA LED indications
Colour Explanation
Yellow Stand-by (AC connected)Green Normal operation
Red Alarm or fault
Red, blinking Unit operating with abnormal input voltage
See the following figure for the location of the FPAA LED.
40 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
Figure 19. FPAA LED
FPBA LED indications
The FPBA LED indications are explained in the table below.
Table 16. FPBA LED indications
Colour Explanation
Yellow Stand-by (DC connected from FPAA)Ggreen Normal operation, battery OK
Green, blinking slowly Charging
Green, blinking fast Discharging
Blinking fast between green and yellow Forced discharge mode
Red, blinking fast Minor alarm
Red Major alarm or fault
The LED's slow blinking frequency is 1 Hz (1 sec) and fast blinkingfrequency 2 Hz (0.5 sec).
See the following figure for the location of the FPBA LED.
DN70350654
LED
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 41 (83)
Flexi Power Module (FPMA) and sub-modules (FPAA and FPBA)description
-
Figure 20. FPBA LED
DN70350678
LED
42 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
10 Flexi Power DC/DC Module (FPDA)description
10.1 Flexi Power DC/DC Module (FPDA) operation
Flexi Power DC/DC Module (FPDA) is an optional stand-alone 2 kW DC/DC module.
When the BTS power load is more than 2 kW, multiple FPDAs can beinstalled in parallel. When FPDAs are used in parallel, a maximum of twoDC cables can be installed together at each output terminal.
Conducted emission level of the 53-55 V DC supply is according to thestandard EN55022 Class A. The 53-55 V DC supply is intended for BTSinternal use only (the 53-55 V DC supply is not intended for 3rd partyequipment because they may require lower conducted emission level thanEN55022 Class A).
Caution
Risk of thermal runaway of the battery, because temperaturecompensation of charging voltage is not supported. Do not connect anexternal lead acid battery for longer backup times to the 53-55 V DCsupply.
The FPDA includes its own integrated self-controlled fan. In case the fanfails, an alarm is generated and the fan has to be replaced.
For installation instructions, see section Installing Flexi Power DC/DCModule 24V FPDA in the Installing Flexi WCDMA BTS Optional Itemsdocument.
The FPDA is presented in the following figure.
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 43 (83)
Flexi Power DC/DC Module (FPDA) description
-
Figure 21. Flexi Power DC/DC Module (FPDA)
10.2 Flexi Power DC/DC Module (FPDA) dimensions andweight
The following table lists the dimensions and weight for the FPDA.
Table 17. Dimensions and weight of the FPDA
Property Value
Height 90 mm (2U)(3.5 in.)
Width 447 mm
(17.6 in.)Depth without covers 422 mm
(16.6 in.)Depth with covers 560 mm
(22.1 in.)
DN70150502
44 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
Table 17. Dimensions and weight of the FPDA (cont.)
Property Value
Weight < 15 kg(< 33.1 lbs)
10.3 Flexi Power DC/DC Module (FPDA) interfaces
There is a stand-by switch on the front panel of the FPDA.
The connectors on the FPDA front panel, their types and purposes arelisted in the table below.
Table 18. FPDA front panel connectors, connector types and purposes
Connector Connector type Purpose
Input connector M10 bolts DC input
Output connector M10 bolts DC output
Alarm connectors 2 x RJ-45* Alarms**
*for chaining
**Alarm 1 (AL01): DC input failure (alarm is sent when DC input voltage ismissing or it is out of range).
**Alarm 2 (AL02): maintenance needed (possible reasons are unit failure,cooling fan failure, output power is low or over temperature shut down isON).
The FPDA front panel is presented in the following figure.
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 45 (83)
Flexi Power DC/DC Module (FPDA) description
-
Figure 22. Front panel of the FPDA
10.4 Flexi Power DC/DC Module (FPDA) LED indications
The FPDA has a tri-colour LED on the front panel to indicate theoperational status of the module and all fault conditions during operation.Read the information on LED indications thoroughly. A blinking red LEDdoes not always require removing the module. The LED indications of theFPDA are listed and explained in the table below.
Table 19. FPDA LED indications
Colour Explanation
Green Normal operation
Red Alarm or fault
Yellow Stand-by
Red, blinking Abnormal input voltage
DN70141402
DC Input cabling DC Output cablingAlarm cabling
GND
LED
46 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
11 Flexi Power AC/DC sub-module (FPAB)description
Flexi Power AC/DC sub-module 100/240V (FPAB) is a front-end rectifierassembly that converts AC input voltage to DC output voltage. The mainapplication for the FPAB is to operate as an AC/DC converter for the singleRF Module of the Flexi WCDMA BTS. In this application, the FPAB isinstalled on top of the 3U Single RF Module core, in the free slot of theunused filter.
For installation instructions, see sections Installing the FPAB (Astec) to asingle RF Module and Installing the FPAB (Efore) to a single RF Module inthe Installing Flexi WCDMA BTS Optional Items document.
See the following figure for an isometric view of the FPAB.
Figure 23. Isometric view of the FPAB
DN70265249
LED
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 47 (83)
Flexi Power AC/DC sub-module (FPAB) description
-
See the following table for FPAB input/output voltage.
Table 20. FPAB input/output voltage
Property Value
Nominal input voltage 100 - 240 V AC (single phase)Input voltage range 90 - 276 V AC
Output voltage 56 V DC at 500 W
See the following figure for the FPAB connectors.
Figure 24. FPAB connectors
See the following figure for installing the FPAB in the RF Module.
DN70407333
DC output(multi-beam connector)
AC input(row connector)
A
B
48 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
Figure 25. Installing the FPAB in the Single RF Module
FPAB dimensions
The dimensions of the FPAB are presented in the following table.
Table 21. FPAB dimensions
Property Value
Width 124 mm (4.9 in.)Height 73 mm (2.9 in.)Depth 345 mm (13.6 in.)Weight Max. 2.6 kg (5.7 lbs)
DN70286831
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 49 (83)
Flexi Power AC/DC sub-module (FPAB) description
-
The FPAB LED indications are explained in the following table.
Table 22. FPAB LED indications
Colour Explanation
Yellow Stand-by (AC connected)Green Normal operation
50 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
12 Flexi Cabinet for Indoor (FCIA)description
12.1 FCIA cabinet construction
Flexi BTS Indoor cabinet (FCIA) has a cabinet core made of an aluminiumchassis enclosed with aluminium doors and sides. The FCIA cabinet doesnot carry any electrical functionality; there are no traditional backplanes orelectronics. The cable entries are located at the top of the cabinet. Externalcables are connected directly to the Flexi modules inside the cabinet.
The following optional modules can be mounted to the FCIA cabinet:
. Integrated long term battery backup solution (MIBBU)
. Flexi Power Rectifier (FPRx)
. EAC connection box (FSEB)
. Overvoltage protection box (FSEC)
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 51 (83)
Flexi Cabinet for Indoor (FCIA) description
-
Figure 26. FCIA cabinet
12.2 FCIA optional items
Flexi BTS Indoor Cabinet (FCIA) can include the following optional items:Flexi System External Alarm Module (FSEB)
Flexi System External Alarm box (FSEB) is installed on the cabinet roofand contains 12 external alarms and 6 controls.
DN70253985
52 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
Flexi System External OVP (FSEC)
Flexi System External OVP (FSEC) is installed on the cabinet roof.Multi Integrated Battery Backup Solution (MIBBU)
The optional Multi Integrated Battery Backup solution (MIBBU) with aseparate battery can be installed in Nokia Flexi BTS Indoor Cabinet.
The Multi Integrated Battery Backup Solution consists of
. one power distribution unit (WPU) with one control unit (CU), and
. one to four rectifier power units (WPM).
The power distribution unit mainly distributes the input AC mains to therectifier units. The control unit controls the rectifier power units andmonitors the alarms in the event of low supply voltage, or if the MIBBUenters the battery backup mode in the event of an AC mains failure. Thealarm generated by the control unit is forwarded to the BTS O&M software.
Flexi Power Rectifier (FPRx)
The Flexi Rectifier Module (FPRA) is a modular 6kW output power ACrectifier package made up of three individual 2kW AC/DC power modulesoperating in a parallel mode configuration. The FPRA outputs a positiveearthed 54VDC (V48N) as a respective BTS operational supply voltagerail and for site battery charging. It supports 2G and 3G Flexi BTSconfigurations (indoor and outdoor cabinets, and stack, pole and wallconfigurations).Flexi Battery Mounting Kit for FCIA (FMBB)
Flexi Battery Mounting Kit (FMBB) is needed when using batteries or theMIBBU solution in FCIA. The mounting kit is installed at the bottom of thecabinet.
12.3 FCIA dimensions and weight
See the following table for the dimensions and weight of the Flexi Cabinetfor Indoor (FCIA).
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 53 (83)
Flexi Cabinet for Indoor (FCIA) description
-
Table 23. Dimensions and weight of Flexi Cabinet for Indoor (FCIA).
Property Value
Height 1800 mm / 40.5U(70.87 in.)
Width 600 mm
(23.62 in.)Depth 600 mm
(23.62 in.)Weight(empty cabinet)
62 kg(136 lbs.)
Free space for modules 36 U
54 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
13 Flexi Cabinet for Outdoor (FCOA)description
13.1 Flexi Cabinet for Outdoor (FCOA) construction
Flexi Cabinet for Outdoor (FCOA) has a cabinet core made of analuminium chassis enclosed with aluminium covers. The cabinet door canbe locked with a triangle door-open key. The cabinet can also be fitted withan optional security lock for additional protection. The FCOA itself does nothave any electrical functionality and therefore, it does not increase FlexiBTS site power consumption
The cabinet has the following functions:
. it provides the base station and cables protection against externaldamage and foreign objects
. it supports earthquake protection
. it houses the Flexi cabinet site support module (FCSA) that provideslong-term battery back-up and a 4U-high IP55-protected space forLine Terminal Equipment (LTE)
. together with Flexi cabinet air filter (FCFA), it protects the BTS inextremely dirty conditions
The FCOA provides earthquake protection for an installation of more thannine modules.
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 55 (83)
Flexi Cabinet for Outdoor (FCOA) description
-
Figure 27. FCOA cabinet
13.2 FCOA optional items
This section describes the optional items of Flexi BTS Outdoor cabinet(FCOA).Flexi Cabinet Air Filter (FCFA)
The optional air filter (FCFA) can be added in case of extremely dirtyenvironment (for fresh air cooled modules). The optional air filter providescover for extremely dirty conditions by over-pressurizing the cabinet. TheFCFA delivery includes the air filter and a wind plate.
DN70138414
56 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
The air filter is installed in the back of the cabinet, replacing the originalback wall. It consists of a filter element, 8 x diagonal fans, a pressuresensor, a control logic, and back wall mechanics. The wind plate isinstalled in the cabinet door.
The control of the FCFA fans is based on a pressure sensor. The pressuresensor measures pressure inside the cabinet and this information is thenused for controlling the fan speed.
The air filter is presented in the following figure.
Figure 28. Air filter
DN70150526
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 57 (83)
Flexi Cabinet for Outdoor (FCOA) description
-
Flexi Cabinet Site Support Module (FCSA)
The optional site support module (FCSA) can be used with the outdoorcabinet to provide long-term battery back-up time for the Flexi WCDMABTS and a space for installing Line Terminal Equipment (LTE) units. TheFCSA provides IP55 protected installation space for the PDU unit, IBBUAC interface box, rectifier units, LTE equipment, control card, heatexchanger, and fans.
There is a separate option for battery installation in the site supportmodule. Batteries are fixed and cabled using Flexi Mounting Kit forBatteries (FMBA). The kit contains battery cables, a cable from IBBU to thebattery cables for safe installation, rubber spacers, and front fixing parts tothe batteries.
The site support is presented in the following figure.
58 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
Figure 29. Site support
Flexi Power Rectifier (FPRx)
The Flexi Rectifier Module (FPRA) is a modular 6kW output power ACrectifier package made up of three individual 2kW AC/DC power modulesoperating in a parallel mode configuration. The FPRA outputs a positiveearthed 54VDC (V48N) as a respective BTS operational supply voltagerail and for site battery charging. It supports 2G and 3G Flexi BTSconfigurations (indoor and outdoor cabinets, and stack, pole and wallconfigurations).
DN70150538
LTE Space
Controlcard
Batteries
FMBA
HeatExchanger
MIBBU
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 59 (83)
Flexi Cabinet for Outdoor (FCOA) description
-
Flexi Cabinet Fire Detector (FCDA)
The fire detector is installed on the cabinet roof, and the cables are routedto the Flexi System External Alarm (FSEB).
The following figure presents the fire detector.
Figure 30. Fire detector
Flexi System External OVP (FSEC)
Flexi System External OVP (FSEC) is an IP-protected box for overvoltageprotection and power terminals. The FSEC is installed on the cabinet roof.For more information on the FSEC, see Flexi System External OVP(FSEC) description.
13.3 Flexi Cabinet for Outdoor (FCOA) dimensions andweight
See the following table for the dimensions and weight of the Flexi Cabinetfor Outdoor (FCOA).
DN70150541
60 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
Table 24. Dimensions and weight of the Flexi Cabinet for Outdoor (FCOA)
Property Value
Height 1550 mm(61 in.)
Width 770 mm
(30.3 in.)Depth 770 mm
(30.3 in.)Depth with air filter 930 mm
(36.6 in.)Depth with air filter and wind plate 1020 mm
(40.2 in.)Weight(empty cabinet)
Max. 80 kg(177 lbs)
Weight(with air filter)
104 kg(230 lbs)
Weight(with air filter and wind plate)
110 kg(243 lbs)
Total weight(Fully equipped with batteries)
365 kg(807 lbs)
Free space for modules 40 U(30 U horizontally + 5 U + 5 U vertically
Free space for modules(site support and batteries installed)
21 U
(16 U horizontally + 5 U vertically)
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 61 (83)
Flexi Cabinet for Outdoor (FCOA) description
-
62 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
14 Flexi Mounting Shield (FMSA and FMSB)description
14.1 Flexi Mounting Shield (FMSA and FMSB) operationand construction
Flexi Mounting Shield (FMSA/FMSB) is an outdoor cabinet for a stackedFlexi BTS. Used instead of the plastic front and rear covers, it providesprotection against solar load, large insects and slight vandalism. FlexiMounting Kit Floor/Wall/Pole (FMFA) is required in both cabinets.
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 63 (83)
Flexi Mounting Shield (FMSA and FMSB) description
-
Figure 31. Isometric view of the FMSA
DN70324735
64 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
Figure 32. Isometric view of the FMSB
The FMSA provides installation space for up to any two Flexi 3U modulesand the plinth (6U in total). It is installed on a pole or wall.
The FMSB provides space for up to any six Flexi 3U modules and theplinth (18U in total). It is installed on the floor.
DN70324723
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 65 (83)
Flexi Mounting Shield (FMSA and FMSB) description
-
Flexi 3U Mounting Covers front/back (FMCA) as well as RF Module andSystem Module cable entries are not used in mounting shield installations.The cabinet door is right-handed (the handedness cannot be changed).
For installation instructions, see sections Installing Flexi Mounting Shield6U (FMSA) and Installing Flexi Mounting Shield 18U (FMSB) in theInstalling Flexi WCDMA BTS Modules in Cabinets document.
14.2 Flexi Mounting Shield (FMSA and FMSB)dimensions and weights
See the following table for the dimensions and weight of the FlexiMounting Shields (FMSA/FMSB).
Table 25. Dimensions and weight of Flexi Mounting Shield 6U (FMSA)
Property Value
Height 605 mm (23.8 in.)Width 400 mm (15.7 in.)Depth 620 mm (24.4 in.)Weight (empty) 12 kg (26.5 lbs.)Free space for modules 6U
Table 26. Dimensions and weight of Flexi Mounting Shield 18U (FMSB)
Property Value
Height 930 mm (36.6 in.)Width 605 mm (23.8 in.)Depth 620 mm (24.4 in.)Weight (empty) 21 kg (46.3 lbs.)Free space for modules 18U
66 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
15 Flexi Mounting Kit Vertical for 2G (FMUA)description
15.1 Flexi Mounting Kit Vertical for 2G (FMUA) operation
With Flexi Mounting Kit Vertical for 2G, Flexi WCDMA modules can beinstalled on existing GSM/EDGE UltraSite sites. The mounting kit can beused with the following indoor and outdoor GSM/EDGE UltraSite cabinets:
. UltraSite EDGE BTS (CRMA)
. UltraSite Indoor Cabinet (IDCA) v. 101
. UltraSite Outdoor Cabinet (ODCA) v. 101
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 67 (83)
Flexi Mounting Kit Vertical for 2G (FMUA) description
-
Figure 33. FMUA with WCDMA BTS installed
Tip
The example RF Modules shown in the figure are Dual RF Modules.
Before the mounting kit can be installed, the following parts are removedfrom the lower half of the GSM/EDGE UltraSite cabinet:
. 3 x fans
. RFU back plane
. WBC fan box
2G
SystemModule
RF Module
DN7082146
1 U free space
68 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
The mounting kit consists of one dual rack in which one System Moduleand one RF Module are installed, one single rack for the second RFModule installation, and cables. There is a remaining space of 1 U in thesingle rack when the RF Module is installed.
For installation instructions, see section Overview of installing modules incabinet with Flexi Mounting Kit Vertical for 2G in the Installing FlexiWCDMA BTS Modules in Cabinets document.
15.2 Flexi Mounting Kit Vertical for 2G (FMUA)construction
The mounting kit dual rack and single racks are made of aluminium andinclude mounting for fans and air ducts. See the following figure for anillustration of the racks.
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 69 (83)
Flexi Mounting Kit Vertical for 2G (FMUA) description
-
Figure 34. FMUA parts (dual and single racks)
FRONT BACK
FRONT BACK
Dual rack
Single rack
DN7082037
70 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
15.3 Technical properties of Flexi Mounting Kit Verticalfor 2G (FMUA)
The following table illustrates the dimensions and weights of the two racksof the mounting kit.
Property Dual rack Single rack
Height 694 mm(27.3 in.)
585 mm
(23 in.)Width 302 mm
(11.9 in.)196 mm
(7.7 in.)Depth 395 mm
(15.6 in.)400 mm
(15.8 in.)Weight 6.2 kg
(13.7 lbs)4.6 kg(10.2 lbs)
The loss of RF cables 0.7dB 0.7dB
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 71 (83)
Flexi Mounting Kit Vertical for 2G (FMUA) description
-
72 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
16 Flexi Mounting Kit Horizontal for 2G(FMUB) description
16.1 Flexi Mounting Kit Horizontal for 2G (FMUB)operation and construction
With Flexi Mounting Kit Horizontal for 2G, Flexi WCDMA modules can beinstalled on existing GSM/EDGE UltraSite sites. The mounting kit can beused with the following indoor and outdoor GSM/EDGE UltraSite cabinets:
. UltraSite Indoor Cabinet (IDCA) v. 202 or newer
. UltraSite Outdoor Cabinet (ODCA) v. 202 or newer
. UltraSite EDGE Outdoor Cabinet (ODCF)
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 73 (83)
Flexi Mounting Kit Horizontal for 2G (FMUB) description
-
Figure 35. Isometric view of Flexi Mounting Kit Horizontal for 2G
The mounting kit consists of a rack in which, for example, one WCDMASystem Module, up to three WCDMA RF Modules and one FPMA orSystem Extension Module or FPDA are installed, and cables. The spacerequirement for 5 x 3U modules is 15U.
For installation instructions, see section Installing modules in cabinet withFlexi Mounting Kit Horizontal for 2G in the Installing Flexi WCDMA BTSModules in Cabinets document.
16.2 Technical properties of Flexi Mounting KitHorizontal for 2G (FMUB)
The following table illustrates the dimensions and weight of the FMUB.
DN70231874
74 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
Property FMUB
Height 732 mm (28.8 in.)Width 525 mm (20.7 in.)Depth 393 mm (15.5 in.)Weight of the side wall 1.73kg (3.8 lbs)Weight(cables excluded)
Max. 20 kg (44 lbs)
The loss of RF cables 0.7dB
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 75 (83)
Flexi Mounting Kit Horizontal for 2G (FMUB) description
-
76 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
17 I-HSPA Adapter description17.1 Overview of I-HSPA Adapter hardware
The I-HSPA Adapter has been designed as a 1U high 19-inch rackelement to be installed in any BTS cabinet or enclosure where the FlexiBTS can be installed, such as the Flexi BTS indoor and outdoor cabinets,the UltraSite GSM/EDGE cabinet, with either horizontal or vertical fixingkit; and standard 19-inch equipment racks.
Figure 36. Nokia Siemens Networks I-HSPA Adapter
The I-HSPA Adapter can be fitted to a Flexi BTS 2U module casing. Whenused with the Flexi BTS module casing, the I-HSPA Adapter can beinstalled with the Flexi WCDMA BTS in stand-alone configurations, suchas free-standing, wall mounted or pole mounted.
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 77 (83)
I-HSPA Adapter description
-
Figure 37. I-HSPA Adapter and Flexi BTS module casing
The I-HSPA Adapter uses forced air cooling based on fresh air intake fromback to front. This allows it be installed either horizontally or vertically. Thecontents of the I-HSPA Adapter delivery also include an air-blocking plate,to be used if the I-HSPA Adapter is with the Flexi BTS 2U module casing.
The I-HSPA Adapter features a lightweight aluminium alloy casing withstainless steel alloy used for the fan carrier.
Figure 38. Views of I-HSPA Adapter
Rear Cover
Casing
I-HSPA Core mechanics
Front Cover
DN70287651
78 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
17.2 Physical dimensions of the I-HSPA Adapter
The I-HSPA Adapter is mechanically compatible with Flexi BTS 2U modulecasing.
Table 27. Dimensions of I-HSPA Adapter, including fan module
Width without the fastening ears 441 mm (not including fixing points)Height 43 mm
Depth from front plate 299 mm
Weight, including core mechanics, PWBand PMS
4.7 kg
Table 28. Dimensions of I-HSPA Adapter with Flexi BTS 2U casing
Width 465 mm (between fixing points)Height 84.05 mm
Depth 395 mm
Weight 10.6 kg
17.3 Physical interfaces of the I-HSPA Adapter
All external connections to the I-HSPA Adapter are made through the frontpanel.
Table 29. Physical interfaces of the I-HSPA Adapter
Front panelidentifier Purpose Interface type Connector Type
EIF1 (SFP TRS) External transport Optical for Ethernet(reserved for futureuse)
SFP, SFP cage
EIF2 (TRS/LMT) External transport/Local ManagementTerminal
10/100/1000 Base-T Ethernet
RJ45 shielded
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 79 (83)
I-HSPA Adapter description
-
Table 29. Physical interfaces of the I-HSPA Adapter (cont.)
Front panelidentifier Purpose Interface type Connector Type
EIF3 (TRS) External transport 10/100/1000 Base-T Ethernet
RJ45 shielded
EIF4 BTS interface 10/100/1000 Base-T Ethernet
RJ45 shielded
DC IN 48VDC PowerInput
Multi-Beam XL RA2 pin
Figure 39. Front panel of the I-HSPA Adapter
DC IN EIF1
EIF2 EIF3 EIF4DN70282859
80 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
18 Talk Conversion Kit (EMIA or EMIB)Flexi WCDMA BTS modules can be installed into the CityTalk cabinet byusing the Talk conversion kit EMIA or EMIB. The inner parts of the CityTalkcabinet are removed before the Flexi WCDMA modules are installed andcertain parts of the CityTalk cabinet are replaced with new parts belongingto the EMIA or EMIB kit.
The CityTalk cabinet retains its outline dimensions and the mechanicalshape when modified with EMIA or EMIB. The Flexi WCDMA BTS withinthe modified cabinet fulfils the any requirements imposed on the product.
For installation instructions, see the Installing Flexi WCDMA BTS Modulesin Cabinets document.
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 81 (83)
Talk Conversion Kit (EMIA or EMIB)
-
Figure 40. Parts needed for installing Flexi WCDMA BTS modules in Citytalkcabinet with Talk Conversion Kit EMIA
Back wall 1)
Citytalk cabinet and roof 2)
Standoff casing plate 1)
Door 1)
Upper rod lock support (2 pcs) 1)
M8 screws andwashers (4 pcs) 1)
Connection pins (4 pcs) 1)
Roof Mounting plate 2)
Air guide plate 1)
taps, clips, pins, retainingrings, and M6 screws(4 sets) 2)
screws and washers (4 pcs) 2)
Hinges (2 pcs) andscrews (8 pcs) 2) 1) Part of Talk Conversion Kit
2) Existing items of Citytalk cabinet
DN70318511
Standoff proximitybracket 1)
Doorproximitybracket 1)
82 (83) # Nokia Siemens Networks DN7086754Issue 8-2 en30/04/2009
Flexi WCDMA BTS Optional Items Description
-
Figure 41. Parts needed for installing Flexi WCDMA BTS modules in Citytalkcabinet with Talk Conversion Kit EMIB
Top support plate 1)
Top support C-plate 1)
Rack side plateLeft and right assembly 1)
Support rail (14 pcs) 1)
Door 1)
Lock cylinder 2)Lock cover 1)
Rack plinth 1)
Back wall
Top IP Cover 1)Air guide plate 1)
Citytalk cabinetand roof 2)
Upper rod locksupport (2pcs) 1)
Hinges (2 pcs) andscrews (8pcs) 2)
Standoff proximity bracket 1)
Door proximity bracket 1)
Roof mounting plate 2)
Screws and washers(4pcs) 2)
Taps, clips, pinsretaining rings and
M6 screws (4 sets) 2)
1) Part of Talk Conversion kit2) Existing items of Citytalk cabinet
DN7086754Issue 8-2 en30/04/2009
# Nokia Siemens Networks 83 (83)
Talk Conversion Kit (EMIA or EMIB)
Flexi WCDMA BTS Optional Items DescriptionContentsSummary of changes1 Flexi Mounting Kit for Floor, Wall and Pole (FMFA) description2 Pole Mounting Kit (VMPB) description3 Flexi Mounting Auxiliary Bracket (FMAA) description4 Flexi Pole Installation Kit (FPIA) description5 Flexi Pole Mounting Kit (FPKA) description6 Flexi Mounting Covers for Back and Front (FMCA and FMCB) description7 Flexi System External Alarm (FSEB) description7.1 Flexi System External Alarm Box (FSEB) operation7.2 Flexi System External Alarm (FSEB) dimensions and weight7.3 Flexi System External Alarm (FSEB) interfaces
8 Flexi System External OVP (FSEC) description9 Flexi Power Module (FPMA) and sub-modules (FPAA and FPBA) description9.1 Flexi Power Module (FPMA) and sub-modules (FPAA and FPBA) operation9.2 Flexi Power Module (FPMA) dimensions and weight9.3 Flexi Power Module (FPMA) and sub-module (FPAA and FPBA) interfaces9.4 Flexi power sub-module (FPAA and FPBA) LED indications
10 Flexi Power DC/DC Module (FPDA) description10.1 Flexi Power DC/DC Module (FPDA) operation10.2 Flexi Power DC/DC Module (FPDA) dimensions and weight10.3 Flexi Power DC/DC Module (FPDA) interfaces10.4 Flexi Power DC/DC Module (FPDA) LED indications
11 Flexi Power AC/DC sub-module (FPAB) description12 Flexi Cabinet for Indoor (FCIA) description12.1 FCIA cabinet construction12.2 FCIA optional items12.3 FCIA dimensions and weight
13 Flexi Cabinet for Outdoor (FCOA) description 13.1 Flexi Cabinet for Outdoor (FCOA) construction13.2 FCOA optional items13.3 Flexi Cabinet for Outdoor (FCOA) dimensions and weight
14 Flexi Mounting Shield (FMSA and FMSB) description14.1 Flexi Mounting Shield (FMSA and FMSB) operation and construction14.2 Flexi Mounting Shield (FMSA and FMSB) dimensions and weights
15 Flexi Mounting Kit Vertical for 2G (FMUA) description15.1 Flexi Mounting Kit Vertical for 2G (FMUA) operation15.2 Flexi Mounting Kit Vertical for 2G (FMUA) construction15.3 Technical properties of Flexi Mounting Kit Vertical for 2G (FMUA)
16 Flexi Mounting Kit Horizontal for 2G (FMUB) description16.1 Flexi Mounting Kit Horizontal for 2G (FMUB) operation and construction16.2 Technical properties of Flexi Mounting Kit Horizontal for 2G (FMUB)
17 I-HSPA Adapter description17.1 Overview of I-HSPA Adapter hardware17.2 Physical dimensions of the I-HSPA Adapter17.3 Physical interfaces of the I-HSPA Adapter
18 Talk Conversion Kit (EMIA or EMIB)