Early Detection Systems Ltd

Gas Leak DetectionTo suit all needs

Page 2: Early Detection Systems Ltd - Metrostar Techmetrostartech.com/images/EDS/EDS_Shield_Gen_Lit.pdfEarly Detection Systems Ltd Gas Leak Detection ... A brief description of each is listed

Conventional Gas Detection Modules

The modules available are:

1. Systems module – Two types are available to suit most applications.

i. Standard S12 for larger panels.

ii. Medium Duty S14 when no sprinklers are used

2. Gas detection module, single channel – occupies one slot.

3. Gas detection module, twin channel – occupies one slot.

4. Tank Monitoring module—occupies one slot and monitors the Gas Panel asso-

ciated with one Tank. Up to eight Tank modules may be fitted into one system.

5. Mimic modules. Various to suit application.

6. Various Gas Sensors for both Flammable and Carbon Monoxide Gases.

Two Zone Gas Module

The Two Zone Gas Module monitors two separate circuits of gasdetectors. All voltages gains etc are individually set to each chan-nel.

It Monitors and controls:

1. Two Gas detection Sensors.

2. Indicates % Lower Explosive Limit—LEL separately for eachchannel in individual 7 segment LED displays.

3. Push button provided to allow isolation of the zone duringmaintenance.

4. A test facility is provided to show the alarm levels which arepreset. These levels may be adjusted but are factory set at 15and 30% LEL.

• • • • • • • • • •

Single Zone Gas Module

The Single Zone Gas Module is simple a module equipped with half thecircuitry of the two zone gas module.

Page 3: Early Detection Systems Ltd - Metrostar Techmetrostartech.com/images/EDS/EDS_Shield_Gen_Lit.pdfEarly Detection Systems Ltd Gas Leak Detection ... A brief description of each is listed

Modules

Early Detection Systems Ltd. has a wide range of equipment marketed under the trade name ofEDS-Shield.

A brief description of each is listed below to assist customers in selecting the products best suitedto the application. All products are designed and built by our own engineers in the UK. EDS panelsgive the most cost effective solution to the all building requirements.

Modules include:

S12 Systems Module

The S12 Systems Module is suitable for smaller gas detec-tion systems with up to 6 gas ones. It Monitors and controls:

1. The connected gas modules for both alarm and fault.

2. The both the Mains and Battery supply is monitored.

3. Battery charging.

4. Sprinkler System is both monitored and controlled.

The sprinklers may be activated by on module switches.

5. The Gas supply is monitored for correct pressure andmay be turned off by switch activation. Both sprinkler andgas solenoids are reversed by a sensor detecting gas.

• • • • • • • • • •

Tank Module

The Tank Module is usually used on larger systems with more than one tank.

It Monitors and controls:

1. One Tank Gas detection Sensor.

2. Gas Pressure

3. Gas ON—OFF Manual Control

4. Both Gas % LEL and Tank Fill % Level is displayed on Seven segment displays.

• • • • • • • • • •

Page 4: Early Detection Systems Ltd - Metrostar Techmetrostartech.com/images/EDS/EDS_Shield_Gen_Lit.pdfEarly Detection Systems Ltd Gas Leak Detection ... A brief description of each is listed

Early Detection Systems Ltd

Sigo Conventional and Addressable Control Panels

40 characters of text to each device

120 characters of system information

Programmable Logic

Network operation

Sounder Silence

Reset

Gas Supply on/off

Sprinklers on/off

LED indication for:

Power

Supply Faults

Alarm Level 1 & 2

External Alarm 1 & 2

Switches Enabled

The Panel interfaces with 1 to 48 conventional sensors and or Addressable sensors to a total of 127devices.

These detectors can be either conventional type OR analogue addressable type up to a total of 127zones.

The conventional sensors are connected back to the panel with a 3 core cable to each. Addressablesensors are with a 4 wire that carries both power and data to and from the sensors.

Three Addressable lines each with a maximum of 48 sensors / devices may be connected.

Optional devices such as Addressable Solenoid and Relay panels may be addressed and controlled bythe programmable logic.

PANEL

Sounder and Beacon Drive are provided as standard for general building alarm along with controls forsprinkler monitoring and gas supply control.

Outputs provided are:Gas Solenoid and Sprinkler Solenoid, both monitored for solenoid connectionSounderBeaconFire Panel in.Fire Panel OutAlarm 1, 2 and 3 including Fault relay contacts.RS485 network connection for BMS connection.

Page 5: Early Detection Systems Ltd - Metrostar Techmetrostartech.com/images/EDS/EDS_Shield_Gen_Lit.pdfEarly Detection Systems Ltd Gas Leak Detection ... A brief description of each is listed

Sigo Conventional and or Addressable

LCD Display 40 characters of text message per sensor.120 characters of status conditions.

Enclosure Robust steel enclosure painted Ash Grey, wall mounted.

Zones Conventional 3 wire sensors. Up to 36 zones per panel.Addressable 4 wire sensors. Up to 244 zones per panel

Arrangement Conventional AND addressable zones may be interlaced on the Panel by simply program-ming on site using standard Sigo PC

Programme supplied with the Panel.

Logic The operation of inputs can cause outputs to operate to suit theSite requirements. See sample Program supplied in standardExcel Format.

Outputs Relay modules. Any slot may be fitted with a Relay module rated at1A 60V DC.Solenoid modules. Any slot may be fitted with a Solenoid driverModule for 24V DC 18W gas relays. Solenoids can be normallyenergised or normally energised.

Front Panel Indications:PowerGeneral FaultGas Tank Level HighGas Tank Level LowGas Solenoid OnGas Solenoid OffSprinkler Solenoid OnSprinkler Solenoid OffCommon Alarm 1Common Alarm 2External Alarm 1External Alarm 2

Switch Buttons: Panel Accept, Evacuate, Silence, Reset,Gas Solenoid on/off, Sprinkler Solenoid on/off

Display Buttons:Up, Down, Left, Right, Menu and Enter

Logging History is available on the LCD Display

Power Mains AC 220/230 50/60Hz 110/120 available as option.Battery Internal battery 7Ah

Approvals EMC Meets EN6101-1 EN50270

Humidity 0—96% non-condensing

Ambient Temperature -10 - +40°C

Alarm Fault indication LED display for Alarm LevelsLCD display for Alarm LevelsIncluding Location information.

Priority Display The LCD display defaults to a priority display as follows:Second Stage AlarmsFirst Stage AlarmsFaultsAnalogue values in descending order.

This allows any important conditions to be understood immediately.Thereby saving valuable time.