Transcript
Page 1: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Upstream QAM Certification

– DOCSIS 3.0 Presenter: Tony Holmes

CCTA 2014 Technical Training

San Juan, PR

In cooperation with

Page 2: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

HFC Network Architecture

Return Path Challenges

DOCSIS 3.0 Overview

Testing the Return Path

Using an Upstream Generator with FEC

Measuring/Analyzing Upstream Parameters

Live Demonstration of Return Path Impairments

Seminar Overview

Presentation Name Here Confidential & Proprietary Information of VeEX Inc. 2

Page 3: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Broadband Arcitectures

Return Path QAM Analysis Quick Guide Confidential & Proprietary Information of VeEX Inc. 3

Page 4: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Return Path: Cable Modem Signal

Cable Modems in each home are sending data back to the CMTS which is located in the Headend

Cable Modems on the same coaxial cable are “time sharing” the bandwidth:

5 MHz to 42 MHz (Annex B)

5 MHz to 65 MHz (Annex A)

Confidential & Proprietary Information of VeEX Inc. 4

Return Path

HFC Network Structure

Node

Headend

Optical Link Optical AMP Amplifier

Tap #1

Tap #2

Home #1 Home #2

Home #3 Home #4

Return Path

Page 5: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

TP 1: CMTS receiving signal quality

TP 2: RF level before electrical to optical conversion

TP 3: RF amplifier power output and tilt balancing with TP 4

TP 4: RF amplifier input signal level

TP 5: Tap #1 signal from Home #1 cable modem

TP 6: Tap #2 signal from Home #3 cable modem

TP 7: Signal loss between TP 6 and TP7

Confidential & Proprietary Information of VeEX Inc. 5

Return Path Test Points

Node

Headend

Optical Link Optical AMP Amplifier

Tap #1

Tap #2

1 2 3 4

5

6

7

Home #1 Home #2

Home #3

Home #4

Page 6: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Confidential & Proprietary Information of VeEX Inc. 6

Increase Upstream Bandwidth; What are the Problems?

HFC Return Path

Operators increase Return Path bandwidth by using higher QAM64, 128, 256.

Higher QAM introduces:

More noise sources affecting QAM64, 128 and 256

Must verify transmission quality with Return Path QAM analysis

5 42 65 80 100MHz

-25

dBmV

-40

Page 7: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Return Path Challenges

Confidential & Proprietary Information of VeEX Inc. 7 Return Path QAM Analysis Quick Guide

Page 8: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Real Time Signals Voice over IP (CATV)

Off air broadcasting (Telcos)

Perception of Industries Telephone Companies

Cable Operators

Technology and Tools MPEG-4 (Telcos)

Automated ingress monitoring system (CATV)

The Challenges

Confidential & Proprietary Information of VeEX Inc. 8

Page 9: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

The Weakest Link

Presentation Name Here Confidential & Proprietary Information of VeEX Inc. 9

Page 10: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Ingress Funneling Effect

Presentation Name Here Confidential & Proprietary Information of VeEX Inc. 10

Bi-directional system return path funnelling effect

Page 11: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Impairments

Presentation Name Here Confidential & Proprietary Information of VeEX Inc. 11

Radio Communications and Transient Noise

Page 12: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

DOCSIS 3.0

Confidential & Proprietary Information of VeEX Inc. 12 Presentation Name Here

Page 13: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

DOCSIS system

Enables transparent bi-directional of Internet Protocol (IP) traffic, between the cable system headend and

customer location

DOCSIS specification

Defines PHY & MAC layer protocols for communication & Ethernet frame transport between CMTS & CM

DOCSIS network comprises:

Cable Modem Termination System (CMTS) located at the headend

Cable Network - an all-coaxial or hybrid-fiber/coax (HFC) cable network

Cable Modem (CM) located at the Customer Premise

An Overview

DOCSIS

DOCSIS® Confidential & Proprietary Information of VeEX Inc 13

Transparent IP traffic

Wide Area

Network Cable Network

(HFC)

CMTS Cable Modem CPE

CM/CPE

Interface

CMTS/WAN

Interface

Page 14: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Milestones

DOCSIS

DOCSIS 1.0 (1999)

• 1st products certified (CableLabs started project in 1996)

• Open standard for high-speed data over cable

• Modest security, Best-effort service

DOCSIS 1.1 (2000)

• Quality-of-Service (QoS) service flows

• Baseline Privacy Interface (BPI+) Certificates

• Improved privacy & encryption process

DOCSIS 2.0 (2002)

• Improved throughput & robustness on Upstream

• 64/128 QAM modulation & higher symbol rates with FEC

• Programmable interleaving to upstream channels

DOCSIS 3.0 (2006)

• Channel bonding (4U/4D) for increased capacity

• IPv6 support

• Improved security (AES)

DOCSIS® 14 Confidential & Proprietary Information of VeEX Inc

Page 15: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Support new high bandwidth services of 50 to 100Mbps

Migrate existing customers to higher tier services

Better and more robust data encryption

Provide more IP address space using IPv6

Limit and reduce node splits

Reduce overall cost of CMTS ports

Independent scalability of upstream & downstream

Business Drivers

DOCSIS 3.0

DOCSIS® Confidential & Proprietary Information of VeEX Inc 15

Page 16: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Higher Bandwidth Applications

DOCSIS 3.0

Digital

Photos

Gaming

MP3

WMV

DVD

Blu-ray

SDTV

HDTV Mobile

Video

iPod

Walkman

You Tube

VOD

DVR/PVR

Data &

VoIP

Home

Networks

Web 2.0

DOCSIS® 16 Confidential & Proprietary Information of VeEX Inc

Page 17: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Consumers greed for speed

DOCSIS 3.0

17 DOCSIS® Confidential & Proprietary Information of VeEX Inc

Page 18: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

High bandwidth residential data and content

Video and photo uploads

Proliferation of social networking sites and applications

IP Video over DOCSIS (VDOC)

High definition Video to multiple devices

PCs, hybrid STBs, portable devices

High bandwidth Internet streaming

High Bandwidth Video conferencing

Cisco TelePresence

Commercial service

High bandwidth symmetrical data services

Bonded E1/T1 circuit emulation

High bandwidth Ethernet / L2VPN services

Services driving Channel Bonding

DOCSIS 3.0

DOCSIS® Confidential & Proprietary Information of VeEX Inc 18

Page 19: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Major Feature Overview

DOCSIS 3.0

• Bonded Downstream Channels

• 56Mbps (RAW) each, 448Mbps Total Increased DS bandwidth

• Bonded Upstream Channels

• 27Mbps (RAW) each, 122Mbps Total Increased US bandwidth

• IPV6 allows for 3.4x1038 IP addresses

• IP addresses are lengthened from 32 bits to 128 bits IPv6

• Existing DOCSIS 1.0, 1.1 and 2.0 systems

• Scalable deployment with easy subscriber migration Backwards compatibility

• IPTV-type applications

• Efficient “switched-video-like” bandwidth usage IP Multicast

• E1 & T1 circuit emulation Commercial

• Early Authentication and Encryption (EAE) and AES 128bit encryption which is more robust and secure

Network Security

DOCSIS® 19 Confidential & Proprietary Information of VeEX Inc

Page 20: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Channel bonding basically means data is transmitted to/from Cable Modems

using multiple individual RF channels instead of a single channel

DS Channel Bonding

DOCSIS 3.0

DOCSIS® Confidential & Proprietary Information of VeEX Inc 20

Using DOCSIS 3.0, data is transmitted to cable modems using multiple channels

Page 21: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Upstream Bonding

DOCSIS 3.0

Return Path QAM Analysis Quick Guide Confidential & Proprietary Information of VeEX Inc. 21

Using DOCSIS 3.0, upstream data is transmitted using multiple channels

Page 22: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Throughput Compared

DOCSIS 3.0

DOCSIS® Confidential & Proprietary Information of VeEX Inc 22

DOCSIS Version Date Rates – Annex A

Downstream Upstream

1.1 ~ 55.62 (50) Mbps 10.29 (9) Mbps

2.0 ~ 55.62 (50) Mbps 30.72 (27) Mbps

3.0 (4 Channels) ~ 222.48 (200+) Mbps 122.88 (108+) Mbps

3.0 (8 Channels) ~ 444.96 (400+) Mbps 122.88 (108+) Mbps

Page 23: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

DOCSIS 3.0 review

Physically the same as DOCSIS 2.0 signals

Consists of multiple QAM signals bonded logically together

Bonded channels can be contiguous or non-contiguous:

Contiguous - consists of frequency consecutive signals

Non-contiguous – interspersed with other carriers

MPEG-2 transport for downstream signals

QAM transport for upstream signals

IPv4 or IPv6 support

Enhanced security using EAE, etc.

Quick Summary

DOCSIS 3.0

DOCSIS® 23 Confidential & Proprietary Information of VeEX Inc

Page 24: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Testing the Return Path

Upstream Certification

Confidential & Proprietary Information of VeEX Inc. 24 Presentation Name Here

Page 25: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

SLM with DOCSIS 3.0 Cable Modem

Upstream Generator with FEC

QAM Analyzer

Spectrum Analyzer

Return Path Sweep

Leakage Detection

Tools of the Trade Return Path Testing

Confidential & Proprietary Information of VeEX Inc. 25

Page 26: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Check the DS and US power levels

‘Results’ should be displayed

Activate the Cable Modem

Confidential & Proprietary Information of VeEX Inc. 26

Page 27: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Access to All Downstream Carriers and Upstream

Confidential & Proprietary Information of VeEX Inc. 27

Page 28: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

USG Setup menu: 1. Enter the USG test parameters, then tap ‘Start’

2. Select Remote for shortcuts to allow quick access of Spectrum and Return Path Analysis

Modes

CX380 Remote View Option Confidential & Proprietary Information of VeEX Inc. 28

Using an USG with FEC

Page 29: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

At 60 MHz

Upstream Certification

Marginal Ingress

Return Path QAM Analysis Quick Guide Confidential & Proprietary Information of VeEX Inc. 29

Presence of Ingress

Page 30: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

At 39 MHz

Upstream Certification

Return Path QAM Analysis Quick Guide Confidential & Proprietary Information of VeEX Inc. 30

Marginal Ingress

Presence of Ingress

Page 31: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

At 15 MHz

Upstream Certification

Return Path QAM Analysis Quick Guide Confidential & Proprietary Information of VeEX Inc. 31

Marginal Ingress

Presence of Ingress

Page 32: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Histogram Analysis

Return Path QAM Analysis Quick Guide Confidential & Proprietary Information of VeEX Inc. 32

No Errors

With Pre and Post

Errors

Page 33: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Linear Distortions & QAM Ingress

QAM Impairments

Linear Distortions

QAM Ingress

Shows noise under the QAM carrier

Return Path QAM Analysis Quick Guide Confidential & Proprietary Information of VeEX Inc. 33

Page 34: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Noise in the Return Band

Spectrum Analyzer

Return Path QAM Analysis Quick Guide Confidential & Proprietary Information of VeEX Inc. 34

Page 35: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Presentation Name Here Confidential & Proprietary Information of VeEX Inc. 35

MER/BER Demonstration

Impairment simulation

Page 36: Upstream QAM Certification – DOCSIS 3.0 Presenter: Tony … QAM... · Upstream QAM Certification – DOCSIS 3.0 ... DOCSIS specification ... Independent scalability of upstream

Thank You Questions?

Confidential & Proprietary Information of VeEX Inc. 36

Tony Holmes

Tel: (510) 651-0500

[email protected]

www.veexinc.com

For more info on VeEX products

Please contact our Caribbean

Value Added Reseller (VAR)

[email protected]


Top Related