Page 2: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

MATERIAL SAFETY DATA SHEETANSMANN NiMH BATTERY

RUGGED AUTHORITY www.cord-ex.com

Page 3: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

TECHNICAL NOTICEThe information contained within is provided as a service to our customers and Revision no: 3 for their information only. The information and recommendations set forth herein Revision date: 2013 - 08 - 08 are made in good faith and are believed to be accurate at the date of preparation. Editor: Ansmann AG ANSMANN AG makes no warranty expressed or implied.

1. Product and Supplier Identification

Product Name: Ansmann NiMH BatteryType: Sealed rechargeable nickel-metal-hydride batteryModels/Types: Prismatic and round cellsElectrochemical System: Nickel hydroxide (positive electrode) Metal hydroxide (negative electrode) Potassium hydroxide (electrolyte)

Suppliers Germany Address: ANSMANN AG Industriestraße 10; 97959 Assamstadt; GermanyPhone/Fax: + 49 (0) 6294 42040 / + 49 (0) 6294 420444 Home/Email: ansmann.de / [email protected]

USA Address: ANSMANN USA Corporation 1001 Lower Landing Rd. Ste 101; Blackwood, NJ08012; USAPhone/Facsimile: +1 973 4395244 1012 / +1 973 2062006Email: [email protected]

United Kingdom Address: ANSMANN UK LTD. Units 11-20, RO24, Harlow Business Park, Harlow, Essex. CM19 5QB. UKPhone/Facsimile: +44 (0) 870 609 2233 / +44 (0) 870609 2234 Email: [email protected]

Hong Kong Address: ANSMANN Energy Int. LTD. Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road; Kwun Tong, kowloon; Hong-Kong Email: [email protected]

China Address: HuiZhou City ANSMANN Trading Co. LTD Da Lian Industrial Park, Rengtu Village Ruhu Town Huicheng District, 516169 Huizhou City Guangdong, China Email: [email protected]

Sweden Address: ANSMANN Nordic AB Victor Hasselblads Gata 11, 421 31 Västra Frölunda, Sweden Email: [email protected]

France Address: Ansmann Energy France 5, Place Copernic; Immeuble Boréal - Courcouronnes; F-91023 Evry Cedex; France

EMERGENCY CONTACT: For chemical emergency only (spill, leak, fire, exposure or accident) call CHEMTREC at: 800-424-9300 within the USA and Canada +1 703-527-3887 outside the USA and Canada Non-emergency calls cannot be serviced at this number.

RUGGED AUTHORITY www.cord-ex.com

Page 4: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

2. Hazards Identification

The rechargeable NiMH batteries described in this Product Safety Data Sheet are sealed units which are not hazardous when used according to the recommendations of the manufacturer and as long as their integrity is maintained.

Do not short circuit, puncture, incinerate, crush, force discharge or expose to temperatures above the declared operating temperature range of the product. Risk of fire or explosion.

Under normal conditions of use, the active materials and liquid electrolyte contained in the cells and batteries are not exposed to the outside, provided the battery integrity is maintained and seals remain intact. Risk of exposure only in case of abuse (mechanical, thermal, electrical) which leads to the opening of the valves and/or the rupture of the battery container. Electrolyte leakage or battery vent/explosion/fire may follow, depending upon the circumstances.

3. Composition and Informations on Ingredients

Each cell consists of a hermetically sealed metallic container containing a number of chemicals and materials of construction of which the following could potentially be hazardous upon release.

Ingredient Content CAS No. ACGIH (TLV) OSHA (PEL)

Nickel (Ni) (powder) 30 - 45% 7440-02-0 1 mg/m³ TWA 1 mg/m³ TWA

Nickel Hydroxide Ni(OH)²

20 - 30% 12054-48-7 1 mg/m³ TWA 1 mg/m³ TWA

Cobalt (Co) 1 - 5% 7440-48-4 0.1 mg/m³ TWA (as Co)

0.1 mg/m³ TWA (as Co)

Manganese (Mn) 1 - 3% 7439-96-5 0.2 mg/m³ TWA (asMn)

5 mg/m³ dust

ceiling limit

Zinc (Zn) < 3% 7440-66-6 10 mg/m³ TWA total dust

15 mg/m³ TWA total dust

Aluminum (Al) 0 - 2% 7429-90-50 10 mg/m³ metal dust 15 mg/m³ dust 5 mg/m³ respirable fraction

Lanthanum (Ln) < 10% 7439-91-0 none established none established

Cerium (Cer) < 10% 7440-45-1 none established none established

Neodymium (Nd) < 10% 7440-00-8 none established none established

Potassium Hydroxide (KOH)

5 - 10% 1310-58-3 2 mg/m³ ceiling limit none established

Sodium Hydroxide (NaOH)

0 - 5% 1310-73-2 2 mg/m³ ceiling limit 2 mg/m³ TWA

Lithium Hydroxide (LiOH)

0 - 4% 1310-65-2 none established none established

Stainless Steel (Fe) 15 - 30% 7439-89-6 none established none established

RUGGED AUTHORITY www.cord-ex.com

Page 5: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

4. Composition and Informations on Ingredients

In case of accumulator breakage or burst, please evacuate employees from the contaminated area and ensure maximal ventilation in order to break-up corrosive gas, smoke and unpleasant odours. If it occurs, by accident, following measures must be taken:

Inhalation: Provide fresh air. In severe cases obtain medical attention.

Skin Contact: Wash off skin thoroughly with water. Remove contaminated clothing and wash before re-use. In severe cases obtain medical attention.

Eye Contact: Irrigate thoroughly with water for at least 15 minutes.Lifting upper and lower lids, until no evidence of the chemical remains. Obtain medical attention.

Ingestion: Wash out mouth thoroughly with water. Do not induce vomiting or give food or drink. Seek medical attention immediately.

Further treatment: All cases of eye contamination, persistent skin irritation and casualities who have swallowed this substance or been affected by breathing its vapours should be seen by a doctor.

5. Fire Fighting Measures

If fire or explosion occurs when batteries are on charge, shut off power to charger.

In case of fire where nickel metal hydride batteries are present, apply a smothering agent such as METL-X, sand, dry ground dolomite, or soda ash, or flood the area with water. A smothering agent will extinguish burning nickel metal hydride batteries. Water may not extinguish burning batteries but will cool the adjacent batteries and control the spread of fire. Burning batteries will not burn themselves out. Virtually all fires involving nickel metal hydride batteries can be controlled with water. When water is used, however, hydrogen gas may evolve. In a confined space, hydrogen gas can form an explosive mixture. In this situation, smothering agents are recommended.

Fire fighters should wear self-contained breathing apparatus. Burning nickel metal hydride batteries can produce toxic fumes including oxides of nickel, cobalt, aluminum, lanthanum, cerium and neodymium.

6. Accidental Release Measures

Remove personnel from area until fumes dissipate. Do not breathe vapours or touch liquid with bare hands. Provide sufficient room ventilation if required.

If the skin has come into contact with the electrolyte, it should be washed thoroughly with water.

Use neoprene or natural rubber gloves and protective glasses, if handling an open or leaking battery. Battery materials should be collected in a leak-proof container and disposed of as Special Waste. in accordance with local regulations.

7. Precautions for safe Handling and Use

Storage: Store in a cool (preferable below 25°C), well ventilated area, away from moisture, sources of heat, and open flames. Elevated temperatures can result in shortened battery life. Temperatures above 70°C may result in battery leakage and rupture. Keep adequate clearance between walls and batteries. Since short circuit can cause burn, leakage and rupture hazard, keep batteries in original packaging until use and do not jumble them.

RUGGED AUTHORITY www.cord-ex.com

Page 6: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

Handling: Do not crush, pierce, short (+) and (-) battery terminals with conductive (i.e. metal) goods, which would end up into excessive heating. Do not directly heat or solder. Do not throw into fire. Do not mix batteries of different types and brands. Do not mix new and used batteries. Keep batteries in non conductive (i.e. plastic) trays. Do not disassemble, mutilate or mechanically abuse cells and batteries. In order to prevent seal or safety vent damage, never solder the batteries directly at the battery terminals.

Charging: This battery is made to be charged many times. Use only specified charger. Follow manufacturer data in respect of charge current and charge time. Note correct polarity. Improper charging can cause heat damage or even high pressure rupture.

Disposal: Dispose in accordance with all applicable federal, state and local regulations.

8. Special Protection Information

Ventilation Requirements: Not necessary under normal conditions. Room ventilation may be required in areas where there are open or leaking batteries.

Respiratory Protection: Not necessary under normal conditions. Avoid exposure to electrolyte fumes from open or leaking battery. In all fire situations use self-contained breathing apparatus.

Eye Protection: Not necessary under normal conditions. Wear safety glasses with side shields if handling an open or leaking battery.

Hand Protection: Not necessary under normal conditions. Use neoprene or natural rubber gloves if handling an open or leaking battery

9. Physical and Chemical Properties

Note: The following points are not applicable unless in case of leaking or damaged batteries with exposed internal components.

Appearance: Nickel plated steel cylindrical cell, evenually sleeved.

Odour: Odourless (unless in case of damaged product with leaking electrolyte)

Flashpoint: Not applicable

Flammability: Not applicable

Relative density: > 2 g/cm3

Specific energy: 30…90Wh/kg

Temperature range: Usage recommended between -40°C and +70°C.

10. Stability and Reactivity

Product is stable under conditions described in Section 7.

RUGGED AUTHORITY www.cord-ex.com

Page 7: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

Conditions to avoid: Heat above 70° or incinerate. Deform. Mutilate. Crush. Pierce. Disassemble. Short circuit. Expose over a long period to humid conditions.

Materials to avoid: Strong mineral acids, alkali solutions, strong oxidising materials and conductive materials.

Hazardous decomposition products: Electrolyte solution is corrosive to all human tissues and will react violently with many organic chemicals. Electrolyte solution reacts with zinc, aluminum, tin and other materials releasing flammable hydrogen gas.

11. Toxicological Information

Nickel metal hydride batteries are not hazardous waste. Under normal conditions of use, Ni-MH batteries are non-toxic. In case of can opening or destruction, the following substances can be released:

12. Ecological Information

The sealed NiMH cells as a product are not presenting ecotoxicological hazards. In case of product destruction or opening, the substances described in paragraph 11 can come in contact of the environment. The metals content in a NiMH battery are toxics for the environment.

If not recycled, it must be disposed of in accordance with all state and local regulations.

Substances Hazards

Name N° EC N° CAS N° EINIC

Symbol Effects Dust exposure limits Carcinogenicity mutagenicity protoxicity

Nickel 028-002-00-7 7440-02-0 231-111-4

Ni Xn Nocif R 40-43 R 17

Nickel-Hydroxyde 028-008-x* 12054-48-7 235-008-5

Ni(OH)² LD50/oral/rat: 1600mg/kg

VME: 1000μg/m3 Occupational

Cobalt-Hydroxyde - 21041-93-0 244-166-4

Co(OH)² LD50/oral/rat: 795mg/kg

VME: 100μg/m3 VLE: /

/

Alkaline-Hydroxdyes

019-002-00-8 1310-58-3

KOH NaOH LiOH

LD50/oral/rat: 365mg/kg

KOH VME: 2mg/m³ NaOH VME: 2mg/m³ LiOH VME: 25μg/m³

/

RUGGED AUTHORITY www.cord-ex.com

Page 8: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

13. Disposal Considerations

USA: NiMH batteries are classified by the federal government as non-hazardous waste and are safe for disposal in the normal municipal waste stream. These batteries, however, do contain recyclable materials and are accepted for recycling by the Rechargeable Battery Recycling Corporation’s (RPBC) Battery Recycling Program. Please go to the RPBC website at www.rbrc.org ( www.call2recycle.org) for additional information.

In the European Union, manufacturing, handling and disposal of batteries is regulated on the basis of the DIRECTIVE 2006/66/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 6 September 2006 on

batteries and accumulators and waste batteries and accumulators and repealing Directive 91/157/EEC. Customers find detailed information on disposal in their specific countries using the web site of the European Portable Batteries Association (http://www.epbaeurope.net/legislation_national.html)

Importers and users outside EU should consider the local laws and rules.

In order to avoid short circuit and heating, used nickel metal hydride cylindrical cells and batteries should never be stored or transported in bulk. Proper measures against short circuit are:

• Storage of batteries in their original packaging

• Coverage of the terminals

14. Transport Information

Ansmann nickel metal hydride cylindrical cells/batteries are considered to be “dry cell” batteries and are unregulated of transportation by the U.S. Department of Transportation (DOT), International Civic Aviation Administration (ICAO), International Air Transport Association (IATA), the “Accord Européen Relatif au Transport International des Merchandises Dangereuses par Route” (ADR) and the “Règlement concernant le transport international ferroviaire de marchandises Dangereuses” (RID).

IATA DGR: Special Provision A123: “Examples of such batteries are: alkali-manganese, zinc-carbon, nickelmetal hydride and nickel-cadmium batteries. Any electrical battery… having the potential of a dangerous evolution of heat must be prepared for transport as to prevent (a) a short-circuit (e.g. in the case of batteries, by the effective insulation of exposed terminals…) is forbidden from transport; and (b) accidental activation.

The words “Not restricted” and the Special Provision number must be included in the description of the substance on the Air Waybill as required by 8.2.6, when an Air Waybill is issued. EU (ADR/RID): Chapter 3.2 Table A: “Batteries, nickel-metal-hydride, UN3496, not subject to ADR” USA: 49 CFR § 172.102 Special Provisions 130 and 340: Nickel metal hydride cylindrical cells/batteries are not subject to requirements of this subchapter except for the following….”Batteries and battery-powered devices containing batteries must be prepared and packaged for transport in a manner to prevent: (1) A dangerous evolution of heat; (2) Short circuits, including but not limited to the following methods:

a) Packaging each battery or each battery-powered device when practicable, in fully enclosed inner packagings made of non-conductive material

b) Separating or packaging batteries in a manner to prevent contact with other batteries, devices or conductive materials (e.g. metal) in the packagings”…

International Maritime Organization (IMO), IMDG Code: Regulated as “Batteries, nickel-metal hydride, UN 3496”, Special Provision 963: “…nickel-metal hydride cells or batteries shall be securely packed and protected from short-circuit. They are not subject to other provisions of this Code provided that they are loaded in a cargo transport unit in a total quantity of less than 100kg gross mass. When loaded in a cargo transport unit in a total quantity of 100kg gross mass or more, they are not subject to other provisions of this Code except those of 5.4.1, 5.4.3 and column (16) of the dangerous goods list in Chapter 3.2.”

RUGGED AUTHORITY www.cord-ex.com

Page 9: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

USER MANUAL TOUGHPIX II EXPLOSION PROOF DIGITAL CAMERA

RUGGED AUTHORITY www.cord-ex.com

Page 10: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

ToughPIX II is certified ATEX/IECEx as follows:

• Ex d IIB+H2 T6 Gb / II2G Gb T6

Congratulations – You are the owner of the second generation of ToughPIX digital camera designed and certified specifically for use in hazardous (explosive) atmospheres.

CONTENTS

Getting To Know Your ToughPIX II 4

Camera Charging/Docking Station 6

Overview 7

Package Contents 7

Battery Charging 8

Getting Started• Turning the Power On/Off• Mode Selection

9

Taking Pictures• Optical Zoom• Digital Zoom• Flash• Scene• Self-timer• Delete• Image Size• Anti shake• Macro• Setup

10

Taking Videos 12

Downloading Files 13

Technical Information 14

Please ensure that the certification matches or exceeds the hazardous area characteristics that will be clearly displayed on site.

Whilst in a hazardous area, do not attempt to change batteries or download images, these tasks should only be undertaken after returning to a safe area.

! !

Page 11: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

GETTING TO KNOW YOUR TC7000

1

1

9 9

5

6

7

84

4

2

2

3

3

Focus Ring 135˚ Swivel Lens

1 3Shutter Button Flash Light

2 4Power Button Lens

1 4 7LCD Screen Mode Up/Delete

2 5 8Left/Scene Menu Button Right/Flash

3 6 9Playback Down/Self Time W/T (Zoom in/Zoom out)

RUGGED AUTHORITY

ToughPix II – Explosion Proof Digital Camera

5

Page 12: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

CAMERA CHARGING /DOCKING STATION

OVERVIEW

PACKAGE CONTENTS

1 4Data communication interface Battery recharging

compartment

2 5USB Terminal Battery release lever

3Power Supply for charging unit

1

5

4

23

The SLR style ToughPIX II incorporates a 16 Megapixel sensor with 16GB memory and High Definition video capability. Close up and wide area photography is simple with crisp and clear images using the built-in macro feature, anti-shake technology, 3x optical and 4x digital zoom.

Check the contents of your ToughPIX II. The shipping case should include the following items:

• Explosion proof digital camera

• USB Communication Wand

• Docking / Charging Station

• CorDEX CONNECT™ Software

• Removable / Rechargeable Battery

• Neck Strap

• Hard Carry Case

RUGGED AUTHORITY

ToughPix II – Explosion Proof Digital Camera

7

Page 13: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

The battery is charged using the docking station supplied (See Page 6).

• Open the battery compartment of the camera and remove the retaining plug.

• Remove the battery from the battery compartment of the camera.

• Plug in the charging unit to a mains circuit and plug the jack from the charging unit into the docking station.

• Insert the battery into the battery charging compartment on the docking station.

• The charging light on the charging unit will flash green to show that the battery in charging.

• When the battery is fully charged the charging unit light will stop flashing and will show constant green.

• Remove the battery from the charging compartment

• Insert the battery pack into the camera paying careful attention to the orientation of the pack.

• Insert the retaining plug and ensure that this is tightly secured.

Turning the Power On/Off

Use the power button on the top of the camera to turn the camera on and off. If there is insufficient battery power a red icon will appear on the display and the camera will automatically power off after a few seconds. Press the shutter button to take a photo.

Mode Selection

ToughPIX II has three operating modes, Camera Video and Playback. Camera mode is the default from Power On and pressing the MODE button will toggle between Camera and Video mode. Press the Playback button to review photos and videos.

Battery charging must only be carried out in a safe area using the docking/charging station supplied. Never open the battery compartment or attempt to download data within a hazardous environment.

!

BATTERY CHARGING GETTING STARTED

RUGGED AUTHORITY

ToughPix II – Explosion Proof Digital Camera

9

Page 14: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

Scene

Scene is selected using the left button and toggles through several setting options: Auto, Night Portrait, Night Scenery, Portrait, Scenery, Beach, Sport, High Sensitivity.

Self-timer

Self timer is selected using the down button to toggle through 4 self-timer options: 2 sec, 5 sec, 10 sec or Off.

Delete

Press the up button to delete the last photo or video captured. A “Delete This Image” confirmation message will appear in the display, use the left/right buttons to choose yes to delete the image or no to cancel the delete.

Image Size

To set the image size, press MENU and use the right/left button to select the MP icon. The image size menu will appear in the display and the up/down buttons will select the required image size.

Anti-Shake

This function prevents blurring of the photo as a result of hand shake. It is accessed through the MENU button and using the right/left button to select the Hand icon.

Macro

The macro or close-up function enables clear photos to be taken within a distance of 15cm to 45cm from the subject. Press the MENU button and use the right/left button to select the macro icon The macro menu will appear in the display and the up/down button will toggle the macro and distance function on and off.

Setup

You can adjust the many camera setup options by pressing the MENU button and using the right/left button to select the TOOL icon. The setup menu on the display enables adjustment of: Exposure, ISO, White Balance, Sharpness, Quality, Digital Zoom, Date, Beep Sound, Auto Power Off, Language, Frequency, Format, Default Setting.

Optical Zoom

You can magnify your subject up to 3 times using the optical zoom by pressing the T and W buttons to zoom in and out.

Digital Zoom

You can magnify your subject up to 4 times further using the digital zoom by pressing the T and W buttons to zoom in and out. An icon in the display will show whether you are using optical or digital zoom.

Flash

In low light conditions it is recommended to use the built-in flash. Use the flash/right button to toggle through the four flash modes:

Force flash

Auto

Red eye reduction

No flash

TAKING PICTURES

AUTO

RUGGED AUTHORITY

ToughPix II – Explosion Proof Digital Camera

11

Page 15: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

Photo and video file can only be downloaded using the docking/charging station supplied.These files may then be transferred to any PC with a USB connection.

• Connect one end of the USB cable to an available USB port on your computer

• Connect the other end of the USB cable to the USB terminal on the docking station

• Remove the battery pack from the camera (see page 8) and gently place the camera onto the Data Communication Interface on the docking station

Windows Users

• From the Windows desktop, double click on My Computer.

• Look for a new ‘removable disk’ icon. This ‘removable disk’ is actually the memory (or memory card) in your camera. (Typically, the camera will be assigned drive letter ‘e’ or higher)

• Double click on the removable disk and locate the DCIM folder.

• Double click on the DCIM folder to open it to find more folders. Your recorded images and video clips will be inside these folders.

• Copy & Paste or Drag-N-Drop image and video files to a folder on your computer.

Mac Users

• Double-click the ‘untitled’ or ‘unlabeled’ disk drive icon on your desktop.

• iPhoto may automatically launch

DOWNLOADING FILES

Press the MODE button to select video mode Press and release the shutter button

to start recording. The elapsed time will appear on the top right of the display and the recording icon will flash. Press the shutter button again to stop the recording and save the file in AVI format. Use the playback mode

to view your recording.

TAKING VIDEOS

RUGGED AUTHORITY

ToughPix II – Explosion Proof Digital Camera

13

Page 16: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

Certificate Information

ATEX / IECEx Certificate No TRAC13ATEX0046X / IECEx TRC 13.0016x

ATEX / IECEx Certificate Type Ex d IIB+H2 T6 Gb / II2G Gb T6

Ambient temperature Tamb -20C to +50C

General Information

Image download High Speed USB (safe area only)

Image storage 16GB

Standard image capture resolution 16 Megapixel

Zoom 3 x optical, 4 x digital zoom

Screen size 2.7 inches

Additional features Anti shake, auto focus, macro, face recognition

Tripod mount ¼ inch 20 TPI

Detailed information

Body material Anodised aluminium with anti-static over mould

Lens & LCD material Armoured Glass

Weight 900g

IP 54

Electrical information

Battery type Removable & Rechargeable

Capacity 1100mAh

Cell type NiMH

RUGGED AUTHORITY

ToughPix II – Explosion Proof Digital Camera

15

Page 17: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

Copyright © 2014, CorDEX Instruments Limited.

All other brand and product names are trademarks of CorDEX Instruments Limited. Ref.ID 2341-MAN, Rev.C

Page 18: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

INSTRUCTIONS FOR SAFE OPERATIONS TOUGHPIX II EXPLOSION PROOF DIGITAL CAMERA

RUGGED AUTHORITY www.cord-ex.com

Page 19: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

CONTENTS READ THIS FIRST

Read This FirstLiabilityTrademark Information Product Information

3333

Instructions for Safe Use 4

Labelling 5

Operational Cautions 6

CertificationEC Declaration of ConformityATEX / IECEx Certificate

789

The ToughPIX II 24xx range of flameproof digital cameras are suitable for use in hazardous areas (Ex zones: potentially explosive environments).

Read and understand all Warnings and Cautions before using this product.

Liability

The technical specification of the camera complies with relevant European Ex standards (EN 60079-0 and EN60079-1).

The user is solely responsible for ensuring the equipment is suitable for the intended purpose and environments.

CorDEX Instruments will not be liable for any injury or damage resulting from unauthorized adjustments to, or dismantling of, the camera or for use with inappropriate applications or environments.

Trademark Information

Microsoft® and Windows® are U.S. registered trademarks of Microsoft Corporation. Pentium® is a registered trademark of Intel Corporation.

Macintosh is a trademark of Apple Computer, Inc. SD™ is a trademark.

Other names and products may be trademarks or registered trademarks of their respective owners.

Product Information

Product design and specifications are subject to change without notice. This includes primary specifications, software, software drivers, and user’s manual. The User Manual is a general reference guide for the product.

The manufacturer assumes no liability for any errors or discrepancies in the user manual.

RUGGED AUTHORITY

ToughPIX II – Explosion Proof Digital Camera

3

Page 20: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

Focus Ring 135˚ Swivel Lens

LABELLINGINSTRUCTIONS FOR SAFE USE

CorDEX Instruments Ltd. 1 Owens Rd, Middlesbrough, TS6 6HE, UK

TP2410 – Explosionproof Digital Camera

Ex d IIB+H2 T6 GbTamb -20°C to +50°C ATEX –TRAC13ATEX0046X IECEx :IECEx TRC 13.0016X Serial Number- XXXX-XX-XXXX Year of Construction- YYYY

Powered by – Refer to Manual

II 2 G

XXXX

DO NOT OPEN WHEN EXPLOSIVE ATMOSPHERE PRESENT

The conditions referenced in this section relate specifically to hazardous area applications and must be followed.

In accordance with clause 5.1 of EN 60079-1, the critical dimensions of the flamepaths are:

• Contact the manufacturer for information on the dimensions of the flameproof joint

• The apparatus must only be used in areas where there is low risk of impac

• Do not charge battery pack in the hazardous are

• The battery must be removed from the camera and charged in the CorDEX Instruments ToughPIX II charging bay part number CDX-2400-XXX. Using a different charging device will void the certification.

• The ToughPIX II 2410 Series digital camera incorporates a protected battery system with a non-replaceable fuse. This fuse is only to be replaced by CorDEX Instruments or a CorDEX Instruments Approved Repair Facility. Failure to do so will void the certification.

• Ensure that the ToughPIX II 2410 Series digital camera battery pack is secured using the plug provided. If the plug is lost, only replace with a plug of the correct size and type. If in doubt, contact your nearest CorDEX Instruments representative.

• The ToughPIX II 2410 Series digital camera is manufactured from aluminium alloy; and must contain less than 7% magnesium by weight and incorporates toughened glass windows. This should be taken into account when considering the end use application.

• TheToughPIX II 2410 Series digital camera cannot be maintained in the field andmust be returned to the manufacturer should repair or maintenance be required.

• USB communications with the ToughPIX II 2410 Series digital camera must only occur within the non-hazardous area

• When replacing the battery pack, the screw must be re-tightened to a torque of 1.5-4Nm and the cover cap replaced.

• Only CorDEX battery pack CDX2400-011 shall be use

Flamepath Maximum Gap (mm)

Minimum L (mm)

Rearcarriage/front carriage

0.04 6.5

Flash Window/frontcarriage

0.1 13.8

LCDWindow/frontcarriage

0.1 13.8

Lens window/frontcarriage

0.1 13.8

Operatingrod/rear and

0.1 10.5

RUGGED AUTHORITY

ToughPIX II – Explosion Proof Digital Camera

5

Page 21: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

CERTIFICATION

Model TP2410

ATEX Certificate No. TRAC13ATEX0046X

ATEX Coding XXXX

IIB+H2 T6 Gb Tamb -20°C to +50°C

Ambient Temperature -20° to +50°C

Power Supply ToughPIX II 2410 Series Removable Rechargeable Battery Pack, part number CDX-2410-011

These will need replacing with new branded ones

OPERATIONAL CAUTIONS

The cautions contained in this section do not relate specifically to safe use in hazardous area applications but should be followed to help prevent damage to the device or personnel.

• Keep out of reach of children

• The TP2410 is a precision instruction. Do not drop it, strike it or use excessive force when handling

Maintenance

For safety critical maintenance, please refer to EN60079-17

RUGGED AUTHORITY

ToughPIX II – Explosion Proof Digital Camera

7

Page 22: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

EC DECLARATION OF CONFORMITY

Better:Better_Work:CorDEX:03_CorDEX_Products:CorDEX_Products_ToughPIXII:CorDEX_Products_ToughPIXII_ECDeclaration:EC Declaration of Conformity (TP2410XP)Rev A.docx

CorDEX Instruments Ltd Unit 1, Owens Road Skippers Lane Industrial Estate, MIDDLESBROUGH, TS6 6HE

Declaration No. SO/11 Rev 3

EC Declaration of Conformity in accordance with EEC ATEX Directive 94/9/EC

We,

CorDEX Instruments Ltd.

Hereby declare that the products described below Product: Explosion-proof digital camera Model: TP2410XP are in conformity with the essential health and safety requirements of Council Directive 94/9/EC relating to equipment intended for use in potentially explosive atmospheres (ATEX Directive) Ex II 2 G, Ex d IIB+H2 T6 Gb(Tamb -20°C to +50°C) equipment, by the application of the following Standards:-

BS EN 60079-0:2012 Explosive atmospheres - Equipment. General requirements

BS EN 60079-1:2007 Explosive atmospheres. Equipment protection by flameproof enclosures "d"

as certified by Notified Body Number 0891 TRaC Global Ltd, UK by EC-Type Examination Certificate: TRAC13ATEX0046X and IECEx Certificate: IECEx TRC 13.0016X and are subject to the procedure set out in Annex VII of Directive 94/9/EC and these procedures are in conformity with the requirements of EN 80079-34 under the supervision of Notified Body Number 0518, SIRA Certification Service, Rake Lane, Eccleston, Chester, CH4 9JN, England. It is ensured through internal measures that the products conform at all times to the requirements of the current EEC Directives and relevant standards.

Signature: ________________________ Authorised Person

Position: Director on behalf of CorDEX Instruments Ltd

Date: 07/10/2014

Product Serial number

IECEx Certificate?

RUGGED AUTHORITY

ToughPIX II – Explosion Proof Digital Camera

9

Page 23: Data Sheet Material Safety - 247able.com · Data Sheet Material Safety. MATERIAL SAFETY DATA SHEET ANSMANN ... Unit 3117-18, 31/F; Tower 1; Millenium City 1; No. 388 Kwun Tong Road;

Copyright © 2014, CorDEX Instruments Limited.

All other brand and product names are trademarks of CorDEX Instruments Limited. Document Reference: TP2400SOM Rev. A