DAM BREACH / HAZARD CLASS ANALYSIS Warren Johnson, P.E. Civil Engineer Frederick, Maryland

Upload: others

Post on 20-Jan-2020

14 views

Category:

Documents


0 download

TRANSCRIPT

DAM BREACH / HAZARD CLASS ANALYSIS

Warren Johnson, P.E.Civil Engineer

Frederick, Maryland

Dam Classification

• Structure Hazard Classification -Documentation of the classification of dams is required.

• Documentation is to include but is not limited to location and description of dam, configuration of the valley, description of existing development (houses, utilities, highways, railroads, farm or commercial buildings, and other pertinent improvements), potential for future development, and recommended classification.

Dam Classification Documentation

• Qmax discharge.• Description of Dam.• Description of all roads, structures and utilities

down stream of pond.• Map showing pond, downstream structures, cross

section locations and proposed breach wave.• All appropriate, routing, computations and

supporting cross sections.• Conclusion.

Dam Classification• The class (“a”, “b”, and “c”) as contained in

this document is related to the potential hazard to life and property that might result from a sudden major breach of the earth embankment.

The classification of a dam is the responsibility of the designer, and subject to review and concurrence of the approving authority.

Dam Classification• The classification of a dam is determined

only by the potential hazard from failure, not by the criteria. Classification factors in the NRCS - National Engineering Manual, as supplemented, are given below:

• Class “a” - Structures located in rural, agricultural or urban areas dedicated to remain in flood tolerant usage where failure may damage non-inhabited buildings, agricultural land, floodplains or county roads.

Dam Classification

• Class “b” - Structures located in rural, agricultural, or urban areas where failure may damage isolated homes, main highways or minor railroads or cause interruption of use or service of relatively important public utilities.

• Class “c” - Structures located where failure may cause loss of life or serious damage to homes, industrial and commercial buildings, important public utilities, main highways, or railroads.

Dam Breach

• NRCS uses a Sunny-day breach approach.– Increased likelihood of people down stream.– Conservative discharge on small structures.

Dam Failure Methods for Small Dams

• Use Breach Equation to determine Breach Flows

• Determine Downstream Flood Depths– Simple approach, Manning’s formula with

downstream cross sections – HECRAS Model

• Stop Danger Reach when hazard no longer exists

Dam Breach• The minimum peak discharge of the breach

hydrograph, regardless of the techniques used to analyze the downstream inundation area, is as follows:

• Qmax = 3.2 Hw2.5 where, Qmax = the peak breach

discharge, cfs.• Hw = depth of water at the dam at the time of

failure, feet. This is measured to the crest of the emergency spillway or to design high water, if no emergency spillway exists. Use “nonstorm”conditions downstream of the dam.

Dam Breach

Emergency Spillway or DHW Elevation

Hw

Existing Ground

Dam Breach

Hw

Emergency Spillway or DHW Elevation

Excavate for Barrel

Existing Ground

Dam Breach

Hw

Emergency Spillway or DHW Elevation

Existing Ground

Dam BreachEmergency Spillway or DHW Elevation

Hw

Existing Ground

Dam Breach

Where breach analysis has indicated that only overtopping of downstream roads will occur, the

following guidelines will be used:

Class Depth of Flow(d) ft.

“a” d < 1.5

“b” & “c” d > 1.5

importance of the roadway shall be considered when making a classification.

Flood Danger for Cars

0.00

0.50

1.00

1.50

2.00

2.50

3.00

3.50

0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0

Velocity [fps]

Floo

d D

epth

[ft

]

Low Danger Judgement Zone High Danger

Low Danger Zone

High Danger Zone

Judgement Zone

Dam Breach

• Breach flow against a house. Class “b” -Structures located in rural, agricultural, or urban areas where failure may damageisolated homes,…….

• Use Flood Danger for Houses graphics for determination of hazard.

• If home has basement and breach water may enter basement via window well or door, this may be considered damage.

Flood Danger for Houses

0.00

1.00

2.00

3.00

4.00

5.00

6.00

7.00

0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 25.0

Velocity [fps]

Floo

d D

epth

[ft

]

Low Danger Judgement Zone High Danger

Low Danger Zone

High Danger Zone

Judgement Zone

Source: USBR Hazard Charts, 1988

Flood Danger for Adults

0.00

0.50

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

5.00

0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00

Velocity [fps]

Floo

d D

epth

[ft

]

Low Judgement High

Low Danger Zone

High Danger Zone

Judgement Zone

Source: USBR Hazard Charts, 1988

Dam Breach – How far downstream should the analysis be taken

• To a point where there are no structures present downstream of the pond.

• The breach wave enters a flood prone area where no structures are present.

• The total volume of proposed breach is stored within the downstream valley, another storage structure or by a roadway fill.

Determining Danger Reach Length

• Height of dam = 10 feet• Volume of storage = 8 acre feet• Average valley width (usually at the 100 year

flood plain) = 400 feet

Wid

th o

f Val

ley

in F

eet (

100

year

floo

d pl

ain)

H = Height of Dam

Length of Reach per Ac. – Ft. of Storage for Depth (Lower) = 1 foot

8 ac. ft. x 160 length of reach per ac. ft. = 1280 ft.

160

Example Dam Breach Analysis

Breach Wave Map

SWM Facility

Proposed Breach

Houses / Road

Dam Classification

• Other things to look out for.

Dam Classification

• Ponds exempt from the requirements of the Soil Conservation District Small Pond Approval Letter (i.e., excavated ponds) must be classified prior to exemption. The exemption must be reviewed and have concurrence of the approving authority.

Dam Breach

3’

Excavated PondClass “a” Structure?

TABLE 1 - HYDROLOGIC CRITERIA FOR PONDS

Spillway Capacity5

Principal2 Emergency3, 4 Freeboard6

Rural Urban Rural Urban Rural & Urban

“c” & “b”

Any Any Any Any TR 60 TR 60 TR 60 TR 60 TR 60

“a” 3,000 ormore

Any Any Any TR 60 TR 60 TR 60 TR 60 TR 60

320 >20 - 35 >12 25 YR TR 60 100 YR

100 YR

Less and <20 >12 10 YR 25 YR 100 YR

100 YR

Larger <15 <12 5 YR 10 YR 50 YR 100 YR

100 >20 - 35 >12 10 YR TR 60 100 YR

100 YR

2.0’ above E.S.Design Storm

“a” than to <20 >12 5 YR 10 YR 50 YR 100 YR

1.0’ above E.S.Design Storm

320 <15 <12 2 YR 5 YR 25 YR 100 YR

1.0’ above E.S.Design Storm

Less >20 - 35 >12 5 YR TR 60 50 YR 100 YR

3,000 Than <20 >12 2 YR 5 YR 25 YR 100 YR

100 <15 <12 10% of 25 YR Peak

5 YR 25 YR 100 YR

1.0’ above E.S.Design Storm

Structure

Class

StorageHeight

Product1 Watershe

dArea

(Acres)

Height ToEmergenc

ySpwy Crest(Feet)

Normal

Surface

Area(Acres)

2.0’ above E.S.Design Storm

ThereforeClass “a”

Where to Breach

Breach Here

Breach Here

Dam Breach – Weir length at road

Weir Length At Road

Dam Breach – Weir length at road

2HAverage Breach Width

41

Width At Road

Dam Breach – Breach width downstream

2HAverage Breach Width

21

Width At House

Dams In Series

Dams in Series - Considerations

• Effects of the proposed breach, from the upstream pond, on the downstream pond.

• Potential breach of downstream pond.• Effects of breach of from both ponds.

Potential for Downstream Development

• Zoning• Land use Plans• Pathway for breach