e. jasmine avenue · 9as shown podocarpus macrophylla podocarpus 5 gal. 54" ht....

8
1. CONTRACTOR IS REQUIRED TO PERFORM MINOR CLEARING AND GRUBBING SERVICES FOR ENTIRE SITE PRIOR TO INSTALLING P THIS INCLUDES BUT IS NOT LIMITED TO REMOVAL OF WEEDS, TRASH, AND SCRUB LIKE MATERIAL. IT IS POSSIBLE THIS MAY IN GRADING SERVICES TO ASSURE NO HOLES OR TRIPPING HAZARDS ARE PRESENT. CONTRACTOR SHOULD INCLUDE THIS IN BID P 2. CONTRACTOR SHALL NOTIFY CARDNO IMMEDIATELY IF EXISTING TREES SHOWN ON THIS PLAN AS REMAINING DO NOT EXIST. A MATERIAL MAY BE REQUIRED TO ACCOUNT FOR MISSING TREES. 3. ALL EXISTING PALMS SLATED TO REMAIN SHALL BE CLEANED UP AND DEBOOTED UP TO A REASONABLE HEIGHT APPROPRIATE TO HEIGHT. ALL VINES ON EXISTING TREES SHALL BE REMOVED. 4. AREAS OF THE LAWN MAY CONTAIN CATCH BASINS AND AREA DRAINS. CONTRACTOR SHALL USE BEST JUDGEMENT TO FINE GR CATCH BASINS AND OTHER APPURTENANCES TO MINIMIZE EROSION AND MAINTAIN AESTHETIC VALUE. TREES LOCATED IN DRA SHALL BE FIELD ADJUSTED TO PLACE TREES OUTSIDE OF DRAINAGE WAY. CONTACT LANDSCAPE ARCHITECT WITH ANY DISCREP 5. CONTRACTOR TO FLAG ALL PROPERTY LINES, EASEMENT LINES, ETC. TO INSTALL PLANTING AND IRRIGATION AS PER PLANS. CO CONTACT OWNER AND LANDSCAPE ARCHITECT PRIOR TO INSTALLATION IF ANY LOCATIONS ARE UNCLEAR GENERAL LANDSCAPE NOTES MISCELLANEOUS ITEM SIZE COMMENTS GROUNDCOVERS/SOD ITEM SIZE QUANTITY SPACING LANDSCAPE PLANT MATERIAL SCHEDULE TREES ITEM SIZE QUANTITY SPACING SHRUBS & ACCENTS ITEM SIZE QUANTITY SPACING SYMBOL EXISTING TREES TO REMAIN, EVERGREEN & DECIDUOUS CONTRACTOR TO PROTECT WITHIN DRIP LINES SEE TREE PROTECTION & DEMOLITION PLANS TAXODIUM DISTICHUM BALD CYPRESS 1.5" CAL. 6' HT. 7 AS SHOWN QUERCUS VIRGINIANA LIVE OAK 1.5" CAL. 6' HT. 10 AS SHOWN ULMUS AMERICANA V. FLORIDANA FLORIDA ELM 1.5" CAL. 6' HT. 9 AS SHOWN PODOCARPUS MACROPHYLLA PODOCARPUS 5 GAL. 54" HT. 190 5'-0" O.C. MATURE: 6-7' HT. / 5' WD. LIRIOPE MUSCARI BIG BLUE LILY TURF 1 GAL. 196 1'-6" O.C. STENOTAPHRUM SECUNDATUM 'SAPPHIRE' ST. AUGUSTINE SAPPHIRE SOD 94,000 SF LANDSCAPE ORDINANCE REQUIREMENTS: MINIMUM PLANTING REQUIREMENT SITE AREA: 125,670 SF (DOES NOT INCLUDE WETLAND AREA OR DETENTION POND) MINIMUM REQUIRED TREES: 71 TREES (8 FOR FIRST 15,000SF AND 1 FOR EVERY 2,000SF IN EXCESS OF THAT) EXISTING TREES RETAINED: 43 TREES PROPOSED TREES: 44 TREES TOTAL TREES: 87 TREES VUA REQUIREMENTS PROPOSED PARKING SPACES: 43 SPACES REQUIRED INTERIOR LANDSCAPE AREA: 800 SF PROPOSED INTERIOR LANDSCAPE AREA: 2,245 SF REQUIRED TREES: 8 TREES PROPOSED TREES: 8 TREES (6 PROPOSED AND 2 EXISTING) DETENTION POND REQUIREMENTS TOTAL POND AREA FROM T.O.B.: 7,030 SF 20% OF TOTAL AREA: 1,406 SF REQUIRED TREES: 5 (1 PER 300 SF OF THE CALCULATED 20% AREA) PROPOSED TREES: 5 EAST BUFFER REQUIREMENTS WIDTH: 8 FT LENGTH: 330 LF REQUIRED TREES: 13 TREES (1 PER 25 LF PROPOSED TREES: 13 TREES REQUIRED SHRUBS: 1 HEDGE ROW PROPOSED SHRUBS: 1 HEDGE ROW NUMBER INDICATED ON HATCH THROUGHOUT DRAWING REFLECTS THE NUMBER OF PLANTS IN THAT PARTICULAR AREA MULCH: ALL SHRUB BEDS SHALL CONTAIN A 3" LAYER OF SHREDDED CYPRESS MULCH. CONTRACTOR TO PLACE MIN. 4' DIAMETER CYPRESS MULCH CIRCLE AROUND ALL TREES IN SOD (TYP COMMENTS ILEX VOMITORIA YAUPON HOLLY 5 GAL. 54" HT. 14 5'-0" O.C. MATURE: 6-7' HT. / 5' WD. ACACIA FARNESIANA SWEET ACACIA 1.5" CAL. 6' HT. 15 AS SHOWN MAGNOLIA GRANDIFLORA SOUTHERN MAGNOLIA 1.5" CAL. 6' HT. 3 AS SHOWN ILEX VOMITORIA 'SCHILLINGS' SHILLINGS HOLLY 3 GAL. 18" GAL. 41 3'-0" O.C. 12 WATER METER 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 5 4 2 1 6 5 4 2 1 6 5 4 2 6 5 4 2 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 3 3 6 5 4 3 2 6 5 4 6 5 4 3 2 1 6 5 4 3 2 1 4 3 2 1 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 5 4 3 2 1 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 6 3 2 1 3 2 1 3 2 1 3 2 1 6 5 4 5 4 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 6 5 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 3 2 1 3 5 4 3 3 3 3 3 3 1 3 2 1 6 5 4 3 2 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 2 1 1 1 3 2 1 3 2 1 WATER METER 2 3 3 4 6 2 1 E. TARPON AVENUE E. JASMINE AVENUE EXISTING CYCADIA CEMETERY EXISTING SIDEWALK E. JASMINE AVENUE EXISTING SOD TO REMAIN WETLAND EXISTING FIBER OPTIC PULL BOX TO REMAIN EXISTING TRAFFIC CONTROL UTILITY CABINETS AND CONCRETE PADS TO REMAIN PROPOSED ORNMANETAL FENCE AND COLUMNS (TYP.). SEE CIVIL PLANS FOR MORE INFORMATION EXISTING SIDEWALK PROPOSED SIDEWALK PROPOSED ENTRY MONUMENT. SEE CIVIL PLANS FOR MORE INFORMATION EXISTING UTILITY PEDESTAL TO REMAIN SOD LIMIT LINE (TYP) 8 10 4 6 8 8 8 12 14 16 18 MINOR CLEARING AND PRUNING LIMITS. SEE NOTE ABOVE ONE FOOT OF MULCH TO BE INSTALLED IN FRONT AND BEHIND FENCE (TYP. OF ALL) EXISTING POWER LINE POLE 10 15 6 7 8 9 9 9 11 11 11 12 12 13 14 16 17 18 5 5 10 15 6 6 7 7 8 8 9 9 11 12 13 14 STORMWATER POND SEE CIVIL PLANS FOR MORE INFORMATION 20' BUILDING SETBACK 15' WETLAND BUFFER 20' BUILDING SETBACK PROPOSED CHAIN LINK FENCE (TYP.). SEE CIVIL PLANS FOR MORE INFORMATION MINOR CLEARING AND PRUNING NOTE: CONTRACTOR WILL BE REQUIRED TO PERFORM MINOR CLEARING AND PRUNING FOR THE TREE SAVE AREA BETWEEN THE SOD EDGE AND WETLAND AREA. THIS WILL INCLUDE REMOVAL OF GENERAL DEBRIS, INCLUDING TREES 2" CAL. OR LESS, HANGING LIMBS, DEAD LIMBS ON TREES AND ON THE GROUND. PINE NEEDLES WILL BE REQUIRED WITHIN THE AFOREMENTIONED AREA. CYCADIA CEMETERY EAST (PHASE I) SEPTEMBER 2019 CITY OF TARPON SPRINGS 00287-011.01 ANDREW HILL, PLA LA6667073 PROJECT NO: DATE: SHEET NO: LIC. NO.: DATE BY DATE DESCRIPTION NO. DESIGNED DRAWN Q.C. APPROVED CJC, JLG CJC, JLG CJC LA 6667073 STATE OF A N D R E W D . H I L L CLEARWATER 380 PARK PLACE BLVD , STE 300 , CLEARWATER , FL 33759 TEL : (727) 531 - 3505 FAX : (727) 431 - 1777 www . cardno . com Cer t i f i ca t e o f Au t hor i za t i on No . 29915 09-20-19 0 0 20' 40' MATCHLINE-SEE SHEET L 1.01 PLANTING PLAN L1.00 NOTE: ALL SOD TO BE PLACED WITHIN POND SHALL BE HARVESTED FROM NON-MUCK GROWN FARMS. MATCHLINE-SEE SHEET L 1.01

Upload: others

Post on 29-Jul-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: E. JASMINE AVENUE · 9as shown podocarpus macrophylla podocarpus 5 gal. 54" ht. 1905'-0" o.c. mature: 6-7' ht. / 5' wd. liriope muscari big blue lily turf 1 gal.1961'-6" o.c. stenotaphrum

1. CONTRACTOR IS REQUIRED TO PERFORM MINOR CLEARING AND GRUBBING SERVICES FOR ENTIRE SITE PRIOR TO INSTALLING PLANT MATERIAL.

THIS INCLUDES BUT IS NOT LIMITED TO REMOVAL OF WEEDS, TRASH, AND SCRUB LIKE MATERIAL. IT IS POSSIBLE THIS MAY INCLUDE SOME FINE

GRADING SERVICES TO ASSURE NO HOLES OR TRIPPING HAZARDS ARE PRESENT. CONTRACTOR SHOULD INCLUDE THIS IN BID PRICE.

2. CONTRACTOR SHALL NOTIFY CARDNO IMMEDIATELY IF EXISTING TREES SHOWN ON THIS PLAN AS REMAINING DO NOT EXIST. ADDITIONAL PLANT

MATERIAL MAY BE REQUIRED TO ACCOUNT FOR MISSING TREES.

3. ALL EXISTING PALMS SLATED TO REMAIN SHALL BE CLEANED UP AND DEBOOTED UP TO A REASONABLE HEIGHT APPROPRIATE TO OVERALL

HEIGHT. ALL VINES ON EXISTING TREES SHALL BE REMOVED.

4. AREAS OF THE LAWN MAY CONTAIN CATCH BASINS AND AREA DRAINS. CONTRACTOR SHALL USE BEST JUDGEMENT TO FINE GRADE AROUND

CATCH BASINS AND OTHER APPURTENANCES TO MINIMIZE EROSION AND MAINTAIN AESTHETIC VALUE. TREES LOCATED IN DRAINAGE WAYS

SHALL BE FIELD ADJUSTED TO PLACE TREES OUTSIDE OF DRAINAGE WAY. CONTACT LANDSCAPE ARCHITECT WITH ANY DISCREPANCIES.

5. CONTRACTOR TO FLAG ALL PROPERTY LINES, EASEMENT LINES, ETC. TO INSTALL PLANTING AND IRRIGATION AS PER PLANS. CONTRACTOR TO

CONTACT OWNER AND LANDSCAPE ARCHITECT PRIOR TO INSTALLATION IF ANY LOCATIONS ARE UNCLEAR

GENERAL LANDSCAPE NOTES

MISCELLANEOUSITEM SIZE COMMENTS

GROUNDCOVERS/SODITEM SIZE QUANTITY SPACING

LANDSCAPE PLANT MATERIAL SCHEDULETREESITEM SIZE QUANTITY SPACING

SHRUBS & ACCENTSITEM SIZE QUANTITY SPACING

SYMBOL

EXISTING TREES TO REMAIN, EVERGREEN & DECIDUOUS

CONTRACTOR TO PROTECT WITHIN DRIP LINES

SEE TREE PROTECTION

& DEMOLITION PLANS

TAXODIUM DISTICHUM

BALD CYPRESS

1.5" CAL.

6' HT.

7 AS SHOWN

QUERCUS VIRGINIANA

LIVE OAK

1.5" CAL.

6' HT.

10 AS SHOWN

ULMUS AMERICANA V. FLORIDANA

FLORIDA ELM

1.5" CAL.

6' HT.

9 AS SHOWN

PODOCARPUS MACROPHYLLA

PODOCARPUS

5 GAL.

54" HT.

190 5'-0" O.C.

MATURE: 6-7' HT. / 5' WD.

LIRIOPE MUSCARI

BIG BLUE LILY TURF

1 GAL. 196 1'-6" O.C.

STENOTAPHRUM SECUNDATUM 'SAPPHIRE'

ST. AUGUSTINE SAPPHIRE

SOD94,000 SF

LANDSCAPE ORDINANCE REQUIREMENTS:

MINIMUM PLANTING REQUIREMENT

SITE AREA: 125,670 SF (DOES NOT INCLUDE

WETLAND AREA OR DETENTION POND)

MINIMUM REQUIRED TREES: 71 TREES (8 FOR FIRST 15,000SF

AND 1 FOR EVERY 2,000SF IN EXCESS

OF THAT)

EXISTING TREES RETAINED: 43 TREES

PROPOSED TREES: 44 TREES

TOTAL TREES: 87 TREES

VUA REQUIREMENTS

PROPOSED PARKING SPACES: 43 SPACES

REQUIRED INTERIOR LANDSCAPE AREA:800 SF

PROPOSED INTERIOR LANDSCAPE AREA:2,245 SF

REQUIRED TREES:8 TREES

PROPOSED TREES: 8 TREES (6 PROPOSED AND 2 EXISTING)

DETENTION POND REQUIREMENTS

TOTAL POND AREA FROM T.O.B.: 7,030 SF

20% OF TOTAL AREA: 1,406 SF

REQUIRED TREES:5 (1 PER 300 SF OF THE

CALCULATED 20% AREA)

PROPOSED TREES:5

EAST BUFFER REQUIREMENTS

WIDTH: 8 FT

LENGTH: 330 LF

REQUIRED TREES: 13 TREES (1 PER 25 LF)

PROPOSED TREES: 13 TREES

REQUIRED SHRUBS: 1 HEDGE ROW

PROPOSED SHRUBS:1 HEDGE ROW

NUMBER INDICATED ONHATCH THROUGHOUTDRAWING REFLECTS THENUMBER OF PLANTS IN THATPARTICULAR AREA

MULCH: ALL SHRUB BEDS SHALL CONTAIN A 3" LAYER OF SHREDDED CYPRESS MULCH.

CONTRACTOR TO PLACE MIN. 4' DIAMETER CYPRESS MULCH CIRCLE AROUND ALL TREES IN SOD (TYP.)

COMMENTS

ILEX VOMITORIA

YAUPON HOLLY

5 GAL.

54" HT.

14 5'-0" O.C.

MATURE: 6-7' HT. / 5' WD.

ACACIA FARNESIANA

SWEET ACACIA

1.5" CAL.

6' HT.

15 AS SHOWN

MAGNOLIA GRANDIFLORA

SOUTHERN MAGNOLIA

1.5" CAL.

6' HT.

3 AS SHOWN

ILEX VOMITORIA 'SCHILLINGS'

SHILLINGS HOLLY

3 GAL.

18" GAL.

41 3'-0" O.C.

12WA

TE

R

ME

TE

R

32

1

32

1

32

1

32

1

32

1

654

32

1

654

32

1

54

2

1

654

2

1

654

2

654

2

654

32

1

6

54

32

1

6

54

32

1

3

3

654

32

6

54

6

54

32

1

6

54

32

1

4

32

1

4

32

1

6

54

32

1

6

54

32

1

54

32

1

32

1

6

54

32

1

6

54

32

1

6

54

32

1

654

32

1

6

54

32

1

6

54

3

2

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

6

32

1

32

1

32

1

32

1

6

54

54

32

1

32

1

3

2

1

3

2

1

32

1

6

54

32

1

6

54

32

1

6

54

3

2

1

6

54

3

2

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

6

5

32

1

6

54

32

1

654

32

1

32

1

32

1

32

1

32

1

3

32

1

3

54

3

3

3

3

3

3 1

32

1

6

54

3

2

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

3

2

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

5

2

1

1

1

32

1

32

1

WA

TE

R

ME

TE

R

2

3

3

4

6

2

1

E. T

AR

PO

N A

VE

NU

E

E. JASMINE AVENUE

EXISTING

CYCADIA

CEMETERY

EX

IS

TIN

G S

ID

EW

AL

K

E. JASMINE AVENUE

EX

IS

TIN

G S

OD

T

O R

EM

AIN

WETLAND

EXISTING FIBER OPTIC

PULL BOX TO REMAIN

EXISTING TRAFFIC

CONTROL UTILITY

CABINETS AND

CONCRETE PADS

TO REMAIN

PROPOSED ORNMANETAL

FENCE AND COLUMNS (TYP.).

SEE CIVIL PLANS FOR MORE

INFORMATION

EX

IS

TIN

G S

ID

EW

AL

K

PR

OP

OS

ED

S

ID

EW

AL

K

PROPOSED ENTRY

MONUMENT. SEE CIVIL

PLANS FOR MORE

INFORMATION

EXISTING UTILITY

PEDESTAL TO REMAIN

SOD LIMIT

LINE (TYP)

8

1

0

4

6

8

8

8

12

1

4

1

6

1

8

MINOR CLEARING AND

PRUNING LIMITS.

SEE NOTE ABOVE

ONE FOOT OF

MULCH TO BE

INSTALLED IN

FRONT AND

BEHIND FENCE

(TYP. OF ALL)

EXISTING POWER LINE

POLE

1

0

1

5

6

7

8

9

9

9

1

1

11

11

1

2

1

2

1

3

1

4

1

6

1

7

1

8

5

5

1

0

1

5

6

6

7

7

8

8

9

9

1

1

1

2

1

3

1

4

STORMWATER POND

SEE CIVIL PLANS FOR MORE INFORMATION

20' BUILDING

SETBACK

15' WETLAND

BUFFER

20' BUILDING

SETBACK

PROPOSED CHAIN LINK

FENCE (TYP.). SEE CIVIL

PLANS FOR MORE

INFORMATION

MINOR CLEARING AND PRUNING NOTE:

CONTRACTOR WILL BE REQUIRED TO

PERFORM MINOR CLEARING AND PRUNING

FOR THE TREE SAVE AREA BETWEEN THE

SOD EDGE AND WETLAND AREA. THIS WILL

INCLUDE REMOVAL OF GENERAL DEBRIS,

INCLUDING TREES 2" CAL. OR LESS,

HANGING LIMBS, DEAD LIMBS ON TREES

AND ON THE GROUND. PINE NEEDLES WILL

BE REQUIRED WITHIN THE

AFOREMENTIONED AREA.

CYCADIA CEMETERY EAST

(PHASE I)

SEPTEMBER 2019

CITY OF

TARPON SPRINGS

00287-011.01

ANDREW HILL, PLA

LA6667073

PROJECT NO:

DATE:

SHEET NO:

LIC. NO.:

DATE

BY DATEDESCRIPTIONNO.

DESIGNED

DRAWN

Q.C.

APPROVED

CJC, JLG

CJC, JLG

CJC

LA 6667073

STATE

OF

A

N

D

R

E

W

D

.

H

I

L

L

CLEARWATER

380 PARK PLACE BLVD, STE 300, CLEARWATER, FL 33759

TEL: (727) 531 - 3505 FAX: (727) 431 - 1777

www.cardno.com Certificate of Authorization No. 29915

09-20-19

00 20' 40'

MATCHLINE-SEE SHEET L 1.01

PLANTING PLAN

L1.00

NOTE: ALL SOD TO BE

PLACED WITHIN POND SHALL

BE HARVESTED FROM

NON-MUCK GROWN FARMS.

MATCHLINE-SEE SHEET L 1.01

Page 2: E. JASMINE AVENUE · 9as shown podocarpus macrophylla podocarpus 5 gal. 54" ht. 1905'-0" o.c. mature: 6-7' ht. / 5' wd. liriope muscari big blue lily turf 1 gal.1961'-6" o.c. stenotaphrum

32

1

32

1

32

1

32

1

32

1

32

1

2

1

32

1

32

1

32

1

32

1

32

1

32

1

32

6

54

32

6

54

32

1

6

54

32

1

6

54

6

54

6

5

32

1

6

54

32

1

6

54

32

1

6

54

654

32

1

654

32

1

654

32

1

6

54

2

1

6

32

6

54

32

6

54

32

1

654

32

1

654

32

1

654

32

1

654

32

1

654

32

1

654

1

6

32

1

6

54

32

1

6

54

32

1

6

54

32

1

654

32

1

654

32

1

654

32

1

654

32

1

32

1

32

1

32

1

1

32

1

54

2

1

1

32

1

6

54

6

54

32

1

6

54

32

1

6

54

6

54

6

54

32

1

6

54

32

1

6

54

32

1

6

54

6

6

32

1

6

54

32

1

6

54

6

5

3

32

1

32

32

1

2

1

2

1

3

32

1

4

32

1

4

4

2

1

32

1

54

32

1

4

1

1

3

32

1

6

54

3

3

5

5

5

1

12

:1

MA

X

12:1

MAX

12:1

MAX

E. T

AR

PO

N A

VE

NU

E

61

156

EX

IS

TIN

G S

ID

EW

ALK

EX

IS

TIN

G A

SP

HA

LT

PA

D T

O R

EM

AIN

EX

IS

TIN

G S

OD

T

O R

EM

AIN

MAUSOLEUM

FUTURE

PHASE II

COMMITTAL

SHELTER

EXISTING

HYDRANT TO

REMAIN

EXISTING WELL TO REMAIN

PROPOSED SIDEWALK

PROPOSED SIDEWALK

1

0

2

0

1

2

1

4

1

6

1

8

2

2

2

4

2

6

2

0

2

2

2

4

2

6

ONE FOOT OF

MULCH TO BE

INSTALLED IN

FRONT AND

BEHIND FENCE

(TYP. OF ALL)

1

0

1

0

15

1

5

2

0

2

0

11

1

1

1

2

1

2

1

3

1

3

1

4

1

4

16

1

6

1

7

17

1

8

1

8

1

9

1

9

2

1

2

1

21

2

1

21

22

2

2

2

3

2

4

8' LANDSCAPE BUFFER

20' BUILDING

SETBACK

PROPOSED 5' RETAINING WALL

SEE CIVIL SET FOR FURTHER

INFORMATION

PROPOSED ORNMANETAL

FENCE AND COLUMNS (TYP.).

SEE CIVIL PLANS FOR MORE

INFORMATION

PROPOSED CHAIN LINK

FENCE (TYP.). SEE CIVIL

PLANS FOR MORE

INFORMATION

ENTIRE AREA AROUND WELL

TO BE MULCHED

37

79

1. CONTRACTOR IS REQUIRED TO PERFORM MINOR CLEARING AND GRUBBING SERVICES FOR ENTIRE SITE PRIOR TO INSTALLING PLANT MATERIAL.

THIS INCLUDES BUT IS NOT LIMITED TO REMOVAL OF WEEDS, TRASH, AND SCRUB LIKE MATERIAL. IT IS POSSIBLE THIS MAY INCLUDE SOME FINE

GRADING SERVICES TO ASSURE NO HOLES OR TRIPPING HAZARDS ARE PRESENT. CONTRACTOR SHOULD INCLUDE THIS IN BID PRICE.

2. CONTRACTOR SHALL NOTIFY CARDNO IMMEDIATELY IF EXISTING TREES SHOWN ON THIS PLAN AS REMAINING DO NOT EXIST. ADDITIONAL PLANT

MATERIAL MAY BE REQUIRED TO ACCOUNT FOR MISSING TREES.

3. ALL EXISTING PALMS SLATED TO REMAIN SHALL BE CLEANED UP AND DEBOOTED UP TO A REASONABLE HEIGHT APPROPRIATE TO OVERALL

HEIGHT. ALL VINES ON EXISTING TREES SHALL BE REMOVED.

4. AREAS OF THE LAWN MAY CONTAIN CATCH BASINS AND AREA DRAINS. CONTRACTOR SHALL USE BEST JUDGEMENT TO FINE GRADE AROUND

CATCH BASINS AND OTHER APPURTENANCES TO MINIMIZE EROSION AND MAINTAIN AESTHETIC VALUE. TREES LOCATED IN DRAINAGE WAYS

SHALL BE FIELD ADJUSTED TO PLACE TREES OUTSIDE OF DRAINAGE WAY. CONTACT LANDSCAPE ARCHITECT WITH ANY DISCREPANCIES.

5. CONTRACTOR TO FLAG ALL PROPERTY LINES, EASEMENT LINES, ETC. TO INSTALL PLANTING AND IRRIGATION AS PER PLANS. CONTRACTOR TO

CONTACT OWNER AND LANDSCAPE ARCHITECT PRIOR TO INSTALLATION IF ANY LOCATIONS ARE UNCLEAR

GENERAL LANDSCAPE NOTES

MISCELLANEOUSITEM SIZE COMMENTS

GROUNDCOVERS/SODITEM SIZE QUANTITY SPACING

LANDSCAPE PLANT MATERIAL SCHEDULETREESITEM SIZE QUANTITY SPACING

SHRUBS & ACCENTSITEM SIZE QUANTITY SPACING

SYMBOL

EXISTING TREES TO REMAIN, EVERGREEN & DECIDUOUS

CONTRACTOR TO PROTECT WITHIN DRIP LINES

SEE TREE PROTECTION

& DEMOLITION PLANS

TAXODIUM DISTICHUM

BALD CYPRESS

1.5" CAL.

6' HT.

7 AS SHOWN

QUERCUS VIRGINIANA

LIVE OAK

1.5" CAL.

6' HT.

10 AS SHOWN

ULMUS AMERICANA V. FLORIDANA

FLORIDA ELM

1.5" CAL.

6' HT.

9 AS SHOWN

PODOCARPUS MACROPHYLLA

PODOCARPUS

5 GAL.

54" HT.

190 5'-0" O.C.

MATURE: 6-7' HT. / 5' WD.

LIRIOPE MUSCARI

BIG BLUE LILY TURF

1 GAL. 196 1'-6" O.C.

STENOTAPHRUM SECUNDATUM 'SAPPHIRE'

ST. AUGUSTINE SAPPHIRE

SOD94,000 SF

LANDSCAPE ORDINANCE REQUIREMENTS:

MINIMUM PLANTING REQUIREMENT

SITE AREA:125,670 SF (DOES NOT INCLUDE

WETLAND AREA OR DETENTION POND)

MINIMUM REQUIRED TREES: 71 TREES (8 FOR FIRST 15,000SF

AND 1 FOR EVERY 2,000SF IN EXCESS

OF THAT)

EXISTING TREES RETAINED: 43 TREES

PROPOSED TREES: 44 TREES

TOTAL TREES: 87 TREES

VUA REQUIREMENTS

PROPOSED PARKING SPACES: 43 SPACES

REQUIRED INTERIOR LANDSCAPE AREA:800 SF

PROPOSED INTERIOR LANDSCAPE AREA:2,245 SF

REQUIRED TREES: 8 TREES

PROPOSED TREES: 8 TREES (6 PROPOSED AND 2 EXISTING)

DETENTION POND REQUIREMENTS

TOTAL POND AREA FROM T.O.B.: 7,030 SF

20% OF TOTAL AREA: 1,406 SF

REQUIRED TREES: 5 (1 PER 300 SF OF THE

CALCULATED 20% AREA)

PROPOSED TREES: 5

EAST BUFFER REQUIREMENTS

WIDTH: 8 FT

LENGTH:330 LF

REQUIRED TREES: 13 TREES (1 PER 25 LF)

PROPOSED TREES:13 TREES

REQUIRED SHRUBS: 1 HEDGE ROW

PROPOSED SHRUBS: 1 HEDGE ROW

NUMBER INDICATED ONHATCH THROUGHOUTDRAWING REFLECTS THENUMBER OF PLANTS IN THATPARTICULAR AREA

MULCH: ALL SHRUB BEDS SHALL CONTAIN A 3" LAYER OF SHREDDED CYPRESS MULCH.

CONTRACTOR TO PLACE MIN. 4' DIAMETER CYPRESS MULCH CIRCLE AROUND ALL TREES IN SOD (TYP.)

COMMENTS

ILEX VOMITORIA

YAUPON HOLLY

5 GAL.

54" HT.

14 5'-0" O.C.

MATURE: 6-7' HT. / 5' WD.

ACACIA FARNESIANA

SWEET ACACIA

1.5" CAL.

6' HT.

15 AS SHOWN

MAGNOLIA GRANDIFLORA

SOUTHERN MAGNOLIA

1.5" CAL.

6' HT.

3 AS SHOWN

ILEX VOMITORIA 'SCHILLINGS'

SHILLINGS HOLLY

3 GAL.

18" GAL.

41 3'-0" O.C.

12

CYCADIA CEMETERY EAST

(PHASE I)

SEPTEMBER 2019

CITY OF

TARPON SPRINGS

00287-011.01

ANDREW HILL, PLA

LA6667073

PROJECT NO:

DATE:

SHEET NO:

LIC. NO.:

DATE

BY DATEDESCRIPTIONNO.

DESIGNED

DRAWN

Q.C.

APPROVED

CJC, JLG

CJC, JLG

CJC

LA 6667073

STATE

OF

A

N

D

R

E

W

D

.

H

I

L

L

CLEARWATER

380 PARK PLACE BLVD, STE 300, CLEARWATER, FL 33759

TEL: (727) 531 - 3505 FAX: (727) 431 - 1777

www.cardno.com Certificate of Authorization No. 29915

09-20-19

MATCHLINE-SEE SHEET L 1.00

00 20' 40'

PLANTING PLAN

L1.01

MATCHLINE-SEE SHEET L 1.00

Page 3: E. JASMINE AVENUE · 9as shown podocarpus macrophylla podocarpus 5 gal. 54" ht. 1905'-0" o.c. mature: 6-7' ht. / 5' wd. liriope muscari big blue lily turf 1 gal.1961'-6" o.c. stenotaphrum

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

5

4

2

1

6

5

4

2

1

6

5

4

2

6

5

4

2

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

3

3

6

5

4

3

2

6

5

4

6

5

4

3

2

1

6

5

4

3

2

1

4

3

2

1

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

5

4

3

2

1

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

6

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

2

1

3

2

1

3

2

1

3

2

1

3

2

1

6

5

4

5

4

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

6

5

4

3

2

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

6

5

4

6

5

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

6

5

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

2

1

6

3

2

6

5

4

3

2

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

1

6

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

1

3

2

1

5

4

3

2

1

3

2

1

3

2

1

2

1

3

3

2

1

3

5

4

1

3

3

3

3

3

3

1

3

2

1

6

5

4

3

2

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

6

5

4

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

3

2

1

6

5

4

3

2

1

6

5

4

3

2

1

6

5

4

6

6

3

2

1

6

5

4

3

2

1

6

5

4

6

5

3

3

2

1

3

2

3

2

1

2

1

1

1

3

2

1

3

2

1

2

1

2

1

3

3

2

1

4

3

2

1

4

4

2

1

3

2

1

5

4

3

2

1

4

1

1

2

3

3

3

4

3

2

1

6

2

6

5

4

3

3

5

1

5

5

1

12:1

MAX

12:1

MA

X

12:1

MA

X

IRRIGATION MATERIALS AND LEGEND

UNDERPAVEMENT SLEEVING.

PVC SCH 40 - ALL ROADWAY CROSSINGS SHALL HAVE (1)

4" SLEEVE WITH (2) 2" SLEEVES. ALL OTHER SLEEVES TO

BE 4" UNLESS OTHERWISE NOTED.

NOTE: CONTRACTOR TO PROVIDE ANY NECESSARY

SLEEVING UNDER PAVEMENT NOT SHOWN IN PLANS

2" IRRIGATION MAINLINE - SOLVENT WELD PVC (PURPLE PIPE)

ASTM D2241 - CLASS 200 - SDR 21

QUICK COUPLING VALVE AND VALVE KEY

MFG.: RAINBIRD (MODEL: 5 NP)

RESILIENT WEDGE ISOLATION VALVE - SIZE PER LINE

STAINLESS STEEL BALL VALVE - SIZE PER LINE

MFG.: LEEMCO FITTINGS (MODEL: LBT-XX-SS)

GENERAL NOTES:

1. IRRIGATION SYSTEM DESIGN IS BASED ON 32 GPM AND 105 PSI. SUPPLY PRESSURE IS 40 PSI. A

BOOSTER PUMP IS REQUIRED TO OPERATE AS DESIGNED.

2. IRRIGATION DESIGN IS FROM THE POINT OF CONNECTION (POC) ONLY. THE DESIGN IS BASED ON

GALLONS PER MINUTE (GPM) AND POUNDS PER SQUARE INCH (PSI) AS FURNISHED BY OTHERS.

3. IRRIGATION CONTRACTOR TO VERIFY POINT OF CONNECTION IN THE FIELD AND CONFIRM MINIMUM

DISCHARGE REQUIRED AT POINT OF CONNECTION AS REQUIRED BY PROPOSED IRRIGATION

EQUIPMENT PRIOR TO INSTALLATION. CONTACT OWNER'S REPRESENTATIVE WITH ANY

DISCREPANCIES IMMEDIATELY BEFORE INSTALLATION.

4. THE PRESSURE REQUIREMENT AT THE POINT OF CONNECTION IS BASED ON NO MORE THAN 5 FEET

OF ELEVATION CHANGE IN THE AREAS OF IRRIGATION.

5. DETAILED AS-BUILTS WILL BE REQUIRED UPON COMPLETION OF PROJECT. AS-BUILTS TO INCLUDE

ALL DECODER ADDRESSES AS WELL AS GPS LOCATIONS OF EACH VALVE BOX. SEE DETAIL SHEET

FOR FURTHER INFORMATION

6. CONTRACTOR TO USE CONTINUOUS RUNS FOR ALL PROPOSED CONTROL WIRES. IF NECESSARY,

LOCATE ALL WIRE SPLICES IN VALVE BOX. BUNDLE WIRES IN VALVE BOX WITH MINIMUM 24" OF

EXCESS CABLE PER BUNDLE. ALL SPLICES MUST BE WATERPROOF WITH 3M DBY/DBR-6

CONNECTORS.

7. ALL MATERIAL USED SHALL BE INSTALLED AS PER PLAN AND AS PER MANUFACTURER'S

SPECIFICATIONS. ALL DEVIATIONS FROM DRAWINGS OR MATERIALS SHALL BE APPROVED BY THE

OWNER OR LANDSCAPE ARCHITECT.

8. CONTRACTOR TO PROVIDE ANY STAKING NECESSARY FOR PROPERTY LINES, EASEMENT LINES, ETC.

TO INSTALL PLANTING AND IRRIGATION AS PER PLANS

9. LOCATE VALVES AND VALVE BOXES IN SHRUB BED WHENEVER POSSIBLE. IF NECESSARY TO LOCATE

IN LAWN, LOCATE A MINIMUM OF 36" AWAY FROM PLANTER BED EDGE.

10. CONTRACTOR IS RESPONSIBLE TO ENSURE THAT ALL IRRIGATION EQUIPMENT IS MARKED

APPROPRIATELY TO DESIGNATE NON-POTABLE WATER AND WITH PURPLE INDICATORS. ALL VALVE

BOXES SHALL HAVE PURPLE LIDS WITH TEXT THAT READS "DO NOT DRINK". ALL PIPES TO BE

PURPLE PIPE. ALL IRRIGATION HEADS WILL HAVE PURPLE CAPS

11. PIPE LAYOUT AND VALVE LOCATION IS DIAGRAMMATIC. VALVES AND PIPE SHOWN IN BUILDING OR

PAVED AREAS ARE FOR GRAPHIC CLARITY ONLY. ALL VALVES AND MAINLINE SHALL BE INSTALLED

WITHIN LANDSCAPE AREAS WITHIN PROPERTY. LOCATION OF IRRIGATION COMPONENTS SHOWN

ON DRAWING IS APPROXIMATE. ACTUAL PLACEMENT MAY VARY SLIGHTLY AS REQUIRED TO

ACHIEVE FULL, EVEN COVERAGE.

12. LAWN INTERIOR WILL BE DEVIDED INTO BLOCK, LOT AND GRAVE. NO IRRIGATION PIPE OR

EQUIPMENT OF ANY KIND WILL BE ALLOWED WITHIN BLOCKS. IRRIGATION CONTRACTOR TO

REFERENCE GEOMETRIC CONTROL PLAN FOR LOT & GRAVE DETAIL. CONTACT OWNER'S

REPRESENTATIVE WITH ANY DISCREPANCIES.

13. SEE DETAIL SHEET L 3.01 FOR FURTHER IRRIGATION NOTES & DETAILS

AUTOMATIC CONTROLLER WITH CENTRAL CONTROL

RAINBIRD (MODEL: ESP-LXD50)

IQ CENTRAL CONTROL: IQ-NCC

STAINLESS STEEL PEDESTAL AND CABINET: LXMMSSPED & ESP-LXMMSS

WIRELESS RAIN SENSOR - RAINBIRD (MODEL: WR2-RFC)

TO BE INSTALLED ON ROOF OF BUILDING IF APPROVED BY

OWNER. RAIN SENSOR SHALL BE INSTALLED PER

MANUFACTURER RECOMMENDATION

SURGE PROTECTOR/GROUNDING PLATE.

MFG.: RAINBIRD SENSOR DECODER (MODEL: LSP-1)

INSTALL EVERY 500' OF CONTROL WIRE OR 10 DECODERS, WHICHEVER IS

LESSER

EARTH GROUND RESISTANCE READINGS TO BE 10 OHMS OR LESS.

RESISTANCE READINGS WILL BE REQUIRED TO BE TESTED BY CONTRACTOR

AND A REPORT VERIFYING READINGS HAVE MET SPECIFICATIONS SUBMITTED

TO OWNER PRIOR TO FINAL PAYMENT BEING RELEASED.

DC

DECODER CABLE FUSE DEVICES (DCFD) (MFG: PAIGE MODEL: DCFD)

CONTRACTOR TO INSTALL (DCFD) AT ALL DIRECTIONAL SPLICES IN A VALVE BOX.

CONTRACTOR TO PROVIDE ANY NECESSARY (DCFD) NOT SHOWN IN PLANS

PIPE, SLEEVING AND COMMUNICATION WIRE

TWO-WIRE CONTROL WIRE. 14 AWG

CONTRACTOR TO EXTEND CONTROL WIRE TO ALL VALVES AND STUB OUTS

AS SHOWN.

CONTRACTOR TO USE CONTINUOUS RUNS FOR ALL PROPOSED CONTROL

WIRES. IF NECESSARY, LOCATE ALL WIRE SPLICES IN VALVE BOX. BUNDLE

WIRES IN VALVE BOX WITH MINIMUM 24" OF EXCESS CABLE PER BUNDLE.

ALL SPLICES MUST BE WATERPROOF WITH 3M DBY/DBR-6 CONNECTORS.

MV FS

MASTER VALVE & FLOW SENSOR - SEE SHEET L2.01

MASTER VALVE: RAINBIRD (MODEL: 200-EFB-CP-PRS-D)

FLOW SENSOR: RAINBIRD (MODEL: FS150B)

INSTALL PER MANUFACTURER RECOMMENDATIONS

BP

POINT OF CONNECTION IS A 1" RECLAIMED METER. PRESSURE

READING PROVIDED BY CITY IS 40 PSI AFTER METER.

BOOSTER PUMP - DESIGN/BUILD BY IRRIGATION CONTRACTOR

00 30' 60'

EXISTING

CYCADIA

CEMETERY

TARPON

SPRINGS

YOUTH

SOCCER

E. TARPON AVENUE

N. JASM

IN

E AVEN

UE

MAUSOLEUM

FUTURE

PHASE II

CO

MM

ITTAL

SH

ELTER

STO

RM

WATER

PO

ND

DESIGN/BUILD NOTE: PORTIONS OF THE IRRIGATION SYSTEM HAVE BEEN DESIGNED AND SPECIFIED BY

CARDNO. THE INTERIOR OF THE SITE WILL BE DESIGN/BUILD BY IRRIGATION CONTRACTOR. THESE

AREAS WILL INCLUDE ALL PROPOSED PLANTINGS AND TURF AREAS NOT CURRENTLY IRRIGATED WITHIN

THIS IRRIGATION PLAN. ALL OTHER AREAS TO BE BID AND INSTALLED AS PER PLAN. BELOW ARE KNOWN

REQUIREMENTS TO ADHERE TO FOR THE PREPARATION OF DESIGN DOCUMENTS:

· THE INTERIOR LAWN WILL BE DIVIDED INTO BLOCK, LOT AND GRAVE. NO IRRIGATION LINES OR

EQUIPMENT ARE ALLOWED WITHIN THE BLOCKS. REFER TO GEOMETRIC CONTROL PLAN FOR BLOCK,

LOT AND GRAVE DETAILS.

· HEADSTONES WILL BE UTILIZED IN LOTS. IRRIGATION LAYOUT AND COVERAGE SHOULD

ACCOMMODATE HEADSTONES

· IT IS ANTICIPATED THAT 60 PSI ROTORS WILL BE NEEDED TO IRRIGATE THE TURF AREAS

IN-BETWEEN GRAVES FROM THE PERIMETER OF THE GRAVE BLOCKS. THERE ARE A TOTAL OF THREE

BLOCKS

· IT IS ANTICIPATED THAT THE FINAL DESIGN WILL REQUIRE A BOOSTER PUMP CAPABLE OF

PRODUCING OVER 100 PSI. CONTRACTOR WILL BE REQUIRED TO SPECIFY AND INSTALL BOOSTER

PUMP CAPABLE OF MEETING DESIGN REQUIREMENTS

WETLAND

OVERALL MAINLINE

ROUTING PLAN

L2.00

DC

DC

CYCADIA CEMETERY EAST

(PHASE I)

SEPTEMBER 2019

CITY OF

TARPON SPRINGS

00287-011.01

ANDREW HILL, PLA

LA6667073

PROJECT NO:

DATE:

SHEET NO:

LIC. NO.:

DATE

BY DATEDESCRIPTIONNO.

DESIGNED

DRAWN

Q.C.

APPROVED

CJC, JLG

CJC, JLG

CJC

LA 6667073

STATE

OF

A

N

D

R

E

W

D

.

H

I

L

L

CLEARWATER

380 PARK PLACE BLVD, STE 300, CLEARWATER, FL 33759

TEL: (727) 531 - 3505 FAX: (727) 431 - 1777

www.cardno.com Certificate of Authorization No. 29915

09-20-19

DC

DC

Page 4: E. JASMINE AVENUE · 9as shown podocarpus macrophylla podocarpus 5 gal. 54" ht. 1905'-0" o.c. mature: 6-7' ht. / 5' wd. liriope muscari big blue lily turf 1 gal.1961'-6" o.c. stenotaphrum

32

1

32

1

32

1

32

1

32

1

6

54

32

1

6

54

32

1

54

2

1

654

2

1

654

2

654

2

654

32

1

654

32

1

654

32

1

3

3

6

54

32

6

54

6

54

32

1

6

54

32

1

4

32

1

4

32

1

6

54

32

1

6

54

32

1

54

32

1

32

1

6

54

32

1

6

54

32

1

6

54

32

1

654

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

3

2

1

6

54

32

1

6

54

32

1

6

54

6

32

1

32

1

32

1

32

1

6

54

54

32

1

32

1

32

1

32

1

32

1

6

54

32

1

6

54

32

1

654

32

1

654

32

1

654

32

1

654

32

1

654

32

1

654

32

1

654

32

1

654

32

1

654

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

6

5

32

1

6

54

32

1

6

54

32

1

32

1

32

1

32

1

3

2

1

3

3

2

1

3

54

3

3

3

3

3

3 1

32

1

654

32

654

32

1

654

32

1

654

32

1

654

32

1

654

32

1

6

54

32

1

6

54

32

1

6

54

32

1

6

54

32

1

654

32

1

6

54

32

1

6

5

2

1

1

1

32

1

32

1

2 3

3

4

6

2

1

NOTE: EASEMENT LINES HAVE BEEN REMOVED

FROM IRRIGATION PLAN FOR GRAPHICAL CLARITY.

REFER TO PLANTING AND SITE PLAN FOR

EASEMENT LINE AND LOCATION.

NOTE: PIPE LAYOUT AND VALVE LOCATION IS

DIAGRAMMATIC. VALVES AND PIPE SHOWN IN

BUILDING OR PAVED AREAS ARE FOR GRAPHIC

CLARITY ONLY. ALL VALVES AND MAINLINE SHALL BE

INSTALLED WITHIN LANDSCAPE AREAS WITHIN

PROPERTY. LOCATION OF IRRIGATION COMPONENTS

SHOWN ON DRAWING IS APPROXIMATE. ACTUAL

PLACEMENT MAY VARY SLIGHTLY AS REQUIRED TO

ACHIEVE FULL, EVEN COVERAGE. NO EQUIPMENT IS

ALLOWED WITHIN GRAVE LOTS

NOTE: NO MAINLINE SHALL BE INSTALLED IN RIGHT

OF WAY. CONTRACTOR TO LIMIT THE AMOUNT OF

LATERALS WITHIN RIGHT OF WAY AT ALL TIMES.

POINT OF CONNECTION

IS LOCATED IN THIS APPROXIMATE AREA. POINT OF

CONNECTION IS A 1" INCH METER PROVIDED AND

INSTALLED BY OWNER. COORDINATE WITH OWNER ON

EXACT LOCATION AND SCHEDULE OF INSTALLATION.

BOOSTER PUMP TO BE INSTALLED WITHIN PLANTING BED

BEHIND FENCE AND CONCEALED BY PLANTINGS AS BEST AS

POSSIBLE FROM E. JASMINE AVENUE

AUTOMATIC IRRIGATION CONTROLLER

IRRIGATION CONTRACTOR TO COORDINATE POWER SUPPLY

PRIOR TO CONSTRUCTION. CONSULT OWNER'S

REPRESENTATIVE ON FINAL LOCATION PRIOR TO POURING

CONTROLLER FOOTING. CONTROLLER SHALL BE LOCATED

WITHIN PROPOSED PLANTING BED BEHIND FENCE AND

CONCEALED BY PLANTINGS AS BEST AS POSSIBLE FROM E.

JASMINE AVENUE. CONTRACTOR TO INSTALL WIRELESS RAIN

SENSOR ON COLUMN' NEAR CONTROLLER. CONTRACTOR TO

ENSURE RAIN SENSOR IS OUT OF CURRENT AND FUTURE

DRIPLINE OF TREES IN IMMEDIATE AREA.

MVFS

EXISTIN

G SID

EW

ALK

EXISTIN

G SID

EW

ALK

SID

EW

ALK

E. T

AR

PO

N A

VE

NU

E

E. JASMINE AVENUE

E. JASMINE AVENUE

STORMWATER POND

SEE CIVIL PLANS FOR MORE INFORMATION

SIDEWALK

RIG

HT O

F W

AY

RIGHT OF WAY

RIG

HT O

F W

AY

1

30

3

28

2

--

4

30

5

30

6

19.5

7

11

8

--

32

30

19

--

BP

RIGHT OF WAY

SID

EW

ALK

15'

IRRIGATION MATERIALS AND LEGEND

PIPE, SLEEVING AND COMMUNICATION WIRE

SYM P.S.I. RADIUS

3.70, 2.78, 1.85, .92 30

12'302.60, 1.95, 1.3, .65

DESCRIPTION

1.58, .79, .39

GPM

30 10'

8'1.05, .52, .26 30

1.21 4' X 24'

30 4' X 12'

SPRAY HEADS

.61

30

UNDERPAVEMENT SLEEVING.

PVC SCH 40 - ALL ROADWAY CROSSINGS SHALL HAVE (1)

4" SLEEVE WITH (2) 2" SLEEVES. ALL OTHER SLEEVES TO

BE 4" UNLESS OTHERWISE NOTED.

NOTE: CONTRACTOR TO PROVIDE ANY NECESSARY

SLEEVING UNDER PAVEMENT NOT SHOWN IN PLANS

RAINBIRD RD-06-S-P30-NP-15SST POP-UP SPRINKLER

RAINBIRD RD-06-S-P30-NP-15EST POP-UP SPRINKLER

RAINBIRD RD-06-S-P30-NP-8 SPRAY POP-UP SPRINKLER, F, H, Q,

RAINBIRD RD-06-S-P30-NP-10 POP-UP SPRINKLER, F, H, Q

RAINBIRD RD-06-S-P30-NP-12 POP-UP SPRINKLER, F, TQ, H, Q

RAINBIRD RD-06-S-P30-NP-15 POP-UP SPRINKLER, F, TQ, H, Q

GPM 20-50 MFG.: 1 1/2" RAINBIRD VALVE (MODEL: 150-PESBR-PRS-D)

1

34

CONTROLLER VALVES AND APPURTENANCES

1" XERIGATION COMMERCIAL CONTROL ZONE KIT -

MFG.: RAINBIRD - MODEL: XCZ-100-PRBR

USE PSI-M30X REGULATOR FOR FLOWS EXCEEDING 5 GPM

GPM 0-20 MFG.: 1" RAINBIRD VALVE (MODEL: 100-PESBR-PRS-D)

DRIP IRRIGATION STATION NUMBER

LATERAL PIPE-CLASS 200-PURPLE PIPE

STATION NUMBER

GALLONS PER MINUTE

(CONTRACTOR TO LABEL VALVES IN CONTROLLER AND

AS BUILTS ACCORDING TO DECODER ADDRESS)

TWO WIRE FIELD DECODER FOR REMOTE CONTROL VALVE

MFG.: RAINBIRD FD-SERIES DECODER (MODEL: FD-101)

11

--

GALLONS PER MINUTE

DRIP IRRIGATION NOTES:

1. ALL 1/2" POLY TUBING TO BE SECURED BY RAINBIRD

EASY FIT COMPRESSION FITTINGS

2. 1/4" TUBING NOT TO EXCEED 5 LF, RAINBIRD MODEL

PT-025. 1/4" BARB TRANSFER FITTINGS TO BE

RAINBIRD

3. INSTALL ONE RAINBIRD XERI-SPRAY (MODEL XS-90) ON

12" POLY FLEX RISER ON EACH DRIP ZONE FOR USUAL

INSPECTION OF SYSTEM. INSTALL 3' FROM VALVE BOX,

ABOVE GRADE MINIMUM 5' FROM PAVEMENT EDGE.

4. EMITTER SCHEDULE - 2.5" CALIPER TREES (PLANTING

BEDS ONLY) - 14 GPH; SHRUB - 5 GPH; GROUNDCOVER -

1 GPH.

DRIP IRRIGATION

IRRIGATION LATERALS TO BE SIZED

ACCORDING TO FLOW CHART AND

FLOWS ACCUMULATED. PIPE SIZES

SHALL BE ADJUSTED IN THE FIELD TO

MATCH AS-BUILT CONDITIONS.

CONTROLLER VALVES AND APPURTENANCES

LATERAL FLOW CHART

3/4" = 0-10 GPM

1" = 11-16 GPM

1 1/4" = 17-26 GPM

1 1/2" = 27-35 GPM

2" = 35-55 GPM

END FLUSH CAP (MODEL:MDCFCAP)

INSTALL IN VALVE BOX. TYPICAL AT ALL ENDS OF

XERI-TUBE RUNS

MV FS

PRESSURE REGULATING ELECTRIC REMOTE CONTROL VALVE AND

TWO WIRE DECODER

SHRUB ZONES: 1/2" DIA RAINBIRD BLACK STRIPE TUBING

NOT TO EXCEED 250 LF OR 4.0 GPM FOR ANY SINGLE RUN

MFG: RAINBIRD - MODEL: XBS 500P

CV

HEAD DRAINAGE

LOCATE AS NECESSARY TO AVOID LOW

1.73

KING BROS. IN LINE SWING CHECK VALVE

30

(MODEL # KSC-(LINE SIZE)-S

9' X 18'RAINBIRD RD-06-S-P30-NP-9SST POP-UP SPRINKLER

RAINBIRD RD-06-S-P30-NP-RVAN18 POP-UP SPRINKLER, F, H, Q 16'1.96, 1.01, .5

QUICK COUPLING VALVE AND VALVE KEY

MFG.: RAINBIRD (MODEL: 5 NP)

30

AUTOMATIC CONTROLLER WITH CENTRAL CONTROL

RAINBIRD (MODEL: ESP-LXD50)

IQ CENTRAL CONTROL: IQ-NCC

STAINLESS STEEL PEDESTAL AND CABINET: LXMMSSPED & ESP-LXMMSS

WIRELESS RAIN SENSOR - RAINBIRD (MODEL: WR2-RFC)

TO BE INSTALLED ON ROOF OF BUILDING IF APPROVED BY

OWNER. RAIN SENSOR SHALL BE INSTALLED PER

MANUFACTURER RECOMMENDATION

RESILIENT WEDGE ISOLATION VALVE - SIZE PER LINE

STAINLESS STEEL BALL VALVE - SIZE PER LINE

MFG.: LEEMCO FITTINGS (MODEL: LBT-XX-SS)

NOTE: REFER TO SHEET L2.00 FOR

ADDITIONAL DETAILS AND GENERAL NOTES

POINT OF CONNECTION IS A 1" RECLAIMED METER. PRESSURE

READING PROVIDED BY CITY IS 40 PSI AFTER METER.

BOOSTER PUMP - DESIGN/BUILD BY IRRIGATION CONTRACTORBP

MASTER VALVE & FLOW SENSOR

MASTER VALVE: RAINBIRD (MODEL: 200-EFB-CP-PRS-D)

FLOW SENSOR: RAINBIRD (MODEL: FS150B) WITH

SENSOR DECODER (SD210TURF)

INSTALL PER MANUFACTURER RECOMMENDATIONS

2" IRRIGATION MAINLINE - SOLVENT WELD PVC (PURPLE PIPE)

ASTM D2241 - CLASS 200 - SDR 21

SURGE PROTECTOR/GROUNDING PLATE.

MFG.: RAINBIRD SENSOR DECODER (MODEL: LSP-1)

INSTALL EVERY 500' OF CONTROL WIRE OR 10 DECODERS, WHICHEVER IS

LESSER

EARTH GROUND RESISTANCE READINGS TO BE 10 OHMS OR LESS.

RESISTANCE READINGS WILL BE REQUIRED TO BE TESTED BY CONTRACTOR

AND A REPORT VERIFYING READINGS HAVE MET SPECIFICATIONS SUBMITTED

TO OWNER PRIOR TO FINAL PAYMENT BEING RELEASED.

IRRIGATION PLAN

L2.01

00 20' 40'

MATCHLINE-SEE SHEET L 2.02 MATCHLINE-SEE SHEET L 2.02

CYCADIA CEMETERY EAST

(PHASE I)

SEPTEMBER 2019

CITY OF

TARPON SPRINGS

00287-011.01

ANDREW HILL, PLA

LA6667073

PROJECT NO:

DATE:

SHEET NO:

LIC. NO.:

DATE

BY DATEDESCRIPTIONNO.

DESIGNED

DRAWN

Q.C.

APPROVED

CJC, JLG

CJC, JLG

CJC

LA 6667073

STATE

OF

A

N

D

R

E

W

D

.

H

I

L

L

CLEARWATER

380 PARK PLACE BLVD, STE 300, CLEARWATER, FL 33759

TEL: (727) 531 - 3505 FAX: (727) 431 - 1777

www.cardno.com Certificate of Authorization No. 29915

09-20-19

NOTE: CONTRACTOR TO COORDINATE AND

OBTAIN ENCROACHMENT PERMIT PRIOR TO

INSTALLING IRRIGATION WITHIN THE

RIGHT OF WAY ALONG BOTH ROADS. NO

CONSTRUCTION MAY COMMENCE PRIOR TO

OBTAINING THE ENCROACHMENT PERMIT

ALONG E. TARPON SPRINGS AVENUE AND E.

JASMINE AVENUE

Page 5: E. JASMINE AVENUE · 9as shown podocarpus macrophylla podocarpus 5 gal. 54" ht. 1905'-0" o.c. mature: 6-7' ht. / 5' wd. liriope muscari big blue lily turf 1 gal.1961'-6" o.c. stenotaphrum

32

1

3

2

1

32

1

32

1

32

1

32

1

2

1

32

1

32

1

32

1

32

1

32

1

32

1

32

6

54

32

6

54

32

1

6

54

32

1

6

54

6

54

6

5

32

1

6

54

32

1

6

54

32

1

654

654

32

1

654

32

1

654

32

1

654

2

1

6

32

6

54

32

6

54

32

1

6

54

32

1

654

32

1

654

32

1

654

32

1

654

32

1

654

1

6

32

1

6

54

32

1

6

54

32

1

6

54

32

1

654

32

1

654

32

1

654

32

1

654

32

1

32

1

32

1

32

1

1

32

1

54

2

1

1

32

1

6

54

6

54

32

1

6

54

32

1

6

54

6

54

6

54

32

1

6

54

32

1

6

54

32

1

6

54

6

6

32

1

654

32

1

654

65

3

32

1

32

32

1

2

1

2

1

3

32

1

4

32

1

4

4

2

1

32

1

54

3

2

1

4

1

1

3

32

1

6

54

3

3

5

5

5

1

12:1

MA

X

12:1

MAX

12:1

MAX

EXISTIN

G SID

EW

ALK

EXISTIN

G SID

EW

ALK

E. T

AR

PO

N A

VE

NU

E

MAUSOLEUM

FUTURE

PHASE IICOMMITTAL

SHELTER

RIG

HT O

F W

AY

RIG

HT O

F W

AY

9

19.5

10

30

11

23

12

27

14

30

16

5

13

30

15

--

18

30

17

--

NOTE: NO MAINLINE SHALL BE INSTALLED IN RIGHT

OF WAY. CONTRACTOR TO LIMIT THE AMOUNT OF

LATERALS WITHIN RIGHT OF WAY AT ALL TIMES.

NOTE: PIPE LAYOUT AND VALVE LOCATION IS

DIAGRAMMATIC. VALVES AND PIPE SHOWN IN

BUILDING OR PAVED AREAS ARE FOR GRAPHIC

CLARITY ONLY. ALL VALVES AND MAINLINE SHALL BE

INSTALLED WITHIN LANDSCAPE AREAS BETWEEN

RIGHT-OF-WAY AND PROPERTY LINE. LOCATION OF

IRRIGATION COMPONENTS SHOWN ON DRAWING IS

APPROXIMATE. ACTUAL PLACEMENT MAY VARY

SLIGHTLY AS REQUIRED TO ACHIEVE FULL, EVEN

COVERAGE.

NOTE: EASEMENT LINES HAVE BEEN REMOVED

FROM IRRIGATION PLAN FOR GRAPHICAL CLARITY.

REFER TO PLANTING AND SITE PLAN FOR

EASEMENT LINE AND LOCATION.

SID

EW

ALK

SIDEWALK

SIDEWALK

15'

IRRIGATION MATERIALS AND LEGEND

PIPE, SLEEVING AND COMMUNICATION WIRE

SYM P.S.I. RADIUS

3.70, 2.78, 1.85, .92 30

12'302.60, 1.95, 1.3, .65

DESCRIPTION

1.58, .79, .39

GPM

30 10'

8'1.05, .52, .26 30

1.21 4' X 24'

30 4' X 12'

SPRAY HEADS

.61

30

UNDERPAVEMENT SLEEVING.

PVC SCH 40 - ALL ROADWAY CROSSINGS SHALL HAVE (1)

4" SLEEVE WITH (2) 2" SLEEVES. ALL OTHER SLEEVES TO

BE 4" UNLESS OTHERWISE NOTED.

NOTE: CONTRACTOR TO PROVIDE ANY NECESSARY

SLEEVING UNDER PAVEMENT NOT SHOWN IN PLANS

RAINBIRD RD-06-S-P30-NP-15SST POP-UP SPRINKLER

RAINBIRD RD-06-S-P30-NP-15EST POP-UP SPRINKLER

RAINBIRD RD-06-S-P30-NP-8 SPRAY POP-UP SPRINKLER, F, H, Q,

RAINBIRD RD-06-S-P30-NP-10 POP-UP SPRINKLER, F, H, Q

RAINBIRD RD-06-S-P30-NP-12 POP-UP SPRINKLER, F, TQ, H, Q

RAINBIRD RD-06-S-P30-NP-15 POP-UP SPRINKLER, F, TQ, H, Q

GPM 20-50 MFG.: 1 1/2" RAINBIRD VALVE (MODEL: 150-PESBR-PRS-D)

1

34

CONTROLLER VALVES AND APPURTENANCES

1" XERIGATION COMMERCIAL CONTROL ZONE KIT -

MFG.: RAINBIRD - MODEL: XCZ-100-PRBR

USE PSI-M30X REGULATOR FOR FLOWS EXCEEDING 5 GPM

GPM 0-20 MFG.: 1" RAINBIRD VALVE (MODEL: 100-PESBR-PRS-D)

DRIP IRRIGATION STATION NUMBER

LATERAL PIPE-CLASS 200-PURPLE PIPE

STATION NUMBER

GALLONS PER MINUTE

(CONTRACTOR TO LABEL VALVES IN CONTROLLER AND

AS BUILTS ACCORDING TO DECODER ADDRESS)

TWO WIRE FIELD DECODER FOR REMOTE CONTROL VALVE

MFG.: RAINBIRD FD-SERIES DECODER (MODEL: FD-101)

11

--

GALLONS PER MINUTE

DRIP IRRIGATION NOTES:

1. ALL 1/2" POLY TUBING TO BE SECURED BY RAINBIRD

EASY FIT COMPRESSION FITTINGS

2. 1/4" TUBING NOT TO EXCEED 5 LF, RAINBIRD MODEL

PT-025. 1/4" BARB TRANSFER FITTINGS TO BE

RAINBIRD

3. INSTALL ONE RAINBIRD XERI-SPRAY (MODEL XS-90) ON

12" POLY FLEX RISER ON EACH DRIP ZONE FOR USUAL

INSPECTION OF SYSTEM. INSTALL 3' FROM VALVE BOX,

ABOVE GRADE MINIMUM 5' FROM PAVEMENT EDGE.

4. EMITTER SCHEDULE - 2.5" CALIPER TREES (PLANTING

BEDS ONLY) - 14 GPH; SHRUB - 5 GPH; GROUNDCOVER -

1 GPH.

DRIP IRRIGATION

IRRIGATION LATERALS TO BE SIZED

ACCORDING TO FLOW CHART AND

FLOWS ACCUMULATED. PIPE SIZES

SHALL BE ADJUSTED IN THE FIELD TO

MATCH AS-BUILT CONDITIONS.

CONTROLLER VALVES AND APPURTENANCES

LATERAL FLOW CHART

3/4" = 0-10 GPM

1" = 11-16 GPM

1 1/4" = 17-26 GPM

1 1/2" = 27-35 GPM

2" = 35-55 GPM

END FLUSH CAP (MODEL:MDCFCAP)

INSTALL IN VALVE BOX. TYPICAL AT ALL ENDS OF

XERI-TUBE RUNS

MV FS

PRESSURE REGULATING ELECTRIC REMOTE CONTROL VALVE AND

TWO WIRE DECODER

SHRUB ZONES: 1/2" DIA RAINBIRD BLACK STRIPE TUBING

NOT TO EXCEED 250 LF OR 4.0 GPM FOR ANY SINGLE RUN

MFG: RAINBIRD - MODEL: XBS 500P

CV

HEAD DRAINAGE

LOCATE AS NECESSARY TO AVOID LOW

1.73

KING BROS. IN LINE SWING CHECK VALVE

30 9' X 18'

(MODEL # KSC-(LINE SIZE)-S

RAINBIRD RD-06-S-P30-NP-9SST POP-UP SPRINKLER

RAINBIRD RD-06-S-P30-NP-RVAN18 POP-UP SPRINKLER, F, H, Q 16'1.96, 1.01, .5

QUICK COUPLING VALVE AND VALVE KEY

MFG.: RAINBIRD (MODEL: 5 NP)

30

AUTOMATIC CONTROLLER WITH CENTRAL CONTROL

RAINBIRD (MODEL: ESP-LXD50)

IQ CENTRAL CONTROL: IQ-NCC

STAINLESS STEEL PEDESTAL AND CABINET: LXMMSSPED & ESP-LXMMSS

WIRELESS RAIN SENSOR - RAINBIRD (MODEL: WR2-RFC)

TO BE INSTALLED ON ROOF OF BUILDING IF APPROVED BY

OWNER. RAIN SENSOR SHALL BE INSTALLED PER

MANUFACTURER RECOMMENDATION

RESILIENT WEDGE ISOLATION VALVE - SIZE PER LINE

STAINLESS STEEL BALL VALVE - SIZE PER LINE

MFG.: LEEMCO FITTINGS (MODEL: LBT-XX-SS)

NOTE: REFER TO SHEET L2.00 FOR

ADDITIONAL DETAILS AND GENERAL NOTES

POINT OF CONNECTION IS A 1" RECLAIMED METER. PRESSURE

READING PROVIDED BY CITY IS 40 PSI AFTER METER.

BOOSTER PUMP - DESIGN/BUILD BY IRRIGATION CONTRACTORBP

2" IRRIGATION MAINLINE - SOLVENT WELD PVC (PURPLE PIPE)

ASTM D2241 - CLASS 200 - SDR 21

MASTER VALVE & FLOW SENSOR

MASTER VALVE: RAINBIRD (MODEL: 200-EFB-CP-PRS-D)

FLOW SENSOR: RAINBIRD (MODEL: FS150B) WITH

SENSOR DECODER (SD210TURF)

INSTALL PER MANUFACTURER RECOMMENDATIONS

SURGE PROTECTOR/GROUNDING PLATE.

MFG.: RAINBIRD SENSOR DECODER (MODEL: LSP-1)

INSTALL EVERY 500' OF CONTROL WIRE OR 10 DECODERS, WHICHEVER IS

LESSER

EARTH GROUND RESISTANCE READINGS TO BE 10 OHMS OR LESS.

RESISTANCE READINGS WILL BE REQUIRED TO BE TESTED BY CONTRACTOR

AND A REPORT VERIFYING READINGS HAVE MET SPECIFICATIONS SUBMITTED

TO OWNER PRIOR TO FINAL PAYMENT BEING RELEASED.

MATCHLINE-SEE SHEET L 2.01

00 20' 40'

IRRIGATION PLAN

L2.02

MATCHLINE-SEE SHEET L 2.01

CYCADIA CEMETERY EAST

(PHASE I)

SEPTEMBER 2019

CITY OF

TARPON SPRINGS

00287-011.01

ANDREW HILL, PLA

LA6667073

PROJECT NO:

DATE:

SHEET NO:

LIC. NO.:

DATE

BY DATEDESCRIPTIONNO.

DESIGNED

DRAWN

Q.C.

APPROVED

CJC, JLG

CJC, JLG

CJC

LA 6667073

STATE

OF

A

N

D

R

E

W

D

.

H

I

L

L

CLEARWATER

380 PARK PLACE BLVD, STE 300, CLEARWATER, FL 33759

TEL: (727) 531 - 3505 FAX: (727) 431 - 1777

www.cardno.com Certificate of Authorization No. 29915

09-20-19

NOTE: CONTRACTOR TO COORDINATE AND

OBTAIN ENCROACHMENT PERMIT PRIOR TO

INSTALLING IRRIGATION WITHIN THE

RIGHT OF WAY ALONG BOTH ROADS. NO

CONSTRUCTION MAY COMMENCE PRIOR TO

OBTAINING THE ENCROACHMENT PERMIT

ALONG E. TARPON SPRINGS AVENUE AND E.

JASMINE AVENUE

Page 6: E. JASMINE AVENUE · 9as shown podocarpus macrophylla podocarpus 5 gal. 54" ht. 1905'-0" o.c. mature: 6-7' ht. / 5' wd. liriope muscari big blue lily turf 1 gal.1961'-6" o.c. stenotaphrum

GRASS

3" 4"

MULCH OF

PLANT BED

7"

SCALE:

TRENCH EDGING DETAILN.T.S.

4L 3.00

NOTE: USE TRENCH

DETAIL ON ALL SHRUB

BEDS NEXT TO

GRASSED AREAS.

SCALE:

SHRUB & GROUNDCOVER PLANTING DETAILN.T.S.

2L 3.00

SCALE:

TYPICAL TREE STAKING DETAILN.T.S.

1L 3.00

MULTI-STEM TREE

3"-4" EARTH SAUCER

CROWN SPREAD

OVERALL H

EIG

HT

PREPARED PLANTING SOIL

ANY BURLAP AND WIRE

BASKETS CUT OFF OF THE

TOP 3RD OF BALL

60 DEGREE ANGLE

LODGE POLE AT APPROXIMATELY

ROOTBALL OF CONTAINER GROWN

TREE

HOLD MULCH OFF 3" FROM STEMS,

TRUNKS AND ROOT COLLAR

30 INCH V.I.T CINCH STRAP

DOUBLE KNOTTED AROUND

TRUNK

ARBOR TIE - NYLON/POLYESTER

STRAPPING

3 TO 5 TIMES THE WIDTH

OF THE ROOTBALL

3" MULCH PER PLAN

SHRUBS & GROUNDCOVERS

O.C. SPACING

O

.

C

.

S

P

A

C

I

N

G

BED LINE

BACK OF CURB/

TO BE TRIANGULAR SPACING.

ALL SHRUBS/GROUNDCOVER

18" MIN. SETBACK FOR

SEE PLANT LIST FOR (O.C.) SPACING.

HEIG

HT

OF ROOTBALL

3 TO 5 TIMES WIDTH

MULCH 3" FROM STEMS

3" MULCH LAYER

PREPARED PLANTING SOIL

SPREAD

FERTILIZER TABLETS AS SPECIFIED.

PLACE UNIFORMLY AROUND ROOT

MASS BETWEEN MIDDLE AND

BOTTOM OF ROOT MASS

12"

TILLED AND LOOSENED

NATIVE SOIL BACKFILL

NOTE: CONTRACTOR TO

EXCAVATE A MINIMUM 6-18"

BELOW EXISTING GRADE, TO

REMOVE ALL NON-INDIGENOUS

ASPHALT, CONCRETE, AND

LIMEROCK BASE

NOTE: CONTRACTOR TO

EXCAVATE A MINIMUM 6-18"

BELOW EXISTING GRADE, TO

REMOVE ALL NON-INDIGENOUS

ASPHALT, CONCRETE, AND

LIMEROCK BASE

SCALE:

TREE PROTECTION FENCEN.T.S.

3L 3.00

TILLED AND LOOSENED

NATIVE SOIL BACKFILL

LANDSCAPE NOTES

1. ALL PLANTS SHALL BE FLORIDA #1 OR BETTER. ALL PLANTS SHALL BE TYPICAL OF THEIR SPECIES OR

VARIETY AND SHALL HAVE A NORMAL HABIT OF GROWTH. THEY SHALL BE SOUND, HEALTHY AND VIGOROUS,

WELL-BRANCHED AND DENSELY FOLIATED WHEN IN LEAF. THEY SHALL BE FREE OF DISEASE AND INSECT

PESTS, EGGS OR LARVAE. THEY SHALL HAVE HEALTHY, WELL-DEVELOPED ROOT SYSTEMS. ALL PLANTS

SHALL BE GUARANTEED FOR 1 YEAR AFTER FINAL ACCEPTANCE BY OWNER. HEDGE MATERIAL MUST BE

PLANTED 2.5' TO 3' ON CENTER DEPENDING ON THE SPECIES. ALL REQUIRED TREES MUST BE A MINIMUM OF

8' HIGH, 2" CALIPER AT TIME OF PLANTING. ALL HEDGE MUST BE 24" HIGH AT TIME OF PLANTING AND BE

MAINTAINED AT A MINIMUM OF 3' IN HEIGHT.

2. SUBSTITUTIONS: WHEN PLANTS OF A SPECIFIED KIND OR SIZE ARE NOT AVAILABLE, A REASONABLE

SUBSTITUTION MAY BE MADE UPON REQUEST IN WRITING BY THE LANDSCAPE CONTRACTOR, IF APPROVED

BY THE OWNER.

3. AS PER THESE DRAWINGS AND SPECIFICATIONS, THE "HT." (HEIGHT) OF PROPOSED PLANT MATERIALS,

UNLESS OTHERWISE SPECIFIED, SHALL MEAN THE ACTUAL DISTANCE AS MEASURED FROM THE SOIL STRESS

MARK ON TRUNK OR BASE OF PLANT TO THE TOP ELEVATION OF THE PLANT.

4. WORK UNDER THESE SPECIFICATIONS SHALL CONSIST OF PREPARATION OF PLANTING AREA; FURNISHING

AND PLANTING ALL PROPOSED NEW PLANT MATERIALS SPECIFIED HEREIN AND AS SHOWN ON THE

DRAWINGS, INCLUDING BUT NOT LIMITED TO FINISHED GRADING, FURNISHING TOPSOIL, STAKING,

WATERING, PRUNING, FERTILIZING, MULCHING, AND LAYING SOD; AND MAINTENANCE AND PROTECTION OF

PLANTS UNTIL FINAL ACCEPTANCE BY OWNER.

5. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL PLANTS SHOWN ON THE DRAWINGS, AS SPECIFIED, AND

IN QUANTITIES LISTED ON THE PLANT MATERIALS LIST. IN THE EVENT OF A VARIATION BETWEEN THE PLANT

LIST AND THE ACTUAL NUMBER OF PLANTS SHOWN ON THE PLANTING PLAN, THE PLANTING PLAN SHALL

CONTROL.

6. THE OWNER SHALL HAVE THE RIGHT TO REJECT ANY AND ALL WORK AND MATERIALS WHICH, IN THEIR

OPINION, DO NOT MEET THE REQUIREMENTS OF THE PLANTING PLAN, DETAILS, AND THESE SPECIFICATIONS.

7. THE LANDSCAPE CONTRACTOR SHALL STAKE ALL PLANT MATERIAL LOCATIONS FROM THE PLANTING PLAN

PRIOR TO INSTALLATION FOR APPROVAL BY THE OWNER.

8. ALL PLANTING BED AREAS SHALL BE FINE GRADED BY THE LANDSCAPE CONTRACTOR.

9. THE LANDSCAPE CONTRACTOR SHALL EXAMINE THE SOILS OF ALL PLANTING AREAS PRIOR TO PLANTING FOR

THE SUITABILITY TO SUSTAIN HEALTHY PLANT GROWTH AS CALLED FOR ON THE PLANTING PLAN, DETAILS,

AND THESE SPECIFICATIONS.

10. CONTRACTOR TO FINE GRADE AND ROCK-HOUND ALL TURF AREAS PRIOR TO SEEDING AND/OR SODDING, TO

PROVIDE A SMOOTH AND CONTINUAL SURFACE, FREE OF IRREGULARITIES (BUMPS OR DEPRESSIONS) AND

EXTRANEOUS MATERIAL OR DEBRIS.

11. ALL PROPOSED PLANTING AREAS FOR TREES, PALMS, SHRUBS AND GROUNDCOVERS SHALL BE TOP DRESSED

WITH A MINIMUM OF THREE (3) INCHES OF MINI PINE BARK NUGGETS MULCH, SPREAD UNIFORMLY IN DEPTH

OVER THE PLANTING BEDS AS DELINEATED ON THE PLANS UNLESS OTHERWISE NOTED.

12. MULCH SHALL BE ORGANIC AND SHALL BE SPECIFIED IN PLANT BEDS AND AROUND INDIVIDUAL TREES.

WHEN APPLIED TO TREES, MULCH SHALL NOT BE PLACED ON TOP OF THE ROOT BALL OR BE PLACED AGAINST

THE TRUNK. MULCH SHALL BE APPLIED A MINIMUM OF 12" TO 18" FROM THE TRUNK FOR ANY SIZED TREE.

MATERIALS THAT DO NOT BIODEGRADE SUCH AS ROCK AND SHELLS, ARE NOT DEEMED ACCEPTABLE.

FAILURE TO INSTALL MULCH (AND TYPE OF MULCH) AS PROVIDED IN THE SPECIFICATION ABOVE MAY RESULT

IN A FAILED INSPECTION. SEE HTTP://HORT.IFAS.UFL.EDU/WOODY/OVER-MULCHING.SHTML FOR MORE

INFORMATION.

13. ALL PLANTS, UNLESS OTHERWISE SPECIFIED, SHALL BE NURSERY GROWN STOCK, AND SHALL COMPLY WITH

ALL REQUIRED INSPECTIONS, GRADING STANDARDS, PLANT REGULATIONS AND REQUIREMENTS FOR

MEASUREMENT, BRANCHING AND CULTURAL PRACTICES; AS SET FORTH IN THE FLORIDA DEPARTMENT OF

AGRICULTURE "GRADES AND STANDARDS FOR NURSERY PLANTS", (LATEST EDITION), INCLUDING REVISIONS

AS DETERMINED BY THE STATE PLANT BOARD OF FLORIDA OR TO THE STANDARDS AS GIVEN IN THE LATEST

"AMERICAN STANDARD FOR NURSERY STOCK," AMERICAN NATIONAL STANDARDS INSTITUTE.

14. WHERE PROPOSED TREE LOCATIONS OCCUR UNDER EXISTING OVERHEAD UTILITIES OR CROWD EXISTING

TREES, NOTIFY LANDSCAPE ARCHITECT TO ADJUST TREE LOCATIONS.

15. PRIOR TO MOBILIZATION, THE CONTRACTOR SHALL NOTIFY THE OWNER, IN WRITING, IF HE/SHE BELIEVES

ANY OF THE PLANT MATERIAL IDENTIFIED ON THE PLAN MAY NOT BE SUITABLE FOR THE SITE OR MAY DIE.

SUBSTITUTION REQUESTS WILL BE GRANTED BY THE OWNER PRIOR TO THE START OF CONSTRUCTION

ACTIVITIES. IF NOTIFICATION IS NOT GIVEN TO THE OWNER, ALL PLANTING WHICH FAILS TO GROW (EXCEPT

FOR DEFECTS RESULTING FROM LACK OF ADEQUATE MAINTENANCE AS DETERMINED BY THE OWNER,

NEGLECT OR VANDALISM) SHALL BE REPLACED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE.

16. REFER TO PROJECT MANUAL FOR ADDITIONAL REQUIREMENTS.

17. SITE CONDITIONS ARE BASED UPON SURVEY PROVIDED BY OWNER. CONTRACTOR TO FIELD VERIFY

EXISTING CONDITIONS BY DETAILED INSPECTION PRIOR TO SUBMITTING BID AND BEGINNING

CONSTRUCTION.

18. REFER TO CIVIL DRAWINGS FOR ADDITIONAL REQUIREMENTS.

19. REESTABLISH TURF IN AREAS DISTURBED BY GRADING OR UTILITY TRENCHING IN THE RIGHT-OF-WAY.

20. COORDINATE WORK WITH OTHER SITE-RELATED DEVELOPMENT DRAWINGS.

21. ALL LANDSCAPE MAINTENANCE SHALL BE IN ACCORDANCE WITH TARPON SPRINGS STANDARDS. LANDSCAPE

MAINTENANCE PERIOD BEGINS IMMEDIATELY AFTER THE COMPLETION OF ALL PLANTING OPERATIONS AND

WRITTEN ACCEPTANCE FROM THE OWNER AND/OR OWNER'S REPRESENTATIVE. MAINTAIN TREES, SHRUBS,

LAWN AND OTHER PLANTS AS PER THE SPECIFICATIONS. LANDSCAPE MAINTENANCE IS THE LANDSCAPING

CONTRACTORS RESPONSIBILITY UNTIL FINAL ACCEPTANCE BY THE OWNER.

TREES: 3 - 21 GRAM TABLETS EACH 1/2" OF CALIPER

PALMS: 7 - 21 GRAM TABLETS

1 GALLON CAN: 1 - 21 GRAM TABLET

3 GALLON CAN: 2 - 21 GRAM TABLETS

5 GALLON CAN: 3 - 21 GRAM TABLETS

7 GALLON CAN: 4 - 21 GRAM TABLETS

APPLICATION RATE:

FERTILIZATION NOTES

1. THE LANDSCAPE CONTRACTOR SHALL FURNISH FROM HIS SOURCE A GOOD CLEAN, NATIVE SOIL WHICH

SHALL MEET THE APPROVAL OF THE OWNER OR HIS REPRESENTATIVE. THIS SOIL SHALL BE USED FOR THE

PLANTING MIXTURE AS FOLLOWS:

A. ONE PART HILLARY PEAT PLANTING MIX, TOPSOIL OR APPROVED EQUAL

B. ONE PART NATIVE SOIL

2. SOILS WITHIN PLANTING AREAS MUST BE SUITABLE FOR PROPOSED PLANTED MATERIAL & SOD WITH REGARD

TO: pH, SOIL TEXTURE, SOIL STRUCTURE, AND SEASONAL HIGH WATER TABLE. THE CONTRACTOR SHALL

ANALYZE EXISTING SOILS LOCATED IN PROXIMITY TO PROPOSED PLANT MATERIAL AND BE RESPONSIBLE TO

AMEND THE SOIL TO OBTAIN ESSENTIAL REQUIREMENTS NECESSARY FOR THE ESTABLISHMENT AND GROWTH

OF PLANT LIFE. ALSO, THE CONTRACTOR SHALL EXCAVATE A MINIMUM OF 6-18 INCHES BELOW EXISTING

GRADE, SO AS TO REMOVE ALL NON-INDIGENOUS ASPHALT, CONCRETE & LIMEROCK BASE.

SOIL PLANTING MIXTURE (MIX ONSITE)

SHRUBS AND TREES:

ALL TREES AND SHRUBS SHALL BE FERTILIZED WITH "AGRIFORM"

20-15-5 PLANTING TABLETS AT TIME OF INSTALLATION AND PRIOR

TO COMPLETION OF PIT BACKFILLING. TABLETS SHALL BE PLACED

UNIFORMLY AROUND THE ROOT MASS AT A DEPTH THAT IS

BETWEEN THE MIDDLE AND BOTTOM OF THE ROOT MASS.

GROUNDCOVER AREAS:

ALL GROUNDCOVER AREAS SHALL RECEIVE FERTILIZATION WITH

"OSMOCOTE" TIME RELEASE FERTILIZER AS PER

MANUFACTURER'S SPECIFICATIONS.

TREE PROTECTION NOTES

1. DURING LAND ALTERATION AND CONSTRUCTION ACTIVITIES, DO NOT PLACE SOIL DEPOSITS,

DEBRIS SOLVENTS, MACHINERY CONSTRUCTION MATERIAL OF ANY KIND WITHIN THE DRIP LINE OF

A TREE TO REMAIN.

2. BEFORE CONSTRUCTION STARTS ALL PROTECTED TREES SHALL BE PRUNED AS FOLLOWS UNLESS

OTHERWISE DIRECTED BY THE OWNER OR HIS REPRESENTATIVE: REMOVE ANY DEAD OR

DISEASED TRUNKS OR BRANCHES, AND REMOVE WEAK OR CROSSED BRANCHES. ALL CUTS SHALL

BE MADE SUFFICIENTLY CLOSE TO THE TRUNK OR PARENT LIMB, WITHOUT CUTTING INTO THE

BRANCH COLLAR OR LEAVING A PROTRUDING STUB, SO THAT CLOSURE CAN READILY START. ALL

TRIMMING SHALL BE DONE BY A QUALIFIED TREE SURGEON. PRUNING SHALL BE IN ACCORDANCE

WITH ANSI A-300 PRUNING STANDARDS.

3. ALL ROOTS TO BE REMOVED DURING THE SITE CLEARING SHALL BE SEVERED CLEAN AT THE

PERIMETER OF THE DESIGNATED PROTECTED RADIUS. A 3" LAYER OF MULCH SHALL BE

IMMEDIATELY APPLIED OVER THE SURFACE OF EXPOSED ROOTS OF PROTECTED TREES. A SOIL

AUGER WILL BE USED TO BORE UNDER ROOT SYSTEMS IF UTILITIES ARE TO BE INSTALLED WITHIN

10' OF A PROTECTED TREE.

4. CONTACT JOE SAMNIK (727.786.8128), CERTIFIED ARBORIST, #SO - 0408, TRAQ, EXPERT TREE

CONSULTANT, LLC FOR ANY INFORMATION ON EXISTING TREES, TREE INVENTORY AND

EVALUATIONS PERFORMED.

WHEN THE CRITICAL ROOT ZONE WILL BE DISTURBED, AFFECTED ROOTS MUST BE SEVERED BY CLEAN

PRUNING CUTS AT THE POINT WHERE CONSTRUCTION IMPACTS THE ROOTS. ROOTS CAN BE PRUNED BY

UTILIZING TRENCHING EQUIPMENT DESIGNED FOR THIS PURPOSE OR BY HAND DIGGING A TRENCH AND

PRUNING ROOTS WITH A PRUNING SAW, CHAIN SAW OR OTHER EQUIPMENT DESIGNED FOR TREE

PRUNING. ROOTS LOCATED WITHIN A CRITICAL ROOT ZONE THAT WILL BE IMPACTED BY

CONSTRUCTION MUST BE PRUNED TO A DEPTH OF 18 INCHES BELOW THE EXISTING GRADE OR TO THE

DEPTH OF DISTURBANCE IF LESS THAN 18 INCHES FROM THE EXISTING GRADE. WHEN UNDERGROUND

UTILITY LINES ARE TO BE INSTALLED WITHIN THE CRITICAL ROOT ZONE, THE ROOT PRUNING

REQUIREMENTS MAY BE WAIVED IF THE LINES ARE INSTALLED VIA TUNNELING OR DIRECTIONAL BORING

AS OPPOSED TO OPEN TRENCHING. A LICENSED CERTIFIED ARBORIST SHALL PROVIDE PRUNING.

ROOT PRUNING NOTE:

BE ADVISED THAT THE EXISTING UTILITIES ARE NOT SHOWN ON THE LANDSCAPE PLANS FOR GRAPHIC

CLARITY. CONTRACTOR TO REFERENCE SURVEY AND UTILITY PLANS TO VERIFY THAT NO EXISTING

UTILITY LINES ARE CONFLICTING WITH PROPOSED TREE LOCATIONS. IF THESE UTILITY LINES DO

CONFLICT, CONTACT OWNER'S REPRESENTATIVE IMMEDIATELY PRIOR TO ANY CONSTRUCTION

ACTIVITY.

EXISTING UTILITY NOTE:

FERTILIZER TABLETS AS

SPECIFIED. PLACE

UNIFORMLY AROUND

ROOT MASS BETWEEN

MIDDLE AND BOTTOM OF

ROOT MASS

CYCADIA CEMETERY EAST

(PHASE I)

SEPTEMBER 2019

CITY OF

TARPON SPRINGS

00287-011.01

ANDREW HILL, PLA

LA6667073

PROJECT NO:

DATE:

SHEET NO:

LIC. NO.:

DATE

BY DATEDESCRIPTIONNO.

DESIGNED

DRAWN

Q.C.

APPROVED

CJC, JLG

CJC, JLG

CJC

LA 6667073

STATE

OF

A

N

D

R

E

W

D

.

H

I

L

L

CLEARWATER

380 PARK PLACE BLVD, STE 300, CLEARWATER, FL 33759

TEL: (727) 531 - 3505 FAX: (727) 431 - 1777

www.cardno.com Certificate of Authorization No. 29915

09-20-19

PLANTING DETAILS & NOTES

L3.00

Page 7: E. JASMINE AVENUE · 9as shown podocarpus macrophylla podocarpus 5 gal. 54" ht. 1905'-0" o.c. mature: 6-7' ht. / 5' wd. liriope muscari big blue lily turf 1 gal.1961'-6" o.c. stenotaphrum

POP-UP SPRAY HEAD

SCH. 40 PVC FITTING

ON LATERAL LINE

SCH. 40 PVC STREET ELL

FINISH GRADE

EOP, CURB, WALK OR BEDLINE

POP-UP GEAR ROTOR

SCH. 40 PVC FITTING

SCH. 40 PVC STREET ELL

ON LATERAL LINE

FINISH GRADE

EOP, CURB, WALK OR BEDLINE

4" MULCH LAYER

1/2" INSERT TEE

FINISH GRADE

PVC SUB MAIN

PVC TEE (SxSxT)

3/4" SCH 80 PVC

PVC MAIN LINE

SCH. 40 PVC FITTING

CONTROL WIRES

PVC SCH 80 NIPPLE

3" GRAVEL SUMP

WIRE CONNECTORS

FINISH GRADE

1" REMOTE CONTROL VALVE

STD. RECT. VALVE BOX

1" 200 MESH PRESS. REG. FILTER

NIPPLE

DRIP TUBING

18" MIN.

PVC IPS FLEX PIPE

18" MIN.

PVC IPS FLEX PIPE

STAKE END OF

OF CURB

MARK BACK

CAP END OF SLEEVE

FINISH GRADE

SLEEVE

SLEEVE

PAVEMENT

NOTES:

1. UNLESS OTHERWISE INDICATED, ALL SLEEVES ARE TO

BE PVC SCH 40 AND TWO (2) NOMINAL SIZES LARGER

THAN THE PIPE TO BE SLEEVED. FOR EXAMPLE: THE

SLEEVE FOR A 2" PIPE SHALL BE 3". NO IRRIGATION

SLEEVE SHALL BE SMALLER THAN 2".

2. ALL SLEEVES ARE TO BE INSTALLED WITH A MINIMUM

OF 24" DEPTH OF COVER.

3. ALL SLEEVES TO EXTEND A MINIMUM OF 24" BEYOND

THE EDGE OF PAVEMENT (WHEN POSSIBLE).

4. IDENTIFY ALL SLEEVES LOCATIONS BY STAKING THE

SLEEVE ENDS WITH COLOR CODED BLUE REBAR AND /

OR MARKING THE BACK OF CURB (OR

PAVEMENT)...COORDINATE WITH GENERAL

CONTRACTOR FOR PREFERRED METHOD.

PROVIDE 12" MIN. SPACE BETWEEN ALL

SPRINKLER HEADS AND ANY WALL OR STRUCTURE

BLDG

PAVEMENT

SIDEWALK

E.O.P.

LIGHTPOLE

B.O.C.

ROADWAY

20 GPM MAX.

40 GPM MAX.

JUMBO VALVE BOX

STANDARD VALVE BOX

REMOTE CONTROL

1" FILTER

PVC SCH 80 90 TxT ELL

PVC SCH 80 TOE NIPPLE

PVC SCH 80 MALE ADP.

PVC MAIN LINE

SCH. 40 PVC FITTING

3" GRAVEL SUMP

WIRE CONNECTORS

FINISH GRADE

1.5" REMOTE CONTROL VALVE

STD. RECT. VALVE BOX

(2) 1" 200 MESH PRESS. REG. FILTER

PVC SCH 80 90 TxT ELL

PVC SCH 80 TOE NIPPLE

PVC SCH 80 MALE ADP.

VALVE I.D. TAGVALVE I.D. TAG

3" GRAVEL SUMPPVC MAIN LINE

VALVE PIT

10" ROUND

FINISH GRADE

GATE VALVE

MECH. JOINT

10" PVC SLEEVE

W/ LANDSCAPE FABRIC

CONTROL WIRES

PVC SCH 80 NIPPLE

W/ LANDSCAPE FABRIC

SEE PLAN

1/2-INCH COMPRESSION

PLANT MATERIAL

VARIES

SEE PLAN

VARIES

NOTE:

LOCATE OUTLET OF 1/4"

DISTRIBUTION TUBING ADJACENT

TO ROOT BALL BELOW GRAVEL.

1/2" DIA. BLACK STRIPE TUBING

1/4" DIA. DISTRIBUTION TUBING

TO PLANT ROOTBALL, BELOW

GRAVEL - ON GRADE

PRESSURE-COMPENSATING

EMITTER ON TUBING: RAIN

BIRD BLACK STRIPE TUBING

STAKE TUBING EVERY 3' L.F.

EMITTER (SEE EMITTER SIZING

SCHEDULE & IRRIGATION NOTES

FOR EMITTER SIZE & QTY

SCALE:

20 GPM DRIP ZONE CONTROL VALVEN.T.S.

1 L 3.01

SCALE:

IRRIGATION SLEEVING DETAILN.T.S.

13 L 3.01

NOTE: PROVIDE

12" MIN. SPACE

BETWEEN ALL

DRIPLINES AND

ANY WALL OR

STRUCTURE

SCALE:

PVC - DRIP CONNECTIONN.T.S.

5 L 3.01

SCALE:

GATE VALVE DETAILN.T.S.

10 L 3.01SCALE:

TURF SPRAY HEADN.T.S.

8 L 3.01 SCALE:

TURF ROTOR HEADN.T.S.

9 L 3.01

SCALE:

"AS BUILT" TYPICALN.T.S.

12 L 3.01

SCALE:

BLACK STRIPE TUBINGN.T.S.

6 L 3.01

SCALE:

40 GPM DRIP ZONE CONTROL VALVEN.T.S.

2 L 3.01 SCALE:

DRIP ZONE VALVE - PLAN VIEWN.T.S.

3 L 3.01

FINISH GRADE.

VALVE BOX.

EXTENSION (LENGTH AS

REQUIRED - 24" MIN)

12-14 AWG TWO WIRE

CONTROL WIRE

SCALE:

WIRE SPLICEN.T.S.

7 L 3.01

WATER FLOW

TURF OR MULCH,

REFER TO

LANDSCAPE

MATERIAL SCHEDULE

FOR MORE INFO

3/8" PEA GRAVEL, 4" DEEP - LINE

BOX w/ FILTER FABRIC

STANDARD RECTANGULAR

VALVE BOX w/ OVERLAPPING

LID AND LOCKING BOLT -

SET BOX SO THAT TOP IS

FLUSH w/ TURF FINISH

GRADE OR MULCH

MIN. 10x

PIPE DIAMETER

24

"M

IN

.

MIN. 5x

PIPE DIAMETER

MASTER VALVE PER

IRRIGATION MATERIAL

SCHEDULE

PVC MAIN LINE, SIZE PER PLAN OR

PIPE SIZING SCHEDULE

NOTE:

INLET PIPE LENGTH OF SENSOR MUST BE MIN. 10X

PIPE DIAMETER STRAIGHT, CLEAN RUN OF PIPE, NO

FITTINGS OR TURNS. OUTLET PIPE LENGTH OF

SENSOR MUST BE MIN. 5X PIPE DIAMETER OF

STRAIGHT, CLEAN RUN OF PIPE, NOT FITTINGS OR

TURNS.

FINISH GRADE

10" ROUND VALVE BOX w/

OVERLAPPING LID AND

LOCKING BOLT - SET BOX SO

THAT TOP IS FLUSH w/ TURF

FINISH GRADE OR LAYER OF

ROCK/BARK MULCH

I

N

L

E

T

O

U

T

L

E

T

FLOW SENSOR W/ PE 39

COMMUNICATION CABLE OR

TWO WIRE CABLE TO

IRRIGATION CONTROLLER

SCALE:

MASTER VALVE AND FLOW SENSORN.T.S.

4 L 3.01

SCALE:

SURGE PROTECTORN.T.S.

11 L 3.01

VALVE

NOTES:

1. SURGE DECODER SHOULD BE INSTALLED EVERY 500-FEET.

2. SURGE DECODER TO BE INSTALLED AT END OF WIRE RUN

THAT TERMINATES IN THE FIELD (STAR CONFIGURATION).

FINISH GRADE OR TOP OF MULCH

VALVE BOX WITH COVER:

TO GROUNDING PLATE: 10 OHMS OR LESS.

REFER TO TYPICAL GROUNDING PLATE DETAIL

GREEN/YELLOW WIRE FROM SURGE PROTECTOR

TO GROUNDING PLATE (1 OF 2)

DB SERIES WIRE CONNECTOR:

3M DBY/DBR-6

LINE SURGE PROTECTOR

TWO-WIRE CABLE TO NEXT DEVICE (FIELD

DECODER, SENSOR DECODER, LINE SURGE

PROTECTOR OR CONTROLLER)

COMMUNICATION WIRE TO NEXT DEVICE (FIELD

DECODER, SENSOR DECODER, LINE SURGE

PROTECTOR OR CONTROLLER)

3-INCH MINIMUM DEPTH OF 3/4-INCH WASHED

GRAVEL

BRICK (1 OF 2)

BLUE WIRE FROM SURGE PROTECTOR TO DB

SERIES WIRE CONNECTOR

PROVIDE 12" MIN. SPACE BETWEEN ALL

SPRINKLER HEADS AND ANY WALL OR STRUCTURE

PREFORMED SUPER

SERVISEAL WATERPROOF

WIRE SPLICE KIT

3M DBY/DBR-6 CONNECTORS

(SPLICE ALL WIRE PAIRS)

CYCADIA CEMETERY EAST

(PHASE I)

SEPTEMBER 2019

CITY OF

TARPON SPRINGS

00287-011.01

ANDREW HILL, PLA

LA6667073

PROJECT NO:

DATE:

SHEET NO:

LIC. NO.:

DATE

BY DATEDESCRIPTIONNO.

DESIGNED

DRAWN

Q.C.

APPROVED

CJC, JLG

CJC, JLG

CJC

LA 6667073

STATE

OF

A

N

D

R

E

W

D

.

H

I

L

L

CLEARWATER

380 PARK PLACE BLVD, STE 300, CLEARWATER, FL 33759

TEL: (727) 531 - 3505 FAX: (727) 431 - 1777

www.cardno.com Certificate of Authorization No. 29915

09-20-19

IRRIGATION DETAILS

L3.01

Page 8: E. JASMINE AVENUE · 9as shown podocarpus macrophylla podocarpus 5 gal. 54" ht. 1905'-0" o.c. mature: 6-7' ht. / 5' wd. liriope muscari big blue lily turf 1 gal.1961'-6" o.c. stenotaphrum

PVC SWEEP ELL

(1 1/2" OR LARGER)

6 AWG SOLID BARE

COPPER WIRES

GROUND PLATE

EARTH CONTACT

MATERIAL

ELECTRODE

SPHERE OF

INFLUENCE

BOUNDARIES *

COPPER GROUND PLATE

(4" X 96" X .0625")

* DO NOT INSTALL ANY OTHER WIRES OR CABLE

WITHIN THE SPHERE OF INFLUENCE

CONTROLLER

CONCRETE PAD

#6 AWG SOLID

BARE COPPER WIRE

#6 AWG SOLID

BARE COPPER WIRE

CONTROLLER

CONCRETE PAD

MIM. 8' FROM CONT.

MINIMUM ACCEPTABLE RESISTANEC TO GROUND IS 25 OHMS.

USE ADDITIONAL GROUND PLATES OR GROUND RODS AS NEEDED.

SCALE:

CONTROLLER GROUNDINGN.T.S.

2 L 3.02

TOP VIEW

SIDE VIEW

GROUND PLATE

GROUND PLATE

L

3L

3W

W

for the latest rev. go to

http://www.asic.org/design_guides.htm

EARTH CONTACT

MATERIAL

GROUND PLATE

6 AWG SOLID BARE

COPPER WIRES

30" MIN. *

VALVE BOX

COPPER GROUND PLATE

(4" X 96" X .0625")

12"

8'

8'

#6 AWG SOLID

BARE COPPER WIRE ELECTRODE

SPHERE OF

INFLUENCE

BOUNDARIES

DO NOT INSTALL ANY OTHER WIRES OR CABLE

WITHIN THE SPHERE OF INFLUENCE

* OR BELOW FROSTLINE, WHICHEVER IS DEEPER

SIDE VIEW

DO NOT INSTALL ANY OTHER WIRES OR CABLE

WITHIN THE SPHERE OF INFLUENCE

NOTE: INSTALL EVERY 500' OF CONTROL WIRE OR 10 DECODERS, WHICHEVER IS LESS.

EARTH GROUND RESISTANCE READINGS TO BE 10 OHMS OR LESS. RESISTANCE

READINGS WILL BE REQUIRED TO BE TESTED BY CONTRACTOR AND A REPORT SUBMITTED

TO CARDNO PRIOR TO FINAL PAYMENT BEING RELEASE.

AMERICAN SOCIETY OF IRRIGATION CONSULTANTS COPYRIGHT 2001

SCALE:

TYPICAL GROUNDING PLATEAND SPHERES OF INFLUENCE

N.T.S.

3 L 3.02

BRICK OR CONC. BLOCK

CLASS 200 MAINLINE

STANDARD RECTANGULAR VALVE BOX

FINISH GRADE

NOTES:

1. PVC PIPE & FITTINGS UPSTREAM OF THE

ISOLATION VALE TO BE THE SAME AS

SIZE THE MAINLINE.

2. ISOLATION VALVE SAME SIZE AS REMOTE

CONTROL VALVE.

3. ONE VALVE PER STANDARD

RECTANGULAR VALVE BOX

DRAIN ROCK WITH LANDSCAPE FABRIC.

MIN. 3" DEEP AND 2" BELOW BOTTOM

OF PIPE

NOTES:

1. MAXIMUM LENGTH OF SECONDARY WIRE PATH (14 AWG)

FROM FIELD DECODER TO SOLENOID IS 450 FEET.

2. PLACE 3 FEET OF EXTRA WIRE IN EVERY VALVE BOX FOR

EASIER SERVICING.

3. ALL WIRE CONNECTIONS SPLICED WITH DIRECT BURY SPLICE

KIT (3M DBY/DBR-6) CONNECTORS.

COMMUNICATION

WIRE TO NEXT

DEVICE (FIELD

DECODER, SENSOR

DECODER, LINE

SURGE PROTECTOR

OR CONTROLLER)

TWO-WIRE CABLE TO

NEXT DEVICE (FIELD

DECODER, SENSOR

DECODER, LINE SURGE

PROTECTOR OR

CONTROLLER)

FIELD DECODER

DB SERIES WIRE

CONNECTOR:

3M DBY/DBR-6

(1 OF 4)

SOLENOID WIRE (1 OF 2)

SCALE:

VALVE AND DECODER DETAILN.T.S.

1L 3.02

1. CONTRACTOR TO VERIFY WITH OWNER AND UTILITY COMPANIES THE LOCATIONS OF ALL UTILITIES

PRIOR TO CONSTRUCTION AND TO DETERMINE IN THE FIELD THE ACTUAL LOCATIONS AND

ELEVATIONS OF ALL EXISTING UTILITIES WHETHER SHOWN ON THE PLAN OR NOT. THE

CONTRACTOR SHALL CALL UTILITY PROTECTION SERVICE 72 HOURS PRIOR TO CONSTRUCTION.

2. CONTRACTOR TO REPORT ALL DAMAGES TO EXISTING CONDITIONS OR INCONSISTENCIES WITH

PLANS TO LANDSCAPE ARCHITECT.

3. CONTRACTOR SHALL EXAMINE FINISH SURFACE, GRADES, TOPSOIL QUALITY AND DEPTH. DO NOT

START ANY WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. VERIFY LIMITS

OF WORK BEFORE STARTING.

4. CONTRACTOR SHALL COORDINATE IRRIGATION INSTALLATION WITH INSTALLATION OF

LANDSCAPING, WALL CONSTRUCTION AND DRAINAGE SYSTEMS. IRRIGATION CONTRACTOR WILL

BE RESPONSIBLE FOR COORDINATION WITH OTHER SUBCONTRACTORS FOR INSTALLATION OF

UNDERGROUND SLEEVING.

5. ALL PRODUCTS SHALL BE INSTALLED PER THE MANUFACTURER'S RECOMMENDATIONS AND

ACCORDING TO TO LOCAL BUILDING, ELECTRICAL, AND PLUMBING CODES.

6. IF REQUIRED, THE IRRIGATION CONTRACTOR SHALL PROVIDE THE NECESSARY "RIGHT OF WAY"

ENCROACHMENT PERMITS.

7. PRIOR TO BACKFILLING TRENCHES CONTACT LANDSCAPE ARCHITECT TO VERIFY WIRE PATH

ROUTING, CONTROLLER WIRE AND SPLICING CONNECTIONS.

8. LAYOUT OF THE SYSTEM AS SHOWN ON DRAWINGS IS DIAGRAMMATIC. IRRIGATION LINES SHOWN

WITHIN PAVED AREAS ARE FOR GRAPHIC CLARITY ONLY. IRRIGATION HEADS AND PIPES ARE TO BE

PLACED WITHIN LANDSCAPED AREAS WITH THEIR LOCATIONS MODIFIED AS REQUIRED TO AVOID

PLANT MATERIALS, UTILITIES AND OTHER OBSTRUCTIONS.

9. IRRIGATION CONTRACTOR SHALL COMPLY WITH PIPE SIZES AS INDICATED.

10. PIPE UP TO 1-1/2" DIAMETER MAY BE PULLED WITH A VIBRATORY PLOW EQUAL TO A DITCH WITCH

255. PIPING FROM 2" T0 2-1/2" DIAMETER SHALL BE PULLED WITH A MACHINE LARGER OR EQUAL

TO A DITCH WITCH R-40. TRENCH ALL PIPE OVER 2-1/2" DIAMETER. CONTRACTOR HAS THE OPTION

TO TRENCH ALL PIPE.

11. THE MAINLINE IS TO BE INSTALLED WITH A MINIMUM OF 24" DEPTH OF COVER. ALL LATERAL LINES

ARE TO BE INSTALLED WITH A MINIMUM OF 12" DEPTH OF COVER.

12. THE IRRIGATION DISTRIBUTION MAINLINE SHALL BE INSTALLED PER CITY OF TARPON SPRINGS

WATER STANDARDS.

13. CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING ALL SLEEVING FOR THE PROJECT. ALL

SLEEVES ARE TO BE PVC SCH 40 AND TWO (2) NOMINAL SIZES LARGER THAN THE PIPE TO BE

SLEEVED. FOR EXAMPLE: THE SLEEVE FOR A 2" PIPE SHALL BE 3". NO IRRIGATION SLEEVE SHALL

BE SMALLER THAN 2".

14. WHEREVER PRACTICAL, INSTALL VALVES IN MULCHED BEDS AND/OR OUT OF HIGH TRAFFIC

AREAS. IF INSTALLED IN TURF AREA, VALVE BOX TO BE A MINIMUM OF 48" FROM BED EDGE. ONE

VALVE PER VALVE BOX. ALL VALVES , FLUSH VALVES AND WIRE SPLICES SHALL BE INSTALLED IN

RAIN BIRD WIDE FLANGED, STRUCTURAL FOAM "PLASTIC" VALVES BOXES WITH LIDS AS FOLLOWS:

REMOTE CONTROL VALVES #VB-STD, 12" STD. RECT. BOX

ISOLATION GATE VALVES #VB-10RND, 10" ROUND BOX

WIRE SPLICES #VB-10RND, 10" ROUND BOX

DRIP ZONE VALVE / FILTER ASSY #VB-SPR, SUPER JUMBO RECT. BOX

15. LOCATE VALVE MANIFOLDS IN CLOSE PROXIMITY FOR EASE OF MAINTENANCE, BUT NOT CLOSER

THAN 4'-0" BETWEEN VALVE BOXES.

16. ALL POP-UP SPRINKLER HEADS AND ROTORS SHALL BE INSTALLED LEVEL AND FLUSH TO GRADE.

17. LOCATION OF ALL SPRINKLER HEADS SHALL BE SITE ADJUSTED TO MINIMIZE WATER OVERTHROW

ONTO BUILDING SURFACES AND WALKWAYS. THROTTLE VALVES ON SPRAY ZONES AS REQUIRED

TO PREVENT FOGGING. USE LOW TRAJECTORY NOZZLES WHENEVER POSSIBLE. ALL SPRINKLER

HEADS SHALL BE INSTALLED PERPENDICULAR TO FINISH GRADES EXCEPT AS OTHERWISE

INDICATED.

18. PROTECT IRRIGATION CONTROL EQUIPMENT UNIT FROM DAMAGE AFTER INSTALLATION AND UNTIL

FINAL ACCEPTANCE. THE UNIT SHALL BE IN BRAND NEW CONDITION WHEN FULL OPERATION OF

THE SYSTEM IS TURNED OVER TO THE OWNER AFTER FINAL ACCEPTANCE. THE CONTRACTOR

SHALL, AT THEIR OWN EXPENSE, REPLACE ALL OR PART OF THE UNIT THAT IS DAMAGED AND

UNACCEPTABLE TO THE OWNER.

19. INSTALL DRIP TUBING AT GRADE AND COVER WITH MULCH. TYPICAL SPACING FOR DRIP TUBING IS

18" TO 24" ON CENTER. SPACING TO BE DETERMINED BY SOIL TYPE. ANCHOR TUBING EVERY 7'

WITH 8" LONG WIRE TUBING STAKES.INSTALL FLUSH VALVE ASSEMBLIES AT ALL TUBING "DEAD

ENDS".

20. EXACT CONTROLLER LOCATION(S) SHALL BE COORDINATED WITH AN OWNER'S REPRESENTATIVE

PRIOR TO INSTALLATION. UNLESS OTHERWISE STATED, THE GENERAL CONTRACTOR SHALL

PROVIDE 110 VOLT POWER TO THE CONTROLLER LOCATION(S). THE IRRIGATION CONTRACTOR IS

RESPONSIBLE FOR THE CONNECTION FROM THE POWER SOURCE TO THE CONTROLLER(S).

INSTALL LEVEL AND PLUMB ON COMPACTED SUBSOIL AND BASE ROCK AS SHOWN ON DRAWINGS.

21. IRRIGATION CONTRACTOR SHALL PROVIDE POWER AND WATER FOR ALL LANDSCAPE ELEMENTS TO

PROVIDE AN OPERATING IRRIGATION SYSTEM, INCLUDING CONTROLLER. IRRIGATION

CONTRACTOR TO PROVIDE AND INSTALL ELECTRICAL CONDUITS AND WIRING TO PROVIDE POWER

FROM ELECTRICAL BRANCH PANEL TO THE IRRIGATION CONTROL EQUIPMENT UNIT, COORDINATE

WITH LANDSCAPE CONTRACTOR. IRRIGATION CONTRACTOR WILL BE RESPONSIBLE TO

COORDINATE WITH AN ELECTRICIAN AS NEEDED.

22. AT EACH IRRIGATION CONTROLLER, INSTALL A "SECONDARY SURGE ARRESTER" TO THE INCOMING

(120 VOLT) POWER SUPPLY (INTERMATIC #AG2401 OR EQUAL).

23. AT EACH IRRIGATION CONTROLLER, INSTALL AN "EARTH GROUND GRID" WITH A MINIMUM OF TWO

(2) 4" X 96" GROUNDING PLATES. TEST THE RESISTANCE TO EARTH PER NFPA STANDARD #780. A

ACCEPTABLE EARTH GROUND SHOULD HAVE 10 OHMS OR LESS RESISTANCE. USE MORE PLATES OR

GROUNDING RODS AS NEEDED TO ACHIEVE THE DESIRED RESISTANCE READING.

24. THE WIRELESS RAIN SHUTOFF DEVICE SHALL BE INSTALLED TO MEET LOCAL CODES AND/OR

MINIMUM MANUFACTURER'S RECOMMENDATIONS. OBSTRUCTIONS, VANDALISM AND EASE OF

SERVICE SHALL BE CONSIDERED IN LOCATING THE DEVICE. DO NOT LOCATE IN AN AREA

SHELTERED FROM RAIN.

25. THE IRRIGATION CONTRACTOR SHALL PREPARE AN AS-BUILT DRAWING ON REPRODUCIBLE PAPER

DETAILING THE ACTUAL INSTALLATION OF THE IRRIGATION SYSTEM. THE AS-BUILT DRAWINGS

SHALL LOCATE ALL MAIN LINE PIPING, CONTROL WIRES, WIRE SPLICES, SLEEVES AND VALVES BY

SHOWING EXACT MEASUREMENTS FROM PERMANENT FEATURES (BUILDINGS, EDGE OF PAVEMENT,

POWER POLES, FIRE HYDRANTS, ETC.). INCLUDE DEPTH OF COVER ON MAINLINE AND SLEEVES.

FINAL APPROVAL WILL NOT BE GIVEN WITHOUT A SUBMITTED AND APPROVED AS-BUILT.

26. IRRIGATION CONTRACTOR SHALL PROVIDE A COLOR CODED MAP OF THE AREA SERVED BY EACH

CONTROLLER, SEALED IN PLASTIC OR LAMINATED, AND PLACE IT IN EACH CONTROLLER BOX UPON

FINAL ACCEPTANCE.

27. ANY OTHER EQUIPMENT REQUIRED THAT IS NOT OTHER WISE DETAILED OR SPECIFIED SHALL BE

INSTALLED AS PER MANUFACTURER'S RECOMMENDATIONS AND LOCAL CODE IN ORDER TO

PROVIDE A COMPLETE AND OPERABLE SYSTEM.

28. ALL IRRIGATION SYSTEMS SHALL BE OPERATED AND MAINTAINED IN ACCORDANCE TO THE

PINELLAS COUNTY STANDARDS.

29. INSTALL TRACING WIRE OVER ALL MAINLINE PIPE AND CONTROLLER WIRE (INCLUDING) WIRE

WHICH IS NOT INSTALLED IN TRENCH WITH PIPE.

30. CONTRACTOR TO PROVIDE OWNER WITH KEYS AND HOSE SWIVELS FOR EACH QUICK COUPLER

VALVE.

31. CONTRACTOR SHALL OBTAIN WRITTEN APPROVAL FOR ALL PRODUCT SUBSTITUTIONS BY THE

LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. PRODUCTS, MANUFACTURERS, AND MODELS

NOT IN COMPLIANCE WITH DRAWINGS AND SPECIFICATIONS MAY BE REJECTED BY THE LANDSCAPE

ARCHITECT WITHOUT PRIOR WRITTEN APPROVAL. AT NO COST TO THE OWNER THESE ITEMS MAY

BE REQUIRED TO BE REPLACED WITH PRODUCTS THAT ARE IN COMPLIANCE WITH THE

MANUFACTURERS AND MODELS ON THE IRRIGATION PLAN.

32. PROVIDE AND INSTALL CONDUIT SWEEPS AND STRAIGHT SECTIONS FROM IRRIGATION TRENCHES

TO THE CONTROLLER. ROUTE CONTROL WIRE THROUGH CONDUITS INTO CONTROLLER CABINET.

NEATLY CONNECT WIRES TO TERMINAL STRIPS PROVIDED IN THE CONTROLLER CABINET.

34. ALL WIRE SPLICES OR CONNECTIONS SHALL BE MADE WITH APPROVED WATERPROOF WIRE

CONNECTIONS AND BE IN A VALVE OR SPLICE BOX.

35. IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR ADJUSTING THE RUN TIMES SO THAT TURF

AND PLANTS ARE NOT OVER-WATERED, AND SHALL BE RESPONSIBLE FOR KEEPING THE SITE FREE

OF STANDING WATER.

36. SET AND UTILIZE CONTROLLER TO WATER NEW PLANTINGS FOR THE DURATION OF THE PROJECT

UNTIL FINAL ACCEPTANCE.

37. IRRIGATION CONTRACTOR WILL ARRANGE INSPECTIONS REQUIRED BY LOCAL AGENCIES &

ORDINANCES DURING THE COURSE OF CONSTRUCTION AS REQUIRED. ALL PRODUCTS, WIRING

AND BACKFLOW PREVENTER TO BE INSTALLED IN ACCORDANCE WITH LOCAL AND STATE PLUMBING

CODES

38. ALL CONTROL WIRING DOWNSTREAM OF THE CONTROLLER IS TO BE 2-WIRE, UL APPROVED DIRECT

BURY.

39. THE INSTALLING CONTRACTOR MUST HOLD A CURRENT, VALID FLORIDA IRRIGATION

CONTRACTOR'S LICENSE.

40. THE DESIGN IS BASED ON SITE INFORMATION AND /OR DRAWING SUPPLIED WITH THE DESIGN

CRITERIA BEING SET (AREA TO BE IRRIGATED, EQUIPMENT MANUFACTURER AND MODEL TO BE

USED, WATER SOURCE INFORMATION. ELECTRICAL POWER AVAILABILITY, ETC...) CARDNO BEARS

NO RESPONSIBILITY OR LIABILITY FOR ANY ERRORS IN DESIGN OR INSTALLATION THAT ARISE DUE

TO INACCURACIES IN THE ABOVE REFERENCED INFORMATION SUPPLIED TO CARDNO IN RELATION

TO THIS PROJECT, UNLESS OTHERWISE NOTED.

REMOTE CONTROL VALVE WITH 18"

COIL OF WIRE & MALE REDUCER

CENTERED IN OPENING

PVC SCH 80 90 TxT ELL

PVC SCH 80 TOE NIPPLE

VALVE ID TAG

PVC SCH 80 NIPPLE

PVC SCH 40 FITTING

TOP VIEW

IRRIGATION NOTES

CYCADIA CEMETERY EAST

(PHASE I)

SEPTEMBER 2019

CITY OF

TARPON SPRINGS

00287-011.01

ANDREW HILL, PLA

LA6667073

PROJECT NO:

DATE:

SHEET NO:

LIC. NO.:

DATE

BY DATEDESCRIPTIONNO.

DESIGNED

DRAWN

Q.C.

APPROVED

CJC, JLG

CJC, JLG

CJC

LA 6667073

STATE

OF

A

N

D

R

E

W

D

.

H

I

L

L

CLEARWATER

380 PARK PLACE BLVD, STE 300, CLEARWATER, FL 33759

TEL: (727) 531 - 3505 FAX: (727) 431 - 1777

www.cardno.com Certificate of Authorization No. 29915

09-20-19

IRRIGATION DETAILS & NOTES

L3.02