firstfloor plan groundfloor plan 2 1 1: 0 · pdf filebat hrm pas sage 2 2 0 2 7 9 0 1 1 0 0 1...
TRANSCRIPT
UP
DN
PERGOLA
KITCHEN
LOUNGEDINING ROOM
ENTRANCE
220 3410 200 3790 220 3700 220
220 2170 110 1110 8150
3610
220
6920
220
2660
800
220
2990
220
1220
1910
800
220
900
110
3200
220
1910
2660
220
3800
220
5560
220
5780
4240
1002
0
220 2170 220 1000 220 3790 220 3920
3610 4010 4140
11760
8150
3000
CARPORT
BEDROOM
BEDROOM MASTERBEDROOM
BATHRM
BATHRM
PASSAGE
220
2790
110
900
110
3010
220
220
3800
220
3120
220
2790
110
2110
110
1800
220
800
220
3100
110
1000
220
1910
800
220
1850
110
2250
220
1910
220 3500 110 3500 110 4100 220
3610 220 7930
3610 8150
220 1000110 2390 110 2480 110 5340
3610 220 1780 110 1900 220 3920
3610 4230 3920
4240
3120
7360
11760
FLASHINGS AGAINST WALLS FLASHINGS AGAINST WALLS
300mm PARAPET WALL 300mm PARAPET WALLTILES
PLASTER AND PAINT
PERGOLA
PLASTER AND PAINT
FLASHINGS AGAINST WALLS
FLASHINGS AGAINST WALLS
300mm PARAPET WALL
300mm PARAPET WALL 300mm PARAPET WALL
220mm GABLE
220mm GABLE
300mm PARAPET WALL 300mm PARAPET WALL
FLASHINGS AGAINST WALLS FLASHINGS AGAINST WALLS
TILES
PLASTER AND PAINTPLASTER AND PAINT
220mm GABLE
300mm PARAPET WALL
300mm PARAPET WALL
FLASHINGS AGAINST WALLS
PERGOLA
TILES
TILES
GENERAL NOTES:ALL CONSTRUCTION WORK TO BE DONE IN ACCORDANCE WITH THENATIONAL BUILDING REGULATION ACT, 1977 AND LOCALAUTHORITIES BY LAW.
CONTRACTOR TO VARIFY LEVELS, HEIGHTS AND DIMENTIONSON SITE AND TO CHECK SAME AGAINST DRAWINGS BEFOREPUTTING ANY WORK IN HAND.NOTE HAS TO BE TAKEN THAT IN CASE OF ANY DISCREPANCYBETWEEN CONTRACT AND DRAWING. THE CONTRACT WILL BETHE BINDING FACTOR.
THIS DRAWING IS NOTTO BE SCALED AND FIGURED DIMENTIONSTO BE USED. ASK ARCHITECT IF UNCERTAIN OF DIMENTIONS.CONTRACTOR IS RESPONSIBLE FOR SETTING OUT OF BUILDING.ALL STRUCTURAL WORK DESIGNED BY PROFFESIONALENGINEER. ALL ELECTRICAL AND PLUMBING WORK TO BECARRIED OUT BY REGISTERED ARTISANS.FINISHING TO BE OWNERS SATISFACTION.ALL WORK TO COMPLY WITH SABS STANDARD SPECIFICATIONS.ALL OPENINGS EXEEDING 2.4m SPAN TO BE SPANNEDBY PRECAST LINTOLS.
THE ARCHITECT WILL NOT BE RESPONSIBLE FOR ANY WORK DONEBEFOREPLANS HAVE BEEN APPROVED BY LOCAL AUTHORITY.
FOUNDATIONS:ALL FOUNDATIONS TO BE CAST IN VIRGIN GROUND.15Mpa CONCRETE TO BE USED. SIZE AS SHOWN.
FLOORS:25mm SCREED ON 75mm CONCRETE SURFACE BED ON WELLRAMMED HARD CORE FILLING IN LAYERS OF 150mm.FINISHED FLOOR LEVEL TO BE AT LEAST 150mm ABOVE NGL.
BELOW ALL CONCRETE SURFACE BEDS LAY 250 micronGUNDLE GUNPLAS USB GREEN WATERPROOFING MEMBRANEON 50mm CLEAN SAND ON WELL COMPACTED FILLING.
BRICKWORK:ALL EXTERNAL WALLS TO BE 220mm THICK BRICK WALLS.FOR THE MEASUREMENT OF INTERNAL WALLS REFER TO GROUNDFLOOR LAYOUT. ALL BRICKWORK BELOW FLOOR LEVEL TO BEREINFORCED WITH BRICKFORCE EVERY SECOND LAYER. ALLEXTERNAL BRICKWORK ABOVE WINDOW HEIGHT TO BE REINFORCEDWITH BRICKFORCE EVEY THIRD LAYER.
WINDOWS:WINDOWS TO HABITABLE ROOMS TO PROVIDE 10% FLOOR AREANATURAL LIGHT WITH 50% OPENINGS. BRICKFORCE AT BOTHLEVELS OF WINDOW.
GLAZING:0 - 0.75sqm = 3mm GLASS0.75 - 1.5sqm = 4mm GLASSOVER 1.5sqm = 6mm GLASSALL SLIDING DOORS TO BE FITTED WITH 6mm SHATTERPROOFGLASS WITH RECOGNITION MARKERS.ALL FIRST FLOOR WINDOWS AND STAIRWELLS TO BE FITTED WITH6mm SAFETY GLAZING AND BURGLAR BARS.
CEILING:CEILING RHINOBOARD FIXED TO 38x38mm SA PINE TIMBERBRANDERING AT 300mm CENTERS AT MAX.450mm CENTERS WITH RHINO CORNICE.NO CEILING IN GARAGE UNLESS OTHERWISE SPECIFIED.
ROOF NOTES: TRUSSESCONCRETE ROOF TILES ON 38x38mm SA PINE BATTERNS AT320mm CTS MAX. ON ROOF TRUSSES AT 760mm CTS MAX.ON 38x76 SA PINE WALLPLATES PROPERLY SECUREDWITH ROOF WIRES 2x4mm 300mm INTO BRICKWORK.ROOF PITCH TO BE AS SHOWN WITH PLASTIC UNDERLAY IFFALL IS LESS THAN 26 deg.38x152 SA PINE WG 6 TIEBEAMS.TRUSS CONSTRUCTION:ALL RIB SECTION TO BE 114x38mm SA PINE V6 GRADEALL JOINTS TO BE SECURED BY 1 @ 10mm BOLT & NUT AND75mm NAILS.
DRAINAGE:ALL WASTE FITTINGS FITTED RESEAL TAPS.NO BENDS OR JUNCTIONS PERMITTED UNDER BUILDINGS.MINIMUM FALL OF SOIL DRAINS TO BE 1:40 UNLESSOTHERWISE SHOWN ON DRAWINGS.ALL WASTE WATER PIPES TO BE MINIMUM 50mm DIAMETER.WHERE DRAINAGE PIPES CLOSER THEN 900mm FROMBUILDINGS, PIPES HAVE TO BE AT SAME LEVEL ASFOUNDATIONS.
GEYSER:GEYSER TO BE ACCORDING TO SABS 0254
SWIMMING POOL:POOL SAFTY ACC TO SABS 1390 WITH SELF CLOSINGSELF LOCKING GATES.
THE CONTRACTOR/CLEINT MAY NOT CLAIMAGAINST THE ARCHITECT AS A RESULT OPDISCREPENCIES OR ERRORS NOT REPPORTEDTO THE ARCHITECT BEFORE CONSTRUCTION
AREA SPECIFICATION:
EXISTING DWELLING:
ADDITIONS:
ERF SIZE:
COVERAGE:
PROJECT:
CLIENT:
SITE:
DRAWING:
SCALE DRAWN: DATE: CHECKED
PROJECT NO
DRAWING NO:
AS SHOWN
��������������������������������������������������������������������
J. PIETERSE T/A
KOBUS PIETERSECEL: 0828258446Professional SeniorArchitectural TechnologistH.Dip Construction supervisor
JOHAN PIETERSECEL: 0721297376N.Dip Ingenieursawese:Siviel
P.O. BOX 48420HERCULES 0030TEL/FAX: (012) 5494428
ST 0718 T 1285
VLGS NBR GED "N"
NEW DWELLING
FLOORPLAN, ELEVATIONS, SECTIONS,SITE PLAN
JOHAN 2011/04/13
001
1 : 100
GROUNDFLOOR PLAN1 1 : 100
FIRSTFLOOR PLAN2
1 : 100
NORTH ELEVATION3 1 : 100
EAST ELEVATION4
1 : 100
SOUTH ELEVATION5 1 : 100
WEST ELEVATION6
Area Schedule (Gross Building)Area Name
65 m² GROUNDFLOOR19 m² GARAGE65 m² FIRSTFLOOR148 m²