Transcript
Page 1: Agilent CDMA Base Station Over-Air Maintenance Toolliterature.cdn.keysight.com/litweb/pdf/5968-8696E.pdfAgilent CDMA Base Station Over-Air Maintenance Tool ... optimization platform

Configuration Guide

Agilent CDMA Base Station Over-Air Maintenance Tool

The Agilent Technologies CDMA Over-

Air Maintenance Tool is used to make

diagnostic measurements of cdmaOne,

IS-2000 (cdma2000 1x), and J-STD-008

CDMA base stations over the air. The

system software runs on a PC that

interfaces with a digital RF receiver or

a CDMA mobile phone or both.

Page 2: Agilent CDMA Base Station Over-Air Maintenance Toolliterature.cdn.keysight.com/litweb/pdf/5968-8696E.pdfAgilent CDMA Base Station Over-Air Maintenance Tool ... optimization platform

2

The purpose of this configuration guide is to assist you in ordering the correct system configuration for your application. It is designed to be used in conjunction with the Agilent CDMA Over-Air Maintenance Tool

Data Sheet (Agilent literature number 5968-8687E), which describes the features and functionality in detail. The Agilent CDMA Over-Air MaintenanceTool for IS-2000 is available as a receiver based system.

This document is divided into six parts:

Part 1. Basic description of product configuration

Part 2. Software options

Part 3. Receiver hardware options

Part 4. Accessories

Part 5. Upgrading existing systems

Part 6. Ordering examples

Part 6 provides the information required for upgrading existing systems. For example, if you currently own an Agilent E6474A wireless network optimization platform with only phone-based measurement capability, andyou want to upgrade it to have combined phone and receiver-based measurement capability, then the information in Part 6 will assist you inordering the necessary options.

Part 1. Basic description of product configuration

The E6474A system is made up of software, receiver hardware, and accessories. To order a system, you:

1. Choose the software functionality that you want (option numbers in the 150’s).

2. Choose the receiver hardware that you want (from E645XC family).

3. Choose the accessories that you want (Agilent 86154A and E6473Adrive test system accessories).

Each system requires an Agilent digital receiver. The system also requires aPC with Windows® 95, 98, Windows® ME, NT, or 2000 running the measure-ment software. A GPS receiver and GPS antenna are required to log the posi-tion information and provide timing for the receiver CDMA measurements.IMPORTANT: At least one software option and receiver must be ordered forthe product configuration to be valid.

Windows® 95, 98, and NT® are U.S. registered trademarks of Microsoft Corporation.

Page 3: Agilent CDMA Base Station Over-Air Maintenance Toolliterature.cdn.keysight.com/litweb/pdf/5968-8696E.pdfAgilent CDMA Base Station Over-Air Maintenance Tool ... optimization platform

3

Figure 1 illustrates the process of choosing the specific options to order with your Agilent E6474A system.

Figure 1. Ordering decision process – new systems

Decide what system

functionality you want

Place order

Choose software

license

Choose receiver

hardware

Choose

drive test

accessories

Agilent

E6474A

Option 1xx

Option 150

code domain power and

spectrum mask

These receivers include an

internal GPS receiver.

If desired, an external GPS

receiver may be used instead.

Agilent

E645XC

receiver

86154A Option 010

laptop PC

86154A Option 230

differential GPS receiver

86154A Option 531

briefcase carrier

E6473A Option 010

vehicle-mounted USB hub kit

E6452C

cellular band receiver

86154A Option 210

external GPS receiver with

dead reckoning

E6457C

Japan cellular band receiver

E6453C

Korea PCS band receiver

E6454C PCS band

CDMA/GSM receiver

E6456C PCS band

cdma2000/UMTS receiver

E6450C

PCS band receiver

Page 4: Agilent CDMA Base Station Over-Air Maintenance Toolliterature.cdn.keysight.com/litweb/pdf/5968-8696E.pdfAgilent CDMA Base Station Over-Air Maintenance Tool ... optimization platform

4

Part 2. Software options

This part of the document assumes that you are building a new system. If you are adding functionality to an existing system, refer to Part 5,Upgrading existing systems.

The following software options are available for the Agilent CDMA Over-AirMaintenance Tool:

• Option 150: cdmaOne and cdma2000 1x code domain power and spectrummask software license

Use Table 1 to determine which software option(s) you require for your application. For a detailed description of the functionality, please refer to the Agilent CDMA Over-Air Maintenance Tool Data Sheet (Agilent literature number 5968-8687E).

Desired functionality Software option(s) required

cdmaOne and cdma2000 1x code domain power 150

measurements and IS-97 spectrum mask capability

Each software order includes the following components:

• CD with software and documentation

• Getting Started Guide

• software license key (attaches to PC parallel or USB port)

Table 1. Software functionality

Page 5: Agilent CDMA Base Station Over-Air Maintenance Toolliterature.cdn.keysight.com/litweb/pdf/5968-8696E.pdfAgilent CDMA Base Station Over-Air Maintenance Tool ... optimization platform

5

Part 3. Receiver hardware options

This part of the document assumes that you are building a new system. If you are adding functionality to an existing system, refer to Part 5,Upgrading existing systems.

The following digital receiver hardware options are available for the CDMA Over-Air Maintenance Tool:

• E6452C: Cellular band digital receiver with internal GPS receiver • E6450C: PCS band CDMA/TDMA digital receiver with internal

GPS receiver• E6457C: Japan cellular band receiver with internal GPS receiver• E6453C: Korea PCS band receiver with internal GPS receiver• E6454C: PCS band CDMA/GSM receiver• E6456C: PCS band cdma2000/UMTS receiver

Software Option 150 is required to operate Agilent receivers. One softwarepackage can control up to four receivers.

Internal GPS provides portability and simplifies system configuration. If yourequire dead reckoning with your GPS, use an external GPS receiver.

Agilent RF E645XC receivers come with internal GPS or an external GPS canbe added. Agilent offers an external GPS with dead reckoning capability. Refer to Part 4, Accessories.

For receiver specifications and a detailed description of the receiver functionality, please refer to the Agilent CDMA Over-Air Maintenance Tool

Data Sheet (Agilent literature number 5968-8687E).

Select the receiver that covers the frequency band in which you want tomake measurements. If you need to make measurements in more than oneband, order multiple measurement receivers.

Each receiver includes the following components:

• magnetic-mount RF antenna for the corresponding frequency band• TNC-to-type N adapter for RF antenna• RS-232 cable for connection to PC1

• cable for connecting in multiple receiver configuration• AC/DC power supply1

• DC power cord (cigarette lighter type)1

• mounting kit (brackets and screws for mounting receiver in a vehicle)• magnetic-mount GPS antenna with cable

1 Alternatively, Agilent provides optional system accessories that can be used to power and connect simultaneously up to

two phones and up to two receivers to the PC. The E6473A option 010 (vehicle-mounted USB hub kit) is provided for drive

testing (in-vehicle) environments. Refer to Part 4: Accessories

Page 6: Agilent CDMA Base Station Over-Air Maintenance Toolliterature.cdn.keysight.com/litweb/pdf/5968-8696E.pdfAgilent CDMA Base Station Over-Air Maintenance Tool ... optimization platform

6

Part 4. Accessories

Accessories for the Agilent CDMA Over-Air Maintenance Tool are orderedusing the Agilent 86154A or E6473A model numbers. This model number pro-vides an easy way to order accessories. Table 2 lists the accessories that are available. Items in column 1 would typically be ordered with a new E6474Asystem. Items in column 2 would typically be ordered as replacement parts,as these elements are included with new systems.

E6474A Optional system accessories E6474A Replacement accessories

Agilent 86154A Agilent 86154A

Option 010: Laptop PC Option 099: Multiple receiver

interconnect kit

Option 210: Trimble Placer GPS 455 with Option 410: PCS band magnetic-mount

dead reckoning RF antenna

Option 230: Differential GPS receiver Option 430: Cellular band magnetic-

mount RF antenna

Option 531: Briefcase carrier Option 510: Vehicle mounting kit

E6473A Accessories

Option 010: Vehicle-mounted USB hub kit

Table 2. Accessories

For a detailed description of these accessories, please refer to the Agilent

CDMA Over-Air Maintenance Tool Data Sheet (Agilent literature number5968-8687E).

Page 7: Agilent CDMA Base Station Over-Air Maintenance Toolliterature.cdn.keysight.com/litweb/pdf/5968-8696E.pdfAgilent CDMA Base Station Over-Air Maintenance Tool ... optimization platform

7

Part 5. Upgrading existing systems

The Agilent E6474A is a scalable system. You can start with one set of capabilities and integrate additional capabilities later. For example:

• Start with a receiver-based system and upgrade later to include phone-based measurements.

The system is made up of software, receiver hardware, and accessories.Upgrading a system is similar to building a new system. You simply order those system elements that you don’t currently have. To upgrade a system:

1. Decide what system capability you want.

2. Identify the capability you currently have.

3. Choose the software options that you need to add (option numbers in the 150’s).

4. Choose the hardware options that you need to add (E645XC receivers).

5. Choose the accessories that you need to add (Agilent 86154A and E6473A drive test system accessories).

Figure 2 illustrates the process of choosing the specific options to orderwhen you are upgrading an Agilent E6474A system.

The CDMA Over-Air Maintenance Tool system is completely scalable with theAgilent E6474A CDMA drive test system. For more information on relatedproducts, please refer to the literature listed at the end of this document.

Upgrading existing cdmaOne systems

If you own an older E7490A or E7473A cdmaOne system and would like toupgrade receiver hardware and/or system software to cdma2000 1x capabili-ty, choose from the following options:

• 86157A - Upgrades E6450B or E6452A receiver to higher per-formance C version. Upgrades E7473A Option 111or E7490A Option 111 code domain power softwarefor cdma2000 1x measurements.

• E6474A Option 151 - Upgrades E7473A Option 111 or E7490A Option 111code domain power software for cdma2000 1x mea-surements (software requires C version receiver forthese measurements).

• 86150C - Upgrades E6450B or E6452A receiver to higher per-formance C version.

Page 8: Agilent CDMA Base Station Over-Air Maintenance Toolliterature.cdn.keysight.com/litweb/pdf/5968-8696E.pdfAgilent CDMA Base Station Over-Air Maintenance Tool ... optimization platform

8

Figure 2. Upgrade ordering decision process

Identify the capability

you currently have

Decide what system

functionality you want

Place order

Choose software

license

Choose receiver

hardware

Choose

drive test

accessories

Agilent

E6474A

Option 1xx

Agilent

E645XC

Option 151

code domain power and

spectrum mask

86154A Option 010

laptop PC

86154A Option 230

differential GPS receiver

86154A Option 531

briefcase carrier

E6473A Option 010

vehicle-mounted USB hub kit

86154A Option 210

external GPS receiver with

dead reckoning

E6452C

cellular band receiver

E6457C

Japan cellular band receiver

E6453C

Korea PCS band receiver

E6454C PCS band

CDMA/GSM receiver

E6456C PCS band

cdma2000/UMTS receiver

E6450C

PCS band receiver

Page 9: Agilent CDMA Base Station Over-Air Maintenance Toolliterature.cdn.keysight.com/litweb/pdf/5968-8696E.pdfAgilent CDMA Base Station Over-Air Maintenance Tool ... optimization platform

9

Desired system capability What to order Description Quantity

Code domain power and spectrum mask system E6474A CDMA Over-Air Maintenance Toolfor the cellular band with internal GPS. Option 150 Code domain power and spectrum mask SW 1Carrying case for the system. E6452C Cellular receiver with internal GPS 1You will provide your own laptop.

86154A Drive system accessoriesOption 531 Briefcase carrier 1

Code domain power and spectrum mask E6474A CDMA Over-Air Maintenance Toolfor the PCS band. Powered cable for Option 150 Code domain power and spectrum mask SW 1QCP2700. You want a laptop PC included E6450C PCS receiver 1with the system.

86154A Drive system accessoriesOption 010 Laptop PC 1Option 531 Briefcase carrier 1

E6473A Drive system accessoriesOption 010 Vehicle-mounted USB hub kit 1Option 801 Interface cable for QCP820/1920/2700 1

Code domain power for IS-2000 and 86157A Provides software and hardware 1spectrum mask (you already own a upgrade as described on page 7cdmaOne receiver-based system).

Table 3. Typical ordering configurations

Part 6. Ordering examples

Table 3 lists several typical Agilent CDMA Over-Air Maintenance Tool systemconfigurations along with the products and options that must be ordered foreach configuration. This is not a complete list of all possible configurations,but it includes typical configurations to illustrate the ordering process.

Page 10: Agilent CDMA Base Station Over-Air Maintenance Toolliterature.cdn.keysight.com/litweb/pdf/5968-8696E.pdfAgilent CDMA Base Station Over-Air Maintenance Tool ... optimization platform

10

Additional Agilent literature

Product overviews

CDMA Over-Air Maintenance Tool Product Overview ............5968-8697E

E6474A Wireless Network Optimization Platform

Product Overview......................................................................5988-3558EN

OPAS32 Engineering Information Management

and Analysis Software Product Overview ..............................5988-0247EN

Direct Connect Hub Product Overview ....................................5988-3176EN

Configuration guides

E6474A Wireless Network Optimization Platform

Configuration Guide ................................................................5988-2396EN

OPAS32 Engineering Information Management

and Analysis Software Configuration Guide ..........................5988-1589EN

Data sheets

CDMA Over-Air Maintenance Tool Data Sheet ........................5968-8687E

E7473A CDMA Drive Test System Data Sheet ........................5968-5555E

Product Notes

CDMA Drive Test Product Note ................................................5968-5554E

Using Agilent E7473A CDMA

Drive Test System Product Note ..............................................5988-0896EN

Application Notes

Optimizing your CDMA Wireless Network Today

and Tomorrow Using Drive Test Solutions

Application Note - 1345............................................................5968-9916E

Page 11: Agilent CDMA Base Station Over-Air Maintenance Toolliterature.cdn.keysight.com/litweb/pdf/5968-8696E.pdfAgilent CDMA Base Station Over-Air Maintenance Tool ... optimization platform

11

Page 12: Agilent CDMA Base Station Over-Air Maintenance Toolliterature.cdn.keysight.com/litweb/pdf/5968-8696E.pdfAgilent CDMA Base Station Over-Air Maintenance Tool ... optimization platform

Agilent Technologies’ Test and Measurement Support,

Services, and Assistance

Agilent Technologies aims to maximize the value youreceive, while minimizing your risk and problems. Westrive to ensure that you get the test and measurementcapabilities you paid for and obtain the support youneed. Our extensive support resources and services canhelp you choose the right Agilent products for yourapplications and apply them successfully. Every instrument and system we sell has a global warranty.Support is available for at least five years beyond theproduction life of the product. Two concepts underlieAgilent's overall support policy: "Our Promise" and"Your Advantage."

Our Promise

Our Promise means your Agilent test and measurementequipment will meet its advertised performance andfunctionality. When you are choosing new equipment,we will help you with product information, includingrealistic performance specifications and practical recommendations from experienced test engineers.When you use Agilent equipment, we can verify that itworks properly, help with product operation, and provide basic measurement assistance for the use ofspecified capabilities, at no extra cost upon request.Many self-help tools are available.

Your Advantage

Your Advantage means that Agilent offers a wide rangeof additional expert test and measurement services,which you can purchase according to your unique technical and business needs. Solve problems efficient-ly and gain a competitive edge by contracting with usfor calibration, extra-cost upgrades, out-of-warrantyrepairs, and on-site education and training, as well asdesign, system integration, project management, andother professional engineering services. ExperiencedAgilent engineers and technicians worldwide can helpyou maximize your productivity, optimize the return oninvestment of your Agilent instruments and systems,and obtain dependable measurement accuracy for thelife of those products.

By internet, phone, or fax, get assistance with all your

test & measurement needs

Online assistance:

www.agilent.com/find/assist

Phone or Fax

United States:(tel) 1 800 452 4844

Canada:(tel) 1 877 894 4414(fax) (905) 282-6495

China:(tel) 800-810-0189

(fax) 1-0800-650-0121

Europe:(tel) (31 20) 547 2323(fax) (31 20) 547 2390

Japan:(tel) (81) 426 56 7832(fax) (81) 426 56 7840

Product specifications and descriptions in this document subject to change without notice.Copyright © 2001 Agilent TechnologiesPrinted in U.S.A. August 30, 20015968-8696E

Korea:(tel) (82-2) 2004-5004 (fax) (82-2) 2004-5115

Latin America:(tel) (305) 269 7500(fax) (305) 269 7599

Taiwan:(tel) 080-004-7866 (fax) (886-2) 2545-6723

Other Asia Pacific Countries:(tel) (65) 375-8100 (fax) (65) 836-0252Email: [email protected]

For more information about related products, applications, and services visit our Web site:

www.agilent.com/find/basestations


Top Related