dilution extractive cems - cemtek environmental · dilution extractive cems dilution extractive,...

2
Features & Benefits www.cemteks.com Dilution Extractive CEMS Dilution Extractive, wet basis measurement design Carefully selected measurement technology for your specific application Open panels, analyzers and parts arrangement for easy access and custom applications Modular design allows for ease of adding or removing analyzer, flow monitor, opacity and particulate Coal, biomass and other industrial applications measured Boilers, turbines, furnaces, incinerators and heaters for the power generation, hospitals, universities, refineries, glass and other industrial applications Accurate. Reliable. Cost Effective. A Ac Ac c c A Ac c Ac c Accurate. Reliable. Cost Effective. Emissions Monitoring for Compliance & Process Improvement

Upload: others

Post on 28-Mar-2020

37 views

Category:

Documents


1 download

TRANSCRIPT

Features & Benefits

www.cemteks.com

Dilution Extractive CEMS

Dilution Extractive, wet basis measurement design

Carefully selected measurement technology for

your specific application

Open panels, analyzers and parts arrangement

for easy access and custom applications

Modular design allows for ease of adding or removing

analyzer, flow monitor, opacity and particulate

Coal, biomass and other industrial applications measured

Boilers, turbines, furnaces, incinerators and heaters for

the power generation, hospitals, universities, refineries,

glass and other industrial applications

Accurate. Reliable. Cost Effective.AAcAcccAAccAccAccurate. Reliable. Cost Effective.

Emissions Monitoring for Compliance & Process Improvement

Accurate. Reliable. Cost Effective.Emissions Monitoring for Compliance & Process Improvement

Accurate. Reliable. Cost Effective.At Cemek Environmental, we are the CEMS integration, reporting and service experts. We have designed our CEMS with the service technician in mind. Our designs allow for ease of maintenance, reduced downtime and guaranteed certification, year after year. With sample system components easily accessible, it’s simple to follow your EPA QA/QC plan. Cemtek is your partner for start-up, training, certification and long term maintenance. Our parts experts are always available to meet all of your CEMS parts needs and our regulations experts ensure accurate, reliable reporting. Now, more than ever, it is easy for our customers to keep their long term costs low. With offices on each coast and a field technician network across the United States, we are ready to serve all industrial and utility plants. Our Southern California production facility offers over 14,000 SF of CEMS and shelter assembly space. In Linden, New Jersey, our 6,500SF east coast facility services the greater Northeast.

Sample Probe:

Product Specifications

Sample Line:

Sample Conditioning System:

Analyzers:

Controller:

Enclosures:

Other Options:

Cemtek Environmental CEMS Solutions Accurate. Reliable. Cost Effective.

3041 S. Orange Avenue, Santa Ana, California 92707(888) 400-0200 (Toll Free) | email: [email protected] www.cemteks.com

« Standard 1.5 meter unless specified « Hastelloy and other material available for temps over 700o F « Purge/blowback on particulate laden flue gas « Pressure and temperature compensation standard dilution probe features« Initial filtration in heated filter assembly enclosure

« 3/8” sample tube in all bundles« 1/8” cal tube where applicable« Application dependant« Eductor air, isolation valve, pressure and compensation tubes standard in 7 tube design« Spare tubes optional« Isolation valve, pressure/temp compensation or spare tubes available « All tubes, power and signal wires will mate with probe selected above

« Extremely low sample volume ensures minimal plugging and transport issues for reliable long term operation between maintenance intervals« Pressure and temperature compensation is critical to dilution design« Custom design available for inlet SCR, Scrubber and wet stack applications« Wet design means no moisture measurement or correction factor for mass emission reporting« Multiple Sample System in one cabinet or shelter

« Standard measurements include: NOx, CO, CO2, O2, SO2, NH3, HCl, VOC’s« Analyze using traditional or FTIR, TDL and GC (application specific) « Flexibility of design includes experience with many types of analyzers« Daily auto calibration meets EPA requirements« ABB, Ametek, Brand Gaus,CAI, Durag, EMRC, Kurz, Land, Rosemount, Servomex, Sick Maihak, Siemens, T-API, Thermo Fisher, TMLI, Unisearch, Western Research « Allen Bradley, GE, Modicon PLC’s, Data Loggers 8832 (other options available)« Standard alarm, calibration package and data transmission, diagnostic features that help to prevent or minimize down time « 7 day data storage backup« Optional OIT’s (Operator Interface Terminals)

« Flexible design for cabinets « NEMA 12, 3R, 4X, stainless steel or fiberglass« Compact for space constraints « Single or redundant HVAC units« Single bay available « Walk-in shelters: standard design or custom « Dual bay standard for 1-2 CEMS

« UPS « DAHS - Data Acquisition and Handling System« Chart Recorder « USEPA 60/75, all state and local regulations « Transformer « Plant air refrigeration, drying and filtering systems « Class I, Div II, CSA, UL (electrical options)