Eni 750 Tech Info

Download Eni 750 Tech Info

Post on 05-Mar-2015

53 views

Category:

Documents

0 download

Embed Size (px)

TRANSCRIPT

<p>ENI 750 BILL OF MATERIAL UNIT S/N__________ DESCRIPTIONKATOLIGHT PROVIDED MATERIAL Engine/Generating Set Generator Digital Voltage Regulator Governor System Digital Genset Controller Circuit Breaker Battery Rack Water Heater ALPHA PROVIDED MATERIAL ENCLOSURE Outdoor Sound Enclosures (60 &amp; 69 dBA) Exhaust System Silencer Style 1 Silencer Style 2 Flex Connector Silencer Outlet Extension Rain Cap Rain Guard Bolts, Nuts and Gasket Misellaneous Bolts, Nuts and Gasket Vibration Mounts Sheet Metal Wall Panels Sheet Metal Roof Beams 4.0" x 4.0" Square Structural Channel 2.0" x 2.0" x 0.25 Angle Iron Perforated Steel Liner Sheets Wall and Ceiling Insulation - 4" Thinkness Fixed Louver - Intake Fixed Louver - Exhaust Motorized Dampers Damper Motors Damper Hardware Sound Attenuator Packs Sound Attenuator Packs (add for 60 dBA) 14 and 12 Gauge Sheet Galvaneal Sub-base Fuel Tank(w/NYC cert.) Fuel level switches Fuel fill alarm box Nuts, Bolts and Screws Alpha Power Systems EM Products EM Products EM Products EM Products EM Products EM Products EM Products EM Products Isolation Technology Wymore Wymore N/A DHK, 12"x86"DIAx22"H DHK, 12"x86"DIAx22"H FL10-19MIT-08 EXT-12-24 RC-000646 RGS-12 BNG-10 BNG-12 CK2-S8-2600 1 1 1 1 1 1 1 1 1 10 as req'd as req'd as req'd as req'd as req'd as req'd 1 1 2 4 UL, CSA 4 2 2 1 UL, NFPA, NYC 3 UR 1 as req'd N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A</p> <p>MANUFACTURERKatolight Marathon Marathon Barbar Colman Katolight Katolight Katolight Katolight</p> <p>PART NO.ENRD750FRY4 573RSL4032 DVR2000E DYN1-10656-000-0-24 KDGC-2000 TKMA322100WL 204-169 CL140210-000</p> <p>QTY/U NIT1 1 1 1 1 1 1 2</p> <p>CERTIFICATIONSUL, CSA ULR, CSA, CE ULR, CSA UL, CSA</p> <p>S/N</p> <p>N/A CSA</p> <p>Ventex 2435-4 Ventex 2415-4 Ventex Model 3160 Belimo Belimo Kinetics Kinetics Sauk Technologies Gems APS</p> <p>78"W x 96"H x 4"D 78"W x 96"H x 4"D 78"W x 96"H x 4"D AF120 78"W x 96"H x 72"D 78"W x 96"H x 36"D UCTSC-1100 LS1700</p> <p>N/A</p> <p>CERTIFICATION CODES UL - UL LIsted Component, ULR - UL Recognized Component, CSA - CSA Certified Component, CE - CE Marked Component, NYC - meets NYC code, NFPA meets NFPA code</p> <p>ENI 750 BILL OF MATERIAL UNIT S/N__________ DESCRIPTIONPiping and Fittings Fill Cap High Pressure Hose and Swag Fittings Door Handles and Fittings 6" pressure relief vent cap ELECTRICAL HARDWARE Load Center, Class 1130, Indoor, 25KAIC, 125 AF Main Breaker, 120/208 VAC 22 KAIC, 15A, 3P Breaker 22 KAIC, 20A, 3P Breaker 22 KAIC, 30A, 3P Breaker 22 KAIC, 15A, 1P Breaker 22 KAIC, 20A, 1P Breaker Seal Tight Conduit and Fittings Rigid Conduit and Fittings I-Beam Conduit Hanger Terminal Blocks End Plates Jumpers Earth/Gnd Terminal Blocks Sticky Blocks Start/Control Battery Battery Charger Battery Box Male Battery Terminal, Crimp Style Female Battery Terminal, Crimp Style Camlock Connector, Female, Set Screw Camlock Connector, Female, Set Screw Camlock Connector, Female, Set Screw Camlock Connector, Female, Set Screw Camlock Connector, Female, Set Screw Camlock Connector - Cover Interior lights, switches, and receptacles Power Cable Other control &amp; electrical wire SQ D SQ D SQ D SQ D SQ D SQ D QO330MQ125 QO315VH QO320VH QO330VH QO115VH QO120VH 1 as req'd as req'd as req'd as req'd as req'd as req'd as req'd as req'd as req'd as req'd as req'd as req'd as req'd 4 1 4 as req'd as req'd 4 4 4 4 4 1 as req'd as req'd as req'd UL UL, CSA UL, CSA UL, CSA UL, CSA UL, CSA N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A</p> <p>MANUFACTURER</p> <p>PART NO.</p> <p>QTY/U NITas req'd 1 as req'd as req'd 2</p> <p>CERTIFICATIONS</p> <p>S/NN/A N/A N/A N/A</p> <p>Sauk Technologies</p> <p>2160</p> <p>Wago Wago Wago Wago Battery Plus Sens NOCO Marine 8DA FC-24-20-2031U HM484</p> <p>UL N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A</p> <p>Camlock Crouse-Hinds Camlock Crouse-Hinds Camlock Crouse-Hinds Camlock Crouse-Hinds Camlock Crouse-Hinds Camlock Crouse-Hinds General Cable</p> <p>E1016-1700, BLK, PHA E1016-1702, RED, PHB E1016-1705, WHT, PHC E1016-1700, BLU, NEUT. E1016-1704, GRN, GND. A-100602-1</p> <p>UL, CSA UL, CSA UL, CSA UL, CSA UL, CSA</p> <p>UL, CSA per NEC code</p> <p>CERTIFICATION CODES UL - UL LIsted Component, ULR - UL Recognized Component, CSA - CSA Certified Component, CE - CE Marked Component, NYC - meets NYC code, NFPA meets NFPA code</p> <p>Diesel T1</p> <p>750 kW @ 60 Hz. Stand-By Power</p> <p>D750F*Y4</p> <p>680 kW @ 60 Hz. Prime Power</p> <p> Katolights commitment to quality has been an industry standard since 1952 Katolight specializes in custom designing any application to meet the most difficult specifications Each and every unit is factory tested. This can eliminate costly startup and installation delays Katolight supplies a broad range of accessories to match any requirement worldwide Katolight generator sets come standard with a 2 year, 1500 hour limited warranty Optional warranty periods are also available, contact factory for details This model accepts 100% of nameplate rating, per NFPA 110 This engine is EPA Tier I certifiedModel # Volts Hz Phase Power Factor Standby Ratings Amps kW/kVA Prime Ratings Amps kW/kVA Connection</p> <p>D750FRY4 D750FPY4 D750FJY4 D750FNY4</p> <p>277/480 120/208 120/240 347/600</p> <p>60 60 60 60</p> <p>3 3 3 3</p> <p>0.8 0.8 0.8 0.8</p> <p>1128 2255 2602 902</p> <p>750/937.5 750/937.5 750/937.5 750/937.5</p> <p>1022 2045 2359 818</p> <p>680/850 680/850 680/850 680/850</p> <p>12 LEAD HI WYE 12 LEAD LOW WYE 12 LEAD HI DELTA 4 LEAD WYE</p> <p>D750FRY4_05-05</p> <p>D750F*Y4 DIESEL Gen-Set</p> <p>STANDARD EQUIPMENTCONTROL PANELModel #45 control panel AC voltmeter, 3 , 2% accuracy AC ammeter, 3 , 2% accuracy Combination VM/AM selector switch, 4 position Frequency meter, 3 , 55-65 Hz. Vibration shock mounts (4) Engine control - KASSEC-24 VDC, with cyclic cranking timer 4 engine shutdowns with separate failure lights High water temperature Low oil pressure Engine overspeed Engine overcrank Engine gauges - 2" Battery voltmeter Water temperature Oil pressure Running time meter - 5 digits 3 position mode switch (auto-off-manual)</p> <p>ENGINE (cont.)Governor Electric Isochronous Base - formed steel Flywheel &amp; Enclosure Charging alternator - 24V Battery box &amp; cables Flexible fuel &amp; exhaust connectors EPA Certified Engine</p> <p>GENERATORA.C. Generator Brushless design Single bearing Direct connection with flex plate Class H insulation All models manufactured to meet NEMA MG1- 22.4 and CSA standards Telephone influence factor is well within NEMA standards Wave form deviation factor is no more than 5%, well within NEMA standards Harmonic content is 3.0% maximum Permanently lubricated ball type bearings Generator is self-ventilated Drip-proof construction</p> <p>ENGINEAir cleaner Oil pump Full flow oil filter Jacket water pump Thermostat Exhaust manifold dry Blower fan &amp; fan drive Radiator - unit mounted Vibration isolators - pad type Electric starting motor - 24V</p> <p>VOLTAGE REGULATORVoltage adjust rheostat EMI filter (Internal Electromagnetic Interference) Underspeed protection Overexcitation protection Fully encapsulated Regulation - 0.25%</p> <p>Drawing above for illustration purposes only, based on standard open power 480 volt generator. Lengths may vary with other voltages.</p> <p>D750F*Y4 Diesel Gen-Set</p> <p>ENGINE TECHNICAL DATA</p> <p>60 Hz</p> <p>Model:.................................................................................................................... S12A2-Y1PTA-1 Type: ............................................................................................................................ 4-Cycle Aspiration: ...................................................................................................... Turbocharged Aftercooled Cylinder Arrangement: (Number, inline, V, etc.) ...............................................................12-V Displacement - Cu. In. (lit) .........................................................................................2,071 (33.9) Bore - in. (cm) x stroke - in. (cm)....................................................................... 5.91 (15.0) x 6.3 (16.0) Compression Ratio: ....................................................................................................... 15.3:1 Rated RPM..................................................................................................................... 1800 Rating Standby Prime BMEP: psi (kPa) .............................................................................256 (1,765) ............................................234 (1,613) Maximum Power at Rated RPM - bhp(kW)......................................1,207 (900) ............................................1,099 (820)</p> <p>INSTALLATION DATA *Exhaust SystemGas Temp. (Stack): F ( .................................................. 820 (438) ................................................686(363) C) Gas Volume at Stack Temp.: CFM (m3/min)................................7,353 (208) ............................................6,980 (198) Maximum Allowable Back Pressure: in. H20 (kPa) ........................................... 23.6 (5.9) ............................................... 23.6 (5.9)</p> <p>Cooling SystemAmbient Capacity of Radiator: F ( C)........................................ 100 (38) ................................................. 100 (38) Maximum Allowable Static Pressure on Rad. Exhaust: in. H2O (kPa)................................... 0.5 (0.12) ............................................... 0.5 (0.12) Water Pump Capacity: gpm (lit/min)............................................291 (1,100) ............................................291 (1,100) Heat Rejection to Coolant: BTUM (kW).......................................33,740 (593)...........................................29,987 (527) Heat Radiated to Ambient: BTUM (kW)........................................7,316 (129) ............................................6,481 (114)</p> <p>Air Requirements</p> <p>Aspirating: CFM (m3/min) ....................................2,912 (82) ..............................................2,600 (74) Air Flow Required for Rad. Cooled Unit: CFM (m3/min)................................. 40,267 (1,140) ....................................... 40,267 (1,140) Air Flow Required for Heat Exchanger/Remote Rad. based on 20 Rise: F CFM (m3/min).................................20,322 (575)...........................................18,003 (510) At 100% of Power Rating: gal/hr At 75% of Power Rating: gal/hr At 50% of Power Rating: gal/hr (lit/hr)....................................64.9 (246) ..............................................59.8 (226) (lit/hr)....................................49.8 (189) ..............................................45.7 (173) (lit/hr)....................................33.1 (125) ..............................................31.6 (120)</p> <p>Fuel Consumption:</p> <p>Sound Level Data Sound level at: Full Load No Load Full Load No Load 23 ft (7m) opu w/ critical grade muffler (dBA) .......................92 ................................ 90 ............................. 91 ........................ 90 23 ft (7m) Sound Attenuated Enclosure (dBA) .....................88 ................................ 86 ............................. 87 ........................ 86</p> <p>Dimensions &amp; WeightLength: in. (cm)....................................................... 155 (394) Width: in. (cm) .........................................................63 (160) Height: in. (cm) .........................................................83 (211) Weight (dry): lb. (kg) ........................................ 13,550 (6,146)</p> <p>Fuel System</p> <p>Liquid CapacityTotal oil system: gal (lit) ........................................... 31.7 (120) Engine jacket water capacity: gal (lit) ....................... 26.4 (100) System coolant capacity: gal (lit).................................68 (257)</p> <p>Fuel Supply Connection Size: ................................. 3/4 NPT Fuel Return Connection Size: ................................. 3/4 NPT Maximum Fuel Lift: ft (m) ............................................. 3 (1) Recommended Fuel:............................................. Diesel #2 Total Fuel Flow: gal/hr (lit/hr).................................166 (630) Connection sizes: Jacket water radiator inlet in. (cm)...........................4 (10.2) Jacket water radiator outlet in. (cm) .........................4 (10.2) Static head allowable above engine: ft H2O (kPa) ..................................32.8 (98)</p> <p>Remote Radiator System</p> <p>Electrical SystemElectric volts DC .................................................................. 24 Cold cranking Amps under 0 (-17.8 ........................................................ 1,250 F C)</p> <p>*Installation data based on 480 volt, 60 HZ. application and open power unit. For sound level readings with other enclosures, please contact factory. Sound level data acquired per Test Method SAE J1074. Installation factors and site conditions can affect sound levels. Deration Factor: Altitude: Derate: 2.5% per 984 ft (300m) above 4,921 ft (1,500 m). Temperature: Derate: 4% per 18oF (10oC) above 104oF (40oC)</p> <p>D750F*Y4 Diesel Gen-Set Control Panel Fuel System o Fuel Water Seperator o Day Tank o Above Ground Fuel Tank o Auxillary Fuel Pump o Sub-Base mounted Fuel Tank o Single Wall o Double Wall o UL Listed Exhaust System o Residential Grade Muffler o Critical Grade Muffler o Hospital Grade Muffler o Rain Cap Engine Electrical System o Battery o Lead-Acid o Nicad o Battery Warmer Plate o Battery Rack o Battery Charger o Automatic o Trickle o Mounted &amp; Wired Generator o Main Line Circuit Breaker o Shunt trip o Auxiliary switch o PMG Excitation &amp; DVR 2000 Regulator o Space Heaters 120/240 volt o Special Testing o Additional Temperature Rise GeneratorsAvailable (80C, 105C, &amp; 130C)</p> <p>** NOTE: #45 series control panel is standard on all units, see page 2 of spec sheet for standard features. o Model #45 Series Control Panel Options o Emergency stop button o Alarm buzzer with silencing switch o Auxiliary relay for dry contacts (2 max.) o A separate low water level light is optional o Hooded panel lights (2) and on/off switch o NEMA 12 Panel Face o Additional LED lights (4 max.) One or two of the following conditions may be indicated: unit not in auto low fuel level low water level low water temp. EPS supplying load pre-alarm oil pre-alarm temp. charger malfunction o Model #50 Series Control Panel STANDARD FEATURES: same as #45 series control panel except for these added features: o Hooded panel lights (2) and on/off switch o 4 Engine shutdowns o 12 light engine control package meeting NFPA110 requirement o Repetitive alarm buzzer and silencing switch o Light and alarm press to test #50 SERIES OPTIONS o Emergency stop button o Additional space for one 31/2 meter o Auxiliary relay for dry contacts (2 max.) o A separate low water level light is optional o Additional LED lights (4 max.) One to four additional conditions may be indicated: customer to specify o NEMA 12 Panel Face o Model #60 and #80 Series Cus...</p>