drawings.pdf · the contractor shall be responsible for all electrical work ... 5.contractor shall...
TRANSCRIPT
SAN JOSE
EVERGREEN VALLEY COLLEGE
COMMUNITY DISTRICT
ISSUANCE:PROJECT NO:16.029
DATE: 05/15/2017
DRAWN | CHECKED:CADD | NA
SHEET NO:
SCALE:
SHEET:
PROJECT:
100% CONSTRUCTION DOCUMENTATION -PACKAGE #2
CAMPUS WAYFINDING SIGNAGE
REVISION:
4 05/15/17 CCD-01
N
IDENTIFICATION STAMP
DIVISION OF THE STATE ARCHITECT
OFFICE OF REGULATION SERVICES
FILE NO.
APPL. NO.
AC FLS SS
DATE
________
________
43-C1
01-116103
Digital Message Sign
60 Garden Court Suite 210 Monterey, CA 93940
T.831.646.3330 F.831.646.3336 www.acemb.com
Project No.
ONTEREY
NGINEERS
ONSULTING
E
M
URUM A C
AY, INC.B
THE USE OF THE PLANS AND SPECIFICATIONS IS RESTRICTED TO THE
ORIGINAL SITE FOR WHICH THEY WERE PREPARED, AND PUBLICATION
THEREOF IS EXPRESSLY LIMITED TO SUCH USE. REUSE, REPRODUCTION OR
PUBLICATION BY ANY METHOD IN WHOLE OR IN PART IS PROHIBITED. TITLE
TO THE PLANS AND SPECIFICATIONS REMAINS WITH AURUM CONSULTING
ENGINEERS, INC., AND VISUAL CONTACT WITH THEM CONSTITUTES PRIMA
FACIE EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS.
16086.00
E0.1A
SYMBOLS & GENERAL
CONSTRUCTION NOTES
NO SCALE
SHEET INDEX (CCD-01)
E0.1A SYMBOLS & GENERAL
CONSTRUCTION NOTES.
E0.2 CODES, STANDARDS,
EQUIPMENT ANCHORAGE &
DEMOLITION NOTES.
E2.0A OVERALL SITE PLAN.
E2.1A PARTIAL SITE PLAN.
E2.5 PARTIAL SITE PLAN -
FACILITIES SHOP BLDG.
E3.0 ELECTRICAL DETAILS.
GENERAL CONSTRUCTION NOTES
1. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES AND REGULATIONS. MATERIALS AND
EQUIPMENT SHALL BE U.L. LISTED AND LABELED FOR THE APPLICATION.
2. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES AND INSPECTION FEES
REQUIRED BY THIS CONTRACT WORK.
3. CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO BIDDING AND ALLOW FOR ALL FIELD
CONDITIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ELECTRICAL WORK NOTED AND
CALLED OUT ON ALL CONTRACT DOCUMENTS. THE CONTRACTOR SHALL OBTAIN INFORMATION AND
BE FAMILIAR WITH ALL OTHER TRADES WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATION BETWEEN OTHER TRADES ON PROJECT.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF PERSONS AND PROPERTY AND SHALL
PROVIDE INSURANCE COVERAGE AS NECESSARY FOR LIABILITY AND PERSONAL, PROPERTY
DAMAGE, TO FULLY PROTECT THE OWNER, ARCHITECT AND ENGINEER FROM ANY AND ALL CLAIMS
RESULTING FROM THIS WORK.
5. CONTRACTOR SHALL MAINTAIN RECORD DRAWINGS AT THE PROJECT SITE INDICATING ALL
MODIFICATIONS TO ELECTRICAL SYSTEMS. THE CONTRACTOR SHALL AT THE CONCLUSION OF THE
PROJECT PROVIDE ACCURATE "AS-BUILT" DRAWINGS ACCEPTABLE TO THE ARCHITECT.
6. ALL MATERIALS PROVIDED TO THE PROJECT SHALL BE NEW. THE CONTRACTOR SHALL BE
RESPONSIBLE TO PROVIDE AND INSTALL ALL INCIDENTAL MATERIALS REQUIRED FOR A COMPLETE
INSTALLATION.
7. CONTRACTOR SHALL PROVIDE TO THE ARCHITECT A CONSTRUCTION SCHEDULE OF ELECTRICAL
WORK. THE CONSTRUCTION SCHEDULE SHALL IDENTIFY ALL SIGNIFICANT MILESTONES WITH
COMPLETION DATES.
8. CONTRACTOR SHALL PROVIDE ALL REQUIRED "CUTTING, PATCHING, EXCAVATION, BACKFILL AND
REPAIRS" NECESSARY TO RESTORE DAMAGED SURFACES TO EQUAL OR BETTER THAN ORIGINAL
CONDITIONS EXISTING AT START OF WORK.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR PAINTING ALL EXPOSED CONDUITS AND ELECTRICAL
EQUIPMENT. REFER TO ARCHITECTS PAINTING SECTION FOR REQUIREMENTS.
10. ALL ELECTRICAL EQUIPMENT INSTALLED OUTDOORS SHALL BE WEATHERPROOF. EXTERIOR
CONDUITS RUN INTO BUILDINGS SHALL BE INSTALLED WITH FLASHING, CAULKED AND SEALED.
CONDUITS FOR EXTERIOR ELECTRICAL DEVICES SHALL BE RUN INSIDE BUILDING UNLESS
OTHERWISE NOTED ON DRAWINGS.
11. ALL CONDUITS UNLESS OTHERWISE NOTED ON DRAWINGS SHALL HAVE AS A MINIMUM: TWO (2) #12s
WITH ONE (1) #12 GROUND. "TICK" MARKS SHOWN ON CIRCUITRY ARE FOR ROUGH ESTIMATING
ONLY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WIRES AND WIRE SIZES REQUIRED BY
LATEST CODE.
12. ALL BRANCH CIRCUITS SHALL HAVE INDIVIDUAL NEUTRALS. SHARED NEUTRALS ON MULTIWIRE
CIRCUITS IS NOT ALLOWED.
13. COORDINATE ALL CONDUIT RUNS, ELECTRICAL EQUIPMENT AND PANELS WITH ALL OTHER WORK TO
AVOID CONFLICTS.
14. CONTRACTOR SHALL PROVIDE IN EVERY NEW EMPTY CONDUIT A DRAW STRING FOR USE IN FUTURE
CONSTRUCTION.
15. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGE TO (E) UNDERGROUND SYSTEMS (GAS,
WATER, TELEPHONE, ELECTRICAL, SEWER, ETC.). THE CONTRACTOR SHALL REPAIR & PAY ALL
EXPENSES FOR DAMAGE TO (E) UNDERGROUND SYSTEMS AS A RESULT OF (N) WORK. REPAIR TO
DAMAGED UNDERGROUND SYSTEMS SHALL BE TO THE OWNERS SATISFACTION WITHOUT EXTRA
EXPENSE TO THE OWNER.
16. EXISTING WIRING SHOWN HAS BEEN TAKEN FROM OLD PLANS AND IS ASSUMED TO BE CORRECT.
ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ACTUAL CONDITIONS AND MAKE ADJUSTMENTS TO
SUIT ACTUAL CONDITIONS AND TO MEET THE INTENT OF THE CONTRACT DOCUMENTS.
17. ALL INSTALLATION OF EXPOSED SURFACE MOUNTED RACEWAY IN PUBLIC AREAS SHALL BE
REVIEWED BY ELECTRICAL ENGINEER BEFORE ROUGH-IN. CONTRACTOR IS TO DETERMINE THE
ACCESSIBILITY OF ATTIC, FURRED SPACE, HOLLOW MULLIONS, ETC. IN EACH AREA AND REVIEW
WITH ENGINEER. IF SYSTEM CAN BE ROUTED CONCEALED EITHER BY FISHING OR ACCESSIBILITY,
CONTRACTOR IS TO DO SO. IF INACCESSIBILITY IS DETERMINED, CONTRACTOR SHALL INSTALL
SURFACE MOUNTED RACEWAY IN THE MOST AESTHETICALLY PLEASING MEANS AS DETERMINED BY
THE THE ENGINEER. NO ALLOWANCE FOR ADDITIONAL COMPENSATION DUE TO ROUTING AS
DIRECTED BY THE ENGINEER WILL BE MADE.
#10
T
TV
E
2
3
J
SIZE PER CODE, TAPE AND TAG WIRES
METER W/ CURRENT TRANSFORMER
JUNCTION BOX - CEILING OR WALL MOUNTED,
PER EQUIPMENT MFGRS NAMEPLATE DATA
FUSED DISCONNECT SWITCH ELEMENT FUSES SIZED
CONDUIT - UP
CONDUIT - DOWN
CONDUIT - TELEVISION
CONDUIT EMERGENCY SYSTEM
FLEX CONDUIT WITH CONNECTION
CONDUIT - TELEPHONE
SURFACE METAL OR NON-METALLIC RACEWAY
CONDUIT - CONCEALED IN WALLS OR CEILING
CONDUIT - EXISTING
CONDUIT - BELOW SLAB OR
UNDERGROUND: 3/4"MIN.
CONDUIT - HOME RUN TO PANEL, TERMINAL CABINET,
ETC. RUNS MARKED WITH CROSSHATCHES INDICATE
NUMBER OF #12 AWG WIRES WHEN MORE THAN TWO.
SIZE CONDUIT ACCORDING TO SPECIFICATIONS AND
APPLICABLE CODE. CROSS HATCHES WITH NUMBER
ADJACENT INDICATES WIRE SIZE OTHER THAN #12AWG.
GROUND ELECTRODE
NEMA 3R ENCLOSURE UNLESS OTHERWISE SPECIFIED
MAGNETIC STARTER - NEMA SIZE INDICATED
NON-FUSED DISCONNECT SWITCH
GROUND ROD WITH GROUNDWELL BOX
CIRCUIT BREAKER
NORMALLY CLOSED CONTACT
NORMALLY OPEN CONTACT
TRANSFORMER - SEE SINGLE LINE FOR SIZE
MOTOR CONNECTION
COMBINATION STARTER/FUSED DISCONNECT SWITCH;
CONDUIT CONTINUATION
DETAIL REFERENCE
CAPPED OR STUB-OUT CONDUIT
PULLBOX
SYMBOLS & ABBREVIATIONS SHOWN ARE FOR GENERAL USE. DISREGARD THOSE WHICH DO NOT APPEAR ON THE PLANS.
2
1
E3.0
M
LOW VOLTAGE WIRINGLV
1
2
F301
HEIGHTHT
INTERCOM
PANEL
LIGHTING
KILOWATT
KILOVOLT
JUNCTION BOX
LIGHTING CONTROL
KILOVOLT
KVA
LCP
LTG
JB
KW
KV
KILOVOLT AMPERES
FUSED DISCONNECT SWITCH; FUSED WITH
DUAL-ELEMENT FUSES SIZED PER EQUIPMENT
MFGR'S NAMEPLATE DATA
IC
INCANDESCENTINCAND
INTERMEDIATE IDF
DETAIL NUMBER
SHEET NUMBER
DISTRIBUTION FRAME
ELECTRICAL SYMBOLS & ABBREVIATIONS
J
PULL BOXPB
PA PUBLIC ADDRESS
CHLORIDE
POLYVINYL
REQUIRED
REMOVED
SHEET
SWITCH
PHASE
PANEL
PVC
PNL
REQD
SWBD
SHT
(R)
SW
PF
NOTED
WITH
WATT
VOLT
UON
XFMR
W/
W
WP
V
TYP TYPICAL
MOUNTED
METAL HALIDE
THOUSAND
LOW VOLTAGE
CIRCULAR MILS
MAIN LUGS ONLY
NEW
NOT IN CONTRACT
ON CENTER
CONTRACT
NOT IN ELECTRICAL
MOUNTING
POWER FACTOR
SWITCHBOARD
UNLESS OTHERWISE
REQUIREMENT(S)
EXISTING TO BE
TRANSFORMER
WEATHERPROOF
MTD
KCM
LV
MH
MLO
OC
NIEC
NIC
(N)
MTG
OVERHEADOH
REQMT'S
MECHANICALMECH
RECPT'S RECEPTACLES
(RP) REMOVABLE POLE
PWR POWER
UG UNDERGROUND
SINGLE LINE DIAGRAMSLD
OAH OVERALL HEIGHT
PASSIVE INFRAREDPIR
PH
PHOTOVOLTAICPV
TTB TELEPHONE TERMINAL
BACKBOARD
MAIN DISTRIBUTIONMDF
MAIN POINT OFMPOE
FRAME
ENTRANCE
SYSTEMS TERMINATION
CABINET
STC
FUTURE
GROUND FAULT
GROUND
INTERRUPTING
GFCI
(F)
A.F.F.
A
ABOVE FINISHED
AMPERE
GND, G
AWG
ARCH
BKR
CB
CO
CLG
CTR
CKT
DIM
DIST
CL
(E)
C
EQUIP
FIN
FACP
FA
FL
EMT
FLOOR
METALLIC TUBING
CONTROL PANEL
EQUIPMENT
FIRE ALARM
FINISH
FIRE ALARM
AMERICAN WIRE
CIRCUIT BREAKER
BREAKER
GAUGE
DISTRIBUTION
CIRCUIT
CENTER LINE
CEILING
CONDUIT ONLY
CENTER
DIMENSION
EXISTING
ELECTRICAL
CONDUIT
ARCHITECT
FLOOR
GALVANIZED RIGIDGRS
STEEL
EM EMERGENCY
ALUM/AL ALUMINUM
FLUOR FLUORESCENT
GENERALGC
CONTRACTOR
CATV CABLE TV
CCTV CLOSED CIRCUIT TV
EC ELECTRICAL
CONTRACTOR
GFI
(EL) EVENING LIGHT
NUMBERNO.
(NL) NIGHT LIGHT
ABBREVIATIONS
D DIMMER
FC FOOT CANDLE
FLA FULL LOAD AMPS
MINIMUMMCA
CIRCUIT AMPS
MAXIMUM OVERMOCP
CURRENT PROTECTION
SHEET NOTE REFERENCE SYMBOL;
SEE ASSOCIATED NOTE ON SAME SHEET
SCHEDULE NOTE REFERENCE SYMBOL;
SEE ASSOCIATED NOTE ON SAME SHEET
FEEDER DESIGNATION;
SEE ASSOCIATED NOTE ON SAME DETAIL
DETAIL NOTE REFERENCE SYMBOL;
SEE ASSOCIATED NOTE ON SAME DETAIL
INDICATES QUANTITY OF
TELEPHONE OUTLETS
INDICATES QUANTITY OF
DATA OUTLETS
NOT TO SCALENTS
NOM NOMINAL
4
SAN JOSE
EVERGREEN VALLEY COLLEGE
COMMUNITY DISTRICT
ISSUANCE:PROJECT NO:16.029
DATE: 05/15/2017
DRAWN | CHECKED:CADD | NA
SHEET NO:
SCALE:
SHEET:
PROJECT:
100% CONSTRUCTION DOCUMENTATION -PACKAGE #2
CAMPUS WAYFINDING SIGNAGE
REVISION:
4 05/15/17 CCD-01
N
IDENTIFICATION STAMP
DIVISION OF THE STATE ARCHITECT
OFFICE OF REGULATION SERVICES
FILE NO.
APPL. NO.
AC FLS SS
DATE
________
________
43-C1
01-116103
Digital Message Sign
60 Garden Court Suite 210 Monterey, CA 93940
T.831.646.3330 F.831.646.3336 www.acemb.com
Project No.
ONTEREY
NGINEERS
ONSULTING
E
M
URUM A C
AY, INC.B
THE USE OF THE PLANS AND SPECIFICATIONS IS RESTRICTED TO THE
ORIGINAL SITE FOR WHICH THEY WERE PREPARED, AND PUBLICATION
THEREOF IS EXPRESSLY LIMITED TO SUCH USE. REUSE, REPRODUCTION OR
PUBLICATION BY ANY METHOD IN WHOLE OR IN PART IS PROHIBITED. TITLE
TO THE PLANS AND SPECIFICATIONS REMAINS WITH AURUM CONSULTING
ENGINEERS, INC., AND VISUAL CONTACT WITH THEM CONSTITUTES PRIMA
FACIE EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS.
16086.00
E2.0AOVERALL SITE PLAN
250' 125'0' 250'
1"=250'-0"
SHEET NOTES
1. PROVIDE & INSTALL 2"C., 4 #4 & 2 #8 GND. BETWEEN EXISTING FACILITIES
SHOP PANEL AND NEW DIGITAL SIGN.
2. IN-GRADE CONCRETE CHRISTY PULLBOX #N16 WITH LID LABELED "LIGHTING".
3. SEE E2.5 FOR CONTINUATION.
4. EXISTING CONDUIT FROM LIBRARY TELECOM ROOM (EXISTING IDF ROOM) TO
EXISTING PULLBOX. SEE GENERAL NOTES ON THIS SHEET FOR ADDITIONAL
REQUIREMENTS FOR THIS CONNECTION AT EXISTING LETC IDF LOCATION.
5. INTERCEPT EXISTING FIBER OPTIC CABLE CONDUIT IN THIS PULLBOX.
EXTEND NEW CONDUIT TO NEW DIGITAL SIGN WITH NEW FIBER OPTIC CABLE.
6. PROVIDE & INSTALL 2
1
2
"C. WITH NEW OM3 DUAL STRAND MULTI-MODE FIBER
OPTIC CABLE. EXTEND TO NEW DIGITAL SIGN.
7. PROVIDE & INSTALL CHRISTY #N30 PULLBOX, LID LABELED "TELECOM".
8. SEE SHEET E2.1 FOR CONTINUATION.
9. WHERE PULLBOX IS LOCATED SUCH THAT IS SUBJECT TO VEHICULAR
TRAFFIC; PROVIDE & INSTALL TRAFFIC RATED LID.
10. APPROXIMATE LOCATION OF EXISTING IDF CABINET; CONTRACTOR SHALL
FIELD VERIFY EXACT LOCATION. PROVIDE AND INSTALL NEW MULTI-MODE
FIBER OPTIC CABLE AT EXISTING IDF AND EXTEND TO NEW DIGITAL SIGN VIA
EXISTING 2"C. AND NEW CONDUIT AS SHOWN ON PLANS.
4
A. CONTRACTOR SHALL LOCATE ALL (E) UNDERGROUND UTILITIES
PRIOR TO TRENCHING AND TAKE CAUTION TO AVOID DAMAGE
DURING TRENCHING. HAND TRENCH IF NECESSARY.
CONTRACTOR SHALL MAKE ALL REPAIRS TO DAMAGED EXISTING
UTILITIES AT NO CHARGE TO OWNER.
B. NEW TRENCH SHALL BE ROUTED TO SOUTH SIDE OF EXISTING
PATHWAY. FIELD COORDINATE TRENCH LOCATION WITH DISTRICT
REPRESENTATIVE AND LANDSCAPE ARCHITECT PRIOR TO START
OF WORK.
C. CONTRACTOR TO PROVIDE & INSTALL MEDIA CONVERTERS AT
SIGN AND AT LETC IDF ROOM. COORDINATE WITH OWNER'S
REPRESENTATIVE FOR FINAL PLACEMENT OF DEVICES. CONNECT
VIA
1
2
"C. WITH 120V CIRCUIT FROM NEAREST PANEL.
D. CONTRACTOR TO PROVIDE ACCESSORIES SUCH AS PATCH
CORDS, PATCH CABLES, CONNECTORS AND
VERTICAL/HORIZONTAL WIRE MANAGEMENT AS NEEDED FOR
COMMUNICATION BETWEEN THE NEW DIGITAL SIGN AND EXISTING
CAMPUS NETWORK.
E. COORDINATE ALL WORK WITH THE OWNER'S REPRESENTATIVE
PRIOR TO CONSTRUCTION. BDFs, IDFs AND THE MDC ARE SECURE
SPACES. COORDINATE ACCESS TO THESE SPACES AS WELL AS
THE CAMPUS UTILITY TUNNEL WITH OWNER'S REPRESENTATIVE
PRIOR TO CONSTRUCTION.
F. THE BDF AND IDFs ARE ACTIVE NETWORK FACILITIES. THE BDFs
AND IDFs ARE CONGESTED. TAKE THE UTMOST CARE TO NOT
DISTURB OR INTERRUPT EXISTING FACILIITES. REPORT ANY
DISRUPTIONS IMMEDIATELY TO THE UNIVERSITY AND NOTE IN
THE CONTRACTOR'S DAILY LOG. SCHEDULE ACCESS TO THE
BUILDINGS WITH THE OWNER'S REPRESENTATIVE 10 WORKING
DAYS IN ADVANCE OF CABLE PLACEMENT, TERMINATION AND
TESTING.
G. NEW OUTSIDE PLANT FIBER OPTIC STRANDS SHALL BE OM3
MULTIMODE AS INDICATED.
1. OM3 MULTIMODE:
a. MUST HAVE ST CONNECTORS ON BOTH ENDS
b. DO NOT USE ANY COUPLERS
c. MUST BE STRAIGHT RAN FIBER FROM THE MINI-MC IN
THE BUILDING TO THE BCM IN THE SIGN
2. OM3 MULTIMODE PERFORMANCE:
d. 850nm 3.0 dB/Km
e. 1300nm 1.0 dB/Km
f. OFL BANDWIDTH 3500 Mhz*Km/500MHz*Km
g. EFFECTIVE MODAL BANDWIDTH 4700Mhz*Km/-MHz*Km
H. THE CABLE SHEATH ID LABEL SHALL CONTAIN:
a. STRAND COUNT
b. GLASS TYPE 'OM3-MM".
c. BEGINNING STRAND NUMBER
d. ENDING STRAND NUMBER
e. NEAR END DESIGNATOR
f. MID SPAN SPLICE LOCATION DESIGNATOR
g. FAR END DESIGNATOR
J. LABEL THE FRONT OF THE FIBER TERMINATION SHELF WITH THE
CABLE NUMBER AND THE SHELF NUMBER.
K. PROVIDE PRE-INSALLATION OTDR, TESTING AND REPORTING
SUBMITTALS FOR FIBER OPTIC CABLES ON REELS PER THE
SPECIFICATIONS.
L. PROVIDE POST INSTALLATION BI-DIRECTIONAL OTDR TESTING,
LOSS BUDGET CALCULATIONS AND REPORTING SUBMITTALS PER
THE SPECIFICATIONS.
M. PROVIDE POST INSTALLATION BI-DIRECTIONAL POWER
METER/LIGHT SOURCE ATTENUATION TESTING AND REPORTING
SUBMITTAL PER THE SPECIFICATIONS.
N. CABLE ROUTING SHOWN REPRESENTS THE MOST EFFICIENT
PATHWAY. CONTRACTOR IS RESPONSIBLE TO PROVIDE THE
INSTALLATION AND MAKE THE APPROPRIATE ADJUSTMENT IN THE
FIELD BASED ON THE CONDITIONS ENCOUNTED IN THE FIELD.
GENERAL NOTES:
B
B
B
B
B
E
J
E
J
HYD
DN
D
N
D
N
DN
HYD
B
H
Y D
H Y
D
W
V
W
V
W
V
H Y
D
B
B
B
B
B
E
J
E
J
HYD
DN
D
N
D
N
DN
HYD
B
H
Y D
H Y
D
W
V
W
V
W
V
H Y
D
GULLO II
A&R
STUDENT
SERVICES
CENTER
ACACIA
ROBLE
AUTOTECH
CEDRO
LIBRARY/
EDUCATIONAL
TECH CENTER
PHYSICAL
EDUCATION
GULLO
STUDENT
CENTER
VISITOR
CENTER/
CENTRAL
PLANT/
POLICE/
S3 BUILDING
FITNESS
VISUAL
ARTS
PERFORMING
ARTS
SEQUOIA
LECTURE
HALL
SEQUOIA
RACQUETBALL
REPRO-
GRAPHICS
EVERGREEN
LAKE
S
A
N
F
E
L
I P
E
R
O
A
D
S
A
N
F
E
L
I
P
E
R
O
A
D
P
A
S
O
D
E
A
R
B
O
L
E
S
P A S O D E A R B O L E S
P
A
S
O
D
E
A
R
B
O
L
E
S
CDC
CRIMINAL JUSTICE
TRAINING CENTER
DISTRICT
OFFICE
SHOPPING
CENTER
FUTURE DEVELOPMENT
SOCCER
MULTIUSE
ATHLETIC FEILD
SOFTBALL
FEILD
TENNIS
AMPHITHEATER
CHURH ON THE
ROCK
DISTRICT
WAREHOUSE
Y
E
R
B
A
B
U
E
N
A
R
O
A
D
LOT 2
STUDENT
PARKING
LOT 1
STUDENT
PARKING
LOT 3
STAFF
PARKING
LOT 4
STAFF/ STUDENT/
VISITOR PARKING
LOT 6
STAFF
PARKING
LOT 7
STUDENT
PARKING
LOT 7
STUDENT
PARKING
CRIMINAL
JUSTICE
TRAINING
CENTER
S3 BUILDING
S3 BUILDING
Y
E
R
B
A
B
U
E
N
A
R
O
A
D
Y
E
R
B
A
B
U
E
N
A
R
O
A
D
Y
E
R
B
A
B
U
E
N
A
R
O
A
D
Y E
R B
A
B U
E N
A
R O
A D
LOT 9
STUDENT
PARKING
LOT 9
STUDENT
PARKING
LOT 9
STUDENT
PARKING
CHURH ON THE
ROCK
LOT 6
STAFF
PARKING
LOT 7
STUDENT
PARKING
LOT 7
STUDENT
PARKING
SEQUOIA
LECTURE
HALL
STUDENT
SERVICES CENTER
LOT 3
STAFF
PARKING
P
A
S
O
D
E
A
R
B
O
L
E
S
PHYSICAL
EDUCATION
PERFORMING
ARTS
VISUAL
ARTS
EVERGREEN
LAKE
-
E2.1A
168
2
E3.0
1
6
16
7
1
E3.0
1
2
1
E3.0
5
6
1
2
1
E3.0
1 3
-
E2.5
4
6
2
1
E3.0
9TYP.
(E) IDF
10
SAN JOSE
EVERGREEN VALLEY COLLEGE
COMMUNITY DISTRICT
ISSUANCE:PROJECT NO:16.029
DATE: 05/15/2017
DRAWN | CHECKED:CADD | NA
SHEET NO:
SCALE:
SHEET:
PROJECT:
100% CONSTRUCTION DOCUMENTATION -PACKAGE #2
CAMPUS WAYFINDING SIGNAGE
REVISION:
4 05/15/17 CCD-01
N
IDENTIFICATION STAMP
DIVISION OF THE STATE ARCHITECT
OFFICE OF REGULATION SERVICES
FILE NO.
APPL. NO.
AC FLS SS
DATE
________
________
43-C1
01-116103
Digital Message Sign
60 Garden Court Suite 210 Monterey, CA 93940
T.831.646.3330 F.831.646.3336 www.acemb.com
Project No.
ONTEREY
NGINEERS
ONSULTING
E
M
URUM A C
AY, INC.B
THE USE OF THE PLANS AND SPECIFICATIONS IS RESTRICTED TO THE
ORIGINAL SITE FOR WHICH THEY WERE PREPARED, AND PUBLICATION
THEREOF IS EXPRESSLY LIMITED TO SUCH USE. REUSE, REPRODUCTION OR
PUBLICATION BY ANY METHOD IN WHOLE OR IN PART IS PROHIBITED. TITLE
TO THE PLANS AND SPECIFICATIONS REMAINS WITH AURUM CONSULTING
ENGINEERS, INC., AND VISUAL CONTACT WITH THEM CONSTITUTES PRIMA
FACIE EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS.
16086.00
E2.1APARTIAL SITE PLAN
40' 20'0' 40'
1"=40'-0"
4
GENERAL NOTES:
A. CONTRACTOR SHALL LOCATE ALL (E) UNDERGROUND
UTILITIES PRIOR TO TRENCHING AND TAKE CAUTION TO
AVOID DAMAGE DURING TRENCHING. HAND TRENCH IF
NECESSARY. CONTRACTOR SHALL MAKE ALL REPAIRS
TO DAMAGED EXISTING UTILITIES AT NO CHARGE TO
OWNER.
B. FOR ALL EXISTING ELECTRICAL DEVICES, EQUIPMENT
AND PULLBOXES, CONTRACTOR SHALL FIELD VERIFY
EXACT LOCATION.
C. NEW TRENCH SHALL BE ROUTED TO SOUTH SIDE OF
EXISTING PATHWAY. FIELD COORDINATE TRENCH
LOCATION WITH DISTRICT REPRESENTATIVE AND
LANDSCAPE ARCHITECT PRIOR TO START OF WORK.
D. CONTRACTOR TO PROVIDE & INSTALL MEDIA
CONVERTERS AT SIGN AND AT EXISTING IDF CABINET.
COORDINATE WITH OWNER'S REPRESENTATIVE FOR
FINAL PLACEMENT OF DEVICES. PROVIDE & INSTALL 12"
SQ. x 4" DEEP NEMA 3R PULLCAN AS NECESSARY FOR
DEVICE PROTECTION. EXTEND SIGNAGE 120V CIRCUIT
VIA
1
2
"C., 2 #10 & 1 #10 GND WHERE CONVERTER
REQUIRES POWER.
E. CONTRACTOR TO PROVIDE ACCESSORIES SUCH AS
PATCH CORDS, PATCH CABLES, CONNECTORS AND
VERTICAL/HORIZONTAL WIRE MANAGEMENT AS NEEDED
FOR COMMUNICATION BETWEEN THE NEW DIGITAL SIGN
AND EXISTING CAMPUS NETWORK.
F. THE BDF AND IDFs ARE ACTIVE NETWORK FACILITIES.
THE BDFs AND IDFs ARE CONGESTED. TAKE THE UTMOST
CARE TO NOT DISTURB OR INTERRUPT EXISTING
FACILIITES. REPORT ANY DISRUPTIONS IMMEDIATELY TO
THE UNIVERSITY AND NOTE IN THE CONTRACTOR'S
DAILY LOG. SCHEDULE ACCESS TO THE BUILDINGS WITH
THE OWNER'S REPRESENTATIVE 10 WORKING DAYS IN
ADVANCE OF CABLE PLACEMENT, TERMINATION AND
TESTING.
G. NEW OUTSIDE PLANT FIBER OPTIC STRANDS SHALL BE
OM3 MULTIMODE AS INDICATED.
1. OM3 MULTIMODE:
a. MUST HAVE ST CONNECTORS ON BOTH ENDS
b. DO NOT USE ANY COUPLERS
c. MUST BE STRAIGHT RAN FIBER FROM THE
MINI-MC IN THE BUILDING TO THE BCM IN THE
SIGN
2. OM3 MULTIMODE PERFORMANCE:
d. 850nm 3.0 dB/Km
e. 1300nm 1.0 dB/Km
f. OFL BANDWIDTH 3500 Mhz*Km/500MHz*Km
g. EFFECTIVE MODAL BANDWIDTH
4700Mhz*Km/-MHz*Km
H. THE CABLE SHEATH ID LABEL SHALL CONTAIN:
a. STRAND COUNT
b. GLASS TYPE 'OM3-MM".
c. BEGINNING STRAND NUMBER
d. ENDING STRAND NUMBER
e. NEAR END DESIGNATOR
f. MID SPAN SPLICE LOCATION DESIGNATOR
g. FAR END DESIGNATOR
J. LABEL THE FRONT OF THE FIBER TERMINATION SHELF
WITH THE CABLE NUMBER AND THE SHELF NUMBER.
K. PROVIDE PRE-INSALLATION OTDR, TESTING AND
REPORTING SUBMITTALS FOR FIBER OPTIC CABLES ON
REELS PER THE SPECIFICATIONS.
L. PROVIDE POST INSTALLATION BI-DIRECTIONAL OTDR
TESTING, LOSS BUDGET CALCULATIONS AND REPORTING
SUBMITTALS PER THE SPECIFICATIONS.
M. PROVIDE POST INSTALLATION BI-DIRECTIONAL POWER
METER/LIGHT SOURCE ATTENUATION TESTING AND
REPORTING SUBMITTAL PER THE SPECIFICATIONS.
N. CABLE ROUTING SHOWN REPRESENTS THE MOST
EFFICIENT PATHWAY. CONTRACTOR IS RESPONSIBLE TO
PROVIDE THE INSTALLATION AND MAKE THE
APPROPRIATE ADJUSTMENT IN THE FIELD BASED ON THE
CONDITIONS ENCOUNTED IN THE FIELD.
SHEET NOTES
1. EXISTING CHRISTY CONCRETE PULLBOX FOR POWER TO REMAIN.
2. EXISTING CHRISTY CONCRETE PULLBOX FOR COMMUNICATIONS TO REMAIN.
3. NOTE NOT USED.
4. NOTE NOT USED.
5. SEE E2.0 FOR CONTINUATION.
6. 2"C. WITH OM3 DUAL STRAND MULTI-MODE FIBER OPTIC CABLE TO NEW
DIGITAL SIGN.
7. 2"C., 4 #4 & 2 #8 GND TO NEW MONUMENT AND DIGITAL SIGN.
8. IN-GRADE CONCRETE CHRISTY #N30 PULLBOX, LID LABELED "TELECOM".
9. IN-GRADE CONCRETE CHRISTY PULLBOX #N16 WITH LID LABELED "LIGHTING".
10. 1
1
2
"C., 2 #4 & 1 #8 GND.
11. PER GENERAL DEMOLITION NOTES ON E0.2; CONTRACTOR SHALL
DISCONNECT AND REMOVE EXISTING LIGHTING CIRCUIT, ENSURE IT IS NO
LONGER ACTIVE AT OLD DISTRICT OFFICE PANEL.
12. CONTRACTOR SHALL COIL 20' OF CIRCUIT CONDUCTORS IN PULLBOX
CAPPED AND TAGGED FOR EXTENSION TO NEW DIGITAL SIGN/STEP-DOWN
TRANSFORMER.
13. CONTRACTOR SHALL COIL 20' OF FIBER OPTIC CABLE IN PULLBOX, CAPPED
AND TAGGED FOR EXTENSION TO NEW DIGITAL SIGN/MONUMENT SIGN.
14. INSTALL 2 #4 & 1 #8 GND IN EXISTING CONDUIT BETWEEN PULLBOXES.
15. CONNECT NEW CIRCUIT TO MONUMENT SIGN STEP-DOWN TRANSFORMER.
COIL 20' OF CIRCUIT CONDUCTORS AT PULLBOX TO ENSURE LENGTH
NECESSARY FOR CONNECTION.
16. PER GENERAL DEMOLITION NOTES ON E0.2; CONTRACTOR SHALL
DISCONNECT AND REMOVE EXISTING LOW VOLTAGE CABLE.
S
A
N
F
E
L
I
P
E
R
O
A
D
P
A
S
O
D
E
A
R
B
O
L
E
S
DISTRICT
OFFICE
2
1
15
14 11
6
6
10
8 13
9 12
7
10
9
8
7
6
567
16
SAN JOSE
EVERGREEN VALLEY COLLEGE
COMMUNITY DISTRICT
ISSUANCE:PROJECT NO:16.029
DATE: 05/15/2017
DRAWN | CHECKED:CADD | NA
SHEET NO:
SCALE:
SHEET:
PROJECT:
100% CONSTRUCTION DOCUMENTATION -PACKAGE #2
CAMPUS WAYFINDING SIGNAGE
REVISION:
4 05/15/17 CCD-01
N
IDENTIFICATION STAMP
DIVISION OF THE STATE ARCHITECT
OFFICE OF REGULATION SERVICES
FILE NO.
APPL. NO.
AC FLS SS
DATE
________
________
43-C1
01-116103
Digital Message Sign
60 Garden Court Suite 210 Monterey, CA 93940
T.831.646.3330 F.831.646.3336 www.acemb.com
Project No.
ONTEREY
NGINEERS
ONSULTING
E
M
URUM A C
AY, INC.B
THE USE OF THE PLANS AND SPECIFICATIONS IS RESTRICTED TO THE
ORIGINAL SITE FOR WHICH THEY WERE PREPARED, AND PUBLICATION
THEREOF IS EXPRESSLY LIMITED TO SUCH USE. REUSE, REPRODUCTION OR
PUBLICATION BY ANY METHOD IN WHOLE OR IN PART IS PROHIBITED. TITLE
TO THE PLANS AND SPECIFICATIONS REMAINS WITH AURUM CONSULTING
ENGINEERS, INC., AND VISUAL CONTACT WITH THEM CONSTITUTES PRIMA
FACIE EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS.
16086.00
E2.5
PARTIAL SITE PLAN -
FACILITIES SHOP BLDG.
SHEET NOTES
1. APPROXIMATE LOCATION OF EXISTING 120/208V, 3Ø ELECTRICAL PANEL.
FIELD VERIFY EXACT LOCATION. AT PANEL, CONTRACTOR SHALL PROVIDE
AND INSTALL (1) 25A/1P (FOR DIGITAL SIGN) & (1) 20A/1P (FOR MONUMENT
SIGN) CIRCUIT BREAKERS IN AVAILABLE SPACE. NEW CIRCUIT BREAKERS
SHALL MATCH EXISTING IN TYPE AND AIC RATING.
2. 12" x 16" x 6" DEEP PULLCAN WITH SCREW COVER NEMA 3R, HOFFMAN OR
EQUAL. FIELD VERIFY EXACT MOUNTING HEIGHT AT BUILDING EXTERIOR.
3. CONTRACTOR SHALL PROVIDE AND INSTALL 2KVA, 120V:480V, WALL
MOUNTED TRANSFORMER, NEMA 1, "2S1F" SQUARE D OR EQUAL. FIELD
VERIFY EXACT LOCATION WITH ARCHITECT PRIOR TO INSTALLATION FOR
MONUMENT SIGN LIGHT.
4. CONTRACTOR SHALL PROVIDE AND INSTALL 3 KVA,120V:480V, WALL
MOUNTED TRANSFORMER, NEMA 1, "3S1F" SQUARE D OR EQUAL. FIELD
VERIFY EXACT LOCATION WITH ARCHITECT PRIOR TO INSTALLATION FOR
DIGITAL DISPLAY SIGN.
5. 1
1
2
"C., 2 #4 & 1 #8 GND.
6. CONTRACTOR SHALL UPDATE PANELBOARD SCHEDULE WITH NEW TYPED
SCHEDULE FOR NEW ADDED LOADS.
7. 2"C., 4 #4 & 2 #8 GND.
8. IN-GRADE CONCRETE CHRISTY PULLBOX #N16 WITH LID LABELED "LIGHTING".
9. SEE E2.0 FOR CONTINUATION.
10.
3
4
"C., 2 #10 & 1 #10 GND.
10' 5'0' 10'
GENERAL NOTE:
A. CONTRACTOR SHALL LOCATE ALL (E) UNDERGROUND
UTILITIES PRIOR TO TRENCHING AND TAKE CAUTION TO
AVOID DAMAGE DURING TRENCHING. HAND TRENCH IF
NECESSARY. CONTRACTOR SHALL MAKE ALL REPAIRS TO
DAMAGED EXISTING UTILITIES AT NO CHARGE TO OWNER.
B. CONTRACTOR TO PROVIDE & INSTALL MEDIA
CONVERTERS AT SIGN AND AT LETC IDF ROOM.
COORDINATE WITH OWNER'S REPRESENTATIVE FOR
FINAL PLACEMENT OF DEVICES.
C. CONTRACTOR TO PROVIDE ACCESSORIES SUCH AS
PATCH CORDS, PATCH CABLES, CONNECTORS AND
VERTICAL/HORIZONTAL WIRE MANAGEMENT AS NEEDED
FOR COMMUNICATION BETWEEN THE NEW DIGITAL SIGN
AND EXISTING CAMPUS NETWORK.
1"=10'-0"
4
J
(E) PANEL "C1"
4
3
5
16
WP
8
7 9
2
E3.0
1
E3.0
2 7
10