ecolor cove ec powercore - color kinetics€¦ · 4 ecolor cove ec powercore product guide product...

8
eColor Cove EC Powercore Cost-effective linear interior LED cove and accent fixture with solid color light

Upload: others

Post on 21-May-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: eColor Cove EC Powercore - Color Kinetics€¦ · 4 eColor Cove EC Powercore Product Guide Product Selection To order eColor Cove EC Powercore, select a fixture color, a line voltage

eColor Cove EC PowercoreCost-effective linear interior LED cove and accent fixture with solid color light

Page 2: eColor Cove EC Powercore - Color Kinetics€¦ · 4 eColor Cove EC Powercore Product Guide Product Selection To order eColor Cove EC Powercore, select a fixture color, a line voltage

eColor Cove EC Powercore Product Guide2

eColor Cove EC Powercore Cost-effective linear interior LED cove and accent fixture with solid color light

• IntegratespatentedPowercoretechnology—Powercorerapidly,efficiently,andaccuratelycontrolspoweroutputtofixturesdirectlyfromlinevoltage,eliminatingtheneedforanexternalpowersupply.Contractor-friendlyinstallationdramaticallysimplifiesinstallationandlowerstotalsystemcost.

• Supportformultiplevoltages—eColorCoveECPowercoreacceptspowerinputof100,120,or220–240VAC,allowingconsistentinstallationinanylocationaroundtheworld.

• Smoothdimmingcapability—PatentedDIMandtechnologyofferssmoothdimmingcapabilitywithselectedcommerciallyavailablereverse-phaseELV-typedimmers.

• Easyinstallation—Powercoredeliverslinevoltagedirectlytothefixtures,simplifyinginstallationbyeliminatingtheneedforexternalpowersuppliesandallowinglongproductruns.Easy-to-install4ft(1.2m)mountingtracksallowquickprojectsetupinlinearapplications.

• Flexiblemountingandpositioning—Withend-to-endlockingpowerconnectorsthatcanmake180ºturns,eColorCoveECPowercorefixturesareeasytopositionineventhemostchallengingmountingcircumstances.Fixturesrotatein10°incrementsthroughafull180°forpreciseaimingandbeammixing.Optionalmountingtrackssupportverticalandoverheadpositioning.1ft(305mm)and5ft(1.5m)jumpercablescanaddextraspacebetweenfixtures.

eColorCoveECPowercoreisadimmable,linearLEDfixturethatprovidesanaffordable,energy-efficientlightinginapplicationsrequiringsaturatedblueoramberlight.Withitslowprofile,rotatinghousing,andend-to-endlockingpowerconnectors,eColorCoveECPowercoreistheperfectchoiceforawiderangeofinteriorretail,exhibit,hospitality,andarchitecturalsettings.

Compact and flexibleeColorCoveECPowercorelow-profilefixturesfitinnarrowalcoves,displaycases,lightboxes,andothertightspaceswherelightsourcesrequiringballasts,externalpowersupplies,andotherauxiliaryequipmentcannot.

Page 3: eColor Cove EC Powercore - Color Kinetics€¦ · 4 eColor Cove EC Powercore Product Guide Product Selection To order eColor Cove EC Powercore, select a fixture color, a line voltage

eColor Cove EC Powercore Product Guide 3

SpecificationsDuetocontinuousimprovementsandinnovations,specificationsmaychangewithoutnotice.

110º

10º

110º

180º

5.6 in(142 mm)

5.1 in(130 mm)

6 in(152 mm)

7.6 in(193 mm)

12 in(305 mm)

8.1 in(206 mm)

1.4 in(35 mm)

1.2 in(30 mm)

1 in(25 mm)

120V 120V

120V120V

E To calculate the number of fixtures your specific installation can support, download the Configuration Calculator from www.philipscolorkinetics.com/support/install_tool/

* Refertowww.philipscolorkinetics.com/support/appnotes/forspecificdetails.†Fixturesinstalledend-to-end,20Acircuit,standard10ft(3.1m)LeaderCable.Thesefigures,providedasaguideline,areaccurateforthisconfigurationonly.Changingtheconfigurationcanaffectthefixturerunlengths.

.875 in(22.2 mm)

1.75 in(44.5 mm)

1.25 in(31.8 mm)

4.375 in(111.1 mm)1.75 in

(44.5 mm)

UL/cULWiringCompartment

E For help estimating the light output and distribution of eColor lighting fixtures, please contact Philips Color Kinetics Applications Engineering Services at [email protected].

Item Specification 6in(152mm) 12in(305mm)

Output BeamAngle 110°x110°

Electrical

InputVoltage 120VAC,50/60Hz 100/120/220–240VAC,50/60Hz

PowerConsumption 1.5Wmaximumatfulloutput,steadystate

3.0Wmaximumatfulloutput,steadystate

PowerFactor .96@120VAC

Control Dimming Compatiblewithselectedcommerciallyavailablereverse-phase(ELV-type)dimmers*

Physical

Dimensions(Height x Width x Depth)

1.25x6x1.4in(32x152x35mm)

1.25x12x1.4in(32x305x35mm)

Weight 0.19lbs(85g) 0.31lbs(142g)

Housing Injection-moldedplastic,dark-grayfinish

Lens Clearpolycarbonate

FixtureConnections Integralmale/femaleconnectors

TemperatureRanges-4°–122°F (-20°–50°C)Operating-4°–122°F (-20°–50°C)Startup-40°–176°F(-40°–80°C)Storage

Humidity 0–95%,non-condensing

MaximumFixtureRunLengths† 191@120VAC

122@100VAC134@120VAC191@240VAC

CertificationandSafety

Certification UL/cUL,FCCClassB,CE,CCC,C-Tick,SAA

Environment DryLocation,IP20

EnergyEfficiency CaliforniaTitle24Compliant

Page 4: eColor Cove EC Powercore - Color Kinetics€¦ · 4 eColor Cove EC Powercore Product Guide Product Selection To order eColor Cove EC Powercore, select a fixture color, a line voltage

eColor Cove EC Powercore Product Guide4

Product Selection ToordereColorCoveECPowercore,selectafixturecolor,alinevoltageconnectionoption,afixturelength(120VAConly),andanyextraoptionsyoumightneed.

Item Type Size ItemNumber Philips12NC

eColorCoveECPowercore,100VAC

Blue 12in(305mm) 223-000004-70 910503701081

Amber 12in(305mm) 223-000004-71 910503701082

eColorCoveECPowercore,120VAC

Blue6in(152mm) 223-000005-62 910503701085

12in(305mm) 223-000004-62 910503701073

Amber6in(152mm) 223-000005-63 910503701086

12in(305mm) 223-000004-63 910503701074 eColorCoveECPowercorefixtures

eColorCoveECPowercore,220–240VAC/CE

Blue 12in(305mm) 223-000004-66 910503701077

Amber 12in(305mm) 223-000004-67 910503701078

eColorCoveECPowercore,220–240VAC/CCC

Blue 12in(305mm) 223-000004-72 910503701670

Amber 12in(305mm) 223-000004-73 910503701671

LeaderCablewithterminatorandstrainrelief

UL/cUL 10ft(3m) 108-000032-00 910503700586Forconnectiontostandardjunctionbox

CE 10ft(3m) 108-000032-02 910403325901

WiringCompartmentwithterminator UL/cUL 120-000076-00 910503700597

Canbeusedfordirectconnectiontoconduit

LeaderCablewithplug UL/cUL 8ft(2.4m) 108-000032-03 910503700394 Forportableinstallations

JumperCable

UL/cUL1ft(305mm) 108-000033-00 910403600101

Dependingontheinstallation’sdesign,youmayneedjumpercablestoaddspacebetweenfixtures

5ft(1.5m) 108-000033-01 910403600102

CE1ft(305mm) 108-000033-02 910403326001

5ft(1.5m) 108-000033-03 910403326101

MountingTrackMinimum order quantity 25 4ft(1219mm) 523-000006-01 910503700452 Optionalmountingtrack

ensuresstraightrunsoffixtures

UseItemNumberwhenorderinginNorthAmerica.

6 in (152 mm)

12 in (305mm)

Choose length (120 VAC only)

Choose fixture color

Red Green

Choose line voltage connection option

Leader cable

Permanent Installations

Portable Installations

Leader cable

Wiring compartment, UL / cUL

Choose optional accessories

5 ft (1.5 m) Jumper cable

1 ft (305 mm) Jumper cable

Mounting track

4

Blue Amber

Fixtures and Accessories

Page 5: eColor Cove EC Powercore - Color Kinetics€¦ · 4 eColor Cove EC Powercore Product Guide Product Selection To order eColor Cove EC Powercore, select a fixture color, a line voltage

eColor Cove EC Powercore Product Guide 5

InstallationeColorCoveECPowercoreoffershigh-output,energy-efficientindoorwhiteandsolidcoloralcovelightingwithPowercoretechnology.Powercore,whichdeliverslinevoltagedirectlytothefixture,easesinstallationbyeliminatingtheneedforexternalpowersuppliesorspecialwiring.

Owner / User ResponsibilitiesItistheresponsibilityofthecontractor,installer,purchaser,owner,andusertoinstall,maintain,andoperateeColorCoveECPowercorefixturesinsuchamannerastocomplywithallapplicablecodes,stateandlocallaws,ordinances,andregulations.Consultwiththeappropriateelectricalinspectortoensurecompliance.

Create a Layout Plan Regardlessofthesizeandcomplexityofyourinstallation,thetimeyouspendplanningcanhelpminimizeinstallationandconfigurationissueslater.Keepthesesuggestionsinmindasyouplanyourinstallation:

• Onanarchitecturaldiagramorotherdiagramthatshowsthephysicallayoutoftheinstallation,createalayoutmapthatspecifiestheappropriatelocationofthelightfixturesinrelationtoeachother,andtoanydimmerswitches,wallswitches,andlinepowersources.Identifyanyobstaclesorphysicalfeaturesrequiringflexiblejumpercablesbetweenfixtures.

• Usingthefixture’spowerconsumptionandefficiencyratings,thelightingdesignerorarchitectshouldcalculatethecovedimensionstoensurethatoperatingtemperaturesremainwithinsafelevels.Thedesignerorarchitectshouldalsodeterminethecove’sfasciadesignandfixturesetbackbasedonthecovedimensionsandroomwidth.Westronglyrecommendcreatingdimensionalmodelsandmockupspriortoinstallation.

• eColorCoveECPowercorefixturesareinstalledinseries.Thein-lineconnectorsallowend-to-endfixtureconnectionsforthebestvisualeffects.Wheninstallingfixturesend-to-end,allowaminimumdistanceof.125in(3mm)betweenfixtures,andamaximumdistanceof.625in(16mm).Formorespacingbetweenfixtures,usethe1ft(305mm)or5ft(1.5m)jumpercables.

• YoucaninstallarunofeColorCoveECPowercorefixturesusingthe10ft(3m)LeaderCablewithflyingleads.Thisoptionispreferablewhenconnectingtoathird-partyjunctionbox,orwhenretrofittinganexistingincandescentorfluorescentcovelightinginstallation.

• InNorthAmerica,youcanusetheWiringCompartmentwhenyouwanttorunbranchconduitallthewaytothefirstfixtureinaseries,orwherelocalcodesrequireit.Youcanalsocreateaportableinstallationbyusingthe8ft(2.4m)LeaderCablewithplug.

• Iffixturesareinstalledend-to-endona20Acircuitusingthestandard10ft(3m)LeaderCable,eachruncanaccommodateup19112in(305mm)fixtures.Usingtheoptionaljumpercablescandecreasethenumberoffixturesthatyoucanconnectinasinglerun.

Install Wall and Dimmer Switches (Optional)eColorCoveECPowercorefixturescanbecontrolledeitherwithastandardwallswitch(on/off)oracompatible,commerciallyavailablereverse-phaseELV-typedimmer.

ForalistofcompatibleELVdimmers,andfordetailsonselectingtheappropriatedimmerforyourlightinginstallation,visitwww.philipscolorkinetics.com/support/appnotes,orconsultApplicationsEngineeringservicesatsupport@colorkinetics.com.

Distancebetweenfixtures

EasyturnsEnd-to-endlockingpowerconnectorscanmaketurnsofupto180ºwithoutjumpercables.

5 in(128 mm)

4.5 in(114 mm)

.125 in(3 mm)

.625 in(16 mm)

120V120V

120V120V

IncludedintheboxeColorCoveECPowercorefixtureInstallationInstructions

E Refer to the eW / eColor EC Cove Powercore Installation Instructions for specific warning and caution statements.

E To calculate the number of fixtures your specific installation can support, download the Configuration Calculator from www.philipscolorkinetics.com/support/install_tool/, or consult Philips Color Kinetics Application Engineering Services at [email protected].

E Refer to the installation instructions included with the wall or dimmer switch for installation and wiring information.

Page 6: eColor Cove EC Powercore - Color Kinetics€¦ · 4 eColor Cove EC Powercore Product Guide Product Selection To order eColor Cove EC Powercore, select a fixture color, a line voltage

eColor Cove EC Powercore Product Guide6

Prepare for the Installation1. Verifythatallsupportingequipment(switches,linepowersources)isinplace.

2. Ifyourinstallationcallsforjumpercablestoaddspacebetweenfixtures,makesuretheyareavailable.

3. Ensurethatalladditionalparts(optionalmountingtracks,mountinghardware,terminators)andtoolsareavailable.

Install the FixturesYoucanmounteColorCoveECPowercorefixturesdirectlytoawall,ceiling,cabinet,orothersecuresurface.YoucaninstallseveraleColorCoveECPowercorefixturesinoptional4ft(1.2m)lengthsofmountingtracktoensureastraightrun.

Install Mounting Tracks (Optional)1. Field-cutthemountingtrackstothedesiredlengthwithahacksawortinsnips.

2. Installthemountingtracksusinghardwaresuitableforthemountingsurface.

Toensureproperfixturefit,hardwaremustnotextendabovethetrackstandoffsafterinstallation.Therecommendedmaximumspacingbetweenscrewsis12in(305mm).

Mount and Connect the FixturesMakesurethepowerisOFFbeforemountingandconnectingeWCoveECPowercorefixtures.

1. RotateaneWCoveECPowercorefixtureasnecessarytoprovideunobstructedaccesstothemountingholes.

2. Positionthefirstfixtureinaseries.

Ifusingmountingtracksonahorizontalsurface,snapthefixtureintothetrack.

Ifusingmountingtracksonverticaloroverheadsurfaces,orifnotusingmountingtracks,attachthefixturewithfour#6(3.5mm)mountingscrews(notincluded)suitableforthemountingsurface.

EnsurethatthemaleconnectorisinpositiontoreceivepowerfromthefemaleconnectorontheLeaderCableorWiringCompartment.

E You can use the fixture base as a template when pre-drilled pilot holes are required. Hold the fixture in place and mark the four screw holes.

OK

Page 7: eColor Cove EC Powercore - Color Kinetics€¦ · 4 eColor Cove EC Powercore Product Guide Product Selection To order eColor Cove EC Powercore, select a fixture color, a line voltage

eColor Cove EC Powercore Product Guide 7

3. Positionthenextfixtureintheseries,matchingthemaleconnectorendtothefemaleconnectorofthepreviouslymountedfixture.Attachthefixturetothesurfaceorsnapitintothetrack.

4. Continuemountingthefixtures,makingpowerconnectionsasyougo,untilalllightsintheseriesaremounted.

5.Inserttheprovidedterminatorintothelastfixtureintheseries.

Make Power Connections

Torunpowerorconduittothefirstfixtureinaseries(permanent, UL / cUL installations):

1. RemovethecoverfromtheeWCovePowercoreWiringCompartment.

2. Usingwirenuts,connectground,neutral,andlineinsidetheWiringCompartmenthousing,thenreplacethecover.

3. ConnecttheeWCovePowercoreWiringCompartmenttothefirstfixtureintheseries.

CLICK!

Terminator

End-to-End1ft.or5ftJumperCable

.875 in(22.2 mm)

1.75 in(44.5 mm)

1.25 in(31.8 mm)

4.375 in(111.1 mm)1.75 in

(44.5 mm)

UL/cULWiringCompartment

Page 8: eColor Cove EC Powercore - Color Kinetics€¦ · 4 eColor Cove EC Powercore Product Guide Product Selection To order eColor Cove EC Powercore, select a fixture color, a line voltage

Toconnectthefirstfixtureinaseriestoathird-partyjunctionboxusing the 10 ft (3 m) Leader Cable (permanent installation):

1. Removethecoverofthethird-partyjunctionbox.

2. Connectground,neutral,andlineinsidethejunctionboxhousing,thenreplacethejunctionboxcover.

3. Connectthe10ft(3m)LeaderCabletothefirstfixtureintheseries.

For portable installations (UL / cUL):

1. Plugthe8ft(2.4m)LeaderCableintoasuitableswitchedoutlet.

2. ConnecttheLeaderCabletothefirstfixtureintheseries.

For CE installations:

1. ConnecttheLeaderCabletoaterminalblock.TheterminalblockmustconformtoEN60998-2-1orEN60998-2-2,rated220–240VAC.

2. Connectground,neutral,andlinetoapowersource.

3. ConnecttheLeaderCabletothefirstfixtureintheseries.

Aim the FixturesMakesurethepowerisONbeforeaimingfixtures.

Aimthefixturesbyrotatingeachfixturetothecorrectangle.Therearedetentsevery10°inthebracketthatholdthefixtureinposition.

.375 in(9.5 mm)

.675 in(15.9 mm)

1.13 in(28.6 mm)

1.25 in(31.8 mm)

.375 in(9.5 mm)

.675 in(15.9 mm)

1.13 in(28.6 mm)

1.25 in(31.8 mm)

LeaderCableconnectordimensions

110º

10º

110º

180º

Philips Color Kinetics3 Burlington Woods DriveBurlington, Massachusetts 01803 USATel 888.385.5742Tel 617.423.9999Fax 617.423.9998www.philipscolorkinetics.com

Copyright © 2011 - 2012 Philips Solid-State Lighting Solutions, Inc. All rights reserved. Chromacore, Chromasic, CK, the CK logo, Color Kinetics, the Color Kinetics logo, ColorBlast, ColorBlaze, ColorBurst, ColorGraze, ColorPlay, ColorReach, iW Reach, eW Reach, eW Fuse, DIMand, EssentialWhite, eW, iColor, iColor Cove, IntelliWhite, iW, iPlayer, Optibin, and Powercore are either registered trademarks or trademarks of Philips Solid-State Lighting Solutions, Inc. in the United States and / or other countries. All other brand or product names are trademarks or registered trademarks of their respective owners. Due to continuous improvements and innovations, specifications may change without notice. DAS-000101-00 R00 05-12

E Do not look directly into beam when aiming fixtures.