Catalogue 2017 OFFICINE DI TREVI Water supply to fixed and automatic fire fighting systems such as automatic sprinkler systems in conformity with UNI EN 12845 rules or with hydrant systems in conformity with UNI EN 10779 rules. In accordance with the different planning needs, the fire fighting systems can be composed of pumps connected to electric motors or to diesel motors. The jockey pump works only to keep the constant pressure in the system in case of small water leaks. The delivery and the head of the jockey pump can not be considered in the total calculation of the systems supply. Each main pump is controlled by an electric panel and the pump is automatically started by its pressure switch. The main pump keeps on working till the manual stop (UNI EN 12845 10.7.5.2). The main pump stops automatically when the pressure is restored. The fire fighting systems are built according to: - UNI EN 12845 – fixed fire fighting systems - automatic sprinkler systems; - UNI 10779 – fire fighting equipment- hydrant systems; - UNI EN 9906 Encl. A - Hydraulic performance acceptance tests; - 2006/42/CE Machinery Directive; - 2006/95/CE Low Voltage Directive. APPLICATIONS FEATURES OPERATING CONDITIONS Pump sets shall be housed in a closed and protected compartment (UNI EN 12845-10.3) which shall be sprinkler protected (UNI EN 12845-10.3.2) and adequately protected against freezing and secured against tampering (UNI EN 12845-8.4). Ambient temperature for electric pumps from 4°C to 40°C, max elevation 1.000 m ASL, max humidity 50% at +40°C. Temperature of pumped water max 40°C for external pumps and max 25°C for submersible pumps. The water shall be free from fibrous or other matter in suspension liable to cause accumulation in the piping system (UNI EN 12845 - 8.1.2). Water pressure shall not exceed 12 bar (except in high systems) (UNI EN 12845-8.2.1) FIRE FIGHTING SYSTEMS UNI EN 12845

Upload: haque

Post on 30-Jun-2018

249 views

Category:

Documents


0 download

TRANSCRIPT

Catalogue 2017 OFFICINE DI TREVI

Water supply to fixed and automatic firefighting systems such as automaticsprinkler systems in conformity with UNIEN 12845 rules or with hydrant systems inconformity with UNI EN 10779 rules.

In accordance with the different planningneeds, the fire fighting systems can becomposed of pumps connected to electricmotors or to diesel motors. The jockeypump works only to keep the constantpressure in the system in case of smallwater leaks. The delivery and the head ofthe jockey pump can not be considered in thetotal calculation of the systems supply.Each main pump is controlled by an electricpanel and the pump is automatically startedby its pressure switch. The main pumpkeeps on working till the manual stop (UNIEN 12845 10.7.5.2).The main pump stops automatically whenthe pressure is restored.The fire fighting systems are built accordingto:- UNI EN 12845 – fixed fire fightingsystems - automatic sprinkler systems;- UNI 10779 – fire fighting equipment-hydrant systems;- UNI EN 9906 Encl. A - Hydraulicperformance acceptance tests;- 2006/42/CE Machinery Directive;- 2006/95/CE Low Voltage Directive.

APPLICATIONS

CARATTERISTICHE

FEATURES

OPERATING CONDITIONS

Pump sets shall be housed in a closedand protected compartment (UNI EN12845-10.3) which shall be sprinklerprotected (UNI EN 12845-10.3.2) andadequately protected against freezingand secured against tampering (UNI EN12845-8.4).Ambient temperature for electric pumpsfrom 4°C to 40°C, max elevation 1.000m ASL, max humidity 50% at +40°C.Temperature of pumped water max40°C for external pumps and max 25°Cfor submersible pumps.The water shall be free from fibrous orother matter in suspension liable tocause accumulation in the pipingsystem (UNI EN 12845 - 8.1.2).Water pressure shall not exceed 12 bar(except in high systems) (UNI EN12845-8.2.1)

FIRE FIGHTING SYSTEMS UNI EN 12845

OFFICINE DI TREVI Catalogue 2017

Fire fighting systems UNI EN 12845

Catalogue 2017 OFFICINE DI TREVI

Fire fighting systems UNI EN 12845

OFFICINE DI TREVI Catalogue 2017

Fire fighting systems UNI EN 12845

Set identification code for systems with horizontal pumps

Motor power of jockey pump

Motor power of diesel pump, if present

Motor power of electric motor, if present

Pump Model

Main pump model GAX (Inox) GAG (cast iron)

1 main pump

1 main diesel pump

2 main pumps

2 main diesel pumps

1 electric pumps +1 main diesel pump

UNI EN 12845 fire fighting system