dark matter search

18
DARK MATTER DARK MATTER SEARCH SEARCH arter Hall, University of Maryland arter Hall, University of Maryland

Upload: koleyna-nelson

Post on 31-Dec-2015

32 views

Category:

Documents


0 download

DESCRIPTION

DARK MATTER SEARCH. Carter Hall, University of Maryland. Direct detection of WIMP dark matter. ~ 3 00 proton masses per liter of space. If M WIMP ~ 100 GeV, then 3 WIMP/liter. Typical orbital velocity ~ 230 km/sec, or 0.1% speed of light. Coherent scaler interactions: ~ A 2. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: DARK MATTER SEARCH

DARK MATTER DARK MATTER SEARCHSEARCH

Carter Hall, University of MarylandCarter Hall, University of Maryland

Page 2: DARK MATTER SEARCH

Direct detection of WIMP dark matter

00 proton massesper liter of space.

If MWIMP ~ 100 GeV,then 3 WIMP/liter.

Typical orbital velocity~ 230 km/sec,

or 0.1% speed of light.

Coherent scaler interactions:

~ A2

Rate < 1 event / kg / 100 days, or much, much lower

Page 3: DARK MATTER SEARCH
Page 4: DARK MATTER SEARCH

It’s not difficult to shield at 10 keV

typical WIMP recoil energies

Gamma interaction cross section

Only MeV ’s can penetrate,but only keV ’s can

fake a WIMP

Page 5: DARK MATTER SEARCH

Self-shielding of liquid xenon is extremely powerful

Fiducial volume cut rejects most backgrounds

Page 6: DARK MATTER SEARCH

Sensitivity improves quickly as target mass increases!Self-shielding effect

Page 7: DARK MATTER SEARCH

Particle ID: nuclear recoil discrimination

Ionization-to-scintillation ratio allows discrimination between common radioactivity and WIMP events.

Background rejection factor of ~180

Page 8: DARK MATTER SEARCH

The Hunters HutThe Hunters Hut Homestake (SD)Homestake (SD)

Page 9: DARK MATTER SEARCH

Davis Cavern @ Homestake, 9/21/09

Page 10: DARK MATTER SEARCH
Page 11: DARK MATTER SEARCH

Gaitskell - Brown University / LUX

LUX Detector - Overview

Titanium Vessels

Dodecagonal field cage+ PTFE reflector panels

PMT holding copper plates

Counterweight

Feed-throughs for cables / pipesLN bath column

Radiation shield

49 cm

59 cm

Cathode grid

Anode grid

Page 12: DARK MATTER SEARCH

LUX 350 kg detector under construction

Page 13: DARK MATTER SEARCH

Test fit of detector inside the titanium cryostat

Assembly & commissioning in a new laboratory on the surface at Homestake

Page 14: DARK MATTER SEARCH

Xenon Purity measured in a 60 kg test run

• ~9 hr time constant for purification

• > 2 m electron drift length achieved(> 1000 us) with 60kg target

•Errors dominated by use of 5 cm test cell drift within large cryostat

0.2 tonnes circulation per day

Page 15: DARK MATTER SEARCH

Heat Exchanger Operates >96% EfficientDemonstrated - 18 W required to circulate 0.4 tonnes of Xe a

dayEvaporate Liquid > Gas / Purification -> Re-condense Liquid

Page 16: DARK MATTER SEARCH

LUX dark matter sensitivity

Status: LUX is being now being assembled on the surface at Homestake.Expect to move underground in December 2010.

Page 17: DARK MATTER SEARCH
Page 18: DARK MATTER SEARCH

Collaboration meeting @ Homestake mine, March 1, 2009Collaboration meeting @ Homestake mine, March 1, 2009