Company Presentation January 2011. Noliac Group Technology, Products and Applications. Noliac is specialized in a high degree of customization. Piezoelectric Actuator Drive -PAD. PAD – Piezoelectric Actuator Drive Developed by Siemens 2000 - 2008 A partner needed for commercialisation - PowerPoint PPT PresentationTRANSCRIPT
Company PresentationJanuary 2011
Noliac Group Technology, Products and Applications
Noliac is specialized in a high degree of customization
• PAD – Piezoelectric Actuator Drive• Developed by Siemens 2000 - 2008• A partner needed for commercialisation• Noliac A/S acquired the PAD technology
from Siemens AG in 2010– Patents– Fully equipped test laboratories– PAD prototypes and demonstrators– Training of engineers
• Motor currently being developed for Siemens
Piezoelectric Actuator Drive -PAD
The displacement is generated by the piezo components
– Signals with 90° phase
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0 90 180 270 360
Rela
tive
ampl
itude
Angle (degrees)
Piezoelectric Actuator Drive -PAD
Servo-controlled System
PAD electronics
PAD motion control
PAD drive
CAN, Profi-Bus, ...... Gearbox
Position sensor
Torque sensor
E-Motor
Motion control
E-Brake
Electronics
CAN, Profi-Bus, ......
PAD System
PAD – Reduced Complexity
PAD - Characteristics
Dynamics High acceleration and deceleration without e-brake (low inertia) Slow and precise motion possible (0 to 60 rpm) Revolution independent of load
Scalability Scalability in terms of power, relative speed and torque Synchronization of multiple PADs possible
Torque / load sensing
Smart load sensing without torque sensors High torque without gearbox / no backlash (typ. 6,5 Nm) Overload protection
Others No power consumption when holding a load Function not affected by strong magnetic fields or radiation No magnetic stray fields
Precision
Positioning accuracy and repeatability (< 2 arcseconds) without encoders/decoders
No gearbox required / no backlash No overshooting
Special conditions of relevance in relation to ITER:• High temperature (up to200°C) : High temperature is generally not a problem. Both the housing
and the actuators should be able to cope with high temperature, and the wiring can be insulated.
• Vacuum: PAD should be capable of withstanding Ultra High Vacuum (UHV) up to 10^3 Pa.
• Magnetic field: PAD has so far been successfully tested at 1,5T, but should be able to cope with a stronger magnetic field (5-8T).
• Radiations: Generally not a problem. The resistance will depend on the materials selected for the PAD unit.