dc contactors - allpowersource

15
Visit : www.theallpowersource.com E-mail : [email protected] DC CONTACTORS DC CONTACTORS

Upload: dallyman47

Post on 18-Aug-2015

237 views

Category:

Documents


1 download

DESCRIPTION

DC contactors made by TheAllPowerSource come with either bolt or bus bar design and are used in power supplies, DC UPS and battery chargers.

TRANSCRIPT

Visit : www.theallpowersource.comE-mail : [email protected] CONTACTORS DC CONTACTORS100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] Allpower Source (TAS) is a division of Technology Dynamics Inc. (TDI) in Bergenfeld NJ, with 3 modern facilities totaling over 50,000 square feet and over 100 dedicated employees. Established in 1976, Technology Dynamics Inc. is a leading manufacturer of standard, modifed and fully custom Switching Power Supplies and DC-DC Converters for both commercial and military applications. The Allpower Source division specializes in engineering, manufacturing and distribution ofspecialized components for the power supply industry. Its product mix spans the range of electrical, electromechanical andmechanicalitemsspecifcallytargetedtothepowersupply,militaryandcommercialindustry. TAS ofers products and services at extremely competitive prices and quick delivery to power supply engineers often unable to get custom parts such as heatsinks or EMI flters at low prices, and quick turn around. TAS products are deployed in the most advanced military systems. TAS products are used in power systems which were fully qualifed to MIL-STD-461, MIL-STD-810 and MIL-STD-1399. TAS products are either imported from all over the world or manufactured in America. Custom parts are made with very low tooling cost and in just a few weeks. Non-custom parts are mostly from stock or 2 weeks delivery. Very broad line of products not readily available in the USA. We are here to serve the power supply exclusively.Facility of Electronic Integration Technologya subsidiary of Technology Dynamics Inc.ABOUT USThe Allpower Source ofers line of DC contractors in the range of 50A to 1500A with either bolt or bus bar design.APPLICATIONS Electronic equipment Power Supplies Power Conversion Equipment DC UPS Battery Chargers These devices are equipped with coil voltages of 12V, 24V, 48V, 60V, 110V, and other voltages on request. Optional auxiliary switch is available. Most models are available from stock. Devices in the range 50A 800A are UL approved. Very rugged construction. Comes with mounting brackets.50 - 1500 A SUITABLE FOR MILITARY SYSTEMS1500 A100 AIII100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] Contactor RelayTCR50SAmpere Frame(AF) 50AFPart No. TCR50SRated insulation voltage(Ui) 250 VDCRated operating voltage(Ue)60 VDCPoles 1Rated Current(In) (A) 50 AVoltage Drop(mV) 50 mV at 100 AOperating Voltage(V) Min. 12 VDC ~ Max. 220 VDCPull-in Voltage(V) Under 75% of operating voltageDrop-out Voltage(V)Power Loss(W) 5 ~ 7WAux. Switch 4 A at 24 VDC1A at 60 VDC 0.5A at 125 VDCConnections Bolt on TypeOperating MethodStandard(1a) [SPST] Change Over(1a1b) [SPDT] Magnetically LatchingNumber of operating cycle(10,000)Without Current 100With Current 10Auxiliary Switch(Optional) 1CMounting positionof Aux. contactSide on -Head on Aux. Contact rating(A)24 VDC 448 VDC 260 VDC 1DimensionW H D [mm] 3 x 3.7 x1.97 [78 94.5 50]Installation[mm] 0.6 x 2.6[15 65]Mounting Method ScrewWeight [kg] 0.89 lb [0.4]Coil VoltageMin. 12 VDC ~ Max. 220 VDCApproval Standard UL Contact Performance (Intermittent Ratings) Dimensions (mm)9005004504003503002502001501005000 50 75 100 125 150 175 200 225(seconds)(Amperes)50A ContinuousCONTACT PERFORMANCE Connection Diagrams2.56 [65]0.82 [21]0.6 [15]3.07 [78]2.56 [65]0.6 [15]MAX 3.39 [86]1.54 [39]0.75 [19]0.6 [15]MAX 1.97 [50]0.63 [16]0.63 [16]1.10 [28]MAX3.19 [81]0.65 [16.5]0.65 [16.5]0.06 [1.5]0.23 [6]2.56 [65]0.82 [21]3.07 [78]0.6 [15]2.56 [65]0.6 [15]MAX 3.39 [86]1.54 [39]0.75 [19]0.6 [15]0.99 [23.5]0.65 [16.5]0.65 [16.5]MAX3.19 [81]1.10 [28]0.63 [16]0.06 [1.5]0.63 [16]0.23 [6]Standard Type, Magnetically Latching TypeChange Over Type,Magnetically Latching TypeSPST & Magnetically LatchingSPDT & Magnetically Latching12100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] Contactor RelayTCR80STCR100STCR125SAmpere Frame(AF) 125AFPart No. TCR80S TCR100S TCR125SRated insulation voltage(Ui)250 VDCRated operating voltage(Ue)60 VDCPoles 1Rated Current(In) 80 A 100 A 125 AVoltage Drop(mV) 50 mV at 100 AOperating Voltage(V) Min. 12 VDC ~ Max. 220 VDCPull-in Voltage(V) Under 75% of operating voltageDrop-out Voltage(V) Under 75% of operating voltagePower Loss(W) 5 ~ 7 WAux. Switch 4A at 24VDC 1A at 60VDC 0.5A at 125VDCConnections Bolt on TypeOperating MethodStandard(1a) [SPST] Change Over(1a1b) [SPDT] Magnetically LatchingNumber of operating cycle(10,000)Without Current 100With Current 10Auxiliary Switch(Optional) 1CMounting positionof Aux. contactSide on - - -Head onAux. Contact rating(A)24 VDC 448 VDC 260 VDC 1DimensionW H D [mm] 3 x 3.7 x1.97 [78 94.5 50]Installation[mm] 0.6 x 2.6[15 65]Mounting Method ScrewWeight [kg] 0.89 lb [0.4]Coil VoltageMin. 12 V ~ Max. 220 VApproval Standard UL Contact Performance (Intermittent Ratings) Dimensions (mm)9005004504003503002502001501005000 50 100 150 200 250 300 350 400(seconds)(Amperes)80A100A125ACONTACT PERFORMANCE Connection Diagrams2.56 [65]0.2 [5.2]3.07 [78]MAX 1.77 [45]0.06 [1.5]1.44 [36.5]1.10 [28]0.6 [15]2.56 [65]0.6 [15]2.56 [65]MAX 3.74 [95]1.13 [28.5]0.6 [15]0.7 [18]0.64 [16.3]0.63 [16]MAX 1.97 [50]0.63 [16]1 [25.3]0.23 [6]2.56 [65]2.56 [65]0.6 [15]0.6 [15]3.07 [78]MAX 3.72 [94.5]0.75 [19]1.54 [39]2.18 [55.3]1.2 [30.5] 0.72 [18.3]1.12 [28.5]0.64 [16.3]0.7 [18]MAX 1.97 [50]1 [25.3]0.23 [6]0.31 [8]0.47 [12]Standard Type, Magnetically Latching TypeChange Over Type,Magnetically Latching TypeSPST & Magnetically LatchingSPDT & Magnetically Latching34100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] Contactor RelayTCR200SAmpere Frame(AF) 200AFPart No. TCR200SRated insulation voltage(Ui) DC(V) 250 VDCRated operating voltage(Ue)DC(V) 60 VDCPoles 1Rated Current(In) (A) 200 AVoltage Drop(mV) 50 mV at 100 AOperating Voltage(V) Min. 12 VDC ~ Max. 220 VDCPull-in Voltage(V) Under 75% of operating voltageDrop-out Voltage(V) Under 75% of operating voltagePower Loss(W) 5 ~ 7 WAux. Switch 4A at 24 VDC 1A at 60 VDC 0.5A at 125 VDCConnections Bolt on TypeOperating MethodStandard(1a) [SPST] Change Over(1a1b) [SPDT] Magnetically LatchingNumber of operating cycle(10,000)Without Current 100With Current 10Auxiliary Switch(Optional) 1CMounting positionof Aux. contactSide on -Head on Aux. Contact rating(A)24 VDC 448 VDC 260 VDC 1DimensionW H D [mm] 2.83 x 5.98 x 2.44 [7215262]Installation[mm] 3.78 x 6.18 x 2.44 [9615762]Mounting Method ScrewWeight [kg] 2.65 lb [1.2]Coil VoltageMin. 12 VDC ~ Max. 220 VDCApproval Standard UL Contact Performance (Intermittent Ratings) Dimensions (mm)400A300A200A90080070060050040030020010000 500 1000 1500 2000(Amperes)(seconds)CONTACT PERFORMANCE Connection Diagrams3.34 [85]2.80 [71]0.25 [6.5]2.80 [71]0.89 [22.5]1.42 [36]0.89 [22.5]0.25 [6.5]4.51 [114.5]1.99 [50.5]1.38 [35]MAX 5.19 [130]0.65 [16.5]0.71[18]1.50 [38]1.35 [34.5]0.63 [16]0.98 [25]3.34 [85]1.42 [36]2.80 [71]2.40 [61]0.89 [22.5]2.52 [64]0.25 [6.5]0.33 [8.3]0.1 [22.5]2.80 [71]0.25 [6.5]4.51 [114.5]1.99 [50.5]1.38 [35]2.58 [65.5]MAX 5.12 [130]0.65 [16.5]0.71[18]0.63[16]0.5[12.7]0.53[13.5]1.64 [41.5]1.38 [35]1 [25.4]Standard Type, Magnetically Latching TypeChange Over Type,Magnetically Latching TypeSPST & Magnetically LatchingSPDT & Magnetically Latching56100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] Contactor RelayTCR300STCR400S Contact Performance (Intermittent Ratings) Dimensions (mm)400A300A200A90080070060050040030020010000 500 1000 1500 2000(Amperes)(seconds)CONTACT PERFORMANCE Connection Diagrams1.5 [38]0.79 [20]1.08 [27.5]3.78 [96]3.15 [80]3.15 [80]0.79 [20]MAX 6.30 [160]5.35 [136]3.5 [88.7]3.84 [97.5]2.9 [73]1.6 [40]MAX 3.15 [80]3.09 [78.5]0.71[18]0.79[20]1 [25.4]MAX 2.44 [62]0.67[17]0.24 [6]1.5 [38]3.15 [80]0.79 [20]0.79 [20]1.08 [27.5]3.01 [76.5]0.41 [10.5]3.15 [80]0.79 [20]6.17 [6.17]1.60 [40]0.79 [20]3.78 [96]1 [25.4]3.09 [78.5]0.71 [18]1.54 [39] 1.76 [44.5]1.77 [45]1.5 [38]0.4 [10]Standard Type, Magnetically Latching TypeChange Over Type,Magnetically Latching TypeSPST & Magnetically LatchingSPDT & Magnetically LatchingAmpere Frame(AF) 400AFPart No. TCR300S TCR400SRated insulation voltage(Ui) 250 VDCRated operating voltage(Ue) 60 VDCPoles 1Rated Current(In) (A) 300 A 400 AVoltage Drop(mV) 50 mV at 100 AOperating Voltage(V) Min. 12 VDC ~ Max. 220 VDCPull-in Voltage(V) Under 75% of operating voltageDrop-out Voltage(V) Under 75% of operating voltagePower Loss(W) 5 ~ 7 WAux. Switch 4 A at 24 VDC 1 A at 60 VDC 0.5 A at 125 VDCConnections Bolt on TypeOperating MethodStandard(1a) [SPST]Change Over(1a1b) [SPDT]Magnetically Latching Number of operating cycle(10,000)Without Current 100With Current 10Auxiliary Switch(Optional) 1CMounting positionof Aux. contactSide on -Head onAux. Contact rating(A)24 VDC 448 VDC 260 VDC 1DimensionW H D [mm] 2.83 x 5.98 x 2.44 [72 x 152 x 62]Installation[mm] 3.77 x 6.18 x 2.44 [96 x 157 x 62]Mounting Method ScrewWeight [kg] 2.65 lb [1.2]Coil VoltageMin. 12 VDC ~ Max. 220 VDCApproval Standard UL78100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] Contactor RelayTCR200T / TE / TLAmpere Frame(AF) 200AFPart No. TCR100T / TE / TL TCR200T / TE / TLRated insulation voltage(Ui) DC(V) 250 VDCRated operating voltage(Ue)DC(V) 60 VDCPoles 1Rated Current(In) (A) 100 A 200 AVoltage Drop(mV) 50 mV at 100 AOperating Voltage(V) Min. 12 VDC ~ Max. 220 VDCPull-in Voltage(V) Under 75% of operating voltageDrop-out Voltage(V) Under 75% of operating voltagePower Loss(W) 5 ~ 7 WAux. Switch 4A at 24 VDC 1A at 60 VDC 0.5A at 125 VDCConnections Bolt on TypeOperating MethodStandard(1a) [SPST]Change Over(1a1b) [SPDT] - -Magnetically Latching Number of operating cycle(10,000)Without Current 100With Current 10Auxiliary Switch(Optional) 1CMounting positionof Aux. contactSide onHead on - -Aux. Contact rating(A)24 VDC 448 VDC 260 VDC 1DimensionW H D [mm]T:3.35 3.94 2.99TL:3.40 3.94 3.35TE:3.35 3.94 2.80T:[85 100 76] TL:[86.5 100 85] TE:[85 100 71]Installation[mm] 1.48 or 0.63 x 2.56[37.5 or 16 65]Mounting Method ScrewWeight [kg] 1.98 lb [0.9]Coil VoltageMin. 12 VDC ~ Max. 220 VDCApproval Standard UL Dimensions (mm)3.38 [86]1 [25.5]1.42 [36]1.38 [35]0.6 [15]2.76 [70]2.00 [51]2.77 [70.3]4.01 [102]Standard Type, Magnetically Latching Type Contact Performance (Intermittent Ratings)000070060000400,00,00|0000,00070|000|,0|00_(/mjzrzz){_(zzzznqz)|1/1 |[||||/|[200A100A Connection DiagramsSPST & Magnetically Latching1.54 [39]4.01 [102]2.57 [65.3]0.2 [5]0.79 [20]1.80 [45.5]2.24 [57]2.00 [51]0.33 [8.5] Standard Type, Magnetically Latching Type3.41 [86.5]1.38 [35]3.01 [76.5]3.37 [86.5]MAX 4.01 [102]0.77 [19.5]MAX 2.95 [75]2.43 [61.75]1.28 [32.5]Standard Type, Magnetically Latching Type TCR200T TCR200TE TCR200TL910100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] Contactor RelayTCR300T / TE / TLTCR400T / TE / TLAmpere Frame(AF) 400AFPart No. TCR300T / TE / TL TCR400T / TE / TLRated insulation voltage(Ui) 250 VDCRated operating voltage(Ue) 60 VDCPoles 1Rated Current(In) (A) 300 A 400 AVoltage Drop(mV) 50 mV at 100 AOperating Voltage(V) Min. 12VDC ~ Max. 220VDCPull-in Voltage(V) Under 75% of operating voltageDrop-out Voltage(V) Under 75% of operating voltagePower Loss(W) 5 ~ 7 WAux. Switch 4 A at 24 VDC 1 A at 60 VDC 0.5 A at 125 VDCConnections Bolt on TypeOperating MethodStandard(1a) [SPST]Change Over(1a1b) [SPDT] - -Magnetically Latching Number of operating cycle(10,000)Without Current 100With Current 10Auxiliary Switch(Optional) 1CMounting positionof Aux. contactSide onHead on - -Aux. Contact rating(A)DC 24V 4DC 48V 2DC 60V 1DimensionW H D [mm]T:3.35 3.94 2.99TL:3.40 3.94 3.35TE:3.35 3.94 2.80T:[85 100 76] TL:[86.5 100 85] TE:[85 100 71]Installation[mm] 1.48 or 0.63 x 2.56[37.5 or 16 65]Mounting Method ScrewWeight [kg] 2.65 lb [1.2]Coil Voltage Min. 12 VDC ~ Max. 220 VDCApproval Standard UL Dimensions (mm)1 [25.5]3.38 [86]0.75 [19]1.42 [36]1.38 [35]3.00 [76]2.00 [51]2.57 [65.3]MAX 4.02 [102]M8 x0.05 [1.25]Standard Type, Magnetically Latching Type Contact Performance (Intermittent Ratings)400A300A200A90080070060050040030020010000 500 1000 1500 2000(Amperes)(seconds)CONTACT PERFORMANCE Connection DiagramsSPST & Magnetically Latching1.8 [45.5]1.54 [39]2.25 [57]2.00 [51]2.80 [71]0.79 [20]1.8 [5]2.57 [65.3]4.02 [102]0.34[8.5]Standard Type, Magnetically Latching Type2.44 [62]3.38 [86.5]3.01 [76.5]3.07 [78]1.38 [35]MAX 3.94 [100]0.75 [19.5]3.40 [86.5]1.64 [41.55]1.28 [32.5] Standard Type, Magnetically Latching Type TCR300T TCR400T TCR300TE TCR400TE TCR300TL TCR400TL1112100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] Contactor RelayTCR100B / BE / MT / MHTCR200B / BE / MT / MH Dimensions (mm)6.02 [153]MAX 4.02 [102]5 [127]0.4 [10.5]2.76 [70]2.2 [56]1 [25.5]1.7 [50]2.72 [69]2.74 [69.5]0.2 [5]3.4 [85.5]Standard Type, Magnetically Latching Type Contact Performance (Intermittent Ratings)400A300A200A90080070060050040030020010000 500 1000 1500 2000(Amperes)(seconds)CONTACTPERFORMANCE500A Connection DiagramsSPST & Magnetically Latching5.04 [128.1]1.97 [50]1.13 [28.7]4 [101.6]1.77 [45] 1.6 [40]2.67 [68]0.7 [18]MAX 3.94 [100]0.3 [8.5]Standard Type, Magnetically Latching Type1.97 [50]3.07 [113]1.13 [25.4]3.45 [87.5]0.4 [10.3]4.02 [102]0.2 [5]2.74 [69.5]Standard Type, Magnetically Latching Type TCR100B TCR200B TCR100BE TCR200BE TCR100MT TCR200MT TCR100MH TCR200MHAmpere Frame(AF) 200AFPart No. TCR100B / BE / MT / MH TCR200B / BE / MT / MHRated insulation voltage(Ui) 250 VDCRated operating voltage(Ue) 60 VDCPoles 1Rated Current(In) 100 A 200 AVoltage Drop(mV) 50 mV at 100 AOperating Voltage(V) Min. 12 VDC ~ Max. 220 VDCPull-in Voltage(V) Under 75% of operating voltageDrop-out Voltage(V) Under 75% of operating voltagePower Loss(W) 5 ~ 7 WAux. Switch 4 A at 24 VDC 1 A at 60 VDC 0.5 A at 125 VDCConnections Busbar TypeOperating MethodStandard(1a) [SPST]Change Over(1a1b) [SPDT] - -Magnetically Latching Number of operating cycle(10,000)Without Current 100With Current 10Auxiliary Switch(Optional) 1CMounting positionof Aux. contactSide onHead on - -Aux. Contact rating(A)DC 24V 4DC 48V 2DC 60V 1DimensionW H D [mm]B:153 100 51 BE:128 100 51 MT,MH:103 100 51B:6 3.94 2 BE:5 3.94 2 MT,MH:4 3.94 2Installation[mm] 2.2 x 2.75 [56 70]Mounting Method ScrewWeight [kg] 2.20 lb [1]Coil VoltageMin. 12 VDC~Max. 220 VDCApproval Standard UL1314100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] Contactor RelayTCR300B / BE / MT / MHTCR400B / BE / MT / MHTCR500BEAmpere Frame(AF) 400AFPart No. TCR300B / BE / MT / MH TCR400B / BE / MT / MH TCR500BERated insulation voltage(Ui) DC(V) 250 VDCRated operating voltage(Ue)DC(V) 60 VDCPoles 1Rated Current(In) (A) 300 A 400 A 500 AVoltage Drop(mV) 50 mV at 100 AOperating Voltage(V) Min. 12 VDC ~ Max. 220 VDCPull-in Voltage(V) Under 75% of operating voltageDrop-out Voltage(V) Under 75% of operating voltagePower Loss(W) 5 ~ 7 WAux. Switch 4A at 24VDC 1A at 60VDC 0.5A at 125VDCConnections Busbar TypeOperating MethodStandard(1a) [SPST] Change Over(1a1b) [SPDT] - - -Magnetically LatchingNumber of operating cycle(10,000)Without Current 100With Current 10Auxiliary Switch(Optional) 1CMounting positionof Aux. contactSide on Head on - - -Aux. Contact rating(A)DC 24V 4DC 48V 2DC 60V 1DimensionW H D [mm]B:153 100 51 BE:128 100 51 MT,MH:103 100 51B:6 3.94 2 BE:5 3.94 2MT,MH:4.05 3.94 2Installation[mm] 2.2 x 2.75 [56 70]Mounting Method ScrewWeight[kg] 2.20 lb [1]zCoil Voltage Min. 12 VDC ~ Max. 220 VDCApproval Standard UL Dimensions (mm)6.02 [153]2.76 [70]2.72 [69]5 [127]1.97 [50]1 [25.5]2.2 [56]0.41 [10.5]3.37 [85.5]2.74 [69.5]MAX 4.02 [102]0.2 [5]Standard Type, Magnetically Latching Type Contact Performance (Intermittent Ratings)400A300A200A90080070060050040030020010000 500 1000 1500 2000(Amperes)(seconds)CONTACTPERFORMANCE500A Connection DiagramsSPST & Magnetically Latching1.77 [45]MAX 3.94 [100]MAX 3.68 [68]0.33 [8.5]1.97 [50]1.13 [28.7]5.04 [128.1]4 [101.6]0.7 [18]1.6 [40]Standard Type, Magnetically Latching Type1.97 [50]2.25 [57]1 [25.4]3.45 [87.5]4.45 [113]MAX 4.02 [102]0.2 [5]1.8 [45.9]2.76 [70]0.43 [10.8]0.43 [10.8] 1.48 [37.5]0.43 [10.8]2.74 [69.5]Standard Type, Magnetically Latching Type TCR300B TCR300B TCR300BE TCR400BE TCR500BE TCR300MT TCR400MT TCR300MH TCR400MH1516100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] Frame(AF) 600AF 800AFPart No. TCR600BE TCR600B TCR800BRated insulation voltage(Ui) 250 VDCRated operating voltage(Ue) 60 VDCPoles 1Rated Current(In)600 A 600 A 800 AVoltage Drop(mV) 50 mV at 100 AOperating Voltage(V) Min. 12 VDC ~ Max. 220 VDCPull-in Voltage(V) Under 75% of operating voltageDrop-out Voltage(V) Under 75% of operating voltagePower Loss(W) 5 ~ 7 WAux. Switch 4A at 24 VDC 1A at 60 VDC0.5A at 125 VDCConnections Busbar TypeOperating MethodStandard(1a) [SPST] Change Over(1a1b) [SPDT] - - -Magnetically LatchingNumber of operating cycle(10,000)Without Current 100With Current 10Auxiliary Switch(Optional) 1CMounting positionof Aux. contactSide on Head on - - -Aux. Contact rating(A)DC 24V 4DC 48V 2DC 60V 1DimensionW H D [mm]5.04 4.40 6.62 6.02 5.55 3.62[128 112 92] [153 141 92]Installation[mm]2.99 x 3.99 1.69 x 3.54[76101.5] [4390]Mounting Method ScrewWeight[kg] 3.53 lb [1.6] 3.97 lb [1.8]Coil Voltage[mm] Min. 12 VDC ~ Max.220 VDCApproval Standard ULDC Contactor RelayTCR600BETCR600BTCR800B Contact Performance (Intermittent Ratings) Dimensions (mm) Connection Diagrams3.62 [92]5.04 [128]4 [101.6]1.4 [35]1.97 [50]1.13 [28.7]3 [76]0.33 [8.5]0.25 [6.4]4 [101.6]0.7[18]2.30 [58.5]3 [76]0.25 x 0.03[6.3 x 0.8]1.13 [28.8]3.62 [92]1 [25.4]2.25 [57]1.38 [35]3.62 [92]2.25 [57]4.49 [114]6.02 [153]0.37 [9.5]MAX 5.60 [142]4.28 [108.6]1.75 [44.5]0.2 [5]4.28 [108.6]3.55 [90.2]1.70 [43]0.85[21.5]0.85[21.5]0.24 [6]1500A 1000A90080070060050040030020010000 500 1000 1500 2000 2500 3000(Amperes)(seconds)CONTACT PERFORMANCEStandard Type, Magnetically Latching TypeChange Over Type,Magnetically Latching TypeSPST & Magnetically Latching TCR600BE TCR600B TCR800B1718100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] Frame(AF) 1000AF 1500AF 1800AFPart No. TCR1000BE TCR1000B TCR1200BTCR1500BTCR1500BETCR1800BERated insulation voltage(Ui) DC(V) 250Rated operating voltage(Ue)DC(V) 60Poles 1Rated Current(In) (A) 1000 A 1000 A 1200 A 1500 A 1800 AVoltage Drop(mV) 50 mV at 100 AOperating Voltage(V) Min. 12 VDC ~ Max. 220 VDCPull-in Voltage(V) Under 75% of operating voltageDrop-out Voltage(V) Under 75% of operating voltagePower Loss(W) 5 ~ 7 WAux. Switch 4A at 24VDC 1A at 60VDC 0.5A at 125VDCConnections Bolt on TypeOperating MethodStandard(1a) [SPST] Change Over(1a1b) [SPDT] - - - - -Magnetically LatchingNumber of operating cycle(10,000)Without Current 100With Current 10Auxiliary Switch(Optional) 1CMounting positionof Aux. contactSide on Head on - - - - -Aux. Contact rating(A)DC 24V 4DC 48V 2DC 60V 1DimensionW H D [mm]5.04 x 4.60 x 3.62 B: 17015092 BE: 187116102[128 117 92] B: 6.70 x 5.90 x 3.62BE: 7.40 x 4.56 x 4.01Installation[mm]1.75 x 5.60 -[44.5142] -Mounting Method ScrewWeight[kg] 6.4 lb [2.9]Coil VoltageMin. 12 VDC ~ Max. 220 VDCApproval Standard ULDC Contactor RelayTCR1000B / BETCR1200BTCR1500B / BETCR1800BE Dimensions (mm)1.75 [44.5]0.47 [12]MAX 5.90 [150]4.5 [114.3]3.62 [92]2.24[57]1.38 [35]5.15 [131]6.69 [170]0.47 [12]0.41 [10.5]Standard Type, Magnetically Latching Type Contact Performance (Intermittent Ratings)1500A 1000A90080070060050040030020010000 500 1000 1500 2000 2500 3000(Amperes)(seconds)CONTACTPERFORMANCE Connection DiagramsSPST & Magnetically Latching6 [152.4]3.62 [92]1.75 [44.5]4.5 [114.3]0.41 [10.5]MAX 4.60 [117]0.39 [10]2.30 [58.5]2.99 [76]0.70 [18]1.13 [28.8]1 [25.4]2.24 [57]Standard Type, Magnetically Latching Type10T: 1500A12T: 1800A10T: 1500A12T: 1800A7.37 [187.3]3.94 [100]5.59 [142.2]0.41 [10.5]1.75 [44.5]1.38 [35]MAX 4.57 [116]2.30 [58.5]2.99 [76][6.3] x [0.8]0.25 x 0.030.70 [18]1.13 [28.8]1 [25.4]2.24 [57]Standard Type, Magnetically Latching Type TCR1000B TCR1200B TCR1500B TCR1000BE TCR1500BE TCR1800BE1920100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] Order CodeEx) TCR400D12S B1Rated Current50 50 A80 80 A100 100 A125 125 A200 200 A300 300 A400 400 A500 500 A600 600 A800 800 A1000 1000 A1200 1200 A1500 1500 A1800 1800 AOperating Voltage12 12 V24 24 V27 27 V30 30 V48 48 V54 54 V60 60 V80 80 V110 110 V220 220 VRated VoltageD DC 60 VTCR 400 12 DTerminal TypeS SCREW TERMINALT TERMINAL STANDARDTL TERMINAL 90 bendingTE TERMINAL (EES)TT TER. FIX Symmetry (EATON)TA TERMINAL Opposite location (ARFT)TH TERMINAL SCREW NoneB BUSBARBE BUSBAR (EES)BB 400AF 600BE 6.4tMT BUSBARM5 [5 x 50 x 48.5]MH BUSBAR 10.3[5 x 50 x 48.5]Bracket0 No BRACKET1BRACKETStandard (Vertical)2BRACKETSide Mount(Horizontal)3BRACKET(Side Mount 1)AUX S/WS NoneW OneW2 TwoS B 1Contact Confguration & MethodS STANDARDC CHANGE OVERL MAGNETIC LATCHCL CHANGE OVER & MAGNETIC LATCHB B CONTACT (Normal Close)Aux. Switch OPTION0 Standard1 LED WIRE : 195mm 557-OGR P/G:39-01-2060 (EES)2 LED WIRE : 300mm (Donga Elecomm)3 LED WIRE : 50mm TERMINAL : 6.3 X 0.8 (EES)4 LED WIRE : 100mm TERMINAL : 6.3 X 0.8 (EES)5 EATON (Right side SSM3133)6 EATON (Insulation plate, SSM3134)7 LED WIRE : 215mm 557-OGR P/G:39-01-2060 (EES)Coil Terminal OPTION0 Standard1 LED WIRE : 225mm 557-OGR P/G:39-01-2060 (EES)2 LED WIRE : 200mm (Donga Elecomm) Molex50513 LED WIRE : 100mm TERMINAL : 6.3 X 0.8 (EES)4 Tems5 Resistance 85 ELTEK SLOVAKIA6 LED WIRE : 245mm 557-OGR P/G:39-01-2060 (EES)7 LED WIRE : 150mm (Molex 51067-02)DiodeD StandardD1 Full DuplexS 00 DO No need to specify coil terminal option and diode in case of STANDARD TYPE.2122100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] ProtectorCBP3 PA - SeriesMINI PLUG TYPESuitableforsmallsized equipment and protector of power source circuit.CBP3 PS - SeriesMINI SIDE-SCREW TYPESuitableforsmallsized equipment and protector of power source circuit.CBP3 P - SeriesPLUG TYPESuitableforprotectorof powersourcewithplug type structure.CBP3 S - SeriesSIDE-SCREW TYPEApplicabletopressed screw terminal.CBP5 B - SeriesBOLT TERMINALMountabletobusbar, pressedterminaland other various circuits.