1
1. Measuring Surfaces for Outside Measurements12. Measuring Surfaces for Step Measurements 3. Measuring Surfaces for Inside Measurements14. Lock Screw 5. LCD Display 6. Scale 7. Depth Bar 8. Scale 9. Battery Cover 10. [ZERO] Button 11. [ON / OFF] Button 12. [Hold] Button 13. Output Connector214. Thumb Wheel (*1D-150W, D-200W, D-300W models have a carbide measuring surface for inside, and outside measurements. (*2Output connector function not available for this model. Before use, please wipe off corrosion protectant using a soft, oiled cloth. This is a precision instrument, handle with care. Do not drop or subject to excessive force. Do not damage scale or scratch instrument. Do not apply ID numbers with engraver. Keep away from direct sunlight. Do not store instrument in extreme temperatures. Thank you for purchasing Digital Calipers. Before use, please read this document thoroughly for proper operation. PARTS IDENTIFICATION OPERATION Q. Nothing is displayed, or the numbers are flashing. A. Is the battery running low? Q. With power on, the number on the LCD does not change as main slide is moved. A. Please reset by removing battery for about 30sec., and then replacing. Q. Nothing happens when buttons are pressed. A. Is the battery inserted properly? Q. The characters “MIN”, “MAX”, or “” are displayed on LCD. A. Cycle power, or apply several long presses to [HOLD] button. Use as normal once character is off. Niigata seiki Co., Ltd. 6-15-22, Tsukanome, Sanjo, Niigata, Japan, 955-0055 Tel. : +81-256-31-5660 Fax. : +81-256-39-7730 MAIL:[email protected] URL http://www.niigataseiki.co.jp Resolution : 0.01mm Instrument Error : DT-100/DT-150/DT-200/D-150W/D-200W ±0.03mm DT-300/D-300W ……………………………… ±0.04mm Display : 5-Digit LCD Maximum Response Speed : Moving Slide to Right :1.5m/s Moving Slide to Left : 0.75 m/s “Right” and “Left” when viewed as shown in Parts Identification drawing. Operating Temperature Range : 040Storage Temperature Range : -1060Power : Silver Oxide Battery, SR44, 1.55V Battery Life : Approx. 1 year with normal usage Accessories : Silver Oxide Battery, SR44, 1.55V, (for testing.) I228-K 1502 1. Slide cover in direction of arrow. 2. Insert battery with () side outward. 3. Replace battery cover. Absolute Measurement1. Turn on power. 2. Press [ZERO] button with caliper jaws fully closed. 3. When display reads “0.00mm”, caliper is ready for use. Relative Measurement1. Turn on power. 2. Open the caliper jaws to desired reference value and press [ZERO] button (OK at any position). 3. When display reads “0.00mm”, caliper is ready for use. Battery Cover BATTERY REPLACEMENT Only use SR44 type battery. TROUBLESHOOTING OPERATION SPECIFICATIONS Open 2 4 12 5 13 6 1 3 11 10 9 14 8 7 Use care to prevent the thumb wheel from coming loose when jaws are fully opened. Notice Notice Model No. : DT- *** / D- *** W<combined> INSTRUCTION MANUAL DIGITAL CALIPERS

Upload: vodung

Post on 14-Jul-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DIGITAL CALIPERS INSTRUCTION MANUAL - 新潟精機 … · Thank you for purchasing Digital Calipers. ... Press [ZERO] button with caliper jaws fully closed. 3. When display reads

1. Measuring Surfaces for Outside Measurements(*1)

2. Measuring Surfaces for Step Measurements

3. Measuring Surfaces for Inside Measurements(*1)

4. Lock Screw 5. LCD Display 6. Scale 7. Depth Bar

8. Scale 9. Battery Cover10. [ZERO] Button11. [ON / OFF] Button12. [Hold] Button13. Output Connector(*2)

14. Thumb Wheel

(*1)D-150W, D-200W, D-300W models have a carbide measuring surface for inside, and outside measurements.

(*2)Output connector function not available for this model.

・Before use, please wipe off corrosion protectant using a soft, oiled cloth.・This is a precision instrument, handle with care. Do not drop or subject to excessive force.・Do not damage scale or scratch instrument. Do not apply ID numbers with engraver.・Keep away from direct sunlight. Do not store instrument in extreme temperatures.

Thank you for purchasing Digital Calipers.Before use, please read this document thoroughly for proper operation.

PARTS IDENTIFICATION

OPERATION

Q. Nothing is displayed, or the numbers are flashing. A. Is the battery running low?Q. With power on, the number on the LCD does not change as main slide is moved. A. Please reset by removing battery for about 30sec., and then replacing.Q. Nothing happens when buttons are pressed. A. Is the battery inserted properly?Q. The characters “MIN”, “MAX”, or “△” are displayed on LCD. A. Cycle power, or apply several long presses to [HOLD] button. Use as normal once character is off.

Niigata seiki Co., Ltd.6-15-22, Tsukanome, Sanjo, Niigata, Japan, 955-0055Tel. : +81-256-31-5660 Fax. : +81-256-39-7730MAIL:[email protected] http://www.niigataseiki.co.jp

・Resolution : 0.01mm・Instrument Error : DT-100/DT-150/DT-200/D-150W/D-200W …±0.03mm DT-300/D-300W ………………………………±0.04mm・Display : 5-Digit LCD・Maximum Response Speed : Moving Slide to Right :1.5m/s Moving Slide to Left : 0.75 m/s ※ “Right” and “Left” when viewed as shown in Parts Identification    drawing.・Operating Temperature Range : 0℃~40℃・Storage Temperature Range : -10℃~60℃・Power : Silver Oxide Battery, SR44, 1.55V・Battery Life : Approx. 1 year with normal usage・Accessories : Silver Oxide Battery, SR44, 1.55V, (for testing.)

I228-K 1502

1. Slide cover in direction of arrow.

2. Insert battery with (+) side outward.3. Replace battery cover.

<Absolute Measurement> 1. Turn on power. 2. Press [ZERO] button with caliper jaws fully closed. 3. When display reads “0.00mm”, caliper is ready for use.

<Relative Measurement> 1. Turn on power. 2. Open the caliper jaws to desired reference value and press [ZERO] button (OK at any position). 3. When display reads “0.00mm”, caliper is ready for use.

Battery Cover

BATTERY REPLACEMENT

Only use SR44 type battery.

TROUBLESHOOTING

OPERATION

SPECIFICATIONS

Open

2 4 125 13 6

1

3

11 10 9 14 8 7

Use care to prevent the thumb wheel from coming loose when jaws are fully opened.

Notice

Notice

Model No. : DT-*** / D-***W<combined>

INSTRUCTION MANUALDIGITAL CALIPERS