curvas caracteristicas de las bombas durco mark iii

60
Durco Mark 2 & 3 Self-Priming Pumps 60 & 50 Cycle Performance Curves For Group II & III Pumps Bulletin P-12-102g

Upload: fagb1978

Post on 14-Apr-2015

454 views

Category:

Documents


23 download

TRANSCRIPT

Page 1: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

Durco Mark 2 & 3Self-Priming Pumps

60&50 CyclePerformanceCurvesFor Group II & III Pumps

Bulletin P-12-102g

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 1

Page 2: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 2

Page 3: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

3

0 80 160 240 320 400 480

20 40 60 80 100

0

0

0

0

0

0

640

560

480

400

320

240

160

80

0

FLOW - 3500 rpm (60Hz) m3/h

FLOW - 3500 rpm (60Hz) US gpm

TDH

350

0 rp

m (6

0Hz)

m

TDH

350

0 rp

m (6

0Hz)

ft

Mark II & Mark IIICOMPOSITE PERFORMANCEREVERSE VANE IMPELLER3500 (rpm)CURVE NO. ____________MARCH 2000

1

2

3

1

2

3

1J1-1/2X1US-6

1K1-1/2X1-1/2US-82

2K2X1-1/2US-10A

2K3X2US-104

4

2540A

PUMP SPEED CURVE # PAGEComposite 3500 2540A 3

Curves 1750 2541A 41150 2542A 4

1J1-1/2X1US-6 3500 MII 7060V 51750 MII 7062V 6

1K1-1/2X1-1/2US-82 3500 MIII 7260 71750 MIII 7262 8

2K2X1-1/2US-10A 3500 MIII 8060V 91750 MIII 8062V 101150 MIII 8064V 11

2K3X2US-10 3500 MIII 7860V 121750 MIII 7862V 131150 MIII 7864V 14

2K3X2US-13 1750 MIII 7460V 151150 MIII 7462V 16

2K4X3US-10H 1750 MIII 7660V 171150 MIII 7662V 18

2K4X3US-13 1750 MIII 7560V 191150 MIII 7562V 20

2K6X4US-13A 1750 MIII 8160V 211150 MIII 8162V 22

PUMP SPEED CURVE # PAGEComposite 2900 2538A 23

Curves 1450 2539A 231J1-1/2X1US-6 2900 MII 7061V 24

1K1-1/2-1/2US-82 2900 MIII 7261 251450 MIII 7263 26

2K2X1-1/2US-10A 2900 MIII 8061V 271450 MIII 8063V 28

2K3X2US-10 2900 MIII 7861V 291450 MIII 7863V 30

2K3X2US-13 1450 MIII 7461V 312K4X3US-10H 1450 MIII 7661V 322K4X3US-13 1450 MIII 7561V 33

2K6X4US-13A 1450 MIII 8161V 34

Index-60 Cycle Reverse Vane Curves Index-50 Cycle Reverse Vane Curves

See page 35 for Index-60 & 50 Cycle Open Vane Curves.

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 3

Page 4: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

4

0 200 400 800 1200 1600 2000

20 40 60 80 100 140 180 220 260 300 340 380 420

90

80

70

60

50

40

30

20

10

0

320

280

240

200

160

120

80

40

0

FLOW - 1750 rpm (60Hz) m3/h

FLOW - 1750 rpm (60Hz) US gpm

TDH

175

0 rp

m (6

0Hz)

m

TDH

175

0 rp

m (6

0Hz)

ft

Mark II & Mark IIICOMPOSITE PERFORMANCEREVERSE VANE IMPELLER1750 (rpm)CURVE NO. ____________MARCH 2000

1

3

4

5

6

7

6 7

1

2

3

4

5

SCAL

ECH

ANGE

2

8

8

1J1-1/2X1US-6

1K1-1/2X1-1/2US-82

2K2X1-1/2US-10A

2K3X2US-10

2K4X3US-10H

2K3X2US-13

2K4X3US-13

2K6X4US-13A

2541A

0 200 400 600 800 1000 1200

20 40 60 80 100 120 140 160 180 200 220 240 260

20

15

10

5

0

80

70

60

50

40

30

20

10

0

FLOW - 1150 rpm (60Hz) m3/h

FLOW - 1150 rpm (60Hz) US gpm

TDH

115

0 rp

m (6

0Hz)

m

TDH

115

0 rp

m (6

0Hz)

ft

Mark IIICOMPOSITE PERFORMANCEREVERSE VANE IMPELLER1150 (rpm)CURVE NO. ____________MARCH 2000

1

2

3

4

5

6

1

2

3

4

5 6

2542A

2K2X1-1/2US-10A

2K3X2US-10

2K3X2US-13

2K4X3US-10H

2K4X3US-13

2K6X4US-13A

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 4

Page 5: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

5

0 20 40 60 80 100

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

1J1-1/2X1US-63500 (rpm)7060V

2.77 in2

3/8 inREVERSE VANESTD-N/A

DURCO MARK II

SPEED

CURVE NO.

5 10 15 20 25

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)3

2

1

0

(m)10

5

00 40 80 120

0 10 20

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

5in6in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 1.5inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

40

30

20

10

4

3

2

1

140

100

60

20 8

6

4

2

0

4in

4 in Ø

4-1/2 in Ø

6 in Ø

5-1/2 in Ø

5 in Ø

40

1014

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-22

US (gpm)

(m3/h)

20 3045

48

48

3 4 6

EFF %

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 5

Page 6: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

6

0 12 24 36 48 60

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

1J1-1/2X1US-61750 (rpm)7062V

2.77 in2

3/8 inREVERSE VANESTD-N/A

DURCO Mark II

SPEED

CURVE NO.

5 10 15

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft).6

.4

.2

0

(m)2

1

00 20 40 60

0 5 10

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

6in

0 120 240 360PRIMING TIME SECONDS

VOLUME OF 1.5inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

12

8

4

.6

.4

.2

40

30

20

10

0

10

.8

.6

.4

.2

0

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-22

US (gpm)

(m3/h)

40

20

TDH

EFF %

EFF %

0

(hp)

(ft)

4

2

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 6

Page 7: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 50 100 150 200 250

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

1K1-1/2X1-1/2US-823500 (rpm)7260

2.62 in2

5/16 inREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

10 20 30 40 50 60

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft) 30

20

10

0

(m)

80

40

00 100 200 300

0 20 40

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

8 3/16in

5in

6in

0 20 40 60 80PRIMING TIME SECONDS

VOLUME OF 1.5inSUCT. PIPE EQUALSSTATIC LIFT + 3ft

80

70

60

50

40

30

20

10

15

10

5

300

250

200

150

100

50

0

30

20

10

0

7in

8-3/16 in Ø

8 in Ø

7-1/2 in Ø

7 in Ø

6-1/2 in Ø

6 in Ø

5-1/2 in Ø

5 in Ø

40

46

1216

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft) P(kW)

(m3/h)

US (gpm)

Y-M-D91-01-22

US (gpm)

(m3/h)

30

404

6 8

EFF %

7

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 7

Page 8: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 25 50 75 100 125

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

1K1-1/2X1-1/2US-821750 (rpm)7262

3.1 in2

11/32 inREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

5 10 15 20 25 30

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft) 6

4

2

0

(m)

16

8

00 50 100 150

0 10 20 30

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

8 3/16in

6in

0 30 60 90PRIMING TIME SECONDS

VOLUME OF 1.5inSUCT. PIPE EQUALSSTATIC LIFT + 3ft

25

20

15

10

5

2

1

100

75

50

25

0

3

2

1

0

7in

8-3/16 in Ø

7-1/2 in Ø

7 in Ø

6-1/2 in Ø

6 in Ø

4042

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D91-01-23

US (gpm)

(m3/h)

30

4042

12

46

8

EFF %

8

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 8

Page 9: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

9

0 50 100 150 200 250

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K2X1-1/2US-10A3500 (rpm)8060V

3.51 in2

13/32 inREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

10 20 30 40 50

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

10

5

0

(m)40

20

00 100 200 300

0 20 40 60

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

8in 5in6in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 2inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

120

100

80

60

40

20

30

24

18

12

6

450

350

250

150

50

0

45

30

15

0

10in&9in 7in

10 in Ø

9-1/2 in Ø

9 in Ø

8-1/2 in Ø

8 in Ø

7-1/2 in Ø

7 in Ø

6-1/2 in Ø

6 in Ø

5-1/2 in Ø

5 in Ø

35

40

42

10

14

18

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-22

US (gpm)

(m3/h)

2030

22

2 4 6

EFF %

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 9

Page 10: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 20 40 60 80 100

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K2X1-1/2US-10A1750 (rpm)8062V

3.51 in2

13/32 inREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

5 10 15 20 25

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)3

2

1

0

(m)10

5

00 50 100 150

0 10 20 30

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

8in10in 9in

0 100 200 300PRIMING TIME SECONDS

VOLUME OF 2inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

30

20

10

4

3

2

1

110

90

70

50

30 6

4.5

3

1.5

0

7in

10 in Ø

9-1/2 in Ø

9 in Ø

8-1/2 in Ø

8 in Ø

7-1/2 in Ø

7 in Ø

35

40

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)P

(kW)

(m3/h)

US (gpm)

Y-M-D82-01-25

US (gpm)

(m3/h)

20

30

38

34

6

5

EFF %

10

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 10

Page 11: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 20 40 60 80 100

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K2X1-1/2US-10A1150 (rpm)8064V

3.51 in2

13/32 inREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

4 8 12 16 20

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

1

0

(m)

4

3

20 40 80 120

0 10 20

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

9in

10in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 2inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

14

12

10

8

6

1.2

.9

.6

.3

50

40

30

20

1.5

1.0

.5

0

10 in Ø

9-1/2 in Ø

9 in Ø35

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-25

US (gpm)

(m3/h)

2030

381

1.52

2.5

EFF %

11

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 11

Page 12: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

12

0 100 200 300 400 500

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

3K3X2US-103500 (rpm)7860V

3.51 in2

13/32 inREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

20 40 60 80 100

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

10

5

0

(m)40

20

00 200 400 600

0 50 100

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

8in10in 9in

0 30 60 90PRIMING TIME SECONDS

VOLUME OF 3inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

120

100

80

60

40

20

40

30

20

10

400

300

200

100

60

40

20

0

7in

10 in Ø

9-1/2 in Ø

9 in Ø

8-1/2 in Ø

8 in Ø

7-1/2 in Ø

7 in Ø

40

10

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-25

US (gpm)

(m3/h)

3050

55

2220

55

4 6 8

EFF %

1216

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 12

Page 13: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

13

9

0 80 160 240 320 400

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K3X2US-101750 (rpm)7862V

7.51 in2

19/32 inREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

20 40 60 80 100

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

2

1

0

(m)8

4

00 100 200 300

0 20 40 60

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

8in9in10in

0 100 200 300PRIMING TIME SECONDS

VOLUME OF 3inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

24

16

8

6

4

2

100

80

60

40

20

8

4

0

7in

10 in Ø

9-1/2 in Ø

9 in Ø

8-1/2 in Ø

8 in Ø

7-1/2 in Ø

7 in Ø

40

10

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-26

US (gpm)

(m3/h)

30

50

50

12

34

6

EFF %

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 13

Page 14: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

14

0 50 100 150 200 250

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K3X2US-101150 (rpm)7864V

7.51 in2

19/32 inREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

10 20 30 40 50

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

1

0

(m)4

2

00 100 200 300

0 20 40 60

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

9in

10in

0 50 100 150PRIMING TIME SECONDS

VOLUME OF 3inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

12

10

8

6

2

1

40

35

30

25

20

15

3

2

1

0

10 in Ø

9-1/2 in Ø

9 in Ø

40

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-26

US (gpm)

(m3/h)

30

50

53

40

50

54

1

2

3

46

.5

EFF %53

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 14

Page 15: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

15

0 100 200 300 400 500

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K3X2US-131750 (rpm)7460V

7.51 in2

13/32 inREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

20 40 60 80 100 120

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)3

2

1

(m)12

7

20 200 400 600

0 50 100

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

12in 9in10in

0 40 80 120PRIMING TIME SECONDS

VOLUME OF 3inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

50

40

30

20

10

20

16

12

8

4

180

140

100

60

20

28

24

32

24

16

8

0

13in11in

10 in Ø

9-1/2 in Ø

9 in Ø

13 in Ø

12 -1/2 in Ø

12 in Ø

11 - 1/2 in Ø

11 in Ø

40

10 14

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-26

US (gpm)

(m3/h)

20 30

4548

49

40

45

48

1

18

12

2 22

26

46

8

EFF %

10-1/2 in Ø

50

52

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 15

Page 16: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 80 160 240 320 400

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K3X2US-131150 (rpm)7462V

7.51 in2

13/32 inREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

20 40 60 80 100

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

1

0

(m)4

2

00 100 200 300

0 50 100 150

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

13in

10in

11in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 3inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

20

15

10

5

5

4

3

2

1

70

50

30

10 8

6

4

2

0

12in

10 in Ø

10-1/2 in Ø

13 in Ø

12-1/2 in Ø

11 in Ø

11-1/2 in Ø

12 in Ø

10 14

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-27

US (gpm)

(m3/h)

1.52

34

5

12

8

EFF %

3040

45

49

50

45

40

16

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 16

Page 17: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

17

1

0 200 400 600 800 1000

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K4X3US-10H1750 (rpm)7660V

13.2 in2

25/32 inREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

50 100 150 200 250

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

2

1

0

(m)8

4

00 200 400 600

0 50 100

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

8in

9in10in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 4inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

30

20

10

12

8

4

100

80

60

40

20 20

15

10

5

0

7in

10 in Ø

9-1/2 in Ø

9 in Ø

8-1/2 in Ø

8 in Ø

7-1/2 in Ø

7 in Ø

60

64

64

10

14

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P (kW)

(m3/h)

US (gpm)

Y-M-D82-01-27

US (gpm)

(m3/h)

30 50

60

2 3 4 6

12

16

8

EFF %

16

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 17

Page 18: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 100 200 300 400 500

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K4X3US-10H1150 (rpm)7662V

13.2 in2

25/32 inREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

20 40 60 80 100 120

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

1

0

(m)4

2

00 200 400 600

0 50 100

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

9in

10in

0 50 100 150PRIMING TIME SECONDS

VOLUME OF 4 inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

15

10

5

4

3

2

1

50

40

30

20

10

0 6

4

2

0

10 in Ø

9-1/2 in Ø

9 in Ø

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-27

US (gpm)

(m3/h)

30 50

60

6064

64

1 23

4

65

EFF %

18

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 18

Page 19: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 200 400 600 800 1000

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K4X3US-131750 (rpm)7560V

13.25 in2

11/16 inREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

50 100 150 200 250

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)3

2

1

0

(m)10

5

00 400 800 1200

0 100 200

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

12in

9in

10in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 4inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

50

40

30

20

10

28

24

20

16

12

8

4

180

140

100

60

0 40

30

20

10

0

13in 11in

10 in Ø

9-1/2 in Ø

9 in Ø

13 in Ø

12-1/2 in Ø

12 in Ø

11-1/2 in Ø

11 in Ø

10-1/2 in Ø

20

40

12

24

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-28

US (gpm)

(m3/h)

60

3050

16

55

60

50

55

24

68

EFF %

19

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 19

Page 20: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 100 200 300 400 500

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K4X3US-131150 (rpm)7562V

13.25 in2

11/16 inREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

20 40 60 80 100 120

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

1

.5

0

(m)4

2

00 200 400 600

0 50 100

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

12in

13in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 4inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

24

20

16

12

8

6

4

2

80

70

60

50

40

30

12

8

4

0

13 in Ø

12-1/2 in Ø

12 in Ø

40

11

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-28

US (gpm)

(m3/h)

60

3050

55

60

55

12

3

4

6

5

7

9

EFF %

20

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 20

Page 21: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

21

0 400 800 1200 1600 0

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K6X4US-13A1750 (rpm)8160V

29 in2

1-1/32 inREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

100 200 300 400 500

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

2

0

(m)10

0

0 500 1000 1500

0 100 200 300

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

12in

9in

10in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 6inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

50

40

30

20

10

50

40

30

20

10

180

140

100

60

20 80

60

40

20

0

13in 11in

10 in Ø

9-1/2 in Ø

9 in Ø

13 in Ø

12-1/2 in Ø

12 in Ø

11-1/2 in Ø

11 in Ø

10-1/2 in Ø

69

12

10

14

18

65

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-28

US (gpm)

(m3/h)

60

68

50

16

1

46

8

EFF %

-2

-10

1 VIBRATION AND NOISE EXCEEDS SPECIFIED LIMITS.

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 21

Page 22: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

22

0 200 400 600 800 1000

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K6X4US-13A1150 (rpm)8162V

29 in2

1-1/32 inREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

50 100 150 200 250

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

1

0

(m)4

0

-40 400 800 120

0 100 200

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

12in

13in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 6inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

20

15

10

16

12

8

4

80

70

60

50

40

20

10

0

13 in Ø

12-1/2 in Ø

12 in Ø 69

65

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-29

US (gpm)

(m3/h)

60

68

50

23

4

6

5

EFF %

-1

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 22

Page 23: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 20 40 60 80 100 120

100 200 300 400 500

500

450

400

350

300

250

200

150

100

50

0

160

140

120

100

80

60

40

20

0

FLOW - 2900 rpm (50Hz) m3/h

FLOW - 2900 rpm (50Hz) US gpm

TDH

290

0 rp

m (5

0Hz)

m

TDH

290

0 rp

m (5

0Hz)

ft

Mark II & Mark IIICOMPOSITE PERFORMANCEREVERSE VANE IMPELLER2900 (rpm)CURVE NO. ____________MARCH 2000

1

2

3

1

3

2

4

4

1J1-1/2X1US-6

1K1-1/2X1-1/2US-82

2K2X1-1/2US-10A

2K3X2US-10

2538A

0 35 70 105 140 200 250 300

100 200 300 400 500 600 800 1200

120

100

80

60

40

20

0

40

35

30

25

20

15

10

5

0

FLOW - 1450 rpm (50Hz) m3/h

FLOW - 1450 rpm (50Hz) US gpm

TDH

145

0 rp

m (5

0Hz)

m

TDH

145

0 rp

m (5

0Hz)

ft

Mark II & Mark IIICOMPOSITE PERFORMANCEREVERSE VANE IMPELLER1450 (rpm)CURVE NO. ____________MARCH 2000

1

2

3

4

5

6

SC

AL

EC

HA

NG

E

1

2 3

4

5

6 7

7

1K1-1/2X1-1/2US-82

2K2X1-1/2US-10A

2K3X2US-10

2K3X2US-13

2K4X3US-10H

2K4X3US-13

2K6X4US-13A

2539A

23

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 23

Page 24: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

24

1

0 5 10 15 20 25

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

1J1-1/2X1US-62900 (rpm)7061V

17.87 cm2

9.5 mmREVERSE VANESTD-N/A

DURCO Mark II

SPEED

CURVE NO.

20 40 60 80 100 120

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)8

4

0

(m)3

2

1

00 10 20 30

0 40 80 120

STUFF BOX HEADABOVE T.S.H. (ft)

(m)6

4

2

0

15

10

5

0

6in 5in

0 50 100 150PRIMING TIME SECONDS

VOLUME OF 40 mmSUCT. PIPE EQUALSSTATIC LIFT + 1mm

100

80

60

40

4

3

2

1

30

25

20

15

10 4

3

2

1

0

NPSH (m)

6 in Ø

5-1/2 in Ø

5 in Ø

40

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-29

US (gpm)

(m3/h)

20 30

4548

48

1

1.5

.5

2

2.5

3

EFF %

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 24

Page 25: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 10 20 30 40 50

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

1K1-1/2X1-1/2US-822900 (rpm)7261

20.8 cm2

8/7 mmREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

50 100 150 200 250

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)60

45

30

15

0

(m)15

10

5

00 20 40 60

0 50 100

STUFF BOX HEADABOVE T.S.H.

(ft)(m)6

4

2

0

20

15

10

5

0

8 3/16in 6in

0 20 40 60 80PRIMING TIME SECONDS

VOLUME OF 40 mmSUCT. PIPE EQUALSSTATIC LIFT + 1mm

200

150

100

50

15

10

5

80

60

40

20

0

10

5

0

7in

NPSH (m)

8-3/16 in Ø

7-1/2 in Ø

7 in Ø

6-1/2 in Ø

6 in Ø

4046

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D91-01-22

US (gpm)

(m3/h)

30

46

12

34

EFF %

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

25

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 25

Page 26: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 5 10 15 20 25

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

1K1-1/2X1-1/2US-821450 (rpm)7263

20.8 cm2

8/7 mmREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

20 40 60 80 100

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)15

10

5

0

(m)4

2

00 10 20 30

0 50 100

STUFF BOX HEADABOVE T.S.H.

(ft)(m)6

4

2

0

20

15

10

5

0

8 3/16in

0 30 60 90PRIMING TIME SECONDS

VOLUME OF 40 mmSUCT. PIPE EQUALSSTATIC LIFT + 1mm

60

50

40

30

20

10

4

3

2

1

20

15

10

5

0

3

2

1

0

NPSH (m)

8-3/16 in Ø

8 in Ø 40

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D91-01-23

US (gpm)

(m3/h)

30

4549

4045

491

1.5

.5

2

EFF %

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

26

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 26

Page 27: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

0 10 20 30 40 50

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K2X1-1/2US-10A2900 (rpm)8061V

22.65 cm2

9.5 mmREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

50 100 150 200 250

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)15

10

5

0

(m)6

4

2

00 20 40 60

0 100 200

STUFF BOX HEADABOVE T.S.H. (ft)

(m)6

4

2

0

15

10

5

0

8-10in

0 50 100 150 200PRIMING TIME SECONDS

VOLUME OF 50 mmSUCT. PIPE EQUALSSTATIC LIFT + 1mm

300

200

100

24

16

8

100

80

60

40

20 20

15

10

5

0

7in

NPSH (m)

10 in Ø

9-1/2 in Ø

9 in Ø

8-1/2 in Ø

8 in Ø

7-1/2 in Ø

7 in Ø

35

40

42

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

P(kW)

(m3/h)

(gpm)

Y-M-D82-01-29

US (gpm)

(m3/h)

2030

11.5 2

4

EFF %

3

27

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 27

Page 28: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

28

1

0 4 8 12 16 20

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K2X1-1/2US-10A1450 (rpm)8063V

22.65 cm2

10.32 mmREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

20 40 60 80 100

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)8

4

0

(m)3

2

1

00 5 10 15 20

0 20 40 60 80

STUFF BOX HEADABOVE T.S.H. (ft)

(m)6

4

2

0

15

10

5

0

8in

10in

0 50 100 150PRIMING TIME SECONDS

VOLUME OF 50 mmSUCT. PIPE EQUALSSTATIC LIFT + 1mm

80

60

40

20

4

3

2

1

24

20

16

12

8

43

2

1

0

9in

NPSH (m)

10 in Ø

9-1/2 in Ø

9 in Ø

8-1/2 in Ø

8 in Ø

35

40ST

ATIC

SUC

TION

-LIF

T

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-02

US (gpm)

(m3/h)

20

30

38

1

.75.5

EFF %

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 28

Page 29: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 20 40 60 80 100

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K3X2US-102900 (rpm)7861V

48.46 cm2

12.7 mmREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

100 200 300 400 500

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)15

10

5

0

(m)6

4

2

00 40 80 120

0 200 400

STUFF BOX HEADABOVE T.S.H.

(ft)

(m)6

4

2

0

15

10

5

0

8in10in

0 30 60 90PRIMING TIME SECONDS

VOLUME OF 80 mmSUCT. PIPE EQUALSSTATIC LIFT + 1mm

250

200

150

100

30

20

10

80

60

40

20

30

20

10

0

9in7in

NPSH (m)

10 in Ø

9-1/2 in Ø

9 in Ø

8-1/2 in Ø

8 in Ø

7-1/2 in Ø

7 in Ø

40

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-02

US (gpm)

(m3/h)

3050

55

50

55

1 23

4

6

5

EFF %

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

.5

29

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 29

Page 30: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 20 40 60 80 100

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K3X2US-101450 (rpm)7863V

48.46 cm2

12.7 mmREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

50 100 150 200 250 300 350 400 450 500

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

60

40

20

5

4

3

2

1

20

16

12

8

4 4

3

2

1

0

NPSH (m)

10 in Ø

9-1/2 in Ø

9 in Ø

8-1/2 in Ø

8 in Ø

40

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-03

30

5052

45

40

5052

45

1

1.5

2

3

.3.5

EFF %

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

(ft)4

2

0

(m)2

1

00 20 40 60 80

100 200 300

STUFF BOX HEADABOVE T.S.H. (ft)

(m)6

4

2

0

15

10

5

0

8in

0 50 100 150 200PRIMING TIME SECONDS

VOLUME OF 80 mmSUCT. PIPE EQUALSSTATIC LIFT + 1mm

9in10in

STAT

IC S

UCTI

ON-L

IFT

US (gpm)

(m3/h)

30

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 30

Page 31: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 20 40 60 80 100

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K3X2US-131450 (rpm)7461V

48.46 cm2

10.3mmREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

100 200 300 400 500

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

120

80

40

0

15

12

8

4

40

30

20

10

0

12

8

4

0

NPSH (m)

10 in Ø

13 in Ø

12-1/2 in Ø

12 in Ø

11-1/2 in Ø

11 in Ø

10-1/2 in Ø

40

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-03

50

45

49

40

45

1.5

23 4

65

EFF %

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

(ft)6

4

2

0

(m)2

1

00 20 40 60 80

100 200 300 0

STUFF BOX HEADABOVE T.S.H. (ft)

(m)6

4

2

0

15

10

5

0

10in

0 30 60 90 120PRIMING TIME SECONDS

VOLUME OF 80 mmSUCT. PIPE EQUALSSTATIC LIFT + 1mm

13in

STAT

IC S

UCTI

ON-L

IFT

US (gpm)

(m3/h)

12in 11in

31

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 31

Page 32: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

32

1

0 40 80 120 160 200

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K4X3US-10H1450 (rpm)7661V

85.18 cm2

19.8 mmREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

100 200 300 400 500 600 700 800 900

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

60

40

20

9

6

3

20

16

12

8

4

8

4

0

NPSH (m)

10 in Ø

9-1/2 in Ø

9 in Ø

8-1/2 in Ø

8 in Ø

64

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-09

60

30 50

64

60

11.5

.5

22.5

3

3.5

EFF %

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

(ft)4

2

0

(m)1.5

1.0

.5

00 40 80 120 160

200 400 600

STUFF BOX HEADABOVE T.S.H. (ft)

(m)6

4

2

0

15

10

5

0

8in

0 50 100 150 200PRIMING TIME SECONDS

VOLUME OF 100 mmSUCT. PIPE EQUALSSTATIC LIFT + 1mm

9in

10in

STAT

IC S

UCTI

ON-L

IFT

US (gpm)

(m3/h)

24

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 32

Page 33: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

33

0 40 80 120 160 200

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K4X3US-131450 (rpm)7561V

85.48 cm2

17.5 mmREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

200 400 600 800 1000

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

120

100

80

60

40

20

24

16

8

40

30

20

10

0 20

15

10

5

0

NPSH (m)

13 in Ø

12-1/2 in Ø

12 in Ø

11-1/2 in Ø

11 in Ø

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-09

60

3050 55

60

55

1.5

23 4

5

EFF %

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

(ft)8

4

0

(m)3

2

1

00 50 100 150 200

200 400 600 800

STUFF BOX HEADABOVE T.S.H. (ft)

(m)6

4

2

0

15

10

5

0

12in

0 60 120 180 240PRIMING TIME SECONDS

VOLUME OF 100 mmSUCT. PIPE EQUALSSTATIC LIFT + 1mm

13in

11in

STAT

IC S

UCTI

ON-L

IFT

US (gpm)

(m3/h)

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 33

Page 34: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 50 100 150 200 250

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K6X4US-13A1450 (rpm)8161V

187.1 cm2

26.2 mmREVERSE VANESTD-N/A

DURCO Mark III

SPEED

CURVE NO.

200 400 600 800 1000 1200

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

120

80

40

30

20

10

40

30

20

10

0

30

20

10

0

NPSH (m)

13 in Ø

12-1/2 in Ø

12 in Ø

11-1/2 in Ø

11 in Ø

69

65

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D82-01-10

6068

50

1 1.5 22.5

3

EFF %

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

(ft)4

2

0

(m)3

2

1

00 80 160 240 320

400 800 120

STUFF BOX HEADABOVE T.S.H. (ft)

(m)6

4

2

0

15

10

5

0

12in

0 60 120 180 240PRIMING TIME SECONDS

VOLUME OF 150 mmSUCT. PIPE EQUALSSTATIC LIFT + 1mm

13in

11in

STAT

IC S

UCTI

ON-L

IFT

US (gpm)

(m3/h)

1 VIBRATION AND NOISE EXCEEDS SPECIFIED LIMITS.

1

34

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 34

Page 35: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 50 100 150 200 250 300

10 20 30 40 50 60

120

100

80

60

40

20

0

800

700

600

500

400

300

200

100

0

FLOW - 3500 rpm (60Hz) m3/h

FLOW - 3500 rpm (60Hz) US gpm

TDH

350

0 rp

m (6

0Hz)

m

TDH

350

0 rp

m (6

0Hz)

ft

Mark IIICOMPOSITE PERFORMANCEOPEN VANE IMPELLER3500 (rpm)CURVE NO. ________APRIL 2000

1 2

1

2

1K1-1/2X1-1/2US-82

2KX1-1/2US-10A

4507

35

PUMP SPEED CURVE # PAGEComposite 3500 4507 35

Curves 1750 4505 361150 4504 36

1K1-1/2X1-1/2US-82 3500 MIII 7270 371750 MIII 7272 38

2K2X1-1/2US-10A 3500 MIII 8065V 391750 MIII 8067V 401150 MIII 8069V 41

2K3X2US-13 1750 MIII 7463V 421150 MIII 7465V 43

2K4X3US-10H 1750 MIII 7663V 441150 MIII 7665V 45

2K4X3US-13 1750 MIII 7563V 461150 MIII 7565V 47

2K6X4US-13A 1750 MIII 8163V 481150 MIII 8165V 49

PUMP SPEED CURVE # PAGEComposite 2900 4506 50

Curves 1450 4508 501K1-1/2-1/2US-82 2900 MIII 7271 51

1450 MIII 7273 522K2X1-1/2US-10A 2900 MIII 8066V 53

1450 MIII 8068V 542K3X2US-13 1450 MIII 7464V 55

2K4X3US-10H 1450 MIII 7664V 562K4X3US-13 1450 MIII 7564V 57

2K6X4US-13A 1450 MIII 8164V 58

Index-60 Cycle Open Vane Curves Index-50 Cycle Open Vane Curves

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 35

Page 36: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

36

0 400 800 1200 1600 2000 2400

50 100 150 200 250 300 350 400 450 500

90

80

70

60

50

40

30

20

10

0

320

280

240

200

160

120

80

40

0

FLOW - 1750 rpm (60Hz) m3/h

FLOW - 1750 rpm (60Hz) US gpm

TDH

175

0 rp

m (6

0Hz)

m

TDH

175

0 rp

m (6

0Hz)

ft

Mark IIICOMPOSITE PERFORMANCEOPEN VANE IMPELLER1750 (rpm)CURVE NO. ____________APRIL 2000

1

2

3

4

5

6

61

2

3

4

5

4505

1K1-1/2X1-1/2US-82

2K2X1-1/2US-10A

2K3X2US-13

2K4X3US-10H

2K4X3US-13

2K6X4US-13A

0 200 400 600 800 1000 1200

20 40 60 80 100 120

20

15

10

5

0

80

70

60

50

40

30

20

10

0

FLOW - 1150 rpm (60Hz) m3/h

FLOW - 1150 rpm (60Hz) US gpm

TDH

115

0 rp

m (6

0Hz)

m

TDH

115

0 rp

m (6

0Hz)

ft

Mark IIICOMPOSITE PERFORMANCEOPEN VANE IMPELLER1150 (rpm)CURVE NO. ____________APRIL 2000

1

2

3

4

5

1

2

3 4 5

4504

2K2X1-1/2US-10A

2K3X2US-13

2K4X3US-10H

2K4X3US-13

2K6X4US-13A

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 36

Page 37: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

37

2

0 50 100 150 200 250

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

1K1-1/2X1-1/2US-823500 (rpm)7270

3.7 in2

15/32 inOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

10 20 30 40 50 60

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft) 20

10

(m)

60

40

200 100 200 300

0 20 40

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

8 3/16in

5in

6in

0 20 40 60 80PRIMING TIME SECONDS

VOLUME OF 1.5inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

80

70

60

50

40

30

20

10

15

10

5

300

250

200

150

100

50

0

30

20

10

0

7in

8-3/16 in Ø

8 in Ø

7-1/2 in Ø

7 in Ø

6-1/2 in Ø

6 in Ø

5-1/2 in Ø

5 in Ø

35

1215

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft) P(kW)

(m3/h)

US (gpm)

Y-M-D91-01-20

US (gpm)

(m3/h)

30

38

36 8

EFF %

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 37

Page 38: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 25 50 75 100 125

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

1K1-1/2X1-1/2US-821750 (rpm)7272

3.7 in2

15/32 inOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

5 10 15 20 25 30

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft) 6

4

2

0

(m)

16

8

00 50 100 150

0 10 20 30

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

4

2

0

8 3/16in

6in

0 30 60 90PRIMING TIME SECONDS

VOLUME OF 1.5inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

250

20

15

10

5

2

1

100

75

50

25

0

3

2

1

0

7in

8-3/16 in Ø

7-1/2 in Ø

7 in Ø

6-1/2 in Ø

6 in Ø

35

10

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D91-01-20

US (gpm)

(m3/h)

2030

35

30

2 4 6 8

EFF %

38

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 38

Page 39: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 50 100 150 200 250

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K2X1-1/2US-10A3500 (rpm)8065V

4.1 in2

5/16 inOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

15 30 45 60

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

8

6

4

2

0

(m)30

20

10

00 100 200 300

0 20 40 60

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

5

4

3

2

1

0

8,9&10in

5in

6in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 2inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

150

100

50

50

25

500

400

300

200

100

0 75

50

25

0

7in

10 in Ø

9 in Ø

8 in Ø

7 in Ø

6 in Ø

5 in Ø

1014

18

32

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D94-04-20

US (gpm)

(m3/h)

36

20

6

EFF %

39

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 39

Page 40: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

40

0 40 80 120 160 200

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(ft)

2K2X1-1/2US-10A1750 (rpm)8067V

4.1 in2

5/16 inOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

10 20 30 40 50

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

30

20

10

8

4

100

80

60

40

20 12

8

4

0

P(kW)

TDH(m)

P(hp)

(m3/h)

US (gpm)

Y-M-D94-04-20

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

120

NPSH (ft)

10 in Ø

9 in Ø

8 in Ø

7 in Ø

20

30

34 6

5

EFF %

(ft)

2

1

0

(m)8

4

00 50 100 150

0 10 20 30

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

5

4

3

2

1

0

8in9in10in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 2inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

7in

STAT

IC S

UCTI

ON-L

IFT

US (gpm)

(m3/h)

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 40

Page 41: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

41

2

0 25 50 75 100 125

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K2X1-1/2US-10A1150 (rpm)8069V

4.1 in2

5/16 inOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

10 20 30

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

1.0

.5

0

(m)4

2

00 25 50 75

0 5 10 15

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

5

4

3

2

1

0

9in

10in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 2inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

15

10

5

1

0.5

50

40

30

20

10

0 3

2

1

0

10 in Ø

9 in Ø

23

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D94-04-20

US (gpm)

(m3/h)

20

10

20

1

2

EFF %

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 41

Page 42: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 100 200 300 400 500

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K3X2US-131750 (rpm)7463V

7.9 in2

13/32 inOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

40 80 120

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

60

40

20

20

10

160

120

80

40

0 30

20

10

0

P(kW)

TDH(ft)

P(hp)

(m3/h)

US (gpm)

Y-M-D94-08-21

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

200

(ft)3

2

1

0

(m)10

5

00 200 400 500

0 50 100

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

5

4

3

2

1

0

12in

9in10in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 40 mmSUCT. PIPE EQUALSSTATIC LIFT + 1mm

13in

11in

NPSH (ft)

10 in Ø

9 in Ø

11 in Ø

12 in Ø

13 in Ø

35

10

STAT

IC S

UCTI

ON-L

IFT

US (gpm)

(m3/h)

50

45

45

46

8

EFF %

42

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 42

Page 43: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 50 100 150 200 250

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K3X2US-131150 (rpm)7465V

7.9 in2

13/32 inOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

15 30 45 60

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

1.0

.5

0

(m)4

2

00 100 200 300

0 20 40 60

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

5

4

3

2

1

0

12in

9in

10in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 3inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

30

20

10

8

4

100

80

60

40

20

0 12

8

4

0

11in

10 in Ø

11 in Ø

12 in Ø

13 in Ø

35

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D94-08-21

US (gpm)

(m3/h)

45

47

2

4

EFF %

13in

43

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 43

Page 44: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

44

0 200 400 600 800 1000

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K4X3US-10H1750 (rpm)7663V

10.3 in2

11/16 inOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

50 100 150 200 250

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

4

2

0

(m)16

8

00 400 800 1200

0 50 100

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

5

4

3

2

1

0

9&8in

10in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 4inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

30

20

10

20

10

100

80

60

40

20

0 30

20

10

0

7in

10 in Ø

9 in Ø

8 in Ø

7 in Ø

40

10

1412

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)P

(kW)

(m3/h)

US (gpm)

Y-M-D94-04-20

US (gpm)

(m3/h)

50 60

63

50

60

63

46 8

EFF %

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 44

Page 45: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

45

2

0 100 200 300 400 500

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K4X3US-10H1150 (rpm)7665V

10.3 in2

11/16 inOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

40 80 120

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

1.5

1.0

.5

0

(m)6

4

2

00 200 400 600

0 50 100

STUFF BOX HEADABOVE T.S.H.

(ft)

(m)15

10

5

0

4

3

2

1

0

9in

10in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 4inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

15

10

5

4

2

50

40

30

20

10

0 6

4

2

0

10 in Ø

9 in Ø

40

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D94-04-20

US (gpm)

(m3/h)

50

56

59

50

56

6

5

7

8

EFF %

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 45

Page 46: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 200 400 600 800 1000

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(ft)

2K4X3US-131750 (rpm)7563V

12.5 in2

11/16 inOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

50 100 150 200 250

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

60

40

20

40

20

160

120

80

40

0 60

40

20

0

P(kW)

TDH(m)

P(hp)

(m3/h)

US (gpm)

Y-M-D94-08-21

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

200

(ft)

15

10

5

0

(m)16

0

-160 400 800 1200

0 20 40 60

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

5

4

3

2

1

0

13in

9in

10&11in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 4inSUCT. PIPE EQUALSSTATIC LIFT + 3ft

12in

NPSH (ft)

10 in Ø

9 in Ø

11 in Ø

12 in Ø

13 in Ø40

1013

STAT

IC S

UCTI

ON-L

IFT

US (gpm)

(m3/h)

50

6550

60

4 68

EFF %

46

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 46

Page 47: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 100 200 300 400 500

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K4X3US-131150 (rpm)7565V

12.5 in2

11/16 inOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

30 60 90 120

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

15

10

5

0

(m)6

0

-60 300 600 900

0 20 40 60

STUFF BOX HEADABOVE T.S.H.

(ft) (m)20

15

10

5

0

6

5

4

3

2

1

0

12in

13in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 4inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

30

20

10

10

5

100

80

60

40

20

0 15

10

5

0

12 in Ø

13 in Ø40

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D94-08-22

US (gpm)

(m3/h)

60

50

60

50

46

8

EFF %

47

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 47

Page 48: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

48

0 500 1000 1500 2000 2500

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K6X4US-13A1750 (rpm)8163V

29.1 in2

1 inOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

150 300 450 600

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

6

4

2

0

(m)20

10

00 1000 2000 3000

0 200 400 600

STUFF BOX HEADABOVE T.S.H.

(ft)

(m)20

15

10

5

0

6

5

4

3

2

1

0

13in

9in

10in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 6inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

60

40

20

50

25

200

150

100

50

0

-50 75

50

25

0

11in

10 in Ø

9 in Ø

13 in Ø

12 in Ø

11 in Ø

40 60

12

16

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D94-06-22

US (gpm)

(m3/h)

7070

6

8

EFF %

12in

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 48

Page 49: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

49

0 250 500 750 1000 1250

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K6X4US-13A1150 (rpm)8165V

29.1 in2

1 inOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

100 200 300

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)3

2

1

0

(m)10

5

00 500 1000 1500

0 100 200 300

STUFF BOX HEADABOVE T.S.H.

(ft)

(m)15

10

5

0

4

3

2

1

0

13in

11in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 6inSUCT. PIPE EQUALSSTATIC LIFT X 3ft

30

20

10

20

10

100

80

60

40

20

0 30

20

10

0

12in

11 in Ø

12 in Ø

13 in Ø

70

40

10

67

TO CALCULATE EXACTEFFICIENCY USE THE FOLLOWING

% EFF= TDH X GPM X 100 HP X 3960

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

NPSH (ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D94-06-22

US (gpm)

(m3/h)

60

70

50

67

2.5 46

8

EFF %

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 49

Page 50: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

50

0 5 10 15 20 25 30

50 100 150 200

300

250

200

150

100

50

0

80

70

60

50

40

30

20

10

0

FLOW - 2900 rpm (50Hz) m3/h

FLOW - 2900 rpm (50Hz) US gpm

TDH

290

0 rp

m (5

0Hz)

m

TDH

290

0 rp

m (5

0Hz)

ft

Mark II & Mark IIICOMPOSITE PERFORMANCEOPEN VANE IMPELLER2900 (rpm)CURVE NO. ____________APRIL 2000

1

2

1 2

4506

1K1-1/2X1-1/2US-82

2K2X1-1/2US-10A

0 60 120 180 240 300 240

200 400 600 800 1000 1200 1400

120

100

80

60

40

20

0

40

35

30

25

20

15

10

5

0

FLOW - 1450 rpm (50Hz) m3/h

FLOW - 1450 rpm (50Hz) US gpm

TDH

145

0 rp

m (5

0Hz)

m

TDH

145

0 rp

m (5

0Hz)

ft

Mark II & Mark IIICOMPOSITE PERFORMANCEOPEN VANE IMPELLER1450 (rpm)CURVE NO. ____________APRIL 2000

1

2

3

4

5

1

2

3

4

5

1K1-1/2X1-1/2US-82

2K2X1-1/2US-10A

2K3X2US-13

2K4X3US-10H

2K4X3US-13

2K6X4US-13A

4508

6

6

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 50

Page 51: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

51

0 10 20 30 40 50

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

1K1-1/2X1-1/2US-822900 (rpm)7271

23.8 cm2

11/9 mmOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

50 100 150 200 250

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)45

30

15

0

(m)10

5

00 20 40 60

0 50 100

STUFF BOX HEADABOVE T.S.H.

200

150

100

50

15

10

5

80

60

40

20

0

10

5

0

NPSH (m)

8-3/16 in Ø

7-1/2 in Ø

7 in Ø

6-1/2 in Ø

6 in Ø

35

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D91-01-16

US (gpm)

(m3/h)

30

38

38

12 3

4

EFF %

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

(ft)(m)6

4

2

0

20

15

10

5

0

8 3/16in 6in

0 20 40 60 80PRIMING TIME SECONDS

VOLUME OF 40 mmSUCT. PIPE EQUALSSTATIC LIFT + 1mm

7in

STAT

IC S

UCTI

ON-L

IFT

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 51

Page 52: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 5 10 15 20 25

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

1K1-1/2X1-1/2US-821450 (rpm)7273

23.8 cm2

11/9 mmOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

20 40 60 80 100

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)15

10

5

0

(m)4

2

00 10 20 30

0 50 100

STUFF BOX HEADABOVE T.S.H.

60

50

40

30

20

10

4

3

2

1

20

15

10

5

0

3

2

1

0

NPSH (m)

8-3/16 in Ø

8 in Ø

37

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D91-01-16

US (gpm)

(m3/h)

2030

30

11.5

.5

22.5

EFF %

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

(ft)(m)6

4

2

0

20

15

10

5

0

8in

0 30 60 90 120PRIMING TIME SECONDS

VOLUME OF 40 mmSUCT. PIPE EQUALSSTATIC LIFT + 1mm

8 3/16in

STAT

IC S

UCTI

ON-L

IFT

37

52

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 52

Page 53: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 10 20 30 40 50

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K2X1-1/2US-10A2900 (rpm)8066V

26.5 cm2

7/9 mmOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

50 100 150 200 250

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

300

200

100

40

20

100

80

60

40

20

0 30

20

10

0

NPSH (m)

10 in Ø

9 in Ø

8 in Ø

7 in Ø33

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D94-04-16

20

32

12

34

EFF %

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

(ft)(m)6

4

2

0

20

15

10

5

0

8in,9in &10in

0 30 60 90 120PRIMING TIME SECONDS

VOLUME OF 2inSUCT. PIPE EQUALSSTATIC LIFT + 3ft

7in

STAT

IC S

UCTI

ON-L

IFT

(ft)15

10

5

0

(m)6

4

2

00 20 40 60

0 100 200

STUFF BOX HEADABOVE T.S.H.

US (gpm)

(m3/h)

53

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 53

Page 54: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

54

0 5 10 15 20 25

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K2X1-1/2US-10A1450 (rpm)8068V

26.5 cm2

7/9 mmOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

25 50 75 100 125

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

80

60

40

20

4

2

25

20

15

10

5

0

NPSH (m)

10 in Ø

9 in Ø

8 in Ø

27

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D94-04-16

20

1

.5

EFF %

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

(ft)(m)6

4

2

0

20

15

10

5

0

8in

0 30 60 90 120 150PRIMING TIME SECONDS

VOLUME OF 2 inSUCT. PIPE EQUALSSTATIC LIFT + 3 ft

9in10in

STAT

IC S

UCTI

ON-L

IFT(ft)

8

4

0

(m)3

2

1

00 5 10 15 20

0 20 40 60 80

STUFF BOX HEADABOVE T.S.H.

US (gpm)

(m3/h)

3

2

1

0

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 54

Page 55: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

55

0 20 40 60 80 100

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K3X2US-131450 (rpm)7464V

51 cm2

10.3 mmOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

100 200 300 400 500

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

125

100

75

50

25

16

8

32

24

16

8

0 12

8

4

0

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D94-08-16

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

(ft)4

2

0

(m)1.5

1.0

.5

00 40 80 120 160

200 400 600

STUFF BOX HEADABOVE T.S.H.

US (gpm)

(m3/h)

40

(ft)

(m)6

4

2

0

15

10

5

0

11&10in

13in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 3 inSUCT. PIPE EQUALSSTATIC LIFT + 3 ft

9in

12in

NPSH (m)

10 in Ø

9 in Ø

11 in Ø

12 in Ø

13 in Ø

35

STAT

IC S

UCTI

ON-L

IFT

50

45

45

1 2

EFF %

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 55

Page 56: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 25 50 75 100 125

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K4X3US-10H1450 (rpm)7664V

66.5 cm2

17/5 mmOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

125 250 375 500 625

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)

(m)6

4

2

0

15

10

0

0

8in

0 60 120 180PRIMING TIME SECONDS

VOLUM OF 4 inSUCT. PIPE EQUALSSTATIC LIFT + 3 ft

80

60

40

20

20

10

25

20

15

10

5

0 15

10

5

0

9in

10in

NPSH (m)

10 in Ø

9 in Ø

8 in Ø

40

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D94-04-16

50 57

61

61

57

5011.5

22.5

EFF %

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

(ft)4

2

0

(m)1.5

1.0

.5

00 40 80 120 160

200 400 600

STUFF BOX HEADABOVE T.S.H.

US (gpm)

(m3/h)

56

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 56

Page 57: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

57

0 40 80 120 160 200

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K4X3US-131450 (rpm)7564V

80.6 cm2

17.5 mmOPENSTD-N/A

DURCO Mark III

SPEED

CURVE NO.

200 400 600 800 1000

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

120

80

40

32

16

32

24

16

8

0 24

16

8

0

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D94-08-16

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

40

(ft)

(m)6

4

2

0

15

10

5

0

12in & 11in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 4inSUCT. PIPE EQUALSSTATIC LIFT + 3ft

13in

NPSH (m)

64

STAT

IC S

UCTI

ON-L

IFT

50

60

50

60

1

1.5

2

EFF %

13 in Ø

12 in Ø

11 in Ø

(ft)8

4

0

(m)3

2

1

00 50 100 150 200

200 400 600 800

STUFF BOX HEADABOVE T.S.H.

US (gpm)

(m3/h)

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 57

Page 58: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

0 50 100 150 200 250

EYE AREA

MAX SPHERE

IMPELLERPUMP PERFORMANCECHARACTERISTICS

TDH(m)

2K6X4US-13A1450 (rpm)8164V

187.8 cm2

25.4 mmOPENSTD-A80

DURCO Mark III

SPEED

CURVE NO.

250 500 750 1000 1250

CONSULT YOUR FLOWSERVE REPRESENTATIVE FOR MINIMUM FLOW CONSIDERATION

(ft)(m)6

4

2

0

20

15

10

5

0

13in

10in

11in

0 60 120 180PRIMING TIME SECONDS

VOLUME OF 6inSUCT. PIPE EQUALSSTATIC LIFT + 3ft

160

120

80

40

40

20

50

40

30

20

10

0 30

20

10

0

12in

NPSH (m)

10 in Ø

11 in Ø

12 in Ø

13 in Ø 40 60

STAT

IC S

UCTI

ON-L

IFT

P(hp)

TDH(ft)

P(kW)

(m3/h)

US (gpm)

Y-M-D94-06-16

5070

70

1 1.5 2 2.5

3

EFF %

TO CALCULATE EXACTEFFICIENCY USE METRIC UNITS

WITH SPECIFIC GRAVITY=1.0IN THE FOLLOWING EQUATION

% EFF = TDH X CAPACITY

X 100kW X 369

(ft)4

2

0

(m)3

2

1

00 80 160 240 320

400 800 120

STUFF BOX HEADABOVE T.S.H.

US (gpm)

(m3/h)

58

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 58

Page 59: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 59

Page 60: Curvas Caracteristicas de Las Bombas Durco Mark III

© TriCom, Inc., 2005, All Rights Reserved.

To find your local Flowserve representative please use the Sales Support Locator System

found at www.flowserve.com

Or call toll free: 1 800 728 PUMP (7867)

Your local Flowserve representative:

USA and CanadaFlowserve CorporationPump Division5215 North O’Connor Blvd.Suite 2300Irving, Texas 75039-5421 USATelephone: 1 972 443 6500Telefax: 1 972 443 6800

Europe, Middle East, AfricaFlowserve CorporationPump DivisionVia Rossini 90/9220033 Desio (Milan), ItalyTelephone: 39 0362 6121Telefax: 39 0362 303396

Latin America and CaribbeanFlowserve CorporationPump Division6840 Wynnwood LaneHouston, Texas 77008 USATelephone: 1 713 803 4434Telefax: 1 713 803 4497

Asia Pacific Flowserve Pte. Ltd.Pump Division 200 Pandan Loop #06-03/04Pantech 21Singapore 128388Telephone: 65 6775 3003Telefax: 65 6779 4607

Flowserve... Supporting Our CustomersWith The World’s LeadingPump Brands

Jeumont-Schneider™Jeumont-Schneider™

Printed in U.S.A.April 2005

© Flowserve Corporation

(P-12-102) CurveBk_1Up 5/12/05 8:55 AM Page 60