e. jasmine avenue · 9as shown podocarpus macrophylla podocarpus 5 gal. 54" ht....
TRANSCRIPT
1. CONTRACTOR IS REQUIRED TO PERFORM MINOR CLEARING AND GRUBBING SERVICES FOR ENTIRE SITE PRIOR TO INSTALLING PLANT MATERIAL.
THIS INCLUDES BUT IS NOT LIMITED TO REMOVAL OF WEEDS, TRASH, AND SCRUB LIKE MATERIAL. IT IS POSSIBLE THIS MAY INCLUDE SOME FINE
GRADING SERVICES TO ASSURE NO HOLES OR TRIPPING HAZARDS ARE PRESENT. CONTRACTOR SHOULD INCLUDE THIS IN BID PRICE.
2. CONTRACTOR SHALL NOTIFY CARDNO IMMEDIATELY IF EXISTING TREES SHOWN ON THIS PLAN AS REMAINING DO NOT EXIST. ADDITIONAL PLANT
MATERIAL MAY BE REQUIRED TO ACCOUNT FOR MISSING TREES.
3. ALL EXISTING PALMS SLATED TO REMAIN SHALL BE CLEANED UP AND DEBOOTED UP TO A REASONABLE HEIGHT APPROPRIATE TO OVERALL
HEIGHT. ALL VINES ON EXISTING TREES SHALL BE REMOVED.
4. AREAS OF THE LAWN MAY CONTAIN CATCH BASINS AND AREA DRAINS. CONTRACTOR SHALL USE BEST JUDGEMENT TO FINE GRADE AROUND
CATCH BASINS AND OTHER APPURTENANCES TO MINIMIZE EROSION AND MAINTAIN AESTHETIC VALUE. TREES LOCATED IN DRAINAGE WAYS
SHALL BE FIELD ADJUSTED TO PLACE TREES OUTSIDE OF DRAINAGE WAY. CONTACT LANDSCAPE ARCHITECT WITH ANY DISCREPANCIES.
5. CONTRACTOR TO FLAG ALL PROPERTY LINES, EASEMENT LINES, ETC. TO INSTALL PLANTING AND IRRIGATION AS PER PLANS. CONTRACTOR TO
CONTACT OWNER AND LANDSCAPE ARCHITECT PRIOR TO INSTALLATION IF ANY LOCATIONS ARE UNCLEAR
GENERAL LANDSCAPE NOTES
MISCELLANEOUSITEM SIZE COMMENTS
GROUNDCOVERS/SODITEM SIZE QUANTITY SPACING
LANDSCAPE PLANT MATERIAL SCHEDULETREESITEM SIZE QUANTITY SPACING
SHRUBS & ACCENTSITEM SIZE QUANTITY SPACING
SYMBOL
EXISTING TREES TO REMAIN, EVERGREEN & DECIDUOUS
CONTRACTOR TO PROTECT WITHIN DRIP LINES
SEE TREE PROTECTION
& DEMOLITION PLANS
TAXODIUM DISTICHUM
BALD CYPRESS
1.5" CAL.
6' HT.
7 AS SHOWN
QUERCUS VIRGINIANA
LIVE OAK
1.5" CAL.
6' HT.
10 AS SHOWN
ULMUS AMERICANA V. FLORIDANA
FLORIDA ELM
1.5" CAL.
6' HT.
9 AS SHOWN
PODOCARPUS MACROPHYLLA
PODOCARPUS
5 GAL.
54" HT.
190 5'-0" O.C.
MATURE: 6-7' HT. / 5' WD.
LIRIOPE MUSCARI
BIG BLUE LILY TURF
1 GAL. 196 1'-6" O.C.
STENOTAPHRUM SECUNDATUM 'SAPPHIRE'
ST. AUGUSTINE SAPPHIRE
SOD94,000 SF
LANDSCAPE ORDINANCE REQUIREMENTS:
MINIMUM PLANTING REQUIREMENT
SITE AREA: 125,670 SF (DOES NOT INCLUDE
WETLAND AREA OR DETENTION POND)
MINIMUM REQUIRED TREES: 71 TREES (8 FOR FIRST 15,000SF
AND 1 FOR EVERY 2,000SF IN EXCESS
OF THAT)
EXISTING TREES RETAINED: 43 TREES
PROPOSED TREES: 44 TREES
TOTAL TREES: 87 TREES
VUA REQUIREMENTS
PROPOSED PARKING SPACES: 43 SPACES
REQUIRED INTERIOR LANDSCAPE AREA:800 SF
PROPOSED INTERIOR LANDSCAPE AREA:2,245 SF
REQUIRED TREES:8 TREES
PROPOSED TREES: 8 TREES (6 PROPOSED AND 2 EXISTING)
DETENTION POND REQUIREMENTS
TOTAL POND AREA FROM T.O.B.: 7,030 SF
20% OF TOTAL AREA: 1,406 SF
REQUIRED TREES:5 (1 PER 300 SF OF THE
CALCULATED 20% AREA)
PROPOSED TREES:5
EAST BUFFER REQUIREMENTS
WIDTH: 8 FT
LENGTH: 330 LF
REQUIRED TREES: 13 TREES (1 PER 25 LF)
PROPOSED TREES: 13 TREES
REQUIRED SHRUBS: 1 HEDGE ROW
PROPOSED SHRUBS:1 HEDGE ROW
NUMBER INDICATED ONHATCH THROUGHOUTDRAWING REFLECTS THENUMBER OF PLANTS IN THATPARTICULAR AREA
MULCH: ALL SHRUB BEDS SHALL CONTAIN A 3" LAYER OF SHREDDED CYPRESS MULCH.
CONTRACTOR TO PLACE MIN. 4' DIAMETER CYPRESS MULCH CIRCLE AROUND ALL TREES IN SOD (TYP.)
COMMENTS
ILEX VOMITORIA
YAUPON HOLLY
5 GAL.
54" HT.
14 5'-0" O.C.
MATURE: 6-7' HT. / 5' WD.
ACACIA FARNESIANA
SWEET ACACIA
1.5" CAL.
6' HT.
15 AS SHOWN
MAGNOLIA GRANDIFLORA
SOUTHERN MAGNOLIA
1.5" CAL.
6' HT.
3 AS SHOWN
ILEX VOMITORIA 'SCHILLINGS'
SHILLINGS HOLLY
3 GAL.
18" GAL.
41 3'-0" O.C.
12WA
TE
R
ME
TE
R
32
1
32
1
32
1
32
1
32
1
654
32
1
654
32
1
54
2
1
654
2
1
654
2
654
2
654
32
1
6
54
32
1
6
54
32
1
3
3
654
32
6
54
6
54
32
1
6
54
32
1
4
32
1
4
32
1
6
54
32
1
6
54
32
1
54
32
1
32
1
6
54
32
1
6
54
32
1
6
54
32
1
654
32
1
6
54
32
1
6
54
3
2
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
6
32
1
32
1
32
1
32
1
6
54
54
32
1
32
1
3
2
1
3
2
1
32
1
6
54
32
1
6
54
32
1
6
54
3
2
1
6
54
3
2
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
6
5
32
1
6
54
32
1
654
32
1
32
1
32
1
32
1
32
1
3
32
1
3
54
3
3
3
3
3
3 1
32
1
6
54
3
2
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
3
2
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
5
2
1
1
1
32
1
32
1
WA
TE
R
ME
TE
R
2
3
3
4
6
2
1
E. T
AR
PO
N A
VE
NU
E
E. JASMINE AVENUE
EXISTING
CYCADIA
CEMETERY
EX
IS
TIN
G S
ID
EW
AL
K
E. JASMINE AVENUE
EX
IS
TIN
G S
OD
T
O R
EM
AIN
WETLAND
EXISTING FIBER OPTIC
PULL BOX TO REMAIN
EXISTING TRAFFIC
CONTROL UTILITY
CABINETS AND
CONCRETE PADS
TO REMAIN
PROPOSED ORNMANETAL
FENCE AND COLUMNS (TYP.).
SEE CIVIL PLANS FOR MORE
INFORMATION
EX
IS
TIN
G S
ID
EW
AL
K
PR
OP
OS
ED
S
ID
EW
AL
K
PROPOSED ENTRY
MONUMENT. SEE CIVIL
PLANS FOR MORE
INFORMATION
EXISTING UTILITY
PEDESTAL TO REMAIN
SOD LIMIT
LINE (TYP)
8
1
0
4
6
8
8
8
12
1
4
1
6
1
8
MINOR CLEARING AND
PRUNING LIMITS.
SEE NOTE ABOVE
ONE FOOT OF
MULCH TO BE
INSTALLED IN
FRONT AND
BEHIND FENCE
(TYP. OF ALL)
EXISTING POWER LINE
POLE
1
0
1
5
6
7
8
9
9
9
1
1
11
11
1
2
1
2
1
3
1
4
1
6
1
7
1
8
5
5
1
0
1
5
6
6
7
7
8
8
9
9
1
1
1
2
1
3
1
4
STORMWATER POND
SEE CIVIL PLANS FOR MORE INFORMATION
20' BUILDING
SETBACK
15' WETLAND
BUFFER
20' BUILDING
SETBACK
PROPOSED CHAIN LINK
FENCE (TYP.). SEE CIVIL
PLANS FOR MORE
INFORMATION
MINOR CLEARING AND PRUNING NOTE:
CONTRACTOR WILL BE REQUIRED TO
PERFORM MINOR CLEARING AND PRUNING
FOR THE TREE SAVE AREA BETWEEN THE
SOD EDGE AND WETLAND AREA. THIS WILL
INCLUDE REMOVAL OF GENERAL DEBRIS,
INCLUDING TREES 2" CAL. OR LESS,
HANGING LIMBS, DEAD LIMBS ON TREES
AND ON THE GROUND. PINE NEEDLES WILL
BE REQUIRED WITHIN THE
AFOREMENTIONED AREA.
CYCADIA CEMETERY EAST
(PHASE I)
SEPTEMBER 2019
CITY OF
TARPON SPRINGS
00287-011.01
ANDREW HILL, PLA
LA6667073
PROJECT NO:
DATE:
SHEET NO:
LIC. NO.:
DATE
BY DATEDESCRIPTIONNO.
DESIGNED
DRAWN
Q.C.
APPROVED
CJC, JLG
CJC, JLG
CJC
LA 6667073
STATE
OF
A
N
D
R
E
W
D
.
H
I
L
L
CLEARWATER
380 PARK PLACE BLVD, STE 300, CLEARWATER, FL 33759
TEL: (727) 531 - 3505 FAX: (727) 431 - 1777
www.cardno.com Certificate of Authorization No. 29915
09-20-19
00 20' 40'
MATCHLINE-SEE SHEET L 1.01
PLANTING PLAN
L1.00
NOTE: ALL SOD TO BE
PLACED WITHIN POND SHALL
BE HARVESTED FROM
NON-MUCK GROWN FARMS.
MATCHLINE-SEE SHEET L 1.01
32
1
32
1
32
1
32
1
32
1
32
1
2
1
32
1
32
1
32
1
32
1
32
1
32
1
32
6
54
32
6
54
32
1
6
54
32
1
6
54
6
54
6
5
32
1
6
54
32
1
6
54
32
1
6
54
654
32
1
654
32
1
654
32
1
6
54
2
1
6
32
6
54
32
6
54
32
1
654
32
1
654
32
1
654
32
1
654
32
1
654
32
1
654
1
6
32
1
6
54
32
1
6
54
32
1
6
54
32
1
654
32
1
654
32
1
654
32
1
654
32
1
32
1
32
1
32
1
1
32
1
54
2
1
1
32
1
6
54
6
54
32
1
6
54
32
1
6
54
6
54
6
54
32
1
6
54
32
1
6
54
32
1
6
54
6
6
32
1
6
54
32
1
6
54
6
5
3
32
1
32
32
1
2
1
2
1
3
32
1
4
32
1
4
4
2
1
32
1
54
32
1
4
1
1
3
32
1
6
54
3
3
5
5
5
1
12
:1
MA
X
12:1
MAX
12:1
MAX
E. T
AR
PO
N A
VE
NU
E
61
156
EX
IS
TIN
G S
ID
EW
ALK
EX
IS
TIN
G A
SP
HA
LT
PA
D T
O R
EM
AIN
EX
IS
TIN
G S
OD
T
O R
EM
AIN
MAUSOLEUM
FUTURE
PHASE II
COMMITTAL
SHELTER
EXISTING
HYDRANT TO
REMAIN
EXISTING WELL TO REMAIN
PROPOSED SIDEWALK
PROPOSED SIDEWALK
1
0
2
0
1
2
1
4
1
6
1
8
2
2
2
4
2
6
2
0
2
2
2
4
2
6
ONE FOOT OF
MULCH TO BE
INSTALLED IN
FRONT AND
BEHIND FENCE
(TYP. OF ALL)
1
0
1
0
15
1
5
2
0
2
0
11
1
1
1
2
1
2
1
3
1
3
1
4
1
4
16
1
6
1
7
17
1
8
1
8
1
9
1
9
2
1
2
1
21
2
1
21
22
2
2
2
3
2
4
8' LANDSCAPE BUFFER
20' BUILDING
SETBACK
PROPOSED 5' RETAINING WALL
SEE CIVIL SET FOR FURTHER
INFORMATION
PROPOSED ORNMANETAL
FENCE AND COLUMNS (TYP.).
SEE CIVIL PLANS FOR MORE
INFORMATION
PROPOSED CHAIN LINK
FENCE (TYP.). SEE CIVIL
PLANS FOR MORE
INFORMATION
ENTIRE AREA AROUND WELL
TO BE MULCHED
37
79
1. CONTRACTOR IS REQUIRED TO PERFORM MINOR CLEARING AND GRUBBING SERVICES FOR ENTIRE SITE PRIOR TO INSTALLING PLANT MATERIAL.
THIS INCLUDES BUT IS NOT LIMITED TO REMOVAL OF WEEDS, TRASH, AND SCRUB LIKE MATERIAL. IT IS POSSIBLE THIS MAY INCLUDE SOME FINE
GRADING SERVICES TO ASSURE NO HOLES OR TRIPPING HAZARDS ARE PRESENT. CONTRACTOR SHOULD INCLUDE THIS IN BID PRICE.
2. CONTRACTOR SHALL NOTIFY CARDNO IMMEDIATELY IF EXISTING TREES SHOWN ON THIS PLAN AS REMAINING DO NOT EXIST. ADDITIONAL PLANT
MATERIAL MAY BE REQUIRED TO ACCOUNT FOR MISSING TREES.
3. ALL EXISTING PALMS SLATED TO REMAIN SHALL BE CLEANED UP AND DEBOOTED UP TO A REASONABLE HEIGHT APPROPRIATE TO OVERALL
HEIGHT. ALL VINES ON EXISTING TREES SHALL BE REMOVED.
4. AREAS OF THE LAWN MAY CONTAIN CATCH BASINS AND AREA DRAINS. CONTRACTOR SHALL USE BEST JUDGEMENT TO FINE GRADE AROUND
CATCH BASINS AND OTHER APPURTENANCES TO MINIMIZE EROSION AND MAINTAIN AESTHETIC VALUE. TREES LOCATED IN DRAINAGE WAYS
SHALL BE FIELD ADJUSTED TO PLACE TREES OUTSIDE OF DRAINAGE WAY. CONTACT LANDSCAPE ARCHITECT WITH ANY DISCREPANCIES.
5. CONTRACTOR TO FLAG ALL PROPERTY LINES, EASEMENT LINES, ETC. TO INSTALL PLANTING AND IRRIGATION AS PER PLANS. CONTRACTOR TO
CONTACT OWNER AND LANDSCAPE ARCHITECT PRIOR TO INSTALLATION IF ANY LOCATIONS ARE UNCLEAR
GENERAL LANDSCAPE NOTES
MISCELLANEOUSITEM SIZE COMMENTS
GROUNDCOVERS/SODITEM SIZE QUANTITY SPACING
LANDSCAPE PLANT MATERIAL SCHEDULETREESITEM SIZE QUANTITY SPACING
SHRUBS & ACCENTSITEM SIZE QUANTITY SPACING
SYMBOL
EXISTING TREES TO REMAIN, EVERGREEN & DECIDUOUS
CONTRACTOR TO PROTECT WITHIN DRIP LINES
SEE TREE PROTECTION
& DEMOLITION PLANS
TAXODIUM DISTICHUM
BALD CYPRESS
1.5" CAL.
6' HT.
7 AS SHOWN
QUERCUS VIRGINIANA
LIVE OAK
1.5" CAL.
6' HT.
10 AS SHOWN
ULMUS AMERICANA V. FLORIDANA
FLORIDA ELM
1.5" CAL.
6' HT.
9 AS SHOWN
PODOCARPUS MACROPHYLLA
PODOCARPUS
5 GAL.
54" HT.
190 5'-0" O.C.
MATURE: 6-7' HT. / 5' WD.
LIRIOPE MUSCARI
BIG BLUE LILY TURF
1 GAL. 196 1'-6" O.C.
STENOTAPHRUM SECUNDATUM 'SAPPHIRE'
ST. AUGUSTINE SAPPHIRE
SOD94,000 SF
LANDSCAPE ORDINANCE REQUIREMENTS:
MINIMUM PLANTING REQUIREMENT
SITE AREA:125,670 SF (DOES NOT INCLUDE
WETLAND AREA OR DETENTION POND)
MINIMUM REQUIRED TREES: 71 TREES (8 FOR FIRST 15,000SF
AND 1 FOR EVERY 2,000SF IN EXCESS
OF THAT)
EXISTING TREES RETAINED: 43 TREES
PROPOSED TREES: 44 TREES
TOTAL TREES: 87 TREES
VUA REQUIREMENTS
PROPOSED PARKING SPACES: 43 SPACES
REQUIRED INTERIOR LANDSCAPE AREA:800 SF
PROPOSED INTERIOR LANDSCAPE AREA:2,245 SF
REQUIRED TREES: 8 TREES
PROPOSED TREES: 8 TREES (6 PROPOSED AND 2 EXISTING)
DETENTION POND REQUIREMENTS
TOTAL POND AREA FROM T.O.B.: 7,030 SF
20% OF TOTAL AREA: 1,406 SF
REQUIRED TREES: 5 (1 PER 300 SF OF THE
CALCULATED 20% AREA)
PROPOSED TREES: 5
EAST BUFFER REQUIREMENTS
WIDTH: 8 FT
LENGTH:330 LF
REQUIRED TREES: 13 TREES (1 PER 25 LF)
PROPOSED TREES:13 TREES
REQUIRED SHRUBS: 1 HEDGE ROW
PROPOSED SHRUBS: 1 HEDGE ROW
NUMBER INDICATED ONHATCH THROUGHOUTDRAWING REFLECTS THENUMBER OF PLANTS IN THATPARTICULAR AREA
MULCH: ALL SHRUB BEDS SHALL CONTAIN A 3" LAYER OF SHREDDED CYPRESS MULCH.
CONTRACTOR TO PLACE MIN. 4' DIAMETER CYPRESS MULCH CIRCLE AROUND ALL TREES IN SOD (TYP.)
COMMENTS
ILEX VOMITORIA
YAUPON HOLLY
5 GAL.
54" HT.
14 5'-0" O.C.
MATURE: 6-7' HT. / 5' WD.
ACACIA FARNESIANA
SWEET ACACIA
1.5" CAL.
6' HT.
15 AS SHOWN
MAGNOLIA GRANDIFLORA
SOUTHERN MAGNOLIA
1.5" CAL.
6' HT.
3 AS SHOWN
ILEX VOMITORIA 'SCHILLINGS'
SHILLINGS HOLLY
3 GAL.
18" GAL.
41 3'-0" O.C.
12
CYCADIA CEMETERY EAST
(PHASE I)
SEPTEMBER 2019
CITY OF
TARPON SPRINGS
00287-011.01
ANDREW HILL, PLA
LA6667073
PROJECT NO:
DATE:
SHEET NO:
LIC. NO.:
DATE
BY DATEDESCRIPTIONNO.
DESIGNED
DRAWN
Q.C.
APPROVED
CJC, JLG
CJC, JLG
CJC
LA 6667073
STATE
OF
A
N
D
R
E
W
D
.
H
I
L
L
CLEARWATER
380 PARK PLACE BLVD, STE 300, CLEARWATER, FL 33759
TEL: (727) 531 - 3505 FAX: (727) 431 - 1777
www.cardno.com Certificate of Authorization No. 29915
09-20-19
MATCHLINE-SEE SHEET L 1.00
00 20' 40'
PLANTING PLAN
L1.01
MATCHLINE-SEE SHEET L 1.00
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
5
4
2
1
6
5
4
2
1
6
5
4
2
6
5
4
2
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
3
3
6
5
4
3
2
6
5
4
6
5
4
3
2
1
6
5
4
3
2
1
4
3
2
1
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
5
4
3
2
1
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
6
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
2
1
3
2
1
3
2
1
3
2
1
3
2
1
6
5
4
5
4
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
6
5
4
3
2
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
6
5
4
6
5
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
6
5
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
2
1
6
3
2
6
5
4
3
2
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
1
6
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
1
3
2
1
5
4
3
2
1
3
2
1
3
2
1
2
1
3
3
2
1
3
5
4
1
3
3
3
3
3
3
1
3
2
1
6
5
4
3
2
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
6
5
4
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
6
6
3
2
1
6
5
4
3
2
1
6
5
4
6
5
3
3
2
1
3
2
3
2
1
2
1
1
1
3
2
1
3
2
1
2
1
2
1
3
3
2
1
4
3
2
1
4
4
2
1
3
2
1
5
4
3
2
1
4
1
1
2
3
3
3
4
3
2
1
6
2
6
5
4
3
3
5
1
5
5
1
12:1
MAX
12:1
MA
X
12:1
MA
X
IRRIGATION MATERIALS AND LEGEND
UNDERPAVEMENT SLEEVING.
PVC SCH 40 - ALL ROADWAY CROSSINGS SHALL HAVE (1)
4" SLEEVE WITH (2) 2" SLEEVES. ALL OTHER SLEEVES TO
BE 4" UNLESS OTHERWISE NOTED.
NOTE: CONTRACTOR TO PROVIDE ANY NECESSARY
SLEEVING UNDER PAVEMENT NOT SHOWN IN PLANS
2" IRRIGATION MAINLINE - SOLVENT WELD PVC (PURPLE PIPE)
ASTM D2241 - CLASS 200 - SDR 21
QUICK COUPLING VALVE AND VALVE KEY
MFG.: RAINBIRD (MODEL: 5 NP)
RESILIENT WEDGE ISOLATION VALVE - SIZE PER LINE
STAINLESS STEEL BALL VALVE - SIZE PER LINE
MFG.: LEEMCO FITTINGS (MODEL: LBT-XX-SS)
GENERAL NOTES:
1. IRRIGATION SYSTEM DESIGN IS BASED ON 32 GPM AND 105 PSI. SUPPLY PRESSURE IS 40 PSI. A
BOOSTER PUMP IS REQUIRED TO OPERATE AS DESIGNED.
2. IRRIGATION DESIGN IS FROM THE POINT OF CONNECTION (POC) ONLY. THE DESIGN IS BASED ON
GALLONS PER MINUTE (GPM) AND POUNDS PER SQUARE INCH (PSI) AS FURNISHED BY OTHERS.
3. IRRIGATION CONTRACTOR TO VERIFY POINT OF CONNECTION IN THE FIELD AND CONFIRM MINIMUM
DISCHARGE REQUIRED AT POINT OF CONNECTION AS REQUIRED BY PROPOSED IRRIGATION
EQUIPMENT PRIOR TO INSTALLATION. CONTACT OWNER'S REPRESENTATIVE WITH ANY
DISCREPANCIES IMMEDIATELY BEFORE INSTALLATION.
4. THE PRESSURE REQUIREMENT AT THE POINT OF CONNECTION IS BASED ON NO MORE THAN 5 FEET
OF ELEVATION CHANGE IN THE AREAS OF IRRIGATION.
5. DETAILED AS-BUILTS WILL BE REQUIRED UPON COMPLETION OF PROJECT. AS-BUILTS TO INCLUDE
ALL DECODER ADDRESSES AS WELL AS GPS LOCATIONS OF EACH VALVE BOX. SEE DETAIL SHEET
FOR FURTHER INFORMATION
6. CONTRACTOR TO USE CONTINUOUS RUNS FOR ALL PROPOSED CONTROL WIRES. IF NECESSARY,
LOCATE ALL WIRE SPLICES IN VALVE BOX. BUNDLE WIRES IN VALVE BOX WITH MINIMUM 24" OF
EXCESS CABLE PER BUNDLE. ALL SPLICES MUST BE WATERPROOF WITH 3M DBY/DBR-6
CONNECTORS.
7. ALL MATERIAL USED SHALL BE INSTALLED AS PER PLAN AND AS PER MANUFACTURER'S
SPECIFICATIONS. ALL DEVIATIONS FROM DRAWINGS OR MATERIALS SHALL BE APPROVED BY THE
OWNER OR LANDSCAPE ARCHITECT.
8. CONTRACTOR TO PROVIDE ANY STAKING NECESSARY FOR PROPERTY LINES, EASEMENT LINES, ETC.
TO INSTALL PLANTING AND IRRIGATION AS PER PLANS
9. LOCATE VALVES AND VALVE BOXES IN SHRUB BED WHENEVER POSSIBLE. IF NECESSARY TO LOCATE
IN LAWN, LOCATE A MINIMUM OF 36" AWAY FROM PLANTER BED EDGE.
10. CONTRACTOR IS RESPONSIBLE TO ENSURE THAT ALL IRRIGATION EQUIPMENT IS MARKED
APPROPRIATELY TO DESIGNATE NON-POTABLE WATER AND WITH PURPLE INDICATORS. ALL VALVE
BOXES SHALL HAVE PURPLE LIDS WITH TEXT THAT READS "DO NOT DRINK". ALL PIPES TO BE
PURPLE PIPE. ALL IRRIGATION HEADS WILL HAVE PURPLE CAPS
11. PIPE LAYOUT AND VALVE LOCATION IS DIAGRAMMATIC. VALVES AND PIPE SHOWN IN BUILDING OR
PAVED AREAS ARE FOR GRAPHIC CLARITY ONLY. ALL VALVES AND MAINLINE SHALL BE INSTALLED
WITHIN LANDSCAPE AREAS WITHIN PROPERTY. LOCATION OF IRRIGATION COMPONENTS SHOWN
ON DRAWING IS APPROXIMATE. ACTUAL PLACEMENT MAY VARY SLIGHTLY AS REQUIRED TO
ACHIEVE FULL, EVEN COVERAGE.
12. LAWN INTERIOR WILL BE DEVIDED INTO BLOCK, LOT AND GRAVE. NO IRRIGATION PIPE OR
EQUIPMENT OF ANY KIND WILL BE ALLOWED WITHIN BLOCKS. IRRIGATION CONTRACTOR TO
REFERENCE GEOMETRIC CONTROL PLAN FOR LOT & GRAVE DETAIL. CONTACT OWNER'S
REPRESENTATIVE WITH ANY DISCREPANCIES.
13. SEE DETAIL SHEET L 3.01 FOR FURTHER IRRIGATION NOTES & DETAILS
AUTOMATIC CONTROLLER WITH CENTRAL CONTROL
RAINBIRD (MODEL: ESP-LXD50)
IQ CENTRAL CONTROL: IQ-NCC
STAINLESS STEEL PEDESTAL AND CABINET: LXMMSSPED & ESP-LXMMSS
WIRELESS RAIN SENSOR - RAINBIRD (MODEL: WR2-RFC)
TO BE INSTALLED ON ROOF OF BUILDING IF APPROVED BY
OWNER. RAIN SENSOR SHALL BE INSTALLED PER
MANUFACTURER RECOMMENDATION
SURGE PROTECTOR/GROUNDING PLATE.
MFG.: RAINBIRD SENSOR DECODER (MODEL: LSP-1)
INSTALL EVERY 500' OF CONTROL WIRE OR 10 DECODERS, WHICHEVER IS
LESSER
EARTH GROUND RESISTANCE READINGS TO BE 10 OHMS OR LESS.
RESISTANCE READINGS WILL BE REQUIRED TO BE TESTED BY CONTRACTOR
AND A REPORT VERIFYING READINGS HAVE MET SPECIFICATIONS SUBMITTED
TO OWNER PRIOR TO FINAL PAYMENT BEING RELEASED.
DC
DECODER CABLE FUSE DEVICES (DCFD) (MFG: PAIGE MODEL: DCFD)
CONTRACTOR TO INSTALL (DCFD) AT ALL DIRECTIONAL SPLICES IN A VALVE BOX.
CONTRACTOR TO PROVIDE ANY NECESSARY (DCFD) NOT SHOWN IN PLANS
PIPE, SLEEVING AND COMMUNICATION WIRE
TWO-WIRE CONTROL WIRE. 14 AWG
CONTRACTOR TO EXTEND CONTROL WIRE TO ALL VALVES AND STUB OUTS
AS SHOWN.
CONTRACTOR TO USE CONTINUOUS RUNS FOR ALL PROPOSED CONTROL
WIRES. IF NECESSARY, LOCATE ALL WIRE SPLICES IN VALVE BOX. BUNDLE
WIRES IN VALVE BOX WITH MINIMUM 24" OF EXCESS CABLE PER BUNDLE.
ALL SPLICES MUST BE WATERPROOF WITH 3M DBY/DBR-6 CONNECTORS.
MV FS
MASTER VALVE & FLOW SENSOR - SEE SHEET L2.01
MASTER VALVE: RAINBIRD (MODEL: 200-EFB-CP-PRS-D)
FLOW SENSOR: RAINBIRD (MODEL: FS150B)
INSTALL PER MANUFACTURER RECOMMENDATIONS
BP
POINT OF CONNECTION IS A 1" RECLAIMED METER. PRESSURE
READING PROVIDED BY CITY IS 40 PSI AFTER METER.
BOOSTER PUMP - DESIGN/BUILD BY IRRIGATION CONTRACTOR
00 30' 60'
EXISTING
CYCADIA
CEMETERY
TARPON
SPRINGS
YOUTH
SOCCER
E. TARPON AVENUE
N. JASM
IN
E AVEN
UE
MAUSOLEUM
FUTURE
PHASE II
CO
MM
ITTAL
SH
ELTER
STO
RM
WATER
PO
ND
DESIGN/BUILD NOTE: PORTIONS OF THE IRRIGATION SYSTEM HAVE BEEN DESIGNED AND SPECIFIED BY
CARDNO. THE INTERIOR OF THE SITE WILL BE DESIGN/BUILD BY IRRIGATION CONTRACTOR. THESE
AREAS WILL INCLUDE ALL PROPOSED PLANTINGS AND TURF AREAS NOT CURRENTLY IRRIGATED WITHIN
THIS IRRIGATION PLAN. ALL OTHER AREAS TO BE BID AND INSTALLED AS PER PLAN. BELOW ARE KNOWN
REQUIREMENTS TO ADHERE TO FOR THE PREPARATION OF DESIGN DOCUMENTS:
· THE INTERIOR LAWN WILL BE DIVIDED INTO BLOCK, LOT AND GRAVE. NO IRRIGATION LINES OR
EQUIPMENT ARE ALLOWED WITHIN THE BLOCKS. REFER TO GEOMETRIC CONTROL PLAN FOR BLOCK,
LOT AND GRAVE DETAILS.
· HEADSTONES WILL BE UTILIZED IN LOTS. IRRIGATION LAYOUT AND COVERAGE SHOULD
ACCOMMODATE HEADSTONES
· IT IS ANTICIPATED THAT 60 PSI ROTORS WILL BE NEEDED TO IRRIGATE THE TURF AREAS
IN-BETWEEN GRAVES FROM THE PERIMETER OF THE GRAVE BLOCKS. THERE ARE A TOTAL OF THREE
BLOCKS
· IT IS ANTICIPATED THAT THE FINAL DESIGN WILL REQUIRE A BOOSTER PUMP CAPABLE OF
PRODUCING OVER 100 PSI. CONTRACTOR WILL BE REQUIRED TO SPECIFY AND INSTALL BOOSTER
PUMP CAPABLE OF MEETING DESIGN REQUIREMENTS
WETLAND
OVERALL MAINLINE
ROUTING PLAN
L2.00
DC
DC
CYCADIA CEMETERY EAST
(PHASE I)
SEPTEMBER 2019
CITY OF
TARPON SPRINGS
00287-011.01
ANDREW HILL, PLA
LA6667073
PROJECT NO:
DATE:
SHEET NO:
LIC. NO.:
DATE
BY DATEDESCRIPTIONNO.
DESIGNED
DRAWN
Q.C.
APPROVED
CJC, JLG
CJC, JLG
CJC
LA 6667073
STATE
OF
A
N
D
R
E
W
D
.
H
I
L
L
CLEARWATER
380 PARK PLACE BLVD, STE 300, CLEARWATER, FL 33759
TEL: (727) 531 - 3505 FAX: (727) 431 - 1777
www.cardno.com Certificate of Authorization No. 29915
09-20-19
DC
DC
32
1
32
1
32
1
32
1
32
1
6
54
32
1
6
54
32
1
54
2
1
654
2
1
654
2
654
2
654
32
1
654
32
1
654
32
1
3
3
6
54
32
6
54
6
54
32
1
6
54
32
1
4
32
1
4
32
1
6
54
32
1
6
54
32
1
54
32
1
32
1
6
54
32
1
6
54
32
1
6
54
32
1
654
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
3
2
1
6
54
32
1
6
54
32
1
6
54
6
32
1
32
1
32
1
32
1
6
54
54
32
1
32
1
32
1
32
1
32
1
6
54
32
1
6
54
32
1
654
32
1
654
32
1
654
32
1
654
32
1
654
32
1
654
32
1
654
32
1
654
32
1
654
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
6
5
32
1
6
54
32
1
6
54
32
1
32
1
32
1
32
1
3
2
1
3
3
2
1
3
54
3
3
3
3
3
3 1
32
1
654
32
654
32
1
654
32
1
654
32
1
654
32
1
654
32
1
6
54
32
1
6
54
32
1
6
54
32
1
6
54
32
1
654
32
1
6
54
32
1
6
5
2
1
1
1
32
1
32
1
2 3
3
4
6
2
1
NOTE: EASEMENT LINES HAVE BEEN REMOVED
FROM IRRIGATION PLAN FOR GRAPHICAL CLARITY.
REFER TO PLANTING AND SITE PLAN FOR
EASEMENT LINE AND LOCATION.
NOTE: PIPE LAYOUT AND VALVE LOCATION IS
DIAGRAMMATIC. VALVES AND PIPE SHOWN IN
BUILDING OR PAVED AREAS ARE FOR GRAPHIC
CLARITY ONLY. ALL VALVES AND MAINLINE SHALL BE
INSTALLED WITHIN LANDSCAPE AREAS WITHIN
PROPERTY. LOCATION OF IRRIGATION COMPONENTS
SHOWN ON DRAWING IS APPROXIMATE. ACTUAL
PLACEMENT MAY VARY SLIGHTLY AS REQUIRED TO
ACHIEVE FULL, EVEN COVERAGE. NO EQUIPMENT IS
ALLOWED WITHIN GRAVE LOTS
NOTE: NO MAINLINE SHALL BE INSTALLED IN RIGHT
OF WAY. CONTRACTOR TO LIMIT THE AMOUNT OF
LATERALS WITHIN RIGHT OF WAY AT ALL TIMES.
POINT OF CONNECTION
IS LOCATED IN THIS APPROXIMATE AREA. POINT OF
CONNECTION IS A 1" INCH METER PROVIDED AND
INSTALLED BY OWNER. COORDINATE WITH OWNER ON
EXACT LOCATION AND SCHEDULE OF INSTALLATION.
BOOSTER PUMP TO BE INSTALLED WITHIN PLANTING BED
BEHIND FENCE AND CONCEALED BY PLANTINGS AS BEST AS
POSSIBLE FROM E. JASMINE AVENUE
AUTOMATIC IRRIGATION CONTROLLER
IRRIGATION CONTRACTOR TO COORDINATE POWER SUPPLY
PRIOR TO CONSTRUCTION. CONSULT OWNER'S
REPRESENTATIVE ON FINAL LOCATION PRIOR TO POURING
CONTROLLER FOOTING. CONTROLLER SHALL BE LOCATED
WITHIN PROPOSED PLANTING BED BEHIND FENCE AND
CONCEALED BY PLANTINGS AS BEST AS POSSIBLE FROM E.
JASMINE AVENUE. CONTRACTOR TO INSTALL WIRELESS RAIN
SENSOR ON COLUMN' NEAR CONTROLLER. CONTRACTOR TO
ENSURE RAIN SENSOR IS OUT OF CURRENT AND FUTURE
DRIPLINE OF TREES IN IMMEDIATE AREA.
MVFS
EXISTIN
G SID
EW
ALK
EXISTIN
G SID
EW
ALK
SID
EW
ALK
E. T
AR
PO
N A
VE
NU
E
E. JASMINE AVENUE
E. JASMINE AVENUE
STORMWATER POND
SEE CIVIL PLANS FOR MORE INFORMATION
SIDEWALK
RIG
HT O
F W
AY
RIGHT OF WAY
RIG
HT O
F W
AY
1
30
3
28
2
--
4
30
5
30
6
19.5
7
11
8
--
32
30
19
--
BP
RIGHT OF WAY
SID
EW
ALK
15'
IRRIGATION MATERIALS AND LEGEND
PIPE, SLEEVING AND COMMUNICATION WIRE
SYM P.S.I. RADIUS
3.70, 2.78, 1.85, .92 30
12'302.60, 1.95, 1.3, .65
DESCRIPTION
1.58, .79, .39
GPM
30 10'
8'1.05, .52, .26 30
1.21 4' X 24'
30 4' X 12'
SPRAY HEADS
.61
30
UNDERPAVEMENT SLEEVING.
PVC SCH 40 - ALL ROADWAY CROSSINGS SHALL HAVE (1)
4" SLEEVE WITH (2) 2" SLEEVES. ALL OTHER SLEEVES TO
BE 4" UNLESS OTHERWISE NOTED.
NOTE: CONTRACTOR TO PROVIDE ANY NECESSARY
SLEEVING UNDER PAVEMENT NOT SHOWN IN PLANS
RAINBIRD RD-06-S-P30-NP-15SST POP-UP SPRINKLER
RAINBIRD RD-06-S-P30-NP-15EST POP-UP SPRINKLER
RAINBIRD RD-06-S-P30-NP-8 SPRAY POP-UP SPRINKLER, F, H, Q,
RAINBIRD RD-06-S-P30-NP-10 POP-UP SPRINKLER, F, H, Q
RAINBIRD RD-06-S-P30-NP-12 POP-UP SPRINKLER, F, TQ, H, Q
RAINBIRD RD-06-S-P30-NP-15 POP-UP SPRINKLER, F, TQ, H, Q
GPM 20-50 MFG.: 1 1/2" RAINBIRD VALVE (MODEL: 150-PESBR-PRS-D)
1
34
CONTROLLER VALVES AND APPURTENANCES
1" XERIGATION COMMERCIAL CONTROL ZONE KIT -
MFG.: RAINBIRD - MODEL: XCZ-100-PRBR
USE PSI-M30X REGULATOR FOR FLOWS EXCEEDING 5 GPM
GPM 0-20 MFG.: 1" RAINBIRD VALVE (MODEL: 100-PESBR-PRS-D)
DRIP IRRIGATION STATION NUMBER
LATERAL PIPE-CLASS 200-PURPLE PIPE
STATION NUMBER
GALLONS PER MINUTE
(CONTRACTOR TO LABEL VALVES IN CONTROLLER AND
AS BUILTS ACCORDING TO DECODER ADDRESS)
TWO WIRE FIELD DECODER FOR REMOTE CONTROL VALVE
MFG.: RAINBIRD FD-SERIES DECODER (MODEL: FD-101)
11
--
GALLONS PER MINUTE
DRIP IRRIGATION NOTES:
1. ALL 1/2" POLY TUBING TO BE SECURED BY RAINBIRD
EASY FIT COMPRESSION FITTINGS
2. 1/4" TUBING NOT TO EXCEED 5 LF, RAINBIRD MODEL
PT-025. 1/4" BARB TRANSFER FITTINGS TO BE
RAINBIRD
3. INSTALL ONE RAINBIRD XERI-SPRAY (MODEL XS-90) ON
12" POLY FLEX RISER ON EACH DRIP ZONE FOR USUAL
INSPECTION OF SYSTEM. INSTALL 3' FROM VALVE BOX,
ABOVE GRADE MINIMUM 5' FROM PAVEMENT EDGE.
4. EMITTER SCHEDULE - 2.5" CALIPER TREES (PLANTING
BEDS ONLY) - 14 GPH; SHRUB - 5 GPH; GROUNDCOVER -
1 GPH.
DRIP IRRIGATION
IRRIGATION LATERALS TO BE SIZED
ACCORDING TO FLOW CHART AND
FLOWS ACCUMULATED. PIPE SIZES
SHALL BE ADJUSTED IN THE FIELD TO
MATCH AS-BUILT CONDITIONS.
CONTROLLER VALVES AND APPURTENANCES
LATERAL FLOW CHART
3/4" = 0-10 GPM
1" = 11-16 GPM
1 1/4" = 17-26 GPM
1 1/2" = 27-35 GPM
2" = 35-55 GPM
END FLUSH CAP (MODEL:MDCFCAP)
INSTALL IN VALVE BOX. TYPICAL AT ALL ENDS OF
XERI-TUBE RUNS
MV FS
PRESSURE REGULATING ELECTRIC REMOTE CONTROL VALVE AND
TWO WIRE DECODER
SHRUB ZONES: 1/2" DIA RAINBIRD BLACK STRIPE TUBING
NOT TO EXCEED 250 LF OR 4.0 GPM FOR ANY SINGLE RUN
MFG: RAINBIRD - MODEL: XBS 500P
CV
HEAD DRAINAGE
LOCATE AS NECESSARY TO AVOID LOW
1.73
KING BROS. IN LINE SWING CHECK VALVE
30
(MODEL # KSC-(LINE SIZE)-S
9' X 18'RAINBIRD RD-06-S-P30-NP-9SST POP-UP SPRINKLER
RAINBIRD RD-06-S-P30-NP-RVAN18 POP-UP SPRINKLER, F, H, Q 16'1.96, 1.01, .5
QUICK COUPLING VALVE AND VALVE KEY
MFG.: RAINBIRD (MODEL: 5 NP)
30
AUTOMATIC CONTROLLER WITH CENTRAL CONTROL
RAINBIRD (MODEL: ESP-LXD50)
IQ CENTRAL CONTROL: IQ-NCC
STAINLESS STEEL PEDESTAL AND CABINET: LXMMSSPED & ESP-LXMMSS
WIRELESS RAIN SENSOR - RAINBIRD (MODEL: WR2-RFC)
TO BE INSTALLED ON ROOF OF BUILDING IF APPROVED BY
OWNER. RAIN SENSOR SHALL BE INSTALLED PER
MANUFACTURER RECOMMENDATION
RESILIENT WEDGE ISOLATION VALVE - SIZE PER LINE
STAINLESS STEEL BALL VALVE - SIZE PER LINE
MFG.: LEEMCO FITTINGS (MODEL: LBT-XX-SS)
NOTE: REFER TO SHEET L2.00 FOR
ADDITIONAL DETAILS AND GENERAL NOTES
POINT OF CONNECTION IS A 1" RECLAIMED METER. PRESSURE
READING PROVIDED BY CITY IS 40 PSI AFTER METER.
BOOSTER PUMP - DESIGN/BUILD BY IRRIGATION CONTRACTORBP
MASTER VALVE & FLOW SENSOR
MASTER VALVE: RAINBIRD (MODEL: 200-EFB-CP-PRS-D)
FLOW SENSOR: RAINBIRD (MODEL: FS150B) WITH
SENSOR DECODER (SD210TURF)
INSTALL PER MANUFACTURER RECOMMENDATIONS
2" IRRIGATION MAINLINE - SOLVENT WELD PVC (PURPLE PIPE)
ASTM D2241 - CLASS 200 - SDR 21
SURGE PROTECTOR/GROUNDING PLATE.
MFG.: RAINBIRD SENSOR DECODER (MODEL: LSP-1)
INSTALL EVERY 500' OF CONTROL WIRE OR 10 DECODERS, WHICHEVER IS
LESSER
EARTH GROUND RESISTANCE READINGS TO BE 10 OHMS OR LESS.
RESISTANCE READINGS WILL BE REQUIRED TO BE TESTED BY CONTRACTOR
AND A REPORT VERIFYING READINGS HAVE MET SPECIFICATIONS SUBMITTED
TO OWNER PRIOR TO FINAL PAYMENT BEING RELEASED.
IRRIGATION PLAN
L2.01
00 20' 40'
MATCHLINE-SEE SHEET L 2.02 MATCHLINE-SEE SHEET L 2.02
CYCADIA CEMETERY EAST
(PHASE I)
SEPTEMBER 2019
CITY OF
TARPON SPRINGS
00287-011.01
ANDREW HILL, PLA
LA6667073
PROJECT NO:
DATE:
SHEET NO:
LIC. NO.:
DATE
BY DATEDESCRIPTIONNO.
DESIGNED
DRAWN
Q.C.
APPROVED
CJC, JLG
CJC, JLG
CJC
LA 6667073
STATE
OF
A
N
D
R
E
W
D
.
H
I
L
L
CLEARWATER
380 PARK PLACE BLVD, STE 300, CLEARWATER, FL 33759
TEL: (727) 531 - 3505 FAX: (727) 431 - 1777
www.cardno.com Certificate of Authorization No. 29915
09-20-19
NOTE: CONTRACTOR TO COORDINATE AND
OBTAIN ENCROACHMENT PERMIT PRIOR TO
INSTALLING IRRIGATION WITHIN THE
RIGHT OF WAY ALONG BOTH ROADS. NO
CONSTRUCTION MAY COMMENCE PRIOR TO
OBTAINING THE ENCROACHMENT PERMIT
ALONG E. TARPON SPRINGS AVENUE AND E.
JASMINE AVENUE
32
1
3
2
1
32
1
32
1
32
1
32
1
2
1
32
1
32
1
32
1
32
1
32
1
32
1
32
6
54
32
6
54
32
1
6
54
32
1
6
54
6
54
6
5
32
1
6
54
32
1
6
54
32
1
654
654
32
1
654
32
1
654
32
1
654
2
1
6
32
6
54
32
6
54
32
1
6
54
32
1
654
32
1
654
32
1
654
32
1
654
32
1
654
1
6
32
1
6
54
32
1
6
54
32
1
6
54
32
1
654
32
1
654
32
1
654
32
1
654
32
1
32
1
32
1
32
1
1
32
1
54
2
1
1
32
1
6
54
6
54
32
1
6
54
32
1
6
54
6
54
6
54
32
1
6
54
32
1
6
54
32
1
6
54
6
6
32
1
654
32
1
654
65
3
32
1
32
32
1
2
1
2
1
3
32
1
4
32
1
4
4
2
1
32
1
54
3
2
1
4
1
1
3
32
1
6
54
3
3
5
5
5
1
12:1
MA
X
12:1
MAX
12:1
MAX
EXISTIN
G SID
EW
ALK
EXISTIN
G SID
EW
ALK
E. T
AR
PO
N A
VE
NU
E
MAUSOLEUM
FUTURE
PHASE IICOMMITTAL
SHELTER
RIG
HT O
F W
AY
RIG
HT O
F W
AY
9
19.5
10
30
11
23
12
27
14
30
16
5
13
30
15
--
18
30
17
--
NOTE: NO MAINLINE SHALL BE INSTALLED IN RIGHT
OF WAY. CONTRACTOR TO LIMIT THE AMOUNT OF
LATERALS WITHIN RIGHT OF WAY AT ALL TIMES.
NOTE: PIPE LAYOUT AND VALVE LOCATION IS
DIAGRAMMATIC. VALVES AND PIPE SHOWN IN
BUILDING OR PAVED AREAS ARE FOR GRAPHIC
CLARITY ONLY. ALL VALVES AND MAINLINE SHALL BE
INSTALLED WITHIN LANDSCAPE AREAS BETWEEN
RIGHT-OF-WAY AND PROPERTY LINE. LOCATION OF
IRRIGATION COMPONENTS SHOWN ON DRAWING IS
APPROXIMATE. ACTUAL PLACEMENT MAY VARY
SLIGHTLY AS REQUIRED TO ACHIEVE FULL, EVEN
COVERAGE.
NOTE: EASEMENT LINES HAVE BEEN REMOVED
FROM IRRIGATION PLAN FOR GRAPHICAL CLARITY.
REFER TO PLANTING AND SITE PLAN FOR
EASEMENT LINE AND LOCATION.
SID
EW
ALK
SIDEWALK
SIDEWALK
15'
IRRIGATION MATERIALS AND LEGEND
PIPE, SLEEVING AND COMMUNICATION WIRE
SYM P.S.I. RADIUS
3.70, 2.78, 1.85, .92 30
12'302.60, 1.95, 1.3, .65
DESCRIPTION
1.58, .79, .39
GPM
30 10'
8'1.05, .52, .26 30
1.21 4' X 24'
30 4' X 12'
SPRAY HEADS
.61
30
UNDERPAVEMENT SLEEVING.
PVC SCH 40 - ALL ROADWAY CROSSINGS SHALL HAVE (1)
4" SLEEVE WITH (2) 2" SLEEVES. ALL OTHER SLEEVES TO
BE 4" UNLESS OTHERWISE NOTED.
NOTE: CONTRACTOR TO PROVIDE ANY NECESSARY
SLEEVING UNDER PAVEMENT NOT SHOWN IN PLANS
RAINBIRD RD-06-S-P30-NP-15SST POP-UP SPRINKLER
RAINBIRD RD-06-S-P30-NP-15EST POP-UP SPRINKLER
RAINBIRD RD-06-S-P30-NP-8 SPRAY POP-UP SPRINKLER, F, H, Q,
RAINBIRD RD-06-S-P30-NP-10 POP-UP SPRINKLER, F, H, Q
RAINBIRD RD-06-S-P30-NP-12 POP-UP SPRINKLER, F, TQ, H, Q
RAINBIRD RD-06-S-P30-NP-15 POP-UP SPRINKLER, F, TQ, H, Q
GPM 20-50 MFG.: 1 1/2" RAINBIRD VALVE (MODEL: 150-PESBR-PRS-D)
1
34
CONTROLLER VALVES AND APPURTENANCES
1" XERIGATION COMMERCIAL CONTROL ZONE KIT -
MFG.: RAINBIRD - MODEL: XCZ-100-PRBR
USE PSI-M30X REGULATOR FOR FLOWS EXCEEDING 5 GPM
GPM 0-20 MFG.: 1" RAINBIRD VALVE (MODEL: 100-PESBR-PRS-D)
DRIP IRRIGATION STATION NUMBER
LATERAL PIPE-CLASS 200-PURPLE PIPE
STATION NUMBER
GALLONS PER MINUTE
(CONTRACTOR TO LABEL VALVES IN CONTROLLER AND
AS BUILTS ACCORDING TO DECODER ADDRESS)
TWO WIRE FIELD DECODER FOR REMOTE CONTROL VALVE
MFG.: RAINBIRD FD-SERIES DECODER (MODEL: FD-101)
11
--
GALLONS PER MINUTE
DRIP IRRIGATION NOTES:
1. ALL 1/2" POLY TUBING TO BE SECURED BY RAINBIRD
EASY FIT COMPRESSION FITTINGS
2. 1/4" TUBING NOT TO EXCEED 5 LF, RAINBIRD MODEL
PT-025. 1/4" BARB TRANSFER FITTINGS TO BE
RAINBIRD
3. INSTALL ONE RAINBIRD XERI-SPRAY (MODEL XS-90) ON
12" POLY FLEX RISER ON EACH DRIP ZONE FOR USUAL
INSPECTION OF SYSTEM. INSTALL 3' FROM VALVE BOX,
ABOVE GRADE MINIMUM 5' FROM PAVEMENT EDGE.
4. EMITTER SCHEDULE - 2.5" CALIPER TREES (PLANTING
BEDS ONLY) - 14 GPH; SHRUB - 5 GPH; GROUNDCOVER -
1 GPH.
DRIP IRRIGATION
IRRIGATION LATERALS TO BE SIZED
ACCORDING TO FLOW CHART AND
FLOWS ACCUMULATED. PIPE SIZES
SHALL BE ADJUSTED IN THE FIELD TO
MATCH AS-BUILT CONDITIONS.
CONTROLLER VALVES AND APPURTENANCES
LATERAL FLOW CHART
3/4" = 0-10 GPM
1" = 11-16 GPM
1 1/4" = 17-26 GPM
1 1/2" = 27-35 GPM
2" = 35-55 GPM
END FLUSH CAP (MODEL:MDCFCAP)
INSTALL IN VALVE BOX. TYPICAL AT ALL ENDS OF
XERI-TUBE RUNS
MV FS
PRESSURE REGULATING ELECTRIC REMOTE CONTROL VALVE AND
TWO WIRE DECODER
SHRUB ZONES: 1/2" DIA RAINBIRD BLACK STRIPE TUBING
NOT TO EXCEED 250 LF OR 4.0 GPM FOR ANY SINGLE RUN
MFG: RAINBIRD - MODEL: XBS 500P
CV
HEAD DRAINAGE
LOCATE AS NECESSARY TO AVOID LOW
1.73
KING BROS. IN LINE SWING CHECK VALVE
30 9' X 18'
(MODEL # KSC-(LINE SIZE)-S
RAINBIRD RD-06-S-P30-NP-9SST POP-UP SPRINKLER
RAINBIRD RD-06-S-P30-NP-RVAN18 POP-UP SPRINKLER, F, H, Q 16'1.96, 1.01, .5
QUICK COUPLING VALVE AND VALVE KEY
MFG.: RAINBIRD (MODEL: 5 NP)
30
AUTOMATIC CONTROLLER WITH CENTRAL CONTROL
RAINBIRD (MODEL: ESP-LXD50)
IQ CENTRAL CONTROL: IQ-NCC
STAINLESS STEEL PEDESTAL AND CABINET: LXMMSSPED & ESP-LXMMSS
WIRELESS RAIN SENSOR - RAINBIRD (MODEL: WR2-RFC)
TO BE INSTALLED ON ROOF OF BUILDING IF APPROVED BY
OWNER. RAIN SENSOR SHALL BE INSTALLED PER
MANUFACTURER RECOMMENDATION
RESILIENT WEDGE ISOLATION VALVE - SIZE PER LINE
STAINLESS STEEL BALL VALVE - SIZE PER LINE
MFG.: LEEMCO FITTINGS (MODEL: LBT-XX-SS)
NOTE: REFER TO SHEET L2.00 FOR
ADDITIONAL DETAILS AND GENERAL NOTES
POINT OF CONNECTION IS A 1" RECLAIMED METER. PRESSURE
READING PROVIDED BY CITY IS 40 PSI AFTER METER.
BOOSTER PUMP - DESIGN/BUILD BY IRRIGATION CONTRACTORBP
2" IRRIGATION MAINLINE - SOLVENT WELD PVC (PURPLE PIPE)
ASTM D2241 - CLASS 200 - SDR 21
MASTER VALVE & FLOW SENSOR
MASTER VALVE: RAINBIRD (MODEL: 200-EFB-CP-PRS-D)
FLOW SENSOR: RAINBIRD (MODEL: FS150B) WITH
SENSOR DECODER (SD210TURF)
INSTALL PER MANUFACTURER RECOMMENDATIONS
SURGE PROTECTOR/GROUNDING PLATE.
MFG.: RAINBIRD SENSOR DECODER (MODEL: LSP-1)
INSTALL EVERY 500' OF CONTROL WIRE OR 10 DECODERS, WHICHEVER IS
LESSER
EARTH GROUND RESISTANCE READINGS TO BE 10 OHMS OR LESS.
RESISTANCE READINGS WILL BE REQUIRED TO BE TESTED BY CONTRACTOR
AND A REPORT VERIFYING READINGS HAVE MET SPECIFICATIONS SUBMITTED
TO OWNER PRIOR TO FINAL PAYMENT BEING RELEASED.
MATCHLINE-SEE SHEET L 2.01
00 20' 40'
IRRIGATION PLAN
L2.02
MATCHLINE-SEE SHEET L 2.01
CYCADIA CEMETERY EAST
(PHASE I)
SEPTEMBER 2019
CITY OF
TARPON SPRINGS
00287-011.01
ANDREW HILL, PLA
LA6667073
PROJECT NO:
DATE:
SHEET NO:
LIC. NO.:
DATE
BY DATEDESCRIPTIONNO.
DESIGNED
DRAWN
Q.C.
APPROVED
CJC, JLG
CJC, JLG
CJC
LA 6667073
STATE
OF
A
N
D
R
E
W
D
.
H
I
L
L
CLEARWATER
380 PARK PLACE BLVD, STE 300, CLEARWATER, FL 33759
TEL: (727) 531 - 3505 FAX: (727) 431 - 1777
www.cardno.com Certificate of Authorization No. 29915
09-20-19
NOTE: CONTRACTOR TO COORDINATE AND
OBTAIN ENCROACHMENT PERMIT PRIOR TO
INSTALLING IRRIGATION WITHIN THE
RIGHT OF WAY ALONG BOTH ROADS. NO
CONSTRUCTION MAY COMMENCE PRIOR TO
OBTAINING THE ENCROACHMENT PERMIT
ALONG E. TARPON SPRINGS AVENUE AND E.
JASMINE AVENUE
GRASS
3" 4"
MULCH OF
PLANT BED
7"
SCALE:
TRENCH EDGING DETAILN.T.S.
4L 3.00
NOTE: USE TRENCH
DETAIL ON ALL SHRUB
BEDS NEXT TO
GRASSED AREAS.
SCALE:
SHRUB & GROUNDCOVER PLANTING DETAILN.T.S.
2L 3.00
SCALE:
TYPICAL TREE STAKING DETAILN.T.S.
1L 3.00
MULTI-STEM TREE
3"-4" EARTH SAUCER
CROWN SPREAD
OVERALL H
EIG
HT
PREPARED PLANTING SOIL
ANY BURLAP AND WIRE
BASKETS CUT OFF OF THE
TOP 3RD OF BALL
60 DEGREE ANGLE
LODGE POLE AT APPROXIMATELY
ROOTBALL OF CONTAINER GROWN
TREE
HOLD MULCH OFF 3" FROM STEMS,
TRUNKS AND ROOT COLLAR
30 INCH V.I.T CINCH STRAP
DOUBLE KNOTTED AROUND
TRUNK
ARBOR TIE - NYLON/POLYESTER
STRAPPING
3 TO 5 TIMES THE WIDTH
OF THE ROOTBALL
3" MULCH PER PLAN
SHRUBS & GROUNDCOVERS
O.C. SPACING
O
.
C
.
S
P
A
C
I
N
G
BED LINE
BACK OF CURB/
TO BE TRIANGULAR SPACING.
ALL SHRUBS/GROUNDCOVER
18" MIN. SETBACK FOR
SEE PLANT LIST FOR (O.C.) SPACING.
HEIG
HT
OF ROOTBALL
3 TO 5 TIMES WIDTH
MULCH 3" FROM STEMS
3" MULCH LAYER
PREPARED PLANTING SOIL
SPREAD
FERTILIZER TABLETS AS SPECIFIED.
PLACE UNIFORMLY AROUND ROOT
MASS BETWEEN MIDDLE AND
BOTTOM OF ROOT MASS
12"
TILLED AND LOOSENED
NATIVE SOIL BACKFILL
NOTE: CONTRACTOR TO
EXCAVATE A MINIMUM 6-18"
BELOW EXISTING GRADE, TO
REMOVE ALL NON-INDIGENOUS
ASPHALT, CONCRETE, AND
LIMEROCK BASE
NOTE: CONTRACTOR TO
EXCAVATE A MINIMUM 6-18"
BELOW EXISTING GRADE, TO
REMOVE ALL NON-INDIGENOUS
ASPHALT, CONCRETE, AND
LIMEROCK BASE
SCALE:
TREE PROTECTION FENCEN.T.S.
3L 3.00
TILLED AND LOOSENED
NATIVE SOIL BACKFILL
LANDSCAPE NOTES
1. ALL PLANTS SHALL BE FLORIDA #1 OR BETTER. ALL PLANTS SHALL BE TYPICAL OF THEIR SPECIES OR
VARIETY AND SHALL HAVE A NORMAL HABIT OF GROWTH. THEY SHALL BE SOUND, HEALTHY AND VIGOROUS,
WELL-BRANCHED AND DENSELY FOLIATED WHEN IN LEAF. THEY SHALL BE FREE OF DISEASE AND INSECT
PESTS, EGGS OR LARVAE. THEY SHALL HAVE HEALTHY, WELL-DEVELOPED ROOT SYSTEMS. ALL PLANTS
SHALL BE GUARANTEED FOR 1 YEAR AFTER FINAL ACCEPTANCE BY OWNER. HEDGE MATERIAL MUST BE
PLANTED 2.5' TO 3' ON CENTER DEPENDING ON THE SPECIES. ALL REQUIRED TREES MUST BE A MINIMUM OF
8' HIGH, 2" CALIPER AT TIME OF PLANTING. ALL HEDGE MUST BE 24" HIGH AT TIME OF PLANTING AND BE
MAINTAINED AT A MINIMUM OF 3' IN HEIGHT.
2. SUBSTITUTIONS: WHEN PLANTS OF A SPECIFIED KIND OR SIZE ARE NOT AVAILABLE, A REASONABLE
SUBSTITUTION MAY BE MADE UPON REQUEST IN WRITING BY THE LANDSCAPE CONTRACTOR, IF APPROVED
BY THE OWNER.
3. AS PER THESE DRAWINGS AND SPECIFICATIONS, THE "HT." (HEIGHT) OF PROPOSED PLANT MATERIALS,
UNLESS OTHERWISE SPECIFIED, SHALL MEAN THE ACTUAL DISTANCE AS MEASURED FROM THE SOIL STRESS
MARK ON TRUNK OR BASE OF PLANT TO THE TOP ELEVATION OF THE PLANT.
4. WORK UNDER THESE SPECIFICATIONS SHALL CONSIST OF PREPARATION OF PLANTING AREA; FURNISHING
AND PLANTING ALL PROPOSED NEW PLANT MATERIALS SPECIFIED HEREIN AND AS SHOWN ON THE
DRAWINGS, INCLUDING BUT NOT LIMITED TO FINISHED GRADING, FURNISHING TOPSOIL, STAKING,
WATERING, PRUNING, FERTILIZING, MULCHING, AND LAYING SOD; AND MAINTENANCE AND PROTECTION OF
PLANTS UNTIL FINAL ACCEPTANCE BY OWNER.
5. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL PLANTS SHOWN ON THE DRAWINGS, AS SPECIFIED, AND
IN QUANTITIES LISTED ON THE PLANT MATERIALS LIST. IN THE EVENT OF A VARIATION BETWEEN THE PLANT
LIST AND THE ACTUAL NUMBER OF PLANTS SHOWN ON THE PLANTING PLAN, THE PLANTING PLAN SHALL
CONTROL.
6. THE OWNER SHALL HAVE THE RIGHT TO REJECT ANY AND ALL WORK AND MATERIALS WHICH, IN THEIR
OPINION, DO NOT MEET THE REQUIREMENTS OF THE PLANTING PLAN, DETAILS, AND THESE SPECIFICATIONS.
7. THE LANDSCAPE CONTRACTOR SHALL STAKE ALL PLANT MATERIAL LOCATIONS FROM THE PLANTING PLAN
PRIOR TO INSTALLATION FOR APPROVAL BY THE OWNER.
8. ALL PLANTING BED AREAS SHALL BE FINE GRADED BY THE LANDSCAPE CONTRACTOR.
9. THE LANDSCAPE CONTRACTOR SHALL EXAMINE THE SOILS OF ALL PLANTING AREAS PRIOR TO PLANTING FOR
THE SUITABILITY TO SUSTAIN HEALTHY PLANT GROWTH AS CALLED FOR ON THE PLANTING PLAN, DETAILS,
AND THESE SPECIFICATIONS.
10. CONTRACTOR TO FINE GRADE AND ROCK-HOUND ALL TURF AREAS PRIOR TO SEEDING AND/OR SODDING, TO
PROVIDE A SMOOTH AND CONTINUAL SURFACE, FREE OF IRREGULARITIES (BUMPS OR DEPRESSIONS) AND
EXTRANEOUS MATERIAL OR DEBRIS.
11. ALL PROPOSED PLANTING AREAS FOR TREES, PALMS, SHRUBS AND GROUNDCOVERS SHALL BE TOP DRESSED
WITH A MINIMUM OF THREE (3) INCHES OF MINI PINE BARK NUGGETS MULCH, SPREAD UNIFORMLY IN DEPTH
OVER THE PLANTING BEDS AS DELINEATED ON THE PLANS UNLESS OTHERWISE NOTED.
12. MULCH SHALL BE ORGANIC AND SHALL BE SPECIFIED IN PLANT BEDS AND AROUND INDIVIDUAL TREES.
WHEN APPLIED TO TREES, MULCH SHALL NOT BE PLACED ON TOP OF THE ROOT BALL OR BE PLACED AGAINST
THE TRUNK. MULCH SHALL BE APPLIED A MINIMUM OF 12" TO 18" FROM THE TRUNK FOR ANY SIZED TREE.
MATERIALS THAT DO NOT BIODEGRADE SUCH AS ROCK AND SHELLS, ARE NOT DEEMED ACCEPTABLE.
FAILURE TO INSTALL MULCH (AND TYPE OF MULCH) AS PROVIDED IN THE SPECIFICATION ABOVE MAY RESULT
IN A FAILED INSPECTION. SEE HTTP://HORT.IFAS.UFL.EDU/WOODY/OVER-MULCHING.SHTML FOR MORE
INFORMATION.
13. ALL PLANTS, UNLESS OTHERWISE SPECIFIED, SHALL BE NURSERY GROWN STOCK, AND SHALL COMPLY WITH
ALL REQUIRED INSPECTIONS, GRADING STANDARDS, PLANT REGULATIONS AND REQUIREMENTS FOR
MEASUREMENT, BRANCHING AND CULTURAL PRACTICES; AS SET FORTH IN THE FLORIDA DEPARTMENT OF
AGRICULTURE "GRADES AND STANDARDS FOR NURSERY PLANTS", (LATEST EDITION), INCLUDING REVISIONS
AS DETERMINED BY THE STATE PLANT BOARD OF FLORIDA OR TO THE STANDARDS AS GIVEN IN THE LATEST
"AMERICAN STANDARD FOR NURSERY STOCK," AMERICAN NATIONAL STANDARDS INSTITUTE.
14. WHERE PROPOSED TREE LOCATIONS OCCUR UNDER EXISTING OVERHEAD UTILITIES OR CROWD EXISTING
TREES, NOTIFY LANDSCAPE ARCHITECT TO ADJUST TREE LOCATIONS.
15. PRIOR TO MOBILIZATION, THE CONTRACTOR SHALL NOTIFY THE OWNER, IN WRITING, IF HE/SHE BELIEVES
ANY OF THE PLANT MATERIAL IDENTIFIED ON THE PLAN MAY NOT BE SUITABLE FOR THE SITE OR MAY DIE.
SUBSTITUTION REQUESTS WILL BE GRANTED BY THE OWNER PRIOR TO THE START OF CONSTRUCTION
ACTIVITIES. IF NOTIFICATION IS NOT GIVEN TO THE OWNER, ALL PLANTING WHICH FAILS TO GROW (EXCEPT
FOR DEFECTS RESULTING FROM LACK OF ADEQUATE MAINTENANCE AS DETERMINED BY THE OWNER,
NEGLECT OR VANDALISM) SHALL BE REPLACED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE.
16. REFER TO PROJECT MANUAL FOR ADDITIONAL REQUIREMENTS.
17. SITE CONDITIONS ARE BASED UPON SURVEY PROVIDED BY OWNER. CONTRACTOR TO FIELD VERIFY
EXISTING CONDITIONS BY DETAILED INSPECTION PRIOR TO SUBMITTING BID AND BEGINNING
CONSTRUCTION.
18. REFER TO CIVIL DRAWINGS FOR ADDITIONAL REQUIREMENTS.
19. REESTABLISH TURF IN AREAS DISTURBED BY GRADING OR UTILITY TRENCHING IN THE RIGHT-OF-WAY.
20. COORDINATE WORK WITH OTHER SITE-RELATED DEVELOPMENT DRAWINGS.
21. ALL LANDSCAPE MAINTENANCE SHALL BE IN ACCORDANCE WITH TARPON SPRINGS STANDARDS. LANDSCAPE
MAINTENANCE PERIOD BEGINS IMMEDIATELY AFTER THE COMPLETION OF ALL PLANTING OPERATIONS AND
WRITTEN ACCEPTANCE FROM THE OWNER AND/OR OWNER'S REPRESENTATIVE. MAINTAIN TREES, SHRUBS,
LAWN AND OTHER PLANTS AS PER THE SPECIFICATIONS. LANDSCAPE MAINTENANCE IS THE LANDSCAPING
CONTRACTORS RESPONSIBILITY UNTIL FINAL ACCEPTANCE BY THE OWNER.
TREES: 3 - 21 GRAM TABLETS EACH 1/2" OF CALIPER
PALMS: 7 - 21 GRAM TABLETS
1 GALLON CAN: 1 - 21 GRAM TABLET
3 GALLON CAN: 2 - 21 GRAM TABLETS
5 GALLON CAN: 3 - 21 GRAM TABLETS
7 GALLON CAN: 4 - 21 GRAM TABLETS
APPLICATION RATE:
FERTILIZATION NOTES
1. THE LANDSCAPE CONTRACTOR SHALL FURNISH FROM HIS SOURCE A GOOD CLEAN, NATIVE SOIL WHICH
SHALL MEET THE APPROVAL OF THE OWNER OR HIS REPRESENTATIVE. THIS SOIL SHALL BE USED FOR THE
PLANTING MIXTURE AS FOLLOWS:
A. ONE PART HILLARY PEAT PLANTING MIX, TOPSOIL OR APPROVED EQUAL
B. ONE PART NATIVE SOIL
2. SOILS WITHIN PLANTING AREAS MUST BE SUITABLE FOR PROPOSED PLANTED MATERIAL & SOD WITH REGARD
TO: pH, SOIL TEXTURE, SOIL STRUCTURE, AND SEASONAL HIGH WATER TABLE. THE CONTRACTOR SHALL
ANALYZE EXISTING SOILS LOCATED IN PROXIMITY TO PROPOSED PLANT MATERIAL AND BE RESPONSIBLE TO
AMEND THE SOIL TO OBTAIN ESSENTIAL REQUIREMENTS NECESSARY FOR THE ESTABLISHMENT AND GROWTH
OF PLANT LIFE. ALSO, THE CONTRACTOR SHALL EXCAVATE A MINIMUM OF 6-18 INCHES BELOW EXISTING
GRADE, SO AS TO REMOVE ALL NON-INDIGENOUS ASPHALT, CONCRETE & LIMEROCK BASE.
SOIL PLANTING MIXTURE (MIX ONSITE)
SHRUBS AND TREES:
ALL TREES AND SHRUBS SHALL BE FERTILIZED WITH "AGRIFORM"
20-15-5 PLANTING TABLETS AT TIME OF INSTALLATION AND PRIOR
TO COMPLETION OF PIT BACKFILLING. TABLETS SHALL BE PLACED
UNIFORMLY AROUND THE ROOT MASS AT A DEPTH THAT IS
BETWEEN THE MIDDLE AND BOTTOM OF THE ROOT MASS.
GROUNDCOVER AREAS:
ALL GROUNDCOVER AREAS SHALL RECEIVE FERTILIZATION WITH
"OSMOCOTE" TIME RELEASE FERTILIZER AS PER
MANUFACTURER'S SPECIFICATIONS.
TREE PROTECTION NOTES
1. DURING LAND ALTERATION AND CONSTRUCTION ACTIVITIES, DO NOT PLACE SOIL DEPOSITS,
DEBRIS SOLVENTS, MACHINERY CONSTRUCTION MATERIAL OF ANY KIND WITHIN THE DRIP LINE OF
A TREE TO REMAIN.
2. BEFORE CONSTRUCTION STARTS ALL PROTECTED TREES SHALL BE PRUNED AS FOLLOWS UNLESS
OTHERWISE DIRECTED BY THE OWNER OR HIS REPRESENTATIVE: REMOVE ANY DEAD OR
DISEASED TRUNKS OR BRANCHES, AND REMOVE WEAK OR CROSSED BRANCHES. ALL CUTS SHALL
BE MADE SUFFICIENTLY CLOSE TO THE TRUNK OR PARENT LIMB, WITHOUT CUTTING INTO THE
BRANCH COLLAR OR LEAVING A PROTRUDING STUB, SO THAT CLOSURE CAN READILY START. ALL
TRIMMING SHALL BE DONE BY A QUALIFIED TREE SURGEON. PRUNING SHALL BE IN ACCORDANCE
WITH ANSI A-300 PRUNING STANDARDS.
3. ALL ROOTS TO BE REMOVED DURING THE SITE CLEARING SHALL BE SEVERED CLEAN AT THE
PERIMETER OF THE DESIGNATED PROTECTED RADIUS. A 3" LAYER OF MULCH SHALL BE
IMMEDIATELY APPLIED OVER THE SURFACE OF EXPOSED ROOTS OF PROTECTED TREES. A SOIL
AUGER WILL BE USED TO BORE UNDER ROOT SYSTEMS IF UTILITIES ARE TO BE INSTALLED WITHIN
10' OF A PROTECTED TREE.
4. CONTACT JOE SAMNIK (727.786.8128), CERTIFIED ARBORIST, #SO - 0408, TRAQ, EXPERT TREE
CONSULTANT, LLC FOR ANY INFORMATION ON EXISTING TREES, TREE INVENTORY AND
EVALUATIONS PERFORMED.
WHEN THE CRITICAL ROOT ZONE WILL BE DISTURBED, AFFECTED ROOTS MUST BE SEVERED BY CLEAN
PRUNING CUTS AT THE POINT WHERE CONSTRUCTION IMPACTS THE ROOTS. ROOTS CAN BE PRUNED BY
UTILIZING TRENCHING EQUIPMENT DESIGNED FOR THIS PURPOSE OR BY HAND DIGGING A TRENCH AND
PRUNING ROOTS WITH A PRUNING SAW, CHAIN SAW OR OTHER EQUIPMENT DESIGNED FOR TREE
PRUNING. ROOTS LOCATED WITHIN A CRITICAL ROOT ZONE THAT WILL BE IMPACTED BY
CONSTRUCTION MUST BE PRUNED TO A DEPTH OF 18 INCHES BELOW THE EXISTING GRADE OR TO THE
DEPTH OF DISTURBANCE IF LESS THAN 18 INCHES FROM THE EXISTING GRADE. WHEN UNDERGROUND
UTILITY LINES ARE TO BE INSTALLED WITHIN THE CRITICAL ROOT ZONE, THE ROOT PRUNING
REQUIREMENTS MAY BE WAIVED IF THE LINES ARE INSTALLED VIA TUNNELING OR DIRECTIONAL BORING
AS OPPOSED TO OPEN TRENCHING. A LICENSED CERTIFIED ARBORIST SHALL PROVIDE PRUNING.
ROOT PRUNING NOTE:
BE ADVISED THAT THE EXISTING UTILITIES ARE NOT SHOWN ON THE LANDSCAPE PLANS FOR GRAPHIC
CLARITY. CONTRACTOR TO REFERENCE SURVEY AND UTILITY PLANS TO VERIFY THAT NO EXISTING
UTILITY LINES ARE CONFLICTING WITH PROPOSED TREE LOCATIONS. IF THESE UTILITY LINES DO
CONFLICT, CONTACT OWNER'S REPRESENTATIVE IMMEDIATELY PRIOR TO ANY CONSTRUCTION
ACTIVITY.
EXISTING UTILITY NOTE:
FERTILIZER TABLETS AS
SPECIFIED. PLACE
UNIFORMLY AROUND
ROOT MASS BETWEEN
MIDDLE AND BOTTOM OF
ROOT MASS
CYCADIA CEMETERY EAST
(PHASE I)
SEPTEMBER 2019
CITY OF
TARPON SPRINGS
00287-011.01
ANDREW HILL, PLA
LA6667073
PROJECT NO:
DATE:
SHEET NO:
LIC. NO.:
DATE
BY DATEDESCRIPTIONNO.
DESIGNED
DRAWN
Q.C.
APPROVED
CJC, JLG
CJC, JLG
CJC
LA 6667073
STATE
OF
A
N
D
R
E
W
D
.
H
I
L
L
CLEARWATER
380 PARK PLACE BLVD, STE 300, CLEARWATER, FL 33759
TEL: (727) 531 - 3505 FAX: (727) 431 - 1777
www.cardno.com Certificate of Authorization No. 29915
09-20-19
PLANTING DETAILS & NOTES
L3.00
POP-UP SPRAY HEAD
SCH. 40 PVC FITTING
ON LATERAL LINE
SCH. 40 PVC STREET ELL
FINISH GRADE
EOP, CURB, WALK OR BEDLINE
POP-UP GEAR ROTOR
SCH. 40 PVC FITTING
SCH. 40 PVC STREET ELL
ON LATERAL LINE
FINISH GRADE
EOP, CURB, WALK OR BEDLINE
4" MULCH LAYER
1/2" INSERT TEE
FINISH GRADE
PVC SUB MAIN
PVC TEE (SxSxT)
3/4" SCH 80 PVC
PVC MAIN LINE
SCH. 40 PVC FITTING
CONTROL WIRES
PVC SCH 80 NIPPLE
3" GRAVEL SUMP
WIRE CONNECTORS
FINISH GRADE
1" REMOTE CONTROL VALVE
STD. RECT. VALVE BOX
1" 200 MESH PRESS. REG. FILTER
NIPPLE
DRIP TUBING
18" MIN.
PVC IPS FLEX PIPE
18" MIN.
PVC IPS FLEX PIPE
STAKE END OF
OF CURB
MARK BACK
CAP END OF SLEEVE
FINISH GRADE
SLEEVE
SLEEVE
PAVEMENT
NOTES:
1. UNLESS OTHERWISE INDICATED, ALL SLEEVES ARE TO
BE PVC SCH 40 AND TWO (2) NOMINAL SIZES LARGER
THAN THE PIPE TO BE SLEEVED. FOR EXAMPLE: THE
SLEEVE FOR A 2" PIPE SHALL BE 3". NO IRRIGATION
SLEEVE SHALL BE SMALLER THAN 2".
2. ALL SLEEVES ARE TO BE INSTALLED WITH A MINIMUM
OF 24" DEPTH OF COVER.
3. ALL SLEEVES TO EXTEND A MINIMUM OF 24" BEYOND
THE EDGE OF PAVEMENT (WHEN POSSIBLE).
4. IDENTIFY ALL SLEEVES LOCATIONS BY STAKING THE
SLEEVE ENDS WITH COLOR CODED BLUE REBAR AND /
OR MARKING THE BACK OF CURB (OR
PAVEMENT)...COORDINATE WITH GENERAL
CONTRACTOR FOR PREFERRED METHOD.
PROVIDE 12" MIN. SPACE BETWEEN ALL
SPRINKLER HEADS AND ANY WALL OR STRUCTURE
BLDG
PAVEMENT
SIDEWALK
E.O.P.
LIGHTPOLE
B.O.C.
ROADWAY
20 GPM MAX.
40 GPM MAX.
JUMBO VALVE BOX
STANDARD VALVE BOX
REMOTE CONTROL
1" FILTER
PVC SCH 80 90 TxT ELL
PVC SCH 80 TOE NIPPLE
PVC SCH 80 MALE ADP.
PVC MAIN LINE
SCH. 40 PVC FITTING
3" GRAVEL SUMP
WIRE CONNECTORS
FINISH GRADE
1.5" REMOTE CONTROL VALVE
STD. RECT. VALVE BOX
(2) 1" 200 MESH PRESS. REG. FILTER
PVC SCH 80 90 TxT ELL
PVC SCH 80 TOE NIPPLE
PVC SCH 80 MALE ADP.
VALVE I.D. TAGVALVE I.D. TAG
3" GRAVEL SUMPPVC MAIN LINE
VALVE PIT
10" ROUND
FINISH GRADE
GATE VALVE
MECH. JOINT
10" PVC SLEEVE
W/ LANDSCAPE FABRIC
CONTROL WIRES
PVC SCH 80 NIPPLE
W/ LANDSCAPE FABRIC
SEE PLAN
1/2-INCH COMPRESSION
PLANT MATERIAL
VARIES
SEE PLAN
VARIES
NOTE:
LOCATE OUTLET OF 1/4"
DISTRIBUTION TUBING ADJACENT
TO ROOT BALL BELOW GRAVEL.
1/2" DIA. BLACK STRIPE TUBING
1/4" DIA. DISTRIBUTION TUBING
TO PLANT ROOTBALL, BELOW
GRAVEL - ON GRADE
PRESSURE-COMPENSATING
EMITTER ON TUBING: RAIN
BIRD BLACK STRIPE TUBING
STAKE TUBING EVERY 3' L.F.
EMITTER (SEE EMITTER SIZING
SCHEDULE & IRRIGATION NOTES
FOR EMITTER SIZE & QTY
SCALE:
20 GPM DRIP ZONE CONTROL VALVEN.T.S.
1 L 3.01
SCALE:
IRRIGATION SLEEVING DETAILN.T.S.
13 L 3.01
NOTE: PROVIDE
12" MIN. SPACE
BETWEEN ALL
DRIPLINES AND
ANY WALL OR
STRUCTURE
SCALE:
PVC - DRIP CONNECTIONN.T.S.
5 L 3.01
SCALE:
GATE VALVE DETAILN.T.S.
10 L 3.01SCALE:
TURF SPRAY HEADN.T.S.
8 L 3.01 SCALE:
TURF ROTOR HEADN.T.S.
9 L 3.01
SCALE:
"AS BUILT" TYPICALN.T.S.
12 L 3.01
SCALE:
BLACK STRIPE TUBINGN.T.S.
6 L 3.01
SCALE:
40 GPM DRIP ZONE CONTROL VALVEN.T.S.
2 L 3.01 SCALE:
DRIP ZONE VALVE - PLAN VIEWN.T.S.
3 L 3.01
FINISH GRADE.
VALVE BOX.
EXTENSION (LENGTH AS
REQUIRED - 24" MIN)
12-14 AWG TWO WIRE
CONTROL WIRE
SCALE:
WIRE SPLICEN.T.S.
7 L 3.01
WATER FLOW
TURF OR MULCH,
REFER TO
LANDSCAPE
MATERIAL SCHEDULE
FOR MORE INFO
3/8" PEA GRAVEL, 4" DEEP - LINE
BOX w/ FILTER FABRIC
STANDARD RECTANGULAR
VALVE BOX w/ OVERLAPPING
LID AND LOCKING BOLT -
SET BOX SO THAT TOP IS
FLUSH w/ TURF FINISH
GRADE OR MULCH
MIN. 10x
PIPE DIAMETER
24
"M
IN
.
MIN. 5x
PIPE DIAMETER
MASTER VALVE PER
IRRIGATION MATERIAL
SCHEDULE
PVC MAIN LINE, SIZE PER PLAN OR
PIPE SIZING SCHEDULE
NOTE:
INLET PIPE LENGTH OF SENSOR MUST BE MIN. 10X
PIPE DIAMETER STRAIGHT, CLEAN RUN OF PIPE, NO
FITTINGS OR TURNS. OUTLET PIPE LENGTH OF
SENSOR MUST BE MIN. 5X PIPE DIAMETER OF
STRAIGHT, CLEAN RUN OF PIPE, NOT FITTINGS OR
TURNS.
FINISH GRADE
10" ROUND VALVE BOX w/
OVERLAPPING LID AND
LOCKING BOLT - SET BOX SO
THAT TOP IS FLUSH w/ TURF
FINISH GRADE OR LAYER OF
ROCK/BARK MULCH
I
N
L
E
T
O
U
T
L
E
T
FLOW SENSOR W/ PE 39
COMMUNICATION CABLE OR
TWO WIRE CABLE TO
IRRIGATION CONTROLLER
SCALE:
MASTER VALVE AND FLOW SENSORN.T.S.
4 L 3.01
SCALE:
SURGE PROTECTORN.T.S.
11 L 3.01
VALVE
NOTES:
1. SURGE DECODER SHOULD BE INSTALLED EVERY 500-FEET.
2. SURGE DECODER TO BE INSTALLED AT END OF WIRE RUN
THAT TERMINATES IN THE FIELD (STAR CONFIGURATION).
FINISH GRADE OR TOP OF MULCH
VALVE BOX WITH COVER:
TO GROUNDING PLATE: 10 OHMS OR LESS.
REFER TO TYPICAL GROUNDING PLATE DETAIL
GREEN/YELLOW WIRE FROM SURGE PROTECTOR
TO GROUNDING PLATE (1 OF 2)
DB SERIES WIRE CONNECTOR:
3M DBY/DBR-6
LINE SURGE PROTECTOR
TWO-WIRE CABLE TO NEXT DEVICE (FIELD
DECODER, SENSOR DECODER, LINE SURGE
PROTECTOR OR CONTROLLER)
COMMUNICATION WIRE TO NEXT DEVICE (FIELD
DECODER, SENSOR DECODER, LINE SURGE
PROTECTOR OR CONTROLLER)
3-INCH MINIMUM DEPTH OF 3/4-INCH WASHED
GRAVEL
BRICK (1 OF 2)
BLUE WIRE FROM SURGE PROTECTOR TO DB
SERIES WIRE CONNECTOR
PROVIDE 12" MIN. SPACE BETWEEN ALL
SPRINKLER HEADS AND ANY WALL OR STRUCTURE
PREFORMED SUPER
SERVISEAL WATERPROOF
WIRE SPLICE KIT
3M DBY/DBR-6 CONNECTORS
(SPLICE ALL WIRE PAIRS)
CYCADIA CEMETERY EAST
(PHASE I)
SEPTEMBER 2019
CITY OF
TARPON SPRINGS
00287-011.01
ANDREW HILL, PLA
LA6667073
PROJECT NO:
DATE:
SHEET NO:
LIC. NO.:
DATE
BY DATEDESCRIPTIONNO.
DESIGNED
DRAWN
Q.C.
APPROVED
CJC, JLG
CJC, JLG
CJC
LA 6667073
STATE
OF
A
N
D
R
E
W
D
.
H
I
L
L
CLEARWATER
380 PARK PLACE BLVD, STE 300, CLEARWATER, FL 33759
TEL: (727) 531 - 3505 FAX: (727) 431 - 1777
www.cardno.com Certificate of Authorization No. 29915
09-20-19
IRRIGATION DETAILS
L3.01
PVC SWEEP ELL
(1 1/2" OR LARGER)
6 AWG SOLID BARE
COPPER WIRES
GROUND PLATE
EARTH CONTACT
MATERIAL
ELECTRODE
SPHERE OF
INFLUENCE
BOUNDARIES *
COPPER GROUND PLATE
(4" X 96" X .0625")
* DO NOT INSTALL ANY OTHER WIRES OR CABLE
WITHIN THE SPHERE OF INFLUENCE
CONTROLLER
CONCRETE PAD
#6 AWG SOLID
BARE COPPER WIRE
#6 AWG SOLID
BARE COPPER WIRE
CONTROLLER
CONCRETE PAD
MIM. 8' FROM CONT.
MINIMUM ACCEPTABLE RESISTANEC TO GROUND IS 25 OHMS.
USE ADDITIONAL GROUND PLATES OR GROUND RODS AS NEEDED.
SCALE:
CONTROLLER GROUNDINGN.T.S.
2 L 3.02
TOP VIEW
SIDE VIEW
GROUND PLATE
GROUND PLATE
L
3L
3W
W
for the latest rev. go to
http://www.asic.org/design_guides.htm
EARTH CONTACT
MATERIAL
GROUND PLATE
6 AWG SOLID BARE
COPPER WIRES
30" MIN. *
VALVE BOX
COPPER GROUND PLATE
(4" X 96" X .0625")
12"
8'
8'
#6 AWG SOLID
BARE COPPER WIRE ELECTRODE
SPHERE OF
INFLUENCE
BOUNDARIES
DO NOT INSTALL ANY OTHER WIRES OR CABLE
WITHIN THE SPHERE OF INFLUENCE
* OR BELOW FROSTLINE, WHICHEVER IS DEEPER
SIDE VIEW
DO NOT INSTALL ANY OTHER WIRES OR CABLE
WITHIN THE SPHERE OF INFLUENCE
NOTE: INSTALL EVERY 500' OF CONTROL WIRE OR 10 DECODERS, WHICHEVER IS LESS.
EARTH GROUND RESISTANCE READINGS TO BE 10 OHMS OR LESS. RESISTANCE
READINGS WILL BE REQUIRED TO BE TESTED BY CONTRACTOR AND A REPORT SUBMITTED
TO CARDNO PRIOR TO FINAL PAYMENT BEING RELEASE.
AMERICAN SOCIETY OF IRRIGATION CONSULTANTS COPYRIGHT 2001
SCALE:
TYPICAL GROUNDING PLATEAND SPHERES OF INFLUENCE
N.T.S.
3 L 3.02
BRICK OR CONC. BLOCK
CLASS 200 MAINLINE
STANDARD RECTANGULAR VALVE BOX
FINISH GRADE
NOTES:
1. PVC PIPE & FITTINGS UPSTREAM OF THE
ISOLATION VALE TO BE THE SAME AS
SIZE THE MAINLINE.
2. ISOLATION VALVE SAME SIZE AS REMOTE
CONTROL VALVE.
3. ONE VALVE PER STANDARD
RECTANGULAR VALVE BOX
DRAIN ROCK WITH LANDSCAPE FABRIC.
MIN. 3" DEEP AND 2" BELOW BOTTOM
OF PIPE
NOTES:
1. MAXIMUM LENGTH OF SECONDARY WIRE PATH (14 AWG)
FROM FIELD DECODER TO SOLENOID IS 450 FEET.
2. PLACE 3 FEET OF EXTRA WIRE IN EVERY VALVE BOX FOR
EASIER SERVICING.
3. ALL WIRE CONNECTIONS SPLICED WITH DIRECT BURY SPLICE
KIT (3M DBY/DBR-6) CONNECTORS.
COMMUNICATION
WIRE TO NEXT
DEVICE (FIELD
DECODER, SENSOR
DECODER, LINE
SURGE PROTECTOR
OR CONTROLLER)
TWO-WIRE CABLE TO
NEXT DEVICE (FIELD
DECODER, SENSOR
DECODER, LINE SURGE
PROTECTOR OR
CONTROLLER)
FIELD DECODER
DB SERIES WIRE
CONNECTOR:
3M DBY/DBR-6
(1 OF 4)
SOLENOID WIRE (1 OF 2)
SCALE:
VALVE AND DECODER DETAILN.T.S.
1L 3.02
1. CONTRACTOR TO VERIFY WITH OWNER AND UTILITY COMPANIES THE LOCATIONS OF ALL UTILITIES
PRIOR TO CONSTRUCTION AND TO DETERMINE IN THE FIELD THE ACTUAL LOCATIONS AND
ELEVATIONS OF ALL EXISTING UTILITIES WHETHER SHOWN ON THE PLAN OR NOT. THE
CONTRACTOR SHALL CALL UTILITY PROTECTION SERVICE 72 HOURS PRIOR TO CONSTRUCTION.
2. CONTRACTOR TO REPORT ALL DAMAGES TO EXISTING CONDITIONS OR INCONSISTENCIES WITH
PLANS TO LANDSCAPE ARCHITECT.
3. CONTRACTOR SHALL EXAMINE FINISH SURFACE, GRADES, TOPSOIL QUALITY AND DEPTH. DO NOT
START ANY WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. VERIFY LIMITS
OF WORK BEFORE STARTING.
4. CONTRACTOR SHALL COORDINATE IRRIGATION INSTALLATION WITH INSTALLATION OF
LANDSCAPING, WALL CONSTRUCTION AND DRAINAGE SYSTEMS. IRRIGATION CONTRACTOR WILL
BE RESPONSIBLE FOR COORDINATION WITH OTHER SUBCONTRACTORS FOR INSTALLATION OF
UNDERGROUND SLEEVING.
5. ALL PRODUCTS SHALL BE INSTALLED PER THE MANUFACTURER'S RECOMMENDATIONS AND
ACCORDING TO TO LOCAL BUILDING, ELECTRICAL, AND PLUMBING CODES.
6. IF REQUIRED, THE IRRIGATION CONTRACTOR SHALL PROVIDE THE NECESSARY "RIGHT OF WAY"
ENCROACHMENT PERMITS.
7. PRIOR TO BACKFILLING TRENCHES CONTACT LANDSCAPE ARCHITECT TO VERIFY WIRE PATH
ROUTING, CONTROLLER WIRE AND SPLICING CONNECTIONS.
8. LAYOUT OF THE SYSTEM AS SHOWN ON DRAWINGS IS DIAGRAMMATIC. IRRIGATION LINES SHOWN
WITHIN PAVED AREAS ARE FOR GRAPHIC CLARITY ONLY. IRRIGATION HEADS AND PIPES ARE TO BE
PLACED WITHIN LANDSCAPED AREAS WITH THEIR LOCATIONS MODIFIED AS REQUIRED TO AVOID
PLANT MATERIALS, UTILITIES AND OTHER OBSTRUCTIONS.
9. IRRIGATION CONTRACTOR SHALL COMPLY WITH PIPE SIZES AS INDICATED.
10. PIPE UP TO 1-1/2" DIAMETER MAY BE PULLED WITH A VIBRATORY PLOW EQUAL TO A DITCH WITCH
255. PIPING FROM 2" T0 2-1/2" DIAMETER SHALL BE PULLED WITH A MACHINE LARGER OR EQUAL
TO A DITCH WITCH R-40. TRENCH ALL PIPE OVER 2-1/2" DIAMETER. CONTRACTOR HAS THE OPTION
TO TRENCH ALL PIPE.
11. THE MAINLINE IS TO BE INSTALLED WITH A MINIMUM OF 24" DEPTH OF COVER. ALL LATERAL LINES
ARE TO BE INSTALLED WITH A MINIMUM OF 12" DEPTH OF COVER.
12. THE IRRIGATION DISTRIBUTION MAINLINE SHALL BE INSTALLED PER CITY OF TARPON SPRINGS
WATER STANDARDS.
13. CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING ALL SLEEVING FOR THE PROJECT. ALL
SLEEVES ARE TO BE PVC SCH 40 AND TWO (2) NOMINAL SIZES LARGER THAN THE PIPE TO BE
SLEEVED. FOR EXAMPLE: THE SLEEVE FOR A 2" PIPE SHALL BE 3". NO IRRIGATION SLEEVE SHALL
BE SMALLER THAN 2".
14. WHEREVER PRACTICAL, INSTALL VALVES IN MULCHED BEDS AND/OR OUT OF HIGH TRAFFIC
AREAS. IF INSTALLED IN TURF AREA, VALVE BOX TO BE A MINIMUM OF 48" FROM BED EDGE. ONE
VALVE PER VALVE BOX. ALL VALVES , FLUSH VALVES AND WIRE SPLICES SHALL BE INSTALLED IN
RAIN BIRD WIDE FLANGED, STRUCTURAL FOAM "PLASTIC" VALVES BOXES WITH LIDS AS FOLLOWS:
REMOTE CONTROL VALVES #VB-STD, 12" STD. RECT. BOX
ISOLATION GATE VALVES #VB-10RND, 10" ROUND BOX
WIRE SPLICES #VB-10RND, 10" ROUND BOX
DRIP ZONE VALVE / FILTER ASSY #VB-SPR, SUPER JUMBO RECT. BOX
15. LOCATE VALVE MANIFOLDS IN CLOSE PROXIMITY FOR EASE OF MAINTENANCE, BUT NOT CLOSER
THAN 4'-0" BETWEEN VALVE BOXES.
16. ALL POP-UP SPRINKLER HEADS AND ROTORS SHALL BE INSTALLED LEVEL AND FLUSH TO GRADE.
17. LOCATION OF ALL SPRINKLER HEADS SHALL BE SITE ADJUSTED TO MINIMIZE WATER OVERTHROW
ONTO BUILDING SURFACES AND WALKWAYS. THROTTLE VALVES ON SPRAY ZONES AS REQUIRED
TO PREVENT FOGGING. USE LOW TRAJECTORY NOZZLES WHENEVER POSSIBLE. ALL SPRINKLER
HEADS SHALL BE INSTALLED PERPENDICULAR TO FINISH GRADES EXCEPT AS OTHERWISE
INDICATED.
18. PROTECT IRRIGATION CONTROL EQUIPMENT UNIT FROM DAMAGE AFTER INSTALLATION AND UNTIL
FINAL ACCEPTANCE. THE UNIT SHALL BE IN BRAND NEW CONDITION WHEN FULL OPERATION OF
THE SYSTEM IS TURNED OVER TO THE OWNER AFTER FINAL ACCEPTANCE. THE CONTRACTOR
SHALL, AT THEIR OWN EXPENSE, REPLACE ALL OR PART OF THE UNIT THAT IS DAMAGED AND
UNACCEPTABLE TO THE OWNER.
19. INSTALL DRIP TUBING AT GRADE AND COVER WITH MULCH. TYPICAL SPACING FOR DRIP TUBING IS
18" TO 24" ON CENTER. SPACING TO BE DETERMINED BY SOIL TYPE. ANCHOR TUBING EVERY 7'
WITH 8" LONG WIRE TUBING STAKES.INSTALL FLUSH VALVE ASSEMBLIES AT ALL TUBING "DEAD
ENDS".
20. EXACT CONTROLLER LOCATION(S) SHALL BE COORDINATED WITH AN OWNER'S REPRESENTATIVE
PRIOR TO INSTALLATION. UNLESS OTHERWISE STATED, THE GENERAL CONTRACTOR SHALL
PROVIDE 110 VOLT POWER TO THE CONTROLLER LOCATION(S). THE IRRIGATION CONTRACTOR IS
RESPONSIBLE FOR THE CONNECTION FROM THE POWER SOURCE TO THE CONTROLLER(S).
INSTALL LEVEL AND PLUMB ON COMPACTED SUBSOIL AND BASE ROCK AS SHOWN ON DRAWINGS.
21. IRRIGATION CONTRACTOR SHALL PROVIDE POWER AND WATER FOR ALL LANDSCAPE ELEMENTS TO
PROVIDE AN OPERATING IRRIGATION SYSTEM, INCLUDING CONTROLLER. IRRIGATION
CONTRACTOR TO PROVIDE AND INSTALL ELECTRICAL CONDUITS AND WIRING TO PROVIDE POWER
FROM ELECTRICAL BRANCH PANEL TO THE IRRIGATION CONTROL EQUIPMENT UNIT, COORDINATE
WITH LANDSCAPE CONTRACTOR. IRRIGATION CONTRACTOR WILL BE RESPONSIBLE TO
COORDINATE WITH AN ELECTRICIAN AS NEEDED.
22. AT EACH IRRIGATION CONTROLLER, INSTALL A "SECONDARY SURGE ARRESTER" TO THE INCOMING
(120 VOLT) POWER SUPPLY (INTERMATIC #AG2401 OR EQUAL).
23. AT EACH IRRIGATION CONTROLLER, INSTALL AN "EARTH GROUND GRID" WITH A MINIMUM OF TWO
(2) 4" X 96" GROUNDING PLATES. TEST THE RESISTANCE TO EARTH PER NFPA STANDARD #780. A
ACCEPTABLE EARTH GROUND SHOULD HAVE 10 OHMS OR LESS RESISTANCE. USE MORE PLATES OR
GROUNDING RODS AS NEEDED TO ACHIEVE THE DESIRED RESISTANCE READING.
24. THE WIRELESS RAIN SHUTOFF DEVICE SHALL BE INSTALLED TO MEET LOCAL CODES AND/OR
MINIMUM MANUFACTURER'S RECOMMENDATIONS. OBSTRUCTIONS, VANDALISM AND EASE OF
SERVICE SHALL BE CONSIDERED IN LOCATING THE DEVICE. DO NOT LOCATE IN AN AREA
SHELTERED FROM RAIN.
25. THE IRRIGATION CONTRACTOR SHALL PREPARE AN AS-BUILT DRAWING ON REPRODUCIBLE PAPER
DETAILING THE ACTUAL INSTALLATION OF THE IRRIGATION SYSTEM. THE AS-BUILT DRAWINGS
SHALL LOCATE ALL MAIN LINE PIPING, CONTROL WIRES, WIRE SPLICES, SLEEVES AND VALVES BY
SHOWING EXACT MEASUREMENTS FROM PERMANENT FEATURES (BUILDINGS, EDGE OF PAVEMENT,
POWER POLES, FIRE HYDRANTS, ETC.). INCLUDE DEPTH OF COVER ON MAINLINE AND SLEEVES.
FINAL APPROVAL WILL NOT BE GIVEN WITHOUT A SUBMITTED AND APPROVED AS-BUILT.
26. IRRIGATION CONTRACTOR SHALL PROVIDE A COLOR CODED MAP OF THE AREA SERVED BY EACH
CONTROLLER, SEALED IN PLASTIC OR LAMINATED, AND PLACE IT IN EACH CONTROLLER BOX UPON
FINAL ACCEPTANCE.
27. ANY OTHER EQUIPMENT REQUIRED THAT IS NOT OTHER WISE DETAILED OR SPECIFIED SHALL BE
INSTALLED AS PER MANUFACTURER'S RECOMMENDATIONS AND LOCAL CODE IN ORDER TO
PROVIDE A COMPLETE AND OPERABLE SYSTEM.
28. ALL IRRIGATION SYSTEMS SHALL BE OPERATED AND MAINTAINED IN ACCORDANCE TO THE
PINELLAS COUNTY STANDARDS.
29. INSTALL TRACING WIRE OVER ALL MAINLINE PIPE AND CONTROLLER WIRE (INCLUDING) WIRE
WHICH IS NOT INSTALLED IN TRENCH WITH PIPE.
30. CONTRACTOR TO PROVIDE OWNER WITH KEYS AND HOSE SWIVELS FOR EACH QUICK COUPLER
VALVE.
31. CONTRACTOR SHALL OBTAIN WRITTEN APPROVAL FOR ALL PRODUCT SUBSTITUTIONS BY THE
LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. PRODUCTS, MANUFACTURERS, AND MODELS
NOT IN COMPLIANCE WITH DRAWINGS AND SPECIFICATIONS MAY BE REJECTED BY THE LANDSCAPE
ARCHITECT WITHOUT PRIOR WRITTEN APPROVAL. AT NO COST TO THE OWNER THESE ITEMS MAY
BE REQUIRED TO BE REPLACED WITH PRODUCTS THAT ARE IN COMPLIANCE WITH THE
MANUFACTURERS AND MODELS ON THE IRRIGATION PLAN.
32. PROVIDE AND INSTALL CONDUIT SWEEPS AND STRAIGHT SECTIONS FROM IRRIGATION TRENCHES
TO THE CONTROLLER. ROUTE CONTROL WIRE THROUGH CONDUITS INTO CONTROLLER CABINET.
NEATLY CONNECT WIRES TO TERMINAL STRIPS PROVIDED IN THE CONTROLLER CABINET.
34. ALL WIRE SPLICES OR CONNECTIONS SHALL BE MADE WITH APPROVED WATERPROOF WIRE
CONNECTIONS AND BE IN A VALVE OR SPLICE BOX.
35. IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR ADJUSTING THE RUN TIMES SO THAT TURF
AND PLANTS ARE NOT OVER-WATERED, AND SHALL BE RESPONSIBLE FOR KEEPING THE SITE FREE
OF STANDING WATER.
36. SET AND UTILIZE CONTROLLER TO WATER NEW PLANTINGS FOR THE DURATION OF THE PROJECT
UNTIL FINAL ACCEPTANCE.
37. IRRIGATION CONTRACTOR WILL ARRANGE INSPECTIONS REQUIRED BY LOCAL AGENCIES &
ORDINANCES DURING THE COURSE OF CONSTRUCTION AS REQUIRED. ALL PRODUCTS, WIRING
AND BACKFLOW PREVENTER TO BE INSTALLED IN ACCORDANCE WITH LOCAL AND STATE PLUMBING
CODES
38. ALL CONTROL WIRING DOWNSTREAM OF THE CONTROLLER IS TO BE 2-WIRE, UL APPROVED DIRECT
BURY.
39. THE INSTALLING CONTRACTOR MUST HOLD A CURRENT, VALID FLORIDA IRRIGATION
CONTRACTOR'S LICENSE.
40. THE DESIGN IS BASED ON SITE INFORMATION AND /OR DRAWING SUPPLIED WITH THE DESIGN
CRITERIA BEING SET (AREA TO BE IRRIGATED, EQUIPMENT MANUFACTURER AND MODEL TO BE
USED, WATER SOURCE INFORMATION. ELECTRICAL POWER AVAILABILITY, ETC...) CARDNO BEARS
NO RESPONSIBILITY OR LIABILITY FOR ANY ERRORS IN DESIGN OR INSTALLATION THAT ARISE DUE
TO INACCURACIES IN THE ABOVE REFERENCED INFORMATION SUPPLIED TO CARDNO IN RELATION
TO THIS PROJECT, UNLESS OTHERWISE NOTED.
REMOTE CONTROL VALVE WITH 18"
COIL OF WIRE & MALE REDUCER
CENTERED IN OPENING
PVC SCH 80 90 TxT ELL
PVC SCH 80 TOE NIPPLE
VALVE ID TAG
PVC SCH 80 NIPPLE
PVC SCH 40 FITTING
TOP VIEW
IRRIGATION NOTES
CYCADIA CEMETERY EAST
(PHASE I)
SEPTEMBER 2019
CITY OF
TARPON SPRINGS
00287-011.01
ANDREW HILL, PLA
LA6667073
PROJECT NO:
DATE:
SHEET NO:
LIC. NO.:
DATE
BY DATEDESCRIPTIONNO.
DESIGNED
DRAWN
Q.C.
APPROVED
CJC, JLG
CJC, JLG
CJC
LA 6667073
STATE
OF
A
N
D
R
E
W
D
.
H
I
L
L
CLEARWATER
380 PARK PLACE BLVD, STE 300, CLEARWATER, FL 33759
TEL: (727) 531 - 3505 FAX: (727) 431 - 1777
www.cardno.com Certificate of Authorization No. 29915
09-20-19