Transcript
Page 1: Zksoftware Userguide

1

F4 Pulse Web sever User Guide

PREFACE

All part of the manual are the property of ZKsoftware Inc, no par of the

manual may be transmitted in any form by any means without the prior written

permission of Zksoftware Inc. All functions take the actual product as product standard, as a result of the product unceasing renewal, ZKsoftare Inc does not assure that the actual product is consistent with this document, and is not liable for any damages and trouble whatsoever arising out of the inconsistence, in formation in the document is subject to change without notice. Other trade mark and trade name may be used in the document to refer to either the entities claiming the marks and names or their products publisher disclaim any proprietary interest in the trade name other than its own

F4-PLUS feature

F4 Plus hardware adopts the international popular POE design that allows for easy, guards against the static and electricity jam, F4plus provides:

·Over current and voltage protest in output and input.

·Prevent dismantle alarm.

·Monitors the voltage and watchdog system. The quality is excellence.

The Web Server remote data collecting/ access control system, is based on the TCP/IP

standard network architecture infrastructure, adopt the common WEB page request to

handle and the manage data , It is not limited by area, and isn’t need to install other software,

can download and manage the data information in the finger access control device through IE,

Page 2: Zksoftware Userguide

2

NETSCAPE Brewers , then make all kind of the statistics report for enterprise management

and decision _making, improve effective of management.

1 Configure the Web Server Running Environment

First use the Web server to detect the IP address of fingerprint device, E.g.

the IP address of the fingerprint device is 192.168.1.115. Input

thehttp://192.168.1.115 to the IE address column, enter and like as the following

figure.

The default name of super administer is the admin, the login password is

admin888.

Notice:In order to improve system security, please enter “Configure Web

Server parameter” to revise the password

1.1 Identity authentications

After Click to configure Web Sever parameter, put up the identity

authentication to check whether owns the privilege to configure the Web Sever

parameter. Input the user name and password to examine, after meet the

Page 3: Zksoftware Userguide

3

authentication request, and then enter to configure the Web Server

1.2 Web Server Running Environment

Enter to configure interface, like as following figure.

Web Root Path: Source file directory and its default value is myweb.

Web Port: the default port is 80。

Session:How many users are available to login at same time?

Session Timeout:The time define as the overtime of linking, when the user has

not done any operation in a setting period, the system will

default the user has been away, and the exit automatically.

Default Language: The default language is Chinese and English.

Above each parameter all are able to changed, first make that the cursor is located in

the text frame, and directly input the revises value. For example, changes Web Port to 8888,

input http://192.168.1.115: 8888 in the address column of IE browser when enter the system.

As the Default Language is a Chinese, the system prompt language all is a Chinese; As the

Default Language is English, the system prompt language all is English.

Note: according to the real condition to revise the Default Language and the Web Port,

Page 4: Zksoftware Userguide

4

the best way is to use the default setup. After complete the setup to save it, be sure restart

the device immediately or later, so the configuration changes take effect

1.3 Configure Administer

Click next to enter the administer interface, the system has 3 kinds of user

Supper admin: Own the privilege to use all function of the device. Such as

Access control setup. User management. System setup.

Data manage.

Manager: It is only used to access control setup and user administer.

Individual User:It is only used to admin the user.

Super Administer password revision: Inputs the admin in the user management, login the

password to input the new password. Clicks "Save Setup" to modify the password.

Inputs the user name in the user management, login the password and select the respective

group, after click ‘ Save Setup’, it will add a manager to system, and also can increase a record in

the list. After the operation complete, clicks next step to enter Web Server Setup to the complete

interface, if you have configured the Web Server parameter, please restart the terminal to make

that the setup become effective; If needs to reconfigure Web Server setup single-click '

Reconfigure '; If needs to login the Web system, please click ‘Login Web System’

Page 5: Zksoftware Userguide

5

Note: it is only the supper administer own the option to configure Web Sever, whatever it is in

the any condition the super admin can not be canceled, can but modify the password, the new

registered administer can not modify the password or the privilege, if do not need, please

delete it.

2 Access Control Setup

The Access Control Setup is the configuration of user’s unlocks Time Periods and

unlock combine.

The access control setup module include: Time Periods setup, group setup,

unlock combine setup.

Each user’s setup made by the group setup, the use group Time Periods, the user

Time Periods belong to ones, The grouping is that the user is distributed into a group, like as 1

group, 2 group and so on; it is capable to distribute user in the adding new user or modifying user

information procedure . The group Time Periods can support to choose most three time, these

three Time Periods are "or" the relations (it is enough namely to satisfy only one of the three).

Unlocking combination definition is the combination which is defined by different unlocking;

each combination is composed by the different group.

Take a simple to explain the unlocking condition a registration user can:

1: The user’s group must be in the unlocking combination (also to be possible together with other

groups in an unlocking combination, but needs to be able to together unlock door).

2:the current unlocking time locate in any effective time range of the user Time Periods or group

period time, The system default the new user registered belong to the first group, and the

grouping is the first group, and the group Time Periods is "1", until configure access control

setup the new user registered is defaulted in the unlocking status (if user modify the

corresponded setup of the access control , system will change along with user's revision), if

there are no user to belong to the group in the unlock combine, then user can not unlock door

Page 6: Zksoftware Userguide

6

Verification Flow of Access Control:

2.1 Definition Time Periods

The default interface is a definition of the time periods of access control setup; it is available

directly to set Time Periods through the interface.

The time period is the minimum hour unit of access control option. The overall system is

ability to divide into maximum 50 Time Periods. Each time period is defined as seven times

ranges a week, each time range is an effective time periods in the 24 hours of a day. Each user is

ability to set 3 time periods, the relationships among three time periods are "or", it is effective so

long as the verified time can satisfy one of these three time period,. Each time period range format

is: HH:MM-HH:MM, the system defers to 24 hours mode and get accurate minimum unit until the

minute.

The end- time is less than the start- time (23:57- 23:56) to express the entire day to be

Yes

No

Yes

No

Yes

No

No

Yes

Yes

No

Effective TZ

Satisfy certain unlocking combination

Combine to unlock door

Next GRP user

Can’t unlock Door

Voice prompts “Thank You” to confirm success

User GRP in unlocking Comb

TimeZone Deny

GRP TZ User TZ

User presses fingerprint

Can’t unlock door Open

Page 7: Zksoftware Userguide

7

forbidden, the end-time is larger than the start- time (00:00- 23:59) to express this range is

effective.

The effective time period for the user to unlock: Entire day open (00: 00-23: 59) or the end-

time is larger than the start- time in the time period.

Input time period serial number: After set the time period, clicks the save setup, and then

added the time period appear under the interface table. Serial number is 1 --50

2.2 Groups Setting

The group setup is ability to divide the user into a group; the system has defined 5 groups: 1

group, 2 groups, 3 groups, 4 groups, 5 groups. The system default the new user registered

belongs to 1 group, ability to redistributes user into each group while add new user or revise

user procedure.

The group Time Periods has three Time Period, their relationship are "or". Input group

serial number: After Set group setup, clicks the Save to save setup , then add the group

setup express the under table. Serial number 1 -5

Page 8: Zksoftware Userguide

8

Note: this group is invalid when the Time Period 1 is 0, if the time Period 2 is 0, otherwise

the time Period 3 is invalid

2.3 Access Combine

the unlocks combination is the direct performance to control locks, for example, if a user

want that all user registered are not able to unlock, user would set the 10 unlocks

combination all are empty.

The unlock combination definition is to define different ability the unlocking

combination; each combination is composed by the different group. The unlocking

combination directly use group number, does not consider the user verification sequence

between each group. For example "1,2,3"expressed 1 group , 2 group , 3 group , at least

one user of the each group together are verified until the lock can be operated; "4" an express

that a alone user of 4 group has been verified then the lock is able to be unlocked

Note:Unlocking combine of the system initial default is “1” (Default new user

registered t can unlock)

Page 9: Zksoftware Userguide

9

After set unlocking combine, click Save to save setup, the system can simultaneously define

maximum 10 kinds the to unlock combination, so long as one of them can pass then

3 User Management

Click icon to enter user management interface, this interface is defaulted

as “Manage all User” interface.

User management module include: manage all user, add new user, query in and

out log

3.1 Management All User

User is ability to examine all information of personnel registered through this

interface. And can utilize the work code, the name and the group to achieve the

condition inquiry,

Directly clicks the work code or the name. And enter the page to change personnel

information

Page 10: Zksoftware Userguide

10

This interface and the new user registered interface are same. Please pay attention that the

special note place is difference.

3.2 Add New User

Click “Add New User” in the “Setting Information” column, following interface appear.

Input the new user information according to the page prompt, attention must be paid to the

work code do not have conflict, choose the group which has been defined in the access control

setup to the respective group (the default group is 1), choose to use or not to use the group Time

Period, if does not use the group Time Period, other choose 3 Time Period, the relations are "or",

these 3 Time Period is ability effectively to be visited, user choose the privilege, and click Save

Page 11: Zksoftware Userguide

11

to backup the setup after complete to fulfill the information, if the system prompt that user

information has correctly stored up, that indicate added successfully, otherwise repeat the

operation process according to the prompt. Through the external fingerprint sensor we can

achieve "Enrollment fingerprint" operation. But it is needs to be installed. (Installs the ZKOnlin

module .please see appendix 1)

After the fingerprint sensor is connected with PC, may click the enrollment fingerprint in the

adding new user interface, and chooses any finger to enroll, like as the following figure shows:

Press the identical finger four times, the successful enrollment will show following figure.

Page 12: Zksoftware Userguide

12

Click the "confirms" key to confirm. If the fingerprint quality is not good or does not

simultaneously press the identical finger, then show fail to enroll the fingerprint

After completes the Enrollment, to verify whether the fingerprint is effective or not, click the

verification fingerprint that shows as follow.

Ask you place a finger, if the prompt information is: "The fingerprint verification fail" that

explain you place the finger is wrong or the pressing way is not right. Please repress the finger

again. The display information prompts that "the fingerprint verification is successful", and

automatic shut-off this window. Validate finish.

3.3 Query the event log

Click “Query the event log” in the “Setup information” following interface appear

Page 13: Zksoftware Userguide

13

Input a work code to inquire the event logs for someone or all people within the input time

period range. Click next step to examine these logs, and might choose the logs to download and

save it to the computer

4. System Setting

Click icon of system setup; enter the default interface that is the “communication parameter” interface.

The system setting module includes six parts: Communication Parameter.

Access Control Parameter, Fingerprint

Parameter, Synch Time. Manage Power. Other

Parameter.

4.1Communcation Parameter

View the communication setup of the fingerprint terminal through this

communication interface.

Page 14: Zksoftware Userguide

14

Here you can modify the communication parameters, click the Save button to

save setup after to complete modified it, if the IP address has been modified,

please close the window and be sure to restart the terminal, and refresh the setup,

synch the configuration and the fingerprint terminal.

4.2 Access Control Parameter

Click the access control parameter in the setup column, show as follow

According to the demand to set the parameter:

Lock (Time duration of lock drive): fingerprint machine controls the time to open electronic lock, the minimum unit is 20ms; the system default value is 100ms.

Door Sensor Delay: the door has opened for a period of time until the machine trigger a

Page 15: Zksoftware Userguide

15

Warner; the period of time is door sensor delay.

Door Sensor Switch: there are three option that is none( NONE), normal open (NO), normal

close(NC) .the none means the door Sensor doesn’t apply, Normal Open is defined that The door

can be set to a Passage Mode in the normal ready work state, Normal Close means that the door is

close in the normal ready work state.

Duress Alarm Option: Use a new fingerprint to be special enrolled or defines a fingerprint

enrolled as the duress fingerprint, this fingerprint has been authenticating through fair and foul. the

system will Trigger a alam singal to prevent sameone is forced to open door.

Alarm delay:Defining automaction alarm time: when the duress alarm happen and the

system do not dirctly trigger alarm singal immediately, but can define a period time until

automactionly trigger alarm singal( 0-255sec.) the default time is 10Sec. the mode of validation alarm

The fingerprint machine fully supports three verification modes: 1:1 match, 1: N match, Password authentication, and here you can choose one or other

several verification ways for the duress alarm.

click the Save button to save setup after to complete modified it, and refresh the

setup,synch the configuration and the fingerprint terminal.

4.3 Fingerprint Parameter

Click “Access Control Parameter” in the setup information column, show as

follow.

Page 16: Zksoftware Userguide

16

Fingerprint Match Way:Select the 1:1 or 1: N way to match Show Score: whether show the quality value of fingerprint in the screen or not;

1: N Threshold: For helping in selecting threshold level settings, when there are many

fingerprint to match, it is better to set the threshold as “high”, avoid the system fail accept

fingerprint

1:1 Threshold: when use ID+ fingerprint to verify so set the Threshold level, due to the 1:1

matching is a high precision way, the threshold can set as “middle” or

“Low”, the system default level “highest”

click the Save button to save setup after to complete modified it, and refresh the

setup,synch the configuration and the fingerprint terminal.

4.4Synchroniztion Time

Click “Synch Time” in the setup information column, show as follow

Current terminal time: this time is to show the terminal time.

The system default correct way is: Synch the terminal and PC, Manually correct the

time.

Date: Show the date set on the terminal; the default format is YYYY-MM-DD.

If manually correct the time was selected, then ability to renew the date.

If want to modify the date format, then you can modify it in the other setup item

Click the Save button to save setup after to complete modified it, synch the

configuration and the fingerprint terminal

Page 17: Zksoftware Userguide

17

4.5 Power Management

Click “Power Management” in the setup information column, show as following

Power Management:Select the Power Management Mode, there are two modes to

select, the default value is open.

Time turn off:The system default value is 12:00, it can be modified it.

Idles Setting :The system default as shut down mode, it can be change to sleep state

Idles Time:The system default value is 30 minute, the device will go to sleep or shut

down until it within idles time 30 minute.

Time sleep: the system default is 12:05, after arrive at the defined time then the device

will go to sleep.

click the Save button to save setup after to complete modified it, and refresh the

setup,synch the configuration and the fingerprint terminal.

4.6 Other Parameter

Click “Other Parameter” in the setup information column, show as following

Page 18: Zksoftware Userguide

18

Only verify the number card: there are 2 kinds of choice, the default is yes

Must input the ID number: whether it has to input the ID number or not, while user

perform verification matching

Date format: The system default the machine date format is YY-MM-DD. Ability to

choose other format.

Voice prompt: while operate the terminal, whether needs the voice prompt or not.

Alarm Management log, when the surplus management log capacity achieved the set value,

the equipment will automatically send out warning information about the log is already full;

Alarm Attendance Log: when the remainder log capacity reached set numerical value, it will automatically sound a warning that logs were full.

Recheck Minute: In the set time scope (unit: Minute), if some person's had already been

checked his attendance log exist, then, second checking attendance but the result could not

preserve.

5 Data Management Click the data management icon; enter the “system information” interface that is a default

interface

the data management module is divided into 6 parts:The system information, the management

control, the downloading data, the uploading data, the operation log, remotely opens the door.

5.1 System information

This interface display information is the system information of the fingerprint machine that is

Page 19: Zksoftware Userguide

19

connected with PC, Examines the information of the fingerprint machine through software.

5.2 management control

Open “management control" in the setup information, show interface as follow

This interface utilizes Web Server to control shutting down, sleeping, restarting. And ability

to operate a data to the fingerprint machine.

Clear the manager privilege: Eliminates manager on the fingerprint machine.

Delete management log: Delete the management log on the fingerprint machine.

Delete all data: Delete all data on the fingerprint machine that include attendance data,

management data, and user data.

Page 20: Zksoftware Userguide

20

Delete user data: Delete user's fingerprint information.

5.3 download Data

Open " downloading data” in the setup information, show interface as follow:

Chooses a data which must be downloaded in the system data frame, ability to export 4 kinds

of data, after selecting, single-click downloading the define data, the form of data to be exported is

a dat format

5.4 Upload Data

Open “uploading Data” in the setup information column, show like as follow

Page 21: Zksoftware Userguide

21

Select uploading Data, then click next step. Like as follow

Click the brows to choose the file to be uploaded, click uploading data to achieve

operation.

5.5 Operation Log

Click operation log to view the event log of the fingerprint machine.

5.6 Remotely Open Door

Click remotely open door, and send a signal to the terminal to control the terminal open the

door, the system prompt the whether the is opened or not, after the operation finish.

Page 22: Zksoftware Userguide

22

6 About Us Software version No.:1.5.5

Renew time for edition :2005.12.20

Copyright: ZK software In

http://www.zksoftware.com

7 Logout Click logout to exit, return back the login interface.

Note:Use logout to exit the system, be ensuring to security of accounts and

password.

Page 23: Zksoftware Userguide

23

Appendix1

Install ZKOnline Module

1、 Install driver

It is need to install the driver of fingerprint sensor in the computer that is in use,

if the drive within Biokey SDK CD has been already installed, be allowed to skip this

step, before installing, please check your operating system (the front-end browser

operating system is windows; The background server operating system is Unix and

Linux) and the computer configuration meet the requirement of software running.

Before installing, if your computer has connected with the fingerprint sensor, be

best to take it off.

Put the CD into the CD-ROM drive of the computer, the installing software

automatically read or. Follow the prompts to execute Setup.exe

Note: The installing procedure only is the fingerprint sensor driver and the soft dog’s

driver.

The license:

1) The soft- dog license, please ensure the soft- dog correctly connect with the com port of

computer.

2) Uses the file license, needs to copy the permit file to directory under the Windows system.

2. Register the ZKOnline plug-in for client-end

It is need to register the ZKOnline plug-in in the client- end, and then can take effect in the

homepage and program development

1) copy following file to Windows system directory (c: \windows\system)

Zkonline.ocx controls storehouse file

Zkonline.lic license of the control storehouse file:

2) register controls zkonline.ocx:

Input following the computer orders in the “start" ---"run"

c:\windows\system\regsvr32.exe c:\windows\system\zkonline.ocx

Note:the directory of Windows98、ME system is c:\windows\system

the directory of Windows NT、2000、XP is c:\windows\system32

Page 24: Zksoftware Userguide

24

If there are no the background server, after installing above controls, then use the fingerprint

sensor to register the fingerprint.

To register installing background server COM+ module (option), please see appendix 2

Appendix 2:

To register installing background server COM+ module

if use the IIS+ASP to develop, then need to install and register COM+ module FPCom in the

background WEB server dll, step as follow

1. Enter the control panel - the administrative tool -the components service, show as follow:

Right -Clicks the mouse, select menu, newly built - application

2 found the new COM+ application, show as follow:

Page 25: Zksoftware Userguide

25

3、 clicks next step, create a empty application.

4、 inputs the name of the new application (here to input ' Sample '), continuously click the next

step until arrives at end, by now the COM+ application could add an item, show as follow:

Page 26: Zksoftware Userguide

26

5、 right -click the mouse , the select menu. Newly built - module, the following figure shows

Select the new module installing, choose FPCom.dll, and then complete the installment


Top Related