ProSoft Technology Company Overview

HQ in Bakersfield, CA Founded by Doug Sharratt First products in 1988 Manufacturing in Mooresville, NC

Global Organization Over 110 employees worldwide

Strong application experience Industrial Communication Wireless Communication

3 Year WarrantyBest in class tech support – No Charge

8:00 – 8:00 EST

Communication Solutions

ProSoft Technology® specializes in the development of communication solutions compatible with the large automation suppliers' controllers.

The primary focus is to provide connectivity solutions that link automation products.

IN-CHASSISWIRELESSGATEWAYS

In‐Chassis Product update

MVI56E-LDMADM / ADMNET replacementLinux Development module

MVI69E-LDMADM / ADMNET replacementLinux Development module

ILX34 Modbus

ProSoft Serial Modbus Master / Slave communications module that resides in a distributed Point I/O system or in the backplane of the CompactLogix® L1 Controller.

5

RS485 Master Architecture

Modbus PowerFlex4M

CompactLogix L1 Controller

6

ILX34-MBS485

RS232 Slave Architecture

HMI, SCADA, or DCS

Modbus

7

ILX34-MBS232

CompactLogix L1 Controller

Connect Control System to Building Automation Devices/Systems

HVAC ControlsChillers, VAV, boilers, etc

Power generatorsLighting controlsFire alarm panelsEnergy systems

EtherNet/IP to Modbus Serial(4)

PLX31-EIP-MBS

PLX31-EIP-MBS4

EtherNet/IP to Modbus TCP/IP

PLX31-EIP-MBTCP

EtherNet/IP to ASCII

PLX31-EIP-ASCII

PLX31-EIP-ASCII4

Modbus TCP/IP to Modbus Serial(4)

PLX31-MBTCP-MBS

PLX31-MBTCP-MBS4

ProLinx Gateways

PLX32‐EIP‐MBTCP

2- EtherNet Ports2- EtherNet Boards2- Separate EtherNet Sub-nets

PROFINET

ProfiNET Device

11

12

PROFINET

ProfiNET I/O Controller

ProfiNET Devices

ProfiNET

EtherNet I/P

Integrated Liquid & Gas Flow Computing

MVIXX-AFC

Powerful flow computer module, augmenting Logix system by providing a dedicated and accurate set of flow calculations.Supports 16 meter runs, measuring hydrocarbon gases and liquids using currently accepted industry measurement standardsCalculation results are transferred to processor memory and may also be transferred to a SCADA host using Modbus.User configurable, allowing each of the meter runs to be individually set up to meet the specific requirements of an application

13

Process Inputs

The Input Values read by the module may be viewed in the meter monitor window. Calibration feature ignores changes in the process input variables.

14

Temp Temp

1756-IF8 CLX MVI56-AFC

Pressure Pressure

DP DP

Flow Rate

Volume

AFC Manager

Configuration and Monitoring software for AFC module

AFC Manager ‐ Archives

Hourly for two days and daily for one month Optional extended archives up to 1,440 hours (60 days) and 1,440 dailyLadder logic - batch control command

MultiVariable Flow Meters

Combines Differential Pressure, Static Pressure, and Process Temperature measurements along with Mass and Energy Flow in a single deviceCoriolis flow computer - oil

17

Wireless and Cellular

900 MHz and 2.4 GHz Industrial Frequency Hopping Ethernet

RF Power

Frequency

Frequency Hopping Waveform

RLX2 Family

RLX2-IHA RLX2-IHG

RLX2-IHW RLX2-IHNF

Applying Wireless to EtherNet/IP Automation Systems

Communication to moving/spinning equipment No mechanical wear/tear No cable to break (plugging/unplugging) Reduces production downtime Alternative to slip rings, festooning, rails, etc.

Automatic Guided Vehicle Overhead Crane Conveyor System

Festoon System Slip Ring

Machine Mobility

Rotary Commutater Replacement

This plant has a filler that fills 16 bottles at a time with laundry detergent, liquid soap or other products.PLC Processor talking with 16 Remote I/O Blocks

5GHz – Data VLAN

FeaturesReliable I/O MessagingE/IP RPI times to 2msDual Radio – 2.4/5 GHzVLAN for Mobile WorkerRADIUS Security

2.4G

Hz

–IT

VLA

N

ProSoft Technology Confidential ‐ For Internal Use Only23

Packaging & Bottling

Station Station Station Station

Station Station Station Station

Automated Vehicles

24

Vehicles move sub-assemblies from station to stationMobile workstations allow network access

Finished Units

Raw Materials

Mobile Workstation

Mobile Workstation

Mobile Workstation

Back Haul for Field Transmitters

Worker Mobility

Information & control available anywhere Wireless plant networks for:

– Production workers– Managers– Maintenance

Data collection Alarming Remote access for programming/diagnostics

ProSoft  Wireless Tools

Run Designer

Micro800 SMS Plug‐in

Plug-in module for Micro830 PLCCommunicates directly to processor

Industrial Cellular M2M Gateway

ICX30-HWCWhat is it? What does it do?

The ICX30 is an industrial grade cellular modem that communicates to devices on its serial and or Ethernet port. It also communicate to the cellular network (tower) where this information is accessible through remote users or the internet.

PRELIMINARY & CONFIDENTIAL – Internal Use Only

Huge install base of Allen Bradley Remote I/O Systems

Problem

Most of the products pictured above are either Silver Series or Discontinued

Phased Solution

RA Migration Remote I/O

32

Opportunity: My old Panelviews are failing and I need to start migrating, but I need a solution that I can re-use later after additional upgrades have been made, and I can’t get Remote I/O cards anymore…..

Blue Hose

AB Remote I/O

PLC5PanelView Classic

AN-X2-AB-DHRIOEtherNet/IP

PanelView Plus 6

RA Migration Remote I/O

33

Opportunity: Existing 1305 and 1336 drives on Remote I/O are failing. How can these be replaced with new drives, without the need to alter the PLC programs since minimal downtime is available?

AN-X2-AB-DHRIOBlue Hose

AB Remote I/O

EtherNet/IP

PLC5

PowerFlex Drive1336 Drive

Phased Migration Solution

34

Select to play

Phased Solution

35

Sample Phased Migration

1300’ RIO network

Copyright ©2013 ProSoft Technology, Inc. All rights Reserved.

Prosoft Training 

This section provides video and other multimedia training that you can instantly view online, or download and watch at your leisure.

In-Chassis Solutions for Rockwell AutomationILX56-MM Initial Setup VideoCIPconnect Introduction VideoMVI56-MCM Add On Instruction VideoMVI56-PDPMV1 PROFIBUS DPV1 Setup TutorialMVI69-MCM Modbus Setup TutorialMVI56E-MCM mini Tutorial - NEW

Stand-alone Gateway & Wireless GatewaysModbus TCP/IP to PROFIBUS DPV1 Master for SE M340 PAC

Wireless SolutionsRLX-IH - Quick SetupRLX-PWD ProSoft Wireless Designer Quick SetupDesign a high-speed wireless network and complete BOM in under a minute.. WHAT!?! - NEW

Who to Contact?Ken Majerus – 630‐258‐1843kmajerus@prosoft‐technology.com

ProSoft Technology Inc.5201 Truxtun Ave, 3rd FloorBakersfield, CA 93309Tel: +1 661‐716‐5100Fax: +1 661‐716‐5101Email: prosoft@prosoft‐technology.com Website:  www.prosoft‐technology.com 

Technical Support DepartmentEmail: support@prosoft‐technology.com 

Order Entry / Shipping / Pricing and AvailabilityEmail: sales@prosoft‐technology.com 

Product ReturnsEmail: rma@prosoft‐technology.com

Technical Center‐Wireless5540 Research Park Drive Madison, WI 53711 Tel: +1 608‐275‐1023 

Thank you

Ken Majerus