environmental monitoring program ... - … · adriana hernandez . senior environmental scientist ....

24
Report 24004630-B ENVIRONMENTAL MONITORING PROGRAM KATOOMBA WASTE MANAGEMENT FACILITY SAMPLING REPORT FOR GAS MONITORING January, February, March 2014 Report to: BMCC Locked Bag 1005 Katoomba 2780 Attn Donelda Campbell (Project Coordinator – Resource Recovery and Waste Management) Report No: 24004630-B Date: 4 th of February, 2014 Prepared by: Adriana Hernandez Adriana Hernandez Senior Environmental Scientist

Upload: trinhthu

Post on 18-Aug-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

Report 24004630-B

ENVIRONMENTAL MONITORING PROGRAM KATOOMBA WASTE MANAGEMENT FACILITY

SAMPLING REPORT FOR GAS MONITORING

January, February, March 2014

Report to: BMCC Locked Bag 1005 Katoomba 2780 Attn Donelda Campbell (Project Coordinator – Resource Recovery and Waste Management)

Report No: 24004630-B

Date: 4th of February, 2014

Prepared by: Adriana Hernandez

Adriana Hernandez Senior Environmental Scientist

Report 24004630-B

Location Building Reference CH4 Reading % v/v

Office Window near desk 0.0007

Power point under desk 0.0009

Power point near desk 0.0009

Air conditioner 0.0010

Window 2 near air conditioner 0.0009

Window 3 0.0011

Power Point near printer 0.0015

Meal Room Window (door hall) 0.0011

Power point below window (Right side) 0.0011

Power point below window (Left side) 0.0011

Air conditioner 0.0013

Power point (Air conditioner wall) 0.0013

Power point (Opposite window) 0.0012

Main Cupboard (2-Door) 0.0240

Power point (Sink) 0.0010

Toilet 1 Shower/toilet 0.0020

Drair near lockers 0.0020

Toilet Shower/toilet 0.0010

Drain/lockers 0.0011

BLUE MOUNTAINS CITY COUNCIL- KATOOMBA GAS MONITORING Sampled by M. McCracken & B. Doonan on 22nd of January, 2014

Report 24004630-B

Location Building Reference CH4 Reading % v/v

Training room Air conditioner (door) 0.0005

Power point 0.0004

Window 1 (Right hand side) 0.0004

Power point (below window) 0.0003

Window 2 (Right hand side) 0.0004

Sink Cupboard 0.0004

Sink power point 0.0004

Toilet 1 (Right hand side) 0.0004

Toilet 2 (Left hand side) 0.0004

Cupboard near toilet 0.0002

Air conditioner (Left hand side) 0.0003

Window (left hand side) 0.0003

Power point under window 0.0002

Main Recycle area Power point near hose reel 0.0004

(drop off) Shower drain below stairs 0.0003

Power point near exit door 0.0018

Power point near exit door 2 0.0037

Power point near exit door 3 0.0008

Power point downstairs wall 0.0007

Power point downstairs wall 2 0.0004

BLUE MOUNTAINS CITY COUNCIL-KATOOMBA GAS MONITORINGSampled by M. McCracken & B. Doonan on 22nd of January, 2014

Report 24004630-B

Location Building Reference CH4 Reading % v/v

Demountable on dump site Window 1 (Door side) 0.0000

Power point end wall 0.0000

Window 2 (Opposite door) 0.0000

Window 3 (Opposite door) 0.0000

Power point next to window 3 0.0000

Portable near skip bins Window door side 0.0000

Power point (end wall) 0.0000

Air conditioner (end wall) 0.0000

Power point Right hand side 0.0000

Window Right hand side 0.0000

Re-use Center Toilets-Drain Center locked up

Office window

Air conditioner

Power point under desk

Power point back wall

Power point (right hand side wall)

Conference room window

Power point behind fridge

Kitchen sink cupboard

Power point near sink

Power point back wall

Power point (side wall entrance)

BLUE MOUNTAINS CITY COUNCIL-KATOOMBA GAS MONITORINGSampled by M. McCracken & B. Doonan on 22nd of January, 2014

Report 24004630-B

Location Building Reference CH4 Reading % v/v

Gatehouse Building Cupboard wall 1 0.0000

Radio power point wall 2 0.0000

Air conditioner wall 3 0.0000

Power point wall 3 0.0000

Photocopier wall 4 0.0000

Computer wall 5 0.0000

Window wall 1 0.0000

Meeting Room Door wall 1 0.0000

Window wall 2 0.0000

Power point wall 2 0.0000

Cupboard wall 3 0.0000

Power point wall 4 0.0000

Window wall 2 0.0000

Office 1 Power point wall 4 0.0000

Hallway 1 Power point wall 1 0.0001

Kitchen Fridge power point wall 1 0.0000

Sink power point wall 2 0.0000

Sink cupboard wall 2 0.0000

Lockers wall 3 0.0000

Toilets Men's Toilets 0.0000

Ladies Toilets 0.0000

Shower locked

Sink 0.0000

Hallway 2 Power point 0.0000

BLUE MOUNTAINS CITY COUNCIL-KATOOMBA GAS MONITORINGSampled by M. McCracken & B. Doonan on 22nd of January, 2014

Report 24004630-B

Location Building Reference CH4 Reading % v/v

Re-use Shed Storage Power point (Right side wall) 0.0000

Power point (Right side wall 2) 0.0000

Power point (Back wall 1) 0.0000

Power point (Back wall 2) 0.0000

Power point (Back wall 3) 0.0000

Recycle Shed Power point front wall 0.0000

Drain (front section) 0.0000

Power point (Back wall) 0.0004

Drain (back section) 0.0010

Power point (side wall) 0.0001

Sampled by M. McCracken & B. Doonan on 22nd of January, 2014BLUE MOUNTAINS CITY COUNCIL-KATOOMBA GAS MONITORING

Report 24004740

ENVIRONMENTAL MONITORING PROGRAM KATOOMBA WASTE MANAGEMENT FACILITY

SAMPLING REPORT FOR GAS MONITORING

April, May, June 2014

Report to: BMCC Locked Bag 1005 Katoomba 2780 Attn Donelda Campbell (Project Coordinator – Resource Recovery and Waste Management)

Report No: 24004740

Date: 26th of May, 2014

Prepared by: Adriana Hernandez

Adriana Hernandez Senior Environmental Scientist

Report 24004740

Location Building Reference CH4 Reading % v/v

Office Window near desk 0.0002

Power point under desk 0.0002

Power point near desk 0.0002

Air conditioner 0.0002

Window 2 near air conditioner 0.0002

Window 3 0.0002

Power Point near printer 0.0002

Meal Room Window (door hall) 0.0005

Power point below window (Right side) 0.0002

Power point below window (Left side) 0.0002

Air conditioner 0.0006

Power point (Air conditioner wall) 0.0001

Power point (Opposite window) 0.0001

Main Cupboard (2-Door) 0.0005

Power point (Sink) 0.0002

Toilet 1 Shower/toilet 0.0008

Drair near lockers 0.0008

Toilet Shower/toilet 0.0009

Drain/lockers 0.0009

BLUE MOUNTAINS CITY COUNCIL- KATOOMBA GAS MONITORING Sampled by M. McCracken & Y. Takihara on 14th of May , 2014

Report 24004740

Location Building Reference CH4 Reading % v/v

Training room Air conditioner (door) 0.0002

Power point 0.0012

Window 1 (Right hand side) 0.0012

Power point (below window) 0.0012

Window 2 (Right hand side) 0.0012

Sink Cupboard 0.0012

Sink power point 0.0012

Toilet 1 (Right hand side) 0.0012

Toilet 2 (Left hand side) 0.0012

Cupboard near toilet 0.0013

Air conditioner (Left hand side) 0.0014

Window (left hand side) 0.0014

Power point under window 0.0013

Main Recycle area Power point near hose reel 0.0042

(drop off) Shower drain below stairs 0.0064

Power point near exit door 0.0034

Power point near exit door 2 0.0026

Power point near exit door 3 0.0026

Power point downstairs wall 0.0055

Power point downstairs wall 2 0.0075

BLUE MOUNTAINS CITY COUNCIL-KATOOMBA GAS MONITORINGSampled by M. McCracken & Y. Takihara on 14th of May , 2014

Report 24004740

Location Building Reference CH4 Reading % v/v

Demountable on dump site Window 1 (Door side) 0.0012

Power point end wall 0.0014

Window 2 (Opposite door) 0.0011

Window 3 (Opposite door) 0.0012

Power point next to window 3 0.0011

Portable near skip bins Window door side 0.0002

Power point (end wall) 0.0002

Air conditioner (end wall) 0.0002

Power point Right hand side 0.0002

Window Right hand side 0.0001

Re-use Center Toilets-Drain 0.0010

Office window 0.0009

Air conditioner 0.0009

Power point under desk 0.0010

Power point back wall 0.0010

Power point (right hand side wall) 0.0009

Conference room window 0.0008

Power point behind fridge 0.0009

Kitchen sink cupboard 0.0009

Power point near sink 0.0009

Power point back wall 0.0009

Power point (side wall entrance) 0.0009

BLUE MOUNTAINS CITY COUNCIL-KATOOMBA GAS MONITORINGSampled by M. McCracken & Y. Takihara on 14th of May , 2014

Report 24004740

Location Building Reference CH4 Reading % v/v

Gatehouse Building Cupboard wall 1 0.0027

Radio power point wall 2 0.0029

Air conditioner wall 3 0.0021

Power point wall 3 0.0024

Photocopier wall 4 0.0021

Computer wall 5 0.0027

Window wall 1 0.0027

Meeting Room Door wall 1 0.0024

Window wall 2 0.0024

Power point wall 2 0.0025

Cupboard wall 3 0.0025

Power point wall 4 0.0025

Window wall 2 0.0024

Office 1 Power point wall 4 0.0026

Hallway 1 Power point wall 1 0.0024

Kitchen Fridge power point wall 1 0.0026

Sink power point wall 2 0.0026

Sink cupboard wall 2 0.0024

Lockers wall 3 0.0024

Toilets Men's Toilets 0.0031

Ladies Toilets 0.0031

Shower locked

Sink 0.0025

Hallway 2 Power point 0.0025

BLUE MOUNTAINS CITY COUNCIL-KATOOMBA GAS MONITORINGSampled by M. McCracken & Y. Takihara on 14th of May , 2014

Report 24004740

Location Building Reference CH4 Reading % v/v

Re-use Shed Storage Power point (Right side wall) 0.0024

Power point (Right side wall 2) 0.0022

Power point (Back wall 1) 0.0021

Power point (Back wall 2) 0.0022

Power point (Back wall 3) 0.0021

Recycle Shed Power point front wall 0.0020

Drain (front section) 0.0048

Power point (Back wall) 0.0019

Drain (back section) 0.0031

Power point (side wall) 0.0011

Sampled by M. McCracken & Y. Takihara on 14th of May , 2014BLUE MOUNTAINS CITY COUNCIL-KATOOMBA GAS MONITORING

Report 24004865

ENVIRONMENTAL MONITORING PROGRAM KATOOMBA WASTE MANAGEMENT FACILITY

SAMPLING REPORT FOR GAS MONITORING

July, August, September 2014

Report to: BMCC Locked Bag 1005 Katoomba 2780 Attn Donelda Campbell (Project Coordinator – Resource Recovery and Waste Management)

Report No: 24004865-B

Date: 18th of September, 2014

Prepared by: Adriana Hernandez

Adriana Hernandez Senior Environmental Scientist

Report 24004865

Location Building Reference CH4 Reading % v/v

Office Window near desk 0.0238

Power point under desk 0.0256

Power point near desk 0.0240

Air conditioner 0.0240

Window 2 near air conditioner 0.0226

Window 3 0.0221

Power Point near printer 0.0271

Meal Room Window (door hall) 0.0290

Power point below window (Right side) 0.0250

Power point below window (Left side) 0.0250

Air conditioner 0.0250

Power point (Air conditioner wall) 0.0237

Power point (Opposite window) 0.0240

Main Cupboard (2-Door) 0.0140

Power point (Sink) 0.0210

Toilet 1 Shower/toilet 0.0018

Drair near lockers 0.0019

Toilet Shower/toilet 0.0034

Drain/lockers 0.0044

BLUE MOUNTAINS CITY COUNCIL- KATOOMBA GAS MONITORING Sampled by J. Takihara & L. Stapleton on 9th of September , 2014

Report 24004865

Location Building Reference CH4 Reading % v/v

Training room Air conditioner (door) 0.0260

Power point 0.0277

Window 1 (Right hand side) 0.0228

Power point (below window) 0.0290

Window 2 (Right hand side) 0.0242

Sink Cupboard 0.0293

Sink power point 0.0266

Toilet 1 (Right hand side) 0.0067

Toilet 2 (Left hand side) 0.0054

Cupboard near toilet 0.0205

Air conditioner (Left hand side) 0.0265

Window (left hand side) 0.0219

Power point under window 0.0222

Main Recycle area Power point near hose reel 0.0150

(drop off) Shower drain below stairs 0.0700

Power point near exit door 0.0180

Power point near exit door 2 0.0144

Power point near exit door 3 0.0144

Power point downstairs wall 0.0100

Power point downstairs wall 2 0.0050

BLUE MOUNTAINS CITY COUNCIL-KATOOMBA GAS MONITORINGSampled by J. Takihara & L. Stapleton on 9th of September , 2014

Report 24004865

Location Building Reference CH4 Reading % v/v

Demountable on dump site Window 1 (Door side) 0.0000

Power point end wall 0.0000

Window 2 (Opposite door) 0.0000

Window 3 (Opposite door) 0.0000

Power point next to window 3 0.0000

Portable near skip bins Window door side 0.0000

Power point (end wall) 0.0000

Air conditioner (end wall) 0.0000

Power point Right hand side 0.0000

Window Right hand side 0.0000

Re-use Center Toilets-Drain 0.0019

Office window 0.0287

Air conditioner 0.0250

Power point under desk 0.0260

Power point back wall 0.0239

Power point (right hand side wall) 0.0250

Conference room window 0.0221

Power point behind fridge 0.0230

Kitchen sink cupboard 0.0214

Power point near sink 0.0191

Power point back wall 0.0203

Power point (side wall entrance) 0.0295

BLUE MOUNTAINS CITY COUNCIL-KATOOMBA GAS MONITORINGSampled by J. Takihara & L. Stapleton on 9th of September , 2014

Report 24004865

Location Building Reference CH4 Reading % v/v

Gatehouse Building Cupboard wall 1 0.0005

Radio power point wall 2 0.0003

Air conditioner wall 3 0.0003

Power point wall 3 0.0004

Photocopier wall 4 0.0004

Computer wall 5 0.0004

Window wall 1 0.0005

Meeting Room Door wall 1 0.0001

Window wall 2 0.0000

Power point wall 2 0.0003

Cupboard wall 3 0.0003

Power point wall 4 0.0003

Window wall 2 0.0002

Office 1 Power point wall 4 0.0005

Hallway 1 Power point wall 1 0.0005

Kitchen Fridge power point wall 1 0.0002

Sink power point wall 2 0.0002

Sink cupboard wall 2 0.0002

Lockers wall 3 0.0001

Toilets Men's Toilets 0.0005

Ladies Toilets 0.0004

Shower locked

Sink 0.0004

Hallway 2 Power point 0.0004

BLUE MOUNTAINS CITY COUNCIL-KATOOMBA GAS MONITORINGSampled by J. Takihara & L. Stapleton on 9th of September , 2014

Report 24004865

Location Building Reference CH4 Reading % v/v

Re-use Shed Storage Power point (Right side wall) 0.0023

Power point (Right side wall 2) 0.0025

Power point (Back wall 1) 0.0026

Power point (Back wall 2) 0.0025

Power point (Back wall 3) 0.0025

Recycle Shed Power point front wall 0.0029

Drain (front section) 0.0030

Power point (Back wall) 0.0031

Drain (back section) 0.0029

Power point (side wall) 0.0030

Sampled by J. Takihara & L. Stapleton on 9th of September , 2014BLUE MOUNTAINS CITY COUNCIL-KATOOMBA GAS MONITORING

ENVIRONMENTAL MONITORING PROGRAM KATOOMBA WASTE MANAGEMENT FACILITY

SAMPLING REPORT FOR GAS MONITORING

October, November and December 2014

Report to: BMCC Locked Bag 1005 Katoomba 2780 Attn Donelda Campbell (Project Coordinator – Resource Recovery and Waste Management)

Report No: 24004983

Date: 26th of November, 2014

Prepared by: Natalie McMillan

Natalie McMillan

Environmental Supervisor

Report 24004983

Location Building Reference CH4 Reading % v/v

Office Window near desk 0.0015

Power point under desk 0.0017

Power point near desk 0.0015

Air conditioner 0.0015

Window 2 near air conditioner 0.0016

Window 3 0.0016

Power Point near printer 0.0017

Meal Room Window (door hall) 0.0021

Power point below window (Right side) 0.0022

Power point below window (Left side) 0.0021

Air conditioner 0.0023

Power point (Air conditioner wall) 0.0021

Power point (Opposite window) 0.0022

Main Cupboard (2-Door) 0.0060

Power point (Sink) 0.0044

Toilet 1 Shower/toilet 0.0036

Drair near lockers 0.0036

Toilet Shower/toilet 0.0025

Drain/lockers 0.0022

BLUE MOUNTAINS CITY COUNCIL- KATOOMBA GAS MONITORING Sampled by L. Stapleton & N. Unsworth on 14th of November , 2014

Report 24004983

Location Building Reference CH4 Reading % v/v

Training room Air conditioner (door) 0.0009

Power point 0.0006

Window 1 (Right hand side) 0.0006

Power point (below window) 0.0004

Window 2 (Right hand side) 0.0005

Sink Cupboard 0.0004

Sink power point 0.0004

Toilet 1 (Right hand side) 0.0005

Toilet 2 (Left hand side) 0.0007

Cupboard near toilet 0.0005

Air conditioner (Left hand side) 0.0006

Window (left hand side) 0.0004

Power point under window 0.0002

Main Recycle area Power point near hose reel 0.0220

(drop off) Shower drain below stairs 0.0088

Power point near exit door 0.0030

Power point near exit door 2 0.0008

Power point near exit door 3 0.0008

Power point downstairs wall 0.0128

Power point downstairs wall 2 0.0145

BLUE MOUNTAINS CITY COUNCIL-KATOOMBA GAS MONITORINGSampled by L. Stapleton & N. Unsworth on 14th of November , 2014

Report 24004983

Location Building Reference CH4 Reading % v/v

Demountable on dump site Window 1 (Door side) 0.0000

Power point end wall 0.0000

Window 2 (Opposite door) 0.0000

Window 3 (Opposite door) 0.0000

Power point next to window 3 0.0000

Portable near skip bins Window door side 0.0037

Power point (end wall) 0.0035

Air conditioner (end wall) 0.0035

Power point Right hand side 0.0034

Window Right hand side 0.0034

Re-use Center Toilets-Drain 0.0000

Office window 0.0028

Air conditioner 0.0028

Power point under desk 0.0030

Power point back wall 0.0029

Power point (right hand side wall) 0.0028

Conference room window 0.0031

Power point behind fridge 0.0000

Kitchen sink cupboard 0.0000

Power point near sink 0.0027

Power point back wall 0.0027

Power point (side wall entrance) 0.0028

BLUE MOUNTAINS CITY COUNCIL-KATOOMBA GAS MONITORINGSampled by L. Stapleton & N. Unsworth on 14th of November , 2014

Report 24004983

Location Building Reference CH4 Reading % v/v

Gatehouse Building Cupboard wall 1 0.0007

Radio power point wall 2 0.0006

Air conditioner wall 3 0.0007

Power point wall 3 0.0007

Photocopier wall 4 0.0004

Computer wall 5 0.0004

Window wall 1 0.0004

Meeting Room Door wall 1 0.0014

Window wall 2 0.0014

Power point wall 2 0.0013

Cupboard wall 3 0.0014

Power point wall 4 0.0014

Window wall 2 0.0013

Office 1 Power point wall 4 0.0012

Hallway 1 Power point wall 1 0.0011

Kitchen Fridge power point wall 1 0.0011

Sink power point wall 2 0.0010

Sink cupboard wall 2 0.0008

Lockers wall 3 0.0010

Toilets Men's Toilets 0.0010

Ladies Toilets 0.0010

Shower locked

Sink 0.0008

Hallway 2 Power point 0.0009

BLUE MOUNTAINS CITY COUNCIL-KATOOMBA GAS MONITORINGSampled by L. Stapleton & N. Unsworth on 14th of November , 2014

Report 24004983

Location Building Reference CH4 Reading % v/v

Re-use Shed Storage Power point (Right side wall) 0.0058

Power point (Right side wall 2) 0.0055

Power point (Back wall 1) 0.0052

Power point (Back wall 2) 0.0045

Power point (Back wall 3) 0.0043

Recycle Shed Power point front wall 0.0003

Drain (front section) 0.0006

Power point (Back wall) 0.0002

Drain (back section) 0.0007

Power point (side wall) 0.0002

Sampled by L. Stapleton & N. Unsworth on 14th of November , 2014BLUE MOUNTAINS CITY COUNCIL-KATOOMBA GAS MONITORING

Report 24004983