Hydraulic Manifold BlockFEA Sample 1 FEA Report April 10, 2007

XYZ Vessel Corp.123 Anytown Ontario, Canada H0H 0H0

Pressure Vessel Engineering Ltd. PVE-1343a1 of 17

Table of Contents Contents Cover Table of Contents Summary Material Properties Model - With Pipes Model - No Pipes Mesh Boundary Conditions Loads Reaction Forces Error Plots - No Pipes Displacement Plots - With Pipes Displacement Plots - No Pipes Material Stress Limits Stress Plots - With Pipes Stress Plots - No Pipes Component Cycle Life

Page 2 of 17 Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

1 2 3 4 5 6 7 8 9 10 11

FEA Analysis Summary

Page 3 of 17

Project Information:XYZ Vessel Corp. Hydraulic Manifold Block FEA Sample 1 FEA Sample 1 PVE-1343a Hyd Manifold.SLDASM Hyd Manifold.SLDDRW SolidWorks CosmosWorks 2007 10-Apr-2007 Customer Vessel Part Number Master Drawing Job FEA Model File FEA Model Drawing FEA Program Used Date

12

Design Conditions:Max Internal Pressure (psi) Max External Pressure (psi) @Temperature (F)

300Max Operating Temp (F)

0Min Operating Temp (F)

250@ Pressure (psi)

Maximum Allowed Working Pressure Maximum Design Metal Temperature

250

-20

300

13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39

Code:ASME VIII-1, 2004 EDD, 2006 ADD

Material Allowables:ASME IID, 2004 EDD, 2006 ADD

Goal:Determine if the Hydraulic Manifold Block is acceptable for use at 300 psi @ 250F according to VIII-1 rules. Due to the shape of the body ASME VIII-1 calculations are not used. ASME VIII-2 is used to interpret the results produced by the FEA. ASME VIII-1 material allowables are used.

Results:The peak stress in the Hydraulic Manifold Body is found at the junction between Port 3 and Port 4 inside the body. This peak stress is 2,949 psi. The allowable stress value for SA-479 316 stainless bar is 20,000 psi. The stress is below the membrane allowable stress.

Conclusion:The peak measured stress is less than the allowable membrane stress for the material. The design is acceptable.

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Material PropertiesDesign Pressure300.0 0.0 Oil 0.000 0.940 Design Pressure =

ver 2.01

www.pveng.com

27-Apr-07

Page 4 of 17

Hydraulic Manifold Block