failed double studded adapter (choke manifold test – 4 th test @ 10,000 psi; equipment failed)
DESCRIPTION
Failed Double Studded Adapter (Choke Manifold Test – 4 th test @ 10,000 psi; equipment failed). Rig Commissioning – Yard (Jan 28, 2010) New double studded adapter (DSA) delivered from pressure testers – ‘ready to go’ - PowerPoint PPT PresentationTRANSCRIPT
1
Failed Double Studded Adapter(Choke Manifold Test – 4th test @ 10,000 psi; equipment failed)
Rig Commissioning – Yard (Jan 28, 2010)
• New double studded adapter (DSA) delivered from pressure testers – ‘ready to go’
• Made up the equipment and readied for testing ~ failed at +/- 10,000 psi (5 minutes into a 10 minute test)
Root Cause – Failure
1. Studs not made-up to the DSA properly – had < ½” make-up
2. No equipment verification ~ both ‘long bolting / short bolting’ evident
Action – Everyone
• Trust-n-verify ~ ensure equipment is inspected & ready to go
− Question stud length anomalies (upon make-up)
• Establish & maintain buffer zones
• Ensure CoW
Barely threaded into DSA
For more information contact: Don McKelvey
1-307-413-4585
4 1/16” 10K x 2 1/16” 10K DSA