Elite Electronic Engineering Inc. Commercial Aviation + Military EMC Testing Services One-Stop Testing Completed Accurately and on Your Schedule.

Upload: lamque

Post on 07-Jul-2018

225 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Elite Electronic Engineering Inc. Commercial Aviation ... · Elite Electronic Engineering Inc. Elite is a leader in providing EMC and environmental stress testing services to the

Elite Electronic Engineering Inc.

Commercial Aviation+MilitaryEMCTesting Services

One-Stop Testing Completed Accurately and on Your Schedule.

Page 2: Elite Electronic Engineering Inc. Commercial Aviation ... · Elite Electronic Engineering Inc. Elite is a leader in providing EMC and environmental stress testing services to the

Elite Electronic Engineering Inc.

Elite is a leader in providing EMC and

environmental stress testing services

to the commercial aviation and military

industry. Our test and consulting engineers

assist manufacturers of aircraft avionics,

military equipment, and vehicles to comply

with rigorous governmental requirements

and OEM specifications.

The Elite Advantage• Expertise — Elite is an industry leader with a name

highly regarded in the aviation and military industry.

Testing with Elite means our test results and reports

are readily accepted and approved by OEMs along

with aviation and defense agencies.

• Trust — With more than 60 years of EMC services,

you can count on Elite to get the job done right,

and on time.

• Accreditations and Credentials — Elite is ISO17025

accredited to provide independent verification

of our processes, staff credentials, and capabilities.

We have many iNARTE Certified Engineers and

qualify as an iNARTE Test Lab.

• Scheduling and Convenience — As one of the

largest EMC labs in North America, we are configured

for responsive scheduling. And with a full capability

Environmental Stress Test Laboratory, we provide the

convenience of one-stop for all your qualification

needs.

What Makes Elite the Preferred Choice?

Range of Services

MIL, Aero, Auto, Commercial, Wireless

• RTCA DO-160 through Revision G, Boeing

D6-16050-4, Airbus ABD, Embraer, Bombardier

• MIL-STD-461/462 — Revision G, F, E, D, C, B, and A

• DEF-STAN-59-41 — U.K. Military EMC Spec

• MIL-STD-704, 1275, 1399 — Power Systems Testing

• Lockheed, Boeing, Airbus, and other OEM

Specifications

Unique Capabilities

• Test Plan Development — Fully Developed Aviation

or Military Test Plans/Procedures

• HIRF, Lightning, EMP (MIL-461 RS105) Test Services

• Whole Vehicle EMC Testing

• Large Walk-in Temperature Chamber for Electrical

Testing at Temperature

• Customized Support and Load Equipment

Development

Special Utilities

• Readily available AC (60Hz/400Hz) and DC Power

• LISNs (DC-480V 3phase) up to 200 Amps

• Waveguide, Filtered, or Fiber Optic Interfaces on

RF Test Chambers

• Compressed Air: 90PSI, 150CFM, Refrigeration

Dried; Cooling Water: 30PSI, 7GPM

• Forklifting Capabilities up to 15,000 lb

Page 3: Elite Electronic Engineering Inc. Commercial Aviation ... · Elite Electronic Engineering Inc. Elite is a leader in providing EMC and environmental stress testing services to the

CHAMBER GROUND ID DIMENSIONS PLANE TYPE

L W H L W

11 19´ 20´ 14´ 16´ 6´ Semi-Anechoic

12 20´ 15´ 10´ 16´ 6´ Semi-Anechoic

14L 21´ 19´ 16´ 16´ 4´ Reverberation

14S 10´ 8´ 8´ 7.5´ 4´ Reverberation

16 19´ 20´ 12´ 20´ 7´ Semi-Anechoic

17 24´ 10´ 10´ 9´ 3.5´ Semi-Anechoic

19 19´ 20´ 12´ 16´ 4´ Semi-Anechoic

21 32´ 20´ 18´ Semi-Anechoic

22 70´ 33´ 18´ Semi-Anechoic

23 31´ 23´ 18´ 31´ 6´ Semi-Anechoic

23P 15´ 12´ 10´ 15´ 3´ Shielded Room

24 16´ 12´ 10´ 9´ 2.5´ Reverberation

25 23.5´ 21.5´ 14´ 16´ 5.5´ Semi-Anechoic

26 16´ 12´ 10´ 11.5´ 4´ Shielded Room

27 23´ 21.5´ 14´ 11´ 5´ Semi-Anechoic

28 16´ 12´ 10´ 10´ 4´ Shielded Room

29 32´ 20´ 18´ 10´ 4´ Semi-Anechoic

Elite EMC Chambers

We offer test chambers in various configurations, sizes,

absorber linings, power supplies, and monitoring systems

that can be tailored to your exact testing needs.

Elite’s EMC Test Chamber 12 Semi-Anechoic Shielded Test Enclosure Primary Testing Uses: MIL-STD and DO-160

Elite’s EMC Test Chamber 22 Semi-Anechoic Shielded Whole Vehicle Test Enclosure Primary Testing Uses: Automotive and MIL-STD

Elite’s Electromagnetic Pulse (EMP) simulator is designedto test in accordance with MIL-STD-461 RS105 at pulseamplitudes in excess of 50,000V/m.

Elite Radiated Susceptibility (and HIRF) Capabilities

Actual field intensity may be affected by test item loading.

Range (MHz) Elite’s Field Intensity (V/m) Elite’s Field Intensity (V/m)

400 – 1000 1000 (CW, SW, AM & PM) 1000 (CW, SW, AM & PM)

1000 – 4000 800 (CW, SW) 4000 (PM) 800 (CW, SW) 5000 (PM)

4000 – 8000 800 (CW, SW) 4000 (PM) 800 (CW, SW) 6000 (PM)

8000 – 18000 800 (CW, SW) 4000 (PM) 800 (CW, SW) 5000 (PM)

18000 – 26500 600 (CW, SW, PM) 600 (CW, SW, PM)

26500 – 40000 400 (CW, SW, PM) 400 (CW, SW, PM)

˜̃ ˜̃

Page 4: Elite Electronic Engineering Inc. Commercial Aviation ... · Elite Electronic Engineering Inc. Elite is a leader in providing EMC and environmental stress testing services to the

The one-stop testing experience that gets your products to market efficiently and cost effectively.

To find out more: www.elitetest.com | 1-800-354-8311

Elite Induced Effects Lightning Capabilities

Elite has the expertise and equipment to apply DO-160

Section 22 Secondary Effects Lightning transients including

single stroke (SS), multi-burst (MB), and multi-stroke (MS)

pulses. Elite can apply all RTCA DO-160 waveforms at

Level 5. Other specifications include MIL-461G CS117,

Boeing D6-16050-4, and Airbus ABD0100.1.2.

• Pin Test Waveforms and Levels:

· Single Stroke and Multiple Stroke all waveforms to Level 5

· Ex, DO-160G Waveforms 2, 3, 4, 5a (Level 5)

• Cable Induction & Cable Injection Methods:

· Multiple Burst —Waveform 3 and Waveform 6 capability

· Waveform 3 or 6 multiple burst threat to Level 5

Note: Elite has two Thermo Scientific ECAT Lightning Test Systems.Contact Elite for other customized lightning and surge waveformsand testing.

Programmable and Steady State

Power Capabilities

Elite power supply systems are configured for

DO-160 Sec 16, MIL-HDBK-704, MIL-1275, Boeing

Elite’s lightning capabilities include pin injection, cable injection, and ground injection. With our large coupling probes Elite can cable inject WF4 and WF5A current or voltage transients up to Level 5.

3-phase AC

(30kVA)

40-5000Hz

Single phase AC

(30kVA)

40-5000Hz

DC: (30kVA)

208VAC 84A/phase

156VAC 190A

120VAC 250A

312VAC 95A

270VDC 140A

28VDC 250A

50/60Hz AC

400Hz AC (90kVA)

DC

3 phase 208VAC 200A

3-phase 208VAC 30A*

3-phase 208VAC 200A

3-phase 208VAC 30A

600VDC 17A

270VDC 140 A

28VDC 1000A

Programmable Power Supplies

Steady State Power Supplies

*30A are available at RF chambers, contact Elite for 200A service.